1 Fire Safety, Fire Procedures and Three Schools Policy Date Originated December 2010 Issue Number 3 Last Revision Date October 2013 Date of Review by Governors 4 April 2014 This policy is endorsed by This policy is owned by This policy is maintained by ISI Reference The Governors and the Heads Bursar Deputy Bursar A11 Page 1 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

2 PART ONE FIRE SAFETY INTRODUCTION Our priority is to minimise the risk to life and to reduce injury by maintaining the physical fire safety of the school, in ensuring that staff, pupils and visitors do not add to the fire risk and through safe evacuation of our buildings if a fire breaks out. The fire safety policy, procedures and risk assessments at Bedales schools are designed to help our community to respond calmly and effectively in the event that fire breaks out in one of our buildings. ROLE OF THE SCHOOL FIRE SAFETY MANAGER The Deputy Bursar (Facilities) is the designated School Fire Safety Manager, who is responsible for ensuring that: The fire safety policy is kept under regular review by Governors and the SMT. The fire safety policy is promulgated to the entire school community. Everyone in the school (including visitors and contractors) are given clear written instructions on where they should go in the event of fire. Records are kept of the fire induction training given to new staff and pupils. Procedures and arrangements for emergency evacuation are regularly tested and lessons absorbed. Fire risk assessments are regularly reviewed and updated. Fire prevention measures are meticulously followed. Fire procedures and risk assessments are reviewed on each occasion that a building is altered, extended or rebuilt, or when new buildings are acquired Records are kept of all fire practices, including night practice evacuations from boarding accommodation. Certificates for the installation and maintenance of fire-fighting systems and equipment are kept. Page 2 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

3 BEDALES EMERGENCY EVACUATION PROCEDURE All new staff and pupils, all contractors and visitors are shown the following notice: 1. If you discover a fire, break the glass in the nearest alarm point to set off the alarm or shout: Fire Fire Fire. Leave the building by the nearest exit. 2. If you are responsible for a class, make them leave quietly with you. No one should talk or run. Make your way to the nominated assembly point for the building you are in and as detailed on the map at Appendix One. 3. Do not take anything with you, and do not allow the pupils to take anything. Shut doors and windows behind you. 4. If you have a disabled pupil in your class, you should move him or her downstairs, using one of the special evacuation chairs if you are trained to do so, following the procedures outlined in his/ her Personal Emergency Egress Plan (PEEP). 5. The School Fire Safety Manager or his nominated deputy will investigate each alarm and will summon the Emergency Services if there is a real fire. 6. If the alarm is false and there is no fire, the school Fire Safety Manager or his nominated deputy will, once he or she is satisfied it is safe, give the all clear and staff and students will be allowed back into the building concerned. 7. Should there be a real fire, or there be other reason to do so, the School Fire Safety Manager or his nominated deputy will sound the whole school evacuation siren. On hearing this siren all staff and students are to make their way to the Whole School Assembly Point (the Astroturf Pitch) and line up as per diagram on page At the Whole School Assembly Point a register of all pupils and staff should be taken and anyone who is waiting to be evacuated from a designated refuge or who is missing should be reported immediately to the Managing Head of Bedales or to the Deputy Bursar (Facilities) who will inform the Fire Brigade accordingly. On no account should anyone return to any building until given permission by the Fire and Emergency Services. 9. All staff and students must remain at the Whole School Assembly Point until the all clear is given by either the Fire Brigade or the School Fire Safety Manager or his deputy. 10. After each fire practice the Fire Safety Officer will convene a short meeting to ensure that all procedures were followed correctly and to identify any lessons to be learned. Page 3 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

4 DUNHURST FIRE EVACUATION PROCEDURE 1. If you discover a fire then sound the automatic alarm, by breaking the glass covered switch (if the sensors have not already set the alarm off). Alert anyone nearby & then evacuate the building. Do not hesitate and do not attempt to tackle the fire yourself. 2. The fire alarm is a continuous sounding of a siren. If the alarm sounds you should vacate the buildings immediately, leading pupils and visitors in your care out in an orderly manner, and proceed to the Assembly Areas on the Playground. 3. The Deputy Head, or in their absence a Senior Colleague, will take charge of the Fire Assembly. The role of the staff is defined later. 4. When the alarm sounds teachers in charge of pupils should lead their class out in an orderly manner. Leave bags and coats, close doors, follow the designated route to the assembly point on the playgrounds, and do not re-enter any building. It is important the classes being taught away from the main building (for example PE) are able to be contacted by phone. Responsibility for informing such classes will be with Reception staff. 5. In the event of a real fire, when we may not be able to use the Playgrounds to assemble due to the proximity of the fire then the contingency procedure is to re-assemble on Cobb s Field with staff helping to supervise and register all pupils present. The instruction to do this will be given by the Person i/c of the Fire Assembly. However, if you cannot gain access to the playgrounds due to obvious smoke/fire in that area then staff should lead pupils immediately to the alternate Assembly point on Cobb s Field. 6. Designated teachers (see later) are to take charge of their assigned form group at the Assembly Areas, checking attendance against the fire list. The form lists and the daily fire list will be distributed by Reception staff. 7. Teachers without a form group, visitors, who must signed in at reception on entry to the school, and all support staff, will register with Reception staff or the Heads Secretary. 8. In the event of a real fire the School will take advice and direction from the Fire Brigade once they have been summoned. Page 4 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

5 9. No one is to leave the Assembly area or re-enter a building during the drill, unless asked to do so and nobody should re-enter a building under any circumstances during a real fire. 10. After each fire practice the Fire Safety Officer will convene a short meeting to ensure that all procedures were followed correctly and to identify any lessons to be learned. Page 5 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

6 DUNANNIE FIRE EVACUATION PROCEDURE All new staff and pupils, all contractors and visitors are shown the following notice: 1. If you discover a fire then sound the automatic alarm, by breaking the glass covered switch (if the sensors have not already set the alarm off). Alert anyone nearby and then evacuate the building. Do not hesitate and do not attempt to tackle the fire yourself. 2. The fire alarm is a continuous sounding of a siren. If the alarm sounds you should vacate the buildings immediately, leading pupils and visitors in your care out in an orderly manner, and proceed to the Orchard Assembly Area. 3. The Head of Dunannie, or in her absence the Senior Teacher, will take charge of the Fire Assembly. 4. When the alarm sounds teachers in charge of pupils should lead their class out in an orderly manner. Leave bags and coats, close doors, follow the designated route to the assembly point in the orchard and do not re-enter any building. It is important that the children being taught out of the classroom are brought to the orchard by their teachers. Appointed sweepers check designated areas of Dunannie to ensure they are clear. 5. In the event of a real fire, or incident, when we may not be able to cross the playground or use the orchard to assemble due to the proximity of the fire, then the contingency procedure is to re-assemble on the Dunhurst Sports Field with staff helping to supervise and register all pupils present. The instruction to do this will be given by the person in charge of the Fire Assembly. 6. At the Assembly point, class teachers take charge of their classes in the orchard, checking attendance against the fire list. The class lists and the daily fire list will be distributed by Reception. Pupils will form a single line and staff must ensure conduct is of a high standard and that the class is silent and listening to instructions. 7. Teachers without a class, visitors, who must have signed in at Reception on entry to the School, and all support staff, will register with Reception staff or the Heads Secretary. 8. In the event of a real fire the School will take advice and direction from the Fire Brigade once they have been summoned. 9. No one is to leave the orchard or re-enter a building during the drill, unless asked to do so and nobody should re-enter a building under any circumstances during a real fire. Page 6 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

7 10. After each fire practice the Fire Safety Officer will convene a short meeting to ensure that all procedures were followed correctly and to identify any lessons to be learned. Page 7 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

8 BRIEFING NEW STAFF AND PUPILS PART TWO FIRE SAFETY PROCEDURES All our new staff (teaching and non-teaching alike) and all new pupils, including EYFS pupils, are given a briefing on the school s emergency evacuation procedures on their first day at Bedales Schools. We show them where the emergency exits and escape routes are located, and walk with them to the outside assembly point. Fire action notices are displayed on the walls of all rooms and in all corridors, and we make certain that everyone knows what they look like, and where they should go on hearing the fire alarm. All new staff are shown how to activate the fire alarms if they see or smell a fire. The safe evacuation of everyone - staff and pupils alike, is our priority. Protecting property comes second. No one should attempt to fight a fire at the expense of their own, or anyone else s safety. We offer fire awareness INSET training, including the basic use of fire extinguishers, to all staff during their first term. We also offer regular refresher training. No one should attempt to use a fire extinguisher before he or she has been trained in its use. SUMMONING THE FIRE BRIGADE The School Office is manned between 8.30am and 5.00pm during weekdays in term-time and between 8.30am and 4.30pm during half terms and holidays apart from the Christmas and Easter closedowns. The master panel that shows the location of all the alarm call points on the networked alarm system in the school buildings is physically located in the Facilities office. The Facilities Office is always given advance warning of fire practices. If the alarm goes off for any other reason, the staff have standing instructions to summon the Fire and Emergency Service at once. One of the members of the Facilities Staff is on duty or on call 24 hours a day, 7 days a week, and 365 days a year, including public holidays. He/She has standing instructions to summon the Fire and Emergency Services if the alarms go off outside the hours that the Facilities Office is staffed, (unless warned of a planned fire practice). VISITORS AND CONTRACTORS All visitors and contractors are required to sign in at Reception, where they are issued with a visitor s badge, which should be worn at all times that they are on school property. They are made aware of the emergency evacuation notice (see above) and are shown the way to the assembly point. Page 8 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

9 When large numbers of visitors are at the school for open days, plays, concerts, exhibitions etc a brief announcement is made advising them of the location of the emergency exits that they should use in the event of the alarms sounding. DISABLED STAFF, PUPILS OR VISITORS We have a special one to one induction on fire safety for disabled pupils and their carers and for disabled members of staff or visitors. We have designated safe refuge points on every floor of every building, with signs advising of their location, (usually in a stair well). When the fire alarm is sounded, it is the responsibility of the carer of a disabled person to take him or her to the refuge point and activate the relevant PEEP. The teacher will ensure that the name of the disabled person and his or her carer, together with the location of their safe refuge point, are passed to the School Fire Safety Manager, the Bursar, or the Head of the relevant School as soon as he or she reaches the assembly point. It is the responsibility of the School Fire Safety Manager, the Bursar or the head of the relevant school to ensure that this information is passed as soon as possible to the Fire and Emergency Service, although it is the school s responsibility to ensure the safe evacuation of everyone. RESPONSIBILITIES OF TEACHING STAFF Teaching staff are responsible for escorting their pupils safely out of the building in silence and in an orderly fashion. They are responsible for conducting a head count on arrival at the assembly point, and for ensuring that the name of anyone who cannot be accounted for (and, if possible, their likely location) is passed immediately to the Head of the relevant School, the School Fire Safety Manager or to the Bursar. It is the responsibility of the Head of the Relevant School, the School Fire Safety Manager or the Bursar to ensure that this information is passed to the Fire and Emergency service as soon as they arrive. On no account should anyone return to a burning building. RESPONSIBILITIES OF FIRE MARSHALS We have at least one trained Fire Marshal in every building and boarding house. Fire Marshals are generally members of the non-teaching staff, such as Technicians, Matrons, Maintenance, Security and Administrative staff who do not have specific duties in the event of fire or other emergency for looking after pupils, (although members of the teaching staff may also opt to be trained as Fire Marshals). All Fire Marshals are competent persons who have been trained to provide safety assistance in the event of a fire. Fire Marshals receive regular refresher training. FIRE PRACTICES Page 9 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

10 We hold at least one fire practice every term at Bedales Schools. We also practice a night-time evacuation of the boarding houses every term. This combined with a programme of inducting new staff and pupils with emergency escape procedures and the presence of trained Fire Marshals in every building helps to ensure that the school can be safely evacuated in the event of a fire. FIRE PREVENTION MEASURES We have the following fire prevention measures in place at Bedales Schools: Escape Routes and Emergency Exits There are at least two escape routes from every part of all buildings Fire notices and evacuation signs are displayed in every room, corridor and stairwell. Fires extinguishers (of the appropriate type), smoke/heat detectors and fire hoses are located in every building in accordance with the recommendations of our professional advisors. They can be manually activated by breaking a glass panel, and are automatically activated when smoke/heat builds up. Smoke control systems are located in our boarding accommodation. All stairs, passages and emergency exits are illuminated by emergency lighting. Automatic door closers that are activated by the fire alarms are fitted in some buildings and on doors in or leading onto escape routes. The master panel for the alarm system is located in the Facilities Office and shows the location of a fire. It is fitted with an uninterrupted power supply (UPS) Alarms sound in all parts of the buildings. In the following areas they are supplemented by visual alarms (red flashing lights): Sound-proofed music practice rooms The swimming pool The DT workshop The Theatre Sports Hall Keeping fire routes and exits clear at all times. The Domestic Manager is responsible for unlocking the buildings in the morning, when he removes bolts, padlocks and security devices from all emergency exits, checks that escape routes are not obstructed and reports defects. Page 10 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

11 Testing all fire alarms weekly (and recording all tests and defects). This is the responsibility of the Facilities Operations Manager, who also arranges for an ISO9001 certified/bafe approved contractor to carry out: Monthly checks of fire doors, automatic door closures and emergency lights, Six monthly professional check on fire detection and warning equipment, An annual service of alarms, smoke detectors, emergency lights, sprinklers, smoke control systems and fire extinguishers and hoses. Records of all tests are kept in the Facilities office. Records kept that all displays in corridors, theatre scenery, stage curtains and props and gym crash mats are treated with fire retardant spray. Plans showing the location of fire hydrants, gas and electricity shut off points are displayed in fire proof glass fronted display boards next to the entrance of each building. The kitchen is fitted with heat alarms and 30 minute fire doors that close automatically when the fire alarms sound. Electrical Safety The School has current electrical test certificates for all its buildings. It uses NICEIC qualified Electrical Engineers to inspect and maintain its electrical installations all of which meet 17 th Edition NICEIC regulations. Regular portable appliance testing takes place. A member of the Facilities Team has been trained in this role. Records of all tests are kept in the Facilities office. The heads of Science and Design check that all Scientific and Design equipment is switched off at the end of the school day. All computers, projectors, printers and electronic whiteboards have been set to switch off automatically every evening. The Catering Manager checks that all kitchen equipment is switched off at the end of the day. Page 11 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

12 Lightning Protection All lightning protection and earthing conforms to BS It is tested annually by a specialist contractor. Records of all tests are kept in the Facilities Office. Gas Safety All gas appliances (boilers, kitchen equipment etc) are regularly maintained and serviced by Gas Safe Registered Engineers. Records of all tests are kept in the Facilities Office. Landlord s gas safety certificates are held for all school domestic accommodation. All kitchen equipment is switched off at the end of service. All laboratories are checked daily to ensure that the central gas supply is turned off. The cylinder gas for the DT workshop is switched off at the end of each day. Safe Storage We ensure that flammable materials used in teaching or maintenance are locked in purpose-made, flame-proof containers at the end of every day. Rubbish and Combustible Materials Flammable rubbish is stored away from buildings in the secured rubbish compound. Combustible materials used in teaching, catering, maintenance, grounds and caretaking are stored in flame proof cupboards. LETTING OR HIRING THE SCHOOL Our standard contractual terms, that we use for letting and hiring the school cover fire safety and specify that the hirer should certify that he/she has read and understood the school s fire safety policy and procedures. The Lettings Manager and a member of the Facilities department are always on duty when the school is let or hired for an outside function or event. Page 12 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

13 PART THREE FIRE RISK ASSESSMENT The School s Fire Risk Assessments meet the requirements of the Regulatory Reform (Fire Safety) Order 2005 (the FSO). Specifically they identify: The hazards The people at risk The measures to evaluate, remove, reduce and protect from the risk The measures needed to record, plan, inform, instruct and train people in risk reduction or removal The arrangements for reviewing the assessment All fire risk assessments follow a standard grid procedure for evaluating risk, and we are progressively updating them to follow the format of PAS 79: At Bedales Schools, we use simple line diagrams to supplement the grids. Bedales Schools have fire risk assessments which are updated every 3 years, or more frequently if significant changes are made to the interior of buildings, or new buildings are bought or added. Copies of Bedales Schools fire risk assessments are available for all staff to read, together with this document. Any comments or suggestions for improvement are always welcome. All Heads of Department should ensure that they and their staff read the sections applicable to them. Page 13 of 15 Last updated October 2011 Bursar\Policies\Fire Safety, Fire Procedures &

14 Bursar\Policies\Fire Safety, Fire Procedures & Page 14 of 15 Last updated October 2011

15 Fire Alarm: Whole School Evacuation Procedures If you hear the whole school fire alarm, proceed quietly and calmly to the Astroturf pitch. Assembly points are as follows: Basketball Court Steephurst Boys Flat Accounts Admin Bedales Services Catering Domestic Estates/Facilities HR IT Nurses House Staff, Tutors and Matrons House Staff, Tutors and Matrons Day Girls House Staff, Tutors and Matrons Day Boys Entrance to Astroturf Teaching Staff & Technicians Line up in silence and wait for the register to be called by House Staff. Teaching staff will be checked by HoDs reporting to Deputy Managing Head, or in his absence, the Chair of Common Room. Support staff to be checked by Facilities Admin after confirmation from each manager that staff are accounted for. Once all names are checked, and the Fire Officer gives the go-ahead, leave in an orderly way as follows: Support staff; teaching staff; day girls; day boys; Steephurst; 6.2; boys flat. Please note that these arrangements apply for whole school evacuation for fire or any other emergency. Local area evacuation procedures are posted in the buildings concerned. As a rule of thumb, exit the building and move to the nearest safe, open area. Bursar\Policies\Fire Safety, Fire Procedures & Page 15 of 15 Last updated October 2011

Fire Safety Procedures & Risk Assessment Policy

Fire Safety Procedures & Risk Assessment Policy Fire Safety Procedures & Risk Assessment Policy Part 1: Fire Safety INTRODUCTION Our priority is to minimise the risk to life and to reduce injury by maintaining the physical fire safety integrity of the

More information

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY Under the terms of the Box Hill School must ensure the safety from fire of all staff, pupils, contractors and visitors. In order to do this the school

More information

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY PART 1: FIRE SAFETY INTRODUCTION Our priority is to minimise the risk to life and to reduce injury by maintaining the physical fire safety of the

More information

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES Member of staff responsible : Headmaster Date of policy review : June 2018 Date of next review : June 2019 Approved by Governors : June 2018 KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

More information

FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY PART 1: FIRE SAFETY

FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY PART 1: FIRE SAFETY FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY PART 1: FIRE SAFETY INTRODUCTION Our priority is to minimise the risk to life and to reduce injury by maintaining the physical fire safety integrity of

More information

Fire Safety, Procedures and Risk Assessment Policy

Fire Safety, Procedures and Risk Assessment Policy Fire Safety, Procedures and Risk Assessment Policy Policy Type Regulatory Last Review Summer 2017 Next Review Summer 2018 Fire Safety, Procedures and Risk Assessment Policy 1. Fire Safety Introduction

More information

On no account should anyone return to a burning building.

On no account should anyone return to a burning building. H5. Fire Safety Procedures Policy Briefing New Staff and Pupils All our new staff (teaching and non-teaching alike) and all new pupils are given a briefing on the school s emergency evacuation procedures

More information

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

Fire. This policy applies to all members of our school community, including those within the EYFS setting. Fire Contents Pages Policy Statement 1 Policy 1-3 Fire Procedures 3-4 Out of Hours 4 Visitors 4 Fire Prevention Measures 5-6 Fire Safety Checks and Records 6-7 All Employees should 7 Risk Assessment on

More information

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School FIRE SAFETY POLICY This policy refers to both Wellington Senior School and Wellington Prep School Headmaster Henry Price Author Bursar Date Reviewed 27.06.2017 for implementation on 25.07.2017 Date of

More information

FIRE EMERGENCY PLAN AND FIRE RISK (PREVENTATION) POLICY

FIRE EMERGENCY PLAN AND FIRE RISK (PREVENTATION) POLICY This school is committed to safeguarding and promoting the welfare of children and young people and expects all staff and volunteers to share this commitment. Edition: 3 rd November 2016 FIRE EMERGENCY

More information

b. Fire Alarm System operating notes

b. Fire Alarm System operating notes St George s School, Windsor Castle Fire Policy & Procedures 1. Overview 2. Roles and responsibilities a. General b. Specific duties in the event of an emergency 3. Procedures a. In the event of an emergency

More information

THE HABERDASHERS ASKE S BOYS SCHOOL FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY

THE HABERDASHERS ASKE S BOYS SCHOOL FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY Introduction THE HABERDASHERS ASKE S BOYS SCHOOL FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY This policy has been reviewed in accordance with the statutory guidance set out in Part 3 Paragraph 12,

More information

Arbour House. Fire Policy and Procedures

Arbour House. Fire Policy and Procedures Arbour House Fire Policy and Procedures Policy Review Date: May 2017 Introduction Arbour House School endeavours to ensure that risks from fire are identified and that arrangements are in place to control

More information

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS The Joint Heads of Cundall Manor School have overall responsibility for ensuring that statutory fire precautions in relation to the Health & Safety at Work

More information

Fire Prevention and Procedures Policy

Fire Prevention and Procedures Policy Fire Prevention and Procedures Policy Last Reviewed: October 2017 Next review due: October 2018 Policy Owner: School Business Manager Policy Statement Lyndhurst School is committed to ensuring that, as

More information

RYDES HILL PREPARATORY SCHOOL & NURSERY P28 (ISI 12B) FIRE SAFETY POLICY (INCLUDES EYFS)

RYDES HILL PREPARATORY SCHOOL & NURSERY P28 (ISI 12B) FIRE SAFETY POLICY (INCLUDES EYFS) RYDES HILL PREPARATORY SCHOOL & NURSERY P28 (ISI 12B) FIRE SAFETY POLICY (INCLUDES EYFS) MISSION STATEMENT Rydes Hill Preparatory School and Nursery is a Catholic School where children learn how to live

More information

Whole School Fire Risk Prevention and Emergency Evacuation Procedures

Whole School Fire Risk Prevention and Emergency Evacuation Procedures Whole School Fire Risk Prevention and Emergency Evacuation Procedures (Also refer to Whole School Fire Risk Prevention Policy.) Policy Statement: All new staff (teaching and non-teaching) are given a briefing

More information

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY LEICESTER GRAMMAR SCHOOL TRUST LEICESTER GRAMMAR SCHOOL POLICY STATEMENT FIRE SAFETY POLICY It is Leicester Grammar School Trust s policy to protect all persons on the Leicester Grammar School premises

More information

Fire Evacuation Policy

Fire Evacuation Policy Fire Evacuation Procedures Policy Fire Evacuation Policy Contents Page Number Introduction 2 Staff Responsibilities and Training 2 Protective Equipment Fire Extinguishers 3 Inspection Procedures/Good Housekeeping

More information

GHS 8-4 Fire Policy and Procedures

GHS 8-4 Fire Policy and Procedures Contents Policy Statement... 1 Policy... 1 Fire Procedure... 2 Out of School Hours... 3 Senior School... 4 Junior School... 4 Visitors... 4 Fire Training... 5 Contractors... 6 Policy Statement Guildford

More information

Fire Safety Policy LENT 2018

Fire Safety Policy LENT 2018 Fire Safety Policy LENT 2018 Contents 1. Statement of Intent 2. Roles and Responsibilities 3. Emergency Evacuation Notice 4. Fire Safety Procedures 5. Fire Prevention Measures 6. Audit and Review 7. Fire

More information

FIRE SAFETY POLICY AND PROCEDURE. Date: November 2018

FIRE SAFETY POLICY AND PROCEDURE. Date: November 2018 FIRE SAFETY POLICY AND PROCEDURE Written by: Health & Safety Manager Date: November 2018 Review Date: November 2019 Person responsible for review: Health & Safety Manager AMDG Fire Safety Policy PART 1:

More information

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS Procedures Due concern is taken that the Regulatory Reform (Fire Safety) Order 2005 is complied with. The School

More information

Wincham Community Primary School

Wincham Community Primary School Wincham Community Primary School Fire Action Plan Policy Our School Mission Statement Learning together for the future in a safe, happy and supportive community. Approved and adopted by Governors Spring

More information

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017 GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017 OBJECTIVE This policy is designed to help our school comply with our duties under the Regulatory Reform (Fire Safety Order) 2005. Contents:

More information

Simon Woodfield Facilities Manager Governor Committee Policy Status Developed September 2009 Updated February 2017 Governor Approved June 2016

Simon Woodfield Facilities Manager Governor Committee Policy Status Developed September 2009 Updated February 2017 Governor Approved June 2016 Name of Policy Fire Evacuation Policy Lead Simon Woodfield Facilities Manager Governor Committee Policy Status Developed September 2009 Updated February 2017 Governor Approved June 2016 Review Frequency

More information

St Edward s Oxford FIRE SAFETY POLICY

St Edward s Oxford FIRE SAFETY POLICY FIRE SAFETY POLICY 1 CONTENTS Section Page No.(s) 1. Policy Statement 3-5 2. Organisation and Responsibilities 6 3. Responsibilities of Responsible Person 7-8 4. Responsibilities of Senior Management 9

More information

FIRE PROCEDURES 1. APPOINTMENTS

FIRE PROCEDURES 1. APPOINTMENTS 12b FIRE PROCEDURES 1. APPOINTMENTS Responsible Person In compliance with the Regulatory Reform (Fire Safety) Order 2005 (FSO), the School s Head, Mrs C Cameron is appointed as the Responsible Person for

More information

Fire Policy and Procedures St Helen s School

Fire Policy and Procedures St Helen s School St Helen s School September 2016 1. Introduction 1.1 St. Helen s School Northwood (the School) is required to have a fire policy under the Regulatory Reform (Fire Safety) Order 2005. 1.2 The School s priority

More information

WARWICK PREPARATORY SCHOOL

WARWICK PREPARATORY SCHOOL WARWICK PREPARATORY SCHOOL FIRE PROCEDURES Last Review: Autumn Term 2018 Next Review: Spring Term 2019 Responsible: Executive Assistant to the Head & Deputy Head CONTENTS 1. Introduction 2. Organisation

More information

EVACUATION PROCEDURES IN EDUCATION PREMISES

EVACUATION PROCEDURES IN EDUCATION PREMISES EVACUATION PROCEDURES IN EDUCATION PREMISES MARCH 2009 ISSUE 01 1.0 INTRODUCTION 1.1 Every establishment will have its own individual evacuation procedure which should cover the following basic facts:

More information

GENERAL - Regulatory. Fire Policy, Risk Assessment and Prevention (ISI 12a) Fire Procedures (ISI 12b)

GENERAL - Regulatory. Fire Policy, Risk Assessment and Prevention (ISI 12a) Fire Procedures (ISI 12b) GENERAL - Regulatory Fire Policy, Risk Assessment and Prevention (ISI 12a) Fire Procedures (ISI 12b) This Policy covers EYFS Contents: Page: Policy and Risk Assessment Fire Prevention Specific Responsibilities

More information

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures 161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means

More information

Evacuation Procedure and Fire Safety Policy

Evacuation Procedure and Fire Safety Policy Evacuation Procedure and Fire Safety Policy Reviewed by the Resources Committee: Review Date: January 2017 Nexus Education Schools Trust (NEST) group of schools Evacuation Policy The overall aim is to

More information

Millfield Schools Fire Risk Prevention Policy

Millfield Schools Fire Risk Prevention Policy Millfield Schools Fire Risk Prevention Policy This policy refers to the Senior School, Preparatory School, Pre-Preparatory School and EYFS 1. Introduction This policy sets out the approach that the school

More information

Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019

Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019 Fire Safety Policy (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January 2018 Next Review: January 2019 Person Responsible: School Business Manager 1 P age 1. INTRODUCTION a) King Fahad

More information

Wellsprings Primary School. Fire Emergency Evacuation Plan

Wellsprings Primary School. Fire Emergency Evacuation Plan Wellsprings Primary School Fire Emergency Evacuation Plan This Emergency Plan has been developed following fire risk assessments of the relevant building. The purpose of the plan is: To ensure the safety

More information

KELSO HIGH SCHOOL EMERGENCY EVACUATION PROCEDURE

KELSO HIGH SCHOOL EMERGENCY EVACUATION PROCEDURE KELSO HIGH SCHOOL EMERGENCY EVACUATION PROCEDURE AIM The aim of the Emergency Evacuation procedure is to ensure the safe and speedy evacuation of the school buildings and to provide an accurate method

More information

FIRE SAFETY POLICY. Reviewed Autumn Next Review Autumn 2019 by Bursar/Dep Hd Pastoral/ Governors

FIRE SAFETY POLICY. Reviewed Autumn Next Review Autumn 2019 by Bursar/Dep Hd Pastoral/ Governors FIRE SAFETY POLICY Reviewed Autumn 2018 Next Review Autumn 2019 by Bursar/Dep Hd Pastoral/ Governors 1 1.1 INTRODUCTION The priority in fire safety is to minimise the risk to life and to reduce injury

More information

FIRE SAFETY POLICY. This policy document replaces any previously published documents and comes into effect September 2018.

FIRE SAFETY POLICY. This policy document replaces any previously published documents and comes into effect September 2018. FIRE SAFETY POLICY This policy document replaces any previously published documents and comes into effect September 2018. 1.0 Fire Safety: The priority of Shrewsbury School is to minimise the risk to life

More information

Evacuation Procedure and Fire Safety Policy

Evacuation Procedure and Fire Safety Policy Evacuation Procedure and Fire Safety Policy Contents 1. Evacuation Policy 2. Fire Safety Policy Appendix 1 Roles and Responsibilities Appendix 2 Checklist for First Day Fire Safety Instruction Appendix

More information

Charlotte Building, 17 Gresse Street, London W1T 1QL

Charlotte Building, 17 Gresse Street, London W1T 1QL Charlotte Building, 17 Gresse Street, London W1T 1QL Fire Safety Management & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of

More information

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY Last Review Date 30 June 2015 Policy endorsed by Policy is maintained by ISI reference Trustees Co-Principals/Directors A9, B6, B9 Next review date 30 August

More information

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy Peponi House Preparatory School Nairobi, Kenya Peponi House Fire Risk Prevention Policy 1. Introduction This policy outlines the school s approach to securing fire safety. It is based on; HM Government,

More information

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours Grand Avenue Primary and Nursery School Policy for Fire Safety Contents 1. Aims/Objectives 2. Prevention of fire Maintenance 3. Prevention of fire - Responsibilities 4. Prevention of fire Fire Safety Training

More information

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY Under the terms of the Regulatory Reform (Fire Safety) Order 2005, and subsequent regulations, Seaford College must ensure the safety from fire of all staff,

More information

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY   1. Policy Fire Safety Policy 1. Policy It is the policy of Malden Oaks to minimise the risks to students, staff and others which may arise from fire. This is achieved by ensuring precautions are taken to avoid fires

More information

Fire Safety Policy. Signed Date September on behalf of the Management Committee. on behalf of The Woodlands

Fire Safety Policy. Signed Date September on behalf of the Management Committee. on behalf of The Woodlands Fire Safety Policy Signed Date September 2018 on behalf of the Management Committee Signed Date September 2018 on behalf of The Woodlands To be reviewed: September 2019 All staff need to ensure that they

More information

Fire Policy and Procedures. Cañada Blanch Spanish School

Fire Policy and Procedures. Cañada Blanch Spanish School Fire Policy and Procedures Cañada Blanch Spanish School SUMMARY 1. Introduction (p. 3) 2. Roles and responsibilities (p. 3) -- Headteacher -- Fire Team -- All staff -- Contractors 3. Fire procedures (p.

More information

Glenmere Primary School Fire Safety Policy FIRE SAFETY POLICY. Revised on April Sam Conlon. Created by S.Conlon 1

Glenmere Primary School Fire Safety Policy FIRE SAFETY POLICY. Revised on April Sam Conlon. Created by S.Conlon 1 FIRE SAFETY POLICY Revised on April 2018 By Sam Conlon Created by S.Conlon 1 Legal framework Contents Responsibilities of local governing body Responsibilities of Headteacher Responsibilities of premises

More information

EMERGENCY EVACUATION PLAN for FIRE

EMERGENCY EVACUATION PLAN for FIRE St.Thomas More s Catholic Primary School EMERGENCY EVACUATION PLAN for FIRE This plan provides guidance and information for the occupants of St Thomas More's Catholic School and the Emergency Control Organisation

More information

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School OBJECTIVE This Fire Safety Policy is designed to help Putnoe Primary School comply with their duties under the Regulatory Reform (Fire Safety

More information

Fire Evacuation Procedure

Fire Evacuation Procedure Fire Evacuation Procedure 1. ON HEARING THE FIRE ALARM or DISCOVERING FIRE during normal operating hours: With immediate effect the school staff listed below has the following responsibilities: Estates

More information

Fire Evacuation Procedure St James Junior School and St James Senior Girls School

Fire Evacuation Procedure St James Junior School and St James Senior Girls School Fire Evacuation Procedure St James Junior School and St James Senior Girls School 1 Staff Responsibilities 1.1 With immediate effect the staff listed below have the following responsibilities: Estates

More information

Fire Safety Protocol

Fire Safety Protocol CORPORATE HEALTH AND SAFETY POLICY: Part 3 Arrangements Fire Safety Protocol Document Status: [ ] Guidance for Managers [] Protocol [ ] Procedures Version 0.1/ August 2013 DRAFT EALING NCIL Table of Contents

More information

OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016

OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016 OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016 1 CONTENTS 1. School arrangements and organisation 2. Hazardous materials identification 2.1 Electrical 2.2 Chemical 2.3 Gas 2.4 Furniture

More information

Asmall Primary School

Asmall Primary School Asmall Primary School FIRE PROCEDURES June 2013 s ANYONE (CHILD OR STAFF) discovering an outbreak of fire should, without hesitation, sound the nearest fire alarm. The function of the alarm signal is to

More information

Fire safety policy (Including Fire Emergency Plan)

Fire safety policy (Including Fire Emergency Plan) Fire safety policy (Including Fire Emergency Plan) Action Policy to be reviewed as required and at least annually Committee Date Completed Review Health & Safety Committee 21 February 2018 Reported Finance

More information

Fire Safety and Emergency Evacuation. Herne Bay Junior School. Compassion Courage Hope Integrity Justice Respect Responsibility - Wisdom

Fire Safety and Emergency Evacuation. Herne Bay Junior School. Compassion Courage Hope Integrity Justice Respect Responsibility - Wisdom Compassion Courage Hope Integrity Justice Respect Responsibility - Wisdom Fire Safety and Emergency Evacuation Policy Agreed: Sept 2016 Review Date: Sept 2017 Page 1 INTRODUCTION The main aim in any emergency

More information

Kings Fire Safety Policy

Kings Fire Safety Policy Kings Fire Safety Policy All Kings policies will be ratified by the Board of Directors and signed by the Chairperson. Each policy will be co-signed by the principal of each school. Review dates will be

More information

NEWBATTLE ABBEY COLLEGE. Fire Safety and Emergency Evacuation Policy and Procedure

NEWBATTLE ABBEY COLLEGE. Fire Safety and Emergency Evacuation Policy and Procedure NEWBATTLE ABBEY COLLEGE Fire Safety and Emergency Evacuation Policy and Procedure 1. Scope of Policy The College acknowledges that emergency situations may arise and that it has a responsibility to ensure

More information

ASHGATE CROFT SCHOOL FIRE PREVENTION AND EVACUATION PROCEDURES

ASHGATE CROFT SCHOOL FIRE PREVENTION AND EVACUATION PROCEDURES ASHGATE CROFT SCHOOL FIRE PREVENTION AND EVACUATION PROCEDURES Introduction Establishments need to carry out a risk assessment to specifically assess the potential fire risks within the workplace. All

More information

Fire Procedures. April 2016

Fire Procedures. April 2016 Estates Department Fire Procedures April 2016 Author Robert Hardman Estates Manager Last Policy Review Date 1/04/16 Next policy Review Date 1/04/17 Reviewed by The Laurus Trust School Fire Procedures Contents

More information

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy.

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy. Fire Safety Management Policy Aim of the academy To provide a unique and enriching opportunity for all. Principles This plan should be read in conjunction with the Health and Safety Policy. We are committed

More information

Elutec Fire and Evacuation Procedure

Elutec Fire and Evacuation Procedure Elutec Fire and Evacuation Procedure Policy This policy is in place for the following reasons: to ensure the safety and welfare of staff and students of Elutec; to have in place adequate, reasonable and

More information

Fire safety procedure

Fire safety procedure Fire safety procedure Review date: October 2020 Responsible (s): Health and Safety Applicable to Staff: Accessible to Students: Accessible to general public: (including clients) Yes Yes Yes 1 Contents

More information

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1 Billy Hanafin H & S and Operations Officer Version 1.0 October 2013 Page 1 1. General The Trust is a responsible employer that takes its Fire Safety duties seriously. For that reason, this policy has been

More information

Fire Emergency Procedure

Fire Emergency Procedure Fire Emergency Procedure This policy applies to all staff and children from EYFS to Year 6 (including the Nurture Provision) Chair of Governors:- Mrs Christine Bartley Headteacher:- Mrs Elaine Preston

More information

2. Aim. The aim of the fire and fire prevention policies are to ensure the safety of pupils, staff and all visitors to the School.

2. Aim. The aim of the fire and fire prevention policies are to ensure the safety of pupils, staff and all visitors to the School. Policy Fire and fire prevention policy Written by Bursar Date for Review Sep 19 FIRE AND FIRE PREVENTION POLICY 1. Introduction. This policy is applicable to all pupils including those in the EYFS. The

More information

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means for Fighting Fire 5. 0 Discovering

More information

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY University of Maryland FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your

More information

Fire Safety Policy (A11)

Fire Safety Policy (A11) Fire Safety Policy (A11) Scope: Whole School Release date: September 18 Review date: September 19 Author: Deputy Head Academic Reviewer: Health and Safety Advisor Approval body: Risk and Governance Committee

More information

Whitley Abbey Primary School

Whitley Abbey Primary School Resources Directorate Health & Safety Services Fire and Emergency Plan February 2015 AMENDED FEB 2O15 FOR NEW BUILD Whitley Abbey Primary School General Procedures The school's fire risk assessment and

More information

ST BEDE S CATHOLIC PRIMARY SCHOOL & NURSERY MANAGED FIRE PLAN

ST BEDE S CATHOLIC PRIMARY SCHOOL & NURSERY MANAGED FIRE PLAN ST BEDE S CATHOLIC PRIMARY SCHOOL & NURSERY MANAGED FIRE PLAN Together in the Lord we will love, listen and learn February 2012 Review date: February 2015 CONTENTS RESPONSIBILITIES... 3 STAFF TRAINING...

More information

Ruishton C of E Primary School

Ruishton C of E Primary School Ruishton C of E Primary School Fire Safety Policy (inc Induction Training) & Emergency Plan Date: April 2018 To be Reviewed: April 2020 Fire Safety Duties The following persons have fire safety responsibility

More information

Ealing Independent College. Fire Policy. This Policy Applies to all students and staff of Ealing Independent College

Ealing Independent College. Fire Policy. This Policy Applies to all students and staff of Ealing Independent College Ealing Independent College Fire Policy This Policy Applies to all students and staff of Ealing Independent College Addresses of College Buildings: Main Building: Boarding House: Ealing Independent College,

More information

FIRE & FIRE PREVENTION POLICY AND PROCEDURE

FIRE & FIRE PREVENTION POLICY AND PROCEDURE FIRE & FIRE PREVENTION POLICY AND PROCEDURE Policy Statement Milton Abbey School recognises the dangers associated with fire and will take all reasonable steps to ensure that its premises have appropriate

More information

Fire Safety Policy 2018/19

Fire Safety Policy 2018/19 Fire Safety Policy 2018/19 Reviewed: March 2016 Next Review: March 2019 1. Policy Statement The School is committed to ensuring, so far as is reasonably practicable, the health, safety and welfare of all

More information

EMERGENCY EVACUATION PLAN

EMERGENCY EVACUATION PLAN UCL ESTATES & FACILITIES DIVISION Construction Maintenance & Fire Safety UNIVERSITY COLLEGE LONDON EMERGENCY EVACUATION PLAN Regulatory Reform (Fire Safety) Order 2005 Name & Address of Building: Occupying

More information

FIRE POLICY This Policy includes the Nursery and Early Years Foundation Stage

FIRE POLICY This Policy includes the Nursery and Early Years Foundation Stage REVIEWED: SEPTEMBER 2015 NEXT REVIEW DATE: AUTUMN 2016 REVIEWED BY: BURSAR SIGNED BY: HEAD FIRE POLICY This Policy includes the Nursery and Early Years Foundation Stage Procedures are in place to ensure

More information

FIRE SAFETY POLICY. A. Policy Statement

FIRE SAFETY POLICY. A. Policy Statement Overall responsibility for Fire Safety: Delegated responsibility for Fire Safety: Mr J Crocker (Principal) Ms C Lepeck (Student Services Manager) A. Policy Statement This policy has been prepared to help

More information

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES MANOR INFANT SCHOOL & NURSERY Approval By: School Review Frequency: 2 years Next Review Due: February 2020 Last Reviewed: February 2018 CHAIR OF GOVERNORS & HEADTEACHER TO COMPLETE Review Approved (signature):

More information

DEF Fire Evacuation and Emergency Planning Criteria

DEF Fire Evacuation and Emergency Planning Criteria DEF Fire Evacuation and Emergency Planning Criteria This criteria should be used to devise individual DEF specific fire evacuation and emergency plans. It is the responsibility of the Clinic Team Leader

More information

EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018

EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018 EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018 INTRODUCTION This document outlines the main procedures to be followed in the event of a fire incident at Sir Christopher

More information

Sir Christopher Hatton Academy A Member of Hatton Academies Trust

Sir Christopher Hatton Academy A Member of Hatton Academies Trust EMERGENCY EVACUATION PROCEDURE June 2015 INTRODUCTION This document outlines the main procedures to be followed in the event of a fire incident at Sir Christopher Hatton Academy ( the Academy ). Whilst

More information

Fire Safety Policy. Reviewer: Senior Deputy Headmaster Last Reviewed: September Version 1

Fire Safety Policy. Reviewer: Senior Deputy Headmaster Last Reviewed: September Version 1 Fire Safety Policy Owner: Bursar Reviewer: Senior Deputy Headmaster Last Reviewed: September 2016 Version 1 STATEMENT OF INTENT Solihull School is committed to providing a safe environment for its staff,

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT FIRE RISK ASSESSMENT ESTABLISHMENT: Address: WAVERLEY SCHOOL 105 The Ride Enfield EN37DL Assessor: (print) Responsible Person: G WILLIAMS Signature G Williams GAIL WEIR (Head Teacher) Date: Review date

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE FIRE RISK ASSESSMENT SPORTS CENTRE BUILDING SUMMARY The building is used as a Sports Centre and contains a large sports hall with changing rooms, an office for staff and a fitness area. 1. Identification

More information

NEWTOWN LINFORD PRIMARY SCHOOL. Emergency Procedures Policy

NEWTOWN LINFORD PRIMARY SCHOOL. Emergency Procedures Policy NEWTOWN LINFORD PRIMARY SCHOOL Emergency Procedures Policy Aim The aim of this policy is to outline emergency procedures resulting from incidents and situations which could have a possible effect on the

More information

Fire Safety Policy. General Policy Statement 1. Responsibilities 2. Fire Safety Procedures 5. Fire Precaution and Prevention 6. Fire Risk Assessment 7

Fire Safety Policy. General Policy Statement 1. Responsibilities 2. Fire Safety Procedures 5. Fire Precaution and Prevention 6. Fire Risk Assessment 7 Fire Safety Policy Page General Policy Statement 1 Responsibilities 2 Fire Safety Procedures 5 Fire Precaution and Prevention 6 Fire Risk Assessment 7 Records & Other Information 8 Fire, Evacuation and

More information

Fire Evacuation Procedure

Fire Evacuation Procedure Fire Evacuation Procedure If you hear the fire alarm sound, evacuate the building immediately. The nearest fire exit is clearly signed wherever you are within the school building, and the priority is to

More information

Fire and Bomb. Evacuation Policy

Fire and Bomb. Evacuation Policy Fire and Bomb Evacuation Policy January 2017 1 FIRE SAFETY 1. PROCEDURE Manford Primary School follows procedures on the Blue Dot RIDDER poster. Any person discovering a fire must sound the alarm immediately

More information

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between FIRE SAFETY PROCEDURES, ST MARY S CAMPUS MEDICAL SCHOOL BUILDING These notes supplement the Imperial College London Fire Safety Policy and Code of Practice and give details of local fire safety management

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS FIRE RISK ASSESSMENT NEW BUILDINGS BUILDING SUMMARY The building is utilised for classroom teaching for Modern Languages. 1. Identification of the hazards 1.1 Identification of sources of fuel. Timber

More information

Fire Drill Policy. Facilities Manager DCD. Statutory. Principal. Staff. REVIEW DATE 20 th August Owner. Version Number: 8 Legal Sign:

Fire Drill Policy. Facilities Manager DCD. Statutory. Principal. Staff. REVIEW DATE 20 th August Owner. Version Number: 8 Legal Sign: Fire Drill Policy REVIEW DATE 20 th August 2018 Owner Facilities Manager Version Number: 8 Legal Sign: DCD Type of Policy: Statutory Authorized by: Principal Authorized by Board: 14 th September 2017 Effective

More information

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES MANOR INFANT SCHOOL Approval By: School Review Frequency: 3 years Next Review Due: March 2018 Last Reviewed: March 2015 CHAIR OF GOVERNORS & HEADTEACHER TO COMPLETE Review Approved (signature): Date Approved:

More information

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be EMLC Academy Trust Fire Safety Policy 2017/19 Every child deserves to be the best they can be 1 Scope: EMLC Academy Trust & Academies within the Trust Version: 2 Filename: EMLC Academy Trust Fire Safety

More information

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL Health & Safety Contents Health & Safety... 1 Contents... 2 HEALTH AND SAFETY STRATEGY... 3 GOVERNORS STATEMENT... 3 STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL... 3 HEALTH

More information

HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY

HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY INTRODUCTION Cwmni CYNNAL recognises its duty of care to employees and all reasonable steps will be taken to secure the health and safety of employees.

More information

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL This document details the fire and emergency evacuation procedures for the premises. Staff should ensure that they are familiar with these

More information