Air Circuit Breakers

Size: px
Start display at page:

Download "Air Circuit Breakers"

Transcription

1 Air Circuit Breakers

2 About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience in this field, the Company today enjoys a leadership position in the Indian market with a growing international presence. It offers a complete range of products including powergear, controlgear, industrial automation, building electricals & automation, reactive power management, energy meters, and protective relays. These products conform to Indian and International Standards. Switchgear Factory, Mumbai Switchgear Factory, Ahmednagar

3 Air Circuit Breakers L&T s Air Circuit Breakers ACBs) are specially designed for extreme tropical conditions and have a proven track record of more than 30 years. Presently more than 3,,000 Air Circuit Breakers supplied by L&T are being used for diverse applications. The Air Circuit Breakers provide technologically driven solutions to meet customer needs. Complete selectivity Unique feature of lcu=lcs=lcw for second across the entire range. This ensures complete selectivity for system with time based discrimination. Perfect for Indian conditions Inherent design to perform in extreme tropical conditions. Typical site conditions like high ambient temperature, humidity and dusty environment are best handled by ACBs without compromising on performance and safety. Optimal compactness Designed to ensure Low inherent temperature rise Adequate interface clearances Widest choice of over current protection releases Advance microcontroller based with option of communication & meteringsr7 Micro processor based releasessr8/sr8g/sri Thermomagnetic releasedn Elegant design & rugged construction Common door cutout for entire range Left aligned cutout for all ratings Uniform height and depth for ACBs upto 00 Amp Range to meet every customer s need Various options to choose from Breaking capacity from ka to ka 3 Pole or 4 Pole configuration Fixed or Drawout version Auto or Manual reset mechanism Independent manual or stored energy type, manual or electrically operated mechanism Different terminal orientations : Flat, Horizontal and Vertical

4 User friendly features Front accessible over current release settings, telescopic racking handle and various racking interlocks; no need to open the panel door Unique Maintenance position in drawout type ACBs to facilitate maintenance & inspection without removing ACB from the panel Multitap CTs for enhancing protection range in DN release Wide variety of Amperemetric and Voltmetric releases Fully rated neutral pole for the entire range Lockable sliding shutters to prevent unauthorized access to TRIP and CLOSE push buttons Can be used as an ON / OFF Load Isolator Extendable Electrical Life: By replacing the arcing contacts at site, for all ratings Without changing pole assembly Programmable SICs: Auxiliary contacts in drawout ACBs are programmable for only Service, Only Test, Test and Service, and All Positions Protection releases are easily interchangeable at site Facility for site conversion of manually operated ACBs to electrically operated ACBs Jaws on breaker facilitate ease of maintenance & replacement of contact jaws Safety marked for C, S & H ranges Superior quality engineering grade plastics used for insulation purpose; conforms to Glow wire test Ref: IEC 695) Inbuilt mechanical antipumping to prevent autoreclosing of ACB on persisting faults Inbuilt rating error preventor in drawout ACBs ensure correct rating of drawout portion in corresponding cradle Safety shutters prevent accidental contact with live cradle terminals Variety of Safety Interlocks Easily removable arc chutes without use of any tool Operating voltage ranges from % Un to % Un for shunt release ensures intentional tripping even at high voltage drops during short circuit Transparent safety shutter offers easy inspection of cradle contacts & reduces the maintenance time Conformance to standards IEC 947 Part & ) IS/IEC 947 Part & ) IEC 695 BS EN 947

5 Range Breaking capacities: Icu = Ics = Icw Rated Current 0A 630A 800A A A A 000A 0A 300A 00A 00A 6300A CNCS : E ka ka ka ka ka ka ka Frame CNCS : S ka ka ka ka ka ka ka ka Frame Frame CNCS : C ka ka ka ka ka 55kA ka 95kA 95kA CNCS : H ka ka ka ka ka ka CNCS : H0 ka ka CNCS : H/H ka ka Frame Frame Frame3 Frame4 3

6 Technical Data Sheet Rating A) Type Designation E E S E S C H E S C H E S C H E S C H E S C H S C H S H0 H H0 H C C Rated current A) at C I n Rated operational voltage V), /Hz * U e Rated insulation voltage V), /Hz U i No. of poles 3 3 3/4 3 3/4 3 3/4 3 3/4 3 3/4 3 3/4 3/4 3/4 3/4 3/4 3/4 Rated ultimate short circuit breaking capacity /Hz ka rms) I cu 380/45/0V 690V Rated service short circuit breaking capacity /Hz ka rms) I cs 380/45/0V 690V Rated short time 0.5 sec withstand capacity /Hz ka rms) ** I cw sec 3 sec Rated making capacity /Hz ka peak) I cm 380/45/0V 690V Rated impulse withstand voltage of main circuit kv) U imp Rated impulse withstand voltage of aux. circuit kv) U imp Typical opening time ms) Typical closing time ms) Utilization category B B B B B B B B B B B B Suitability for isolation Fixed x x x x x x x x x x x x x x Draw out x x x x x x x Manual Electrical x x x x x x x Electrical & Mechanical life operating cycles) Electrical life without maintenance Dimensions in mm) Fixed H W 3 Pole 4 Pole D Draw out H W 3 Pole 4 Pole D * Please consult us for application at dc voltages & higher operational voltage upto 690V AC. ** Icw values are indicated based on thermal considerations. While selecting a breaker please ensure that Icw requirement for the application is not more than Ics / Icu at the point of installation. Electrical life = Mechanical life. However, arcing contacts need to be replaced depending upon wear & tear. Please consult us. 5

7 Protection releases Microprocessorbased, Communicationcapable Release SR7 Salient Features True RMS sensing Offers comprehensive protection for overload, short circuit, instantaneous, earth fault and neutral overload High resolution backlit LCD display Intelligent Pretrip alarm to prevent system shutdown Password protected settings and commands MODBUS RTU protocol with intrinsic RS 485 port LED indication for POWER ON, different faults and Pretrip alarm sets of storable protection settings Last 5 trips & 8 Event records with time & date stamping 3 programmable contacts for micro controller failure, for basic fault annunciation 4 relay contacts for indication of exceeding maximum demand, Pretrip alarm and control on breaker closing and opening) Ratingplug for precise protection at lower load currents Autodoubling features to prevent nuisance tripping Selectable I t based current for shorttime and earth fault zones Thermal reflectivity enables faster tripping on recurrent overloads Inbuilt Zone Selective Interlocking Provision for Selfdiagnostic test Conformance to EMI/EMC standards Overload Phase) Neutral Fault Short Circuit Instantaneous Earth Fault Parameter Current Settings A), Ir = In x... Time Delay, Tr sec) at 6 x Ir Pretrip Alarm Settings Thermal Reflectivity Function Current Settings A), In = Irx... Time Delay sec) Current Settings A), Isd = In x... Time Delay, tsd msec) at x In Pretrip Alarm Settings l t Coldload Pickup Coldload Pickup Delay Function Current Settings A), Ii = In x... Function Current Settings A), Ig = In x... Time Delay sec), tg Pretrip Alarm Settings l t Coldload Pickup l t OFF l t ON Screen Abbreviation PICKUP TMStr PREALAR THMMEM FUNC PICKUP DELAY PICKUP DELAY DELAY PREALAR l t COLDPIC CPDLY FUNC PICKUP FUNC PICKUP DELAY PREALAR l t COLDPIC Details 0.4 to.0 In in steps of 0.05 In to 0.95 Ir in steps of 0.05 Ir ON / OFF Same as 'Overload Phase)' to In in steps of 0.5 In to 0.95 Is in steps of 0.05 Is ON / OFF to sec in steps of sec to 6 In in steps of In to 0.6 in steps of 0.05 In for l t ON to 0.6 in steps of 0.0 In for l t OFF to 0 msecs in steps of msec for l t ON to 5 sec in steps of msec for l t OFF 0.5 to 0.95 Ig in steps of 0.05 Ig ON / OFF Factory Settings.0 In 30 sec 0.95 Ir OFF.0 Ir 30 sec In 0 msec 0 msec 0.95 Is Disable sec Enable 6 In Enable 0.6 In 3 sec 0.95 Ig OFF Disable Note: Both Protection Groups & carry the same factory settings. 6

8 Additional Protections Parameter Screen Abbreviation Details Factory Settings Under Current Function FUNC Disable Current Setting A) x In PICKUP 5% to 80% in steps of 5% In 0.8 In Time Delay secs) DELAY to 55 in steps of second second Trip / Alarm MODE Either / Both Alarm Current Unbalance Function FUNC Disable Current Setting A) x In PICKUP % to 95% in steps of 5% In 0. In Time Delay secs) DELAY to in steps of 5 secs.0 secs Over Voltage # Function FUNC Disable Voltage Setting V) Vs = Vn x.. PICKUP % to % in steps of 5% Vn. Vn Time Delay secs) DELAY to in steps of secs 5.0 secs Reset Voltage RSTSET 85% to 98% in steps of % Vs 0.95 Vs Trip / Alarm MODE Either / Both Alarm Under Voltage # Function FUNC Disable Voltage Setting V) Vn x.. PICKUP 45% to % in steps of 5% Vn 0.6 Vn Time Delay secs) DELAY to 5 in steps of secs second Reset Voltage RSTSET % to 5% in steps of % Vs.0 Vs Trip / Alarm MODE Either / Both Alarm Under Frequency # Function FUNC Disable Frequency Setting Hz) PICKUP 45 to Hz for Hz in steps of 0.0Hz 57 to Hz for Hz in steps of 0.0Hz 48.0Hz 59.0Hz Time Delay secs) DELAY to secs in steps of Second 0. secs Drop Off Frequency DRPOFF 0.0 to 0.Hz in steps of Hz Hz Trip / Alarm MODE Either / Both Alarm Over Frequency # Function FUNC Disable Frequency Setting Hz) PICKUP to 55Hz for Hz in steps of 0.0Hz to 6Hz for Hz in steps of 0.0Hz 5.0Hz 6.0Hz Time Delay secs) DELAY o. to secs in steps of second 0. secs Drop Off Frequency DRPOFF 0.0 to 0.Hz in steps of Hz Hz Trip / Alarm MODE Either / Both Alarm Reverse Power # Function FUNC Disable Settings kw) PICKUP 0.0 to 0.4 in steps of 0.0 Pn 0. Pn Time Delay secs) DELAY to in steps of secs.0 secs Trip Alarm MODE Either / Both Alarm Phase Sequence # Function FUNC Disable Settings PICKUP Time Delay secs) DELAY 0 to 5 in steps of 0.5 secs secs Breaker Failure Trip / Alarm Function MODE FUNC Either / Both Alarm Disable Time Delay secs) DELAY 0.05 to secs in steps of 0.0 secs.0 second Maximum Demand Exceed Function Settings kw) FUNC PICKUP kw kw Disable kw Step DELAY kw kw kw i Discrimination i Discrimination Disable # Requires SR7PM module 7

9 Metering Parameter Current Voltage# Frequency # Power Factor # Power # Energy # HarmonicCurrent HarmonicVoltage # Display # Requires SR7PM module Screen Abbreviation I Imax %Load V VphVph F PF kw kvar kva kw kwh kvarh kvah IHAR IHAR I3HAR VHAR VHAR V3HAR Details Phase, Earth and Neutral Maximum running Current per Phase Percent Loading PhaseNeutral PhasePhase System Frequency System Power Factor Active Power per Phase and Total kw) Reactive Power per Phase and Total kvar) Apparent Power per Phase and Total kva) Maximum Demand kw) Total Active Energy kwh) Total Reactive Energy kvarh) Total Apparent Energy kvah) RPhase Current Harmonics YPhase Current Harmonics BPhase Current Harmonics RPhase Voltage Harmonics YPhase Voltage Harmonics BPhase Voltage Harmonics High Resolution Backlit LCD Additional Features Parameter LED Indications Auxiliary Supply Digital Inputs Output Relays Rating Plug Communication Maintenance Indication Event Records 8) Trip Records Testing Supplementary Modules No. of Storable Settings Screen Abbreviation Auxiliary Power ON Overload Short Circuit Instantaneous Earth Fault Neutral Fault Trip Alarm In Multiplier Protocol Link used SelfDiagnostic Test Comunication Module SR7COM) Power Supply Module UNPS) Power Metering Module SR7PM) Relay Module SR7REL) Details 4V DC 4 Nos. 3 Internal + 4 External Relays V AC / 5A, 30V DC / 5A resistive load) MODBUS RTU RS 485 I t based Pickup, Alarm, Trip, Date, Time and Cause of Event, voltage and current readings in all phases Last 5 records with date and time stamping, MODBUS RTU using RS485 Input:6V to V DC, 90 to 300V AC/DC Output:4V DC V AC, 45V AC 4 Relay Outputs Breaker OPEN, Breaker CLOSE, Pre Trip alarm and MD Exceed) 8

10 Protection releases Microprocessor Based Release SRi Salient Features Selfpowered & true RMS sensing Inbuilt Zone Selective Interlocking ZSI) Provision for Selfdiagnostic testwithout tripping the breaker) Switchable thermal memory takes care of residual heat in case of repetitive overloads Multistate LED to indicate Power ON condition Test mode Individual fault annunciation through LEDs Provision for AN module for remote fault indication through LEDs with changeover contact for each kind of fault Direct tripping of breakerreliable tripping with minimum time delay Test kit available for testing the release SRT) Realistic hot and cold curves which take into account integrated heating effect Conformance to EMI/EMC standards Type of Protection Long Time Pickup Current Ir 0.5 to.0 times In Steps : 0., 0., 0., 0.70, 0., 0.80, 0.85, 0.9, 0.95,.00 Setting Range Time Delay 0. to 30 sec. at 6 times Ir Steps : 0., 0.5,,.5,, 3.5, 6,, 7, 30 Sec Short Time Instantaneous Ground Fault* to times In Steps :, 3, 4, 5, 6, 7, 8, 9, to 6 times In Steps :, 3, 4, 6, 8,,, 4, 6, OFF 0. to 0.6 times In Steps : 0., 0.3, 0.4, 0.5, ms to 0 ms Steps : 0,,,, 00,, 300, 0, 0, 0 ms to 0 ms Steps :, 00, 300, 0 ms & OFF In 3 phase, 4 wire system, Neutral CT is required for ground fault protection. Testkit SRT Salient Features TestKit for SR8/SR8G/SRi Releases Operates from 30V AC supply & generates singlephase voltage test signals Tests the release for Phase fault i.e. for long time, short time and instantaneous protection Ground fault protection Test current multiples For phase faults:.5 In, 4.5 In, 6.5 In, 9.5 In, In, 3 In For ground fault: 0.5 In, 0.35 In, 0.45 In, 0.55 In Five 7segments LED display indicates the trip time two places after decimal) 9

11 Protection releases Microprocessor Based Release SR8 & SR8G Salient Features Selfpowered & true RMS sensing Comprehensive protection SR8; Long Time and Short Time SR8G; Long Time, Short Time and Ground fault protection True Hot & Cold characteristics & switchable thermal memory Multistate LED to indicate Power ON condition Test mode Individual fault annunciation through LEDs AN module for remote fault indication through LEDs with changeover contact for each kind of fault Provision for Selfdiagnostic test without tripping the breaker) Test kit SRT) available for testing the releases Conformance to EMI/EMC standards Type of Protection Pickup Current Setting Range Time Delay Long Time Short Time Instantaneous Ground Fault* Ir 0.5 to.0 times In Steps : 0., 0., 0., 0.70, 0., 0.80, 0.85, 0.9, 0.95,.00 to times In Steps :, 3, 4, 5, 6, 7, 8, 9, 6 & In 0. to 0.6 times In Steps : 0., 0.3, 0.4, 0.5, sec at 6 time s Ir 0 to 0 ms Steps : 0,,,, 00,, 300, 0, 0, 0 ms to 0 ms Steps :, 00, 300, 0 ms & OFF * Available in SR8G release only In 3 phase, 4 wire system, Neutral CT is required for ground fault protection. Thermomagnetic Release Type DN DN thermomagnetic release offers reliable protection against overload, short circuit and ground faults via multitap Cts. with ambient temperature compensation 0 0 from 5 C to C Protection Overload Protection Unique individual phase O/L setting adjustment helps to avoid the nuisance tripping of ACBs in unbalance load condition due to single phase loads) on distribution transformer. Long time pickup range: 0. to times In Short Circuit Protection Two taps on CTs working as rating plug) help in selecting operating threshold. Shorttime pickup range: 5.5 to 7.5 times In with minimum impulsion time of 5ms to prevent nuisance tripping due to transients Ground Fault Protection Offered with auxiliary earth fault release module. Groundfault pickup range: 0. to 0.5 times In

12 Protection Characteristic Overload Curve SR7),000 Trip Time s) 30 sec 4 sec 8 sec sec 6 sec 4 sec sec Tolerance: Trip Time: ±0% Short Circuit I t ON SR7),000 sec 0.5 sec Current Multiples x Ir) Trip Time s) Current Multiples x In)

13 Protection Characteristic,000 Short Circuit I t OFF SR7) Trip Time s) Instantaneous SR7) Current Multiples x In) Trip Time s) Current Multiples x In)

14 Protection Characteristic,000 Earth Fault I t ON SR7) Trip Time s) s s Earth Fault I t OFF SR7), Current Multiples x In) Trip Time s) s 0.3s 0.s s Current Multiples x In) 3

15 Protection Characteristic 0 Overload SRi) Trip Time s) Short Circuit SRi) Current Multiples x Ir) Trip Time s) Current Multiples x In) 4

16 Protection Characteristic Ground Fault SRi) Trip Time s) Overload SR8/8G) 0.0 Current Multiples x In) Trip Time s) Current Multiples x Ir) 5

17 Protection Characteristic Short Circuit SR8/8G) Trip Time s) Ground Fault SR8G) Current Multiples x In) Trip Time s) 0.0 Current Multiples x In) 6

18 Protection Characteristic Timecurrent DN) 0.05 Operating Limits }. Thermal Zone of Short Circuit Operation M/M) Trip Time s) M M DN 5ms 0.0 Total Operating Time Min. Impulsion Time Current Multiples x In) 7

19 Wiring Diagram H B 88 anti pumping MV CP NCT 7 7 E F Micro switch for ground fault in DN release Electrical antipumping Under voltage Indication Shunt trip Indication Separate fault Indication Common fault Indication Spring Charging Indication Closing Preventer U/V release Neutral C.T As per order/requirement FCA Limit switchshown in breaker reset condition) R Economy Resistor C Limit switch operates when closing electromagnet is held on C6 Service position microswitch for withdrawable circuit breakersshown in test position) For SRi release P&C unit) Short circuit i/p & o/p Ground fault i/p & o/p Ground i discrimination i discrimination SI, SO GI, GO G C H ECD Only for DC F Internal Wiring FCA B D Electric Charging Device 5 6 E C Closing Coil N R Y B CA x x x x 4 EA/ EA Internal Wiring DN/SR8/SR8G SRi/SR7 8 8 Load Aux NO Aux NC Aux NO Aux NC Aux NO Aux NC Shunt release Aux NC Protection & Control Unit Main Circuit Ref no The above drawing is for EDO breakers. ) For MDO/MF versions Ref no. 3,, are not applicable E, B, C, D, A are applicable only in electrical breakers. ) For EF versions The ref. no., 3, 4, 5, 6, 7, 8, 9, 0, are provided as per customer requirement. CC C6 A R 8

20 Accessories Type Data Lockable Trip Push Button LTPB) Mounted in place of normal trip push button. With this, ACB can be locked in trip condition. For interlocking, LTPBs are offered in the following combinations: 4 different types of keys i.e. AA, BB, CC and DD suitable for I/C & B/C schemes Combination of L, M, N, LM and MN locks, which are suitable for 3 I/C & B/C schemes Combination of K, L, M, N, KL, LM and MN locks, which are suitable for 4 I/C & 3 B/C schemes Combination of J, K, L, M, N, JK, KL, LM and MN locks, which are suitable for 5 I/C & 4 B/C schemes View of the Cradle Locking in Isolated Position LIP) The facility of locking the ACB in Isolated position is available in Drawout ACBs. This is useful to achieve interlocking between Main & Standby source. Similar lock is available as LOCK IN ANY POSITION. Door Interlock Racking Interlock Locking in Isolated Position Door Interlock This ensures: Unless the panel door is closed, breaker cannot be racked in or out Unless the breaker is in Isolated Position, it is not possible to open the panel door Racking Interlock This ensures that breaker cannot be racked in/out unless the ACB is in tripped/open condition. Mechanical Interlock It is possible to provide Mechanical Interlock between two breakers of the same or different ratings in vertical or horizontal configurations. Mechanical interlock is available for ACBs up to 00A. Mechanical interlocking for ACBs in vertical configuration can be provided by links or by flexible cables. Same for horizontal configuration can be provided by flexible cables. 9

21 Accessories Type Data C Common indication of tripping due to overload, short circuit and ground faults. Provided by microswitch C fitted inside the ACB Available as an option in all releases C Separate indication of tripping due to overload, short circuit and ground faults. For release type DN, this is provided by microswitch C & C C fitted inside release) ANAnnunciator Module Remote indication of tripping due to overload, short circuit and ground faults. Can be used with releases type SR8/SR8G/SRi Individual fault indication provided by three separate LEDs for Long time faults Short time fault/instantaneous fault Ground fault One potential free contact rated 5A at 30V AC available for each type of fault Flush mounting on panel HWD=9mm x 46mm x mm) Operating voltage: V AC C5 Indication for operation of shunt release or undervoltage release. Provided by microswitch C5 fitted on the shunt release or undervoltage release 0

22 Accessories Type Data Technical Data Shunt Release For remote tripping of the breaker Shunt release coil is short time rated and is disconnected from the circuit by an auxiliary contact when the ACB trips Refer to wiring diagram) Low power consumption Two types available: EA for DC application EA for AC application Type of Release EA EA Rated Operational voltage Ue) AC 45 AC 4V DC 48V DC DC 0 DC Power consumption at pickup 800 VA 800 VA 3 W 5 W 45 W 30 W Note : Other voltages available on request Operation Limit 30% Ue 30% Ue Undervoltage Release Type MV With no intentional time delay Notes: When undervoltage release is provided, the ACB can be closed only when supply is available to the undervoltage release. Parameter Rated Operational voltage Ue) Pick up V) Drop OFF V) Consumption VA) Specification V & 45V: Hz 0V & 45V: Hz 80% Ue 35% Ue Pick up 3 VA Hold on VA Watt loss 6 W Closing Release Closing release remotely closes the circuit breaker if the mechanism spring is already charged. Rated operational voltage Ue) V AC V AC 0V AC V DC 0V DC Power consumption Pickup 30VA 300W Holdup VA W 4V DC 3W W Range of operation 85% Ue Spring charging Motor Electrical charging device automatically charges the mechanism spring of the circuitbreaker. After circuitbreaker closing, the geared motor immediately recharges the closing spring. Thus instantaneous reclosing of the circuitbreaker is possible following opening operation. Rated operational voltage Ue) V AC V DC 0V DC Power consumption 30VA 54W Range of operation 85% Ue Auxiliary Contacts Two combinations available: NO + NC 6 NO + 6 NC Electrical circuit Resistive Voltage V) 4 to 45 AC V AC Rated current A) 6. Nonresistive 4 to 45 AC V AC 6.0 # # L/R = 5ms with two contacts in series

23 Overall Dimensions Fixed Breakers For 800A to 0A / C/H For Metallic Components 36 min 36 min A min min 9 3 min For Insulating Sheet 0 min min To Remove Arc Chute 7 Door Bezel Earthing Terminal HolesØ min D E F E D Ratings CN CS Dimensions mm) A D E F Weight kg.) Manual Electrical 800/A /A C/H C/H /A /A C/H C/H /0A C/H /0A C/H For CNCS...E 0A000A 3 min Insulator +.0 min 36 min min 3.5 min Rating Type X Y Holes Ø 385 X X 0E E / 000E Y Note : All Dimensions are in mm.

24 Overall Dimensions Fixed Breakers Terminal HolesØ HolesØ to 000E & 800///C/H 000/0C/H Terminal Connections Terminal for //000/0C/H Bezel Fixing Plan for all Fixed Breakers 33 Hinge Hinge Terminal for 800/C/H HolesØ min min Note: A = 89 for 00C A = 9 for other fixed ACBs Door Cutout Door Drilling for Bezel Fixing Plan Bezel Note : All Dimensions are in mm. 3

25 Overall Dimensions Drawout Breakers For 630A to 300A C/H/S /, 300H/00H / For Metallic Components A max min For Insulating Sheet min 00 min Isolated Position 5 Test Position Service Position Door 6 7 Bezel * M min. 8.9 max min D E F E D 64.5 Earthing Terminal 5 *Terminal For 630/800/ C/H/S, /0S & 000C/H *Terminal for //0C/H & 800/H *Terminal for for 300S *Terminal for 300H0/H & 00H0/H Ratings CN CS A Dimensions mm) D E F 630/800/A C/H/S 000A S /A C/H/S 630/800/A C/H/S 000A S /A C/H/S 000/0A 0/300A C/H S /0A 0/300A C/H S A 00A H0/H H0/H A 00A H0/H H0/H Note : All Dimensions are in mm. 4

26 Overall Dimensions Drawout Breakers Flat Terminal Connections.5 4 slots 8.5 x Slots 8.5 x Slots 8.5 x C & 630 S 800 H, /C/H & 000S 000C HolesØ4 6 HolesØ HolesØ C/H & 000H 6 Holes Ø4 0S 300S 300H0/H & 00H0/H.5 For 00C/6300C / A max For Metallic Components 0 min For Insulating Sheet min 00 min 5 Isolated Position Test Position Service Position 6 Door 7 Bezel M min 8.9 max min D E F E D 8 HolesØ Earthing Terminal Terminal Connections 00C/6300C Ratings Dimensions mm) A D E F 00A C A C A C A C Note : All Dimensions are in mm. 5

27 Overall Dimensions Mounting Details For Horizontal Mounting of all Drawout Breakers For 630A to 300A C/H/ S / 300 H0/H, 00 H0/H / HolesØ 4 Ratings Type G mm) 800A A C/H 80.3 *G Front 630A 000A 800A A S C/H A 000A S / 0A 000 / 0A 0 / 300A 0 / 300A C/H C/H S S For 00C/6300C / 59 5 HolesØ 5 300A 300A 00A 00A H0 / H H0 / H H0 / H H0 / H Bezel Fixing Plan for all Drawout Breakers 6 HolesØ Hinge Hinge / 6300A C / 6300A C 3 Base of Cradle min A 94 5 min Door Cutout Note: For 00A C /, 00C/6300C / ACB, A = 8.5 For other Drawout Breakers A = 79.5 Door Drilling for Bezel Fixing Plan Bezel Note : All Dimensions are in mm. 6

28 Overall Dimensions Terminals Horizontal Terminals Rear Side C C/H & 800/H 000C 0C/H & 000H HolesØ4 3 HolesØ4 4 HolesØ4 6 HolesØ4 V S W U.0 4 HolesØT O P N R X M Vertical Terminals Top Side View Rear View Ratings M N P Q R S T U V W X 630 S & 800 C 000 S & C/H 800 H 000C 0 C/H 000 H Note : ) All Dimensions are in mm. ) Consult us for other Terminal Orientations. 7

29 Overall Dimensions Terminals Vertical Terminals V ØT U Q P S W X M N R 5 The dimensions for 300 H/H0 and 00 H0 are as under: Ratings M N P Q R S T U V W X 300 H/H0 & 00 H Note : ) All Dimensions are in mm. ) Consult us for other Terminal Orientations. 8

30

31 Electrical Standard Products ESP) Branch Offices: REGISTERED OFFICE AND HEAD OFFICE L&T House, Ballard Estate P. O. Box 78 Mumbai 0 00 Tel: 0656 Fax: Website: ELECTRICAL STANDARD PRODUCTS ESP), Sakar Complex I Opp. Gandhigram Rly. Station Ashram Road Ahmedabad Tel: Fax: espahm@lntebg.com 38, Cubbon Road, P. O. Box 98 Bangalore 5 00 Tel: 0800 / 034 Fax: espblr@lntebg.com 3/, Zone II Maharana Pratap Nagar Bhopal 46 0 Tel: / 05 / 08 / 3 / 7 / 9 Fax: espbho@lntebg.com Plot No. 559, Annapurna Complex Lewis Road Bhubaneswar 04 Tel: , Fax: espbbi@lntebg.com SCO 3, Sector 6D Madhya Marg, P. O. Box 4 Chandigarh 09 Tel: , Fax: espchd@lntebg.com L&T Construction Campus TC Building, II Floor MountPoonamallee Road Manapakkam Chennai Tel: Fax: espmaa@lntebg.com 67, Appuswamy Road Post Bag 756 Opp. Nirmala College Coimbatore Tel: / / 5 Fax: espcbe@lntebg.com Khairasol, Degaul Avenue Durgapur 73 Tel: , , Fax: espdgp@lntebg.com Milanpur Road, Bamuni Maidan Guwahati 78 0 Tel: / Fax: hazrasudipto@lntebg.com II Floor, Vasantha Chambers 573, Fateh Maidan Road Hyderabad Tel: Fax: esphyd@lntebg.com Monarch Building, st Floor D36 & 37, Amrapali Marg Vaishali Nagar Jaipur 30 0 Tel: to 8 Fax: espjai@lntebg.com Akashdeep Plaza, nd Floor P. O. Golmuri Jamshedpur Jharkhand Tel: / 38 Fax: espjam@lntebg.com Skybright Bldg; M. G. Road Ravipuram Junction, Ernakulam Kochi Tel: / 4 / 5 / 7 Fax: espcok@lntebg.com 3B, Shakespeare Sarani Kolkata Tel: / 3 / 4 Fax: / 87 espccu@lntebg.com A8, Indira Nagar, Faizabad Road Lucknow 6 06 Tel: /04 Fax: esplko@lntebg.com No: 73, Karpaga Nagar, 8th Street K. Pudur Madurai Tel: , 568 Fax: espmdu@lntebg.com EBG North Wing OfficeLevel Gate 7, Powai Campus Mumbai 0 07 Tel: / 737 / 56 Fax: espbom@lntebg.com, Shivaji Nagar North Ambazari Road Nagpur 4 0 Tel: 070 / 3 Fax: 0700 / 30 espnag@lntebg.com 3, Shivaji Marg P. O. Box 63 New Delhi 05 Tel: / 5 / 6 Fax: espdel@lntebg.com L&T House P. O. Box 9 9/, Dhole Patil Road Pune 4 00 Tel: Fax: / esppnq@lntebg.com Crystal Tower, Plot No. 6/ 4th Floor, G. E. Road Telibandha Raipur Tel: espraipur@lntebg.com 3rd Floor Vishwakarma Chambers Majura Gate, Ring Road Surat Tel: Fax: espsur@lntebg.com Radhadaya Complex Old Padra Road Near Charotar Society Vadodara Tel: / / Fax: espbar@lntebg.com 4886, Dwarakanagar Visakhapatnam Tel: to 30 Fax: espviz@lntebg.com Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here. Larsen & Toubro Limited Electrical Standard Products Powai Campus, Mumbai 0 07 Customer Interaction Center CIC) BSNL / MTNL toll free) : Reliance toll free) : Tel : , Fax : cic@lntebg.com Website : SP 437 R4 8033

Air Circuit Breakers

Air Circuit Breakers Air Circuit reakers About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Moulded case circuit brakers

Moulded case circuit brakers Moulded case circuit brakers CONTENT Range 1 Protection Releases 2 Salient Features 5 Accessories 7 Widest Range 10 Time Current Characteristics 12 Overall Dimensions 14 SN4 SN3 SN2 SN1 3 RANGE SN1 Rated

More information

Save Lives, Protect Property with Intelligent Fire alarm systems from L&T

Save Lives, Protect Property with Intelligent Fire alarm systems from L&T Save Lives, Protect Property with Intelligent Fire alarm systems from L&T The highest level of fire safety. About Us Larsen & Toubro is a technology-driven company that infuses engineering with imagination.

More information

Welcome to Hager Presentation

Welcome to Hager Presentation Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of

More information

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current

More information

Description (Data Point Name) Unit Size

Description (Data Point Name) Unit Size AC-PRO-II Communications Modbus Register Map Document Revision 2.0 Firmware v2.0 AC-PRO-II: Registers 7000 7019: Output Coils 7020 7099: Information 7107 7199: User settings (can be set using Modbus Communications)

More information

Ductable Range of Air Conditioners

Ductable Range of Air Conditioners Ductable Range of Air Conditioners The world is witnessing growth at a breakneck speed. The upsurge in economic and social activities has led to rampant use of natural resources like water, minerals, energy,

More information

Guide Specification Model CTG Automatic Transfer Switch

Guide Specification Model CTG Automatic Transfer Switch Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production

More information

Due to its inherent characteristics, Screw Compressor has the highest volumetric efficiency, de-rating at higher temperature is negligible.

Due to its inherent characteristics, Screw Compressor has the highest volumetric efficiency, de-rating at higher temperature is negligible. Blue Star, India s preferred airconditioning company has been providing expert cooling solutions for over six decades. It is with this expertise Blue Star brings to you a wide range of Air Cooled Screw

More information

Screw Chillers. High on reliability. Low on operating cost.

Screw Chillers. High on reliability. Low on operating cost. Screw Chillers High on reliability. Low on operating cost. Blue Star, India s preferred airconditioning company has been providing expert cooling solutions for over six decades. It is with this expertise

More information

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication

More information

High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series

High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series NEW UNIQUE LCD CONTROLLER THE VOLTAS INTELLISYS RANGE Aero, Thermo and Tropico Series are High-performance Packaged & Ductable

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

EARTH LEAKAGE RELAY. User Manual - Issue 1.0 Earth Leakage Relay www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters EARTH

More information

1.Application. 2.Main Technical Specifications B-10

1.Application. 2.Main Technical Specifications B-10 NS Series Moulded Case Circuit Breaker 1.Application NS series moulded case circuit breaker is one of breaker which adopts international advanced design, manufacture technology to develop. The rated insulating

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Tough on Hard Water. Built for a longer life.

Tough on Hard Water. Built for a longer life. Tough on Hard Water. Built for a longer life. Electric Water Heaters Range 2016 HAVELLS today is known for high quality products & premium manufacturing infrastructure. This philosophy of providing its

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Automation Solution for

Automation Solution for Automation Solution for Commercial and Residential Buildings Switchgear Training Center, Coonoor Powai Campus, Mumbai Switchgear Training Center, Lucknow Ahmednagar Campus Switchgear Training Center, Pune

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:

More information

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional

More information

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

Item Number Description Price. Accessories  Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22 DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,

More information

Table of Contents. Protective Relays

Table of Contents. Protective Relays Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

SENTINEL D - Fault Passage Monitoring

SENTINEL D - Fault Passage Monitoring SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen

More information

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits 01 VAMP 120 & 121 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work

More information

Deep Freezers, Bottle Coolers Milk Coolers and Visi Coolers

Deep Freezers, Bottle Coolers Milk Coolers and Visi Coolers Deep Freezers, Bottle Coolers Milk Coolers and Visi Coolers Unmatched Cooling. Unmatched Freezing. From cooling to freezing. The best solutions from the Expert. Blue Star, being India s leading airconditioning

More information

Operation and use. Functions and characteristics

Operation and use. Functions and characteristics Operation and use Function Vigirex relays measure the earth-leakage current in an electrical installation via their associated toroids. Vigirex relays may be used for: b residual-current protection (RH10,

More information

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame Product Selection 225 A, I-Frame Assembled 225 A I-Frame Interrupting Rating/Breaking Capacity Thermal-Magnetic Circuit Breakers Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [ka] Thermal-Magnetic,

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

Family of motor protection

Family of motor protection Family of motor protection & control relays Totally protect all induction motors Reduce motor downtime SOLCON MPC 2000 Incorporationg similar motor protection features to the MPR 2000 and 45 programmable

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information

QA(13) - Series Miniature Circuit Breakers

QA(13) - Series Miniature Circuit Breakers 1 pole 2 pole 3 pole 3 + N Features AC Circuit Breaker Hydraulic-Magnetic technology 100% rating capability, independent of ambient temperature VC 8036 compliant (SANS 556-1) VDE approved, CE certified

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

B C D I H E F. Important instructions. For house hold use only

B C D I H E F. Important instructions. For house hold use only Room Heater Oil Filled Radiator 9 fins with fan- 230V AC, 50 Hz Single Phase, 2500 W 11 fins with fan- 230V AC, 50 Hz Single Phase, 2900 W 13 fins with fan- 230V AC, 50 Hz Single Phase, 2900 W 1 SPECIFICATION

More information

Speciality Cooling Products

Speciality Cooling Products Speciality Cooling Products For special refrigeration needs Blue Star, India s leading airconditioning and refrigeration company brings you speciality refrigeration products that cater to your special

More information

Comforter PTC heater 230V AC 50Hz Single Phase, 2000 W

Comforter PTC heater 230V AC 50Hz Single Phase, 2000 W Comforter PTC heater 230V AC 50Hz Single Phase, 2000 W Room Heater PRODUCT DESCRIPTION Power Knob Outer cover Handle Temperature control knob Airvent Power indicator IMPORTANT INSTRUCTIONS For House hold

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Scroll Chillers Reliable and energy efficient chillers from the Experts _Scroll Chiller_BrochureV13.indd 1

Scroll Chillers Reliable and energy efficient chillers from the Experts _Scroll Chiller_BrochureV13.indd 1 Scroll Chillers Reliable and energy efficient chillers from the Experts 249200318_Scroll Chiller_BrochureV13.indd 1 25-04-2018 14:56:23 Blue Star, India s largest central air conditioning company, has

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Annunciator unit. Application

Annunciator unit. Application Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT

More information

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

Invest in. Profitability

Invest in. Profitability Invest in Training Enhance Profitability Training Calendar April 0 to March 06 TRAINING PROGRAMME DETAILS PROGRAM CODE TRAINING PROGRAM NO. OF DAYS PROGRAM CONTENTS USEFUL FOR INVESTMENT ` LT0 SELECTION

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7 SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

PRECISION LIGHTING FOR PRISTINE MOMENTS!

PRECISION LIGHTING FOR PRISTINE MOMENTS! BRANCH OFFICES NORTH REGION Chandigarh Tel.: 0172-5103322 Delhi Tel.: 011-66416100 Jaipur Tel.: 0141-2388240 Lucknow Tel.: 0522-4938900-30 Noida Tel.: 0120-4040400 EAST REGION Bhubaneswar Tel.: 0674-2390697,

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

TE809-Ats Instructions Manual

TE809-Ats Instructions Manual TE809-Ats Instructions Manual Project: v2.0 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is designed to put

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

AQ 100 Series. Arc Flash Protection System

AQ 100 Series. Arc Flash Protection System AQ 100 Series Arc Flash Protection System THE CONSEQUENCES OF AN ARC FAULT IN HIGH VOLTAGE SWITCHGEAR THE CONSEQUENCES OF AN ARC FAULT IN OIL-FILLED SWITCHGEAR Arc Phenomena Arc Phenomena Arc fault - facts

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE SBP1000-61 FTA1000 Full Voltage Starting Electric Fire Pump Controllers Product Description Description Firetrol FTA1000 Full Voltage Fire Pump Controllers

More information

Room thermostats with LCD for wall mounting

Room thermostats with LCD for wall mounting s 3 181 RDG100 / RDG110 RDG140 / RDG100 RDG100/H Room thermostats with LCD for wall mounting for fan coil unit applications for universal applications for use with compressors in dx type equipment RDG1

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Electrical installation solutions for buildings Technical details Energy efficiency

Electrical installation solutions for buildings Technical details Energy efficiency /1 Electrical installation solutions for buildings Technical details Energy efficiency Index Multimeters and network analyser /2 DMTME multimeters /5 ANR Network analyser / M2M Network analyser /9 EQ meters

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive

More information

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex. Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C 3 H 2 Gas leak testing Over and over again, devastating explosions and fires are caused

More information

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx: UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK 40 Dale Street West Babylon, NY 11704 Ph: 631-753-9550 Fx: 631-753-9560 www.unionconnector.com Emergency Automatic Transfer System STANDARD SPECIFICATIONS

More information

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Pure Sine Wave Modular Technology Modular AC System Evenlite s LiteMinder Central System provides an innovative Emergency Lighting

More information

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional

More information

EKL3 short circuit and earth fault indicator

EKL3 short circuit and earth fault indicator EKL3 short circuit and earth fault indicator Summary EKL3 short circuit grounding fault indicators are mainly used in various Ring Main Units(RMU), high-voltage switchgears and cable branch units to ascertain

More information

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N) OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N) MRM PROCOM Pvt Ltd An ISO-9001-2008 certified organization Works: Plot No. 20-21, Sector 59, Phase II, Faridabad, Haryana -121004 Ph: 0129-4700400

More information

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description September 2007 NG-Frame 400 s NG-Frame Technical Data and Specifications Table -60. UL 489/IEC 60947-2 Interrupting Capacity s Circuit Breaker Type Interrupting Capacity (ka Symmetrical s) Volts ac (50/60

More information

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

SPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No.

SPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No. SPEF 3A2 C Fault indicator User s manual and Technical description SPA f n = 50Hz x 60Hz U aux =24V- REGISTERS 0 1 I L1 [ A] 2 I L2 [ A] 3 I L3 [ A] 4 t ( I > )[%] 5 I o [ A] 6 t ( I o > )[%] 7 I [%] 8

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. 7PG17 XR105, XR106 and XR107, XR205 and XR206 Interposing

More information

TraceNet ECM Series Control System

TraceNet ECM Series Control System TraceNet ECM Series Control System ECM Operating Guide Thermon Manufacturing Company TraceNet is a registered trademark of Thermon Manufacturing Company. ECM Operating Guide 2014, 2015 Thermon Manufacturing

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

Operating Manual RCM420

Operating Manual RCM420 Operating Manual RCM420 Residual current monitor for AC current monitoring in TN and TT systems Software version: D240 V1.2x TGH1410en/03.2012 Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany

More information