1 COLD / HOT CONTROL AKOCam The new generation of solutions for cold room stores AKOCAM The new generation of cold room solutions CAMCtrl Control Control CAMRegis Register Datalogger CAMAlarm Alarm Alarm CAMCombi Integrated solutions Integrated solutions A family of products to perform all the necessary functions: regulating the temperature, recording its behaviour or triggering the locked in person alarm, all locally or with remote monitoring. With the new family of advanced products, you will have a complete range to fulfil all the functions demanded in cold rooms, with the advantage of sharing design and beauty, both if you wish to install the different units independently or together. For its AKOCam range, AKO has created an intuitive fast menu system, with which the cooler will feel more at home. The parameters have been classified by name and grouped into functions, and the browsing has been designed in line with the trends of mobile phones and remote controls, thus allowing fast assimilation of the functions. CAMCtrl The new generation of controllers for cold room stores Designed for regulating the temperature in cold rooms more efficiently, they comprise several models, both for hot and cold room stores, with or without printer. CAMRegis The new generation of registers. The CAMRegis solutions have been designed to collect, register and print out the temperature and moisture in cold room stores. They offer information display and print out of the data stored by the equipment in the monitoring system with RS485 communication. CAMAlarm The new generation of alarms for people locked in the store This family of alarms is designed for cold room stores working at negative temperatures or with a controlled atmosphere, optically and acoustically signalling if there is someone trapped. They also have RS485 communication for connection to a monitoring system and relay output for connection to the GSM alarm system. Designed under EN European regulations. CAMCombi The most complete solution for cold room stores This family of controllers with registers and alarm appears from the CAMCtrl, CAMRegis and CAMAlarm series. It comprises different models that combine the best of each series. An intelligent solution that integrates all the necessary electronics of a cold room store in a single unit. 10
2 CAMCtrl 1 relay control, from -50ºC to +150ºC NTC or PTC probe programme-selectable Programmable for cold and hot. Display and control with decimal point. Wall mounting. Fixing holes adapted to universal embedding box. Parameter protection by password. Indication in ºC or ºF Application: Industrial and commercial cold, cold rooms, incubators, industrial warehouses, etc. With NTC probe, temperature range from -50.0ºC to +99.9ºC With PTC probe, temperature range from -50.0ºC to +150ºC Display 3 Digits (ºC/ºF) Resolution 0.1 ºC Box dimensions 171 x 94 x 42 mm Control relay SPST 16A, 250V, cosϕ= 1 Power supply 230V~ ±10%,50/60 Hz AKO Controller 230V~, 1 SPST relay, 1 NTC probe included Units CAMCtrl 3 relay control, from -50ºC to +100ºC Defrost by electric heat, air or hot gas bypass. Programmable defrost by regulating the compressor, resistances (or hot gas bypass) and fans. With a 2nd optional probe, it enables defrost by temperature. Password enabled for entering the programming. Indication in ºC or ºF selectable by programme and probe calibration. Application: Industrial and commercial cold, cold room stores, etc. Display 3 Digits (ºC/ºF) Resolution 0.1 ºC Box dimensions 171 x 94 x 42 mm Digital input for door contact. Fan relay SPST 6A, 250V, cosϕ = 1 Defrost relay SPDT 8A, 250V, cosϕ = 1 Power supply 230V~ ±10%,50/60 Hz AKO Controller 230V~,1 SPST relay,1 NTC probe included Units 11
3 COLD / HOT CONTROL CAMCtrl 4 relay control, from -50ºC to +100ºC Configurable auxiliary relay Defrost by electric heat, air or hot gas bypass, programmable by regulating the compressor, resistances (or hot gas bypass) and fans. With a 2nd optional probe, it enables defrost by temperature. Auxiliary relay configurable for indicating alarms, defrost 2nd evaporator or solenoid control. Possible stop for pump down. Input for independent temperature probe or defrost control in 2nd evaporator. Digital input for door contact. Application: Industrial and commercial cold, cold room stores, etc. Display 3 Digits (ºC/ºF) Resolution 0.1ºC Box dimensions 171 x 94 x 42 mm Fan relay SPST 6A, 250V, cosϕ = 1 Defrost relay SPDT 8A, 250V, cosϕ = 1 Auxiliary relay SPST 6A, 250V, cosϕ = 1 Power supply 230V~ ±10%,50/60 Hz AKO Controller 230V~, 4 relays, 1 NTC probe included Units CAMCtrl 3 relay control, from -50ºC to +150ºC Controller with built-in register for cold or hot Graphic screen with customisable information. Programming assistant and onscreen help. Input for NTC/PTC probe programme-configurable. Internal memory up to one year for temperature register, with a battery for autonomy up to 24 hours. Designed under EN European standard. Wall and panel mounting. RS485 communication, integrated ModBus protocol. Application: Industrial and commercial cold, cold rooms and cabinets, industrial machinery, ovens, etc. With NTC probe, temperature range from -50.0ºC to +99.9ºC With PTC probe, temperature range from -50.0ºC to +150ºC Resolution 0.1 ºC AKO Di1 Di2 LIGHT COOL 230V~ Panel cut-out dimensions 214 x 214 mm Light relay SPST 16A, 250V, cosϕ = 1 Alarm relay SPDT 8A, 250V, cosϕ = 1 2 configurable digital inputs AKO CAMCtrl-3, 230V~ Unit AKO CAMCtrl-3 + printer, 100 to 240V~ Unit 12
4 CAMCtrl 6 relay control, from -50ºC to +100ºC Controller with built-in register Graphic screen with customisable information. Programming assistant and onscreen help. Auxiliary relay configurable for 2nd evaporator defrost or stop for pump down. Input for independent temperature probe or defrost control in 2nd evaporator. Internal memory up to one year for temperature register, with a battery for autonomy up to 24 hours. Designed under EN European standard. Wall and panel mounting. Integrated RS485 communication. ModBus protocol. Application: Industrial and commercial cold, cold rooms and cabinets, etc. AKO Fan relay SPST 8A, 250V, cosϕ= 1 Defrost relay SPDT 16A, 250V, cosϕ = 1 Auxiliary relay SPST 16A, 250V, cosϕ= 1 Light relay SPST 16A, 250V, cosϕ = 1 Alarm relay SPDT 8A, 250V, cosϕ = 1 2 configurable digital inputs Di1 Di ROST FAN LIGHT AUX COOL 230V~ AKO CAMCtrl-6, 230V~ Unit AKO CAMCtrl-6 + printer, 100 to 240V~ Unit CAMCtrl Control board with built-in register Display and distributed control Display of information on graphic screen. Programming assistant and on-screen help. Autonomous control board, with internal memory up to one year for registering temperatures, with battery for autonomy up to 24 hours. Designed under EN European standard. Auxiliary relay configurable for 2nd evaporator defrost or pump down. Input for independent temperature probe or defrost control in 2nd evaporator. Wall and panel mounting. Integrated RS485 communication. ModBus protocol. Application: Industrial and commercial cold, cold rooms and cabinets, etc. Resolution 0.1 ºC / Accuracy ±1 ºC Display size 230 x 230 x 90 mm Di1 Di2 AKO ROST FAN LIGHT AUX COOL 230V~ RS485 communication between units Fan relay SPST 8A, 250V, cosϕ= 1 Defrost relay SPDT 16A, 250V, cosϕ = 1 Auxiliary relay SPST 16A, 250V, cosϕ= 1 Light relay SPST 16A, 250V, cosϕ = 1 Alarm relay SPDT 8A, 250V, cosϕ = 1 2 configurable digital inputs AKO CAMCtrl-6S, 230V~ unit AKO CAMCtrl-6S + printer, 100 to 240V~ unit AKO CAMCtrl-6S Split Plate, 230V unit 13
5 COLD / HOT CONTROL CAMRegis Registers of temperature and moisture with 5 inputs Input for NTC probes, Pt100, thermocouples J, K and 4-20mA Graphic screen with customisable information. Display and printout by graphs or value tables. Very suitable for registering the temperature or moisture in cold room stores and in applications where permanent display and registering is necessary. Memory to register data up to 1 year, with internal battery for autonomy up to 48 hours. Designed under EN European standard. Relay output for alarm signalling. Remote printout through printers on other units. Wall and panel mounting. Integrated RS485 communication. ModBus protocol. Application: Industrial and commercial cold, processing industry, etc. Temperature range depending on probe model ºC to +1000ºC Range 4-20mA -999 to S4 S5 +10V 60mA max MINIMUM 230V~ MAXIMUM Resolution 0.1 / Accuracy ±1 ºC Input accuracy 4-20mA ±0.2mA Alarm relays 2 SPDT 8A, 250V, cosϕ= 1 Autonomy 48 hours AKO Register without printer 100 to 240V~ + 5 NTC probes Unit AKO Register with printer 100 to 240V~ + 5 NTC probes Unit AKO Printer, 100 to 240V~ Unit CAMRegis Registers of temperature and moisture with 10 inputs Inputs for NTC probes, Pt1000, thermocouples J, K and 4-20mA. Graphic screen with customisable information. Display and printout by graphs or value tables. Very suitable for registering the temperature or moisture in cold room stores and in applications where permanent display and registering is necessary. Memory to register data up to 1 year, with internal battery for autonomy up to 48 hours. Designed under EN European standard. Relay output for alarm signalling. Remote printout through printers on other units. Wall and panel mounting. Integrated RS485 communication. ModBus protocol. Application: Industrial and commercial cold, processing industry, etc. Temperature range depending on probe model ºC to +1000ºC Range 4-20mA -999 to +999 S4 S5 S6 S7 S8 S V MINIMUM 60mA max 230V~ MAXIMUM Resolution 0.1 / Accuracy ±1ºC Input accuracy 4-20mA ±0.2mA Alarm relays 2 SPDT 8A, 250V, cosϕ= 1 Autonomy 48 hours AKO Register without printer 100 to 240V~ + 5 NTC probes Unit AKO Register with printer 100 to 240V~ + 5 NTC probes Unit AKO Printer. 100 to 240V~ Unit 14
6 CAMAlarm Alarm for cold room stores, with output for 1 light Optical and acoustic alarm This family of alarms is designed for cold room stores that work at negative temperatures or with controlled atmospheres, indicating optically and acoustically if anyone is trapped. All units have a relay output for connection to GSM alarm system. 230V~ AKO Optical and acoustic alarm 1 output relay for remote alarm indication Wall and panel mounting. Autonomy over 1 hour Alarm dimensions 230 x 230 x 90 mm Light dimensions 171 x 94 x 42 mm Power supply 230V~ ±10%.50/60 Hz AKO Alarm, with output for 1 light (included) Units AKO Spare power supply Unit CAMAlarm Alarm for cold room stores. EN European standard Up to 4 lights to indicate up to 4 doors and pushbuttons This family of alarms is designed for cold room stores working at negative temperatures or with a controlled atmosphere, optically and acoustically signalling if there is someone trapped. All units have a relay output for connection to GSM alarm system. This model is designed under EN European standard and is provided with RS485 communication for connection to a monitoring system. 230V~ 1 AKO Optical and acoustic alarm 1 output relay for remote alarm indication Battery charge indication Autonomy over 10 hours Wall and panel mounting Alarm dimensions 230 x 230 x 90 mm Light dimensions 171 x 94 x 42 mm Power supply 230V~ ±10%.50/60 Hz AKO Alarm, with output for 1 light (included) Units AKO Alarm, with output for 4 lights (1 included) Units AKO Spare power supply for AKO Unit AKO Spare power supply for AKO Unit 15
7 COLD / HOT CONTROL CAMCombi 6-relay control, from -50ºC to +100ºC, with alarm for cold room store Controller with built-in alarm and register. This family of controllers with registers and alarm appears from the CAMCtrl, CAMRegis and CAMAlarm series. Display of information on graphic screen. Person locked in alarm in room with output for 4 lights and autonomy of 10 hours. Identification of the alarm signal to know which pushbutton has triggered the alarm. Wall and panel mounting. Interior space for up to 2 contactors. Integrated RS485 communication. ModBus protocol Resolution 0.1ºC Box dimensions 346 x 230 x 111 mm 4 AKO Di1 Di2 ROST FAN LIGHT AUX COOL 230V~ Panel cut-out dimensions 330 x 214 mm Fan relays SPST 8A, 250V, cosϕ= 1 Defrost relay SPDT 16A, 250V, cosϕ = 1 Auxiliary relay SPST 16A, 250V, cosϕ = 1 Light relay SPST 16A, 250V, cosϕ= 1 Alarm relay SPDT 8A, 250V, cosϕ= 1 1 output relay for remote alarm signalling AKO CAMCtrl-6 + alarm, 230V~ (1 light included) Unit AKO Printer, 100 to 240V~ Unit CAMCombi 6-relay Split control, from -50ºC to +100ºC, with alarm for cold room store Display with alarm and control board with built-in register. This family of controllers with registers and alarm appears from the CAMCtrl, CAMRegis and CAMAlarm series. Display of information on graphic screen. Autonomous control board, with internal memory up to one year for registering the temperature. Person locked in alarm in room with output for 4 lights and autonomy of 10 hours. Identification of the alarm signal to know which pushbutton has triggered the alarm. Wall and panel mounting. Interior space for up to 2 contactors. Integrated RS485 communication. ModBus protocol Resolution 0.1 ºC / Accuracy ±1 ºC Box dimensions 346 x 230 x 90 mm 4 AKO Di1 Compressor relay SPST 16A, 250V, cosϕ= 1 Fan relay SPST 8A, 250V, cosϕ= 1 Defrost relay SPDT 16A, 250V, cosϕ= 1 Auxiliary relay SPST 16A, 250V, cosϕ= 1 Light relay SPST 16A, 250V, cosϕ= 1 Alarm relay SPDT 8A, 250V, cosϕ= 1 1 output relay for remote alarm signalling AKO CAMCtrl-6S + alarm, 230V~ (1 light included) Unit AKO CAMCtrl-6S Split Plate, 230V~ Unit AKO Printer, 100 to 240V~ Unit Di ROST FAN LIGHT AUX COOL 230V~ 16
AKOSoft.
Catalogue 2013 AKOSoft www.akotrace.com AKO www.ako.com AKOSoft AKO the leading company in comprehensive Regulation and Control of Industrial and Commercial Refrigerated facilities in the Refrigeration,
More informationThermometers and temperature controllers
D144H002 Ed.07 GB Thermometers and temperature controllers User Manual Contents AKO Electromecánica thanks and congratulates you for purchasing our product, in whose development and manufacture the most
More informationIN NOURISHING SECURITY.
HOJA TÉCNICA 1400H171 Edición 02 (01 de 08) Electronic controllers for refrigeration R NEW leads the way Furthermore to control the CCPs Critical Control Points, in the HACCP Hazard Analysis Critical Control
More informationCATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION
CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN
More informationPROPlus Basic / CAMCtrl Basic
1564H502 Ed.05 GB PROPlus Basic / CAMCtrl Basic User Manual AKO-15645 AKO-15646 AKO-15648 AKO-15626 AKO-15627 Index 1.- Presentation...3 1.1.- Versions...3 1.2.- Maintenance...3 1.3.- Cautions...3 2.-
More informationPOCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS
POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More information5-stage compressor racks + 2 converter outputs
GB 1454H502 Ed.02 AKO-14545 AKO-14545-C 5-stage compressor racks + 2 converter outputs User Manual Contents Page 1.- Precautions...3 2.- Versions and part numbers...3 3.- Description...3 3.1.- Keypad functions...3
More informationExternal Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm
External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white
More informationPROPlus 3PH BASIC Electronic Panel
GB AKO-1569x AKO-1569x-EVC PROPlus 3PH BASIC Electronic Panel User Manual Index Page 1.- Presentation...3 1.1.- Maintenance...3 1.2.- Precauciones...3 2.- Versions and references...3 3.- Installation...4
More informationLaboratory Refrigerator/Deep Freezer TC 802
External Dimension: B = 600 mm D = 615 mm H = 2000 mm Inside Dimension: Useful space on top Useful space at the bottom B = 440 mm B = 431 mm D = 435 mm D = 435 mm H = 1105 mm H = 597 mm Capacity: 254 l
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationTemperature and moisture controller for cold rooms
GB AKO-6624 Temperature and moisture controller for cold rooms User Manual Page Index Warnings...3 Wiring...3 Maintenance...3 Description...4 Installation...6 Initial configuration...7 Operation...9 Configuration...22
More informationElectronic data logger, 10 channel, as per European standard EN 12830
HOJA TÉCNICA 1572H1 Edición 03 (01 de 08) Electronic logger, channel, as per European standard EN 12830 R www.ako.es CONTENT 1- INTRODUCTION 2- INSTALLATION 2.1- Accessories 2.2- Installation of the logger
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationPlasma Freezer with air circulation TC 516 acc. to DIN 58375
These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm
More informationPlatelet bags constant shaking for long periods of time.
Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET
More informationTemperature - Humidity - Pressure
TEMPERATURE-HUMIDITY-PRESSURE INDICATORS XA100C Configurable digital indicators for temperature, humidity or pressure C: 32x74mm DC- TBXABDA100 XA100C -0C0PU PTC NTC inputs 12V DC- TBXABCA100 XA100C -0C0TU
More informationRemote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used
employs a variety of advanced features that enable the controller to monitor and control the environment inside a freezer with a high level of precision. Liquid Nitrogen Level Measurement uses a differential
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationDIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)
Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read
More informationMeasuring Recording Online Monitoring Regulation Alarming
Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical
More informationEMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR
EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust
More informationExternal Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C
External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality
More informationBottle cooler controllers Solutions for static, ventilated and open coolers
Bottle cooler controllers Solutions for static, ventilated and open coolers XRB Bottle cooler controllers The XRB series is the high-efficiency range of products available in 2 versions, standard and advanced
More informationTemperature and moisture controller for cold room store
GB 1662H402 Ed.01 AKO-16624 Temperature and moisture controller for cold room store User Manual Index Page Warnings...3 Wiring...3 Maintenance...3 Description...4 Installation...6 Initial configuration...7
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationDixell Installing and Operating Instructions release 7.0
XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1
More informationAdvanced temperature controller for cold rooms
GB 1652H4A02 Ed.03 AKO-16524A Advanced temperature controller for cold rooms User manual Index Page Presentation...3 Warnings...3 Maintenance...3 Description...4 Installation...6 Wiring...7 Installation
More informationECH 985. Electronic controller for heat pumps used in residential hot water application
ECH 985 Electronic controller for heat pumps used in residential hot water application Introduction General Description ECH 985 is a heat pump for the following kinds of applications: water-water water-air
More informationDOUBLE DOOR FREEZER.
DOUBLE DOOR FREEZER www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. UPRIGHT FREEZER DOUBLE DOOR LUFD-25-100 SERIES Labocon
More informationWH7016E Thermostat Product Manual
WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian 1 Installation opening size: 2 Wiring diagram: 1 2 3L
More informationRefrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301
Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control
More informationLabel Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature
EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with
More informationTECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB
Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7
More informationD3 Wireless temperature alarm & monitoring system family. tek-troniks
D3 Wireless temperature alarm & monitoring system family tek-troniks D3 Wireless temperature alarm & monitoring system family No server or dedicated pc No ongoing cloud costs or licencing fees. Fully web
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationCTT8 TEMPERATURE MONITOR DEVICE
INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible
More informationN1540 Process Indicator
N1540 Process Indicator UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V2.0x PRESENTATION N1540 is a quite versatile process indicator. With a wide list of input types - thermocouples, thermo-resistance, voltage
More informationSCAN20 Series Gas Detection Controller
SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationUniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser
Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis
More informationMO n : 12JMC rév A
CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES
More informationECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)
ECB-5070 General descriptions: This product has the function of current display and motor integrated, which can effectively avoid the various danger caused by the instability of current and voltage, to
More informationECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2
TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2 1. Product Overview 1.1 Display Large LCD display for measured values and status Time Alarm (will stay lit until Upper / Lower limit value (except for TN2) the
More informationEL-USB-1-LCD Temperature Data Logger with LCD
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 EL-USB-1-LCD Temperature Data Logger with LCD Visit us at www.testequipmentdepot.com ORDERING INFORMATION Standard Data
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationportable gas analyser
www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More information973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS
Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationER52 - Evaporator Controller
ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They
More informationXWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,
More informationXWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationBIOMEDICAL REFRIGERATORS
BIOMEDICAL REFRIGERATORS U LT R A L O W F R E E Z E R S - L A B O R AT O R Y, P H A R M A C E U T I C A L A N D M E D I CA L R E F R I G E R AT I O N ARCTIKO CONTROLLER At Arctiko we have the customer
More informationModular Standard HP Chiller 1/4 screw compressor with Carel driver
Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?
More informationEL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD
High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,
More informationBIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION
BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION ARCTIKO CONTROLLER At Arctiko we have the customer in mind when engineering new technologies. With the large
More informationAnalog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation
Gas Detection Control Panel Analog and digital controller 4 or 8 lines / 6 to detectors max Highly versatile controller Cost savings on wiring installation Certifications The The Fixed Fixed Gas Gas Detection
More informationMX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel
Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller SIL reliability Fixed The Fixed Gas Gas Detection Detection Experts People www.oldhamgas.com
More informationOperating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationGas Leak Detection Alarm
GB 5572H402 Ed.02 AKO-55624 AKO-55724 Leak Detection Alarm User Manual dex Page Versions and references...3 Equipment description...4 Warnings...5 Maintenance...5 stallation...5 Alarm Station...6 Wiring...7
More informationFully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Prüftechnik ACS 600, 601, 650 Air conditioning service units from Bosch NEW! Ñ ACS 600 even the entry model is fully
More informationMultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price
MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationSCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview
Micro SCM Streaming Current Monitor A Watts Water Technologies Company Instrument Overview The instrument consists of the Analyzer and the SCM sensor. Analyzer The Analyzer The monitor has a built in graphic
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationPROCool Electronic Panel
GB 1763H232 Ed.01 AKO-17632 AKO-17633 AKO-17634 AKO-17635 AKO-17636 AKO-17637 AKO-17520 AKO-17521 PROCool Electronic Panel User manual Index Page 1.- Presentation...3 1.1.- Maintenance...3 1.2.- Precautions...3
More informationOptimize your HVAC/R application with the right Danfoss components
ADAP-KOOL Selection Guide Optimize your HVAC/R application with the right Danfoss components One- Stop-Shop for flexible control solutions Engineering Tomorrow s Food Retail Solutions Enterprise Manager
More information3500/61E & 3500/67E Temperature Monitor
3500/61E & 3500/67E Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors
More informationIPC108D - IPC108E (V.2.0)
IPC108D - IPC108E (V.2.0) APPLICATION GUIDE INDEX 1. IMPORTANT RECOMMENDATIONS 6 1.1 PRODUCT DISPOSAL (WEEE) 7 2. GENERALITIES 8 3. AVAILABLE APPLICATION CONFIGURATIONS 8 3.1 MAIN FUNCTIONS 9 4. SUPERVISION
More informationMX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation
Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller Cost savings on wiring installation The Fixed Gas Detection People www.oldhamgas.com an
More informationportable gas analyser
www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.
More informationUser Manual Ichill 200 L/D (Firmware version 1.7)
User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationFCR 05, FCR 07. Power factor correction controller. User and service manual
FCR 05, FCR 07 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction
More informationDew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510
Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured
More informationEC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:
EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationComfort System T-21-P Touchscreen Thermostat Installation Manual
Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationSpecification for On-Line UPS Battery Monitoring and Data Management System
1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the
More informationFCR05, FCR07. Power factor correction controller. User and service manual. version 3.4 (FW version 8.91 and newer)
FCR5, FCR7 Power factor correction controller User and service manual version 3.4 (FW version 8.91 and newer) Content 1. Safety instructions...3 9.1. Connection configuration (Con)...12 2. Packaging content...3
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
OEM Packaged Voltage Data Logger ORDERING INFORMATION Standard Data Logger (Data Logger only. EasyLog software available from ) EL-OEM-3 FEATURES PCB Mounted (2.54mm pitch, header sockets) 0-2.4 Volt d.c.
More informationIntelliPack : 800 Series
800 Series Models by Function Guide 800T Intelligent Transmitters 800A Intelligent Alarms 890M Math/Computation IntelliPack transmitter units convert sensor inputs to isolated process current or voltage
More informationInstallation Manual Tracker 221
Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing
More informationSmart Temp. ApolloP/n Installation Manual. Version 1.0
Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationST Wiring diagram. Product description. Standard temperature controller. Order number
ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationElectronic expansion valve controller
GB 1456H002 Ed.03 AKO-145601 Electronic expansion valve controller User Manual Index 1.- Introduction...3 2.- Versions and references...3 Compatibility...3 3.- Installation...4 Precautions...4 Maintenance...4
More information