1 Air Circuit reakers
2 About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, which forms part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of eperience in this field, the Company today enjoys a leadership position in the Indian market with growing presence in international markets. It offers a complete range of products including controlgear, powergear, motor starters, energy meters, wires and host of other accessories. Most of our product lines conform to international standards, carry markings and are certified. Switchgear Factory, Mumbai Switchgear Factory, Ahmednagar
3 Air Circuit reakers L&T s Air Circuit reakers (ACs) are specially designed for etreme tropical conditions and have a proven track record more than 30 years. Presently more than 3,00,000 Air Circuit reakers supplied by L&T are being used for diverse applications. The Air Circuit reakers provide technologically driven solutions to meet customer needs. Complete selectivity Unique feature of lcu=lcs=lcw for 1 second across the entire range. This ensures complete selectivity for system with time based discrimination. Perfect for Indian conditions Inherent design to perform in etreme tropical conditions. Typical site conditions like high ambient temperature, humidity and dusty environment are best handled by ACs without compromising on performance and safety. Optimal compactness Designed to ensure Low inherent temperature rise Adequate interface clearances Widest choice of over current protection releases Advance microcontroller based with option of communication & meteringsr71 Micro processor based releasessr1i/sr18/sr18g Thermomagnetic releasedn1 Elegant design & rugged construction Common door cutout for entire range Left aligned cutout for all ratings Uniform height and depth for ACs up to 00 Amp Range to meet every customer s need Various options to choose from reaking capacity from 35kA to 100kA 3 Pole or Pole configuration Fied or Drawout version Auto or Manual reset mechanism Independent manual or stored energy type manual or electrically operated mechanism Different terminal orientations : Flat, Horizontal and Vertical 1
4 User friendly features Front accessible over current release settings, telescopic racking handle and various racking interlocks; no need to open the panel door Unique Maintenance position in drawout type ACs to facilitate maintenance & inspection without removing AC from the panel Multitap CTs for enhancing protection range for eample: 300A. AC can be set to have a thermal protection from 800A Wide variety of Amperemetric and Voltmetric releases Fully rated neutral pole for the entire range Lockable sliding shutters to prevent unauthorized access to TRIP and CLOSE push buttons Can be used as an ON / OFF Load Isolator Etendable Electrical Life: y replacing the arcing contacts at site, for all ratings Without changing pole assembly Programmable SICs: Auiliary contacts in drawout ACs are programmable for only Service, Only Test, Test and Service, and All Positions Unique gasket for IP5 protection Protection releases are easily interchangeable at site Facility for site conversion of manually operated ACs to electrically operated ACs Safety marked for C, S & H ranges Superior quality engineering grade plastics used for insulation purpose; conforms to Glow wire test (Ref: IEC 6951) Inbuilt mechanical antipumping for electrically operated ACs prevent auto reclosing of AC on fault Inbuilt rating error preventor in drawout ACs ensure correct rating of drawout porton in corresponding cradle Safety shutters prevent accidental contact with live cradle terminals Variety of Safety Interlocks (Refer to page no. 1) Easily removable arc chutes without use of any tool Operating voltage ranges from 10% Un to 110% Un for shunt release ensures intentional tripping even at high voltage drops during short circuit Conformance to standards IEC 97 (Part 1 & ) IS/IEC 97 (Part 1 & ) IEC S EN 97
5 Product Certification 3
6 Technical Data Sheet Rating (A) Type Designation E E E C H E C H E C H E C H E C H C H H0 H1 H0 H C C Rated current (A) at C I n Rated operational voltage (V), /Hz * U e Rated insulation voltage (V), /Hz U i No. of poles 3 3 3/ 3 3/ 3 3/ 3 3/ 3 3/ 3 3/ 3/ 3/ 3/ 3/ 3/ Rated ultimate short circuit breaking I cu 380/15/0V capacity /Hz (ka rms) 6/690V Rated service short circuit breaking I cs 380/15/0V capacity /Hz (ka rms) 6/690V Rated short time 0.5 sec withstand capacity ** I cw 1 sec /Hz (ka rms) 3 sec Rated making capacity I cm 380/15/0V /Hz (ka peak) 6/690V Rated impulse withstand voltage U imp of main circuit (kv) Rated impulse withstand voltage U imp of au. circuit (kv) Typical opening time (ms) Typical closing time (ms) Utilization category Suitability for isolation Fied Draw out Manual Electrical Electrical & Mechanical life (operating cycles) Electrical life without maintenance Dimensions (in mm) Fied H W 3 Pole Pole D Draw out H W 3 Pole Pole D * Please consult us for application at dc voltages & higher operational voltage upto V ac ** Icw values are indicated based on thermal considerations. While selecting a breaker please ensure that Icw requirement for the application is not more than Ics / Icu at the point of installation. Electrical life = Mechanical life. However, arcing contacts need to be replaced depending upon wear. Please consult us. 5
7 Protection releases Microprocessorbased, Communicationcapable Release SR71 Salient Features Microcontroller based RMS sensing Offers comprehensive protection for overload, short circuit, instantaneous, earth fault and neutral overload High resolution backlit LCD display Intelligent Pretrip alarm to prevent system shutdown Password protected setting and commands MODUS RTU protocol Intrinsic RS 85 port Total breaker control and monitoring through PC LED indication for POWER ON, different faults and Pretrip alarm sets of storable protection setting Nonvolatile memory to store last 5 trips 8 Event recording with time & date stamping 3 programmable contacts1 for micro controller failure, for basic fault annunciation relay contacts for indication of eceeding maimum demand, Pretrip alarm and control on breaker (closing and opening) Autodoubling features to prevent nuisance tripping Selectable I t based current for shorttime and earth fault zones Thermal reflectivity enables faster tripping on recurrent overloads Intelligent discrimination Selfdiagnostic and monitoring with tricolour LED indication Conformance to EMC standards Parameter Screen Abbreviation Details Factory Settings 6 Overload (Phase) Neutral Fault Short Circuit Instantaneous Earth Fault Current Settings (A), Ir = In... Time Delay, Tr (sec) at 6 Ir Pretrip Alarm Settings Thermal Reflectivity Current Settings (A), In = Ir... Time Delay (sec) Current Settings (A), Is = In... Time Delay, Ts (msec) at 10 In Pretrip Alarm Settings l t Coldload Pickup Coldload Pickup Delay Current Settings (A), Ip = In... Current Settings (A), Ig = In... Time Delay (sec), Td Pretrip Alarm Settings l t Coldload Pickup l t OFF l t ON TMStr PREALAR THMMEM PREALAR l t COLDPIC CP_DLY PREALAR l t COLDPIC 0. to 1.0 In in steps of 0.05 In to 0.95 Ir in steps of 0.05 Ir ON / OFF Same as 'Overload (Phase)' to 10 In in steps of 0.5 In to 0.95 Is in steps of 0.05 Is ON / OFF 0.1 to 10 sec in steps of 0.1 sec to 16 In in steps of 0.1 In 0.1 to 0.6 in steps of 0.05 In for l t ON 0.1 to 0.6 in steps of 0.01 In for l t OFF 100 to 0 msecs in steps of 100 msec for l t ON 0.1 to 5 sec in steps of 100 msec for l t OFF 0.5 to 0.95 Ig in steps of 0.05 Ig ON / OFF 1.0 In 30 sec 0.95 Ir OFF 1.0 Ir 30 sec 10 In 0 msec 0 msec 0.95 Is 0.1 sec Enable 16 In Enable 0.6 In 3 sec 0.95 Ig OFF Note: oth Protection Groups 1 & carry the same factory settings.
8 Additional Protections Parameter Screen Abbreviation Details Factory Settings Under Current Current Setting (A) In 15% to 80% in steps of 5% In 0.8 In Time Delay (secs) 1 to 55 in steps of 1 second 1 second Trip / Alarm MODE Either / oth Alarm Current Unbalance Current Setting (A) In 10% to 95% in steps of 5% In 0. In Time Delay (secs) 1 to 10 in steps of 5 secs.0 secs Over Voltage# Voltage Setting (V) Vs = Vn.. % to 1% in steps of 5% Vn 1. Vn Time Delay (secs) 0.1 to 100 in steps of 0.1 secs 5.0 secs Reset Voltage RSTSET 85% to 98% in steps of 1% Vs 0.95 Vs Trip / Alarm MODE Either / oth Alarm Under Voltage# Voltage Setting (V) Vn.. 5% to % in steps of 5% Vn 0.6 Vn Time Delay (secs) 0.1 to 5 in steps of 0.1 secs 1 second Reset Voltage RSTSET 10% to 115% in steps of 1% Vs 1.0 Vs Trip / Alarm MODE Either / oth Alarm Under Frequency# Frequency Setting (Hz) 5 to Hz for Hz in steps of 0.01Hz 57 to Hz for Hz in steps of 0.01Hz 8.0Hz 59.0Hz Time Delay (secs) 0.1 to 100 secs in steps of 0.1 Second 0. secs Drop Off Frequency DRPOFF 0.0 to 0.10Hz in steps of 0.1Hz 0.1Hz Trip / Alarm MODE Either / oth Alarm Over Frequency# Frequency Setting (Hz) to 55Hz for Hz in steps of 0.01Hz to 6Hz for Hz in steps of 0.01Hz 5.0Hz 61.0Hz Time Delay (secs) o.1 to 100 secs in steps of 0.1 second 0. secs Drop Off Frequency DRPOFF 0.0 to 0.10Hz in steps of 0.1Hz 0.1Hz Trip / Alarm MODE Either / oth Alarm Reverse Power# Settings (kw) 0.0 to 0. in steps of 0.01 Pn 0. Pn Time Delay (secs) 1 to 100 in steps of 0.1 secs.0 secs Trip Alarm MODE Either / oth Alarm Phase Sequence# Settings Time Delay (secs) 0 to 5 in steps of 0.5 secs secs reaker Failure Trip / Alarm MODE Either / oth Alarm Time Delay (secs) 0.05 to secs in steps of 0.01 secs 1.0 second Maimum Demand Eceed Settings (kw) kw 10 kw 100 kw Step 10 kw kw 10 kw i Discrimination i Discrimination # Requires SR71PM module 7
9 Metering Parameter Screen Abbreviation Details Current Voltage# Frequency# Power Factor# Power# Energy# HarmonicCurrent HarmonicVoltage# Display # Requires SR71PM module Additional Features I Ima %Load V VphVph F PF kw kvar kva kw kwh kvarh kvah I1HAR IHAR I3HAR V1HAR VHAR V3HAR Phase, Earth and Neutral Maimum running Current per Phase Percent Loading PhaseNeutral PhasePhase System Frequency System Power Factor Active Power per Phase and Total (kw) Reactive Power per Phase and Total (kvar) Apparent Power per Phase and Total (kva) Maimum Demand (kw) Total Active Energy (kwh) Total Reactive Energy (kvarh) Total Apparent Energy (kvah) RPhase Current Harmonics YPhase Current Harmonics Phase Current Harmonics RPhase Voltage Harmonics YPhase Voltage Harmonics Phase Voltage Harmonics High Resolution acklit LCD Parameter LED Indications Auiliary Supply Digital Inputs Auiliary Power ON Overload Short Circuit Instantaneous Earth Fault Neutral Fault Trip Alarm V DC Nos. Details Output Relays 3 Internal + Eternal Relays 8 Rating Plug Communication Maintenance Indication Event Records Trip Records Testing Supplementary Modules No. of Storable Settings In Multiplier Protocol Link used SelfDiagnostic Test Relay Module Power Supply Module Communication Module V AC / 5A, 30V DC / 5A (resistive load) MODUS RTU RS 85 I t based Pickup, Alarm, Trip, Date, Time and Cause of Event Last 5 records with date and time stamping, voltage and current readings in all phases Relay Outputs V DC Output MODUS RTU
10 Protection releases Microprocessor ased Release SR1i Salient Features Selfpowered True RMS sensing Zone selective interlocking on short circuit and ground faults reduces dynamic and thermal stress on the system Selfdiagnostic and selfcorrecting facility to monitor its own performance Facility for default protection setting Switchable thermal memory takes care of residual heat in case of repetitive overloads Multistate LED to indicate Power ON condition Test mode Microprocessor unhealthy condition Individual fault annunciation through LEDs On load testing release possible through TEST button (without tripping the breaker) AN1 module for remote fault indication through LEDs with changeover contact for each kind of fault Direct tripping of breakerreliable tripping with minimum time delay test kit available for testing the release (SRT) Realistic hot and cold curves which take into account integrated heating effect Conformance to EMI/EMC standards Type of Protection Long Time Short Time Instantaneous Pickup Current Ir 0.5 to 1.0 times In Steps : 0., 0., 0., 0.70, 0., 0.80, 0.85, 0.9, 0.95, 1.00 to 10 times In Steps :, 3,, 5, 6, 7, 8, 9, 10 to 16 times In Steps :, 3,, 6, 8, 10,, 1, 16, MAX (infinity) Setting Range Time Delay 0. to 30 sec. at 6 times Ir Steps : 0., 0.5, 1, 1.5,, 3.5, 6,, 17, 30 Sec 0 ms to 0 ms Steps : 0,, 100, 1, 00,, 300, 0, 0, 0 ms Ground Fault 0. to 0.6 times In Steps : 0., 0.3, 0., 0.5, to 0 ms Steps : 100, 00, 300, 0 ms & infinity In 3 phase, wire system, Neutral CT is required for ground fault protection. 9
11 Protection releases Microprocessor ased Release SR18 & SR18G Salient Features Selfpowered True RMS sensing Comprehensive protection SR18; Long Time and Short Time SR18G; Long Time, Short Time and Ground fault protection True Hot & Cold characteristics Switchable thermal memory takes care of residual heat in case of repetitive overloads Facility to have default protection settings Suitable for 800A to 6300A Multistate LED to indicate Power ON condition Test mode Microprocessor unhealthy condition Individual fault annunciation through LEDs On load testing of release possible through TEST button (without tripping the breaker) Test kit (SRT) available for testing the releases Direct tripping of breakerreliable tripping with minimum time delay Conformance to EMI/EMC standards Type of Protection Pickup Current Setting Range Time Delay Long Time Short Time Instantaneous Ground Fault* Ir 0.5 to 1.0 times In Steps : 0., 0., 0., 0.70, 0., 0.80, 0.85, 0.9, 0.95, 1.00 to 10 times Ir Steps :, 3,, 5, 6, 7, 8, 9, 10 6 & In 0. to 0.6 times In Steps : 0., 0.3, 0., 0.5, sec at 6 time s Ir 0 to 0 ms Steps : 0,, 100, 1, 00,, 300, 0, 0, 0 ms 100 to 0 ms Steps : 100, 00, 300, 0 ms & OFF * Available in SR18G release only In 3 phase, wire system, Neutral CT is required for ground fault protection. 10
12 Protection releases Thermomagnetic Over Current Release Type DN1 DN1 is CToperated thermomagnetic release, which offers reliable protection against overload, short circuit and ground faults. Protection Overload Protection Continuous & individual phase adjustable dial settings from % to 100% of CT tap Inverse Time Characteristics Short Circuit Protection Two taps available to select operating threshold Ground Fault Protection Offered with auiliary earth fault release (0% to % In) Salient Features True RMS sensing 0 0 Ambient temperature compensated from 5 C to C Wide range of overload & short circuit settings possible with multitap CTs Each phase can be individually adjusted for overload & short circuit settings Fied minimum impulsion time of 5 ms on short circuit to prevent nuisance tripping due to transients Trip test facility available 11
13 Accessories Locks/Interlocks Type Data Lockable Trip Push utton (LTP) Mounted in place of normal trip push button. With this, AC can be locked in trip condition. For interlocking, LTPs are offered in the following combinations: different types of keys i.e. AA,, CC and DD suitable for incomers and 1 bus coupler schemes Combination of L, M, N, LM and MN locks, which are suitable for three incomer and two bus coupler schemes Combination of K, L, MN, KL, LM and MN locks, which are suitable for four incomer and three bus coupler schemes Combination of J, K, L, M, N, JK, KL, LM and MN locks, which are suitable for five incomer and four bus coupler schemes View of the Cradle Locking in Isolated Position (LIP) The facility of locking the AC in Isolated position is available in Drawout ACs. This is useful to achieve interlocking between Main & Standby source. Similar lock is available as LOCK IN ANY POSITION. Door Interlock Racking Inerlock Locking in Isolated Position Door Interlock This ensures: Unless the panel door is closed, breaker cannot be racked in or out Unless the breaker is in Isolated Position, it is not possible to open the panel door Racking Interlock This ensures that breaker cannot be racked in/out unless the AC is in tripped/open condition. Mechanical Interlock It is possible to provide Mechanical Interlock between two breakers of the same or different ratings in vertical or horizontal configurations. Mechanical interlock is available for ACs up to 00A. Mechanical interlocking for ACs in vertical configuration can be provided by links or by fleible cables. Same for horizontal configuration can be provided by fleible cables.
14 Accessories Signaling Type Data C1 Common indication of tripping due to overload, short circuit and ground faults. Provided by microswitch C1 fitted inside the AC Available as an option in all releases C Separate indication of tripping due to overload, short circuit and ground faults. For release type DN1, this is provided by microswitch C1 & C (C fitted inside release) Available through inbuilt fault indicators in SR18, SR18G, SR1i & SR71 releases AN1Annunciator Module Remote indication of tripping due to overload, short circuit and ground faults. Can be used with releases type SR18/SR18G/SR1i Individual fault indication provided by three separate LEDs for Long time faults Short time fault/instantaneous fault Ground fault one potential free contact rated 5A at 30V AC available for each type of fault Flush mounting on panel (HWD=9mm 6mm mm) Operating voltage: V AC/110V DC/0V DC (other Voltages available on request) C5 Indication for operation of shunt release or under voltage release. Provided by microswitch C5 fitted on the shunt release 13
15 Accessories Control Type Data Technical Data Shunt Release For remote tripping of the breaker Shunt release coil is short time rated and is disconnected from the circuit by an auiliary contact when the AC trips (Refer to wiring diagram) Low power consumption Two types available: EA for DC application EA1 for AC application Type of Release EA1 EA Nominal voltage Uc (V) Hz AC 15 AC V DC 8V DC 110 DC 0 DC Power consumption at pick up 800 VA 800 VA 3 W 5 W 5 W 30 W Note : Other voltages available on request Operation Limit 10130% Uc 130% Uc Undervoltage Release Two types available: Type MV With no intentional time delay Parameter Nominal voltage (Uc) Specification V & 15V: Hz 0V & 15V: Hz Notes: When undervoltage release is provided, the AC can be closed only when supply is available to the undervoltage release. Pick up (V) Drop OFF (V) Consumption (VA) 80% Uc 35% Uc Pick up 3 VA Hold on 10 VA Watt loss 6 W Auiliary Contacts Two combinations available: NO + NC 6 NO + 6 NC Electrical circuit Resistive Voltage (V) to 15 AC V AC Rated current (A) Nonresistive to 15 AC V AC # # L/R = 15ms with two contacts in series Operation Counter Operates mechanically Display total number of breaker operation cycles 1
16 Overall Dimensions Fied reakers For 630A to 0A /P for Metallic Components 36 min 36 min A min 100 min 9 3 min for Insulating Sheet 0 min 1 min to Remove Arc Chute 7 Door ezel Earthing Terminal HolesØ min D E F E D Ratings CN CS Dimensions (mm) A D E F Weight (kg.) Manual Electrical 630/800/A /10A /800/A P /10A P /0A /0A P For CNCS...E 0A000A 3 min Insulator +1.0 min 316 min min min Rating Type X Y Holes Ø 385 X X 0E E 10/ 000E Y Note : All Dimensions are in mm. 15
17 Overall Dimensions Fied reakers Terminal HolesØ HolesØ to 000E & 800///10 000/0 Terminal Connections Terminal for /10/000/0 ezel Fiing Plan for all Fied reakers 33 Hinge Hinge Terminal for 800/ HolesØ min min Door Cutout Door Drilling for ezel Fiing Plan ezel 16 Note: All dimensions are in mm.
18 Overall Dimensions Drawout reakers For 630A to 300A / /P, 300H1/00H for Metallic Components A ma min for Insulating Sheet 100 min 00 min Isolated Position 51 Test Position Service Position Door 6 7 ezel * M min ma min D E F E D 6.5 Earthing Terminal 5 *Terminal For 630/800/ /, /0 & *Terminal for /10/0 & 800/H *Terminal for for 300 *Terminal for 300H0/H1 & 00H0/H Ratings CN CS A Dimensions (mm) D E F 630/800/A / 000A /10A / 630/800/A / P 000A P /10A / P 000/0A 0/300A /0A 0/300A P P A 00A H0/H1 H0/H A 00A H0/H1 H0/H P P Note : All Dimensions are in mm. 17
19 Overall Dimensions Drawout reakers Flat Terminal Connections.5 slots Slots Slots C & H, /10 & C HolesØ1 6 HolesØ HolesØ & 000H H0/H & 00H0/H1.5 For 00C/6300C A ma 10 for Metallic Components 0 min for Insulating Sheet 100 min 00 min 51 Isolated Position Test Position Service Position 6 Door 7 ezel M min 18.9 ma min D E F E D 8 HolesØ Earthing Terminal Terminal Connections 00C/6300C Ratings Dimensions (mm) A D E F 00A C A C A C P A C P Note: All Dimensions are in mm.
20 Overall Dimensions Mounting Details For Horizontal Mounting of all Drawout reakers For 630A to 300A / /P 300 H0/H1, 00 H0/H /P HolesØ11 Ratings Type G (mm) 800A 10A 80.3 *G Front 630A 000A 800A 10A P A 000A P / 0A 000 / 0A 0 / 300A 0 / 300A P P For 00C/6300C /P HolesØ A 300A 00A 00A P P H0 / H1 H0 / H1 H0 / H H0 / H ezel Fiing Plan for all Drawout reakers HolesØ Hinge Hinge / 6300A C / 6300A P C 113 ase of Cradle min A 9 5 min Door Cutout Note: For 00C/6300C AC, A = 81.5 For other Drawout reakers A =
21 Overall Dimensions Terminals Horizontal Terminals Rear Side C 10 & 800/H 000C 0 & 000H HolesØ1 3 HolesØ1 HolesØ1 6 HolesØ V S W U.0 HolesØT O P N R X M Vertical Terminals Top Side View Rear View Ratings M N P Q R S T U V W X 800/A C /10A 800/A H A C A 000A H Note : 1) All Dimensions are in mm. ) Consult us for other Terminal Orientations.
22 Switchgear Training Centres Pune Lucknow Coonoor Train & Gain This concept underlies L&T s commitment to its customers and the Indian switchgear industry. To this end, L&T has set up Switchgear Training Centers equipped with a wide range of education facilities at Pune, Lucknow & Coonoor. Specially designed HandsOn training programs on the operation & maintenance of switchgear are conducted for engineers and technicians from different industry segments. The centers have stateoftheart training facilities, wellequipped workshops and testing systems. 1
23 Notes
24 Electrical Standard Products (ESP) ranch Offices: REGISTERED OFFICE AND HEAD OFFICE L&T House, allard Estate P. O. o 78 Mumbai Tel: 0656 Fa: Website: ELECTRICAL STANDARD PRODUCTS (ESP) 1, Sakar Comple I Opp. Gandhigram Rly. Station Ashram Road Ahmedabad Tel: Fa: / espahm@lnteg.com 38, Cubbon Road, P. O. o 98 angalore Tel: Fa: espblr@lnteg.com 131/1, Zone II Maharana Pratap Nagar hopal Tel: / 7 / 8 / 9 Fa: espbho@lnteg.com Plot No. 559, Annapurna Comple Lewis Road hubaneswar 1 01 Tel: 06713, Fa: espbbi@lnteg.com SCO 3, Sector 6D Madhya Marg, P. O. o 1 Chandigarh 1 06 Tel: , Fa: espchd@lnteg.com 10, Club House Road Chennai 0 00 Tel: / / 5 / 109 Fa: / 3 espmaa@lnteg.com 67, Appuswamy Road Post ag 7156 Opp. Nirmala College Coimbatore Tel: / 1 / 5 Fa: espcbe@lnteg.com L&T House, Group MIG5 Padmanabhpur Durg Tel: / 1 / 1 / 9 Fa: Khairasol, Degaul Avenue Durgapur 713 Tel: 55988, 55989, 5598 Fa: espdgp@lnteg.com Milanpur Road, amuni Maidan Guwahati Tel: Fa: espgau@lnteg.com II Floor, Vasantha Chambers , Fateh Maidan Road Hyderabad 000 Tel: Fa: esphyd@lnteg.com D, Prithvi Raj Road, CScheme Jaipur Tel: / 16 / 17 / 18 Fa: espjai@lnteg.com Akashdeep Plaza, nd Floor P. O. Golmuri Jamshedpur Jharkhand Tel: / 387 Fa: espjam@lnteg.com Skybright ldg; M. G. Road Ravipuram Junction, Ernakulam Kochi Tel: 0890 / / 5 / 7 Fa: espcok@lnteg.com 3, Shakespeare Sarani Kolkata Tel: / 3 / Fa: espccu@lnteg.com A8, Indira Nagar, Faizabad Road Lucknow Tel: / 5 / 6 Fa: esplko@lnteg.com No: 73, Karpaga Nagar, 8th Street K. Pudur Madurai 607 Tel: 05537, Fa: espmdu@lnteg.com EG North Wing OfficeLevel Gate 7, Powai Campus Mumbai 0 07 Tel: / 737 / 1156 Fa: espbom@lnteg.com #, Shivaji Nagar North Ambazari Road Nagpur 010 Tel: 070 / 3 Fa: 0700 / 30 espnag@lnteg.com 3, Shivaji Marg P. O. o 63 New Delhi Tel: / 5 / 6 Fa: espdel@lnteg.com L&T House P. O. o /1, Dhole Patil Road Pune Tel: Fa: , esppnq@lnteg.com 3rd Floor Vishwakarma Chambers Majura Gate, Ring Road Surat Tel: Fa: espsur@lnteg.com Radhadaya Comple Old Padra Road Near Charotar Society Vadodara Tel: / 1 / Fa: espbar@lnteg.com 8816, Dwarakanagar Visakhapatnam Tel: / 3 Fa: espviz@lnteg.com Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here. Electrical Standard Products Larsen & Toubro Limited Powai Campus, Mumbai 0 07 Customer Interaction Center (CIC) SNL / MTNL (toll free) : Reliance (toll free) : Tel : Fa : cic@lnteg.com Website : SP 37(R) 70111
Air Circuit Breakers
Air Circuit Breakers About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationMoulded case circuit brakers
Moulded case circuit brakers CONTENT Range 1 Protection Releases 2 Salient Features 5 Accessories 7 Widest Range 10 Time Current Characteristics 12 Overall Dimensions 14 SN4 SN3 SN2 SN1 3 RANGE SN1 Rated
More informationSave Lives, Protect Property with Intelligent Fire alarm systems from L&T
Save Lives, Protect Property with Intelligent Fire alarm systems from L&T The highest level of fire safety. About Us Larsen & Toubro is a technology-driven company that infuses engineering with imagination.
More information7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management
Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current
More informationWelcome to Hager Presentation
Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationDuctable Range of Air Conditioners
Ductable Range of Air Conditioners The world is witnessing growth at a breakneck speed. The upsurge in economic and social activities has led to rampant use of natural resources like water, minerals, energy,
More informationEARTH LEAKAGE RELAY. User Manual - Issue 1.0
Earth Leakage Relay www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters EARTH
More informationDue to its inherent characteristics, Screw Compressor has the highest volumetric efficiency, de-rating at higher temperature is negligible.
Blue Star, India s preferred airconditioning company has been providing expert cooling solutions for over six decades. It is with this expertise Blue Star brings to you a wide range of Air Cooled Screw
More informationHigh-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series
High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series NEW UNIQUE LCD CONTROLLER THE VOLTAS INTELLISYS RANGE Aero, Thermo and Tropico Series are High-performance Packaged & Ductable
More informationScrew Chillers. High on reliability. Low on operating cost.
Screw Chillers High on reliability. Low on operating cost. Blue Star, India s preferred airconditioning company has been providing expert cooling solutions for over six decades. It is with this expertise
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationIndex Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:
Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical
More informationLAWSON FINAL DISTRIBUTION PRODUCTS RANGE
FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company
More informationTable of Contents. Protective Relays
Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3
More informationAutomation Solution for
Automation Solution for Commercial and Residential Buildings Switchgear Training Center, Coonoor Powai Campus, Mumbai Switchgear Training Center, Lucknow Ahmednagar Campus Switchgear Training Center, Pune
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationDescription (Data Point Name) Unit Size
AC-PRO-II Communications Modbus Register Map Document Revision 2.0 Firmware v2.0 AC-PRO-II: Registers 7000 7019: Output Coils 7020 7099: Information 7107 7199: User settings (can be set using Modbus Communications)
More informationAnnunciator Unit SACO 16 D1. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open
More informationBE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.
BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,
More informationVAMP 120 & 121. Arc flash detection units. Product picture
Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationItem Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22
DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,
More informationDGC-1000 DIGITAL GENSET CONTROLLER
DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.
More informationModel VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch
Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional
More informationScroll Chillers Reliable and energy efficient chillers from the Experts _Scroll Chiller_BrochureV13.indd 1
Scroll Chillers Reliable and energy efficient chillers from the Experts 249200318_Scroll Chiller_BrochureV13.indd 1 25-04-2018 14:56:23 Blue Star, India s largest central air conditioning company, has
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationInvest in. Profitability
Invest in Training Enhance Profitability Training Calendar April 0 to March 06 TRAINING PROGRAMME DETAILS PROGRAM CODE TRAINING PROGRAM NO. OF DAYS PROGRAM CONTENTS USEFUL FOR INVESTMENT ` LT0 SELECTION
More informationOperation and use. Functions and characteristics
Operation and use Function Vigirex relays measure the earth-leakage current in an electrical installation via their associated toroids. Vigirex relays may be used for: b residual-current protection (RH10,
More information38-SDMS-04 REV. 0 SPECIFICATION FOR ANNUNCIATOR SYSTEMS FOR PRIMARY DISTRIBUTION SUBSTATION
38-SDMS-04 REV. 0 SPECIFICATION FOR ANNUNCIATOR SYSTEMS FOR PRIMARY DISTRIBUTION SUBSTATION This specification is property of SEC and subject to change or modification without any notice. TABLE OF CONTENTS
More informationModel VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass
Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:
More informationSENTINEL D - Fault Passage Monitoring
SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen
More informationVAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits
Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during
More information1.Application. 2.Main Technical Specifications B-10
NS Series Moulded Case Circuit Breaker 1.Application NS series moulded case circuit breaker is one of breaker which adopts international advanced design, manufacture technology to develop. The rated insulating
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationWITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE
WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE SBP1000-61 FTA1000 Full Voltage Starting Electric Fire Pump Controllers Product Description Description Firetrol FTA1000 Full Voltage Fire Pump Controllers
More informationVAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits
01 VAMP 120 & 121 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work
More informationZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement
Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationAnnunciator unit. Application
Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally
More informationAQ 100 Series. Arc Flash Protection System
AQ 100 Series Arc Flash Protection System THE CONSEQUENCES OF AN ARC FAULT IN HIGH VOLTAGE SWITCHGEAR THE CONSEQUENCES OF AN ARC FAULT IN OIL-FILLED SWITCHGEAR Arc Phenomena Arc Phenomena Arc fault - facts
More informationTough on Hard Water. Built for a longer life.
Tough on Hard Water. Built for a longer life. Electric Water Heaters Range 2016 HAVELLS today is known for high quality products & premium manufacturing infrastructure. This philosophy of providing its
More informationModels 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers
Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationTraceNet ECM Series Control System
TraceNet ECM Series Control System ECM Operating Guide Thermon Manufacturing Company TraceNet is a registered trademark of Thermon Manufacturing Company. ECM Operating Guide 2014, 2015 Thermon Manufacturing
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationLORAIN CSP DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More informationLORAIN CIP 4890/48120 DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationDeep Freezers, Bottle Coolers Milk Coolers and Visi Coolers
Deep Freezers, Bottle Coolers Milk Coolers and Visi Coolers Unmatched Cooling. Unmatched Freezing. From cooling to freezing. The best solutions from the Expert. Blue Star, being India s leading airconditioning
More informationProject: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch
Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationDPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description
DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges
More informationSpectron LSN (Life Safety Network) Suggested Specifications
1. General 1.1 Scope A Dual-Lite Spectron LSN (Life Safety Network) Series Inverter System shall be furnished to provide a reliable source of power, and shall operate during a utility line deficiency without
More informationSENTINEL A - Fault Passage Indicator
SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen
More informationisopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425
More informationSpeciality Cooling Products
Speciality Cooling Products For special refrigeration needs Blue Star, India s leading airconditioning and refrigeration company brings you speciality refrigeration products that cater to your special
More informationMultiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options
Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,
More informationLINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage
LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More information1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15
with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device
More informationCALTECH Pasadena, CA
CALTECH Pasadena, CA Power Distribution Unit 225kVA PDU with (3) 42ckt Panel Distribution ILL OF MATERIAL ITEM 3 Eaton Powerware - Power Distribution Unit (PDU) Qty (3) - 225kVA Power Distribution Unit
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre
More informationTECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2
FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in
More informationMODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White
Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress
More informationFamily of motor protection
Family of motor protection & control relays Totally protect all induction motors Reduce motor downtime SOLCON MPC 2000 Incorporationg similar motor protection features to the MPR 2000 and 45 programmable
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationwww. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application
Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator
More informationModel 7700 Pump Director Valve and Pump Motor Interface Controller
Model 7700 Pump Director Valve and Pump Motor Interface Controller A Century of Experience VAG GA Industries valves are known for long term reliability in the most demanding water and wastewater applications.
More informationLow Temperature Zirconia Oxygen Analyzer
Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationLINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry
LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional
More informationisopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv
More informationHTC-915-CONT. Heat-Trace Control system
Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring
More informationFCR 05, FCR 07. Power factor correction controller. User and service manual
FCR 05, FCR 07 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction
More information7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. 7PG17 XR105, XR106 and XR107, XR205 and XR206 Interposing
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationRoom thermostats with LCD for wall mounting
s 3 181 RDG100 / RDG110 RDG140 / RDG100 RDG100/H Room thermostats with LCD for wall mounting for fan coil unit applications for universal applications for use with compressors in dx type equipment RDG1
More informationCeiec Electric Technology
PMC-53 Series Intelligent Multifunction Meter User Manual Version: V5.2A 02/07/2012 Ceiec Electric Technology This manual may not be reproduced in whole or in part by any means without the express written
More informationMODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points
Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment
More informationT8000 Series T8600 MODBUS Touch Screen Thermostat
T8 Series T86 MODUS Touch Screen Thermostat T86 MODUS Series Touch Screen Thermostat Application T86 JS/R Touch screen thermostats are designed to control heating, cooling, or air conditioning unit in
More information7SG17-Rho 3 Multifunction Protection Relays Answers for energy
Reyrolle Protection Devices 7SG17-Rho 3 Multifunction Protection Relays Answers for energy 7SG17 Rho3 Contents Contents Technical Manual Chapters 1. Description of Operation 2. Performance Specification
More informationPRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING
PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial
More informationOPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)
OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N) MRM PROCOM Pvt Ltd An ISO-9001-2008 certified organization Works: Plot No. 20-21, Sector 59, Phase II, Faridabad, Haryana -121004 Ph: 0129-4700400
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits
More informationLa Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The
More informationSeries G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description
September 2007 NG-Frame 400 s NG-Frame Technical Data and Specifications Table -60. UL 489/IEC 60947-2 Interrupting Capacity s Circuit Breaker Type Interrupting Capacity (ka Symmetrical s) Volts ac (50/60
More informationDPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-
DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature
More information