OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO

Size: px
Start display at page:

Download "OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO"

Transcription

1 OPERATING MANUAL LIQUI-SENSE CONTROLLERS MODEL NO MODEL NO AND LIQUI-SENSE DETECTORS MODEL NO MODEL NO Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A (847) (847) (fax) A Edition 03 Tue Sep 26 14:32:

2 EU Declaration of Conformity Name of Apparatus: Liqui-Sense Controller Model Numbers: Description of Apparatus: Fluid Monitor System Barnant Company declares that the above model is in conformity to the following harmonized standards and directives: Applicable Directives 73/23/EEC 93/68/EEC 89/336/EEC 92/31/EEC 93/68/EEC Applicable Specifications EN /A2: 1995 EN /A1: 1998 Manufacturer s Report Number TR9516 TR9519 The last two digits of the year in which the current configuration of the above models was assessed per the Low Voltage Directive is: 00. Manufacturer: Barnant Company Division Cole-Parmer Instrument Company 28W092 Commercial Avenue Barrington, IL USA Tel.: Manufacturer s Signature: James W. Doll Vice President, Engineering 22 August, 2000 Date WARNINGS: WARNING: CAUTION: SAFETY PRECAUTIONS If the equipment is used in a manner other than as specified, protection provided by the equipment may be impaired. No user serviceable parts are inside of this Controller. Refer servicing to your dealer. The LIQUI-SENSE Controller must be positioned so leaking liquid will not enter the rear power connectors. Use of a power line with a Ground Fault Interrupt (GFI) is recommended. Use with caustic liquids not compatible with detector materials voids warranty. i Tue Sep 26 14:32:

3 TABLE OF CONTENTS Title Page SAFETY PRECAUTIONS i INTRODUCTION APPLICATIONS DESCRIPTION... 6 INSTALLATION AND SETUP OPERATION Operator Control and Indicators Startup Procedure Operational Checks SENSITIVITY ADJUSTMENT MAINTENANCE AND TROUBLESHOOTING Fuse Replacement Cleaning Troubleshooting ACCESSORIES SPECIFICATIONS WARRANTY PRODUCT RETURN TECHNICAL ASSISTANCE APPENDIX A: AUXILIARY CABLE CONNECTIONS Only the Model LIQUI-SENSE Controller is UL and cul listed. Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries. 1 Tue Sep 26 14:32:

4 INTRODUCTION The LIQUI-SENSE Controller is a two-channel alarm system used to sense liquid leaks using a specially designed detector or used with other liquid detectors such as high or low liquid level detectors. The Model LIQUI-SENSE Controller operates from 115V AC and the Model operates from 230V AC. When an alarm condition is sensed on either channel, the LIQUI-SENSE Controller can perform the following actions: Disconnect power to a pump drive. Activate an auxiliary pump drive to resume pumping through a second pump drive. Activate the front panel red ALARM ON indicator. Sound an audible alarm if the audible alarm is enabled. Provide a contact closure output that can be used to activate an Environment Monitor for automatically telephoning the user of the failure, or to activate any other device that operates from a contact closure input. The contact closure may also be used to operate shut-off or switchable valves to redirect flow. The LIQUI-SENSE Detector Model (detector with cable) or Model (detector without cable) is used to sense leaks in pump heads resulting from ruptures of the tubing. This detector is not supplied with the unit and must be ordered separately. (See ACCESSORIES.) 2 Tue Sep 26 14:32:

5 APPLICATIONS The LIQUI-SENSE Controller and LIQUI-SENSE Detector can be used with a wide variety of different pump systems for leak detection. The alarm controller has two inputs. These can both be used with LIQUI-SENSE Detectors, or one input can be used with a LIQUI-SENSE Detector and the second input used with other type detectors such as a liquid level detector for determining high or low levels in a container. Figures 1 through 5 show various suggested detector arrangements in different pump systems. Tubing is omitted for clarity. Figure 1. Typical B/T RAPID-LOAD Pump with LIQUI-SENSE Detector positioned under open side of pump 3 Tue Sep 26 14:32:

6 Figure 2. Typical L/S Cartridge Pump with two LIQUI-SENSE Detectors centered under the group of cartridges Figure 3. Typical L/S EASY-LOAD Pump with LIQUI-SENSE Detector positioned under main pump, auxiliary pump mounted on top of main pump and both pumps connected to Alarm Controller for automatic switch over when a leak is detected 4 Tue Sep 26 14:32:

7 Figure 4. Typical I/P EASY-LOAD Pump with LIQUI-SENSE Detector centered under the pump and a level detector connected to the second input of the Alarm Controller Figure 5. Standard Stacked Pump System with two LIQUI-SENSE Detectors positioned for optimum leak detection 5 Tue Sep 26 14:32:

8 DESCRIPTION The LIQUI-SENSE Controller, shown in Figure 6, is used to monitor various liquid detector devices. When an alarm condition is detected, the controller deactivates the rear panel MAIN OUTPUT power connector and supplies power to the AUXILIARY OUTPUT power connector. Also, when the alarm condition is detected, a contact closure output is provided at the rear panel CONTACT CLOSURE OUTPUT connector (a 1/8-inch phone-type connector) for activating remote devices such as an Environment Monitor or a second pump drive. The fault condition is indicated by a red ALARM ON indicator on the front panel and by an audible alarm (unless the ALARM AUDIBLE switch has been set to OFF). Figure 6. LIQUI-SENSE Controller (Alarm Module) The MAIN and AUXILIARY connectors, shown in Figures 7 and 8, are used to connect to external devices such as pumps. The pump connected to the MAIN OUTPUT connector will operate when no alarm condition exists. When an alarm condition is detected, power to the MAIN OUTPUT connector is turned off and power is applied to the AUXILIARY OUTPUT connector. Thus, if no pump is connected to the AUXILIARY OUTPUT connector, pumping will cease. If a pump is connected to the AUXILIARY OUTPUT connector, that pump will be turned on. The switch over occurs within one second after detection of an alarm condition. 6 Tue Sep 26 14:32:

9 Figure 7. Rear Panel Model (115V AC) Figure 8. Rear Panel Model (230V AC) Power is applied to the unit through a permanently attached line cord on the 115V AC model and through an IEC 320/CEE 22 connector coupler (female line cord/male socket) on the 230V AC units. A number of accessory input and output power cords are available. (See ACCESSORIES.) The power is controlled by the rear panel OFF-ON switch. Power-on is indicated by a front panel green POWER ON indicator. The CONTACT CLOSURE OUTPUT connector (rear panel) provides a latched contact closure output, rated 30V DC at 1 ampere max., when an alarm condition is detected. This output can be connected to an Environment Monitor, which then can telephone the user to signal the alarm condition. This output can also be connected to any device that operates from a contact closure condition, such as a warning system. An accessory cable is listed in the ACCESSORIES Section. 7 Tue Sep 26 14:33:

10 The locking modular INPUT connectors (front panel) connect to external detectors. Each input has a SENSITIVITY adjustment that is used only with the LIQUI-SENSE Detectors. The sensitivity is factory set so that when the detector is placed within one inch of the pump, less than one ml of water-based liquid will trigger the detector. For other types of liquids, or to change the sensitivity level, refer to the SENSITIVITY ADJUSTMENT Section. Sensitivity adjustment may be required when operating with cables longer than 3-1/2 feet or in a high-temperature, high-humidity environment. The LIQUI-SENSE Controller is housed in a slate gray ABS plastic enclosure, with aluminum front and rear panels. The unit can be placed on a flat surface, on a support platform or on the top surface of some MASTERFLEX or other type pumps. The LIQUI-SENSE Detector Model (with cable) or Model (without cable), Figure 9, operates on a capacitance change principle. The detector is designed to be placed under the pump.if a leak occurs in the pump tubing, the liquid will fall on the top surface of the detector. When sufficient surface area is moistened (less than 1 ml of water-based liquid when using the factory sensitivity setting), the change in capacitance is sufficient to activate the alarm circuits. The detector has a locking modular type connector. The cable between the detector and the controller is 3-1/2 feet long with modular locking connectors on both ends. Ten-foot and fifteen-foot accessory cables are available. Refer to APPENDIX A for pin configuration for the cables when connecting other detector types. Figure 9. LIQUI-SENSE Detector Model A four-inch hook-and-loop fabric fastener strip allows for attachment of the detector pad to a flat surface to prevent the detector pad from moving. The detector pad can also be permanently mounted by attaching it to a flat surface with two #4 screws. The screw locations at the corners of the detector pad are indicated by two circular markers. The detector structure will need to be punctured by the screw for permanent attachment. 8 Tue Sep 26 14:33:

11 INSTALLATION AND SETUP NOTE: Retain all packing materials until proper operation has been verified. WARNING: The LIQUI-SENSE Controller must be positioned so leaking liquid will not enter the rear power connectors. Use of a power line with a Ground Fault Interrupt (GFI) is recommended. Proceed as follows to setup the LIQUI-SENSE Controller: 1. Place the rear panel power OFF-ON switch in the OFF position. NOTE: For 115V AC pump models, the pump power cord will plug directly into the MAIN OUTPUT or AUXILIARY OUTPUT connectors on the rear panel of the LIQUI-SENSE Controller. For 230V AC models, use pump cable for pumps with European connectors or pump cable for pumps with other style connectors. 2. Connect pumps as follows: a. If a main pump and a standby (auxiliary) pump are to be used, connect the main pump to the MAIN OUTPUT connector on the rear panel and connect the standby (auxiliary pump) to the AUXILIARY OUTPUT connector. b. If only the main pump is to be used with no standby, and the pump is to shut down when an alarm condition exists, connect the main pump to the MAIN OUTPUT connector. The AUXILIARY OUTPUT connector can be used to power other devices such as lights, remote alarms or other equipment. c. If only the main pump is to be used with no standby, and the pump is not to shut down when an alarm condition exists, connect the main pump to a separate power source. The MAIN OUTPUT connector and the AUXILIARY OUTPUT connector can be used to power other devices such as lights, remote alarms or other equipment. 3. Connect one end of the detector cable(s) to the front panel INPUT connector(s) and the other end to the desired detector(s). Only one detector can be connected to each INPUT connector. Detectors must be connected using a cable configured as shown in APPENDIX A. Make sure cable connections are secure or unit will not function properly. 4. The LIQUI-SENSE Detector must be positioned under the pump so that any leakage will drip onto the detector pad target area (area outlined with the black lines). The detector can be secured in place using hook-and-loop fabric fasteners or can be permanently fastened with #4 screws. Two circular marks are located on the outer edge of the detector 9 Tue Sep 26 14:33:

12 for position of screws. Do not insert screws in any other location on the detector pads. The location of the detector for various typical pumps are as follows: a. For a typical B/T RAPID-FLOW pump, the detector should be located directly under the opening at the right side of the pump as shown in Figure 10. Figure 10. Positioning a LIQUI-SENSE Detector under a B/T RAPID-FLOW Pump b. For typical L/S Cartridge pumps, the detector should be centered under the group of cartridges. For large numbers of cartridges, use two detectors as shown in Figure 11. Figure 11. Positioning LIQUI-SENSE Detectors under an L/S Cartridge Pump 10 Tue Sep 26 14:33:

13 c. For typical L/S EASY-LOAD pumps, the detector should be centered directly under the weep hole as shown in Figure 12. Figure 12. Positioning a LIQUI-SENSE Detector under an L/S EASY-LOAD Pump d. For typical I/P EASY-LOAD pumps, two weep holes are located under the pump. A single detector can be centered under the weep holes as shown in Figure 13. For better reliability, two separate detectors can be used with one centered under each weep hole as shown in Figure 14. Figure 13. Positioning a single LIQUI-SENSE Detector under an I/P EASY-LOAD Pump 11 Tue Sep 26 14:33:

14 Figure 14. Positioning two LIQUI-SENSE Detectors under an I/P EASY-LOAD Pump e. For typical standard stacked pumps where only one or two pumps are used, a single detector can be centered under the stack of pumps. When a larger number of pumps are used, two detectors should be positioned to assure optimum leak detection as shown in Figure 15. Figure 15. Positioning two LIQUI-SENSE Detectors under a stack of Standard Pumps 12 Tue Sep 26 14:33:

15 5. If an Environment Monitor (such as a COLE-PARMER Model 08330) is to be used or if another external device requiring a contact closure to activate it is to be used, connect the 1/8-inch phone cable connector from the rear panel CONTACT CLOSURE OUTPUT connector to the external device. 6. Connect the LIQUI-SENSE Controller POWER INPUT cord as follows: a. For 115V AC unit, connect line cord to 115V AC 50/60 Hz power source. b. For 230V AC unit, connect power cable between rear panel POWER INPUT connector and 230V AC 50/60 Hz power source. This completes the electrical connectors. Proceed with the OPERATION Section. OPERATION Operator Controls and Indicators All operator controls except the power OFF-ON switch are located on the front panel as shown in Figure 16. These controls and indicators are as follows: POWER ON Indicator Green LED illuminates when power OFF-ON switch is in the ON position and input power is present. SENSITIVITY Controls Adjusts the sensitivity of the circuit for use with the LIQUI-SENSE Detectors. (Pre-set at factory for typical applications.) ALARM TEST Momentary push-button. Tests the audible alarm, the visual alarm, the switching of AC power from the rear panel MAIN OUTPUT to the AUXILIARY OUTPUT connectors and the contact closure at the rear panel CONTACT CLOSURE OUTPUT connector. These are activated while the button is pushed and reset automatically upon release. ALARM ON Indicator Red LED illuminates when an alarm condition is present. 13 Tue Sep 26 14:33:

16 ALARM RESET ALARM AUDIBLE OFF-ON Switch Power OFF-ON Momentary push-button. Resets alarm circuits after alarm condition is removed (detector pad wiped clean, tank filled, etc.). While push-button is held in, the system reverts to the non-alarm condition. If the alarm condition is not cleared when the ALARM RESET switch is released, the unit will go back into the alarm condition. It may be convenient to hold in the ALARM RESET button while priming or purging the system when a level detector is used. In the OFF position, the audible alarm will not sound during an alarm condition. In the ON position, the audible alarm will sound during an alarm condition. Rocker type switch located on rear panel. Disconnects all AC power from unit and from equipment connected to the MAIN OUTPUT or AUXILIARY OUTPUT connectors. Figure 16. LIQUI-SENSE Controller Front Panel 14 Tue Sep 26 14:33:

17 Startup Procedure 1. Check that all connections have been made as described in the INSTALLATION Section. 2. Check that detectors are connected and properly positioned. Only one detector can be connected to each channel. Use hook-and-loop fabric fasteners to secure detector in position or, if permanent mounting is desired, detector can be attached with #4 screws as described in the INSTALLATION Section. NOTE: Tubing may break at locations other than expected. Using a second detector can provide for better detection. 3. If the audible alarm is to operate, set ALARM AUDIBLE switch to the ON position. If no audible alarm is desired, place ALARM AUDIBLE switch in the OFF position. 4. Set rear panel power OFF-ON switch to the ON position and check that the front panel green POWER ON indicator is lit. The equipment should now be operating normally. 5. If an alarm condition exists, proceed to the SENSITIVITY ADJUSTMENT Section. If level detectors are used, they may need to be inverted or rotated 180 for proper operation. The audible alarm can be turned off by placing the ALARM AUDIBLE switch in the OFF position. 6. Perform the LIQUI-SENSE Detector Sensitivity Check using drops of the same liquid used in your application. Operational Checks LIQUI-SENSE CONTROLLER An operational check of the LIQUI-SENSE Controller can be performed using the ALARM TEST switch. This test should be performed only when temporary transfer of power from the MAIN OUTPUT connector to the AUXILIARY OUTPUT connector will not be disruptive. Proceed as follows: 1. Set the ALARM AUDIBLE switch to ON for the audible alarm to be activated or to OFF to deactivate the audible alarm. 2. Set power OFF-ON switch to ON position and check that POWER ON indicator is illuminated. 3. Press and hold the ALARM TEST SWITCH. Check that the audible alarm sounds (if activated), the ALARM ON indicator is illuminated, that power shifts from the MAIN OUTPUT connector to the AUXILIARY OUTPUT connector and that the CONTACT CLOSURE OUTPUT activates any equipment connected to the output. 15 Tue Sep 26 14:33:

18 LIQUI-SENSE DETECTOR SENSITIVITY CHECK The LIQUI-SENSE Detector sensitivity may be checked as follows: 1. Connect detector to one of the front panel INPUT connectors, if not already connected. 2. Place water one drop at a time on the detector pad. Do not drop water from more than one inch. 3. Check number of drops required to activate alarm. Pre-set factory setting should activate alarm with less than 1 ml of liquid. If activation level is not as desired, refer to SENSITIVITY ADJUSTMENT Section. 4. After activating alarm, momentarily press then release the RESET button. Alarm condition should still be present. 5. Wipe detector surface clean with a dry cloth and momentarily press, then release, the RESET button. Alarm condition should terminate, ALARM ON indicator should extinguish and, if activated, audible alarm should turn off. SENSITIVITY ADJUSTMENT Generally, no sensitivity adjustment of the LIQUI-SENSE Controller is required. However, various liquids or environmental conditions such as temperature and humidity may require adjustment of the SENSITIVITY controls for use with the LIQUI-SENSE Detectors. The SENSITIVITY adjustment is accessed through the small hole adjacent to each INPUT connector. Contact closure or logic level detectors do not require adjustment of the SENSITIVITY control. If the factory default setting for sensitivity is not activating the alarm, or is falsely activating the alarm for the liquid being sensed, adjust the input sensitivity with one channel connected at a time. Turn the SENSITIVITY control clockwise to increase sensitivity (fewer drops will activate) or counterclockwise to decrease sensitivity. NOTE: If the sensitivity is increased so much that the red ALARM ON indicator illuminates, the RESET button must be depressed each time sensitivity is decreased until the indicator extinguishes. Normal sensitivity adjustment is between one-quarter and two turns counterclockwise from the activation point. The activation point is defined as that sensitivity set when ALARM ON indicator just illuminates. Refer to Table 1 for typical sensitivity settings for various liquids. The middle column indicates the number of turns counterclockwise from the activation point that the 16 Tue Sep 26 14:33:

19 sensitivity control should be set for proper operation. The last column indicates the quantity of fluid required in the target area of the detector to activate the detector. Sensitivity will change with detector position or when used near metallic objects (e.g., table). Also, sensitivity changes when using longer (optional) cables. CAUTION: Use with caustic liquids not compatible with detector materials voids warranty. Table 1. Typical Sensitivity Settings Fluid Type Setting (Turns ccw from activation point) Nominal Volume Distilled Water <1mL Tap Water <1mL Acetic Acid (10% max.) <0.5mL Alcohols <0.5mL Glycerin <2.0mL 10W Motor Oil 1 2 <2.0mL WARNING: MAINTENANCE AND TROUBLESHOOTING No user serviceable parts are inside of this Controller. Refer servicing to your dealer. Fuse Replacement The 115V AC LIQUI-SENSE Controller uses a 10-A Slo-Blo fuse (3AG, part number B ), which is located in the fuse holder on the rear panel. The 230V AC LIQUI-SENSE Controller uses a 6.3-A fuse (5 x 20 mm, part number B ), which is located in the drawer in the POWER INPUT connector on the rear panel. Replace only with the correct fuse. Cleaning Clean the top surface of the detector pad with a soft, dry cloth. If liquid cleaner is used, rinse and dry thoroughly before resuming operation. Keep the LIQUI-SENSE Controller enclosure clean by using a mild detergent. Never immerse or use excess fluid. 17 Tue Sep 26 14:33:

20 Troubleshooting The following chart will help identify most problems that can be corrected by the operator. If the fault cannot be located, return unit for servicing. Troubleshooting Chart SYMPTOM CAUSE REMEDY POWER ON indicator does not illuminate with Power OFF-ON switch in ON position ALARM LIGHT illuminates but audible alarm does not sound Alarm does not activate for a fault condition RESET button does not reset unit when depressed Alarm activated but pump continues to operate Alarm activated but auxiliary pump does not turn on Fuse blown Power cord not plugged into active power source ALARM AUDIBLE switch not set to ON position Detector not connected Sensitivity set too low Detector cable defective Detector inoperative Fault not cleared Sensitivity set too high RESET button failure Pump not connected to MAIN OUTPUT but directly to a power source Auxiliary Pump not connected to AUXILIARY OUTPUT Replace fuse Plug in power cord Set switch to ON position Connect detector Increase sensitivity (LIQUI-SENSE Detector only) Replace cable Replace detector Clear fault Lower sensitivity (LIQUI-SENSE Detector only) Return unit for servicing Connect pump to MAIN OUTPUT for shutdown when an alarm condition is sensed. Connect auxiliary pump to AUXILIARY OUTPUT 18 Tue Sep 26 14:33:

21 ACCESSORIES The accessories and service parts listed below are available from your dealer. Part Name Part Number LIQUI-SENSE Detector Pad and 3.5 ft Cable LIQUI-SENSE Detector Pad Cable, Detector Pad, 3.5 ft Cable, Detector Pad, 10 ft Cable, Detector Pad, 15 ft IEC320M/IEC320F Pump power cable (connects modular plug to LIQUI-SENSE Controller) IEC320F/F Pump power cable (connects European plug to LIQUI-SENSE Controller) Cable with 1/8-inch phone plug Out-of-Liquid Detector Power Cords for 230V AC Controllers European (standard) British Swiss Italian NEMA Type 6-15P Fuse 115V: 10A, 250V, SLO-BLO, 3AG B V: T6.3A, 250V, 5 20mm B Tue Sep 26 14:33:

22 SPECIFICATIONS Output: Contact Closure Output Rating: 30V DC 1 Ampere Maximum Audible Alarm Sound Level: 90 dba Input: Line Voltage Limits (115V AC Controller): V AC 50/60 Hz Single Phase* (230V AC Controller): V AC 50/60 Hz Single Phase Power Dissipation: 1.2 kva maximum AC Line Current: 10 A max at 115V AC 6.3 A max at 230V AC Installation Category: Installation Category II per IEC 664 (Local level appliances, portable equipment, etc.) Construction: Controller Dimensions: 3 in H 8.1 in W 6.3 in D LIQUI-SENSE Detector Dimensions: 5.0 in 2.6 in Weight: 3 lbs Detector Cable Length: 3.5 feet (others available) Enclosure Rating: IP22 per IEC 529 Environment: Operating Temperature Range: 0 C (32 F) to 40 C (104 F) Storage Temperature: 45 C ( 49 F) to 65 C (149 F) Humidity (non-condensing): 10 to 85% Barometric Pressure: 75 to 106 kpa Altitude: less than 2000 m Pollution Degree: Pollution Degree 2 per IEC 664 (Indoor Usage lab, office) Chemical Resistance: LIQUI-SENSE Controller: LIQUI-SENSE Detector: All materials withstand common cleaning solvents. Construction materials used are polyester labels, ABS plastic enclosure and zinc-plated screws. Top layer Flat polyester attached with polyester laminate. Bottom layer Polyester attached with polyester laminate. Connector is ABS plastic. Compliance: 115V: UL508, CSA C22.2, No. 14-M91 230V (For CE Mark): EN /A2: 1995 (EU Low Voltage Directive) and EN /A1: 1998 (EU EMC Directive) * Unit operating voltage range as tested by Underwriters Laboratories. This unit has been designed and tested by the manufacturer for an extended operating voltage range of V AC. 20 Tue Sep 26 14:33:

23 WARRANTY The Manufacturer warrants this product to be free from significant deviations from published specifications. If repair or adjustment is necessary within the warranty period, the problem will be corrected at no charge if it is not due to misuse or abuse on your part, as determined by the Manufacturer. Repair costs outside the warranty period, or those resulting from product misuse or abuse, may be invoiced to you. The warranty period for this product is noted on the Warranty Card. PRODUCT RETURN To limit charges and delays, contact the seller or Manufacturer for authorization and shipping instructions before returning the product, either within or outside of the warranty period. When returning the product, please state the reason for the return. For your protection, pack the product carefully and insure it against possible damage or loss. Any damages resulting from improper packaging are your responsibility. TECHNICAL ASSISTANCE If you have any questions about the use of this product, contact the Manufacturer or authorized seller. We reserve the right to make improvements in design, construction and appearance of our products without notice. 21 Tue Sep 26 14:33:

24 APPENDIX A AUXILIARY CABLE CONNECTIONS Each Cable Assembly is 3-1/2 feet long and is composed of a 6-conductor shielded flat cable with PVC jacket. Ten-foot and fifteen-foot cables are also available. Six pin modular plugs are attached at each end. Refer to the following chart for pin output: Pin Signal Color 1 Ground Black 2 Contact Closure or Logic Low White Input 3 12V DC Red 4 Capacitive Plate Input Green 5 Capacitive Plate Input Brown 6 Shield Guard Bare Tin For level detector (sensors) connections, cut off one end of the six conductor flat cable, or cut the cable in half, if using longer cables, to make two pieces. Strip the shield (metal) and plastic jacket back two inches. Spread the wires. Strip back one inch of the black wire, pin 1, and white wire, pin 2. Fold the other wires back along the plastic jacket and tape or cut off as desired. Twist one lead of the level detector to the black lead of the cable, pin 1, and twist the other lead of the level detector to the white lead of the cable, pin 2. Solder the two connections together or use a wire nut if possible. Tape around exposed bare wire areas. Figure A-1. Level Sensor Connections 22 Printed in U.S.A Tue Sep 26 14:33:

TEMPERATURE CONTROLLER (STANDARD MODEL)

TEMPERATURE CONTROLLER (STANDARD MODEL) OPERATING MANUAL TEMPERATURE CONTROLLER (STANDARD MODEL) 689-0000 689-0005 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739

More information

Aluminum Heating Mantles

Aluminum Heating Mantles Aluminum Heating Mantles ON/OFF HOT User Guide Version 1.3 ON/OFF IEC power inlet socket Power supply switch (large-volume models). Power to either the lower part of the element or the upper and lower

More information

Analog Melting Point Apparatus

Analog Melting Point Apparatus Analog Melting Point Apparatus User Guide Version 1.2 7. Turn off to begin cooling. A brass plug can be used if more rapid cooling is required. IEC power inlet socket (at rear) Magnifying lens Capillary

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

TTT Digital Incubator

TTT Digital Incubator TTT Digital Incubator 135000 135000-2 Operating Instructions N2400342 Rev. 1 08/13 Table of Contents 1.0 Safety... 3 2.0 Intended Use of Product... 4 3.0 Installation... 4 3.1 Unpacking the Unit... 4 3.2

More information

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations! Operator s Manual The Bullet Blender 50 BB50-AU, BB50-DX Congratulations! Congratulations on your purchase of a Bullet Blender 50 by Next Advance, Inc., for mixing, lysing, disrupting, and homogenizing

More information

StableTemp Hotplates, Stirrers and Stirring Hotplates

StableTemp Hotplates, Stirrers and Stirring Hotplates StableTemp Hotplates, Stirrers and Stirring Hotplates OPERATION MANUAL AND PARTS LIST Hotplates: Catalog # Size Voltage Top Plate Material 03405-00 4x4 120 Ceramic 03405-05 4x4 240 Ceramic 03405-10 7x7

More information

TEMPERATURE CONTROLLER R/S (ADVANCED MODEL)

TEMPERATURE CONTROLLER R/S (ADVANCED MODEL) OPERATING MANUAL TEMPERATURE CONTROLLER R/S (ADVANCED MODEL) 689-0010 689-0015 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739

More information

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741

More information

Code 542 Peltier Rack User's Guide

Code 542 Peltier Rack User's Guide Code 542 Peltier Rack User's Guide LT2544/ 1999 Gilson, Inc. All rights reserved June 1999 Table of Contents page Introduction...1-1 Unpacking...1-2 Customer Service...1-3 Technical Specifications...1-4

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet. StableTemp Low Temperature Incubator Model 146E Catalog Number 39063-00(115VAC) 39063-05(230VAC StableTemp Low Temperature Incubator offers laboratories precise temperature control over the -10 C to 60

More information

Wine Cellar. Instruction Booklet. Model: WC-2038

Wine Cellar. Instruction Booklet. Model: WC-2038 Wine Cellar Instruction Booklet Model: WC-2038 IMPORTANT SAFEGUARDS Before the appliance is used, it must be properly positioned and installed as per the instruction in the Installation section. To reduce

More information

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents - English... 1 Instruction Manual Analog, Dry Block Heater, 1 Block, HB1AL Analog, Dry Block Heater, 2 Block, HB2AL Analog, Dry Block Heater, 4 Block, HB4AL Analog, Dry Block Heater, 6 Block, HB6AL Digital,

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

USER MANUAL WATER DISPENSER WITH ICE MAKER

USER MANUAL WATER DISPENSER WITH ICE MAKER USER MANUAL WATER DISPENSER WITH ICE MAKER Model:048-GM-48200 Please read this owner s manual carefully before operating the unit. TABLE OF CONTENTS INTRODUCTIONS... 3 IMPORTANT SAFETY INSTRUCTIONS.. 3

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

3 963/963E Benchtop Air Ionizer Instructions

3 963/963E Benchtop Air Ionizer Instructions 3 963/963E Benchtop Air Ionizer Instructions Index Section Page Safety Information...4 1. Description...5 2. Performance...5 3. Power Requirements...5 4. Installation...5 5. Operation...6 6. Maintenance...6

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94 OPERATION MANUAL StableTemp Economy Mechanical Convection Oven Model : 52412-89,-90,-91,-92,-93,-94 This operation manual describes the important subjects on maintaining the product s functions, safety,

More information

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV Instruction Manual Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV2 9296050000 About This Manual This manual is designed to assist you in optimal usage of your

More information

Operator s Manual. The Quietek

Operator s Manual. The Quietek Operator s Manual The Quietek Congratulations! Congratulations on your purchase of the Quietek euthanization system. Please read this operator s manual which explains proper operation of the instrument.

More information

Thermo-Sealer. Manual Heat Sealer. User Manual

Thermo-Sealer. Manual Heat Sealer. User Manual Thermo-Sealer Manual Heat Sealer User Manual Thermo-Sealer Contents Page Page Introduction 2 Safety 2 Declaration of conformity 3 Caution and safety signs in accordance with IEC 417 4 Unpacking 4 Technical

More information

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual Guardian CR2000 Overhead Ionizing Air Blower User s Manual Tabel of Contents SECTION 1: Description SECTION 2: Safety SECTION 3: Features SECTION 4: Specifications SECTION 5: Installation SECTION 6: Operation

More information

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual Automatic Humidity Controller Model 512 (Revision C) Operating Manual 6/5/03 1 TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 GENERAL DESCRIPTION 3 3 2.1 Humidity Sensor 3 2.2 Control Unit 4 2.3 System Operation

More information

MD-MINI Dry Bath. Instruction Manual

MD-MINI Dry Bath. Instruction Manual MD-MINI Dry Bath Instruction Manual Catalog No. MD-MINI www.majorsci.com service@majorsci.com Version 01B Revision on: 2013.07.15 Packing list MD-MINI: 1x MD-MINI Dry Bath 1x MD-MINI Lid 1x Power Cord

More information

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF INSTRUCTIONS FOR OPERATION AND CARE OF LITTLE Splint Compact Splint Pan Model LS-1 Whitehall Manufacturing is a Member of Acorn Engineering s Family of Companies. 6900-191-001 July 2010 Introduction...3

More information

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE Models: UVS- 1200T, 1900T, 1202T, 1902T Models: UVE- 1200T, 1900T, 1202T, 1902T Table of Contents: Page 2- Shipping and Packing List, Safety

More information

Operating Instructions. Transair Alternating Pressure Care Overlay System

Operating Instructions. Transair Alternating Pressure Care Overlay System Operating Instructions Transair Alternating Pressure Care Overlay System Version 2 March 2013 Transair - Alternating Pressure Care Overlay System Position the Pump Unit on the end of the bed. Connect the

More information

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

ELECTRONIC FLAME SUPERVISION MULTI-BURNER MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,

More information

Barnant Company MODEL NO

Barnant Company MODEL NO Barnant Company DualLogR THERMOCOUPLE THERMOMETER MODEL NO. 600-1050 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739 www.barnant.com

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

RK-02 Multi Point Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual 65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

RK Hydrogen Sulfide Transmitter Operator s Manual

RK Hydrogen Sulfide Transmitter Operator s Manual 65-2331RK Hydrogen Sulfide Transmitter Operator s Manual Part Number: 71-0176RK Revision: B Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at PHASE ROTATION METER 6608 L1/A L2/B 690V 600V CAT III 300V CAT IV L1L2L3 L3/C L R PHASE ROTATION MODEL 6608 User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431

More information

RK-05 Carbon Monoxide Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual 65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

Model 405 AIRGARD Fume Hood Monitor

Model 405 AIRGARD Fume Hood Monitor INSTALLATION AND MAINTENANCE INSTRUCTIONS Model 405 AIRGARD Fume Hood Monitor A TSI Company Model 405 AIRGARD Fume Hood Monitor Specifications Instrument Dimensions Instrument Weight Shipping Weight Green

More information

Installation & Operating Guide

Installation & Operating Guide HOT WATER DISPENSER Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482

More information

Unstirred Baths FLD Series. Unstirred DuoBaths. Note:

Unstirred Baths FLD Series. Unstirred DuoBaths. Note: Unstirred Baths FLD Series Unstirred DuoBaths Note: Always maintain adequate water/oil levels in Foodbath. Periodically check there is sufficient water/oil in the bath at all times. Contents About this

More information

AUC Cell Washer. User Manual

AUC Cell Washer. User Manual AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed

More information

DEMA 830 Laundry Master TM Installation Instructions

DEMA 830 Laundry Master TM Installation Instructions I-656 Pg. 1 of 9 SYSTEM OVERVIEW The DEMA 830 Laundry Master is designed for long reliable use with simplicity in mind for both the installer and user. The system is based on the reliable DEMA peristaltic

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual This manual covers operation of the tcm100 and tcm101 Series Temperature Control Modules.

More information

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08 GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,

More information

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES PHYSITEMP INSTRUMENTS INC 154 Huron Avenue Clifton NJ 07013 USA Tel: 973-779-5577 Fax: 973-779-5954 OPERATING MANUAL BFS-MP SERIES FREEZING STAGES Models BFS-3MP, BFS-5MP, BFS-30MP EB FRONTIS EB BFS-MP

More information

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N 5050-0540 TITLE PAGE General Information...3 Introduction...3 Specifications...3 Physical Parameters...3 Parts Identification...4

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

Premier Hazard STC Instructions

Premier Hazard STC Instructions PREMIER HAZARD Ltd Bessingby Industrial Estate Bridlington YO16 4SJ Tel: +44 (0) 113 239 1111 Fax: +44 (0) 113 239 1131 www.premierhazard.co.uk info@premierhazard.co.uk Premier Hazard STC Instructions

More information

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482

More information

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual 65-2502RK/65-2510RK Oxygen Detector Operator s Manual Part Number: 71-0074RK Revision: A Released: 3/1/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Instruction Manual ET0002 / Version 1.0. Heating Tape

Instruction Manual ET0002 / Version 1.0. Heating Tape Instruction Manual ET0002 / Version 1.0 Heating Tape Contents Introduction 3 General Description 3 Important Safety Advice 4 Electrical Requirements 4 Before Use 5 Prepare Surface 5 Visual Inspection and

More information

Operating Instructions

Operating Instructions Round Tissue Bath VWR Catalog Number 80086-982 VWR Catalog Number 80086-984 Operating Instructions N2400238 Rev. 0 CONTENTS Page 1. Safety... 2 2. Product Information... 3 3. Assembly... 3 3.1 Unpacking...

More information

GUARDIAN : AUTOGUARD. User Manual

GUARDIAN : AUTOGUARD. User Manual 2018 : AUTOGUARD User Manual User Manual - Page 2 : AUTOGUARD Wireless PIR Intrusion Detection System User Manual 2 Contents User Manual - Page 3 Description Page No. 1. System Description 3 1.1 Scope

More information

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001 POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE INSTRUCTIONS Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES MODELS MULTIDECK CLD25 Cold MODEL CLD25 Cold IMPORTANT READ BEFORE USING DISPLAY CASE www.frijado.com Part-number

More information

Digital Heat Block User Manual

Digital Heat Block User Manual Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in

More information

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times USER MANUAL MODELS: COX 115V-N COX 220V-N COX 115V-R COX 220V-R 2364 Leicester Road, P.O. Box 175, Leicester, NY 14481 Phone (585)

More information

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer INSTRUCTION MANUAL Instruction Manual High Throughput Homogenizer Table of Contents Package Contents.............. 1 Warranty.............. 1 Introduction.............. 2 Installation.............. 2 Maintenance

More information

PAC1500Xi PORTABLE APPLIANCE CHECKER

PAC1500Xi PORTABLE APPLIANCE CHECKER PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

RK Multi Point Detector Operator s Manual

RK Multi Point Detector Operator s Manual 65-2480RK Multi Point Detector Operator s Manual Part Number: 71-0198RK Revision: C Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

STEAM LITE S3251UKJR OWNER S GUIDE

STEAM LITE S3251UKJR OWNER S GUIDE STEAM LITE S3251UKJR OWNER S GUIDE IMPORTANT SAFETY INSTRUCTIONS For Household Use Only WHEN USING YOUR SHARK STEAM MOP, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: WARNING:

More information

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B ITEM #0103339 Master Forge & M Design is a registered trademark of LF, LLC. All rights reserved. IMPORTANT READ THIS USER'S MANUAL PRIOR TO CONNECTING POWER AND USE. MODULAR REFRIGERATOR MODEL #BG179B

More information

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus Operator Guide Publication No. OI 3439-1/97-Eng KODAK Automixer II Plus ii PLEASE NOTE The information contained herein is based on the experience and knowledge relating to the subject matter gained by

More information

RK/ RK Carbon Monoxide Detector Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual 65-2496RK/65-2499RK Carbon Monoxide Detector Operator s Manual Part Number: 71-0156RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Dry Bath Heating Systems

Dry Bath Heating Systems Dry Bath Heating Systems Instruction Manual N2400-4001 Dry Bath Heating System, Single Block, Digital N2400-4002 Dry Bath Heating System, Dual Block, Digital www.starlabgroup.com DECLARATION OF CONFORMITY

More information

Safe T Net 210. Instruction Manual Part Number Mar2010

Safe T Net 210. Instruction Manual Part Number Mar2010 Safe T Net 210 Instruction Manual Part Number 71-0012 31Mar2010 2007 Thermo Fisher Scientific Inc. All rights reserved. Specifications, terms and pricing are subject to change. Not all products are available

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual 65-2494RK/65-2497RK Oxygen Detector Operator s Manual Part Number: 71-0179RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual RND 560 00155 100W Temperature Controlled Soldering Station Instruction Manual 1 INTRODUCTION Thank you for purchasing this intelligent high power RND lab soldering station the best solution for your soldering

More information

POU Water Dispenser User Manual

POU Water Dispenser User Manual GLACIER POU Water Dispenser User Manual 1 2 3 4 5 6 1.POU Cover 2. Reset Button 3. POU Kit 4. Touch Guard Hot Water Faucet 5. Cold Water Faucet 6. Drip Tray Parts may not appear exactly as shown THANK

More information

Carbon Dioxide Sample-Draw Detector Operator s Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual 35-3001-05-03 Carbon Dioxide Sample-Draw Detector Operator s Manual Part Number: 71-0413 Revision: 0 Released: 8/4/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates StableTemp Digital Hotplates, Stirrers and Stirring Hotplates OPERATION MANUAL AND PARTS LIST Hotplates: Catalog # Size Voltage Top Plate Material 03405-40 7x7 120 Ceramic 03405-45 7x7 230 Ceramic Stirring

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98) 32506 Upholstery and Drapery Cleaner Model No.: 32506 3 gal Extractor Operator and Parts Manual KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U.S.A. FAX: 1-559-673-5725 CUSTOMER SERVICE: 1-800-241-4865 MNL32506

More information

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate Table of Contents Package Contents................ 1 Warranty................ 1 Installation................

More information

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 Torrey Pines Scientific, Inc 2713 Loker Ave. West Carlsbad, CA 92010 Phone: 760-930-9400 Fax:

More information

SimplyClear Pressurized Filter Product Manual

SimplyClear Pressurized Filter Product Manual SimplyClear Pressurized Filter Product Manual For Model: SimplyClear 1250 (Item #130040) Table of Contents: Important Information... 2 Package Contents... 3 Technical Specs... 3 How it Works.................................

More information

GE Healthcare. Mixer M-925. Instructions

GE Healthcare. Mixer M-925. Instructions GE Healthcare Mixer M-925 Instructions Important user information All users must read this entire manual to fully understand the safe use of Mixer M-925. Important! Mixer M-925 is intended for research

More information

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

8070 Mytee Lite. Instructions for. Please read before use. Register your product at  support/register. Instructions for 8070 Mytee Lite Please read before use. Register your product at http://www.mytee.com/ support/register Model # Serial # Form # ADP-8070 06-16 1 GENERAL INFORMATION Dear Customer: Congratulations

More information

TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual

TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual TRIO Rx Portable Ultra- High FAC Decanter Activator Set Instruction Manual Point of use production of activated cleaner and sanitizer/disinfectant Environmentally responsible Effective on hard surfaces

More information

Steam Station IRSG Portable DVD Player

Steam Station IRSG Portable DVD Player Steam Station IRSG2416 7 Portable DVD Player To reduce the risk of fire, injury or electrical shock: Read all the instructions before operating the pump station and keep them for future reference. If you

More information

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector O P E R A T I N G M A N U A L TEK-Mate Refrigerant Leak Detector Declaration Of Conformity This is to certify that this equipment, designed and manufactured by INFICON Inc., 2 Technology Place, East Syracuse,

More information

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02 35-3000RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: 71-0071RK Revision: P1 Released: 7/18/02 RKI Instruments Inc. 1855 Whipple Road Hayward, CA 94544 PH: 800-754-5165 Fax: 510-441-5650

More information

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output Operating Instructions & Parts Manual 1RKT2, 1RKT3, 1RKT4, 1RKT5, 1RKT9 and 1RKU2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the

More information

VA301C CONTROLLER WITH BACnet OPTION

VA301C CONTROLLER WITH BACnet OPTION ORDERING INFORMATION VA301C Controller VA301C-DLC VA301C-DLC-BIP Gas detection controller with data logging, display and plastic housing. Gas detection controller with data logging and display, BACnet/IP

More information

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax TC-324B Manual, Rev. 05.01.31 Single Channel Heater Controller Model TC-324B 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax TC-324B Manual, Rev. 05.01.31 TC-324B

More information

INSTALLATION GUIDE AND OWNER S MANUAL

INSTALLATION GUIDE AND OWNER S MANUAL INSTALLATION GUIDE AND OWNER S MANUAL SINGLE POINT, FLOW CONTROLLED and THERMOSTATIC ELECTRIC INSTANTANEOUS WATER HEATERS BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS HEATER, MAKE

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

30-YEAR LIMITED WARRANTY

30-YEAR LIMITED WARRANTY PROGRESS LIGHTING 30-YEAR LIMITED WARRANTY PROGRESS LIGHTING FAN MOTORS ARE WARRANTED TO THE END USER TO BE FREE OF ELECTRICAL AND/OR MECHANICAL DEFECTS FOR A PERIOD OF 30 (THIRTY) YEARS FROM DATE OF SALE.

More information