[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

Size: px
Start display at page:

Download "[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation"

Transcription

1 Refrigeration Innovation Thermo Simple 2 Manual Refrigeration Innovation, LLC Harter Avenue, Suite E Woodland, CA Ph: Fx: Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 1 of 22

2 TABLE OF CONTENTS TABLE OF CONTENTS... 2 HARDWARE CONFIGURATIONS... 3 MULTI NODE (SPINE) CONFIGURATIONS... 3 Power Supply for Multi Node... 3 Junction Box (For Single Temperature Case)... 4 Junction Box (For Dual Temperature Case)... 5 Junction Box (Analog Output)... 5 Temperature vs. Voltage Chart... 6 SINGLE NODE CONFIGURATION... 7 Power Supply... 7 Dual temperature Power harness... 7 HARDWARE INSTALLATION... 9 HOLES PATTERN... 9 MOUNTING SCREWS... 9 DISPLAY UNIT DISPLAY MAGNETIC SWITCHES FEATURES AND FUNCTIONS Basic Functions Service Request (Advanced) Functions Device Alarm Set Point Set Points [dt] Dual Temperature [0.0] 0.0 Fahrenheit [5.0] 5.0 Fahrenheit and/or Dual Temp Low Setting [36.0] 36.0 Fahrenheit [40.0] 40.0 Fahrenheit and/or Dual Temp Hi Setting [43F] 43.0 Fahrenheit with Freeze Alarm [52.0] 52.0 Fahrenheit [57F] 57.0 Fahrenheit with Freeze Alarm [142] 142 Fahrenheit for Hot Foods Enabling/Disabling Defrost (def) Alarm Flag WARRANTY Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 2 of 22

3 HARDWARE CONFIGURATIONS MULTI NODE (SPINE) CONFIGURATIONS This configuration allows a single power supply to power up to 6 Thermo Simple 1 and/or 2. Power Supply PN: PS Spine Cable 6 feet PN: Spine 6 Junction Box (Single Temp.) PN: ST 3 Junction Box (Dual Temp.) PN: ST 3 DT Spine Cable 13 feet PN: Spine 13 Spine Cable 25 feet PN: Spine 25 Power Harness PN: H2 S Sensor 6 feet PN: H3 6 Sensor 13 feet PN: H3 13 Sensor 25 feet PN: H3 25 Display Unit PN: TS2 DS Power Supply for Multi Node The power supply for Multi Node Configuration is not interchangeable with Single Node power supply. This is due to different load requirements. INPUT Plug type: NEMA 1 15p Voltage: Vac(50 60 Hz) Current: 0.2 A OUTPUT Plug type: RJ45 (8 Positions 8 Contacts) Voltage: 12 Vdc Current: 1.5 A Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 3 of 22

4 Junction Box (For Single Temperature Case) There are three RJ45 receptacles. The main power receptacles are the 2 on left and right hand side. The third receptacle on the bottom provides regulated power output for Thermo Simple thermometers. NOTE ON JUNCTION BOX CONNECTIONS: DO NOT connect Thermo Simple Power harness, H2 harness, into any of the 2 main power receptacles. DO NOT connect Power Supply or Spine cable, into the third output receptacles. For proper connection please refer to the Multi Node (Spine) Configuration diagram. SPINE Port: Connect Power Supply or Spine Cable here. WARNING: DO NOT connect H2 S Power harness in here. Thermo Simple Port: Connect Power harness (H2 S) here. WARNING: DO NOT connect Power Supply or Spine cable in here. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 4 of 22

5 Junction Box (For Dual Temperature Case) For dual temperature case, the set point can be automatically switched between 5.0 F and 40.0 F depending on the Dual Temperature switch on the case. Therefore when the dual temperature case is switch between Frozen Food Case to Fresh Food Case, the display unit will automatically change its set point to match the case temperature setting. This is for use only with 120v Low Temp solenoid applications. For dry contact applications see Page 8 For use with 120 VAC Low Temperature Solenoid Application Voltage input from low temperature solenoid goes here. There is no polarity ( Hot and Neutral at 120Vac) Junction Box (Analog Output) For wired analog output application, the display unit temperature is expressed in voltage. The voltage can be measured from the DAC OUT connector. It can be wired to any analog input boards in EMS Controller. EMS controller requires 0 5 VDC Analog Input Board and setting prior to connecting wires from ST 3 to analog input point. Analog Output (Volt DC) Top: + Bottom: /Common Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 5 of 22

6 Temperature vs. Voltage Chart Voltage C F Voltage C F To setup the EMS Controller Analog Input Linear Analog Input set to Fahrenheit, voltage offset of: V and Gain of Linear Analog Input set to Centigrade, voltage offset of: V and Gain of Alternate Setting with 2 End points: 0 Volts = 32 C ( 25.6 F) 5 Volts = C ( F) Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 6 of 22

7 SINGLE NODE CONFIGURATION Node configuration is suitable for stand alone cases. Power Supply PN: PS Single Temp. Power Harness PN: H2 N Dual Temp. Power Harness PN: H2 N DT Sensor 6 feet PN: H3 6 Sensor 13 feet PN: H3 13 Sensor 25 feet PN: H3 25 Dual Temp. Input Not available on Single Temp. Power Harness Display Unit PN: TS2 DS Power Supply INPUT Plug type: NEMA 1 15p Voltage: Vac (50 60 Hz) Current: 0.2 A OUTPUT Plug type: Molex 2 Pin Voltage: 12 Vdc Current: 0.35 A Dual temperature Power harness For dual temperature case with Dry Contact switch control. The dual temperature cable wire is orange and white orange. There s no polarity. The wires connect to the switch in series. With Dual Temp power harness the set point can be automatically switched between 5.0 F (Low Temperature) and 40.0 F (Medium Temperature) depending on the Dual Temperature switch position on the case. When the switch is open, the set point becomes F (Medium Temperature). When the switch is close, the set point becomes +5.0 F (Low Temperature). Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 7 of 22

8 When the case switches from F (Medium Temperature) to +5.0 F (Low Temperature) there will be a 30 minute delay to allow time for the case to cool down. However, when the case switches from +5.0 F (Low Temperature) to F (Medium Temperature) there will be no delay. When the dual temperature case is switch between Frozen Food Case to Fresh Food Case, the Thermo Simple will change between +40 and +5 settings immediately. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 8 of 22

9 HARDWARE INSTALLATION HOLES PATTERN Here is the holes dimension to make the cut out. MOUNTING SCREWS Please use #8 pan head self tapping sheet metal screws for mounting. #8 Self Tapping Pan Head Sheet Metal Screws Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 9 of 22

10 DISPLAY UNIT DISPLAY Incoming Data Indicator (wireless system only) Temperature Scale Positive/Negative Temperature indicator Outgoing Data Indicator (wireless system only) Numeral Indicator (Temperature/Set Point/ Device s Address/Status) TS.2 displays temperature in its default state. It also displays incoming and outgoing communication between the device and the wireless network a wireless system. MAGNETIC SWITCHES Thermo Simple 2 /TS.2 Switch Function switch M/L Switch Set point switch F/C Switch Temp. scale switch To trigger a magnetic switch on the TS.2 device, a Refrigeration Innovation Magik Wand is needed. The Magik Wand can be purchased from RI to ensure that the switches are triggered properly. In absence of a Magik Wand, the magnetic switches on a TS.2 device can be triggered by any strong magnet (Neodymium rare earth type. A typical refrigerator door magnet or whiteboard magnet are NOT strong enough). Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 10 of 22

11 FEATURES AND FUNCTIONS The basic switch functions can be used to temporarily change the temperature scale or display the currently active set point. There are also arrays of advanced switch sequences to change the default temperature scale, change active set points, and obtain or delete the device address in a wireless system. Basic Functions Switch Assignment Description F/C Temporarily Change Temperature Units Turn on red LED, display temperature in Centigrade. Temperature automatically reverts back to Fahrenheit in approximately 10 seconds. If any LEDs are flashing from any previous command, triggering this switch will clear the flashing LEDs and any displayed address on the screen. Note: This will not clear an active Alarm. M/L Display active set point Turn on green LED, display current alarm set point temperature. Thermo Simple 2 (TS.2) Function/Service Request trigger Turn on blue LED. TS.2 switch, this is a function switch which is enabled for 2 1/2 seconds after triggering. While the Blue LED is lit, triggering other switches will invoke various advanced functions and settings Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 11 of 22

12 Service Request (Advanced) Functions Switch Sequence Assignments Descriptions TS.2 F/C Set the default temperature display to the opposite of what is currently displayed From the factory, the default temperature display is Degrees Fahrenheit. Triggering this function will set the default to Degrees Centigrade. If triggered during a Defrost cycle, this will override the display of def on the Display. This allows reading of the actual temperature during a Defrost cycle. This override will not change the default temperature units and is only in effect for one Defrost cycle. The next Defrost cycle will display def as normal. TS.2 M/L Select/Change alarm setpoint While the set point is flashing on the display, triggering of the M/L switch will successively change the set point to the next pre programmed set point. This will cycle through all the set points as long as the display is flashing. Allowing the display to stop flashing will assign the new set point that is displayed. Note: Setting the dt mode for Dual temp cases allows the set point to be automatically modified with the case switch between 5 F and 40 F for low and medium temperatures respectively. F/C M/L Toggle Defrost On/Off This toggles Defrost function on or off. When Defrost function is turned on: The display unit will show def when the case is out of Set point temperatures for the first time. When Defrost function is turned off: The display unit will keep showing temperature when the case is out of Set point temperatures for the first time. After the first 60 minutes the unit will go into alarm. TS.2 TS.2 Auto assign the device address to the next available address. WiDAQ (wireless) system only TS.2 + TS.2, triggers the Function switch once to light the Blue LED then triggers it again within 2 1/2 seconds to light the Green LED. After 2 seconds the Blue LED will start flashing which allows the unit to start communicating to the WiDAQ wireless network and will enable the Thermo Simple to acquire a network address. The newly assigned network address should show up on the display. If an address has been previously assigned to the unit then it will display the address that has been assigned. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 12 of 22

13 TS.2 TS.2 M/L Clear an assigned address and stop device communication WiDAQ (wireless) system only TS.2 + TS.2 + M/L switches will clear any assigned address and cause the unit to stop responding to commands from the WiDAQ wireless network. After the Unit s address has been cleared, the F/C switch can be triggered to clear the flashing LED and display. TS.2 TS.2 [TS.2 & HOLD] Manually assign the device address. Thermo Simple unit MUST NOT have previously assigned address. Previous address number must be cleared first WiDAQ (wireless) system only TS.2 + TS.2 + [TS.2 & HOLD], trigger the Function switch once to light the Blue LED. Trigger it again within 2 1/2 seconds to light the Green LED. Trigger and hold for auto increment, or tap until the desired address number is shown. The Blue LED will flash briefly and allow the unit to start communicating to the WiDAQ wireless network using the manually assigned network address. This is intended to allow replacement of a device that already has an address on the WiDAQ network with a new device using that same address. Note: Use of an address that is already assigned to another device on the network will cause malfunction of both devices. Device Alarm Set Point The set point configures the device to operate in the range of temperature for that particular case. The set point determines whether the case temperature is within range or not and determines when the unit goes into alarm. To View the current Set point of a device tap the M/L switch. Hint: Once a switch is tapped pull the magnet at least ½ away from the switch to allow it to turn off. Magnet End To check the current Set point, tap the magnet end here to display the current Set Point. Make sure to pull the magnet at least ½ away from the switch after a tap. Tap M/L once only To Change the current Set point of a device tap the Thermo Simple 2 switch followed by M/L switch. Keep tapping M/L Switch until the desired set point is shown. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 13 of 22

14 Magnet End Tap TS.2 once FIRST To change the current Set point, tap the M/L switch once, (within 2 seconds of TS.2 switch). Tap M/L once only Keep tapping the M/L switch to cycle through the available Set points. Stop on the desired Setpoint to set it. Set-Points There are slight differences between LED color schemes on different set points. There are also differences in alarm and alarm delay schemes between different set points. Optional Red Alarm is only applicable if it has been enabled from the factory. On most units the Red alarm is NOT enabled. Hence, the Amber Alarm will stay on after 2 hours. For different temperature ranges on different types of cases there are 9 Set points. They are as follows: [dt] Dual Temperature The dual temperature set point is a variable set point. The dt set point toggles between 5.0 F set point for low setting and 40.0 F set point for medium setting. [0.0] 0.0 Fahrenheit LED COLOR and STATE DESCRIPTIONS SOLID BLUE on BGA SOLID GREEN on GAR Below set point. ( 2 degree Fahrenheit) SOLID BLUE on BGA SOLID GREEN on GAR At set point. (0 degree Fahrenheit) Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 14 of 22

15 SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Ice Cream Frozen Food [5.0] 5.0 Fahrenheit and/or Dual Temp Low Setting LED COLOR and STATE DESCRIPTIONS SOLID BLUE on BGA SOLID GREEN on GAR Below set point. (0 degree Fahrenheit) SOLID BLUE on BGA SOLID GREEN on GAR At or below set point. (5 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 15 of 22

16 FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Ice Cream Frozen Food [36.0] 36.0 Fahrenheit LED COLOR and STATE DESCRIPTIONS SOLID GREEN Below set point. (34.4 degree Fahrenheit) SOLID GREEN At or below set point. (36 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Fresh Meat Fresh Fish Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 16 of 22

17 [40.0] 40.0 Fahrenheit and/or Dual Temp Hi Setting LED COLOR and STATE DESCRIPTIONS SOLID GREEN Below set point. (34.4 degree Fahrenheit) SOLID GREEN At or below set point. (40 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Fresh Meat Fresh Fish [43F] 43.0 Fahrenheit with Freeze Alarm LED COLOR and STATE DESCRIPTIONS FLASHING BLUE on BGA FLASHING RED on GAR Below freezing point. (Freeze Alarm starts at 33.5 degree Fahrenheit) Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 17 of 22

18 SOLID GREEN At or below set point. (43 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Fresh Produce Fresh Fruits [52.0] 52.0 Fahrenheit LED COLOR and STATE DESCRIPTIONS SOLID GREEN Below set point. (40 degree Fahrenheit) SOLID GREEN At or below set point. (52 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 18 of 22

19 FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Cheese Delicatessens [57F] 57.0 Fahrenheit with Freeze Alarm LED COLOR and STATE DESCRIPTIONS FLASHING BLUE on BGA FLASHING RED on GAR Below freezing point. (Freeze Alarm starts at 33.5 degree Fahrenheit) SOLID GREEN At or below set point. (57 degree Fahrenheit) SOLID PURPLE & def Above set point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set point for more than 60 minutes. FLASHING RED (on GAR only) Optional Above set point for more than 120 minutes. (Second Alarm after Amber Alarm) Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 19 of 22

20 Suggested Product for this Set point: Fresh Milk Dairy Products [142] 142 Fahrenheit for Hot Foods LED COLOR and STATE DESCRIPTIONS Case heaters are off or have been on for less than 60 minutes. NO COLOR Device assumes case is heating up for the first 60 minutes in this set point. SOLID GREEN Case has reached or is above set point. (Above 142 degree Fahrenheit) FLASHING AMBER Case has never reached set point or has been below set point for more than 60 minutes. Device assumes case failure and triggers the Amber Alarm. Any food should be removed until the case is repaired. Case has been below the set point for more than 4 hours. FLASHING RED If prepared food has been in the case up to a Red Alarm the food should be discarded. (Second Alarm after Amber Alarm) Suggested Product for this Set point: Hot Foods Prepared Foods Enabling/Disabling Defrost (def) In some applications, there is a need to disable the Solid Purple Defrost state. This may happen in a walk in case where the door is opened and closed often. Disabling Defrost will cause the device to continue displaying temperatures even when the temperature is above the set point. An over Temp condition will still go into Alarm if the temperature stays above the set point for more than 60 minutes. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 20 of 22

21 Magnet End To enable/disable Defrost Notification: Tap the F/C switch once then tap the M/L switch once, (within 1 second of the F/C switch). Off on display means the Defrost state has been disabled. On on display means the Defrost state has been enabled. THEN Tap M/L Tap F/C here FIRST Alarm Flag If the unit ever went out of temperature the display unit will alternate between temperature reading and ALA. This means that even though the case is back in temperature, it has been out of temperature for more than 60 minutes previously. First 60 minutes after defrost timer is up (70 minutes on set points with freeze alarm) The units will shows ALA on display along with flashing amber/yellow for the first 60 minutes after 60 minutes defrost timer is up. (70 minutes after 70 minutes defrost timer is up on set point with freeze alarm) Master Alarm will turn on within 60 minutes (Wireless System Only) Display Alternates After an alarm condition has gone away The unit will go back to normal operation, however the display will alternate between ALA and the actual temperature, alternating approximately every three seconds. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 21 of 22

22 Magnet End To clear the alarm condition, Tap F/C here FIRST Tap F/C switch once using a RI Magik Wand or any strong magnet. Once the temperature goes back below (or over, for hot food set point 142F), the TS.2 unit will display the temperature and ALA repetitively until F/C switch has been triggered. WARRANTY 2 Year Warranty Thermo Simple 2 from Refrigeration Innovation, (the "Product"), is warranted against defects in materials and workmanship under normal use, for a period of 2 years from the date of purchase. In the event of a product failure due to materials or workmanship, Refrigeration Innovation will repair or replace the defective product. For warranty service, return the defective product to Refrigeration Innovation, shipping prepaid, for prompt repair or replacement. The foregoing sets forth the full extent of Refrigeration Innovation s warranties regarding the Product. Repair or replacement at Refrigeration Innovation s option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND REFRIGERATION INNOVATION SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL REFRIGERATION INNOVATION, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOSS OF PRODUCT, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply. Refrigeration Innovation, LLC Harter Ave., Suite E, Woodland, CA Page 22 of 22

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

2-Port alarmcharge Hub - Manual

2-Port alarmcharge Hub - Manual Installation Manual 1. What s in the box 2. Fixture preparation 3. Mounting 4. Mechanical 5. Device power Operation Manual 6. Device connectors and connections 7. Alarming remote control 8. Safety 9. Warranty

More information

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc. Installation Manual 000 Version.0 EXP-000 HBX Control s Inc. Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

1F90-60 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems)

1F90-60 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems) OPERATION GUIDE 1F90-60 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems) WHITE-RODGERS Operator: Save this booklet for future use! About Your New Thermostat... Your new White-Rodgers Digital

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com

More information

SYSTEM CONTROL KIT Model: CK-41P

SYSTEM CONTROL KIT Model: CK-41P SYSTEM CONTROL KIT Model: CK-41P READ THE INSTALLATION INSTRUCTIONS CAREFULLY & COMPLETELY BEFORE BEGINNING THE INSTALLATION! Designed for use with the SWG Series Power Venter for controlling Natural Gas

More information

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Vapor Tight Linear Fixture General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533

More information

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12 PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting

More information

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C) INSTALLATION/OPERATING INSTRUCTIONS TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C) The TMC displays and monitors a system's temperature and provides an alarm light and

More information

OPERATING MANUAL/ INSTALLATION

OPERATING MANUAL/ INSTALLATION NHW- 15 HOT WATER MACHINE OPERATING MANUAL/ INSTALLATION 120/240 V 1650/6600 W US 120/240 V 1350/5500 W CAN CONVERTIBLE 2 GA LLON DRIP TRAY INCLUDED ADVANCED TEMPERATURE CONTROL TVT TECHNOLOGY NEWCO ENTEPRISES

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC PitBoss User Manual Version 1.5 10/24/2013 Copyright 2013 PumpAlarm.com, LLC www.pumpalarm.com 1 CONTENTS Introduction... 4 How Does the PitBoss Work... 4 What Comes With Your PitBoss... 5 Getting to Know

More information

120 VAC SYSTEM CONTROL KIT Model: CK-63

120 VAC SYSTEM CONTROL KIT Model: CK-63 120 VAC SYSTEM CONTROL KIT Model: CK-63 Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls. The CK-63 control has the ability to operate

More information

NT DUAL CHANNEL DISPLAY. User Guide

NT DUAL CHANNEL DISPLAY. User Guide NT DUAL CHANNEL DISPLAY User Guide Table of Contents Introduction... 2 Input Signals... 2 Output Signals... 2 User Programmable Features... 2 Installation... 3 Mechanical Installation... 3 Dimensional

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1. TH146-N-2H1C Installation Guide Non-programmable H/C Controller Removable Connector * Removable Connector * TH146 User Console CT280-2H1C Control Module AC144-03 Outdoor Temperature Sensor * To remove

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement

More information

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control PLL Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it

More information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information Model 8800 Universal Communicating Thermostat Owner s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS 61000762A 8800 Tstat Owners.indd 1 3/28/11 4:19:57

More information

Installation and Owner Man u al

Installation and Owner Man u al T H R E E P H A S E Evaporator Fan Control System Installation and Owner Man u al WARNING The installation of this device should be done only by competent personnel, experienced in electrical wiring, and

More information

ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces. User s Guide

ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces. User s Guide ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces User s Guide Welcome to ATMOX This User s Guide will cover the basic operation of the ATMOX System. For instructions on installation,

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it should

More information

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Users Manual. LAURUS Systems, Inc. - Ph: Fax: Users Manual LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com Introduction The rad-d is a security and inspection system that detects emissions from radioactive material.

More information

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Operating Instructions READ AND SAVE THESE INSTRUCTIONS Operating Instructions READ AND SAVE THESE INSTRUCTIONS Aprilaire Communicating Thermostat Model 8870 CAUTION: Do not set to OFF mode during periods when freezing temperatures could occur. Thank you for

More information

DOLKPL1KB DOLKPS1KB DOLKSF1KB

DOLKPL1KB DOLKPS1KB DOLKSF1KB DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL INSTRUCTIONAL VIDEO 1] Connection Terminals 2] Basic Wiring Example 3] Quick Start Guide 4] Programming Guide 5] Specifications 1 Connection Terminals The DOLKPS1KB/DOLKPS1KB/DOLKSF1KB

More information

BACKUP BATTERY INSTALLATION INSTRUCTIONS

BACKUP BATTERY INSTALLATION INSTRUCTIONS www.tiltlights.com BACKUP INSTRUCTIONS A Lauren International Company www.laurenillumination.com 855 440 8458 LdPE7-2014 SELf-TESTINg EmERgENCY LEd driver RATINGS: Input: 100-277 VAC 50 or 60 Hz Output:

More information

Portable Refrigerator

Portable Refrigerator Portable Refrigerator Owners Manual Single door 40 litre 65 litre 80 litre 125 litre Double door 74 litre 95 litre 2009 Introduction The National Luna range of portable fridges and freezers are high-performance,

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1 Chore-Logic User manual Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07 Page 1 Warranty Chore-Time Hog Production Systems, a division of CTB, Inc., ( Chore-Time ), warrants each new Chore-Time product

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

7-Day. Digital Thermostat. residential. & 2-cool

7-Day. Digital Thermostat. residential. & 2-cool Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In

More information

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc. Installation Manual M-000 Setpoint Thermostat Version.04 M-000 HBX Control Systems Inc. TABLE OF CONTENTS Introduction Index Safety symbols and Warnings Index Receipt and Inspection Description Technical

More information

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail Manufacturers of Process Controls and Instrumentation Instruction Manual Model: Function: Input: PCS-400-XY Pump Controller X=2: 4-20 ma X=5: 1-5 VDC X=6: 0-10 VDC X=7: Output: Power: 4 Pump Control Relays

More information

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. SYSTEM CONTROL KIT Model: CK-20F and CK-20FG (NOTE: CK-20FG units are designed for the Flame Guard units built by American Water Heater. All other manufacturers use CK-20F) Designed for use with the SWG

More information

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24 OWNER'S MANUAL P/N P374-1000FM 1 For All Programmable or Non-Programmable Switchable Digital Thermostat 72 74 Am AUTO 70 Mounts Flush to the Wall 1 Day Programmable or Non-Programmable 4 Time Periods per

More information

Blade Series Heat Exchanger Operation and Installation

Blade Series Heat Exchanger Operation and Installation Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information

More information

Owner s Manual MODEL 8555

Owner s Manual MODEL 8555 110-793B 7/11/01 3:29 PM Page 1 ELECTRONIC THERMOSTAT Owner s Manual MODEL 8555 7 Day Programmable Thermostat 110-793B 7/11/01 3:29 PM Page 2 OWNER S MANUAL TABLE OF CONTENTS ENERGY STAR Program Information............................................................

More information

Installation Instructions

Installation Instructions Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................

More information

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

1 For All Programmable Digital Thermostat. Meets Residential California Title 24 OWNER'S MANUAL P/N P374-1100FM 1 For All Programmable Digital Thermostat 72 74 Am I2:00 AUTO 70 unts Flush to the Wall 7 Day Programmable 4 Time Periods per Day Auto Changeover Large, Easy To Read Display

More information

Quest Power Electric Heat EHS 62 Pro

Quest Power Electric Heat EHS 62 Pro Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection

More information

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG 24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt

More information

Programmable HEPA Air Purifier

Programmable HEPA Air Purifier Programmable HEPA Air Purifier Model 30130 Models 30170, 30175 & 30185 Model 30130 30170, 30175, 30185 30400, 30401 Model 30400 & 30401 Replacement Filter Information Pre-Filter 30901 30901 30901 www.hunterfan.com

More information

RC-2000 Thermostat Installation Instructions

RC-2000 Thermostat Installation Instructions RC-2000 Thermostat Installation Instructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The RC-2000 will support the following systems: Single

More information

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly

More information

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08 Digital Thermostat residential THERMOSTAT 5+2 DAY PROGRAMMABLE up to 1-heat & 1-cool PUMP Stages: 1-Heat, 1-Cool Battery or System Powered Back-Lit Digital Display Fahrenheit or Celsius Service Filter

More information

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H Instruction Manual US PAT: 6,824,069 6,786,421 Models: CT03TS21 CTO3TS32 CTO3TS32H www.climatouch.com AED Electronics Inc. 5758 Royalmount Avenue Montreal, Quebec,Canada H4P 1K5 Technical Support: 1-866-90TOUCH

More information

Programmable Digital Thermostat

Programmable Digital Thermostat OWNER'S MANUAL P/N P474-2150 1 For All Programmable Digital Thermostat Mo TOTALINE 72 74 COOL AUTO HEAT 70 Optional Locking Cover Meets California Title 24 Dual Setpoint 5+1+1 Day Programmable 3 Occupied,

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 6303 & 6302 Zoned Comfort Control Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61001212A 6302-6303 Zoned Comfort Control Install.indd 1 TABLE OF CONTENTS SAFETY INSTRUCTIONS..........................................

More information

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

QD-ENG-68 Controller for Thermoelectric Thermal Management

QD-ENG-68 Controller for Thermoelectric Thermal Management INSTALLING THE CONTROLLER QD-ENG-68 Controller for Thermoelectric Thermal Management The Ice Qube TMS controller is shipped complete with mounting hardware and electrical cables for easy installation.

More information

Secondary Sensing System

Secondary Sensing System Secondary Sensing System Owners Manual Hired Hand Mfg., Inc. 1733 Co Rd 68 PO Box 99 Bremen, Alabama 35033 Manual No. 4801-2997 Rev 7-04 Owners Manual Secondary Sensing System Table of Contents Section

More information

GEYSERWISE INSTRUCTION MANUAL

GEYSERWISE INSTRUCTION MANUAL GEYSERWISE INSTRUCTION MANUAL GEYSERWISE MAX DELTA T ALL IN ONE HOT WATER MANAGEMENT Before operating and installation, carefully read all instructions. Do not discard this manual. INDEX 1. Package Contents

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700 INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 700 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

MR3CCUHV Temperature/Defrost Control

MR3CCUHV Temperature/Defrost Control Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature

More information

Document No

Document No CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1

More information

TJERNLUND PRODUCTS, INC.

TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com PRESSURE SWITCH AND INSTALLATION WITH

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad Carrier Heating & Cooling TSTATCCNB00 NON-PROGRAMMABLE DIGITAL THERMOSTAT USER INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW THERMOSTAT NON-PROGRAMMABLE DIGITAL THERMOSTAT AUTO 74 Dual

More information

CA5000 Liquid CO 2 Freezer Backup System

CA5000 Liquid CO 2 Freezer Backup System CA5000 Liquid CO 2 Freezer Backup System OPERATING INSTRUCTIONS MANUAL HAMPSHIRE CONTROLS CORPORATION ONE GROVE STREET / P.O. BOX 516, DOVER, NEW HAMPSHIRE USA 03821 TEL. (603) 749-9424 FAX (603) 749-9433

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

User Guide. for the Beacon ProActTM 200 System

User Guide. for the Beacon ProActTM 200 System TM User Guide for the Beacon ProActTM 200 System BEACON recommends that this product, like all sump pumprelated products, be installed by or under the supervision of a professional plumbing contractor.

More information

HAI Omni-Bus Network Installation. 5. Typical Application

HAI Omni-Bus Network Installation. 5. Typical Application HAI Omni-Bus Network Installation 5. Typical Application HAI Omni-Bus Network Installation Notes 1. Network cable 2. Crimp Connectors 3. Network Termination Plug 4. Jumpers 5. Splitters 6. Power Supply

More information

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93 Operating Instructions EN Temperature and Humidity EC Control Model 35YV93 479702 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE

More information

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Owner s Manual. 5+2 Day Programmable Digital Thermostat Model Air Conditioning & Heating 5+2 Programmable Digital Thermostat 1-Heat & 1-Cool Heat Pump Compatible Battery or System Powered Backlit Digital Display Fahrenheit or Celsius Service Filter Indicator

More information

Owner s Manual Hydro-X Vacuum Pac

Owner s Manual Hydro-X Vacuum Pac 4201 Lien Rd Madison, WI 53704 Owner s Manual Hydro-X Vacuum Pac Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Hydro-X Vacuum Pac outperforms the competition

More information

INSTALLATION AND INSTRUCTION MANUAL

INSTALLATION AND INSTRUCTION MANUAL INSTALLATION AND INSTRUCTION MANUAL SS650-013 013 SIREN LCS652-013 SIREN and Light Controller PLITSTR247 REV. F 12/9/13 NOTICE Due to continuous product improvements, we must reserve the right to change

More information

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. Mo 72 74 AUTO HEAT 70 Heat Pump &

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide

More information

Powerley Thermostat. Installation & Operation Guide

Powerley Thermostat. Installation & Operation Guide Powerley Thermostat Installation & Operation Guide i Welcome! After a quick installation, your new Powerley Thermostat will allow you to monitor and control your HVAC system from anywhere in the world.

More information

Meat Thermometer with Wireless Display model 01185

Meat Thermometer with Wireless Display model 01185 Instruction Manual Meat Thermometer with Wireless Display model 01185 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Features & Benefits... 3 Setup... 4 Using the Thermometer... 4-7 Troubleshooting...

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715 INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 715 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953

More information

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE

More information

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. Combustion Air system MODEL: CAS-4JR This product is designed for use with any natural gas or LP burning furnace, water heater, or boiler with a 24 VAC control system. It may be used with a residential

More information

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents: KT6 Temperature Chart Recorder Contents: Instructions, Alarm Relays & Started / Accessories Calibration, Warranty / Factory Service & Order Form Temperature Ranges (user selectable): Recorder Accuracy:

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

professional the the the

professional the the the professional the the the 2 This unit has many exciting features which are different from those found on standard PTAC models. The owner must be familiar with these features in order to fully understand

More information

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ. OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. AUTO Heat Pump & Heat Cool Dual Setpoint

More information

Model 405 AIRGARD Fume Hood Monitor

Model 405 AIRGARD Fume Hood Monitor INSTALLATION AND MAINTENANCE INSTRUCTIONS Model 405 AIRGARD Fume Hood Monitor A TSI Company Model 405 AIRGARD Fume Hood Monitor Specifications Instrument Dimensions Instrument Weight Shipping Weight Green

More information

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING Refrigeration and Air Conditioning Controls User s manual Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING Table of Contents Introduction p. 3 Configuring the host

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 7,891,572 INSTALLATION INSTRUCTIONS and OPERATING MANUAL Saves Fuel Features

More information

AFA 500 FUME HOOD ALARMS

AFA 500 FUME HOOD ALARMS AFA 500 FUME HOOD ALARMS Operating and Instruction Manual 19/7/03 Model AFA 500 Built-in or Remote sensor 2 Relay inputs 1 Relay output Com port Used for alarm indication and monitoring on Fume Cupboards

More information

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr. 1951 E. AIRPORT DRIVE Date: 8-20-2004 CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 OWNERS MANUAL CARBON MONOXIDE DETECTOR MODEL 452-201 REMOTE UNIT MODEL 452-201 OWNERS MANUAL Page 1 of 22 INTENTIONALLY

More information

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

DIGITAL STEEL FIRE & SECURITY

DIGITAL STEEL FIRE & SECURITY Models 2111-2115 DIGITAL STEEL FIRE & SECURITY Read this manual carefully and never store it inside the safe! Digital Steel Fire & Security Safe Models 2111-2115 PACKAGE CONTENTS 1 Digital Steel Fire &

More information