1 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to the Canadian fire protection industry for over 40 years. LYNCAR provides fire protection wholesalers with thousands of products including: Escutcheons and wallplates A full line of GLOBE sprinkler heads Sprinkler gauges Signage and labels for fire protection systems Beam clamps, ring hangers and other pipe-hanging accessories for sprinkler systems Electrical items such as Potter switches Fire-rated specialty chemicals such as pipe sealants and premixed anti-freeze Specialty valves Head guards Many other fire sprinkler specialties Please contact our order desk or check our website for more information on how we may serve your customers fire protection needs, or to get our fire protection wholesale catalogue.
2 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page -37 The BEST Plumbing Specialties. One Source. 37 SPrInKLEr heads SPrInKLEr heads STAnDArD response 1/2 IPS G G Temperature rating 155º - 5mm glass bulb sprinklers 1/2 orifice x 1/2 NPT - K FACTOR culus & FM approved G G G G SPrInKLEr heads QUICK response 1/2 IPS Upright - 1/2 IPS brass Horizontal sidewall - 1/2 IPS chrome Pendent - 1/2 IPS chrome G G Temperature rating 155º - 3mm glass bulb sprinklers 1/2 orifice x 1/2 NPT - K FACTOR culus & FM approved G G G G Upright - 1/2 IPS brass Horizontal sidewall - 1/2 IPS chrome Pendent - 1/2 IPS chrome
3 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page SECTIon head ConCEALED, S.r. & Q.r. ThE InCh Specialties Quality, Durability, Reliability SPrInKLEr heads - Water working pressure rating 175 PSI - Factory tested hydrostatically to 500 PSI - Maximum low temperature glass bulb rating is -67ºF (-55ºC) - Strong wrap around pin, drop in design - Available in 155º - White plate 2-3/4 diameter - culus and FM approved G W G W Quick Response Standard Response residential ThE InCh - Water working pressure rating 175 PSI - Factory tested hydrostatically to 500 PSI - Maximum low temperature glass bulb rating is -67ºF (-55ºC) - Strong wrap around pin, drop in design - Available in 155º - White plate 2-3/4 diameter - culus and FM approved G W Residential residential SPrInKLEr head 1/2 IPS - 3mm frangible glass bulb - Residential sprinklers are the ultimate in life safety and fire control - Install in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. - Temperature rating 0 155º F (68º C) - Water working pressure rating 175 PSI - Chrome pendent 155º - culus approved G Pendent, K FACTOR 5.6
4 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page -39 The BEST Plumbing Specialties. One Source. 39 recessed ESCUTChEon SPrInKLEr - Recessed escutcheon for pendent sprinkler head - Chrome or white standard - Also available in black & brass - Sprinkler head sold separately FInISh IPS Chrome 1/ Chrome 3/ White 1/ White 3/4 ESCUTChEon recessed ThrEADED 2 PC PLATE - Made to allow for minor adjustments to pipe or ceiling pitch - Can be removed or reinstalled, allowing access above removable ceiling panels without shutting down the sprinkler system - Threaded skirt & cup for 1/2 adjustment Chrome White ESCUTChEon recessed retrofit - 3 piece recessed escutcheon - Centre section splits into 2 pieces and snap together - Chrome plated escutcheon without shutting down the system r Chrome, 1/2 IPS STAnDArD ESCUTChEon 1 PC - Standard Escutcheon for pendent sprinkler head. - Chrome or White standard. FInISh IPS Chrome 1/ Chrome 3/ White 1/ W White 3/4 oversized repair PLATE - Increase the coverage area when using 2 pc recessed plates or 1 pc plates - Used in repair when hole is oversized from previous sprinkler - Also suitable for earthquake zone areas where 1 is required for the flange - Total coverage is 5 - Sprinkler head sold separately Chrome White
5 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page SECTIon Specialties Quality, Durability, Reliability SPrInKLEr head CABInETS - LYNCAR stocks spare head cabinet for 6 or 12 heads - Sprinkler head sold separately head box head box head GUArDS ESCUTChEon retrofit nipples ChEATEr BrASS hex - LYNCAR stocks many different head guards for fire sprinkler applications STYLE Red 1 pc 2 hook 1/2 or 3/4 IPS Red 2 pc heavy duty 1/2 IPS Red 1 pc 2 hook with shield Mini guard chrome for 1/2 or 3/4 IPS Head guard for recessed plate - These rings are used to conceal oversized holes and cutting errors in ceiling tiles, drywall or other ceiling materials - These products split so the system does not have to be shut down or the sprinkler head removed. The 1-1/2" ID is standard and the 2-1/2" ID is for semi recessed escutcheons - 4" coverage FInISh ID od White - Kydex 1-1/ White - Kydex 2-1/2 4-1/2 IPS brass cheater nipples, used when the sprinkler head requires adjustment down from the existing position ADUSTMEnT / / / order Desk: (800) lyncar.com 24 hr. order Fax: (800)
6 _specialties:pcsectiond_new 2/6/2012 4:46 PM Page -41 The BEST Plumbing Specialties. One Source. 41 PoTTEr FLoW & PrESSUrE SWITChES SWITCh PoTTEr FLoW - Potter flow switch - Paddle type flow switch - Available from 1 to 10 pipe sizes - Service pressure to 450 PSI, - ULC and FM approved SIZE / SWITCh PoTTEr PrESSUrE ** Also available as double contact models SWITCh PoTTEr osy & PCvS - Potter pressure switches - Single & double contacts - ULC and FM approved A Low pressure double contact (PS10-2A) Low pressure single contact (PS10) Air pressure single contact (PS40) ** Pressure supervision switch (PS120) ** - Potter OSY & PCVS supervisory switches are double contact switches, for OSY valves or for PIB valves - FM approved part# OSY part# PCVS OSY PCVS order Desk: (800) lyncar.com 24 hr. order Fax: (800)
E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing
Extended Coverage Sprinklers Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra
More informationAdditional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140
Bulletin 033 Rev. A Model F1 RES LL Residential s for Design Density of.05 gpm/ft 2 Bulletin 033 Rev. A Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection.
More informationModel F3 Dry Sprinklers
Features 1. The Model F3 utilizes Belleville Spring Closure Technology 2. Styles available for Model F3 Dry s: Pendent Recessed Pendent Concealed Horizontal Sidewall Recessed Horizontal Sidewall 3. 1½"
More informationModel G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5
Bulletin 034 Rev. F Model G5 Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Product Features Model G5
More informationModel F1 Residential Sprinklers for Design Density of.10 gpm/ft 2
Model F1 Res s engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationFIRE SUPPRESSION SPRINKLER SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationSECTION SPRINKLER SYSTEMS
SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department
More informationModel F1FR Series Quick Response Standard Spray
Model F1FR 56 Types Standard Upright Standard Pendent Model F1FR 56 Recessed Types Standard Pendent/F1/F2/FP Model F1FR 56 Concealed Types Standard Pendent Listing & Approvals 1. Underwriters Laboratories
More informationModel F1 LO K 8.0 (115 metric) Standard Response Sprinklers
Model F1 LO K 8.0 (115 metric) Standard Response s Bulletin 117 Rev. Z Bulletin 117 Rev. Z Model F1 LO Standard Spray Upright Standard Spray Pendent Extended Coverage Pendent Conventional Model F1 LO Recessed
More information40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS
VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 standard spray sprinklers are designed to produce large discharge capacity in a hemispherical pattern standard in commercial applications.
More informationTHE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION
SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression
More information40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date
VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available
More informationDRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking dry vertical sidewall sprinklers are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems,
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationTECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.
September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction
More informationA. Section includes wet-pipe sprinkler system, system design, installation, and certification.
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes wet-pipe sprinkler system, system design, installation, and certification. 1.2 REFERENCES A. General: Comply
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More informationModel G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler
UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationSECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM
SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationUL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response
SPRINKLER HEADS SMOOTHFLOW AUSTRALIA SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed RESPONSE Quick response Standard response COLOURS Natural brass Chromed Power coated white TEMPERATURE
More informationSECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE
SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationModel vkfd28b braided flexible sprinkler drops (lpcb approved)
Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM
More informationSTANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS
Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent
More information40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS
* * See page 2 for FM Approved product configurations SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 ECLH sprinklers are designed with a K14.0 orifice size to provide added coverage at normal
More informationNorminal Sprinkler Temperature Rating
SPRINKLER HEAD Horizontal Sidewall Sprinkler MODEL: SD1133, SD1121 DESCRIPTION The SD1133, SD1121, ½ orifice, standard horizontal sidewall sprinkler is designed for standard or recessed installation. The
More information40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 5.6 K-Factor will aid in the system
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal
More informationB. Section Identification for Fire Suppression Piping and Equipment.
SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationStandard response. elo sprinklers
Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent
More informationINSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA
Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL
SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSECTION WET FIRE SPRINKLER SYSTEMS
SUNY GENESEO 211310-1 PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in
More informationModel MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)
Model MBEC-14 (SIN R6932) Features 1. Designed to be installed on piping that is supported by the primary structure, not the purlins. 2. Provides Extended Coverage Ordinary & Extra Hazard protection to
More informationstandard response/ quick response extended coverage
1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry
More informationDISCONTINUED PRODUCT
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 residential sprinklers are designed to meet the requirements of NFPA 13, 13D and 13R for residential use in a variety of room sizes, depending
More information40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The V3806 concealed, designer style sprinkler allows up to 1/4"/8 mm adjustment to accommodate concealment needs. The separate two-piece mounting cup/cover plate
More informationA. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.
More informationTECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.
Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to
More informationHORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA
Page of 5. DESCRIPTION Viking Horizon Standard Response Flush Pendent Sprinkler VK400 is a small, flush, solder link and lever spray sprinkler. Designed for use with concealed piping, the unit is mounted
More informationTECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).
Page 1 of 6 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation on concealed
More informationec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)
Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers
More informationHORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA
Sprinkler 53a 1. DESCRIPTION Viking Horizon Quick Response Flush Pendent Sprinklers are small, flush, solder link and lever spray sprinklers. Designed for use with concealed piping, the units are mounted
More informationNon-Storage / Special Protection / Storage Sprinklers
Non-Storage / Special Protection / Storage Sprinklers General Information Automatic sprinkler protection is recommended for industrial and other buildings having combustible construction or combustible
More informationNorminal Sprinkler Temperature Rating
SPRINKLER HEAD Conventional Sprinkler MODEL: SD1025, SD1026 DESCRIPTION The SHIELD Sprinkler, SD1025, SD1026 (Glass Bulb Type) ½ Orifice, Conventional sprinkler is designed for standard or recessed installation.
More informationSPRINKLERS TABLE OF CONTENTS
SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
More informationResidential Sprinkler For Sloped Ceilings
Bulletin 035 Rev. H Residential For Sloped Ceilings Bulletin 035 Rev. H Guidelines for Listed Residential installations below Sloped Ceilings The installation guidelines cover Residential Models: F1 Res
More informationmirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)
January 1, 2011 Sprinkler 92a 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationRefer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.
Page 1 of 5 1. DESCRIPTION A. Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler installation wrench. NFPA 13
More information40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response
This concealed, designer style sprinkler allows up to 1/2"/13 mm adjustment to accommodate concealment needs. The standard design provides a consistent hemispherical spray pattern. The separate two-piece
More informationquick response horizontal sidewall sprinkler vk360 (K8.0)
February 26, 2010 Sprinkler 43o 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature
More informationExaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V3426 residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 6.9 K-Factor will aid
More informationTECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.
May 14, 2010 Sprinkler 131a 1. DESCRIPTION Viking Intermediate Level In-Rack Sprinklers consist of a water shield installed on specifically listed and/or approved frame style standard and quick response
More informationMICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION The Viking Microfast Standard/Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK605 is thermosensitive spray sprinklers available in several different finishes
More informationA. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13.
21 10 00 PART 1 - GENERAL 1.01 SCOPE A. The following standards and procedures apply to the design and installation of all wet pipe and dry pipe sprinkler systems. The design of fire suppression systems
More informationA. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:
SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationSTANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationstandard/quick response extended coverage light and ordinary hazard elo sprinklers
January 27, 2012 Sprinkler 83a 1. DESCRIPTION Viking EC/QREC Light and Ordinary Hazard Extra-Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different
More informationThe Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure
Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.
More informationmirage Quick response concealed pendent sprinkler vk464 (K8.0)
January 1, 2011 Sprinkler 55a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK464 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems
More information40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS
MODELS/S.I.N. V2709 AND V2710 VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27, standard spray horizontal sidewall sprinklers are designed for up to ordinary Hazard per NFPA 13, and can
More informationmirage Quick response concealed pendent sprinkler vk465 (K4.2)
January 1, 2011 Sprinkler 64a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK465 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems
More informationEC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Pendent Sprinkler VK572 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal
More informationquick response Sprinkler 105a October 25, 2010
October 25, 2010 Sprinkler 105a 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed
More informationQUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA
April 2, 2010 Sprinkler 4h 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Fusible Element Horizontal Sidewall Sprinkler VK08 and HP Sprinkler VK20 are small thermosensitive solder link
More informationTABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5
DOC Cremer Heating and Hot Water Plant Project Number: M 1411-04 TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION 21 30 00- WATER BASED FIRE PROTECTION SYSTEMS... 5 SECTION 22 40 00 -PLUMBING
More informationMicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION The Viking Fusible Element Horizontal Sidewall Sprinkler VK613 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings
More informationVK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design
More informationMLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN
DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE
More informationqr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013
March 14, 2013 Sprinkler 42h 1. DESCRIPTION Viking Quick Response Fusible Element Upright and Pendent Sprinklers are small thermosensitive solder link spray sprinklers available with various finishes and
More informationMicrofast quick response Fusible element hsw sprinkler
Page 1 of 7 TECHNICAL DATA 1. DESCRIPTION The Viking Microfast Quick Response Fusible Element Horizontal Sidewall Sprinkler VK307 is a small thermosensitive solder link spray sprinkler available with various
More informationDISCONTINUED PRODUCT. reference publication
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V39 ECLH concealed sprinkler is designed with a K8.0 orifice size to provide added coverage at normal light hazard operating pressures. The design
More informationSprinkler Guards Model C Model D
Bulletin 208 Rev. G Sprinkler Guards Model C Model D Bulletin 208 Rev. G Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are constructed
More informationSPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS
SPRINKLER HEAD Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION The SD2133, SD2121, ½ orifice, standard vertical sidewall sprinkler is designed for standard installation. The design provides
More informationTECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400
Page 1 of 8 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry
More informationTECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600
1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction
More informationSTANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617
May 14, 2010 Sprinkler 85h 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and
More informationS p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions
SPecial Purpose Sprinklers The Tyco ILLUSION 11.2 K-factor sprinkler is designed specifically for Las Vegas' standards. A fast response, extra large orifice concealed pendant sprinkler, the ILLUSION is
More informationB. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.
(816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationstandard response large orifice dry
February 26, 2014 Sprinkler 101o 1. DESCRIPTION Viking Standard Response Large Orifice Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationmicrofast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)
February 13, 2009 Sprinkler 43a 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various
More informationA sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.
Control / Residential / Suppression Mode Sprinklers Automatic sprinkler protection is recommended for industrial and other buildings having combustible construction or combustible occupancies. There are
More informationB. Related Sections: The following Sections contain requirements that relate to this Section.
SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationmirage standard response concealed pendent sprinkler vk492 (K5.6)
Page 1 of 6 1. DESCRIPTION Viking Mirage Standard Response Concealed Pendent Sprinkler VK492 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the
More informationTECHNICAL DATA. Page 1 of 6
Page 1 of 6 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet
More informationSECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section
PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide
More informationModel F1 FR56 Recessed. Quick Response Standard Spray. Bulletin 014 Rev. G OJ
Bulletin 014 Rev. G OJ Model F1 FR56 Series Quick Response Standard Spray Model F1 FR56 Types Standard Upright Standard Pendent Conventional Vertical Sidewall Model F1 FR56 Recessed Standard Pendent/F1/F2/FP
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 21 1314W - AUTOMATIC SPRINKLER SYSTEMS (WET PIPE SYSTEMS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION
SPRINKLER HEAD Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION The SHIELD Sprinklers, SD1010, SD1015, SD1030, SD1032 (Glass Bulb Type), Standard Orifice,
More information1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:
SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.