EMERGENCY LIGHT SERIES

Size: px
Start display at page:

Download "EMERGENCY LIGHT SERIES"

Transcription

1 ASENWARE EMERGENCY LIGHT SERIES 1 / 38 EMERGENCY LIGHT SERIES 1 About ASENWARE was set up at 2005 in UK. After over 10 years very fast developing, we keep the high investment for R&D and international certificates, now ASENWARE became a famous brand in Fire system. Our products include Fire Alarm and Fire suppression System, Emergency Light, CCTV cameras and DDC/HVAC system. For more information about us, please sales08@asenware.com 2 Emergency Light introduction Emergency Light is a vital and effective life safety tool, providing reassurance and guidance to people at critical times when they need escape quickly and safely from a building. The main reason for installing an emergency lighting system is to enable the building to meet fire safety legislation in a way that is visually acceptable and meets the user s needs for ease of operation and maintenance. Consequently it is important to establish all the relevant legal requirements for emergency lighting and fire alarm systems before commencing the design these should ideally be agreed between the system designer, user, fire authority, building control officer and system installer. 3 ASENWARE Emergency Light Series 3.1 AW-EL101: General Emergency Light,

2 ASENWARE EMERGENCY LIGHT SERIES 2 / 38 LED Lamp Emergency Light: Fluorescent T5 Emergency Light: The General Emergency Light is used for high profile commercial and industrial building, new design flow lined fire proof plastic shell and High transparent top cover, available with multi bar LED or fluorescent T5/8W tube,,available with 1h,1.5h,2h,3h duration time, available with self-test function, with battery protection,easy installation. 3.2 AW-EL200 Twin Spot Emergency Luminaires

3 ASENWARE EMERGENCY LIGHT SERIES 3 / 38 Normal Type: With Switch Type: With Switch and Exit Sign Type:

4 ASENWARE EMERGENCY LIGHT SERIES 4 / 38 The Twin Spot Emergency luminaires are designed for different country, with metal shell, LED light, nickel-cadmium or lead-acid battery, with battery protection, available with self-test function, available with single lamp control, available with exit direction control. 3.3 AW-EL300 Suspended LED Acrylic Exit Signs LED Acrylic Exit Sign on light 3.4 AW-EL400 Suspended Exit Sign Boards Emergency Exit Sign Board

5 ASENWARE EMERGENCY LIGHT SERIES 5 / 38 4 AW-EL101: General Emergency Light LED Lamp Emergency Light: Fluorescent T5 Emergency Light: 4.1 General technical parameters Item Supply work voltage range Operation mode Lamp Battery Battery protection Charging time Self-test Control mode Material Value 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Non-maintained LED 16pcs/bar, 1/2/3/5 bar Or Fluorescent T5/8W tube 1/2/3 Nickel-cadmium Or Lead-acid Yes <24 hours Available Emergency only Or On/Off switch +Emergency Fire proof plastic

6 ASENWARE EMERGENCY LIGHT SERIES 6 / 38 Installation Wall mounted Protection level IP30 Product size 345x110x80mm Packing Carton Carton quantity 10 Carton size 460*380*280mm Carton weight Approx 13kg with 10pcs/carton Work temperature -10~55 Work humidity 95% Customization Light source, Battery, Duration Time, Package, Control mode Standards ISO9000 CE BS IEC Pictures LED Lamp Emergency Light Type Front side view Left side view Top view Back side view Fluorescent Lamp Emergency Light Type

7 ASENWARE EMERGENCY LIGHT SERIES 7 / 38 Front side view Left side view Top view Back side view 4.3 Installation guide

8 ASENWARE EMERGENCY LIGHT SERIES 8 / 38 Step1: Open the emergency light cover Step 2: Follow the instruction to connect the battery and PCB board with wires Step 4: Install the emergency light on the wall Step 3: Tack four plastic studs on the ceiling Step 6: Finished Step 5: Cover the emergency light shell 4.4 Order information

9 ASENWARE EMERGENCY LIGHT SERIES 9 / 38 Model No. ON Self Duration Lamp Lamp Battery Battery / - Luminance time type qty type capacity OFF Test (min) AW-EL101LA16NC1AE No A Normal LED NC 3.6V/0.15Ah AW-EL101LA16NC2AE No A Normal LED NC 3.6V/0.2Ah AW-EL101LA16NC3AE No A Normal LED NC 3.6V/0.3Ah AW-EL101LA16NC4AE No A Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC1AE No A Normal LED NC 3.6V/0.2Ah AW-EL101LA32NC2AE No A Normal LED NC 3.6V/0.3Ah AW-EL101LA32NC3AE No A Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC4AE No A Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC1AE No A Normal LED NC 3.6V/0.3Ah AW-EL101LA48NC2AE No A Normal LED NC 3.6V/0.4Ah AW-EL101LA48NC3AE No A Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC4AE No A Normal LED NC 3.6V/0.8Ah AW-EL101LA80NC1AE No A Normal LED NC 3.6V/0.5Ah AW-EL101LA80NC2AE No A Normal LED NC 3.6V/0.7Ah AW-EL101LA80NC3AE No A Normal LED NC 3.6V/0.9Ah AW-EL101LA80NC4AE No A Normal LED NC 3.6V/1.3Ah AW-EL101LB16NC1AE No A Supper LED NC 3.6V/0.3Ah AW-EL101LB16NC2AE No A Supper LED NC 3.6V/0.5Ah AW-EL101LB16NC3AE No A Supper LED NC 3.6V/0.6Ah AW-EL101LB16NC4AE No A Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC1AE No A Supper LED NC 3.6V/0.5Ah AW-EL101LB32NC2AE No A Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC3AE No A Supper LED NC 3.6V/0.9Ah AW-EL101LB32NC4AE No A Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC1AE No A Supper LED NC 3.6V/0.7Ah AW-EL101LB48NC2AE No A Supper LED NC 3.6V/0.9Ah AW-EL101LB48NC3AE No A Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC4AE No A Supper LED NC 3.6V/1.8Ah AW-EL101LB80NC1AE No A Supper LED NC 3.6V/1.0Ah AW-EL101LB80NC2AE No A Supper LED NC 3.6V/1.5Ah AW-EL101LB80NC3AE No A Supper LED NC 3.6V/1.8Ah AW-EL101LB80LC4AE No A Supper LED NC 6.0V/2.8Ah AW-EL101LA16NC1ME No M Normal LED NC 3.6V/0.15Ah AW-EL101LA16NC2ME No M Normal LED NC 3.6V/0.2Ah AW-EL101LA16NC3ME No M Normal LED NC 3.6V/0.3Ah AW-EL101LA16NC4ME No M Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC1ME No M Normal LED NC 3.6V/0.2Ah AW-EL101LA32NC2ME No M Normal LED NC 3.6V/0.3Ah AW-EL101LA32NC3ME No M Normal LED NC 3.6V/0.4Ah

10 ASENWARE EMERGENCY LIGHT SERIES 10 / 38 AW-EL101LA32NC4ME No M Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC1ME No M Normal LED NC 3.6V/0.3Ah AW-EL101LA48NC2ME No M Normal LED NC 3.6V/0.4Ah AW-EL101LA48NC3ME No M Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC4ME No M Normal LED NC 3.6V/0.8Ah AW-EL101LA80NC1ME No M Normal LED NC 3.6V/0.5Ah AW-EL101LA80NC2ME No M Normal LED NC 3.6V/0.7Ah AW-EL101LA80NC3ME No M Normal LED NC 3.6V/0.9Ah AW-EL101LA80NC4ME No M Normal LED NC 3.6V/1.3Ah AW-EL101LB16NC1ME No M Supper LED NC 3.6V/0.3Ah AW-EL101LB16NC2ME No M Supper LED NC 3.6V/0.5Ah AW-EL101LB16NC3ME No M Supper LED NC 3.6V/0.6Ah AW-EL101LB16NC4ME No M Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC1ME No M Supper LED NC 3.6V/0.5Ah AW-EL101LB32NC2ME No M Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC3ME No M Supper LED NC 3.6V/0.9Ah AW-EL101LB32NC4ME No M Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC1ME No M Supper LED NC 3.6V/0.7Ah AW-EL101LB48NC2ME No M Supper LED NC 3.6V/0.9Ah AW-EL101LB48NC3ME No M Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC4ME No M Supper LED NC 3.6V/1.8Ah AW-EL101LB80NC1ME No M Supper LED NC 3.6V/1.0Ah AW-EL101LB80NC2ME No M Supper LED NC 3.6V/1.5Ah AW-EL101LB80NC3ME No M Supper LED NC 3.6V/1.8Ah AW-EL101LB80LC4ME No M Supper LED LC 6.0V/2.8Ah AW-EL101TA01NC1AE No A Normal FL T NC 3.6V/0.8Ah AW-EL101TA01NC2AE No A Normal FL T NC 3.6V/1.1Ah AW-EL101TA01NC3AE No A Normal FL T NC 3.6V/1.5Ah AW-EL101TA01NC4AE No A Normal FL T NC 3.6V/2.0Ah AW-EL101TA02NC1AE No A Normal FL T LC 6.0V/1.0Ah AW-EL101TA02LC2AE No A Normal FL T LC 6.0V/1.5Ah AW-EL101TA02LC3AE No A Normal FL T LC 6.0V/2.0Ah AW-EL101TA02LC4AE No A Normal FL T LC 6.0V/3.0Ah AW-EL101TA03LC1AE No A Normal FL T LC 6.0V/1.5Ah AW-EL101TA03LC2AE No A Normal FL T LC 6.0V/2.2Ah AW-EL101TA03LC3AE No A Normal FL T LC 6.0V/3.0Ah AW-EL101TA03LC4AE No A Normal FL T LC 6.0V/4.5Ah AW-EL101LA16NC1AO Yes A Normal LED NC 3.6V/0.15Ah AW-EL101LA16NC2AO Yes A Normal LED NC 3.6V/0.2Ah AW-EL101LA16NC3AO Yes A Normal LED NC 3.6V/0.3Ah AW-EL101LA16NC4AO Yes A Normal LED NC 3.6V/0.4Ah

11 ASENWARE EMERGENCY LIGHT SERIES 11 / 38 AW-EL101LA32NC1AO Yes A Normal LED NC 3.6V/0.2Ah AW-EL101LA32NC2AO Yes A Normal LED NC 3.6V/0.3Ah AW-EL101LA32NC3AO Yes A Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC4AO Yes A Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC1AO Yes A Normal LED NC 3.6V/0.3Ah AW-EL101LA48NC2AO Yes A Normal LED NC 3.6V/0.4Ah AW-EL101LA48NC3AO Yes A Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC4AO Yes A Normal LED NC 3.6V/0.8Ah AW-EL101LA80NC1AO Yes A Normal LED NC 3.6V/0.5Ah AW-EL101LA80NC2AO Yes A Normal LED NC 3.6V/0.7Ah AW-EL101LA80NC3AO Yes A Normal LED NC 3.6V/0.9Ah AW-EL101LA80NC4AO Yes A Normal LED NC 3.6V/1.3Ah AW-EL101LB16NC1AO Yes A Supper LED NC 3.6V/0.3Ah AW-EL101LB16NC2AO Yes A Supper LED NC 3.6V/0.5Ah AW-EL101LB16NC3AO Yes A Supper LED NC 3.6V/0.6Ah AW-EL101LB16NC4AO Yes A Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC1AO Yes A Supper LED NC 3.6V/0.5Ah AW-EL101LB32NC2AO Yes A Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC3AO Yes A Supper LED NC 3.6V/0.9Ah AW-EL101LB32NC4AO Yes A Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC1AO Yes A Supper LED NC 3.6V/0.7Ah AW-EL101LB48NC2AO Yes A Supper LED NC 3.6V/0.9Ah AW-EL101LB48NC3AO Yes A Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC4AO Yes A Supper LED NC 3.6V/1.8Ah AW-EL101LB80NC1AO Yes A Supper LED NC 3.6V/1.0Ah AW-EL101LB80NC2AO Yes A Supper LED NC 3.6V/1.5Ah AW-EL101LB80NC3AO Yes A Supper LED NC 3.6V/1.8Ah AW-EL101LB80LC4AO Yes A Supper LED LC 6.0V/2.8Ah AW-EL101LA16NC1MO Yes M Normal LED NC 3.6V/0.15Ah AW-EL101LA16NC2MO Yes M Normal LED NC 3.6V/0.2Ah AW-EL101LA16NC3MO Yes M Normal LED NC 3.6V/0.3Ah AW-EL101LA16NC4MO Yes M Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC1MO Yes M Normal LED NC 3.6V/0.2Ah AW-EL101LA32NC2MO Yes M Normal LED NC 3.6V/0.3Ah AW-EL101LA32NC3MO Yes M Normal LED NC 3.6V/0.4Ah AW-EL101LA32NC4MO Yes M Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC1MO Yes M Normal LED NC 3.6V/0.3Ah AW-EL101LA48NC2MO Yes M Normal LED NC 3.6V/0.4Ah AW-EL101LA48NC3MO Yes M Normal LED NC 3.6V/0.6Ah AW-EL101LA48NC4MO Yes M Normal LED NC 3.6V/0.8Ah AW-EL101LA80NC1MO Yes M Normal LED NC 3.6V/0.5Ah AW-EL101LA80NC2MO Yes M Normal LED NC 3.6V/0.7Ah

12 ASENWARE EMERGENCY LIGHT SERIES 12 / 38 AW-EL101LA80NC3MO Yes M Normal LED NC 3.6V/0.9Ah AW-EL101LA80NC4MO Yes M Normal LED NC 3.6V/1.3Ah AW-EL101LB16NC1MO Yes M Supper LED NC 3.6V/0.3Ah AW-EL101LB16NC2MO Yes M Supper LED NC 3.6V/0.5Ah AW-EL101LB16NC3MO Yes M Supper LED NC 3.6V/0.6Ah AW-EL101LB16NC4MO Yes M Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC1MO Yes M Supper LED NC 3.6V/0.5Ah AW-EL101LB32NC2MO Yes M Supper LED NC 3.6V/0.7Ah AW-EL101LB32NC3MO Yes M Supper LED NC 3.6V/0.9Ah AW-EL101LB32NC4MO Yes M Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC1MO Yes M Supper LED NC 3.6V/0.7Ah AW-EL101LB48NC2MO Yes M Supper LED NC 3.6V/0.9Ah AW-EL101LB48NC3MO Yes M Supper LED NC 3.6V/1.2Ah AW-EL101LB48NC4MO Yes M Supper LED NC 3.6V/1.8Ah AW-EL101LB80NC1MO Yes M Supper LED NC 3.6V/1.0Ah AW-EL101LB80NC2MO Yes M Supper LED NC 3.6V/1.5Ah AW-EL101LB80NC3MO Yes M Supper LED NC 3.6V/1.8Ah AW-EL101LB80LC4MO Yes M Supper LED LC 6.0V/2.8Ah AW-EL101TA01NC1AO Yes A Normal FL T NC 3.6V/0.8Ah AW-EL101TA01NC2AO Yes A Normal FL T NC 3.6V/1.1Ah AW-EL101TA01NC3AO Yes A Normal FL T NC 3.6V/1.5Ah AW-EL101TA01NC4AO Yes A Normal FL T NC 3.6V/2.0Ah AW-EL101TA02NC1AO Yes A Normal FL T LC 6.0V/1.0Ah AW-EL101TA02LC2AO Yes A Normal FL T LC 6.0V/1.5Ah AW-EL101TA02LC3AO Yes A Normal FL T LC 6.0V/2.0Ah AW-EL101TA02LC4AO Yes A Normal FL T LC 6.0V/3.0Ah AW-EL101TA03LC1AO Yes A Normal FL T LC 6.0V/1.5Ah AW-EL101TA03LC2AO Yes A Normal FL T LC 6.0V/2.2Ah AW-EL101TA03LC3AO Yes A Normal FL T LC 6.0V/3.0Ah AW-EL101TA03LC4AO Yes A Normal FL T LC 6.0V/4.5Ah 4.5 Note Self-test: A=Disable, M=Enable Lamp type: LED=2835LED, FL T5= Fluorescent T5/8W tube Battery type: NC=Nickel-cadmium, LC=Lead acid Supply Default Model No. is AW-EL101LA48NC4AE, 48pcs LED, 180min duration time, 220VAC Different signs of exit adhesive sticker:

13 ASENWARE EMERGENCY LIGHT SERIES 13 / 38 The surface exit indicator sticker is optional. 5 AW-EL200 Twin Spot Emergency Luminaires 5.1 AW-EL201

14 ASENWARE EMERGENCY LIGHT SERIES 14 / 38 AW-EL200 is an economic Twin Spot Emergency Luminaires General technical parameters Item Value Supply work voltage range 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Operation mode Non-maintained Lamp LED 1pcs/ spot Twin spot Battery Nickel-cadmium Or Lead-acid Battery protection Yes Charging time <24 hours Self-test Available Control mode Emergency only Or On/Off switch +Emergency Material Metal Installation Wall mounted Protection level IP30 Product size 280mm*65mm*265mm Packing Carton Carton quantity 10 Carton size 575mm*355mm*275mm Carton weight Approx 8.5kg with 10pcs/carton

15 ASENWARE EMERGENCY LIGHT SERIES 15 / 38 Work temperature -10~55 Work humidity 95% Customization Light source, Battery, Duration Time, Package, Control mode ISO9000 Standards CE BS IEC Pictures Front side view Left side view Right side view Back side view

16 ASENWARE EMERGENCY LIGHT SERIES 16 / Installation guide

17 ASENWARE EMERGENCY LIGHT SERIES 17 / 38 Step1: Prepare 2 sets expansion screw PA3.5*15mm. Step2: Drill 2 holes apart of 211mm on the suitable place of the wall, then insert 2 sets plastic bar of the expansion screws. 211mm A B B Step4: Put the emergency light on the 2 screws, via the 2 slotted holes of the back side. Step3: Install the 2 screws into the plastic bars, but keep the head of the screw over about 3-5mm of the wall. Step5: After the installation, plug into the power socket. Then the emergency light can work normally Order information Model No. ON/ OFF Self - Test Luminance Lamp type Lamp qty Duration Time (min) Battery type Battery capacity

18 ASENWARE EMERGENCY LIGHT SERIES 18 / 38 AW- EL201LA02NC1AE No A Normal LED 2 60 NC 1.2V/0.3Ah AW- EL201LA02NC2AE No A Normal LED 2 90 NC 1.2V/0.45Ah AW- EL201LA02NC3AE No A Normal LED NC 1.2V/0.6Ah AW- EL201LA02NC4AE No A Normal LED NC 1.2V/0.8Ah AW- EL201LA02NC1ME No M Normal LED 2 60 NC 1.2V/0.6Ah AW- EL201LA02NC2ME No M Normal LED 2 90 NC 1.2V/0.8Ah AW- EL201LA02NC3ME No M Normal LED NC 1.2V/1.2Ah AW- EL201LA02NC4ME No M Normal LED NC 1.2V/1.6Ah Note Self-test: A=Disable, M=Enable Lamp type: LED=2835LED, FL T5= Fluorescent T5/8W tube Battery type: NC=Nickel-cadmium, LC=Lead acid Supply Default Model No. is AW-EL201LA02NC4AE, 2pcs LED, 180min duration time,220vac. 5.2 AW-EL202

19 ASENWARE EMERGENCY LIGHT SERIES 19 / 38 Twin Spot Emergency Luminaires with switch AW-EL202 is a Twin Spot emergency luminaires with 2 switches, each lamp spot can be switched ON/OFF. Each lamp has 6 LEDs to supply high luminance General technical parameters Item Supply work voltage range Operation mode Lamp Lamp control Battery Battery protection Charging time Self-test Control mode Material Installation Protection level Product size Value 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Non-maintained LED 6pcs/ spot Twin spot Left switch+ right switch Nickel-cadmium Or Lead-acid Yes <24 hours Available Emergency only Or On/Off switch +Emergency Metal Wall mounted IP30 295mm*105mm*295mm

20 ASENWARE EMERGENCY LIGHT SERIES 20 / 38 Packing Carton Carton quantity 10 Carton size 595mm*530mm*300mm Carton weight Approx 16kg with 10pcs/carton Work temperature -10~55 Work humidity 95% Customization Light source, Battery, Duration Time, Package, Control mode ISO9000 Standards CE BS IEC Pictures Front side view Left side view Right side view Back side view

21 ASENWARE EMERGENCY LIGHT SERIES 21 / Installation guide Step1: Prepare 2 sets expansion screw PA3.5*15mm. Step2: Drill 2 holes apart of 195mm on the suitable place of the wall, then insert the 2 sets plastic bar of the expansion screws. A B Step4: Put the emergency light on the 2 screws, via the 2 slotted holes of the back side. Step3: Install the 2 screws into the plastic bars, but keep the head of the screw over about 3-5mm of the wall. Step5: After the installation, plug into the power socket. Then the emergency light can work normally.

22 ASENWARE EMERGENCY LIGHT SERIES 22 / Order information Model No. ON/ OFF Self - Test Luminance Lamp type Lamp qty Duration Time (min) Battery type Battery capacity AW- EL202LA12NC1AE Yes M Normal LED LC 6.0V/0.4Ah AW- EL202LA12NC2AE Yes M Normal LED LC 6.0V/0.6Ah AW- EL202LA12NC3AE Yes M Normal LED LC 6.0V/0.8Ah AW- EL202LA12NC4AE Yes M Normal LED LC 6.0V/1.2Ah Note: Self-test: A=Disable, M=Enable Lamp type: LED=2835LED, FL T5= Fluorescent T5/8W tube Battery type: NC=Nickel-cadmium, LC=Lead acid Supply Default Model No. is AW-EL202LA12NC4AE, 12pcs LED, 180min duration time,220vac. Other model No. are customized. 5.3 AW-EL203

23 ASENWARE EMERGENCY LIGHT SERIES 23 / 38 AW-EL203 is a Twin Spot emergency luminaires with 4 switches, each lamp spot can be switched ON/OFF, Each lamp has 6 LEDs to supply high luminance. And there are 2 EXIT indicators: left side and right side, each indication has a LED and can be switched ON/OFF General technical parameters Item Supply work voltage range Operation mode Lamp Lamp control Exit direction indicator control Battery Battery protection Charging time Self-test Control mode Material Installation Protection level Product size Value 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Non-maintained LED 6pcs/ spot Twin spot Left switch+ right switch Left switch+ right switch Nickel-cadmium Or Lead-acid Yes <24 hours Available Emergency only Or On/Off switch +Emergency Metal Wall mounted IP30 295mm*105mm*295mm

24 ASENWARE EMERGENCY LIGHT SERIES 24 / 38 Packing Carton Carton quantity 10 Carton size 595mm*530mm*300mm Carton weight Approx 16kg with 10pcs/carton Work temperature -10~55 Work humidity 95% Customization Light source, Battery, Duration Time, Package, Control mode ISO9000 Standards CE BS IEC Pictures Front side view

25 ASENWARE EMERGENCY LIGHT SERIES 25 / 38 Left side view Right side view Back side view Installation guide Step1: Prepare 2 sets expansion screw PA3.5*15mm Step2: Drill 2 holes apart of 195mm on the suitable place of the wall, then insert the 2 sets plastic bar of the expansion screws. Step4: Put the emergency light on the 2 screws, via the 2 slotted holes of the back side. Step3: Install the 2 screws into the plastic bars, but keep the head of the screw over about 3-5mm of the wall.

26 ASENWARE EMERGENCY LIGHT SERIES 26 / 38 6 AW-EL300 Suspended LED Acrylic Exit Signs AW-EL300 is suspended installation type with 6-8 LED light and transparent acrylic board. It is easy to be carved to different design, to be suitable different country language, different exit direction, even different photo like coffee, toilet, casher and so on. It is nice looking, always used in office building, shopping mall, coffee shop, restaurant, hotel, hospital and so on General technical parameters Item Supply work voltage range Operation mode Lamp Value 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Non-maintained LED 6pcs

27 ASENWARE EMERGENCY LIGHT SERIES 27 / 38 Sight distance 20m Material Aluminum+Transparent acrylic board Exit direction made Carved Battery Nickel-cadmium Battery protection Yes Charging time <24 hours Duration time 180 minutes Work mode Constant light Installation Suspended Protection level IP30 Product size 340*180*25mm Packing Carton Carton quantity 10 Carton size 380*205*270mm Carton weight Approx 14kg with 10pcs/carton Work temperature -10~55 Work humidity 95% Customization Different design ISO9000 Standards CE BS IEC Available designs

28 ASENWARE EMERGENCY LIGHT SERIES 28 / 38 If big quantity, the sign can be customization. 6.2 AW-EL400 Suspended Exit Sign Boards AW-EL400 is an economic and conventional EXIT sign board, can be made different design according to the different country s fire standard General technical parameters Item Value Supply work voltage range 110V-127VAC 50/60Hz; Or 220V-240VAC 50/60Hz Operation mode Non-maintained Lamp LED 4pcs Sight distance 20m Material Aluminum + glass Exit direction made Screen print Battery Nickel-cadmium Battery protection Yes Charging time <24 hours Duration time 120 minutes Work mode Constant light Installation Suspended Protection level IP30 Product size 360*145*25mm Packing Carton Carton quantity 10 Carton size 375*160*270mm Carton weight Approx 10kg with 10pcs/carton Work temperature -10~55 Work humidity 95%

29 ASENWARE EMERGENCY LIGHT SERIES 29 / 38 Customization Standards Different design ISO9000 CE BS IEC Available designs (If big quantity, the sign can be customization.) 7 Locate luminaires at mandatory points of emphasis Initial design is conducted by situating luminaires to reveal specific hazards and highlight safety equipment and signs, in addition to providing illumination to assist safe travel along the escape route. This should be performed regardless of whether it is an emergency escape route or an open (anti-panic) area.

30 ASENWARE EMERGENCY LIGHT SERIES 30 / 38

31 ASENWARE EMERGENCY LIGHT SERIES 31 / 38 Note - the term near means within 2 meters measured horizontally. 8 Ensure that exit signs are of correct format and size Signs which are provided at all exits intended to be used in an emergency and along escape routes shall be illuminated to indicate the route of escape to a point of safety. Where direct sight of an emergency exit is not possible, an illuminated directional sign (or series of signs) shall be provided to assist progression towards the emergency exit. Maximum viewing distances

32 ASENWARE EMERGENCY LIGHT SERIES 32 / 38 9 Illumination requirements The sign must conform to the colours of ISO 3864, which defines that exit and first aid signs must be white with green as the contrast colour. The ratio of luminance of the white colour to the green colour must be between 5:1 and 15:1. The minimum luminance of any 10mm patch area on the sign must be greater than 2cd/m 2 and the ratio of maximum to minimum luminance shall be less than 10:1 for either colour.

33 ASENWARE EMERGENCY LIGHT SERIES 33 / Locate luminaires at the following essential areas in the buildings a) Lift cars - although only in exceptional circumstances will they be part of the escape route, do present a problem in the public may be trapped in them in the event Of a supply failure. b) Toilets - all toilets for the disabled and facilities exceeding 8m 2 floor area or without borrowed lights. c) Escalators - to enable users to get off them safely.

34 ASENWARE EMERGENCY LIGHT SERIES 34 / 38 e) Covered car parks - the normal pedestrian routes should be provided with non-maintained luminaires of at least 1 hour duration. d) Motor generator, control or panel room - require battery supplied emergency lighting to assist any maintenance or operating personnel in the event of failure.

35 ASENWARE EMERGENCY LIGHT SERIES 35 / Escape route lighting it is essential to provide any additional luminaires to ensure that minimum illuminance levels are met to enable the routes to be used safely. In addition, every compartment on the escape route must have at least two luminaries, to provide some light in the event of luminaires failure. A uniformity ratio of 40:1 maximum to minimum must not be exceeded. This illuminance must be provided must be provided for the full duration and life of the system. 50% of the illuminance must be available within 5 seconds and the full value within 60 seconds of supply failure. Add additional luminaire to achieve 1 lux minimum. 12 Open (anti-panic) core areas Areas larger than 60m 2, open areas with an escape route passing through them, or hazards identified by the building risk assessment all require emergency lighting. The

36 ASENWARE EMERGENCY LIGHT SERIES 36 / 38 current standard is easy to design for and to verify, promoting systems that provide good uniformity rather than ones that use a few large output luminaires. 13 High risk task area lighting Areas of high physical risk, or the control rooms of dangerous plant and production lines, need emergency lighting to enable them to be shut down safely. BS5266 Part 1: 1999 defines that emergency lighting should provide 10% of the normal lighting level at the hazard, with a minimum of 15 Lux. (In practice this minimum is unlikely ever to be a problem, as it would only be valid if the risk area had a normal illumination level less than 150 lux).

37 ASENWARE EMERGENCY LIGHT SERIES 37 / Control Non-maintained luminaires must be activated by failure of supply to the normal lighting. They must therefore be connected an unswitched live taken from the local normal lighting final circuit. 15 Testing and log book Discussions with the user or system designer should identify: - The caliber and reliability of staff available to do the testing - The level of difficulty in performing the test - If discharge tests need to be done outside normal working hours, or phased so only alternate luminaires are tested in buildings that are permanently occupied.

38 ASENWARE EMERGENCY LIGHT SERIES 38 / 38 The testing requirements in the code of practice are: Function test All emergency luminaires should be tested be breaking the supply to them and checking that they operate satisfactorily. The supply must then be restored and the charging indicators must be seen to be operating correctly. This test must be performed at least once once per month and the results logged. Discharge test The luminaires must be tested for their full rated duration period and checked for satisfactory operation. The supply must then be restored and the charging indicators rechecked. This test must be performed at least annually and the results logged. 16 Manual testing If manual testing is utilized, the following points should be considered: - Is a single switch to be used? Unless the whole building is to be switched off, a separate switch should be used for each final circuit. As the feed to non-maintained circuits must be taken from the switch this will probably mean that the building will have to be walked around twice, once to check the luminaires and once to check that they are recharging. - Are luminaires to be individually switched? In practice, only a single walk around the building will be needed. However, the test switches could spoil the decor of the building and they must be of a type that is tamper proof. After the tests, the performance of the luminaires must be logged. ************************************************************************************************ Thanks for reading ASENWAER Emergency Light Series Catalog and User Manual, we supply the perfect quality products and lower price, and we supply 7*24 online technology support for before and after sales, each product has 2 years warranty, and if the problem is because of our product quality, we supply free replacement. Hope to cooperate with you!.

Technical reference Reference & design

Technical reference Reference & design The requirement for emergency lighting originates from the Fire Precautions Act 1971 and was further enforced by the Fire Precautions (Workplace) Regulations 1997 (Amended 1999). The Regulatory Reform

More information

Dublin airport - Dublin, Ireland

Dublin airport - Dublin, Ireland Dublin airport - Dublin, Ireland 604 Route LED 607 Route LED II 608 SYL Safe EMERGENCY 601 Emergency 80 Hammersmith Road - London, England Control Gear: Electronic Integral Sensor: Not applicable Emergency:

More information

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager What is emergency lighting? Legislation and standards Emergency lighting design Emergency lighting testing requirements

More information

Emergency Lighting Design

Emergency Lighting Design SECTION 3: 9: page 1 Section 9: Emergency Lighting Design SECTION 9: page 3 Introduction When the electricity supply fails and the lights go out, it is essential that emergency lighting is automatically

More information

A Guide To BS Understanding the selection, spacing & siting of detectors

A Guide To BS Understanding the selection, spacing & siting of detectors World Class Leaders in Fire Detection Since 1918 A Guide To BS5266-12016 Understanding the selection, spacing & siting of detectors Extra Low Voltage LED Technology Low Maintenance Intelligent Simple Installation

More information

New Fire Safety Order

New Fire Safety Order Voltimum Technical seminar New Fire Safety Order Implications for the Emergency Lighting Systems Presented by Chris Watts Cooper Lighting and Security Chairman of - British Standards CPL 34/9 Code of Practice

More information

Emergency Lighting User's Guide

Emergency Lighting User's Guide Emergency Lighting User's Guide Emergency Lighting System Emergency Lighting System Emergency lighting systems are the systems that become automatically active and provide adequate lighting when the main

More information

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007) Safety Lighting Prof. Grega Bizjak, PhD Laboratory of Lighting and Photometry Faculty of Electrical Engineering University of Ljubljana Safe also without electricity Since it is practically impossible

More information

WZ-T8-W18 T8 LED Tube Light

WZ-T8-W18 T8 LED Tube Light WZ-T8-W18 T8 LED Tube Light Quick Details: T8 LED Tube 1.lumens:1450-1700Lm 2.warranty:2 years 3.certificate: CE & RoHS 4.lifespan:50,000h Feature: 1) Self designed and developed advanced constant current

More information

COSINE DEVELOPMENTS Reg. No. IT 1637/97

COSINE DEVELOPMENTS Reg. No. IT 1637/97 COSINE DEVELOPMENTS Reg. No. IT 1637/97 LEADERS IN LIGHTING TECHNOLOGY P O Box 10177 Tel. : +27 (31) 5793090/4 24 Ashfield Avenue Marine Parade Int. Fax. : +27 (31) 5793021 Springfield Park 4056 Local

More information

Handout Notes Major changes in BS : 2016

Handout Notes Major changes in BS : 2016 Handout Notes Major changes in BS 5266-1: 2016 The contents section now includes Introduction 1 Scope 2 Normative references 3 Terms and definitions 4 Consultation and records 5 Illumination for emergency

More information

Emergency light. Safe solutions

Emergency light. Safe solutions Emergency light Safe solutions Experience and know-how For more than two generations Glamox has developed, produced and distributed lighting solutions for the professional market. Emergency lighting has

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires Guidance Note Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires Guidance Document for testing and maintaining self-contained Emergency Lighting and Luminaires

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

LED Panel Light Specification List

LED Panel Light Specification List LED Panel Light Specification List Product Name: LED Panel Light Model No:LEDPAN1512 INUI Lighting Leading manufacturer of LED panel lights 0 ** Contents ** 1. Product Description 2 2. Application 2 3.

More information

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

EMERGI-LITE An authoritative guide to emergency lighting & central power systems

EMERGI-LITE An authoritative guide to emergency lighting & central power systems GUIDE EMERGI-LITE An authoritative guide to emergency lighting & central power systems Emergency lighting is a vital and effective life safety tool, providing reassurance and guidance to people at critical

More information

Emergency Lighting Guide. An authoritative guide to emergency lighting systems and design techniques

Emergency Lighting Guide. An authoritative guide to emergency lighting systems and design techniques Emergency Lighting Guide An authoritative guide to emergency lighting systems and design techniques The Emergi-Lite brand from Thomas & Betts delivers highly versatile emergency lighting solutions to a

More information

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH Safety through knowledge East Coast Safety Training Fire Safety Log Book Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH Tel: 07904163350 Website: Safety through knowledge East

More information

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up Part #: EPL-EMG-EXT-3W Page: 1 Made in the USA The EPL-EMG-EXT-3W Explosion Proof LED Exit Sign with back

More information

Emergency Lighting Design Guide

Emergency Lighting Design Guide Emergency Ligting Design Guide Step 1 Identify mandatory Points of Empasis for te positioning of luminaires, eamples as follows: FINAL EXIT EXIT SIGNS DIRECTION CHANGE INTERSECTIONS At eac eit door At

More information

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK The Mini-Max range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Mini-Max leads vandal-resistant IP65 technology. With

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

Dynamic Escape Routing System. D.E.R.-System. Sicherheitstechnik GmbH

Dynamic Escape Routing System. D.E.R.-System. Sicherheitstechnik GmbH Dynamic Escape Routing System D.E.R.-System Sicherheitstechnik GmbH D.E.R.-System New routes to safety Vision and resulting products Since the start of our company we work to bring ideas and visions regarding

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008 Irish Standard I.S. 3217:2008 Emergency Lighting NSAI 2008 No copying without NSAI permission except as permitted by copyright law. Incorporating amendments/corrigenda issued since publication: This document

More information

12W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor 12W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDSR12WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED IMPERIAL COLLEGE LIGHTING REVISION 1 LIGHTING Revision Log REV. COMMENTS REVISED BY DATE CHECKED APPROVED 1 First Issue NDY 18.03.05 Notes 1 Amendments to this specification are struck out and new added

More information

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features Maxim3 TM Series PROJECT NAME: CATALOG: NOTES: LED Vapor Tight - Waterproof Key Features Up to 146 IP66 87 UL 4, 5 & 8 K & K 110-277V NSF Stainless Steel Clips Operating Temp - o F to 105 o F 7 Year Warranty

More information

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY BEKA / EMERGENCY SIGNAGE FROM DAISALUX S.A. EMERGENCY ARGOS EMERGENCY SIGNAGE Ceiling Suspended Wall bracket VERSIONS/DIMENSIONS IN MM SINGLE SIDED Semi-recessed DOUBLE SIDED SEMI-RECESSED Surface CEILING

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

Low Location Lighting

Low Location Lighting Low Location Lighting system The spreading of smoke is one of the most dangerous consequences of a fire rendering evacuation difficult and in some cases impossible. Under these conditions, visibility is

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Fire Safety Register

Fire Safety Register Fire Safety Register Introduction 1.1 Section 18(2) of the Fire Services Acts, 1981 and 2003 generally applies to all premises other than a dwelling house occupied as a single private dwelling. This section

More information

700 Watt LED GROW LIGHT

700 Watt LED GROW LIGHT PRODUCT SPECIFICATIONS Product Name: Product Size 700 Watt LED GROW LIGHT 794mm x 334mm x 70mm PRODUCT DEFINITION LED Grow Light belongs to new generation grow and assistant grow light for plants. The

More information

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations A DETAILS OF THE CLIENT Client/ B DETAILS OF THE EMERGENCY LIGHTING INSTALLATION Extent of the installation covered by this certificate The Owner 19 Walker Grove, Hatfield, Hertfordshire 19 Walker Grove,

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

18W Round LED Wall/Ceiling Light with Microwave Sensor

18W Round LED Wall/Ceiling Light with Microwave Sensor 18W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDMR18WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

Canolux LED. Petrol Station Forecourt Luminaires

Canolux LED. Petrol Station Forecourt Luminaires Canolux LED Petrol Station Forecourt Luminaires Point source LEDs provide excellent opportunities to direct light accurately improving uniformity and reducing the electrical load. Well designed and manufactured

More information

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION M S Wright, G K Cook and G M B Webber Research Group for Inclusive Environments, The Department of Construction

More information

HRS Hand Rail System 1

HRS Hand Rail System 1 HRS Hand Rail System 1 Safety in tunnels Hand rail system for rail tunnels In accordance with the requirements of the TSI (technical specification for interoperability), all tunnels in the trans-european

More information

Saving on maintenance and energy

Saving on maintenance and energy K7 2 K7 ETAP ETAP K7 is a complete range of compact emergency lighting based on LED technology. It is designed to fully exploit all of the advantages of LEDs. Saving on maintenance and energy Reduced maintenance

More information

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications Simple Fit Switching Sensors 1.8m to 3m Cone-shaped detection pattern, 6m radius at mounting height 6.0m AC220~240V/50Hz MK Simple Fit Sensors offer cost effective presence detection for lighting control

More information

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC Product Guide EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC Ceiling PIR presence/absence detector 2 channel Overview The EBDSPIR-PRM-2CH PIR (passive infrared) presence detector provides automatic control of lighting

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

Construction site lighting INFORMATION PACKAGE. mberg.com. Construction site lighting information package 1 (16)

Construction site lighting INFORMATION PACKAGE. mberg.com. Construction site lighting information package 1 (16) Construction site lighting INFORMATION PACKAGE mberg.com Construction site lighting information package 1 (16) REQUIREMENTS OF CONSTRUCTION SITE LIGHTING Level of lighting on construction sites Correctly

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

CoreLine Waterproof the clear choice for LED

CoreLine Waterproof the clear choice for LED Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note GN Published by Rail Safety and Standards Board Evergreen House 160 Euston Road London NW1 2DX Copyright 2007 Rail Safety and Standards Board Limited GI/GN7520 Issue 1 December 2007 Railway Group Guidance

More information

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS LED EMERGENCY DRIVER

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent

More information

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Maxos LED General Lighting innovative, flexible solution delivers ideal light output Lighting General Lighting innovative, flexible solution delivers ideal light output Customers in the industrial and retail sectors are looking for general lighting solutions with a justifiable payback,

More information

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

SmartBalance recessed combining performance with smart design

SmartBalance recessed combining performance with smart design Lighting SmartBalance recessed combining performance with smart design Many people are keen to apply recessed luminaires with a surface of light as an alternative to louver-type solutions. At the same

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

AS/NZS :2006 Interior and workplace lighting - Part 1: General principles and recommendations

AS/NZS :2006 Interior and workplace lighting - Part 1: General principles and recommendations Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 1680.1:2006 Interior and workplace lighting - Part 1: General principles and recommendations Table of Contents

More information

2-ZONE EASYFIT INTRUDER ALARM

2-ZONE EASYFIT INTRUDER ALARM EXTERNAL SIREN MM05 PIR SENSOR DOOR CONTACTS -ZONE EASYFIT INTRUDER ALARM INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THIS ALARM

More information

IDOO.PENDANT POWER OVER ETHERNET (PoE) SUSPENDED LUMINAIRE

IDOO.PENDANT POWER OVER ETHERNET (PoE) SUSPENDED LUMINAIRE IDOO.PENDANT POWER OVER ETHERNET () SUSPENDED LUMINAIRE IDOO.pendant, Waldmann`s suspended direct/indirect luminaire with a strikingly slim profile, provides both uniform, glarefree illumination at the

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

LED TRACK LIGHT.

LED TRACK LIGHT. LED TRACK LIGHT Application Places Hotel, meeting room, factory, office, bar, coffee house, residential, show room, Institution Buildings, School, hospital, Places where there require high rendering index

More information

Emergency Assist Alarm Kit Single Zone

Emergency Assist Alarm Kit Single Zone Emergency Assist Alarm Kit Single Zone Model: EASZKN Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications Lighting UniStreet simple, costeffective road-lighting range UniStreet At relatively low initial cost, the highly efficient LED-based UniStreet luminaire offers significant cost savings compared with conventional

More information

w w w. l e t t h e r e b e l i g h t. c o m. a u

w w w. l e t t h e r e b e l i g h t. c o m. a u w w w. l e t t h e r e b e l i g h t. c o m. a u The following presentation will give you a general overview of lighting and its importance in the commercial, industrial and retail work environment and

More information

Title: Room-sealed fanned draught flue systems concealed within voids

Title: Room-sealed fanned draught flue systems concealed within voids Date issued: 11 th June 2007 Author: Jamie Cooper Status: Current Reviewer: 11 th June 2008 Introduction Title: Room-sealed fanned draught flue systems concealed within voids With the advent of modern

More information

FIRE SAFETY LOG BOOK

FIRE SAFETY LOG BOOK FIRE SAFETY LOG BOOK Regulatory Reform (Fire Safety) Order 2005 If you own, manage or operate a business, you will need to comply with fire safety law. The main law is the Regulatory Reform (Fire Safety)

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

MWS3 Ceiling Mount Microwave Occupancy Detector

MWS3 Ceiling Mount Microwave Occupancy Detector MWS3_0916/ISSUE1 MWS3 Ceiling Mount Microwave Occupancy Detector Description: the MW3SA offers a unique presence/absence detection capability by using an adjustable head. This incorporates an innovative

More information

RF Programmable Room Thermostat Installation Instructions

RF Programmable Room Thermostat Installation Instructions ESRTP4RF RF Programmable Room Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect

More information

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system MSensor 02 Multi-sensor for system Product description Component of the comfortdim system ( standalone) With ambient light dependent control and motion detection Simple group assignment via rotary switch

More information

Requirements of EN 1838: illuminance of 5 lx for safety equipment

Requirements of EN 1838: illuminance of 5 lx for safety equipment GuideLed SL 151, 152 CG-S Ceiling recessing, ceiling surface-mounting for illuminance of 5 lx vertically Requirements of EN 1838: illuminance of 5 lx for safety equipment Te aim of emergency ligting is

More information

360º Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller 360º Surface Mount Ceiling PIR Light Controller Model: PDRS1500 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

60W Multi PIR Bulkhead

60W Multi PIR Bulkhead 60W Multi PIR Bulkhead Model: MLB98 Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon

More information

Selecting And Applying Emergency Lighting Systems

Selecting And Applying Emergency Lighting Systems bodine Selecting And Applying Emergency Lighting Systems A revision of an article originally published in Electrical Construction & Maintenance by David Crippen, CEO & Marketing Manager Contains updated

More information

360 Ceiling PIR Light Controller

360 Ceiling PIR Light Controller 360 Ceiling PIR Light Controller Model: SLFM360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life 0118M Series Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION High light efficiency Energy saving Long life Led surface mounted panel lights can be made in any shape or size to replace

More information

LED EMERGENCY LIGHTING

LED EMERGENCY LIGHTING 600PAN + EBPM3 LDLEM3 SIGNLEDEM3 EXIT3MLED EMLED3M CSLEDWHEM3 ALEM3WHGRI LED Panel + LED Non Maintained Emergency Battery Pack Emergency Downlight LED Emergency LED Maintained Hanging Exit Sign Light Emergency

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

5W LED Energy Saver PIR Bulkhead

5W LED Energy Saver PIR Bulkhead 5W LED Energy Saver PIR Bulkhead Model: LED88PIR Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human

More information

Installation & Operating Instructions

Installation & Operating Instructions Emergency Assist Alarm Models covered: EACP1 Single Zone Plastic Control Unit (with battery backup EACP1PR) EASSCP1 Single Zone Stainless Steel Control Unit (with battery backup EASSCP1PR) EARB1 Plastic

More information

ipanel LED Panel Light

ipanel LED Panel Light ipanel LED Panel Light -replacement for fluorescent luminaires, with dimming and emergency A U S T R I A TUV-CE (EMC) TA380130384 TUV-CE (LVD) TA380130310. Ordering ipanel-xxxx-aa-bb-ccc XXXX= size 6060

More information

Movement Detector GJD 300

Movement Detector GJD 300 Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

2-ZONE EASYFIT INTRUDER ALARM

2-ZONE EASYFIT INTRUDER ALARM SIREN PIR SENSORS MM084 MM44 MAINS ADAPTOR DOOR CONTACTS Please note: Before you start to install this Micromark Alarm, we advise that you should take adequate safety precautions when using power tools

More information

HIGH BAY APPLICATIONS

HIGH BAY APPLICATIONS STAIRWELLS The IIS Inverter can operate multiple fixtures in a building s stairwell and can be wired to bypass dimmers or occupancy sensors...keeping your egress corridors lit without sacrificing your

More information

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B Dear Customer Please find enclosed Amendment 4, effective 14 February 2014, to the Acceptable Solution and Verification Method for Clause F8 Signs of the New Zealand Building Code. THe previous amendment

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES VISAGE ENVIRONMENTAL LIGHTING SOLUTION INDOOR Lighting SERIES LED Lighting Concept LED, known as Light Emitting Diode, uses solid semiconductor chips as luminescent material. When put the forward voltage

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

Lighting of the future

Lighting of the future Lighting of the future LIGHTFIT the only LED-system, that makes the exchange of all the individual components possible without tools! Modularity Modular pluggable system consisting of: LED light source

More information