ZJ-FA10. Advanced Ionizer with Visible Discharge Status. Ionizer (Advanced Fan Type) Features. Sensing Charge and Discharge Status

Size: px
Start display at page:

Download "ZJ-FA10. Advanced Ionizer with Visible Discharge Status. Ionizer (Advanced Fan Type) Features. Sensing Charge and Discharge Status"

Transcription

1 Ionizer (Advanced Fan Type) Advanced Ionizer with Visible Discharge Status charge and discharge status. Efficient ionization with dual-mixing variable DC method. Simple maintenance with completely open construction. Be sure to read Safety Precautions on page Features Charge and Discharge Status workpiece charge and discharge status using the sensor on the face of the. Cleaning Sen- Easy-to-read indicator display on top of the. sing / Positively charged workpiece Ionization Connect an Electrostatic Sensor Head More accurate checking of remote workpiece charge and discharge status is possible by connecting the 100 Electrostatic Sensor Head. Discharge completed Easy-to-read Indicators All indicators are located on top of the for greater visibility. Charge/discharge status, ion balance/cleaning alarms, and other operation status can be checked easily. Alarm signals can also be sent as external outputs. Multi-level indicator Switches between sensing charge and discharge status, ion balance, and fan speed (air volume) Cleaning indicator Two-level warning/ alarm indication Power supply indicator Error alarms Lit when discharge errors occur. Stops discharge at the same time. 1270

2 Efficient Ionization and Slimmer Unit with Dual-mixing Variable-DC Method Thorough mixing and blowing of generated ions by the fan Discharger Fan together with sensing and control of the ion balance. This method enables more sophisticated use of both ionization Ion Balance Sensor speed and ion balance performance. Innovations in the internal structure have made the Sensor dramatically slimmer. Slim Feedback 55mm Wide Range of Installation Options Perfect for Cell Manufacturing Use the ZJ9-FA-BR01 Pipe-mounting Bracket to rotate the Sensor up, down, left, or right after installation by turning a knob. The Sensor can also be mounted to pipes in the cell manufacturing line. Cleaning / Sensor can be adjusted to any direction after installation. Pipe mounting makes the Sensor suitable for a variety of installation environments. Completely Open Construction Means Simple Maintenance The front panel opens up in three stages to a maximum of 180. The discharger, internal parts, and the fan can be simply and effectively cleaned. The ion output status is constantly monitored and a cleaning warning (output) given before the ionization characteristics deteriorate. The facilitates on-site maintenance to maintain optimal ionization performance. Ionization performance Warning before performance deteriorates Alarm when deterioration starts * Earlier models only had the alarm display. 2-level display Operating time 1271

3 Ordering Information Ionizer Model Accessories Type Pipe-mounting Bracket (for 28-dia. pipes) Replacement Filters Replacement Dischargers Model ZJ9-FA-BR01 ZJ9-FL92 (pack of 10) ZJ9-NDT08F (pack of 8) Ratings and Specifications Ionizer Item Model Cleaning / Power supply voltage Current consumption Discharge voltage Discharge method Airflow Discharge time * Ion balance * 24 VDC ±10% ripple (p-p) 10% max. 600 ma max. ±7kV max. Dual-mixing variable-dc method 1.8m 3 /min max. Within 3.0 seconds ±10V max. Amount of generated ozone 0.01 ppm max. (measured at a distance of 10 mm from air outlet) Main functions External outputs External Sensor Fan speed adjustment, manual balance adjustment, charge/discharge status display, cleaning display/output, error display/output, key lock, connection to an external Electrostatic Sensor Warning output/cleaning output: Output from photo-mos relay (300 ma at 30 VDC) 100 Electrostatic Sensor Head Ambient temperature Ambient humidity Weight (packed state) Materials Accessories Operating and storage: 0 to 50 C (with no condensation or icing) Operating and storage: 35% to 65% (with no condensation or icing) Approx. 2.7 kg Unit: ABS, Discharger: Tungsten Instruction sheet, AC Adapter, I/O Cable, English warning labels (3 types) * Measurement location: center of air outlet at a distance of 300 mm Discharge time: From ±1,000 V to ±100 V Ion balance measurement time: 10 seconds Plate monitor: 150 x 150 mm, 20 pf 1272

4 Engineering Data (Typical) Discharge Area vs. Discharge Time Distance direction Ion Balance (Position Fluctuation Characteristics) mm 3s 4s 5s 2s 1s 300mm A B C D E 50mm F G Right to left Ion balance (V) mm Safety Precautions 4 6 A B C D E F G Measurement location [Measurement conditions] Airflow: Maximum Discharge time: From +1,000 V to +100 V Plate monitor: 150 x 150 mm, 20 pf Cleaning / Refer to Warranty and Limitations of Liability on page F-2. WARNING Precautions for Correct Use This product is not design or rated for ensuring Do not use the product in atmospheres or environments that safety of persons. Do not use it for such exceed product ratings. purpose. 1273

5 Dimensions (Unit: mm) Ionizer Cleaning / dia. mounting holes Mounting Hole Dimensions 5-M ±0.1 90±

6 Using ZJ9-FA-BR01 Pipe-mounting Bracket 2-M dia Cleaning / Cat. No. E874-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1275

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization Ionizer Basic Fan Type High-speed, High cost performance Ionization in Fan Ionizers High-speed Ionization A Unique Structure Provides a Uniform Airflow The newly developed airflow control system (AFCS)

More information

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600 Slimmest in the Industry: High-speed Dust Control Unique twin-fan construction. HEPA filter with high filtration. Be sure to read Safety Precautions on page 1250. Features Clean Slimmest in the industry:

More information

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression. 117 Wide-area Ionizer Steady-state DC Method SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.191 No compressed air necessary guide... P.11~ General precautions...

More information

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual Static Eliminators Overhead Ionizing Blower Model IN5130 Instruction Manual 1 Description Contents Model IN5130 1 About Ptec Technology 1 Features 1 Power Requirements 2 2 Operation and Use Environmental

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY S I G N A T U R E S E R I E S WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE.... EST LIFE SAFETY PRODUCTS...... DETECTORS AND MODULES... EDWARDS SYSTEMS TECHNOLOGY TM SIGNATURE SERIES LIFE SAFETY DEVICES.

More information

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

Chargebuster Overhead Ionizer Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6545 Chargebuster Overhead Ionizer Installation, Operation and Maintenance Figure 1. EMIT 50682 Chargebuster Overhead Ionizer Figure 2. EMIT 50681 Chargebuster Overhead Ionizer Made

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Column-shaped Sensor Capable of Sensing Range Setting Ensures the stable detection of a variety of objects regardless of the color, transparency, or material (metallic

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Bench Top Ionizer Installation, Operation and Maintenance

Bench Top Ionizer Installation, Operation and Maintenance TECHNICAL BULLETIN TB-5512 Bench Top Ionizer Installation, Operation and Maintenance Made in America common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and

More information

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division 966A AIR IONIZER Operation Manual Precautions...1 Safety precautions...1 Other precautions...1 Outline...2 Structure and kinds of the ionizer...2 Specifications...2 Characteristic...3 How to Install 966A

More information

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10 Ionizer Nozzle type Series IZN10 Electrode needle contamination detector Outputs maintenance signal when detects stain or wear of an electrode needle always. Detects optimal maintenance time, reduced labor

More information

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10 Ioniser Nozzle type Dust removal and static electricity elimination by air blow Eliminates dust clinging to lamp covers. Spot type static electricity elimination Prevents electrostatic breakdown of electric

More information

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia. Infrared Thermosensor CSM DS_E_3_2 Achieve Low-cost Measurements with an Infrared Thermosensor. The has an electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple

More information

ELIMINOSTAT DC-ESR-CL-S2

ELIMINOSTAT DC-ESR-CL-S2 Static Clean Instruction Manual DC Voltage Application Method Static Eliminators Static Eliminator with Integral Power Supply ELIMINOSTAT DC-ESR-CL-S2 Thank you for purchasing the Static Eliminator ELMINOATAT

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level Sensor EK-L CSM_EK-L_DS_E_4_ Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to 11 mm or 1 to mm Built-in

More information

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable R Label Detection Sensor E3S-CD68/63 Detect Labels Regardless of Label Color or Luster, Bottle Color or Clarity H High-performance circuitry detects wide variety of labels on clear and colored bottles

More information

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

STATIC ELIMINATOR I443A INSTRUCTION MANUAL STATIC ELIMINATOR I443A INSTRUCTION MANUAL Thank you for purchasing a Static Eliminator. It is designed to eliminate the static charge from a charged object. Please read this manual before operating the

More information

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower IONIZING AIR BLOWER MODEL:QUICK442 INSTRUCTIONS Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower The Ionizing AIR BLOWER (OVERHEAD) is a member of the ionizing air blower family. The BLOWER OVERHEAD

More information

OPERATION INSTRUCTION

OPERATION INSTRUCTION IONIZING AIR BLOWER PC OPERATION INSTRUCTION Thank you for purchasing this PC Ionizing Air Blower. It is designed to eliminate the static electricity from a charged object. Please read this manual before

More information

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN 801 Ionizing Blowers Instruction Manual Contents BFN 801 Description

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

MCH Series Drives. HVAC Application Guide. ag-mch-e2

MCH Series Drives. HVAC Application Guide. ag-mch-e2 Drives HVAC Application Guide ag-mch-e2 % Flow, Torque, HP AFFINITY LAWS Most HVAC systems are designed to perform during peak load conditions that rarely occur during the year. Various flow control methods

More information

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B

More information

onlinecomponents.com

onlinecomponents.com Reflective Mapping CSM DS_E_2_1 Ideal for Mapping Liquid Crystal Glass Plates on Cassette Trays Be sure to read Safety Precautions on page 3. Features Detects glass plates without being influenced by the

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS HEATING ONLY: DRUM & TUBE HEAT EXCHANGER 409 STAINLESS STEEL 14 GAUGE HEAT EXCHANGER

More information

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor CSM DS_E_4_ Excellent PET Bottle Detection New detection method that is independent of bottle shape, position, and contents. Automatic

More information

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN Static Eliminators BFN 803 Ionizing Blower TRANSFORMING TECHNOLOGIES,

More information

Remote Storage Safety 3 Alarm Installation Guide

Remote Storage Safety 3 Alarm Installation Guide Product Description Remote Storage Safety 3 Alarm Installation Guide Model: RAD-0102-6 Thank you for selecting the RAD-0102-6 Remote Storage Safety 3 Alarm. This monitor is designed to protect customers

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Cylindrical Ultrasonic Proximity Sensor with Separate Amplifier Unit Stable operation for a variety of objects regardless of color, transparency, or material (metallic

More information

M3050 Detector Operator s Manual

M3050 Detector Operator s Manual FABRICON SYSTEMS ALBERTA 2008 INC. Keeping you in Front M3050 Detector Operator s Manual Telephone: (403)652-2127 Mailing Address: Shipping Address: Fax: (403)652-3027 Box 5996 402 Ellis Crescent S.E Email:

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range LED Optimized Drivers Model: Series Environmental 40W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive Mode: PFC

More information

OG5000 Ozone Generator Model OG5000B-A. User Manual

OG5000 Ozone Generator Model OG5000B-A. User Manual OG5000 Ozone Generator Model OG5000B-A Copyright 2017 610-0082-01H DCN7785 Teledyne API 25 September 2017 Contents CONTENTS... 1 FIGURES... 2 TABLES... 2 1. GENERAL PRECAUTIONS... 3 Safety... 5 Safety

More information

IONIZING AIR BLOWER INSTRUCTION MANUAL

IONIZING AIR BLOWER INSTRUCTION MANUAL IONIZING XC AIR BLOWER INSTRUCTION MANUAL Thank you for purchasing this XC Ionizing Air Blower. It is designed to eliminate the static electricity from a charged object. Please read this manual before

More information

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube MOS FET Relay in module package with SPDT (1C) This model of operated by voltage (Rated input voltage is 5 VDC.) Contribute to reduce the mounting space on the print circuit board by small package Contact

More information

LIQUIDATOR Electronic Ionization System

LIQUIDATOR Electronic Ionization System LIQUIDATOR Electronic Ionization System Operation and Installation Manual LIQUITECH LIQUIDATOR Series Electronic Controller Unit LIQUITECH Model QLTF Flow Cell LiquiTech, Inc. 421 Eisenhower Lane South

More information

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring Data Sheet 90.7021 Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special

More information

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications 1-50 The Leader in Low-Cost, Remote Monitoring Solutions Wireless AC Voltage Detection Sensor VDC 1-50 VOLT General Description The wireless AC voltage detection sensor can interface with other devices

More information

Instruction Manual STATIC ERASER TOP FAN. Table of Contents

Instruction Manual STATIC ERASER TOP FAN. Table of Contents STATIC ERASER TOP FAN Instruction Manual Thank you for having purchased Stat Clean No. L-90-E Read this instruction manual carefully before use. Keep it in a safe handy place for future reference. Table

More information

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current LED Optimized Drivers 6 Watt Series Model: Series Environmental 6W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive

More information

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop. 897 Safety Sensor SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 Sensor selection guide... P.885~ Korea s S-mark... P.1506 PHOTO PHOTO Conforming to Machinery

More information

Proposal of suitable static control device for your application.

Proposal of suitable static control device for your application. Static Control Devices Selection Guide Proposal of suitable static control device for your application. ER-F SERIES SERIES 2017.04 panasonic.net/id/pidsx/global ER-VS02 Solve your problems caused by static

More information

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc Important Considerations When Selecting a Fan for Forced Air Cooling By: Jeff Smoot, CUI Inc Designing an appropriate thermal management solution requires a systemic approach; each component on a circuit

More information

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL Analox Sensor Technology Ltd 15 Ellerbeck Court Stokesley Business Park Stokesley TS9 5PT Tel: +44 (0)1642 711400 Fax: +44 (0)1642 713900 Email: info@analox.net

More information

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL BULLETIN TB-2095 Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

More information

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Critical Environment Ionizing Blower. Model 5810i. User s Manual Critical Environment Ionizing Blower Model 5810i User s Manual About ION Systems ION Systems develops, manufactures, and markets system solutions to manage electrostatic charge. As the world's largest

More information

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop. 843 Safety Liquid Leak Sensor SQ4 SERIES FIBER PHOTO MICRO PHOTO AREA LIGHT CURTAINS Related Information General terms and conditions... F-17 General precautions... P.1405 Sensor selection guide... P.831~

More information

CONTENTS 1. 1 Ionizing Air Nozzles Overview Benefits Applications... 2

CONTENTS 1. 1 Ionizing Air Nozzles Overview Benefits Applications... 2 CONTENTS 1 Ionizing Air Nozzles Contents 1 Ionizing Air Nozzles 2 1.1 Overview........................................ 2 1.2 Benefits........................................ 2 1.3 Applications......................................

More information

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R en Operation Guide FCS-320-TM Aspirating Smoke Detector Table of Contents en 3 Table of Contents 1 General 6 1.1 Introduction 6 1.2 Safety

More information

DISCHARGING. electrostatic innovations. Top-Class Discharging

DISCHARGING. electrostatic innovations. Top-Class Discharging DISCHARGING Top-Class Discharging DISCHARGING BASIX The optimum choice for many applications The new discharging system Eltex BASIX 100% Eltex at a low price The Eltex discharging technology is suitable

More information

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Overview continues to be the leader in the chemical feed and disinfection of potable water, wastewater and industrial process applications.

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wire Photomicrosensor with Built-in Amplifier (Non-moulate) EE-SX9 Meeting Customer Nees with Compact Sensors that Mount with M Screws Both light- an ark- outputs (antivalent outputs) provie.

More information

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1 DUCTED AIR CONDITIONER Owner s Manual KD Series KD24 Kaden Owner s Manual 1 Table of Contents 1. Safety Precautions 4 2. Indoor Unit Parts and Major Functions 6 3. Care and Maintenance 8 4. Troubleshooting

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

User Guide

User Guide ABS control panel CP 112 212 ON ON ON ON ON ON User Guide www.absgroup.com ii ABS CONTROL PANEL CP 112 212, USER GUIDE Copyright 2008 ABS Group. All rights reserved. This manual, as well as the software

More information

KSIA SERIES SPLIT TYPE ROOM AIR CONDITIONER. For Split Wall Mounted Series R410a Inverter Model Type For F

KSIA SERIES SPLIT TYPE ROOM AIR CONDITIONER. For Split Wall Mounted Series R410a Inverter Model Type For F KSIA SERIES ro le oo SPLIT TYPE ROOM AIR CONDITIONER For Split Wall Mounted Series R410a Inverter Model Type For F KSIA009-H216-I / KSIA009-H216-O KSIA012-H216-I / KSIA012-H216-O KSIA018-H216-I / KSIA018-H216-O

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

Reference Manual. Ionizer Module for XPR Analytical Balances

Reference Manual. Ionizer Module for XPR Analytical Balances Reference Manual Ionizer Module for XPR Analytical Balances Ionizer Module 3 1 Introduction Your Ionizer Module is an accessory for METTLER TOLEDO analytical balances. The ionizer produces a corona of

More information

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN Static Eliminators BFN 802 Ionizing Blower Instruction Manual Contents

More information

EC3-X33 Stand-alone Superheat Controller Technical Data

EC3-X33 Stand-alone Superheat Controller Technical Data Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,

More information

Electrostatic Precipitator

Electrostatic Precipitator Electrostatic Precipitator ESP1500E ESP3000E ESP4500E TECHNICAL & OPERATION MANUAL This manual refers to:- Model ESP1500E Serial No. E152014 Model ESP3000E Serial No. E302014 Model ESP4500E Serial No.

More information

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual Guardian CR2000 Overhead Ionizing Air Blower User s Manual Tabel of Contents SECTION 1: Description SECTION 2: Safety SECTION 3: Features SECTION 4: Specifications SECTION 5: Installation SECTION 6: Operation

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

Wireless Duct Temperature Sensor

Wireless Duct Temperature Sensor The Leader in Low-Cost, Remote Monitoring Solutions Wireless Duct Temperature Sensor General Description The Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft. lead wires to accurately

More information

STATIC ELECTRICITY SOLUTION APPLICATION SHEET

STATIC ELECTRICITY SOLUTION APPLICATION SHEET STATIC ELECTRICITY SOLUTION APPLICATION SHEET EU EU EU De-electrify the product and silicon pad. Usinng a static eraser with a high blow volume could dry out the ink, so using a low or no blow volume

More information

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger. ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

BioZone Scientific International contact information

BioZone Scientific International contact information BEFORE USE Americas BioZone Scientific International contact information Europe 7751 Kingspointe Parkway, Suite 124 Linnoitustie 4 B Orlando, FL 32819 02600 Espoo United States of America Finland Phone:

More information

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet WRF04 CO2 Combined room sensor CO 2 / temperature / humidity 281836 Datasheet Subject to technical alteration Issue date: 26.02.2016 Application Surface mounted sensor for detection of CO2, temperature

More information

Plug-in Base, Long Range Sensor E3B2

Plug-in Base, Long Range Sensor E3B2 Plug-in Base, Long Range Sensor Plug-in Terminal for Easy Maintenance and Installation Universal AC/DC supply voltage Replace sensing head without rewiring Detect shiny objects with polarized retroreflective

More information

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description 24-500 by The Leading Enterprise Internet of Things Solution VOLTAGE DETECT Wireless AC Voltage Detection Sensors (24-500 VAC) General Description The ALTA wireless AC voltage detection sensor can interface

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

E3FA PHOTOELECTRIC SENSORS

E3FA PHOTOELECTRIC SENSORS Authorised Distributors:Intech Systems Chennai Pvt. Ltd, Chennai-6 2 Ph: +91 44 45 8888 Fax: 44 45 888 E-mail: info@intechchennai.com Website: www.intechchennai.com EFA PHOTOELECTRIC SENSORS A new generation

More information

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference.

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. your solution partner Instruction Manual Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents

More information

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors by The Leading Enterprise Internet of Things Solution DUCT TEMPERATURE Wireless Duct Temperature Sensors General Description The ALTA Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft.

More information

E3FA PHOTOELECTRIC SENSORS

E3FA PHOTOELECTRIC SENSORS EFA PHOTOELECTRIC SENSORS A n e w g e n e r a t i o n i n s e n s i n g p e r f o r m a n c e»» S i m p l i c i t y»» O n e fa m i l y fo r a l l»» N o n - s t o p d e t e c t i o n A new generation in

More information

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance

More information

Cable Actuated Sensor Industrial User Scalable 4 20mA

Cable Actuated Sensor Industrial User Scalable 4 20mA Cable Actuated Sensor User Adjustable Stroke Range to 175 inches (3 meters) Easy Push-Button Zero and Span Adjust Designed for Outdoor & IP67 environments In Stock for Quick Delivery! 175-inch model shown

More information

180 Degree Ceiling Mounted Occupancy Sensors

180 Degree Ceiling Mounted Occupancy Sensors Instruction Bulletin 63249-420-386A 2/202 80 Degree Ceiling Mounted Occupancy Sensors PS-CDS800 and PS-CUS800 INTRODUCTION The 80 Degree Ceiling Mount Occupancy Sensors are ideal for use in business and

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series Document No. IZ*-OMP64 C R P r o d u c t Ionizer Model/Series IZS4 Series 1 Contents Safety Instructions... 3 1. How to Order... 9 1-1. Ionizer... 9 1-2. Accessories... 1 1-3. Option... 11 2. Installation...

More information

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver. LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: 7131720 ver.b 1 1 General... 3 2 Features... 3 3 Assembly description...

More information

The World's Longest-distance * Detection

The World's Longest-distance * Detection Proximity Sensors DC 2-Wire Models Series More than double the sensing distance of previous models The World's Longest-distance * Detection Reduces Malfunctions and Collisions * Based on September 2017

More information

SET-2000 Hi Level/Oil

SET-2000 Hi Level/Oil Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

OIL FILM DETECTOR (Flame-proof Version) SODL-1600 OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.

More information

Wireless Light Detection Sensor

Wireless Light Detection Sensor The Leader in Low-Cost, Remote Monitoring Solutions Wireless Light Detection Sensor LIGHT DETECTION General Description The Wireless Light Detection Sensor detects the presence of light. Features Detects

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information