1 SDR-WEXT Wired Siren Installation Guide The SDR-WEXT is an external siren and strobe unit designed for use with i-on, Menvier and other third-party control units. The siren uses fixed wiring between itself and the control unit or expander. Two models of the siren are available: SDR-WEXT-G2 (for EN grade 2 applications) SDR-WEXT-G3 (for grade 2 or 3 applications) The SDR-WEXT-G3 contains all features provided by the SDR-WEXT-G2, together with several additional features for enhanced monitoring and system testing. Key Features Easy to install 100 db(a) sound output High-power comfort LEDs High-power LED strobes Selectable SCB or SAB mode Built-in spirit-level Self-supporting lid for ease of installation Revolving fixing holes Engineer (quiet maintenance) mode Lid and rear tamper detection Selectable cut-off timer Choice of siren tones Impact-resistant polycarbonate construction Additional Features for the SDR WEXT G3 The SDR-WEXT-G3 provides the following additional features: Remote self-test input Built-in microphone for sounder fault reporting Optional battery fault reporting Optional monitoring of tamper conditions on Bell (Trigger) input Selectable voltage and termination for tamper return Note: When using the SDR-WEXT-G3 with an i-on/menvier control unit, make sure that the control unit has firmware version 4.05 or later. Page 1
2 Table of Contents Installing the Siren 2 Quick Reference 4 Connections to Other Control Units 5 Connection Details 6 TR 6 ENG (Installer Mode) 6 STR and BELL 6 F-F and F-R and RST 6 TF 7 PCB Jumper Details 7 SCB/SAB 7 Trig Mon 7 Tone Slct 7 Time 7 LED En 7 Tmp Feed 8 Fault and Tamper Monitoring 8 Summary of Strobe Operation 8 Maintenance 8 Cable Recommendations 9 Specifications 9 Installing the Siren Step 1 Choose a Location for the Siren Choose a location that is: Out of reach of intruders and vandals. Easily visible for maximum deterrence. Within the allowable cable distance (see Cable Recommendations on page 9). Step 2 Open the Lid of the Siren 1. With the siren not yet fixed to the wall, open the hinged cover that gives access to the lid-retaining screw (see Figure 2). 2. Loosen the screw and open the lid. Step 3 Configure the Siren Jumpers 1. Remove the link/terminal cover (see Figure 2) by pushing the two retaining tabs to the side of the unit while lifting the cover. 2. Set all jumpers in the siren to the required positions (see Quick Reference on page 4). Step 4 Disconnect all Power Make sure that all power to the control unit is disconnected, including the backup battery. Also make sure that the battery in the siren is not connected. Step 5 Install Cabling Install all cabling between the control unit/expander and siren (see Cable Recommendations on page 9). Connect the cabling at the control unit/expander end, but leave the siren unconnected for now. Note: To prevent water ingress, cables must enter the cable-entry hole at the siren (see Figure 2) from below. Step 6 Attach the Siren to the Wall 1. Position the siren against the wall using the built-in spirit level to assist levelling, and mark all four fixing points. 2. Drill and plug the fixing points using the screws and plugs provided. 3. Pass wiring through the cable-entry hole. 4. Screw the siren to the wall. Use the spirit level and revolving guides to correct any misalignment. Step 7 Connect the Siren Wiring, Power Up and Close the Lid Note: The sounder should not activate during the following process. However, be prepared in the event that it does activate; make sure that any very loud noise produced cannot cause a fall. 1. Connect all wiring to the siren (see Quick Reference on page 4). 2. Connect the siren battery (see Figure 1). Page 2
3 Figure 1: Battery Connector The siren should power up in "silent startup" mode, which is indicated by the comfort LEDs remaining solidly lit. 3. Re-fit the jumper/terminal cover, close the lid, tighten the lid-retaining screw and close the screw cover. (The LEDs will remain solidly lit and the siren will not go into normal mode until power is applied to the control unit.) Step 8 Power-up and Configure the Control Unit 1. Connect the backup battery in the control unit. 2. Switch on power to the control unit. A siren tamper alarm may be indicated. 3. Configure the control unit. If you are using an i-on or Menvier control unit, you need to carry out the following for the siren: a) If you are using the ENG input: Installer Menu Outputs Radio/Wired Outputs Panel/Exp<nn>-<nn> <output number> Type Installer on Site. b) To set the termination for the TR terminal (SDR-WEXT-G3 only): Installer Menu System Options Panel Tamper Rtn. c) If you are using the RST input (SDR-WEXT-G3 only): Outputs Radio/Wired Outputs Panel/Exp<nn>-<nn> <output number> Type Remote Self- Test. 4. Fully test the system. Spirit level Tamper switch Cover retaining tab (pull tab each side to release cover) Cable entry hole Battery Cable entry hole Revolving fixing hole (1 of 3) Hinged cover for lid-retaining screw Link/terminal cover Figure 2: SDR-WEXT Wired Siren Page 3
4 See next page Quick Reference Jumper Settings (see PCB Jumper Details for further information). Trig Mon (G3 only): Fit the link to monitor for tampers at the BELL input Tone Slct: Fit the link or leave open to select the sounder tone Tmp Feed (G3 only): Determines the voltage and termination of TR Figure 3: Jumper Settings SAB/SCB: Choose the mode Time: Choose the sounder cut-off period LED En: Fit the link to enable the comfort LEDs Typical Connections The following connections are for i-on and Menvier systems; see Table 1 for connections to other control units. See also Connection Details for further information. Output of type "Remote Self Test" Zone of type "Ext WD Fault" (see note) Optional battery/fault reporting for grade 3 only. Enable Remote Self Test in the Siren menu to use these connections. Note: For F-F/F-R, ensure that resistors are fitted at the siren end, depending on the supervision level configured at the control unit. Also, instead of connecting F-R and F-F to a zone of type "Ext WD Fault", you can connect them to TRB and 0V respectively in an i-on1000 or Menvier1000. Output of type "Installer on Site") STB/STR (or output of type "Strobe") BELL/Trigger (or output of type "Siren") +12V 0V Figure 4: Typical Connections Page 4
5 Tamper Monitoring Choose one of the following connection options. Note: If you are using the SDR-WEXT-G3, also configure the Tmp Feed jumper, depending on the option used (see page 8). OPTION 1: Connect to a dedicated TR terminal at control unit. OPTION 2: Connect to a zone* of type "Tamper Return". In i-on/menvier systems, TR should connect to the non-zero-volt terminal of the zone (i.e. next to the "Z" on the terminal label); leave the other terminal of the zone unconnected. Connect to zone* configured as type "Tamper Return". OPTION 3 (grade 3 only): *If the zone contacts are 4-wire CC, use the tamper contacts and link the alarm contacts. Figure 5: Tamper Monitoring Connections to Other Control Units Table 1 shows how to connect the SDR-WEXT to control units not manufactured by Eaton. SDR-WEXT TR STR BELL + 0V C&K Active 5, Securit 24 Tamper ST- S- BELL+ AUX- Sterling 10 BT STB NO Bell NO BELL+ BELL- Matrix BT PGM2 (No) PGM1(No) AUX+ AUX- PCX Euro 1 TR PGM2/STB PGM1/BELL Aux+/B+ Aux-/B- ADE T STROBE- B D A Texecom C S B A D GE 270R TR STROBE- EXT BELL- BELL+12V BHO Risco/Gardtec SCBP -STB BELL BELL+ SCBA DSC Range ZONE PSM1 BELL- BELL+ AUX- Table 1: Connections to Other Control Units Page 5
6 Connection Details TR The TR terminal provides the control unit with the tamper status of the siren. TR is activated (and the siren self-activates) if any of the following occurs: a) The siren's tamper switch is activated. b) The BELL input from the control unit/expander is cut, providing the Trig Mon link (page 7) is fitted (SDR-WEXT- G3 only). c) Power from the control unit/expander is disconnected. When using the SDR-WEXT-G2, TR is taken directly to 0V when a tamper is detected. When using the SDR-WEXT-G3, the voltage and termination of the TR terminal must be configured using the Tmp Feed jumper (see page 8). ENG (Installer Mode) Setting the ENG input to 0V sets the siren in installer (engineer) mode. You should normally connect ENG to a control unit/expander output configured as type "Installer on Site", which activates when entering the Installer menu at a keypad and deactivates when exiting the Installer menu (at every keypad). Installer mode prevents the sounder and strobe from activating when the lid is opened. When installer mode is activated, both comfort LEDs switch on continuously for a few minutes. STR and BELL 0V at the STR (strobe) input activates the strobe. 0V at the BELL (trigger) input activates the sounder. Some control units provided dedicated strobe and bell outputs. If not (or an expander is used), connect to outputs of type "Strobe" and "Siren" respectively. F-F and F-R and RST The SDR-WEXT-G3 provides F-F (Fault Feed) and F-R (Fault Return) volt-free terminals, which are used to provide sounder and battery fault reporting to the control unit. To enable sounder and battery fault reporting, see Quick Reference on page 4 for connection and configuration details. Technical Detail for Advanced Installers The siren tests the battery voltage under load conditions every hour and when the ENG input is deactivated. The sounder is tested each time it is activated. Under normal conditions, F-F and F-R are closed circuit. If either test fails, F-F and F-R go open circuit, which causes the control unit to generate an alarm. The contacts remain open circuit until the test is successful or the siren's tamper switch is activated (in the latter case, the siren assumes that an engineer is fixing the problem). A sounder or battery fault may prevent the system from being set (depending on grade) and cannot be cleared until the siren's tamper switch is activated, or the test is performed again and passes. You can start a test manually by using the Installer Menu Test Sirens & Sounders Wired Sirens Remote Self-Test, which tests both the sounder and battery. When Remote Self-Test is used, the RST (Remote Self-Test) input is set to 0V for the duration of the test. This causes F-F and F- R momentarily to go open circuit, which confirms to the control unit that the siren is healthy. If the siren passes, F-F and F-R go closed circuit (normal state) within 60 seconds. The siren fails the test if the contacts remain open after 60 seconds or if the control unit does not detect the open circuit at the start of the test. A remote self-test occurs only when RST is 0V; setting RST to 12V or leaving it unconnected disables remote self-test. Page 6
7 TF The SDR-WEXT-G3 has a TF (Tamper Feed) terminal, which should be used only if a Tmp Feed link is not fitted. TF and TR go open circuit on a tamper condition; the normal state is open circuit. PCB Jumper Details SCB/SAB Trig Mon In SAB (Self-Activating Bell) mode, which is the typical choice, the siren draws all its power from the control unit/expander. The internal battery is used only if power from the control unit/expander is disconnected. In SCB (Self-Contained Bell) mode, all power to operate the siren when in a non-alarm state is drawn from the control unit/expander. When in an alarm state, the siren sources power from its own internal battery. Typically, SCB mode is used if the control unit/expander is not able to provide sufficient power (e.g. if multiple sirens are used). The SDR-WEXT-G3 has a Trig Mon (Trigger Monitor) jumper. Fitting a link allows the siren to monitor the BELL input for tamper conditions (e,g, caused by the wire being cut). If a BELL tamper condition is detected, the sounder and TR output activate. The output at the control unit/expander end of the cable requires a 4k7 pull-up resistor (between the output and 12Vdc ). This is provided by default if you are using an open-collector transistor output from an i-on, Menvier or Scantronic control unit/expander (such as provided by the BELL output). If a relay-type output is used, you need to add the resistor yourself. If you are using an open-collector output from another type of control unit and want to check for the presence of a 4k7 pull-up, temporarily connect a separate 4k7 resistor between the output and 0V; if a 4k7 resistor is present, the voltage at the output should be half of the supply voltage to the siren (typically 6.9Vdc). The jumper setting is read when power is applied or the lid is opened. Tone Slct Fit a link across Tone Slct (Tone Select) or leave it disconnected to choose one of two tones from the sounder. You may want to use this feature if, for example, you want to be able to distinguish two sounders that are in close proximity. Time The Time (Cut-Off Timer) jumper configures the maximum length of time the sounder operates following an alarm (even if the BELL input is still active). Choose 5 seconds, 3 minutes or leave the link disconnected for a default cut-off time of 15 minutes. Note: To reactivate the sounder, the BELL input must be taken to 12V for at least two seconds before 0V is reapplied. The jumper setting is read when power is applied or the lid is opened. LED En Fit a link across LED En (LED Enable) to enable the comfort LEDs. The jumper setting is read when power is applied or the lid is opened. During normal operation, the comfort LEDs flash alternately when the siren has power connected to give a visual indication that the system is operational. When installer mode is activated, both comfort LEDs switch on continuously for a few minutes. The comfort LEDs also switch on continuously during the silent startup period between connecting the battery and 10 seconds after closing the lid. Page 7
8 Tmp Feed The SDR-WEXT-G3 contains a Tmp Feed (Tamper Feed) jumper, which determines the voltage of the TR terminal and how the sounder terminates TR, as described next. EOL Setting Use the "eol" setting if: This setting ("eol") causes TR to connect to 0V through a 2k2 on-board resistor. You connect TR to a dedicated bell/strobe TR input at the control unit, and the input is programmed (see Note 1) to use FSL wiring. Note 1: In i-on/menvier systems, using Installer Menu System Options Panel Tamper Rtn. "-" Setting Use the "-" setting if: This setting ("-") causes TR to connect directly to 0V. You connect TR to a dedicated bell/strobe TR input at the control unit, and the input is programmed (see Note 1 above) to use CC wiring. You connect TR to a zone that is configured as type "Tamper Return". "+" Setting "No link" Setting This setting ("+") causes TR to connect to 12V through a 1k0 on-board resistor. This may be required for third-party panels. When no link is fitted, TR connects directly to TF. Use the "no link" setting if: You connect TR and TF to a zone configured as type "Tamper Return". You wish to fit an alternative in-line resistor of your choice between TR and 12V/0V. Fault and Tamper Monitoring The siren monitors the following: Tamper conditions All tamper conditions reported by the TR terminal (see page 6) are continuously monitored. The siren self-activates on a tamper. Battery voltage (SDR-WEXT-G3 only) The siren monitors the battery voltage under load conditions and reports a fault during a remote self-test and at other times (see page 6). Sounder operation (SDR-WEXT-G3 only) If the F-R output is used, the siren checks that the sounder is audible during a remote self-test (see page 6) and when operated. Summary of Strobe Operation The strobe operates if the siren selfactivates or if the control unit/expander sets the STR input to 0V. After 15 minutes of the siren being activated, the strobe flashes at a slower rate until the alarm is reset. In i-on/menvier systems, the strobe can also be configured using the Set Conf link and the Strobe on Set/Unset options (see "PCB Jumper Details"). Maintenance NOTE: Start installer mode (page 6) before opening the lid of the siren. This should prevent the sounder from activating. However, be prepared in the event that the sounder does activate make sure that any very loud noise produced cannot result in a fall. During routine maintenance, test the siren for correct operation, carry out a remote self-test (see page 6), check the tamper switch and for any signs of water or insect ingress and clean as necessary. Page 8
9 NOTE: Equipment must be disposed of in accordance with WEEE regulations and any other local or national regulations. Cable Recommendations Standard 7/0.2 un-screened alarm cable should be used. The maximum recommended cable distance is 50m if you are using SAB mode and only TR for tamper monitoring (i.e. not both TR and TF). This can be increased to 100m by doubling the 0V cores. The maximum recommended cable distance is 100m if you are using SCB mode, or both TR and TF for tamper monitoring. Specifications Current consumption: 35mA quiescent current including battery charge and comfort LEDs. 225mA in-alarm current (in SAB mode) Sound Output: 100 db(a) IP Rating: IP65 Strobe Frequency: approx 1Hz Case Material: Polycarbonate Intrusion Standards: PD6662:2010, EN :2009 EN Grade: Grade 2 (SDR-WEXT- G2), or Grade 3 (SDR-WEXT-G3) Environmental Class: Class IV EU Compliance Standards: R&TTE: 1999/5/EC, EMC: 2004/108/EC, RoHS: 2011/65/EC, WEEE: 2012/19/EC, EUP: 2005/32/EC, Low voltage: 2006/95/EC, General safety: 2001/95/EC Weight: 1.2kg Operating Temperature Range: -25 C to +60 C Max Relative Humidity: 95% Dimensions: 290mm (h) x 277mm (w) x 80mm (d) This product must be installed by qualified service personnel. Page 9
10 NOTES Page 10
11 NOTES Page 11
12 Eaton s Security Business IN NO EVENT WILL EATON S SECURITY BUSINESS BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INDIRECT LOSS OR DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES, LOSS OF PROFITS, LOSS OF REVENUE, LOSS OF ANTICIPATED SAVINGS, LOSS OF BUSINESS OR OPPORTUNTIY, LOSS OF GOODWILL OR INJURY TO REPUTATION, LIQUIDATED DAMAGES OR LOSS OF USE, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. EATON S SECURITY BUSINESS S LIABILITY FOR DAMAGES ARISING OUT OF OR RELATED TO A PRODUCT SHALL IN NO CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT FROM WHICH THE CLAIM ARISES. TO THE EXTENT PERMITTED BY APPLICABLE LAW, THESE LIMITATIONS AND EXCLUSIONS WILL APPLY WHETHER EATON S SECURITY BUSINESS S LIABILITY ARISES FROM BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING BUT NOT LIMITED TO NEGLIGENCE), STRICT LIABILITY, BY OPERATION OF LAW, OR OTHERWISE. Every effort has been made to ensure that the contents of this book are correct. The contents of this book are subject to change without notice. Eaton, Security House, Vantage Point Business Village, Mitcheldean, GL17 0SZ. Product Support (UK) Tel: +44 (0) available 08:30 to 17:00 Monday to Friday. securitytechsupport@eaton.com Part number Issue 2, 28/01/16 Page 12
AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren
AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren EN Installation instructions and user guide Version 1.0 Contents Introduction... 3 Safety information... 4 Scope of delivery... 5 Technical data...
More informationDET-RWATER Flood Detector Installation Guide
DET-RWATER Flood Detector Installation Guide Fig 1 1 2 3 4 5 Fig 2 Page 2 2 SUPER DISABLE ALARM ON DRY DISABLE TAMP SENSOR ENABLE VIEW STATE Fig 3 Page 3 1mm Fig 4 Page 4 1. Introduction The DET-RWATER
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit
400 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL External Sounder & Strobe Unit Contents Section Page 1. Installation 3 1.1 Mounting the Unit 3 1.2 Patented Engineer Hold-Off Mode 3 1.3 Installing
More informationNEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.
VI64 Version:1.1 Issued 06/12/2007 INTRODUCTION Ventcroft s external sounder/strobes offer an unsurpassed range of models which provide for virtually any installation need. Most models feature a robust
More informationUser Guide. Contents. About this guide. i-on Style Security System
i-on Style Security System User Guide Contents About this guide.... 1 About i-on Style... 2 System components.... 2 Control unit... 2 Detectors... 2 External sirens... 3 Remote controls... 3 HUA transmitters...
More informationInstallation Manual. Odyssey X Series INS627-2
Installation Manual Odyssey X Series INS627-2 Introduction Odyssey X is a new range of modular external warning devices available in standard or backlit variants. The modular design allows for a choice
More informationContents 1. Introduction Using the Fob... 4
Contents 1. Introduction... 1 Fitting the Battery... 1 A Guided Tour... 2 Operating the buttons... 3 2. Using the Fob... 4 Setting the System... 4 Part Setting the System*... 4 What Happens if the System
More informationSECURIT 700L PLUS ENGINEERING MANUAL
SECURIT 700L PLUS ENGINEERING MANUAL C & K Systems Ltd 13/03/97 C031-096-02 NEW ENHANCED FEATURE SET Securit 700L PLUS Engineering instructions INTRODUCTION The Securit 700L is a microprocessor intruder
More informationNRB100. Installation and Programming Manual INSTALLATION NRB100 AND PROGRAMMING MANUAL
S E L F - P O W E R E D H O R N S T R O B E F O R O U T D O O R U S E INSTALLATION AND PROGRAMMING MANUAL 1 Table of contents Table of contents............................... 2 Chapter 1 Overview...........................
More informationSTERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL
STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL IMPORTANT: Please note the Sterling 10 LCD keypad is not compatible for use with the Sterling 10 ICON keypad. RINS1413-1 Pyronix
More informationALARM SYSTEM USER GUIDE
ALARM SYSTEM USER GUIDE Issue 2 Compliance Statements... iii 1. Introduction... 1 Alarm System... 1 Keypad... 2 Proximity Tags... 2 Mains Power Failures... 4 About this Guide... 4 2. Everyday Operation...
More informationPage ii. Cooper Security Ltd. 2012
MENVIER SECURITY Cooper Security Ltd. 2012 IN NO EVENT WILL COOPER BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INDIRECT LOSS OR DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES, LOSS OF
More informationWarning: Mains voltages are present inside control unit. No user serviceable parts inside.
Eaton s Security Business. 2014 IN NO EVENT WILL EATON S SECURITY BUSINESS BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INDIRECT LOSS OR DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES,
More informationExternal Wireless Sounder
External Wireless Sounder Model: WL RWS401 Installation and Programming Instructions Table of Contents Introduction... 3 Operational Functions... 3 Alarm / Tamper Indication... 3 Low Battery Indication...
More informationInstallation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE
SELF-POWERED S I R E N A A U SOUNDER/FLASHER T O A L I M E N T A T A FOR P E R OUTDOOR E S T E R NUSE O INSTALLATION MANUALE AND DI PROGRAMMING INSTALLAZIONE MANUAL E PROGRAMMAZIONE 1 Table of contents
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationInstallation Manual RINS1211-4
Installation Manual 2x 2x RINS1211- Contents Page System Overview Technical Specification 5 Overview 6 The Control Panel 6 The Printed Circuit Board The Tamper Spring and Connections 8 Connections 9 Transformer
More informationContents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2
TM C P 7 / C P 8 I NSTALLATION I NSTRUCTIONS TM Contents Introduction...................... 2 Mains Safety.................. 2 Good Working Practice.......... 2 Installation....................... 3 Control
More informationM550 and M600. Installation Instructions
M550 and M600 Installation Instructions Cooper Security Limited 2005-2006 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security
More informationInstallation Instructions
Minn-XE Manuel issue no //0 7:9 am Page Installation Instructions Flashguard The Installer s Choice Minn-X Internal Alarm Sounder Minn-XE Internal Alarm Sounder with strobe Minn-XW External Alarm Sounder
More informationGARDTEC 580. Installation Instructions
GARDTEC 5 0 0 S E R I E S GARDTEC 580 Installation Instructions Contents Introduction 1 Planning the Control Panel Location 2 Installation 2 Cable Entries 3 Mains Supply Connection 4 Terminal Block Connections
More informationTS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)
Installation & User Guide Compatible Equipment CPA6 0M - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496527 Issue A 1 of 16 TS5160 Overview Introduction Specification
More informationInstallation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels
CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panel with Communicator Interface Table of Contents Table of Contents Section Page 1 Programming Summary 4 1.1 Programming Menu 4 1.1.1
More informationUSER GUIDE HARDWIRED CONTROL PANELS
USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7
More informationExternal Wireless Sounder
External Wireless Sounder WL S50 Installation and Programming Instructions 2 Wireless Sounder Instructions Table of Contents Introduction... 4 Operational Functions... 4 Alarm / Tamper Indication...4 Low
More informationWIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)
WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3) The wireless window/door contact sensor is used to protect your door/window from intruders when used with the WHA1 Wireless Home Alarm System. Please ensure
More informationi on Compact Security System
i on Compact Security System Administration and User Manual Issue 1 Control unit software version 5.03 Eaton 2017 The information, recommendations, descriptions and safety notations in this document are
More informationSaffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.
Saffire+ 8-12 User & Installation Manual IMPORTANT This manual should be left with the panel after installation. We reserve the right to change product specifications without prior notice. Copyright VRC
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationIntruder alarm system Operating Instructions
Intruder alarm system Operating Instructions 1 2 3 4 5 6 TA PA ZONE Learn Error AccentaG3 mini Servicing organisation details Servicing organisation (Installer) name: Telephone number: Date of installation:
More informationSECURIT 700L USER MANUAL
SECURIT 700L USER MANUAL C & K Systems Ltd 6/12/95 Securit 700L User instructions This manual will give you all the information you need to operate and control the Securit 700L Control Panel. This manual
More informationAP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual
AP10LED 10 Zone onboard LED Alarm Panel SAFETY Engineering Manual Before proceeding with the installation, please note the following safety warnings: DO NOT connect the mains supply directly to the product,
More informationTS400 & TS410. Intruder Alarm Control Panels. Operating Instructions
TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always
More informationINSTALLATION MANUAL PC56O. Version 1.OA
INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone
More informationCONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3
CONTENTS INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3 INSTALLATION 4 Nexus 8 system diagram 4 Nexus 8 internal layout 5 Removing the gear tray 5 Mounting the panel / Cable
More informationHA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE
D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system
More informationMatrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1
Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance
More informationHARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
More informationLong Range Radio Alarm Transmitter
W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. TM
More informationSECURIT 703 USER MANUAL
SECURIT 703 USER MANUAL C & K Systems Ltd THE SECURIT 703. USER INSTRUCTIONS VERSION 1.4 September 1996 C031-111-03 1.0 SETTING 1.1 FULL SET To start the exit procedure ensure all alarmed zones are clear
More informationQUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP
QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP PROGRAMMING STARTS Entering Installer mode If you want to get into program mode press followed by your installer code, default set to 000000
More informationi on Next Generation Security System Engineering Guide
i on Next Generation Security System Engineering Guide Issue 1 Control unit software version 5.0 Eaton s 2016 The information, recommendations, descriptions and safety notations in this document are based
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationKFP-CF Series Operation Manual
KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire
More informationDigiplex System V2.14 / V2.2ACC. Control Panel Programming Guide
Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple
More informationContents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2
TM TM C P 8 L L C D I NSTALLATION I NSTRUCTIONS Contents Introduction...................... 2 Mains Safety.................. 2 Good Working Practice.......... 2 Installation....................... 3 Control
More informationWireless Keypads LKP(E)S8M Series
Wireless Keypads LKP(E)S8M Series User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully.
More informationUSER GUIDE HARDWIRED CONTROL PANELS
USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 4 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...
More informationHARDWIRED CONTROL PANELS
USER'S GUIDE HARDWIRED CONTROL PANELS Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited
More informationProtégé Eclipse LED Keypad User Manual PRT-KLES
Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology
More informationEC-P Zone Intruder Alarm System
EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...
More informationInstallation and user manual for the BiWire / Conventional Repeater Panel
Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....
More informationIntruder - Fire - Water Combined Alarm
65 Intruder - Fire - Water Combined Alarm Installation Manual and User Operating Instructions TALE OF CONTENTS Page First Power-Up 2 Power Supply Unit 3 Input & Detection Circuits 3 Output & Alarm Circuits
More informationDOLKPL1KB DOLKPS1KB DOLKSF1KB
DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL INSTRUCTIONAL VIDEO 1] Connection Terminals 2] Basic Wiring Example 3] Quick Start Guide 4] Programming Guide 5] Specifications 1 Connection Terminals The DOLKPS1KB/DOLKPS1KB/DOLKSF1KB
More informationFMR Installation Instructions. Addressable Fire System Controller
FMR-7033 EN Installation Instructions Addressable Fire System Controller EN 2 FMR-7033 Installation Instructions Contents Contents Contents...2 1.0 Introduction...3 2.0 Description...3 3.0 Device Mounting...3
More informationINSTALLATION MANUAL SECURIT 802 CONTROL PANEL
INSTALLATION MANUAL SECURIT 802 CONTROL PANEL S802 CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power
More informationScantronic Leading the way in security
USER GUIDE (16 ZONE) HARDWIRED CONTROL PANEL Scantronic Leading the way in security Contents 1. Introduction 3 The 9800+ (16 zone) System... 3 The Keypad... 3 About This Guide... 5 2. Everyday Operation
More informationUSER GUIDE HARDWIRED CONTROL PANELS
USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...
More informationINSTALLATION GUIDE. For products. Gardtec 370 & 581
INSTALLATION GUIDE For products Gardtec 370 & 581 Contents INTRODUCTION Introduction..................................3 Tools Required...............................3 Other Equipment Required......................3
More informationScantronic Leading the way in security
USER GUIDE 808 HARDWIRED CONTROL PANEL Scantronic Leading the way in security Contents 1. Introduction... 3 The 808 System... 3 Using the Keypad... 4 About This Guide... 5 2. Everyday Operation... 6 Setting
More informationM800, M800iD Plus, M1000 and M3000. User's Guide
M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security
More informationLong Range Radio Alarm Transmitter
TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3W FEATURES Transmits alarm information to a long range radio network Varitech Transmission Format Note: If automatic SIA is used in
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationGROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual
GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer Users Manual Revision 1.2 20 July 2011 : USERS MANUAL March 2007 Table of Contents FOREWORD.... 3 GUARANTEE.... 4 INTRODUCTION.. 5 OPERATION WITHOUT
More informationMatrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1
Matrix 424 832 832+ Installation Manual Software Version 4 RINS918-1 EN50131-1 Security Grade 2 Environmental Class 2 CONTENTS 1. INSTALLATION & CABLING RULES...1 1.1 Tools Required... 1 1.2 Mains Wiring...
More informationVoice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128
Voice Module Installation Guide For use with ProSYS 16, ProSYS 40, ProSYS 128 Important Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary
More informationLMA LINE MONITOR ALERT USER S MANUAL
LMA LINE MONITOR ALERT USER S MANUAL Janus is a brand of Avire Avire Inc 415 Oser Avenue, Suite Q, Hauppauge, New York 11788 Phone: 631 864 3699 Toll Free: 800 527 9156 Fax: 631 864 2631 Email: sales.us@avire-global.com
More informationINSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup
115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP66 Weight: 5.5 kg single AC unit 7.0 kg four way AC unit Marking: Installation Requirements 1) Introduction The A131 high
More informationAdvantage 6 Alarm Panel
Issued ugust 1997 9778 Instruction Leaflet dvantage 6 larm Panel Introduction The control panel is designed to be simple to install, programme, and to use. The 16 button keypad allows you to select, change,
More informationELECTRONIC SOUNDER STROBE Model : AVD-C407
ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an
More informationInstallation and Operation Guide EXTERNAL SIREN
EXTERNAL SIREN CTENTS 01. INTRODUCTI 03 02. INSTALLATI ATI 04 2.1. Installing the External Siren on the Active SmartHome 04 2.2. Power Supply 07 2.3. Mounting the External Siren 08 03. OPERATI 11 3.1.
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationIFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32
1) DESCRIPTION IFP-2.2 Manual IFP-2.8 and IFP-2.2 is a microprocessor controlled Fire Panel with 2 loops intended either for privat Homes & Apartments or larger installations. The two loops are balanced
More information5000 SERIES 8 ZONE INSTRUCTION MANUAL
5000 SERIES 8 ZONE INSTRUCTION MANUAL NESS SECURITY PRODUCTS 4/167 PROSPECT HIGHWAY SEVEN HILLS. 2147 NSW AUSTRALIA SYDNEY Phone: (02) 8825 9222 (Head Office) BRISBANE Phone: (07) 3343 7744 MELBOURNE Phone:
More information1X-F Series Installation Manual
1X-F Series Installation Manual P/N 501-415003-1-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationM113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version
GROUP OF COMPANIES MERLIN STEALTH M113S Electric Fence Energizer M113S Users Manual Revision 1.0 Date: 29 January 2007 Table of Contents FOREWORD.... 3 GUARANTEE.... 4 INTRODUCTION.. 5 OPERATION WITHOUT
More informationATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet
ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet EN 1 2 1 3 2 4 1 5 12V 6 2 0V D+ D- CON3 7 CON1 ON 3 1 2 3 4 1234 8 3 4 1 0 ON 1 2 3 4 METAL METAL Address 1 1 0 ON 1 2 3 4 Address 2 2011
More information5 Sounds and Indications
5 Sounds and Indications 5.1 Sounder Tones Mode: Tone: 5.2 Indications Exit Soft continuous tone Fault on exit Soft intermittent tone Entry Soft pulsing pips Walk test Soft pulsing pips Keypad entry Soft
More informationKM300 Carbon Monoxide Detection System Installation Manual
GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole
More informationInstallation Manual. Premier IXP-W INS538
Installation Manual Premier IXP-W INS538 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the
More informationUser Manual. Security Systems Security System L208
User Manual Security Systems Security System L208 a Contents This hand book is a technical instruction document for the installation, commissioning and operation of the L208 intrusion alarm security system.
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationD-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit
D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationFR-4000 & FR-8000 Fire Alarm Monitor Installation Manual
FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual Table of Contents Introduction 1 System Components 2 Wiring Block Diagram 3 Connection Diagram for One Sensor 4 Connection Diagram for Multiple
More informationTS700. Intruder Alarm Control Panel. Installation & Programming Instructions OPEN
TS700 Intruder Alarm Control Panel OPEN OPEN Installation & Programming Instructions Contents Overview Introduction......................... 3 Control Panel........................ 3 Remote Keypads and
More informationElmdene Products. Technical Guide for Installation and Service Engineers
Elmdene Products Technical Guide for Installation and Service Engineers Click or uch to Navigate Contents Page Introduction 4 Magnetic Contacts 6 Wire Potted - Key Points 5 Connection - All Models 6 Identifying
More informationAll-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160
All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
More informationTHIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS
THIS GUIDE SUPPORTS MATRI 424 & 832 CONTROL PANELS Software Version V1 08 RINS 295 ISSUE 4 DECEMBER 2001 WARRANTY This product is sold subject to our standard warranty conditions and is warranted against
More informationWD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.
Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction
More informationVAP304 PRO INSTALLATION & OPERATION MANUAL
VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password
More informationPROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX
PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal
More informationDoor/Window Sensor. Set-Up Guide
Door/Window Sensor Set-Up Guide Thanks for choosing Rogers Smart Home Monitoring! Once you ve set-up your Door/Window Sensor, you can receive notifications if a window or door in your home opens unexpectedly.
More informationIntruder alarm system Operating Instructions
Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET S Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details Servicing organisation
More informationFire Control Panel. Installation & Programming Manual TABLE OF CONTENTS
Fire Control Panel Installation & Programming Manual TBLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Inputs 4 Outputs 4 LED Indications 4 User Keypad Functions 5 Engineer Keypad Functions 6
More informationPitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC
PitBoss User Manual Version 1.5 10/24/2013 Copyright 2013 PumpAlarm.com, LLC www.pumpalarm.com 1 CONTENTS Introduction... 4 How Does the PitBoss Work... 4 What Comes With Your PitBoss... 5 Getting to Know
More informationBT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL
BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4
More information2-Port alarmcharge Hub - Manual
Installation Manual 1. What s in the box 2. Fixture preparation 3. Mounting 4. Mechanical 5. Device power Operation Manual 6. Device connectors and connections 7. Alarming remote control 8. Safety 9. Warranty
More informationTS700. Intruder Alarm Control Panel ENT 0 ESC
TS700 Intruder Alarm Control Panel OPEN _ ~ A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Setting the System Ent er your pa sscode XXXX th en lea ve th e pro tect ed a re a. Unsetting the System Go dir e ct ly to
More information