1 ECOSENSORS 2015 PRICE LISTr-2 PORTABLE AND FIXED AMBIENT OZONE SENSORS A-21ZX Portable digital ozone sensor ppm $ range. Belt clip nylon carry pouch. Options: Pelican case PN $ A-22 Portable Digital sensor, range 0-20ppm. $ plug-in pre-calibrated sensor modules in your choice of two ranges, SMX-20 PPM (0-20 ppm) sensor included, data maximum, minimum, and average data outputs. Sensor can be changed by user. Options: -Pelican case PN $ DL-3 data logger $ DL-SC-3 data cable bundle and data logging software $ SMX-2PPM High Resolution pre-calibrated 0-2ppm sensor included with A-22 $ C-21 Low Cost VOC sensor with both AC and $ battery modes. Audio alarm, relay contacts, 0-2vDC outputs, Options: DL-3 data logger $ SAT-1 remote strobe and alarm $ C-21 Data Cable 0-2V three wire tabbed $ A-22/C-21 DL-3 cable $ EE-2 enclosure $ C-30ZX Ozone monitor and generator controller $ ppm range, audio alarm, relay contacts, accessory connections, adjustable alarm Options: EE-2 enclosure $ , add $ Installation fee SAT-1 remote strobe and alarm $ RAP-2 remote strobe and alarm $ DL-3 data logger $ Data cable for DL-3 $ EZ-1X Ozone sensor and monitor. AC and battery $ modes ppm range. Options: Pelican case PN $ 65.00

2 DIGITAL CONTROLLERS USING SMX REPLACEABLE PRE-CALIBRATED SENSOR OS-4/SM6/SMX-20 Thermostat to control ozone generators or other $ equipment with advanced monitoring and controls. RS-232 output, relays, analog output, 4/20mA with remote SM-6 module and SMX-20 pre-calibrated field replaceable sensor, 0-20ppm range OS-6/SM6/SMX-20 NEMA 4 case digital controller. Failure alarm $ digital display, precise adjustable max, min, fail points. RS-232 output, relays, analog output, 4/20mA with remote SM-6 module and SMX-20 pre-calibrated field replaceable sensor, 0-20ppm range OS-6/SM7/SM-EC NEMA 4 case digital controller. Failure alarm, digital display, precise adjustable max, min, fail points. RS-232 output, relays, analog output, 4/20mA with remote SM-7 module and NEW SM-EC Electrochemical Sensor, 10% accuracy, eliminates most VOC interference, temperature/humidity compensated, field replaceable pre-calibrated sensor, 0-50ppm range $ Options: DL-SC-3 data cable bundle and data logging software $ SAT-1 remote strobe and alarm $ Factory mounted on OS-6 add $ 45.00

3 RS-232 TRANSMITTING REMOTE MODULES COMPLETE WITH SMX PRE-CALIBRATED, USER REPLACEABLE SENSORS SM-6/SMX-20 Remote sensor module transmitting RS-232 $ complete with SMX-20, pre-calibrated user field replaceable sensor, 0-20ppm range SM-6/SMX-2 NO LONGER IN PRODUCTION SM-7/SM-EC NEW Electrochemical sensor, 0-20ppm range, RS-232 transmitting module, 10% or better accuracy, humidity compensated, eliminates most VOC interferences, pre-calibrated field replaceable sensor, $ DISSOLVED OZONE SENSORS/ANALYZERS DO3 Digital Pocket Series battery operated dissolved $ ozone meter. Range 0-5 ppm, LCD readout, records 10 data measurements, repeatable. Kit includes Pelican case, beakers ATI-Q46H-64 ask for price DOM-100 NEW featuring self-cleaning sensors for measuring ozone, free chlorine, hydrogen peroxide, chlorine dioxide ASK FOR DETAILS

4 UV OZONE ANALYZERS UV-100 UV absorption ozone concentration analyzer, Ask for price Built in data logger, relay digital outputs, 3 ranges UV-106L Low range UV analyzer ppm, resolution 0.1ppb Ask for Price UV-106M Mid-range UV analyzer ppm, resolution 0.01ppm Ask for Price UV-106H High range UV analyzer 0-20% by weight, resolution 0.01 wt Ask for Price Options: High efficiency sample filter system with 10 spare filters $ Pelican case $ Rechargeable battery and charger $

5 ACCESSORIES DL-3 Data logger for C-21, C-30ZX, OS-4, includes $ software and cable Add C-21 Data cable to connect 0-2V output From C-21 $ Add Data Cable to connect DL-3 to A-22 $ DL-SC-3 Ecosensors data logging data cable bundle $ and Ecosensors datalogging software for RS-232 transmitting SMX/SM-EC sensors DL-C3 Data logging cable bundle and 3 rd party software $ for RS-232 transmitting SMX/SM-EC sensors EE-2 Environmental enclosure $ /20mA option $ 41 24VAC/DC option $ 26 Heater option $ 6 Fan $ 29 Install C-30ZX $ Install RAP-2 $ SAT-1 Remote tower strobe and alarm $ Can be factory mounted on OS-6, add $ RAP-2 Remote alarm panel with strobe light and audio $ alarm, 4/20mA input and output signal loop connects Install to EE-2 $ OG-3 Ozone calibration source, 0.1ppm or 1.0ppm $

6 CUV-1-B UV-100 carrying case with adapter/charger and $ battery P-20 AC adaptor. 120V 60Hz to 12VDC $ P-20-Intl AC adaptor, for 50Hz/220VAC, multiple plug $ configurations for NON-USA connections CALIBRATION SERVICES (net prices not including sensor or battery replacement) Calibration services for A-21ZX, C-30ZX, $ EZ-1X, OG-3 (replace UV lamp add $ ) Calibration service for C-30ZX in EE-2 $ Calibration service C-21 $ Calibration service for DO3 $ Calibration of UV-100 only (includes replacement of $ Ozone Scrubber) CAL-DOM Inspection, cleaning, calibration of DOM-1, $ includes sensor Pre/Post Calibration Data EZ-1X, C-30ZX, A-21ZX $ 50.00

7 REPLACEMENT SENSORS/LAMP SE-4 replacement sensor for C-21 $ SE-6A replacement sensor for A-21ZX, C-30ZX, EZ-1X $ Factory calibration required SM-5 replacement sensor for OEM 1&2 available in 0.1,1.0 or 10ppm $ **Set up Fee for calibration on 24ft(8mtr) cable $ 50 for up to 5 sensors, $ 100 6up **Custom calibration of SM-5 between ppm flat fee $ 100/batch. **Custom calibration of SM-5 between ppm Flat fee $ 200/batch Sensor DOM-1 $ Factory calibration required Sensor SMX-20, 0-20ppm, for A-22, OS-4 and OS-6 end user $ reseller $ SM-EC Electrochemical sensor, 0-20ppm for OS-6 end user $ reseller $ OG-3 UV lamp $

8 REPLACEMENT BATTERIES (INSTALLED) C-21 9v Rechargeable PN XB-C $ A-21ZX Rechargeable $ A-22 Rechargeable 3 sets total $ 90.00/set

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Product Catalogue. Air and Gas Sensors. Save Life and Energy en PR-grej Product Catalogue Air and Gas Sensors Save Life and Energy High Quality The Swedish company SenseAir is a centre of excellence with over 20 years of experience of IR gas measurements. We develop

More information

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1 Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

R.I.S. (Remote Intelligent Sensor)

R.I.S. (Remote Intelligent Sensor) Use & Description The R.I.S. (Remote Intelligent Sensor) is housed in an environmentally sealed (NEMA 4), tamperresistant enclosure with an external membrane switch control panel. The unit operates on

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3 Single Gas Detector H 2 S CO O 2 SO 2 NH 3 PH 3 Cl 2 ClO 2 NO NO 2 HCN ETO O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within its wide

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

Honeywell EC-P2 EC-P2. Gas Detector CHARGE BATTERY WHEN NOT IN USE. Instruction Manual

Honeywell EC-P2 EC-P2. Gas Detector CHARGE BATTERY WHEN NOT IN USE. Instruction Manual Honeywell EC-P2 EC-P2 Gas Detector CHARGE BATTERY WHEN NOT IN USE Instruction Manual Copyright 2009 by Honeywell International Inc. Release J July 2008 While this information is presented in good faith

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10 User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10 Last Revised October 24, 2018 Copyright 2018 CO2Meter Inc., all rights reserved. Contents INTRODUCTION... 3 FEATURES... 3 MONITOR... 3 LCD DISPLAY...

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR Section 11263 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and installation of chlorine leak detectors as shown on Plans and specified herein. 1.02 MEASUREMENT AND PAYMENT No separate

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

Model D12. Digital Gas Transmitter

Model D12. Digital Gas Transmitter Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours

More information

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec. Indicator for Temperature/Humidity Dec.11 Features - Real time detection of ambient ozone gas level - Full time indicate O3 level - Wall mount with LCD display - Temperature & humidity detection - The

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Leak detector for refrigerant gases R22, R134a, R410A, R407C... PCE-GA3 PCE-LD 1 PCE-GA 70 Pen-sized flammable gas detector Leak detector for refrigerant gases R22, R134a, R410A, R407C... CO2 detector with data logger and software This pen-sized flammable gas detector

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

For the Safety of Your

For the Safety of Your For the Safety of Your Team in Confined Spaces CSM 5000 Portable Multi-Gas Monitor H 2 S OX CO EX Do it Right Do it Safe Power/Select Button Used for turning the CSM 5000 ON and OFF, accessing download

More information

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL S E R I A L N O. M O D E L N O. T e m p. R a n g e 1 - = > 6 0 o F 2 - = 4 0-6 0 o F 3 - = < 4 0 o F - G a s T y p e 1 - R -1 1 2

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

GasAlertMicroClip X3 Specifications

GasAlertMicroClip X3 Specifications GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

Ammonia Leak Detector Manual

Ammonia Leak Detector Manual Ammonia Leak Detector Manual Document No. 70-PHW-1023-R2.5 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park UniSens 2-Wire Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Rd. Delph

More information

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products

More information

esense CO2 Transmitter and Alarm

esense CO2 Transmitter and Alarm esense CO2 Transmitter and Alarm Installation & Manual SE-0010, SE-0012, SE-0013, SE-0014 Rev. 22 November 2015 2015, CO2Meter.com. All Rights Reserved. Table of Contents General... 3 Opening the Housing...

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

WASTEWATER Online UV%Transmission Analyzer

WASTEWATER Online UV%Transmission Analyzer Water Quality Measurement Solutions Online UV%Transmission Analyzer Detailed Specifications Instrument Overview With over 30 years of optical design technology expertise HF scientific has developed it's

More information

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park GasSens Hydrogen Peroxide Monitor Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph

More information

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector. Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version) PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

HIGH CAPACITY PRODUCT LINE

HIGH CAPACITY PRODUCT LINE HIGH CAPACITY PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980

More information

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date: Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories TOCSIN 90 SYSTEM UPGRADE Use existing MK3 Pellistor Flammable Gas Sensors and upgrade to

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

GLD-30 Gas Leak Detector

GLD-30 Gas Leak Detector GLD-30 Gas Leak Detector Installation, Operation & Maintenance General: The Archer Instruments GLD-30 is an ambient air monitor, used to detect the presence of a target gas (or gases) and to alert operators

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.

More information

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C Dataloggers Monolog 2 offers a comprehensive range of portable self-powered datalogging devices for numerous sensor types that utilise the latest electronics and software. A range of common software and

More information

Hygrometer / Air Quality Meter

Hygrometer / Air Quality Meter Hygrometer / Air Quality Meter PCE-313 A Professional Thermohygrometer with SD Card Memory / Data Logger measures temperature and humidity by internal sensor and temperature by K type thermocouple calculates

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight

More information

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone: CM-1 CO ppm MANUFACTURED BY Aerionics, Inc. Sioux Falls, SD Phone: 1-877-367-7891 Email: info@aerionicsinc.com www.macurco.com Detectors for use with Fire and Security Systems The Macurco CM-E1, GD-2B,

More information

3 3SP_O3_5 C Package

3 3SP_O3_5 C Package 15x15 O3 Sensor 5 ppm C Package 110-407 BENEFITS Small Size with Low Profile (20x20x3 mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Low Power Consumption Individually Calibrated (NIST

More information

Section K CHLORINATION EQUIPMENT

Section K CHLORINATION EQUIPMENT Section K CHLORINATION EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnish and install chlorination equipment and appurtenances necessary to complete work shown or specified. The equipment is to

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics 4000TOC Sensor THORNTON Leading Pure Water Analytics 4000TOC Sensor Fast, continuous measurements No reagents or chemicals needed No moving parts Meets USP 643, 645,Ch P, EP 2.2.44, and JP requirements

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATI AND OPERATING INSTRUCTIS PRODUCTS CMD Series CO Detectors FGD Series Refrigerant Detectors AGD Series Toxic Gas Detectors CGD Series Combustible Gas Detectors (All transmitters are factory set

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides

More information

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820? MSA Gas Detection for the Water and Wastewater Industries Does your facility meet NFPA 820? www.msagasdetection.com A Passion for Safety MSA s passion for safety comes from almost a full century of manufacturing

More information

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

SENTRY-MS Mono-static Multi-gas Open Path Analyzer SENTRY-MS Mono-static Multi-gas Open Path Analyzer Air Monitoring Where You Need it... The Cerex Sentry-MS Multi-gas Open Path Analyzer is specifically designed for rapid deployment for a variety of indoor

More information

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection. Intuitive and simple menu Safety by password function Applications Disinfection Cooling water Process Water K 100 W DES Drinking Water / Beverages Description The instruments of the K100 series are high-quality

More information

HIGH CAPACITY PRODUCT LINE

HIGH CAPACITY PRODUCT LINE HIGH CAPACITY PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980

More information

SAFESITE Multi-Threat Detection System

SAFESITE Multi-Threat Detection System SAFESITE Multi-Threat Detection System The SAFESITE Multi-Threat Detection System simultaneously monitors and wirelessly communicates six potential threats: CWAs, VOCs, TICs, gamma radiation, combustible

More information

Hydrazine Analyzer Series 2171 Specifications

Hydrazine Analyzer Series 2171 Specifications Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination

More information

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1) ST-IAM Sensor Transmitter Integrated Area Monitor Check / Calibration Procedure* Content Page 1-Introduction 2 2-Bump Test 2 3-Calibration 3 a. Exchanging sensor board 3 b. Gas Calibration 3 4-Additional

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 ALL-WEATHER REFRIGERATED SAMPLERS AS950 ALL-WEATHER REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 All-Weather Refrigerated

More information

Using the MiniRAE 2000 & ppbrae PID

Using the MiniRAE 2000 & ppbrae PID MiniRAE 2000 Using the MiniRAE 2000 & ppbrae PID Firmware v. 1.20 (rev C) The Hazardous Environment Detection Company Training Agenda: MiniRAE 2000 & ppbrae features Turning on the MiniRAE 2000 & ppbrae

More information

OCCUPATIONAL HEALTH, SAFETY & INDUSTRIAL PRODUCTS

OCCUPATIONAL HEALTH, SAFETY & INDUSTRIAL PRODUCTS OCCUPATIONAL HEALTH, SAFETY & INDUSTRIAL PRODUCTS Safety Equipment & Supplies Pages 405-1000 Toll Free: 1.800.461.1713 E-mail: sales@northernsafety.ca SAFETY EQUIPMENT & Safety Cans & Containers...............................

More information

3SP_H2S_50 Package

3SP_H2S_50 Package 15x15 H2S Sensor 50 ppm Package 110-304 BENEFITS Small Size with Low Profile (20x20 x3.0mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Low Power Consumption Individually Calibrated

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

UniSens 2-Wire Gas Transmitter

UniSens 2-Wire Gas Transmitter O & M Manual UniSens 2-Wire Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New

More information

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH Data sheet Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH Danfoss gas detecting sensor program, type GD is a range of products designed to meet all industrial refrigeration and air conditioning applications.

More information

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm Oxygen Deficiency Monitor and Oxygen Analyzers Oxygen Sensors for 0-25% and 0-1000ppm ABOUT PUREAIRE MONITORING SYSTEMS PureAire is an experienced safety gas detection manufacturer providing long lasting

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information