1 Temperature controller type KTR96EX PTB 97 ATEX 1031 X March 1999 thuba Ltd. CH-4015 Basle Telefon Telefax Headoffice@thuba.com
2 Manual PTB 97 ATEX 1031 X 2 Temperature Controller Type KTR96EX Target group: Experienced electrical technicians as defined by ElexV, and properly instructed personnel. Contents: 1. Safety instructions 2. Conformity with standards 3. Technical data 4. Installation 5. Maintenance 1. Safety instructions Temperature controller Type KTR96EX is not suitable for duty in Zone 0. Do not leave this Instruction Manual or other objects in the temperature controller s enclosure during operation. Use the temperature controller only in undamaged and clean condition, and only for the purpose for which it is intended. If the temperature controller is assembled incorrectly, the minimum protection classification of IP 54 according to EN :1991 will no longer be assured. Do not make any changes to the temperature controller other than those specifically mentioned in this Instruction Manual. When doing any work on the temperature controller, be sure to observe the national safety and accident prevention codes as well as the safety instructions in this Instruction Manual, which are stated in italics like this paragraph!
3 Manual PTB 97 ATEX 1031 X 3 2. Conformity with standards The temperature controller Type KTR96EX satisfies the requirements of EN : 1992 and EN :1994 and EN : It was developed, manufactured and tested in accordance with state-of-the-art engineering practice and EN Technical data Explosion protection EEx d e IIC T6 or EEx d e IIC T6 or T5 EC type testing certificate PTB 97 ATEX 1031X Enclosure material aluminium, stainless steel, carbon steel or polyester, depending on the version Rated voltage max. 400 V Nominal core cross-section 2.5 mm² Enclosure protection type IP 54 Admissible ambient temperature -20 C to +80 C, depending on current loading and version Enclosure dimensions 560 x 120 x 90 mm (L x W x D) or smaller
4 Manual PTB 97 ATEX 1031 X 4 KTR96EX Temperature Range No. Sensor Max. sensor temperature C C C C C C C C C C C C C C C C C C C C C C C C C C C C Marking 0102 II 2 G 4. Installation For installation/operation, observe the rules of ElexV and the Equipment Safety Law as well as the generally accepted rules of engineering practice (EN ) and this Instruction Manual. Any manipulation or recalibration of thermostats must be carried out in the deenergized state only.
5 Manual PTB 97 ATEX 1031 X 5 1 t 2 3 Figure 1: Connection diagram Terminal 1: input phase Terminal 2: output phase to heater Terminal 3: output phase to cooler Temperature controller Type KTR96EX is used within explosionhazard zones for controlling the operating temperature of resistance heaters. The temperature controller is designed for rigid mounting only, and should be used only for temperature control duty unrelated to safety aspects. A separate cable entry is provided for each temperature sensor and for each switching circuit. Only the cable entries provided for the respective switching circuits should be used for those circuits. The temperature sensors must be installed in such a way that their geometry (and therefore their volume) is not changed in any respect. No metal clips should be used for mounting, because they could deform the sensors when tightened. It is therefore recommended that glassfibre adhesive tape be used. The capillary tube should be installed so that it is protected; it is absolutely necessary to observe the minimum bending radius of 10 mm. Bending the capillary tube more than once can produce hairline cracks and should be avoided. Make the electrical connection as shown in Figure 1. Be very careful not to mix up the heater connection and the cooler connection. Prior to initial start-up, check to make sure that the connections are made up correctly. Then carry out a functional check, which must be duly recorded.
6 Manual PTB 97 ATEX 1031 X 6 Failure to observe the above figures or inadvertent interchanging of contacts can be dangerous! Because of their starting current, self-limiting heating cables should never be switched on or off directly by a thermostat! If the capillary tube is exposed to the same temperature as the sensor, differences will arise between the setpoint and actual temperatures. As the medium in the capillary tube heats up, it acts as an additional thermal sensor. The resulting error can amount to about 1.5 Kelvin per meter and 10 Kelvin temperature difference. Depending on the configuration, alter the capillary tube arrangement or, in the case of minor discrepancies, readjust as shown in Figure 2. The maximum admissible ambient temperature, which depends on the temperature class and the maximum current loading, is shown in the following table. Max. ambient temperature 40 C 60 C 75 C 80 C for temperature T6 T5 T6 T5 T6 T5 T5 class rated current [A] The figures given for temperature class T5 apply only if the rating plate marking clearly states class T5. Select the cross-section for the connecting cable as a function of the rated current. 5. Maintenance The provisions of ElexV 9, ElexV 13, and EN applicable to maintenance/overhaul/testing must be observed. When performing maintenance work, pay special attention to checking those parts that govern the equipment s type of protection.
Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax
Immersion heating type FL65.. PTB 97 ATEX 1027 X March 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax +41 061 307 80 10 Headoffice@thuba.com www.thuba.com Manual PTB 97 ATEX 1027 X 2 Immersion
More informationImmersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax
Immersion heating type IN 16.. PTB 99 ATEX 1009 U May 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax + 41 061 307 80 00 headoffice@thuba.com www.thuba.com Manual PTB 99 ATEX 1009U 2 Immersion
More informationJunction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999
Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX 3116 March 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax +41 061 307 80 10 Headoffice@thuba.com www.thuba.com
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationPEPPERL+FUCHS GmbH
Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationOperating Manual Distribution box
Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution
More informationTechnical Data. Dimensions
0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationFlammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2
Flammable gases Detectors Model DAX 03F DAX 03F- C DAX 03F- H Note for installation, use and maintenance Version 1.2 Introduction This handbook must be read carefully by any person who has or will have
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationEx Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder
Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder Load Systems International 2666 Boul du Park-Technologique Québec QC G1P 4S6 Canada www.loadsystems.com
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationExplosion-protected actuator Page 259 of 292
Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationPerformance Data. curus Component Recognized; File No. E IP 20
TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 8 mm
0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationDocumentation. Parallel Heating Cable. Type: ELP
Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant
More informationHazardous Location Heaters. Thermostat INSTRUCTION MANUAL
Hazardous Location Heaters Thermostat INSTRUCTION MANUAL Rev. K 2018 nvent P/N 89115890 TABLE OF CONTENTS Warranty and Return Policy...2 Application...3 Control Accuracy...3 Technical Data...3 Design Data...3
More informationINSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER
INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions
More informationDM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex
DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,
More informationOperating instructions Safety-monitoring module SRB 302X3. 1 About this document
1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for
More informationGas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.
Data sheet testo 317-2 / testo 316-1 / testo 316-2 / testo gas detector / testo 316-EX Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C
More informationGas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex
Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH4 C3H8 H2 Gas leak testing Over and over again, devastating explosions and fires are caused
More informationControl Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW
1 212 Double thermostat Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW RAZ-TW... 2-position control thermostat and thermal reset limit thermostat with singlepole
More informationTemperature Sensor TRG Original Installation Instructions English
Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationPROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO
PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2
More informationTC-5231 Series, TC-5232, & TC-5241 Series
TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air
More informationManual for QX0201 Push Button
Manual for QX0201 Push Button Purpose of this Instruction Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationIECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,
More informationSinus Jevi (Explosion-Proof) Condens Heaters
Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important
More informationWe measure it. testo 316-Ex CH 4 testo 316-1
Gas leak detectors testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C 3 H 2 Gas leak testing Over and over again, devastating explosions and fires are caused by leaky gas pipelines.
More informationExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems
HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and
More informationDesign and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators
Design and manufacture of agitators since 94 Top-entry agitators CONTENTS Page - Introduction - Precautions prior to start-up 4 - Safety recommendations 6.. Protection against the risk of explosion 6..
More informationPerformance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE
763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP
More informationInstallation guide 864 MTT Multi Thermo sensor Thermometer
Installation guide 864 MTT Multi Thermo sensor Thermometer April 2010 Part no. 4416.234 Revision 3 Honeywell Enraf PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail
More informationGas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.
Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C 3 H 2 Gas leak testing Over and over again, devastating explosions and fires are caused
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationContinuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3
Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G Operator s Manual 42/24-13 EN Rev. 3 Table of Contents Page Preface 3 General Safety Information 4 Special Safety Instructions
More informationGenie Heated Regulator Installation & Operation Instructions
Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737
More informationF17W44_MFB_F_EN INSTALLATION INSTRUCTIONS
F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS Contents Page User instructions 3-5 General 3 Fan installation 3-4 Maintenance 3 Electrical installation 5 Troubleshooting 5 Technical description 6-8 General
More informationEasy installation Certified for zones 1 and 21 High IP degree of protection
Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationStripping machine AI 01
Translation of the original operation manual Stripping machine AI 01 EN Operation manual Before putting the machine into operation, read the operation manual! Keep manual for future use. Fabrication number
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationUncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems for Use in Hazardous Locations - Directive
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationUser manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc
User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable
More informationPOINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001
POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationFrost Units for air temperature monitoring
284 284P0 Frost Units for air temperature monitoring QAF8... Robust aluminium die-cast housing Responds to temperature change sensed over any 30 cm length of capillary Small switching differential Good
More informationFE1 Explosion-Proof Electric Air Heaters
Explosion-Proof Electric Air Heaters The heater core assembly is contained in a sturdy, epoxy-coated, 14-gauge steel cabinet which also carries the motor and fan assembly. Adjustable louvers allow directional
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationTechnology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design
Technology Metal drum heater design Drum H eaters Isopad offers a range of drum and base heaters that provide a reliable way to reduce viscosity, protect stored product from frost and enable product removal.
More informationFlameproof Manual Call Points
Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....
More informationFirst Trace Heating Product Details
First Trace Heating Product Details and specifying guide Contents 2 4 6 9 9 10 Refrigeration Safe Trace Product Diagrams 11 Components www.first-traceheating.co.uk Introduction Specification Maximum Exposure
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationSurvey of electrical equipment installed in hazardous areas on tankers
(June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationRopox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /
Ropox Bathtub PDF 6128 / 08.01.2019 User Manual & Mounting Instructions Keep this manual with the product at all times! Contents... 1 Contents... 2 Presale information... 4 General product information...
More informationQ382A,B Pilot Burners
Q382A,B Pilot Burners INSTALLATION INSTRUCTIONS APPLICATION The Q382A,B Pilot Burners provide main burner ignition for natural and LP gas-fired equipment. The design makes them ideal for use with any millivolt
More informationQAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products
1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On
More informationFrost Protection Thermostat
1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching
More informationInstructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes
Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationConductivity Electrode LRG Original Installation Instructions English
Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards
More informationRosemount 752 Fieldbus Remote Indicator
Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,
More informationCO warning instruments and gas spillage detectors
CO warning instruments and gas spillage detectors For safety & service testo 315-1 testo 315-2 CO testo 317-3 testo 317-1 testo 315-1 Versatile CO measurement For safety and service testo 315-1 CO warning
More informationAdvance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules
Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules Operator s Manual 42/24-12 EN Rev. 4 Contents Page Preface 4 Safety Information General
More informationPROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC
PROCESS AUTOMATION Instruction manual Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC With regard to the supply of products, the current issue of the following document is applicable: The General
More informationSTARBOX - CONDENSER UNITS
EN STARBOX - CONDENSER UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Table of Contents 1. General Information 1 2. Handling and Storage.. 1 3. Installation. 1 4. Electrical Connections.. 4
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationFINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,
FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A
More informationOperating instructions Mini Jet Ionisator. Air Line V01
Operating instructions Mini Jet Ionisator Operating instructions Mini Jet Ionisator Air Line V01 Types: Mini Jet Ionisator Keep in a safe place for future reference! Contents 1. Notes on operating instructions
More informationDocumentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q
Documentation Glass -/quartz insulated Heating Cable Factory terminated Type: ELK-H, -HS, -Q ELW-H, -HS, -Q 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of
More informationMultipoint temperature sensor
Multipoint temperature sensor ATEX e / t for use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel B 903530.0.0
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationMatters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli
Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas Wang Qiaoli Nanyang Explosion Protected Electrical Apparatus Research Institute wqliii@163.com Keywords: hazardous
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationTranslation of the assembly instructions with operating instructions and technical appendix
BA Ex-SBU Switch box type SBU-x(1,2,3)x Translation of the assembly instructions with operating instructions and technical appendix In accordance with EU ATEX Directive 2014/32/EU In accordance with EU
More informationOPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER
OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER 1 1.0 GENERAL 1.1 All work should be carried out by suitable qualified personnel. 1.2 Heaters must be handled
More informationThermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597
1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole
More informationOperating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA
Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4
More informationINSTALLATION FB T: +44 (0) F: +44 (0) E: W:
INSTALLATION FB 1 Contents User instructions General Fan installation Maintenance Electrical installation Troubleshooting Technical description General Classification Technical specification Manufacturer
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More information