Compliance Inspections -Attachment 11 - DOT Compliance Quality Assurance Auditing Procedure
|
|
- Dustin Norman
- 6 years ago
- Views:
Transcription
1 Compliance Inspections -Attachment 11 - DOT Compliance Quality Assurance Auditing Procedure
2 7-. DOT COMPLIANCE QUALITY ASSURANCE AUDITING PROCE..._ Attachment 1 I TABLE OF CONTENTS GENERAL FILES PROCEDURE TAB A Emergency Plans... Page 1 Training... ge 1 Liaison with Public Officials... Page 1 Public Apprisement... Page 1 Aerial Pipeline Patrol... Page 2 Damage Prevention Program... Pag e 2 Leakage Surveys with Gas Detector... Page 3.. Odonzatmn... Page 3 Relief Valves: Capacity Calculations... Pag e 4 Corrosion Control: Rectifiers, Critical Bonds. and Coupons... Page 4 LINE SPECIFIC FILES PROCEDURE TABB Overpressure Protection: Mainline... Pag e 1 Mainline Relief Valves... Page 1 Mainline Regulators... Page 1 Valves... Page 2 Patrolling: (Also visual leakage survey)... Page 3 Leaks, Damages and Failures... ge 4 Measurement: Relief Valves & Regulators... Page 5 Corrosion Control: Annual Survey, Bell-Holes, Shorted Casings. Page 5 CORROSION SURVEY CODES AND U L LIMITS TAB C.. Upperhwer Linuts... Page 1 Annual Survey Codes...Pag e 2 AUDIT FORMS TAB D General Files Check List (Form: CS )... Page 1-3 Individual Pipeline Files Check List (Form: CS )... Page 1-3 Facility Audit Results (Form: CS9pO040)... Page 1-2 TOC. Pipeline Revised: 24/99
3 d General Files Procedure Page 1 A S S T J R AT-PROCEQUBE ~ -Pians ( O&M S~C. 501) A. Training At least once each calendar year? Documentation reflects that employees are knowledgeable of procedures and have demonstrated that the training is effwtive? In an actual or simulated emergency, employees responses were reviewed to determine if the procedures were effectively followed? Was training participative classroom instruction or an actual emergency simulation? B. Liaison with public emergency services: 1. Liaison activities are performed at least once each calendar year, and include all emergency services that may be expected to respond? 2. The type of emergencies and plans for mutual assistance were discussed? 3. Protection of life and property were stressed? C. Public apprisement: (Recognizing a PL emergency) 1. Documentation of visits and appropriate literature mail-outs or handouts to: a) Public emergency organizations? b) Public officials? c) d) Landowners and residents near our pipelines? Excavation - related personnel actually working in vicinity of our pipelines? 2. Group meetings attended by: Tab 2-A -Pipeline General Files Revised: 2/4/99
4 " -." General Files Procedure a) Public officials? b) Public emergency personnel? c) Excavators and Contractors? d) Customers (distribution companies, etc...)? e) Company personnel? Page 2 In which the recognition and reporting of gas pipeline emergencies is a topic of discussion? 3. Public apprisement program is conducted: a) b) On a continuing basis? (ads, landowners, public) In conjunction with liaison activities annually?... c) By group meetings annually? : - ( O&M S~C ) A. B. C. D. Are all pipelines within the P/L District patrolled by air? Ifnot, should they be? What are the patrol fi-equencies? Are indications of leaks, construction activity, and other factors Setting the safety and operation of the pipelines quickly related to operations personnel? E. Are conditions such as soil erosion, exposed buried lines, damaged or missing line markers, etc., which could lead to a hazardous condition related to operations personnel in a timely manner? F. Are responses and actions of operations personnel adequate, timely and documented? PP : m ~ ( O&M S~C. 503) (for Class 3 locations with 46 or more buildings and all Class 4 locations) A. Does the program provide or generate sufficient documentation of A current list of excavators? Periodic (annual) notification of those excavators? Tab 2-A - Pipeline G end Files Revised: 2/4/99
5 General Files Procedure Page Periodic notification of the public in the vicinity of our pipeline(s)? Methods, content and fkquency of notifications to excavators and the public? B. C. Does the content of notifications include information on learning the location of our pipelinds)? Is a log of planned excavation notifications maintained and does it reflect Actual notifications to excavators that we have pipelines in the area? Type and identity of temporary location markers placed prior to excavation? D. E. Was onsite inspection provided for critical phases of construction in which the pipeline or coating could be damaged? In the case of blasting, was a leakage survey performed, if warranted, following the blasting? 1. Visual? 2. Gas detector? : * ( O M Sa ) A. If required odorant levels verified at the same frequencies listed below or more often, is a leakage survey with a gas detector performed? 1. In Class 3 locations, at intervals not exceeding months, but at least twice each calendar year? 2. In Class 4 locations, at intervals not exceeding 4 1/2 months, but at least four times each calendar year? B. Are shorted casings surveys with gas detectors conducted: 1. In Class 1 and 2 locations, at intervals not exceeding months, but at least twice each calendar year? 2. In Class 3 and 4 location, at intervals not exceeding months, but at least four times each calendar year?.. ( O&M Sec ) A. Odorization of gas in Class 3 and 4 locations 1. The combustible gas contains a natural odorant so that in a concentration in air of Tab 2-A - Pipeline General Files Revised: 2/4/99
6 - _. General Files Procedure Page 4 1/5 of the lower explosive limit, the gas is readily detectable by a person with a normal sense of smell a) Verified at intervals of no more than 7 1/2 months and at least twice each calendar year in Class 3 locations; and, at intervals of no more than 4 1/2 months and at least four times each calendar year in Class 4 locations? and b) Uses an odorometer? 2. Leakage suryeys are performed with gas detector - see Leakage Survey Section of auditing procedure. B. Ifodorant is introduced into the gas stream, it must: 1. Not be harmfid or toxic to persons breathing the gas, or 2. Harmfid or corrosive to material and equipment, and 3. Not be soluble in water to an extent greater than 2.5 parts to 100 parts by weight, and 4. Be introduced at levels without wide variations ( & O&M S~C ) A. Capacity calculations are made andlor reviewed at intervals not exceeding 15 months, but at least once each calendar year? B. Relief capacity is suf icient to prevent overpressuring of pipeline(s)? - See Survey Codes and Limits Sheets ( thru O&M Sec ) A. Rectifiers and associated equipment 1. Are rectifier readings obtained and other power sources and associated equipment electrically checked and inspected at least six times each year at no more than 2 1/2 month intervak? 2. Are deficiencies corrected before the next inspection date? 3. Are problems and corrective measures documented or indicated? B. Critical interference bonds - (where failure of the bond jeopardizes structure protection) 1. Are the bonds checked at least six times per year and within intervals of no more Tab 2-A -Pipeline Gend Files Revised: 2/4/99
7 * General Files Procedure Page 5 1. than 2 1/2 months? 2. Are problems and comctive measures documented or indicated? C. Internal coupons 1. Is corrosive gas being transported? if so, a) Has the effect of the gas on the pipeline been investigated? and, b) What steps have been taken to minimize the intemal corrosion? 1) Corrosion inhibitor? 2) Dehydration? 2. Have internal coupons been installed to monitor the effectiveness of the corrosion-mitigating program? If so, 3. Are the coupons checked two times each calendar year at intervals not exceeding 7 1/2 months? and 4. Is the mil loss per year acceptable? Tab 2-A - Pipeline General Files Revised: 2/4/99
8 I< LINE SPECIFIC FaES Page 1 PR- Overpressure Protection: MAINLINE ( & O M Sec ) A. Mainline Relief Valves - Testing and Inspection: 1. Does the inspection frequency meet the required 15 month but at least once each calendar year criteria? 2. Is there sufficient information to identifj make, type, size, and location of relief valve? Are the found and left set pressures indicated and within the MAOP? Is there any indication that the valve isnat in good mechanical condition? 5. Is there any indication that the valve is not protected h m conditions (dirt, liquids, etc.) that might prevent proper operation? A) Missingraincap B) Plugged drainhole? C) Leaking or corroded control lines, etc.? B. Mainline Regulators - (Presswe Limiting Valves) 1. The inspection fkquency does not exceed 15 months and is within the calendar Year? 2. Is there sufficient information to identify make, type, size and location of regulator and controller? 3. ' Pressures settings are recorded and are within the respective MAOP's? 4. The capacity is calculated, and the volume is sufficient to protect the MAOP? Tab 2-B -Line Specific Files Revised: 2/4/99
9 .- 3 t LINE SPECIFIC FnES Page 2 5. The regulator and controller are checked for leakage or other conditions which may impair their operation? C. Ifthere are no overpressure protection devices on the pipeline, 1. Is protection provided by plants or stations? 2. How is the pipeline MAOP protected? VALVES: Valves, Valve Operators and Blowoffs ( O&M Sa ) A. Valve Identification 1. Are all mainline valves and valve operators, if equipped, identified? 2. Is there sufficient information to identify make, type, size, pressure rating and location (or service) of each valve? 3. Is the pressure rating of the valves commensurate with the pipeline MAOP? B. Valve Inspection 1. Are all valves and operators inspected at intervals not exceeding 15 months but at least once each calendar year? 2. Are all valves inspected for leakage? 3. Are all valves and operators inspected for potentially detrimental conditions, such as: A) Rust or corrosion? B) Stability and support of valve? C) Flange bolts tight? D) Valve box and/or valve is readily accessible? E) Protection against tampering (locked, etc.) if near a public area or public road? C. Valve Operation & Lubrication 1. Are valves and operators at least partially operated at intervals not exceeding 15 months but at least once each calendar year? Tab 2-B - Line Specific Files Revised: 2/4/99
10 -i LliW SPECIFIC FILES Page 3 2. As needed, are valves and operators lubricated to assure ease in operation and to prevent or stop leaking? D. RemarksSection 1. Is there space on the maintenance and inspection form for remarks as to any detrimental conditions? 2. If so, are any conditions noted? 3. If conditions are noted, are remedialor corrective actions indicated? 4. Is it apparent that the Complex Manager is aware of the condition by A) Initialdsignature? B) Documented follow-up agti~n~ taken? Patrolling: (Also visual leakage survey) ( O&M Sec ,202.4,505,506 and 507) A. What are the class locations on the pipeline, and are patrols in 1. Class 1 & 2, at intervals not exceeding 7 1/2 months but at least twice each calendar year at Highway and Railroad Crossings, and 15 months but at least once each calendar year along the rest of the line? 2. Class 3, 4 1/2 months but at least four times a calendar year at Highway and Railroad crossings and 7 1/2 months but a least twice a year at all other places? 3. Class 4,4 1/2 months but at least four times a calendar year at all locations? B. Does the report indicate the observation of Right-of-way conditions, such as 1. Leaks or possible leaks? A) Dead or dying vegetation? B) Change in soil color, etc.? 2. Encroachments or potential encroachmenb? 3. Construction activity in the areas? 4. Water flow and drainage diversions needed or in need of repair? Tab 2-B - Line Specific Files Revised: U4B9
11 * - 2- LINE SPECIFIC FILES Page 4 5. Exposed pipe? 6. Anyother? C. Isthereport 1. Signed by the observer? 2. Initialed by the Complex Manager or Lead? D. Do conditions, such as those in B above, have responses to indicate 1. Further investigation has been made? 2. Corrective action or remedial measures have been taken? 3. Comtive action or remedial measures have been scheduled within a practical time Erame3 Leaks, Damage and Failures: ( ,713, 717, 719,241,475 - O&M Sec201.2,201.3,504, and 607) A. Are leak, damage and failure reports prepared? B. Are notifications made in accordance with Sec. 504 of the O&M Manual? C. Was the repair temporary or permanent? D. If tempomy repair, 1. What was the method of repair? 2. And if a boltsn leak clamp was used, was E. Ifpermanent repair, A) The leak due to a uumshpt '? B) The location marked and recorded to assist in rechecking or when making apemanat repair? 1. And a welded patch was used, was the leak a corrosion pit and on pipe of not more than 40,000 SMYS? Tab 28 - Line Specific Files Revised: 2/4/99
12 H. P LIhE SPECIFIC FEES Page 5 2. And the pipe was replaced, A) Was the pipe of adequate design and hydrostatically tested? B) Were the welds x-rayed? or, C) Were the welds visually inspected by welding inspector on 1) Pipe less than 6" in diameter? or, 2) Pipeline operates at less than 40% of SMYS? and, 3) The welds are so limited that testing is impractical? F. Ifthe pipeline was not repaired, and the line was shut-in or the line pressure lowered, 1. Was the condition not reportable as an incident ( OM Sec. 504)? and, 2. Was the condition safety related? and, 3. Did the condition meet the reporting criteria of a "Safety Related Condition" (O&M, Sec. 400)? G. When the pipe was uncovered, 1. Was an inspection of the pipe and coating made by a technician verified to that bellhole level? and, 2. Wasit recorded on a pipe inspection or bell-hole report? H. Ifthe pipe was replaced, was the intemal surface inspected for corrosion? and, 1. If no corrosion found, was that noted on the pipe inspection fom? 2. If corrosion was found, were the following steps taken? A) B) C) Was adjacent pipe checked for internal corrosion? Did the replacement include the adjacent pipe, if necessary? Were steps taken to minimize the intd corrosion? if so, what steps? Measurement: Relief Valves and Regulators (192739,745 - O&M Sec ) A. Do inspections and tests meet the 15-monWcalendar year fkquency requirement? Tab 2-B - Line Specific Files Revised: 2/4/99
13 .- t- LLNE specific FILES Page 6 B. Have all meter stations on the pipeline been identified? C. Is a form filled out and signed for each station? D. Are capacity calculations entered on the form? E. Are station valves inspected, greased and? F. Are rain caps checked? G. Are R V. drainholes checked? H. Are any repairs, adjustments, etc. indicated in the remarks section? I. Are any problems detrimental to the station operation recorded? If so, are corrective actions "mended or taken? C Q " 2 I I - See Survey Codes and Limits Sheets ( through O&M Sec and 201.3) A. Annualsurvey 1. Are surveys conducted within &month intervals but at least once each calendar year? 2. Are items which would require investigation or remedial action identified on the survey, such as A) Missing test point readings? B) P/S reading below 850 mv? C) Interference suspected? D) E) F) A short detected in road casing? Atmospheric coating/corrosion (3.3 or less)? P/S reading above 2500 mv? G) Etc.? 3. For items requiring remedial measures or indicating trends in that direction, A) Are remedial action foms initiated? Tab Line Specific Files Revised: 2/4/99
14 r LINE SPECZFIC FZLES Page 7 B. Bell-Hole Inspections B) Is the documentation brought to the attention of responsible supervision? C) Wil the items be corrected within a prompt but reasonable time fi-ame? 1. Pipe Inspection Data (Form 7-242) was filled out and signed by employee verified to that bellhole level? Were all pertinent items addressed? Ifwarranted, was a Remedial Action form initiated? C. Shorted Casings 1. Were steps taken to clear the short? or, 2. Was the casinglpipe annulus filled to inhibit corrosion? or, 3. Is the casing being monitored with leak detecting equipment every six months in Class 1 and 2; and, every three months in Class 3 or 4? Tab 2-B - Line Specific Files Revised: 2I4M
... Williams Gas Pipeline
... Williams Gas Pipeline Website: www.williams.com COMMITMENT Williams Gas Pipeline is committed to the protection of the public and the environment through the safe operation and maintenance of its pipeline
More informationSTANDARD INSPECTION REPORT OF AN LNG FACILITY
A completed Standard Inspection Report is to be submitted to the Director within 60 days from completion of the inspection. A Post Inspection Memorandum (PIM) is to be completed and submitted to the Director
More informationCanadian Fire Alarm Association. Fire Alarm System Activation. Fire Alarm with malfunction history
Canadian Fire Alarm Association Discussion topics False alarms Shut off notices Owner s responsibilities Documents required by AHJ Fire Alarm System Activation Fire detection (early warning at insipient
More informationChapter 4: Fire Protection Systems
Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system
More informationSmall LP Gas Jurisdictional Systems. Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West
Small LP Gas Jurisdictional Systems Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West NFPA 58, the Liquefied Petroleum Gas Code standard has been the guidance in the LP Gas/Propane
More informationThe Gas Company Public Awareness Information Pipeline Installation & Maintenance-Southern California Gas Company (SoCalGas)
The Gas Company Public Awareness Information 2010 Pipeline Installation & Maintenance-Southern California Gas Company (SoCalGas) SoCalGas is the nation s largest natural gas distribution company. SoCalGas
More informationUNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY
Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during
More informationInspection and Testing of Water-Based Systems
Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level II Content Outline The candidate for NICET certification at Level II in the Inspection and Testing of Water- Based
More informationMAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS
MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and
More informationGRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS
GRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS Part 212 212.231 Highway-rail grade crossing inspector State inspectors would be authorized to enforce grade crossing system safety regulations. 212.233
More informationa) Establishment of emergency procedures to be followed at the time of an emergency;
5.10 Fire Safety 5.10.1 Introduction The Corporation is responsible for carrying out the provisions of the Ontario Fire Code. This section outlines our responsibilities as well as inspections and testing
More informationTruro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:
Truro Police Department Fire Emergencies Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE: Accreditation Standards: Mass. Gen. Law: Chap. 89 sec 7A, 268 sec 32A Other: Policy: It is the policy
More informationAPPENDIX 4J SECURITY AND SURVEILLANCE SERVICES
TABLE OF CONTENTS APPENDIX 4J SECURITY AND SURVEILLANCE SERVICES 1. INTERPRETATION... 2 2. SECURITY SERVICES... 2 2.1 Security and Surveillance Services Plan... 2 2.2 General Requirements... 2 2.3 Periodic
More informationGAS PIPELINE OPERATIONS
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org GAS PIPELINE OPERATIONS Competencies / Objectives Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE INDUSTRY
More informationHAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus
HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus Issued By: Office of Finance and Administration Name: Chief Financial Officer Effective Date: November
More informationTom Miesner Principal Pipeline Knowledge & Development
Introduction to Control Room Management What it Means and Requires May 20, 2011 By Tom Miesner Pipeline Knowledge and Development Tom Miesner Principal Pipeline Knowledge & Development Pipeline Education
More informationHAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus
HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus Purpose: This document outlines the University of Southern Maine s (USM) contingency plan for emergency
More informationAustralian/New Zealand Standard
AS/NZS 4645.2:2008 AS/NZS 4645.2:2008 Australian/New Zealand Standard Gas distribution networks Part 2: Steel pipe systems AS/NZS 4645.2:2008 This Joint Australian/New Zealand Standard was prepared by
More informationGUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS
GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS [Second Revised Edition] April, 2003 Issued by: Mechanical and Engineering Branch Room 500, Norquay Building
More informationPresented at 6 th Pipeline Technology Conference Hannover, Germany April 4-5, 2011
Presented at 6 th Pipeline Technology Conference 2011 Hannover, Germany April 4-5, 2011 Introduction Recent Pipeline Leak Detection History in the US Inspection Finding and Enforcement Actions Overview
More informationUniversity of Maryland FIRE EVACUATION PLAN
University of Maryland FIRE EVACUATION PLAN PLAZA PARKING GARAGE POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will immediately
More informationLiquefied Petroleum Gas Facility Written Fire Safety Analysis
Liquefied Petroleum Gas Facility Written Fire Safety Analysis For INDEX Page Introduction 2 Conducting the WFSA 2 WFSA CHECKLIST Section I Facility Information 3 Section II Facility Storage Container Information
More informationREED COLLEGE DEPARTMENT OF COMMUNITY SAFETY DEPARTMENTAL DIRECTIVE CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES
CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES Source: Departmental Directive issued by the CS Director. Original publication: January 27, 2011 Latest review & revision: August 2018 Departmental Policy
More informationSafe Operating Procedure
Safe Operating Procedure (Revised 10/17) HOT WORK PERMIT OPERATIONS Authority In recognition of the inherent hazards posed by certain hot work processes, the National Fire Protection Agency adopted Standard
More informationSuburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping
October 20, 2014 Suburban Propane Notice of Public Awareness Additional Information for Customer s Buried Piping In accordance with Federal Safety Standards, you are being notified of the following: The
More informationLiquefied Petroleum Gas Facility Written Fire Safety Analysis
Liquefied Petroleum Gas Facility Written Fire Safety Analysis For Completed by Facility manager Received by Fire Department/Emergency Response representative Date Date INDEX Page Introduction 2 Conducting
More informationFire System Impairment Policy
Fire System Impairment Policy Purpose: To establish procedures to be followed, when a fire protection or suppression system is taken out of service, due to construction, alteration, power outage, repair,
More informationALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ALARM SYSTEMS AND EVACUATION PLANS Guidelines: This checklist covers regulations issued
More informationStatutory Compliance Checklist
Date of Issue: April 2017 Statutory Compliance Checklist This document is for clergy and churchwardens to help them in the maintenance of their Churches. Refer to supplementary notes for further guidance.
More informationHealth and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014
Fire Safety Policy Originator name: Section / Dept: Implementation date: Clive Parkinson Health & Safety March 2014 Date of next review: March 2017 Related policies: Health and Safety Policy Policy history:
More informationFIRE SAFETY AND PREVENTION POLICY
Effective Date: July 26, 2011 Supersedes /Amends: VRS-49/April 2006 Originating Office: Office of the Vice-President, Services Policy Number: VPS-49 PREAMBLE Concordia University (the University ) has
More informationSavard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14
Fire Prevention Program Purpose The Company Fire Safety Plan has been developed to work in conjunction with company emergency plans and other safety programs. This includes reviewing all new building construction
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationDutchess Community College. Emergency Action Plan. Conklin Hall College Residence
Dutchess Community College Emergency Action Plan Conklin Hall College Residence June 2014 1 TABLE OF CONTENTS Purpose Page 3 Introduction Page 3 Evacuation Page 4 Fire Emergencies Page 5 Evacuating Individuals
More informationCity of Duluth Festival Center 04/25
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationDepartment of School Safety and Security MONTGOMERY COUNTY PUBLIC SCHOOLS Rockville, Maryland
Department of School Safety and Security MONTGOMERY COUNTY PUBLIC SCHOOLS Rockville, Maryland Shelter-In-Place Guidelines for a Chemical, Biological, or Radiological Incident and Exposure to Hazardous
More informationRevised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*
1.0 Description of Services Required: Revised March 2015 Fire Alarm Systems Verification Schedule I(A) Services *Manditory Site visit required* Perform the annual fire alarm system and sprinkler system
More informationThe Village of Franklin Gas Safety Pamphlet
The Village of Franklin Gas Safety Pamphlet Emergency Phone Numbers 217-371-4873 or 217-473-5192 Natural Gas Safety and You Your safety is important to us and this pamphlet is designed to provide you and
More informationICC CODE CORNER 2015 International Fire Code
PART II GENERAL SAFETY PROVISIONS CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS SECTION 401 GENERAL 401.1 Scope. Reporting of emergencies, coordination with emergency response forces, emergency plans and
More informationTEN STEP PROCESS PREPARING FIRE SAFETY PLANS
TEN STEP PROCESS PREPARING FIRE SAFETY PLANS STEP 1 CONDUCT FIRE SAFETY AUDIT IDENTIFY BUILDING FEATURES AND HUMAN RESOURCES. STEP 2 APPOINTMENT OF SUPERVISORY STAFF IDENTIFY TRAINED SUPERVISORY STAFF
More informationDate Issued: December 14, 2017 Revision: 2.1
2.1 1. Introduction A is implemented to ensure the fire safety of building occupants or a building area when the Fire Alarm System or a Fire Protection System has been temporarily disabled due to malfunction,
More informationUniversity of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,
University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will immediately
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE
Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping
More informationQUALITY ASSURANCE SURVEILLANCE PLAN (QASP) INTRODUCTION
EXHIBIT 1 PLAN (QASP) CONTRACT No. G S - 01 P - 16 - BW - D - 7004 INTRODUCTION This Quality Assurance Surveillance Plan (QASP) is designed to provide the General Services Administration (GSA) with an
More informationSECTION (16460) - LOW-VOLTAGE TRANSFORMERS
PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution
More informationFIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY
University of Maryland FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your
More information2010 FIRE CODE OF NEW YORK STATE
2010 FIRE CODE OF NEW YORK STATE CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION SECTION 1401 GENERAL 1401.1 Scope. This chapter shall apply to structures in the course of construction, alteration,
More informationICC CODE CORNER 2012 IFC Code & Commentary
907.7 Acceptance tests and completion. Upon completion of the installation, the fire alarm system and all fire alarm components shall be tested in accordance with NFPA 72. A complete performance test of
More information5.07 Air Replenishment Systems
5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is
More informationDiocese of Cleveland Facilities Services Corporation
Diocese of Cleveland Facilities Services Corporation BOILER MAINTENANCE and SERVICING SEASONAL MAINTENANCE - to be performed by trained boiler technician or boiler contractor only: 1. Disassemble the low
More informationMethods, approaches, and procedures to minimize active agricultural land impacts during pipeline construction, surface restoration, and pipeline
Agricultural Impact Minimization Plan Methods, approaches, and procedures to minimize active agricultural land impacts during pipeline construction, surface restoration, and pipeline operation. PennEast
More informationARTICLE VI: SITE PLAN REVIEW
Section 6.01 - Site Plan Review (All Districts) ARTICLE VI: SITE PLAN REVIEW Site plans give the Planning commission an opportunity to review development proposals in a concise and consistent manner. The
More informationUniversity of Maryland Baltimore. Radiation Safety Procedure
University of Maryland Baltimore Radiation Safety Procedure Procedure Number: 5.1 Title: Radiation Safety Involving Irradiators Revision Number: 0 Technical Review and Approval: Radiation Safety Officer
More information2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7
WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves
More informationWELDING, CUTTING, AND BRAZING SAFETY PROGRAM
WELDING, CUTTING, AND BRAZING SAFETY PROGRAM HOT WORK TABLE OF CONTENTS 1.0 Introduction 1.1 Purpose 1.2 Scope 2.0 Responsibilities 2.1 Building Office 2.2 Building Personnel 2.3 Individuals Performing
More informationImpairments to Fire Protection Equipment
Impairments to Fire Protection Equipment INTRODUCTION Buildings and equipment are provided with fire protection and/or detection systems to reduce property damage and interruption to business in the event
More informationChapter 12 HOT WORK OPERATIONS. Purpose:
Chapter 12 Hot Work Operations Chapter 12 HOT WORK OPERATIONS Purpose: To provide written procedures to prevent the outbreak of fire, fire alarm activations, and smoke and odor migration in buildings resulting
More informationSECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 15990 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the Specifier in correctly specifying Mechanical System Testing Adjusting
More informationFunctional Performance Test
Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control
More informationMethods, approaches, and procedures to minimize active agricultural land impacts during pipeline construction, surface restoration, and pipeline
Agricultural Impact Minimization Plan Methods, approaches, and procedures to minimize active agricultural land impacts during pipeline construction, surface restoration, and pipeline operation. PennEast
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ALARM SYSTEMS AND EVACUATION PLANS Guidelines: This checklist covers regulations issued
More informationEMERGENCY PREPAREDNESS: EVACUATIONS
GUIDELINE I. EMERGENCY PREPAREDNESS: EVACUATIONS 1.0 PURPOSE 1.1 To provide guidance for the safe and orderly evacuation of faculty, staff, students and visitors to the University of Pennsylvania campus
More informationBMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT
BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT Guidance and Instructions for Ship-owners, Managers, Masters, Bahamas Recognised Organisations and Bahamas Approved Nautical Inspectors Note: This
More informationEVACUATION PLAN FOR THE CLINTON COUNTY OFFICE BUILDING
EVACUATION PLAN FOR THE CLINTON COUNTY OFFICE BUILDING James R. Langley, Jr. Chairman, Clinton County Legislature 2002 Table of Contents Section I: General Considerations and Planning Guidelines Introduction
More informationREQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES
ISPM 10 INTERNATIONAL STANDARDS FOR PHYTOSANITARY MEASURES ISPM 10 REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES (1999) Produced by the Secretariat
More informationFire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability
Fire Alarm Inspection, Testing, Maintenance Assuring the System s Operational Reliability What does AFAA-NE do? Education We supply the tools our members require to perform within the guidelines of our
More informationCity of Vista Fire Department
City of Vista Fire Department Development Services Section 600 Eucalyptus Avenue, Vista CA 92084 Guideline: Underground Piping for Private Fire Hydrants & Fire Sprinkler Supply. Updated: January, 2008
More informationENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered
More informationTECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE
Page 1 of 12 1. DESCRIPTION (Refer to Figures 1-6.) Viking Electric/Pneu-Lectric Double Interlocked Preaction Systems utilize a Viking deluge valve, pneumatic supervision of the automatic sprinkler system,
More informationWHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly
TOPIC : FIRE DISASTER MANAGEMENT PRESENTED BY :- AMALENDU BANERJEE, DIVISIONAL OFFICER, WBFES WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation
More informationFIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)
FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: AN INTRODUCTION TO YOUR LOG BOOK. This Fire Safety Log book has been prepared to assist the responsible person in coordinating
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationMulch fires, trash can fires, or other fire outside a building should be reported by the following methods:
University of Maryland FIRE EVACUATION PLAN HEALTH SCIENCE FACILITY I (HSF I) POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will
More informationEmergency Action Plan. Revised: 1/22/2018
Emergency Action Plan Revised: 1/22/2018 I. PURPOSE This plan is for the protection and safety of all members of the Branch College community, including students, faculty, staff, and campus visitors. During
More informationFire Prevention Plan. California State University, Chico
California State University, Chico Department of Environmental Health and Safety May 2016 TABLE OF CONTENTS Section Page 1.0 Purpose... 1-1 2.0 Introduction... 2-1 3.0 Responsibilities... 3-1 4.0 Fire
More informationAPPENDIX H (DESIGN SUBMISSION CRITERIA)
APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation
More informationPackaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit
Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing
More informationEMERGENCY ACTION PLAN GOLDEN CITY CASINO HIGHWAY 162 OROVILLE, CALIFORNIA
EMERGENCY ACTION PLAN GOLDEN CITY CASINO HIGHWAY 162 OROVILLE, CALIFORNIA ESHI Tribe TABLE OF CONTENTS TAB A B C D E F G H I TITLE Purpose and Scope Emergency Services Notification of Emergency Services
More informationBuilding, plumbing, and fire safety requirements.
ACTION: Final DATE: 03/09/2007 8:18 AM 3701-17-63 Building, plumbing, and fire safety requirements. (A) The building or buildings in which a residential care facility is located shall be approved by and
More informationFIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION
CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition
More informationDocument No
CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1
More informationJEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM
1 JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM PURPOSE: To minimize potential structural damages and to protect the life safety of all building occupants during periods when the automatic fire alarm
More informationON THE BUTTON A reference guide to environmental ratings used for push button enclosures
ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION...............................
More informationFIRE PROTECTION PROGRAM
Fire Protection Program Page 1 of 13 FIRE PROTECTION PROGRAM 1.0 Objective The objective of this performance assessment is to evaluate the effectiveness of the laboratory's fire protection program as implemented
More informationPANCRETE PAN IN A CAN
PANCRETE PAN IN A CAN Lakeshore Environmental Contractors, LLC 5513 Eastcliff Industrial Loop Birmingham, AL 35210-5418 Office 205-943-5711 Fax 205-943-8317 Web www.lecbiz.com STANDING WATER After a few
More informationSusquehanna University Annual Fire Safety Report 2015
Susquehanna University Annual Fire Safety Report 2015 On August 14, 2008, the Higher Education Opportunity Act was signed into law. In order to comply with this Act, Susquehanna University has prepared
More informationHOT WORK SAFETY PROGRAM:
HOT WORK SAFETY PROGRAM: 1.0 Purpose. To establish safe procedure for open flame or hot work process at Oklahoma City Community College (OCCC) to avoid loss of property and injury to personnel. 2.0 Scope.
More informationFIRE SAFETY MANAGEMENT PLAN
FIRE SAFETY MANAGEMENT PLAN February 2014 2 Document Control Revision: 1 Date: 4 February 2014 Status: Document change control: Approved by EPC Revision # Change Description Date Author 1 Initial document
More informationREQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY
REQUIREMENTS For FIRE DEPARTMENTS State of West Virginia Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY Joe Martin Secretary West Virginia State Fire Commission 1207 Quarrier St.,
More informationS a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e
5.07 Air Replenishment Systems (2016) Reference: SFFC, Section 511.2. Purpose: The purpose of this bulletin is to describe the requirements for air replenishment systems intended to be used to fill firefighters'
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.
More informationPASS Security Plan Checklist
[School District Name] PASS Security Plan Checklist SCHOOL DISTRICT INFORMATION Address: Telephone Number: Fax Number: Number of Employees: Number of Students: School Resource Officer: TIER CONTINUUM:
More informationH&S Forum. Fire Safety Policy Glascote Academy
Fierte Multi Academy Trust Health and Safety Policy Handbook Reference Number HR 103 Issue 6 Approved By H&S Forum Date September 2016 To be reviewed September2017 Policy Title Fire Safety Policy Glascote
More informationDesign & Construction Standards, Revised January
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe
More informationFire Prevention and Emergency Preparedness Plan for Black Oak Wind Farm
Fire Prevention and Emergency Preparedness Plan for Black Oak Wind Farm 1.0 Project Description The Black Oak Wind Farm Project is a commercial scale wind farm project proposed by Black Oak Wind Farm,
More informationAMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER
AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)
More informationFull Service Central Station Fire Alarm Listing Evaluation
Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm
More informationBOARDWALK. Developer s Handbook BOARDWALK FIELD SERVICES, LLC STORAGE COMPANY, LLC PETROCHEMICAL PIPELINE
BOARDWALK Developer s Handbook STORAGE COMPANY, LLC TM TM PETROCHEMICAL PIPELINE TM BOARDWALK FIELD SERVICES, LLC TM TABLE OF CONTENTS Introduction Page 4 First Things First Safety and Reliability Page
More informationIowa Propane Gas Association 2011 Training Descriptions
Iowa Propane Gas Association 2011 Training Descriptions CETP Classes Basic Principles & Practices - 2 days The Basic Principles and Practices class is an entry level course designed to provide all individuals
More information