7. ON/OFF Controller (CZ-ANC2)

Size: px
Start display at page:

Download "7. ON/OFF Controller (CZ-ANC2)"

Transcription

1 Control of WAY SYSTEM. / Controller (CZ-ANC). How to Use the / Controller Functions of buttons A : / button C : All button B : All button A: / button Press this to start up or stop an individual air conditioner. B: All button Press this to start up all the air conditioners at the same time. C: All button The indoor s which can be operated by the / now start operating in sequence at intervals of to seconds. Press this to stop all the air conditioners at the same time. - /0/0

2 Control of WAY SYSTEM. / Controller (CZ-ANC) How to use the nameplate The nameplate shows the rooms where the air conditioners are to be operated, and it enables the operating statuses of the air conditioners in those rooms to be checked by the operation indicator lamps. Steps. Insert an implement such as a ballpoint pen into the hole on the left of the transparent cover, and remove the cover.. Use a writing instrument such as an oil-based pen to write the names of the rooms on the switch name labels provided, and adhere the labels to the name displays. - /0/0

3 Control of WAY SYSTEM. / Controller (CZ-ANC). Installation Instructions General This booklet briefly outlines where and how to install the /. Please read over the entire set of instructions for the indoor and outdoor s and make sure all accessory parts listed are with the before beginning. Give these instructions to the customer after finishing the installation. Part Name Figure / Tapping screw Truss-head Phillips x mm Manual For securing the system For installation For operation How to install the / CAUTI For securing the system Install the / at a height of between and. meters above the floor. Do not install the / in a place where it will be exposed to direct sunlight or near a window or other place where it will be exposed to the outside air. Be sure to install the / vertically, such as on a wall. Installation site selection Remarks Rawl plug Q ty Do not twist the control wiring together with the power wiring or run it through the same metal conduit, because this may cause a malfunction. Install the / away from sources of electrical noise. Install a noise filter or take other appropriate action if electrical noise affects the power supply circuit of the. Do not supply power to the or try to operate it until the tubing and wiring to the outdoor is completed. - /0/0

4 Control of WAY SYSTEM. / Controller (CZ-ANC) Overview of the / Unit: mm Electrical component box Control 0 () 0 () Mounting plate (for flush mounting) -Ø diameter holes (for mounting) Control. Electrical component box -Ø. holes for electrical wiring 0 0 Rear plate 0 Hole for electrical wiring -Ø. diameter holes (for mounting) Z-view (back side) Fig. - * In order to mount the / flush with the wall, an opening measuring mm mm is necessary. - /0/0

5 Control of WAY SYSTEM. / Controller (CZ-ANC) Installation procedure Mounting plate Electrical component box a): Normal mounting Rear plate Hole for electrical wiring Fig. - b): Flush mounting. Decide how the / will be mounted: in the normal manner or flush with the wall. a) To mount the / in the normal manner, remove the mounting plate. Then reattach the four screws to the electrical component box. b) To mount the / flush with the wall, make an opening in the wall measuring mm mm. The opening must be at least mm deep as measured from the outside surface of the wall.. Remove the rear plate and connect the electrical wiring. ) Remove the four screws located on both sides of the rear plate. ) Either the hole in the bottom of the electrical component box or the hole in the rear plate may be used to feed the electrical wiring.. Secure the / in place. a) If the / is being mounted in the normal manner, first attach the rear plate to the wall using the screws and Rawl plugs provided. Next, place the body of the / over the rear plate and secure it in place using four screws. b) If the / is being mounted flush with the wall, fit it through the mounting plate on the wall and secure it in place using the screws and Rawl plugs provided. To mount the / on a wall made of cinder block, brick, concrete, or a similar material, drill. mm diameter holes in the wall and insert Rawl plugs to anchor the mounting screws. - /0/0

6 Control of WAY SYSTEM. / Controller (CZ-ANC) Layout of electrical terminals P.C. board C A A A B B B C L U N U Earth for power wiring Connector (CN0) for schedule timer (optional) Clamp for electrical wiring Fig.- How to connect electrical wiring ) Basic wiring N: Power supply (0-0 V 0/0 Hz) L: U: C C U: Inter- control wiring. (Low voltage) (Use shielded wiring) C: Reserve C: Earth for inter- control wiring ) Terminals for remote monitoring A: Input for turning on air conditioners concurrently. A: Input for turning off air conditioners concurrently. A: Common input for turning air conditioners on or off. B: On operation state indicator output. B: Alarm indicator output. B: Common indicator output. / CTROLLER DCV DC voltage pulse Photocoupler input Allowable contact voltage and current : V, 0 ma Pulse width : 00 ms or more A A A COM No-voltage a-contact static output Allowable contact voltage and current : 0 V, 0. A B Digital Input B B - /0/0

7 Control of WAY SYSTEM. / Controller (CZ-ANC) Basic wiring diagram CAUTI Outdoor - Ensure that wiring connections are correct. (Incorrect wiring will damage the equipment.) Outdoor - Outdoor - Ground Outdoor -m Ground m 0 Ground Ground / U U C C N L Ground for control wiring / U U C C Power supply 0/0 Hz) (0-0 V N L Ground for control wiring Ground In.- Power supply 0/0 Hz) (0-0 V Ground In.- Ground In.- In.- Ground Ground n Fig. - In.-n. The following figure is the inter- control wiring. Use the shielded wiring.. In. means indoor.. One / can connect up to two s one main and one sub for each zone. -0 /0/0

8 Control of WAY SYSTEM. / Controller (CZ-ANC) Dip switch setting PCB of the control Dip switch How to reach the P.C. board Remove the flat-top screw on the bottom of the back case. Raise the bottom of the control, and now remove the by sliding it upward. The P.C. board on the back of the control is now visible. Do not force the bottom of the control open. Doing so may damage the notch at the top and make it impossible to install the control. flat-top screw - /0/0

9 Control of WAY SYSTEM. / Controller (CZ-ANC) DIPSW DIPSW Zone address switches Use these to set the zone addresses. (Central Adress (Central Adress (Central Adress (Central Adress -) -) - ) -) / main/sub selection switch This is normally used at the main () setting. When the / is to be used by a main and a sub ( s) in one zone, set one to main () and the other to sub (). : / operates as main. : / operates as sub-. Set the zone address switch of the sub / to the same address as the main /. One / must always be set as the main /. Central control main/sub selection switch (: main, : sub) This is normally used at the main () setting. Set it to sub () when a communication adapter, intelligent or system is to be used concurrently. Group inhibited/all indoor control permitted selection switch Use these to switch between the group inhibited and all indoor control permitted statuses for each of the four groups. All indoor control permitted - Group inhibited - Group inhibited - Group inhibited - Group inhibited All indoor run/stop selection switch Use this to select the s to be run or stopped when the ALL. or ALL.O button has been pressed. : All indoor : inhibited indoor * All switches are position at shipment. - /0/0 Fig. -

10 Control of WAY SYSTEM. / Controller (CZ-ANC) Zone address setting The zone addresses must be set (using # and # of DIPSW) when the / s are to be controlled in a multiple number of zones. Set to zone when the / is to be used in one zone only. When the / s are to be used in a multiple number of zones, one of them must be set to zone without fail. ZE ZE central control address - ZE ZE central control address - ZE ZE central control address - 0 ZE Fig. - ZE central control address - - /0/0

11 Control of WAY SYSTEM. / Controller (CZ-ANC) How to perform zone registration To operate the / properly, zone registration is required after finishing the test run (and after setting all indoor addresses)using one of the following methods. (a) Zone registration using the remote Refer to page - (b) Zone registration using the system Refer to page - (c) Automatic zone registration using the system Refer to page - For methods (a) and (b), you should make a zone registration table manually before performing the registration as shown on the page -0. For method (c), zone registration is executed automatically, proceeding from small indoor address and small central addresses to larger numbers in numerical order. For example: Central address ZE-group address An indoor address is assigned to each indoor during automatic address operation. Each indoor address combines an R.C. address and indoor number as follows: : address (UNIT No.) No. Refrigerant circuit No. (R.C. address) This address is displayed on remote for UNIT No. when the UNIT button is pressed.. The central address represents the zone and group number. These addressed are assigned in ascending numerical order. - /0/0

12 Control of WAY SYSTEM. / Controller (CZ-ANC) ZE registration table ZE DIPSW DIPSW GROUP Central address address (UNIT No.) Unit location GROUP Central address ZE DIPSW DIPSW address (UNIT No.) Unit location. Assign indoor addresses to the desired positions (central addresses) manually.. For group control, only the main indoor should be assigned. Sub indoor s cannot be assigned. - /0/0

13 Control of WAY SYSTEM. / Controller (CZ-ANC) (a) Zone registration using the remote (Determination of central address) In this case, after confirming which indoor is connected to the remote and that the air conditioner in the state, you set the central addresses one at a time. If the system has no remote, connect a remote to the system temporarily. Then follow this procedure. The indoor address must already have been set before performing zone registration. If necessary, refer to the Installation Manual supplied with the outdoor. () Press the and buttons at the same time of the remote for more than seconds. () Do not press () Once in this mode, the UNIT No., CODE No., No. of SET DATA and indications will flash on the display as shown Fig. -. In case of group control "ALL" instead of "UNIT No." will flash on the display. Select the main indoor address by pressing the button once. () Set CODE No. to 0 using the buttons. and Fig. - CODE No. 0 must be selected to perform zone registration using the remote. () Set the Central address which you want to assign to the and buttons indoor address using the according to the zone registration table. () Press the The CODE No. and Central address changes from flashing to state. If you make a mistake, button and reset the central address. then press the () Press the button to finish zone registration. For example, in this case address:- Central address : (ZE, GROUP ) Fig /0/0

14 Control of WAY SYSTEM. / Controller (CZ-ANC) (b) Zone registration using the system In this case, you set all Central addresses by system at once manually. If no data is registered, no number is displayed. () Press the and buttons at the same time for more than seconds. and CODE No. C will flash. () After confirming that CODE No. C is displayed, press the Once in this mode, a change takes place as Fig. -. () Select the zone and group No. which you want to set with and (GROUP) buttons. If already set, press the buttons. If data is registered the No. is displayed. and () Set the No. ( address) with buttons, according to the zone registration table. R.C. No..... button No..... button Selected group No. if no data is registered. Fig. - () Press the GROUP No. turns and UNIT No. ( address) changes from flashing to state. UNIT No. is registered to selected ZE No. and GROUP No. If you make mistake, then press the button and reselect the ZE, GROUP and UNIT No. () Register the other UNIT No. in the same way by following the steps () to (). () Finally, complete the registration by pressing the flashes for a few minutes, then. For example, in the case at left Zone, group No. Unit No. (indoor address) - Unit No. - is registered to zone -group. Fig. - - /0/0

15 Control of WAY SYSTEM. / Controller (CZ-ANC) (c) Automatic zone registration using the system and buttons at the same time for more than () Press the seconds. and CODE No. C will flash. and ( ) button () Select CODE. No. C by pressing and press the C changes from flashing to state and automatic zone registration will start. () Registered GROUP No. will be disappeared all. () Central address will be assigned from small indoor address to large one in numerical order automatically. Finishing automatic zone registration, changes from flashing to. () If the error is happened, the CHECK starts flashing and zone registration finishes at this time. Press the () Finally, complete automatic zone registration mode by pressing the flashes for a few minutes, then. - /0/0 Fig. -

16 Control of WAY SYSTEM. / Controller (CZ-ANC) How to check overlapping of central address no. () Press the and buttons at the same time for more than seconds. and CODE No. C will flash. () Select CODE No. C by pressing, press the C changes from flashing to state and auto overlap checking will start. ( ) button and will flash. Then () If C changes from to flashing and stops flashing and disappears, there is no overlapping. Then finally, complete the auto overlap checking mode by pressing the () If some of GROUP No., ZE No. and UNIT No. flash, you should try again the zone registration. Select CODE No. C by pressing, ( ) button and press the Select the flashing GROUP No. with ZE and GROUP Then press the button and reselect the ZE, GROUP and UNIT No. Then finally, complete the auto overlap checking mode by pressing the Fig. - - /0/0

17 -0 /0/0 - Central address - Group control Connection wiring for group control - - Inter- control wiring (shielded wiring) - Standard control - (Sub) - Multiple remote control (Main) () For a system without link adress : (No need setting) Inter- control wiring Inter-outdoor- control wiring (shielded wiring) (shielded wiring) Connection wiring for central control (shielded wiring) / Out door (Sub) Out door (Main) Control of WAY SYSTEM. / Controller (CZ-ANC) System examples The following diagrams show system examples and the correct setting of the switches on the PCB.

18 DIPSW - /0/0 DIPSW adress (No need setting) Central address (Zone-Group) Zone registration (*) ZE ZE / / Group control R.C. (Sub) - (-) - (-) Connected with outdoor A = Zone R.C. (Main) R.C. - (-) - (-) Group control R.C. - (-) R.C. (Sub) (-) - (-) - Multiple remote control R.C. (Main) Outdoor B (Sub) Connected with outdoor B = Zone Outdoor B (Main) Standard control R.C. Inter- control wiring (shielded wiring) Control wiring indoor & outdoor (shielded wiring) Outdoor A (Sub) * Regarding the zone registration for /, please refer to Installation manual of /. - (-) Outdoor A (Main) Control of WAY SYSTEM. / Controller (CZ-ANC) () For a system with link

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH COMPLIANT MANAGER Model name: BMS-CM1280TLE BMS-CM1280FTLE Save These Instructions! ENGLISH Contents 1 PRECAUTIONS FOR SAFETY........................................... 3 2 PACKAGED ITEMS OF COMPLIANT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

TEST RUN SERVICE MANUAL

TEST RUN SERVICE MANUAL TEST RUN SERVICE MANUAL Model No. Outdoor Unit ME Class Model Name HP U-MEE 0HP U-0MEE HP U-MEE HP U-MEE HP U-MEE HP U-MEE 0HP U-0MEE U-MEEE U-0MEEE U-MEEE U-MEEE U-MEEE U-MEEE U-0MEEE Indoor Unit Class

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 05-355 KMS0772_indoor 3/16/06 5:27 PM Page a INSTALLATION INSTRUCTIONS Inverter Split System Air Conditioner COOL/ DRY Model This air conditioner uses the new refrigerant R410A. For Indoor Unit Contents

More information

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation and user manual for the BiWire / Conventional Repeater Panel Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....

More information

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER 24V Thermostat Interface Model name: TCB-IFTH1GUL FOR INSTALLER Read this manual before using the TCB- IFTH1GUL 24V Thermostat Interface. Refer to installation manuals supplied with Indoor Unit, Remote

More information

Quick Reference. for Remote Countroller

Quick Reference. for Remote Countroller A1C-1405 Quick Reference for Remote Countroller Digital Inverter (DI) Super Digital Inverter (SDI) MiNi-Super Modular Multi System (MiNi-SMMS) Super Modular Multi System (SMMS) Super Modular Multi System-i

More information

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA TECHNICAL & SERVICE MANUAL STK-RCS-7TWSUA FILE NO. Destination: North America WIRED REMOTE CONTROLLER Model No. STK-RCS-7TWSUA Product Code No. 1 852 353 85 REFERENCE NO. SM700799 Important! Please Read

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English EH99862001-2 AIR CONDITIONER (SPLIT TYPE) Installation manual Branch kit 1:3 Model name: RBC-TRP100E Installation manual Air conditioner (Split type) 1 English Please read this Installation Manual carefully

More information

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

ignored. Denotes content that may result in bodily injury and physical damage when ignored. SC-201-12M, SC-201-24M Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are critical

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

RES-210 (-211, -220, -221) / RES-420

RES-210 (-211, -220, -221) / RES-420 RESISTR GB Replacing RES-2xx/ Replacement Instructions The RESISTR temperature controller can be used as an alternative to the following controllers of the series 200 : RES-210: Analog temperature display,

More information

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

RTD-10 Installation Instructions

RTD-10 Installation Instructions LED3 SW1 LED4 LED5 LED6 RTD-10 Installation Instructions +V S5 S6 POWER 15-24VDC English RTD-10 Installation Instructions 100.00 RTD-10 Control Interface realtime Control Systems 24VAC/3DC, 1A REMC P1

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS NOTE: Set up for this sensor should be performed by an AAADM-certified installer. Section 1 General Description The DHR3 is a combination microwave/infrared sensor providing both motion detection and presence

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

Installation and Owner s Manual

Installation and Owner s Manual WIRED REMOTE CONTROLLER Installation and Owner s Manual MODEL: KJR-120G1/TFBG-E(5V)(For high wall models) KJR-120G2/TFBG-E(12V) (For Duct/Cassette/Floor ceiling models) IMPORTANT NOTE: Read this manual

More information

DEMA 844 Laundry Master Laundry Chemical Dispensing

DEMA 844 Laundry Master Laundry Chemical Dispensing DEMA 844 Laundry Master Laundry Chemical Dispensing Overview The DEMA Laundry Master is a digital laundry dispenser designed to dispense chemicals when signals are received from commercial laundry machines.

More information

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E FLOW TEMP. CTROLLER 2B (Cased) PAC-IF032B-E INSTALLATI MANUAL FOR INSTALLER For safe and correct use, read this manual thoroughly before installing the unit. English OPERATI MANUAL FOR USER For safe and

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

Intelligent cascading kit

Intelligent cascading kit Technical Service Instruction Intelligent cascading kit Kit components: Cascading cable (2X) 6720811759 / 238-51036-00A (2014/05) Table of contents Table of contents 1 Key to symbols and safety instructions............

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Solenoid Valve Kit For 3WAY VRF System CZ-PXXXHR3 () IMPORTANT! Please Read Before Starting This solenoid Valve kit must be installed by the sales dealer or installer. This information

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series Premier Series MODEL 5000 USER MANUAL 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including

More information

Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication

More information

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value) RESISTRON GB Replacing / Replacement Instructions The RESISTRON temperature controller can be used as an alternative to the older controller type. The mechanical outlines are identical. The connection

More information

Installation and Owner s Manual

Installation and Owner s Manual WIRED REMOTE E CONTROLLER Installation and Owner s Manual MODEL: WC 20G Mode - + Fan speed (Lock) IMPORTANT NOTE: Read this manual carefully before installing or operating your wired remote controller.

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E FLOW TEMP. CTROLLER 2B (Cased) PAC-IF032B-E INSTALLATI MANUAL FOR INSTALLER For safe and correct use, read this manual thoroughly before installing the unit. English OPERATI MANUAL FOR USER For safe and

More information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Inverter Split System Air Conditioner COOL/ DRY Model This air conditioner uses the new refrigerant R40A. Refrigerant service valve size = 5/6" Contents Page Model Combinations

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

AURATON 2005 / 2005 TX

AURATON 2005 / 2005 TX AURATON 2005 / 2005 TX USER MANUAL PP LARS 2003 Thank you for purchasing the AURATON 2005. Your new programable thermostat will serve your family for years and significantly save the energy cost. The large

More information

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat MODEL 2000NC USER MANUAL Builder Series 5-2 Day Programmable Single Stage /Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CDITIERS - SET-FREE SERIES - Type In-the-Ceiling (Duct) Model RPI-3.0FSN2SQ RPI-4.0FSN2SQ RPI-5.0FSN2SQ RPI-6.0FSN2SQ

More information

Set & $ave. Model Programmable Thermostat. installation and operation manual

Set & $ave. Model Programmable Thermostat. installation and operation manual Set & $ave Programmable Thermostat installation and operation manual Model 44110 42707-01 8-21-06 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling the Existing Unit... 7 Installing

More information

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models CEILING CASSETTE TYPE, HEAT PUMP AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH483 Ceiling cassette type Models E1 MLZ-KA25VA - E1 MLZ-KA35VA - MLZ-KA50VA - E1 Outdoor unit service manual MXZ-A VA Series

More information

Infrared Moisture Determination Balance FD-610. Operating Manual

Infrared Moisture Determination Balance FD-610. Operating Manual Infrared Moisture Determination Balance FD-610 Operating Manual Infrared Moisture Determination Balance Safety Notes Improper use of the infrared moisture tester in violation of the following safety notes

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

Clock Radio AJ100. User manual

Clock Radio AJ100. User manual Clock Radio AJ100 User manual 1 1 2 5 6 3 4 7 8 9! @ # $ % 0 ^ 2 3 4 English SUPPLIED ACCESSORIES 1 X AC 7.5V adapter (Input: 220-230V ~ 50Hz 30mA, Output: 7.5V 250mA) TOP AND FRONT PANEL (See 1) 1 REPEAT

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC020230 (208-230V) 24V Interface Kit for Ductless Outdoor Single Zone matched with Air Handler Installation Instructions Read and become familiar with these instructions before beginning installation.

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

mtc001 Thermocouple Converter

mtc001 Thermocouple Converter THERMOCOUPLE CONVERTER 1-WIRE INTRINSICALLY SAFE mtc001 mtc001 Thermocouple Converter Document No. 10789, Revision A February 2007 2006 CMC Industrial Electronics Ltd. This page intentionally left blank.

More information

Greentrol Automation, Inc.

Greentrol Automation, Inc. Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000

More information

Beacon 410A Gas Monitor Operator s Manual

Beacon 410A Gas Monitor Operator s Manual Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

15. Installation. For 6.2ton and above

15. Installation. For 6.2ton and above 15. Installation 15.1 Lifting Rigging cables should have adequate capability to resist 3 times weight of unit. Before lift, please check and ensure that hooks are holding tightly to unit and lifting angles

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT) Manual No. '4 KX-SM-202 SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS (OUTDOOR UNIT) KXZ series (Heat pump type) Standard series Single use (Used also for combination) FDC280KXZE, 335KXZE,

More information

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10 Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES Middle Static Pressure Duct Type KDIR SERIES Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.

More information

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.

More information

ENGLISH. Recirculation with On-Demand Accessories User Guide 1

ENGLISH. Recirculation with On-Demand Accessories User Guide 1 ENGLISH Recirculation with On-Demand Accessories User Guide 1 This manual provides detailed information on Rinnai s on-demand recirculation accessories; it is designed for field installers and is a supplement

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

CONTENTS BEFORE YOU BEGIN

CONTENTS BEFORE YOU BEGIN Owner s Guide Wood Blinds Alternative Wood Blinds 2" Aluminum Horizontal Blinds Intelligence Interface Motor Clip Receiver Eye Battery Holder Battery Cover Remote PowerTilt Motorized Tilt System CONTENTS

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLS ASURLS ASU5RLS AOU9RLSH AOURLSH AOU5RLSH R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Constant voltage 3-phase rectifier.

Constant voltage 3-phase rectifier. 11750a Constant voltage 3-phase rectifier. Page 1 of 11 11750a Mechanical assembly The rectifier is assembled in a cabinet intended for indoor wall mounting. The cabinet has ventilation holes on both sides

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Service Manual Indoor AW09ESVHA AWESVHA AW8ESVHA AWESVHA Outdoor U09ESVHA UESVHA U8ESVHA UESVHA Design may vary by model number. Please read this manual before using the

More information

INSTALLATION INSTRUCTION for ceiling fan

INSTALLATION INSTRUCTION for ceiling fan INSTALLATION INSTRUCTION for ceiling fan F8203 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual Motor is core parts of the fan and the most expensive in all the components.

More information

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models Revision D: MSZ-FH25VE2- E1, ER1, MSZ- FH35VE2- E1, ER1 and MSZ- FH50VE2- E1, ER1 have been added. Please void OBH623 REVISED EDITION-C. INDOOR UNIT SERVICE MANUAL. OBH623 REVISED EDITION-D Models MSZ-FH25VE

More information

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52 Error Codes: Outdoor Units Error Codes: Outdoor Units Part. What Is in This Chapter? Introduction Overview In the first stage of the troubleshooting sequence, it is important to correctly interpret the

More information

Programmable Thermostat

Programmable Thermostat Set & $ave Programmable Thermostat Installation and Operation Manual English Model 44360 Form# 42710-01 20091204 2009 Hunter Fan Co. 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling

More information

BC-R10 Series. Burner Controllers

BC-R10 Series. Burner Controllers No. CP-SS-1885E BC-R10 Series Burner Controllers Summary BC-R10 Series burner controllers are combustion safety controllers specifically designed for batch operation (systems which start and stop at least

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000PC SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing IMPORTANT : PLEASE READ BEFORE INSTALLATION.. Do not connect this remote

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC005 (5V) KSAIC00230 (208-230V) 24V Interface Kit for Ductless Systems Installation Instructions Read and become familiar with these instructions before beginning installation. SAFETY CSIDERATIS Read

More information

Simple Self-Diagnosis by Malfunction Code

Simple Self-Diagnosis by Malfunction Code Detail Division 0 Indoor Unit System Others A C E F H J L P U M 7 8 9 External device activated (unified) Protection devices activated (unified) of Miswiring of Shortage of amount ( unit) Shortage of External

More information

MD12-2 Vehicle Loop Detector

MD12-2 Vehicle Loop Detector MD12-2 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions Bulletin E-97DC Thank you for purchasing the Dwyer DCT1000DC Dust Collector Timer Controller. You

More information

QA16 Addressable System

QA16 Addressable System QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.

More information

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Installation and Operation Manual For Hunter Ceiling Fans /16/2004 Installation and Operation Manual For Hunter Ceiling Fans 1 2 CONGRATULATIONS! Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years.

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Inverter Split System Air Conditioner COOL/ DRY Model This air conditioner uses the new refrigerant R410A. Contents Page Model Combinations IMPORTANT! Please Read Before Starting...

More information

Digital Programmable

Digital Programmable www.geappliances.com Digital Programmable Thermostats Operating Instructions Auto Changeover..........10 Day/Time Setting Mode.....6 Default Mode...............4 Fan Control...............10 Hold and Temporary

More information