ZITON. the. big picture. ZP3 Fire Detection Systems for large networks. imagination at work

Size: px
Start display at page:

Download "ZITON. the. big picture. ZP3 Fire Detection Systems for large networks. imagination at work"

Transcription

1 ZITON the big picture ZP3 Fire Detection Systems for large networks imagination at work

2 Ziton Fire Detection Networks Royal Farms Saudi Arabia 8 control panels, operating 22,00 sensing devices. DETECTING FIRES IS EASY ENOUGH; DECIDING WHAT TO DO AFTER A FIRE HAS BEEN DISCOVERED TO PROTECT PEOPLE AND BUILDINGS, WITHOUT CAUSING ADDITIONAL DAMAGE OR UNNECESSARY DISRUPTION, IS MUCH HARDER. THAT S WHERE WE CAN HELP. St.Regis Hotel and Residence Singapore 29 control panels, operating 1,600 sensing devices. All Ziton fire detection systems are designed to detect and locate fires and provide a controlled response. Whether you have one building or multiple sites spread throughout the country, we have the technology to put you in control. Our ZP3 system is our flagship product designed for installations from a single panel system up to networks of 100 panels, monitoring up to 50,000 sensors at multiple locations. It is packed with innovative features and practical benefits to make it reliable, effective and easy to use; while our Maestro system management programme puts total fire detection capability at your fingertips. Features include: Single- panel and Multi-panel systems For easy monitoring and simple installation. Peer-to-peer networking Providing a display of the system from all panels. Local Area Networks (LAN) For single-site installations. Wide Area Networks (WAN) For multi-site installations. Secure Network Loop Technology So that the system still performs perfectly even if a single fault develops. Flexible topology So you can scale up the system as your site grows. Queens Medical Centre England 84 control panels, operating 35,000 sensing devices. The ZP3 analogue addressable control panel range, in one, two and four loop versions, with peer-to-peer networking, allows for systems of up to 100 panels with over 50,000 sensors.

3 Ziton Fire Detection Networks Royal Farms Saudi Arabia 8 control panels, operating 22,00 sensing devices. DETECTING FIRES IS EASY ENOUGH; DECIDING WHAT TO DO AFTER A FIRE HAS BEEN DISCOVERED TO PROTECT PEOPLE AND BUILDINGS, WITHOUT CAUSING ADDITIONAL DAMAGE OR UNNECESSARY DISRUPTION, IS MUCH HARDER. THAT S WHERE WE CAN HELP. St.Regis Hotel and Residence Singapore 29 control panels, operating 1,600 sensing devices. All Ziton fire detection systems are designed to detect and locate fires and provide a controlled response. Whether you have one building or multiple sites spread throughout the country, we have the technology to put you in control. Our ZP3 system is our flagship product designed for installations from a single panel system up to networks of 100 panels, monitoring up to 50,000 sensors at multiple locations. It is packed with innovative features and practical benefits to make it reliable, effective and easy to use; while our Maestro system management programme puts total fire detection capability at your fingertips. Features include: Single- panel and Multi-panel systems For easy monitoring and simple installation. Peer-to-peer networking Providing a display of the system from all panels. Local Area Networks (LAN) For single-site installations. Wide Area Networks (WAN) For multi-site installations. Secure Network Loop Technology So that the system still performs perfectly even if a single fault develops. Flexible topology So you can scale up the system as your site grows. Queens Medical Centre England 84 control panels, operating 35,000 sensing devices. The ZP3 analogue addressable control panel range, in one, two and four loop versions, with peer-to-peer networking, allows for systems of up to 100 panels with over 50,000 sensors.

4 ZP3 Control Panel Building the system you need THE ZP3 CONTROL PANEL IS THE BUILDING BLOCK THAT ENABLES US TO BUILD A FIRE DETECTION AND RESPONSE SYSTEM THAT MEETS YOUR NEEDS. Each panel can control up to 508 devices such as smoke detectors, heat sensors, manual call points or sounders. Each device has a known location within the system for a fast, accurate response to any fire condition. Up to 100 panels can be linked together as a peer-to-peer network to create a unique system designed specifically for the location. The system can be controlled directly from the panel or from a remote PC. Multiple panels can be linked to single or multiple PCs to provide central control and monitoring either locally or remotely. The system can be configured, to interact with a Building System, to react automatically in a fire condition for example, to control air conditioning or ventilation equipment.

5 Local Area Networks (LAN) A Local Area Network operates within one building or a number of buildings on a single site such as: factories, shopping centres, hospitals, airports and university campuses. The site may include multistorey buildings or a number of smaller buildings spread over a large area. Each building or floor of a high-rise block can be controlled by its own ZP3 panel to meet the needs of that environment. Up to 100 panels can be linked over the whole site to create an integrated fire detection system. The panels operate on a peer-to-peer network. This allows all panels to display the status of the whole system and to be used for programming. Each panel can also be programmed to receive, display and action all or selected events. Network reliability is maintained by using a secure loop system to connect the panels together. This ensures that the system continues to operate normally even if a fault develops such as a wire being disconnected or a connection broken. Communication between the panels can be through hard wiring, fibre optics or, for larger sites, by radio signalling or modem. The whole network can be operated via a PC using our Ziton Maestro control system and graphic display. Features include: Up to 100 panels each separately programmable and operating up to 508 devices. Operates on sites with multiple buildings or on floors of high rise buildings. Peer-to-peer configuration for easy programming. Secure connections for total reliability in the event of a break in the network, sub networks are formed automatically. Choice of connection system (hard wire, fibre optic, R/F or modem). Maestro PC control. Wide Area Network (WAN) A Wide Area Network is a number of LANs linked together to provide much wider coverage for large industrial or commercial sites, railway or underground transport systems, or any large national or international organisation that needs a central fire detection and control system. Each LAN can be configured and operated independently but be linked to form a single multi-site system. Numerous local networks can be combined to form a WAN covering extensive geographical areas. Each local section can be given the ability to control both its own location and the entire WAN. Alternatively the WAN can be controlled separately from a remote location with the LANs retaining local control only. A WAN provides all the features and benefits of a LAN plus: The system can cover a number of locations. provided that a communication infrastructure is available. It can be controlled locally or centrally. PEER TO PEER

6 Fire Detection Systems Large and Small ZITON MULTI PANEL NETWORKS OPERATE WORLDWIDE, SUPPLIED AND ENGINEERED THROUGH 100 EXPERT PARTNER COMPANIES, SAVING LIVES AND PROTECTING PROPERTY TO THE SAME HIGH LEVEL REGARDLESS OF SYSTEM SIZE. No matter what the size of the installation, this completely scaleable system ensures the same protection levels and facilities whether it s a single high rise office block, a local network across a single site or widespread locations connected to form a complex net of fire detection control. Ziton multi panel systems work continuously on hundreds of sites in dozens of countries. Commercial, industrial, institutional, educational or residential establishments all use the same reliable building blocks connected to provide total reassurance against fire risks.

7 Fire Detection Systems Large and Small ZITON MULTI PANEL NETWORKS OPERATE WORLDWIDE, SUPPLIED AND ENGINEERED THROUGH 100 EXPERT PARTNER COMPANIES, SAVING LIVES AND PROTECTING PROPERTY TO THE SAME HIGH LEVEL REGARDLESS OF SYSTEM SIZE. No matter what the size of the installation, this completely scaleable system ensures the same protection levels and facilities whether it s a single high rise office block, a local network across a single site or widespread locations connected to form a complex net of fire detection control. Ziton multi panel systems work continuously on hundreds of sites in dozens of countries. Commercial, industrial, institutional, educational or residential establishments all use the same reliable building blocks connected to provide total reassurance against fire risks.

8 Planning Flexible Installation Comprehensive tools to help you create the fire detection system you need. OUR SYSTEMS ARE SIMPLE TO INSTALL AND HAVE BEEN DESIGNED WITH BUILT-IN SAFETY TO ENSURE TOTAL CAPABILITY EXACTLY WHEN YOU NEED IT MOST. Networks Radio Frequency Connection Networks of any size can be built in phases to provide protection during construction and as a site develops. Hardwiring large sites can be expensive and impractical. For these installations we recommend networking via Radio (RF) link. RF technology offers the opportunity to connect multi-location sites quickly and inexpensively without hardwiring and to upgrade installations as necessary. System Integration Installation Maintenance Easy-to-use diagnostic software for simple analysis of network status. Fast, cost-effective installation of the most appropriate system for your site. While local panels, LANs and WANs can provide extensive input and output (I/O) controls, all our systems can be integrated with building management, security and access control systems to provide the appropriate response to any alarm. This might include closing down air conditioning plant, grounding lifts, pressurising stairwells, or triggering appropriate extinguishers, especially in vital areas such as computer control rooms, vaults, libraries, museums or galleries. A variety of communication equipment can be used to ensure system integrity: modem connection for transmission and receipt of system data over long distances, repeater units to boost signals where appropriate, and isolators to provide protection for less robust parts of the network. Secure Network Loop Technology Safety Standards Secure Loop Technology gives the maximum system security even if the wiring becomes damaged. If there is a fault on the network, Network Loop Module cards within the system immediately identify where the fault lies and isolate it to keep as much of the network as possible intact and functioning properly. This means that even if the wiring is disconnected between two panels the network still operates at 100%. All our systems are designed and installed to meet international fire safety standards for example the European Standard EN54 for equipment manufacture and most local system design codes such as BS5839 Part 1 in the UK. Multi-medium communications Hardwiring Many customers prefer the security and confidence that hard wiring can offer. We use soft-skin fire retardant cables when appropriate and MICC (Mineral Insulated) where virtually indestructible, fire-survival cables are needed for critical installations. Fibre Optics All our systems can be installed using fibre optic connections rather than standard copper cables. They reduce the effects of electrical noise, perform well over distance and can provide total isolation between system media in industrial environments. SECURE LOOP TECHNOLOGY

9 Planning Flexible Installation Comprehensive tools to help you create the fire detection system you need. OUR SYSTEMS ARE SIMPLE TO INSTALL AND HAVE BEEN DESIGNED WITH BUILT-IN SAFETY TO ENSURE TOTAL CAPABILITY EXACTLY WHEN YOU NEED IT MOST. Networks Radio Frequency Connection Networks of any size can be built in phases to provide protection during construction and as a site develops. Hardwiring large sites can be expensive and impractical. For these installations we recommend networking via Radio (RF) link. RF technology offers the opportunity to connect multi-location sites quickly and inexpensively without hardwiring and to upgrade installations as necessary. System Integration Installation Maintenance Easy-to-use diagnostic software for simple analysis of network status. Fast, cost-effective installation of the most appropriate system for your site. While local panels, LANs and WANs can provide extensive input and output (I/O) controls, all our systems can be integrated with building management, security and access control systems to provide the appropriate response to any alarm. This might include closing down air conditioning plant, grounding lifts, pressurising stairwells, or triggering appropriate extinguishers, especially in vital areas such as computer control rooms, vaults, libraries, museums or galleries. A variety of communication equipment can be used to ensure system integrity: modem connection for transmission and receipt of system data over long distances, repeater units to boost signals where appropriate, and isolators to provide protection for less robust parts of the network. Secure Network Loop Technology Safety Standards Secure Loop Technology gives the maximum system security even if the wiring becomes damaged. If there is a fault on the network, Network Loop Module cards within the system immediately identify where the fault lies and isolate it to keep as much of the network as possible intact and functioning properly. This means that even if the wiring is disconnected between two panels the network still operates at 100%. All our systems are designed and installed to meet international fire safety standards for example the European Standard EN54 for equipment manufacture and most local system design codes such as BS5839 Part 1 in the UK. Multi-medium communications Hardwiring Many customers prefer the security and confidence that hard wiring can offer. We use soft-skin fire retardant cables when appropriate and MICC (Mineral Insulated) where virtually indestructible, fire-survival cables are needed for critical installations. Fibre Optics All our systems can be installed using fibre optic connections rather than standard copper cables. They reduce the effects of electrical noise, perform well over distance and can provide total isolation between system media in industrial environments. SECURE LOOP TECHNOLOGY

10 Operation and Configuration Maestro Central control of your entire alarm system. TO BE EFFECTIVE, SYSTEMS NEED TO BE SIMPLE TO SET UP AND TO OPERATE. OUR SYSTEMS ARE DESIGNED TO DO ALL THE HARD WORK SO THAT YOU DON T HAVE TO. Planner Remote Diagnosis Planner for Windows is a sophisticated software package specifically designed to provide a comprehensive, simple-to-use, off-line configuration of even the largest ZP3 systems. The programme allows you to develop systems taking into account complex cause and effect scenarios to ensure an appropriate response to any alarm. The remote diagnosis programme allows information from ZP3 control panels to be assessed from a remote PC location. This allows the system to be reconfigured off site including the downloading of software. An ongoing events schedule can be viewed allowing pre site visit maintenance planning to be developed. Maestro Maestro is an alarm management programme operated from a PC on site or located remotely. It allows you to view alarm conditions throughout the system shown graphically on the computer screen and respond appropriately. Remote Diagnostic Off-site monitoring for efficient maintenance programmes. Planner The ability to configure a system precisely to meet your needs.

11 Operation and Configuration Maestro Central control of your entire alarm system. TO BE EFFECTIVE, SYSTEMS NEED TO BE SIMPLE TO SET UP AND TO OPERATE. OUR SYSTEMS ARE DESIGNED TO DO ALL THE HARD WORK SO THAT YOU DON T HAVE TO. Planner Remote Diagnosis Planner for Windows is a sophisticated software package specifically designed to provide a comprehensive, simple-to-use, off-line configuration of even the largest ZP3 systems. The programme allows you to develop systems taking into account complex cause and effect scenarios to ensure an appropriate response to any alarm. The remote diagnosis programme allows information from ZP3 control panels to be assessed from a remote PC location. This allows the system to be reconfigured off site including the downloading of software. An ongoing events schedule can be viewed allowing pre site visit maintenance planning to be developed. Maestro Maestro is an alarm management programme operated from a PC on site or located remotely. It allows you to view alarm conditions throughout the system shown graphically on the computer screen and respond appropriately. Remote Diagnostic Off-site monitoring for efficient maintenance programmes. Planner The ability to configure a system precisely to meet your needs.

12 GE Security UK Ltd 8 Newmarket Court Chippenham Drive Kingston Milton Keynes MK10 OAQ England Tel: +44(0) Fax: +44(0) GE Security (Africa) 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax: +27 (0) GE Security

13 Ziton ZP3 Fire Detection Systems imagination at work

14 Building the system you need ZP3 TAKES ANALOGUE ADDRESSABLE FIRE DETECTION INTO NEW DIMENSIONS. BASED ON ADVANCED TECHNOLOGY, STATE OF THE ART SENSING TECHNIQUES AND SPECIALLY DESIGNED SOFTWARE THAT FEATURES BUILT IN RELIABILITY AND COMPLETE PEACE OF MIND. Advanced panel design, combined with high sensitivity smoke and fire sensing, enables ZP3 not only to identify and disregard conditions, which would result in false or unwanted alarms - but to recognise real fires sooner limiting inconvenience and reducing downtime to a minimum. Scaleable in every aspect, the ZP3 system offers tailor made engineered solutions for all applications, from single panel systems to large multi panel networks. Modular design backed by powerful software enables ZP3 systems to be configured exactly to the needs of any commercial or industrial site. Control panels are available in 1, 2, and 4 loop sizes, accommodating up to 508 sensing addresses. For larger systems, panels can be networked together to form installations capable of controlling over 50,000 devices from 100 control panels. Up to 127 line devices (sensors, callpoints, sounders or interface units) can be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address, the location of which is pinpointed and polled by the panel every two seconds. Variations in the sensors environment caused by increases of temperature or products of combustion, are reported to the panel, where they are processed and compared to known fire data, prior to any alarm output being activated. Constant communication between control panel and sensor, enables ZP3 to provide a wide range of user facilities including pre alarm, constant sensitivity adjustment and service and near service listings for all sensor types. Software flexibility enables facilities such as alarm organisation, evacuation procedures and complex cause and effect requirements to be easily programmed into any system. All customer and site data is held in non volatile flash memory, ensuring both ease of initial system data input and subsequent on site amendments and modifications should they occur. The ZP3 panel can control fire and non fire functions, loop powered sounders, remote control and remote display panels, with up to 128 zones with 768 programmable inputs and outputs per panel, all covered by comprehensive programming facilities. Ideal for systems of all sizes the ZP3 is designed with true scalability it s operation, facilities and levels of protection are the same from single panel, to large multi site network meaning that you can start small and add phases as the system and site develop, saving large initial capital outlays for hardware not required until later stages of development.

15 Active protocol means complete reliability at all times. Systems feature continuous monitoring of wiring and sensors, corrupt data detection and disconnection of faulty or impaired loop sections. Sensors, sounders and interface equipment can be installed on a single pair of wires, greatly reducing installation costs. All system components meet full the stringent requirements of European Standards and are continually tested by international testing laboratories (for example the Loss Prevention Certification Board LPCB). ZP3 also meets the recommendations of most local design and installation codes. Remote Display Unit Other features include Ease of operation - large 160 character LCD display and traditional LED indicators providing clear, easy to understand information. Automatic contamination adjustment maintains constant, individual sensor sensitivity by compensating for sensitivity drifting over time period. Service and near service lists sensors that are due for cleaning and others that may be approaching the service condition. Sophisticated alarm verification offers two time integration levels for each separate address. Advanced loop isolation maintains system integrity against partial or full short circuit faults. Automatic Self Test all sensors are functionally tested every 24 hours. Day/night control different system operation, automatically switched at any time during a 24 hour period. Sounder Self Test loop wired sounder range features built in microphone circuit to automatically test sounder output. Radio loop interface full analogue system facilities via wireless interface enables equipment to be sited where access is restricted or wiring impossible. Password protection provides multilevel access to system controls and can be configured to match operator responsibilities. Event log Up to 1000 alarms, faults and disablements can be displayed or printed in chronological order. Simple design, set up and operation have proved to be the success of the ZP3 on a worldwide basis all made even easier with various user software packages. Planner for Windows enables system designers to fully configure ZP3 systems either directly into the panel via a PC or off site for subsequent download at the commissioning stage. Loop load calculator checks that equipment assigned to any loop is within allowable parameters then calculates power supply requirements. Graphically presenting alarms and events, Maestro provides system control, colour graphics and event logging. Remote diagnosis allows fault diagnosis and information access from remote location via a modem link.

16 GE Security UK Ltd (Ziton) 8 Newmarket Court Chippenham Drive Kingston Milton Keynes England MK10 0AQ Tel: +44 (0) Fax: +44 (0) GE Security South Africa Ltd (Ziton) Ziton House 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax +27 (0) GE Security

17 Ziton ZP Analogue Fire and Smoke Sensors imagination at work

18 Knowing what to expect.... ZP SENSORS SEND INFORMATION TO THE CONTROL PANEL EVERY 2 SECONDS ALGORITHMS IN THE SYSTEM PROCESSING SOFTWARE COMPARE THE INCOMMING ZP SENSOR SIGNALS AGAINST PROFILES ENABLING SENSORS TO DISCRIMINATE AGAINST FALSE OR UNWANTED ALARMS WHILST DETECTING REAL FIRES SOONER. Elegant styling, designed to be unobtrusive, fits perfectly into modern building interiors concealing powerful state of the art electronics. Each sensor type is designed specifically to provide expert detection of temperature rise, products of combustion, smoke or combinations of all three. Based upon tried and tested software and communications and used in thousands of installations throughout the world, the ZP range incorporates the latest components and manufacturing technology. Easily addressed by switch settings, located on the sensor base plate - the unique identification code establishes the device within the system. Up to 127 series ZP sensors can be connected to each loop. All sensors are automatically self tested once every 24 hours and are compensated for calibration changes caused by dirt, temperature, humidity, voltage fluctuations and long term contamination. This maintains every sensor at a constant sensitivity level, allowing even faster fire detection without false alarms. Sensors automatically advise when near maintenance levels have been reached or maintenance is required. Sensitivity can be varied through preset levels, either manually or automatically on a timed basis allowing for example lower sensitivity whilst buildings are occupied during the day, then automatically increased when the premises becomes empty at night time. An important feature, selectable on all smoke sensors, is Alarm Verification enabling the control panel to re-examine incoming fire data prior to making the final alarm decision reducing even further the likelihood of unwanted alarms. Easy to install, all units simply plug into a base with a built in, automatic locking facility. Devices can only be removed by use of a special tool.

19 The ZP sensors ZP710 Ionisation smoke sensor The ZP710 ionisation sensor measures the density of smoke particles in the 0.01 to 10 micron range and provides an active output proportional to the amount of smoke present in the sensing chamber. It is responsive to both visible and invisible products of combustion with very early response to fires in the incipient stage. Dual chamber design provides maximum stability and the device is ideal in risk areas where small particle smoke may be expected for example locations where oil, spirits, wood or paper may be stored. The sensor is fully approved by international certification boards to EN54 Part 7. ZP720 Thermal sensor The ZP720 thermal sensor provides an active output proportional to the ambient temperature. This output value is transmitted to the control panel every two seconds. It is especially useful in areas where environmental conditions may preclude the use of smoke detection. Sensitivity and configuration on an individual sensor basis are set in the control panel and can be adjusted between four levels from 58 o C to 75 o C and includes rate of rise algorithms. The sensor is fully approved by international certification boards to EN54 Part 5. ZP730 Optical smoke sensor The ZP730 optical smoke sensor measures the density of smoke particles in the 0.5 to 10 micron range and provides an active output proportional to the amount of smoke present in the sensing chamber. It is responsive to visible smoke with early responses to smouldering fires. The photo electric principles of operation make it particularly useful where ionisation could prove too sensitive. The sensor s proven stability in air movement, associated with air conditioning systems has made it a popular selection in modern building interiors. The sensor is fully approved by international certification boards to EN54 Part 7. ZP732 Combination smoke and thermal sensor The ZP732 combines optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Individual software control of each element measures actual levels, as well as temperature rate of rise. The sensor is fully approved by international certification boards to both EN54 Part 5 (Class A1 and A2) for thermal performance and EN54 Part 7 for smoke sensitivity. ZX832 Multisensing fire detector Representing the next generation of sensing technology, the ZX832 gives an earlier warning of fire or smoke, with the ability to discriminate against false or unwanted alarms. Software using multi-criteria sensing forms the basis of this advanced device. The detector consists of integrated high sensitivity smoke and thermal sensors. The system combines the dynamic results of rates of change patterns and absolute levels of smoke and heat, to identify real fire criteria. Selectable software algorithms allow the response to be matched to each particular hazard. The sensor is fully approved by international certification boards to both EN54 Part 5 (class A1 and A2) for thermal performance and EN54 Part 7 for smoke sensitivity. The device is also approved within CEA4021 test procedures for multisensor detectors.

20 GE Security UK Ltd (Ziton) 8 Newmarket Court Chippenham Drive Kingston Milton Keynes England MK10 0AQ Tel: +44 (0) Fax: +44 (0) GE Security South Africa Ltd (Ziton) Ziton House 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax +27 (0) GE Security

21 Ziton A series Interface modules GE imagination at work

22 In complete control.... A SERIES MODULES OFFER AN EXTENSIVE RANGE OF CONTROL OPTIONS FOR OPERATING ASSOCIATED EQUIPMENT FROM SIGNALS PROVIDED BY THE FIRE DETECTION SYSTEM BOTH INPUT MODULES AND OUTPUT MODULES CAN BE PROGRAMMED TO ACCEPT OR PROVIDE CONTROL SIGNALS FOR BUILDING MANAGEMENT EQUIPMENT, OTHER FIRE DETECTION FACILITIES OR SECURITY SYSTEMS. The A series range of interface devices has been developed especially to provide control of building systems in the event of fire. Used extensively in installations of all sizes the units enable automatic action for example outputs for shutting down air conditioning plant, or returning elevators to ground level, in fire alarm conditions or inputs receiving incoming signals from other fire protection equipment, for processing and action by the main control panel. Where applicable units comply with the requirements of EN54 Part 18 and have been fully approved by international certification boards. Installed directly onto the fire alarm loop wiring, each module carries it s own unique system address which is scanned by the control panel every two seconds. Used in conjunction with the wide range of analogue addressable sensing devices A series modules can operate either singularly or in groups to provide the most sophisticated cause and effect operations. Fully miniaturised and DIN rail mounted, the range is intended either for installation inside the cabinets of third party control equipment, or housed adjacently using either the ZP7-I/O or the SMB-DIN ranges of enclosures therefore greatly reducing interface cable runs. A45E-2 input module The unit is installed directly onto the ZP loop wiring, carries a system address and enables signals from associated equipment to be interfaced into the fire alarm system. Input signals are fully displayed at the control panel and can be programmed to activate any system output. By routing loop wiring and installing interfaces adjacent to input equipment, system integrity is increased and the need for long, spur wiring between equipment terminals and the fire alarm interface is eliminated. Complying with EN54 Part 18 the A45E-2 can be installed singularly, or used in groups to provide multiway inputs from equipment such as volt free, zonal outputs from conventional fire alarm systems or flow valves from sprinkler installations.

23 A50E-2 relay The A50E-2 is an addressable relay providing single pole, volt free, change over contacts. Complying with EN54 Part 18, the relays can be located anywhere on the two core ZP loop and are designed for power up or shut down of building services, for example air conditioning plant, in fire conditions. The unit is ideal for the control of associated system equipment such as door release circuits, or the emergency shutdown of high risk services, for instance gas or oil supply valves in boiler rooms. A51E mains relay The A51E is an addressable relay providing double pole, volt free, change over contacts, rated to switch local mains supplies. Complying with EN54 Part 18, the relays can be located anywhere on the two core ZP loop and are designed for power up or shut down of the mains electrical supply to ancillary equipment. Popular applications include the control of mains powered system equipment such as magnetic door release circuits, extract fans and dampers. A60E-2 line isolator The A60E-2 line isolator provides short circuit protection, for analogue addressable loop wiring. Isolators are connected at intervals along the length of the loop, dividing the wiring into a series of separate monitored sections. A maximum of 11 isolator units can be connected to each loop, to meet the requirements of EN54 Pt2. In the event of a short circuit wiring fault, isolators disconnect only the section of cable between the two isolators, located electrically closest to the fault. Devices outside the disconnected section continue to operate normally. Open circuit faults are automatically isolated by the control panel, which then operates from both ends running the line as two spurs and retaining full connection to all devices. A70E-2 Conventional Zone interface The A70E-2 zone interface is fully loop powered and enables existing or new conventional zones to be interfaced to an analogue system, allowing all areas of a site to be controlled by the ZP analogue panel. Through its interface, each zone is assigned a unique address, Zones are monitored for fire and fault conditions and status is reported to the ZP control panel every two seconds. A maximum of 127 interface units can be installed on each loop - subject of course to other loop loading. In conjunction with appropriate barrier units the A70E-2 provides a direct loop interface for the DP and DT ranges of intrinsically safe smoke and heat detectors. ZP7-I/O single module box Providing a protective means of surface mounting a single A series module the unit is designed for first and second fix installation. The open back box contains all wiring terminals, modules are clipped to the rear of the front plate and connected by flying leads to the back box terminals. Compatible with A45, A50 and A60 modules. SMB-DIN1 and SMB-DIN2 enclosures Compatible with all A series modules - the SMB-DIN1 accommodates two single width or one double width module and the SMB-DIN2 accommodates four single width or two double width modules. The boxes are pre-fitted with DIN rail for direct mounting of any A series module and are IP66 rated.

24 GE Security UK Ltd 8 Newmarket Court Chippenham Drive Kingston Milton Keynes MK10 0AQ England Tel: +44 (0) Fax: +44 (0) GE Security (Africa) 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax: +27 (0) GE Security (Africa) 27 Angus Crescent Longmeadow Business Park East Edenvale, 1609 PO Box 5078 Edenvale, 1614 Johannesburg South Africa Tel: Fax: GE Security

25 Ziton ZP755 Addressable Alarms imagination at work

26 Alarms for every occasion... DEVELOPED THROUGH WORLDWIDE, ON-SITE EXPERIENCE THE ZP755 ADDRESSABLE ALARM RANGE ENABLES SYSTEM DESIGNERS AND INSTALLERS TO ACHIEVE EXACT ALARM MANAGEMENT AND EVACUATION PROCEDURES IN ANY TYPE OF BUILDING. The ZP755 series is a comprehensive range of advanced addressable sounders, designed for use in ZP3 analogue fire detection and alarm systems. Installed directly onto the ZP loop wiring, ZP755 sounders, in conjunction with the range of Ziton sensors, provide a true two wire system offering full analogue addressable features on a single pair of wires. Installation costs are greatly reduced, whilst system integrity, sounder selection and alarm organisation are significantly increased. Acoustically highly efficient - up to 100 sounders together with 100 sensors can be installed and powered directly on a one kilometre loop - subject of course to wiring specifications. In systems where loop lengths or current requirements are excessive the units can be powered directly from an external power source via dedicated wiring. Installation is simple as all sounders twist and lock into surface base plates eliminating the need for any internal sensor/sounder connections. The range incorporates a number of advanced and unique features Advanced addressing each sounder can operate as a separate device, or in a zone or group, or be linked to a sensor or callpoint enabling individual rooms to be evacuated prior to sounding a general alarm A self test, sound level facility is incorporated into every sounder, monitoring operation by a built in microphone circuit checking for sound output and automatically signaling to the control panel should sound level fall below minimum requirements. Selectable sound outputs, continuous, intermittent and dual tone enable alert and evacuate signals to be provided on a zone, group or individual sounder basis. All three sound types comply with the European standard EN54 Part 3 and the recommendations of most international codes. Tones are synchronized to ensure frequencies are not cancelled out. Horn models feature both wide and narrow angle sound paths providing a full sound dispersion pattern with an evenly balanced output throughout the protected area. ZP755B-2 Sensor base/sounder Combining sensor base and sounder in a single unit. Low current high power acoustic design provides an elegant solution where separate sensor and sounder would prove expensive. The ZP755B is intended for installations involving high numbers of alarm sounders, for example hotel bedrooms or compartmented risk areas. Sensor and alarm elements can be addressed independently and sound levels comply with the requirements of EN54 Part 3. Sound output 90dBA (at 1m), Maximum per 1km loop 60*, Colour white ZP755BV-3 Sensor base/sounder/beacon A sister product to the ZP755B-2 but offering an additional visual output. Complying with most local disability legislation, the unit is also perfectly suited to any location involving high levels of background noise Sound output 90dBA (at 1m), Light source Red LED array, Maximum per 1km loop 40* Colour white moulding red light flash

27 ZP755R-2 Room sounder Compact for areas where the sensor/sounder combination proves impractical for example where fewer or more sounders than sensors are necessary. Applications include lobbies, sleeping accommodation and small rooms and compartments. Sound output 90dBA (at 1m), Maximum per 1km loop 60*, Colour white or red moulding ZP755HA -2 Horn sounder Designed with dual front and rear sound paths, providing an all around sound output - ideal for open area coverage. Continuous, intermittent and two-tone outputs can be selected to provide alert and evacuate two stage alarms. All sound types comply with most international codes for example BS5839 Part1 recommended frequencies. Sound output 102dBA (at 1m), Maximum per 1km loop 40*, Colour white or red moulding. ZP755HAV-2 Horn sounder/beacon Presenting an identical profile to the ZP755HA, the ZP755HAV includes an additional, high intensity beacon. Disability legislation increasingly requires visual alarm signals to ensure equal response from people with hearing impairment - the unit is perfectly suited for this application. The alarm has also proved popular in risk areas involving high levels of background noise. Especially where operators are provided with ear protection. Sound output 102dBA (at 1m), Maximum per 1km loop 25*, Colour white moulding/clear lens or red moulding/red lens ZP755V Addressable beacon Developed to compliment audible alarms, the beacon provides high intensity, visual signals for applications where alarm sounders alone would prove to be ineffective. The unit is designed to meet the requirements of most local disability legislation. Maximum per 1km loop 60*, Colour white moulding/clear lens ZP755W Addressable weatherproof sounder/beacon Ideal for outdoor applications, or for use in areas where the ingress of water can be expected, for example where hygiene requirements demand regular washing or hosing down of equipment within the protected area. Sound output 102dBA (at 1m), Maximum per 1km loop 40*, Colour red moulding. ZP755 WV-2R Addressable weatherproof sounder/beacon A matching unit to the ZP755W but including an additional high intensity beacon. Sound output 102dBA (at 1m). Maximum per loop - 25*. Colour - red moulding/red lens. * Maximum loop populations stated are based on a 1 Km loop of 1.5mm² soft skin cable, with a distance of 50m to the first device

28 GE Security UK Ltd 8 Newmarket Court Chippenham Drive Kingston Milton Keynes England MK10 0AQ Tel: +44 (0) Fax: +44 (0) GE Security (Africa) 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax +27 (0) GE Security

29 Ziton ZR400 Radio Fire Detection Systems imagination at work

30 Seamless integration.... A UNIQUE SYSTEM PROVIDING WIRELESS FIRE DETECTION WITHIN A HARDWIRED INSTALLATION SYSTEMS CAN FEATURE COMBINATIONS OF BOTH TECHNOLOGIES SEAMLESSLY OPERATED FROM A SINGLE CONTROL PANEL ZR400 radio fire detection system fully combines the advantages of analogue addressable technology with wireless operation. It is unique in its ability to seamlessly integrate radio sensors within a hardwired analogue system via the use of ZP radio loop modules. At the core of the system is the loop wired ZP Radio Interface which allows radio devices to be presented as addresses at the main ZP3 fire control panel. Hardwired and radio devices can be mixed on the same loop, provided that the total number does not exceed 127. Two versions of the interface are available The ZP471 is a receive only interface, operating on VHF frequency and designed for connecting sensors and call points. Sounders are hardwired either conventionally or directly onto the ZP loop wiring. The ZP472 receives and transmits, using both VHF and UHF frequencies allowing the connection of the full range of radio based devices, including sounders and interface units. Each sensor, callpoint and sounder is micro processor controlled and is supplied complete with easily replaceable alkaline batteries that ensure in excess of 5 years normal operation all batteries are monitored by the main control panel. The ZR400 range of sensors is fully analogue addressable incorporating such advanced features as adjustable sensitivity, automatic adjustment for contamination, service level reporting and alarm verification feature. Best of both worlds.... Whether the installation is fully or only partly radio with ZR400 - system management, control and indication are identical, regardless of device connection. On site users are unaware of different technologies the system is completely seamless. Even in applications where hard wiring is difficult or building finishes have a high aesthetic importance, for example heritage sites it is rare that the fire detection system warrants total coverage by radio communication. Here the ZR400 proves second to none, providing total design flexibility. Other features include.... Analogue addressable sensors matching appearance and operation to hardwired versions. Receive only or receive and transmit versions provides full option for the inclusion of wireless sounders. Up to 127 radio or hardwired addresses per loop any mixture or combination allowed provided the maximum is not exceeded. Ease of installation ideal for areas where sensor siting and wiring may be costly or where decorative finishes to interiors preclude wiring runs. Complies with current standards EN54, ISO(part15) and BS5839(Part 1). Radio sounder three selectable tones, providing option for completely wireless system. Radio input output unit provides interface for receiving signals from, or controlling equipment associated with the fire detection system.

31 Universal smoke heat and combination sensor Well proven over many years in all applications the ZR432 is a true three in one device not only discriminating against unwanted alarms but sensing real fires faster. The unit is easily set to either optical smoke (four settings) or heat sensor (four settings). With the addition of a combination base the sensor can be configured to optical/heat, featuring a further sixteen smoke/heat combinations each individually based on sophisticated algorithms and covering a range of performances. The sensor has an inbuilt processor that automatically compensates for contamination, provides alarm verification and self test facility. Sensor sounders The ZR420 and ZR430 are stylish combination heat sensor sounder and optical smoke sensor sounder respectively. Analogue addressable, both feature multi state sensing and selectable sensitivity with full device status monitoring of battery pack, contamination levels, head removal and device tamper. The dual battery supply provides two independent power sources, both fully monitored by the control panel. Manual callpoint Featuring aesthetic design The ZR485 callpoint has the same physical dimensions as the hardwired versions. The device has integral batteries, processor, transmitter and aerial. The unit features complete wire free operation and full device status monitoring. Sounder The ZR454 is a battery operated, fully remote, wire free, addressable alarm sounder. Constructed of impact resistance ABS the unit features compact design incorporating a VHF transmitter, UHF receiver, micro processor, sound generator card and battery pack. With an output of 96 dba at 1 metre the device offers four individual sound patterns. The sounder features dual battery supply providing two independent power sources both fully monitored by the control panel. Sounder beacon Providing both alarm sound and visual warning, the ZR454-XN is a powerful device ideal for areas where sound alone would be insufficient for example locations with high levels of background noise, or where premises may be subject to disability legislation - requiring equal response from occupants with hearing impairment. The unit is fully monitored and features dual battery supply from two independent power sources. Input/output unit Designed specifically to monitor the remote operation of fire related equipment for example sprinklers and beam detectors, the ZR451 is ideal for signalling the controlled shut down of building air conditioning and operating the automatic closing of fire doors.

32 GE Security UK Ltd (Ziton) 8 Newmarket Court Chippenham Drive Kingston Milton Keynes England MK10 0AQ Tel: +44 (0) Fax: +44 (0) GE Security Africa Ltd (Ziton) Ziton House 555 Voortrekker Road Maitland 7405 PO Box 181 Maitland 7404 Cape Town South Africa Tel: +27 (0) Fax +27 (0) GE Security

33 Ziton ZP3 System Software GE imagination at work

34 Operation and configuration.... TO BE EFFECTIVE AND PROVIDE MAXIMUM BENEFITS PROJECT DESIGN AND BACK UP NEED TO MAKE FULL USE OF ALL SYSTEM FACILLITIES. ZP3 SOFTWARE PACKAGES ARE DESIGNED TO DO ALL THE HARD WORK- SO THAT YOU DON T HAVE TO. Planner system design The Planner software programme has been developed to provide comprehensive off line configuration of ZP3 Fire Detection and Alarm systems. Simple to use on any suitable PC, Planner features tools for developing systems, ranging from a single stand alone panel, to the largest networked sites. The full range of ZP3 hardware is configurable by the programme, providing the widest scope for system design. Systems featuring hardwired and wireless devices, are easily configured - once the equipment schedule has been completed, system operation is developed using step by - step input/output mapping facilities. Planner verifies that the parameters entered into the databases are within acceptable ranges and automatically prompts the user on allowable options, greatly reducing configuration time whilst increasing system efficiency. New or upgraded versions of operating software, are also transferred to the ZP3 control panel range via the Planner programme, enabling software upgrades to be swiftly completed on site, with a minimum of system downtime. On completion, the configured system software is simply transported to site and downloaded into the control panels via a suitable laptop PC. Main Planner features Comprehensive configuration programme for all ZP3 systems and equipment, from small stand alone panels to largest networked sites Input/output mapping facilities allowing complex cause and effect programmes Automatic input verification prompts user on allowable equipment options Data transfer direct into control panel Comprehensive utilities menu provides a range of programming tools Security protected, access to system via coded password Maestro alarm management and graphic display Maestro is a software package for use on a PC workstation providing system control and information interfaces for ZP3 fire detection and alarm systems. Alarm conditions are displayed graphically, enabling immediate response to any event, even across the largest sites. In addition to alarm management, a wide range of functions can be remotely operated including sounding and silencing alarm warnings, changing control panel settings, enabling and disabling sensors and viewing, recording and printing relevant information on current system status. Based on a system of building maps, the location and type of every device is clearly depicted by a series of icons which change colour or appearance to indicate the current status of all system equipment and the precise location of alarm or fault conditions. Providing easy movement through a variety of map structures - allowing the operator to handle multi alarm

35 situations - a summary of current alarms is clearly displayed on screen at all times. All recorded events can be viewed on the screen and printed to produce a range of event reports. A logbook memo feature makes event response records simple to maintain. All Maestro users are required to log on to the system, under password control. Main Maestro features Graphic alarm display by map, showing site, zone and device Alarm lists showing all current alarms and events categorised by type Information and handling instructions for each alarm Ability to operate fire panels direct from panel fascia shown on the workstation screen Remote disablement and enablement of sensors, sounders and zones Ability to produce reports from historical archive of all events Remote remote location diagnosis The Remote diagnosis programme enables the user to communicate with ZP3 fire control panels from a remote PC, via a modem link. Analogue levels and settings for each device - together with current and archive event logs for any control panel can be viewed. A simulation of the selected control panel fascia, displays current status, with main panel controls accept, reset, sound alarms and silence alarms all able to be operated remotely. System information for example device analogue values can be remotely monitored over a period of time, or listed and printed out prior to site service visits confirming in advance exactly which devices may need attention. Control panel configuration data can be uploaded or downloaded for record or system modification. All system, zone and device messages can be recorded, amended or changed, enabling any equipment location label or zone designation to be altered remotely. Loop load calculator Run off line on any suitable PC, the software provides invaluable assistance for engineers, at loop configuration stages of fire detection and alarm system design. The programme presents each loop as a simple spread sheet, where design quantities of equipment for each loop are entered. Once the loop population has been loaded, the software calculates total current loading, standby periods and battery sizes. The calculator verifies that the device combinations entered into the spreadsheets are numerically acceptable in quantities, compatibility and current consumption whilst automatically prompting the user on allowable options greatly reducing configuration time whilst increasing system efficiency.

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features introduction certified to EN54 parts 2 and 4 The NOTIFIER ID3000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features certified to EN54 parts 2 and 4 expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports

More information

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS (68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

Different types of Fire Alarm System

Different types of Fire Alarm System Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

arm wire free solutions nurse call personal security fire alarms

arm wire free solutions nurse call personal security fire alarms arm nurse call personal security fire alarms arm introduction Radio alarm systems have been serving both the public and private care sector for over a decade. The advances in battery technology, manufacturing

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM INTELLIGENCE EFFICIENCY REFINEMENT INTEGRATION INTUITION Apollo Fire Detectors, the world-leading independent fire

More information

DCS-100. intelligent damper control & monitoring system

DCS-100. intelligent damper control & monitoring system DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls

More information

ID2000. intelligent fire alarm panel

ID2000. intelligent fire alarm panel ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

ZITON RADIO LOOP MODULE

ZITON RADIO LOOP MODULE ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Building Technologies

Building Technologies Building Technologies The safe, sure way to more efficient evacuation: the E100 voice alarm system from Siemens. The safe, sure way to an evacuation system that gets people moving: the E100 from Siemens.

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

FireClass. Introducing a new class of fire detection

FireClass. Introducing a new class of fire detection FireClass Introducing a new class of fire detection Who and what is FireClass? FireClass is a revolutionary new class of commercial fire detection system. Comprising a comprehensive range of fully approved

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

Evacuate everyone Sonos Pulse & Nexus Pulse

Evacuate everyone Sonos Pulse & Nexus Pulse Evacuate everyone Sonos Pulse & Nexus Pulse Available through distribution: www.discountfiresupplies.co.uk Tel: 01792 452 700 EN54-23 Fire Beacons In a fire, everyone matters. Sonos Pulse and Nexus Pulse

More information

Intelligent Addressable Life Safety Systems

Intelligent Addressable Life Safety Systems www.utcfssecurityproducts.eu ZP2 Series Intelligent Addressable Life Safety Systems A practical overview of product highlights and competitive advantages ZP2 series The ZP Family Developed to meet your

More information

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS A Fire detection and alarm ( FD+a ) system is what most workplaces and public accessed buildings have in place. The FD+a system has two primary functions and

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

IQ8Control C Fire Alarm Panel

IQ8Control C Fire Alarm Panel IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means

More information

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23 Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices Approved to EN54-3/EN54-23 Setting the Standard EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

Carephone 52 Security You Can Feel

Carephone 52 Security You Can Feel Carephone 52 Security You Can Feel 2 The Whole Security Range More so than almost any other company, Bosch stands for technical innovations and revolutionary inventions that have changed the world. With

More information

AUTOCALL FIRE DETECTION SYSTEMS.

AUTOCALL FIRE DETECTION SYSTEMS. AUTOCALL FIRE DETECTION SYSTEMS. Autocall delivers technologically superior fire detection systems that are easy to install, simple to service and cost-effective to own. For your customers, that means

More information

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols) Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.) BETTER TO BE SAFE Discovery Analogue Addressable Fire Alarm Panels Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd THE NANO SYSTEM The revolutionary analogue addressable control panel Nano, the revolutionary control panel from Gent Nano is the latest fire detection control panel from Gent by Honeywell. It s a single

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard Pocket guide to Fire Alarm Systems Design BS 5839-1 Standard AVAILABLE TO DOWNLOAD ON THE APOLLO APP The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply!

More information

Fire detection and alarm

Fire detection and alarm Fire detection and alarm Aesthetic Install all cabling and cable containment neatly and unobtrusively, meeting the highest electrical industry installation standards. Neatly lay and securely fix cables.

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

Apollo Accreditation. Need further information? Visit

Apollo Accreditation. Need further information? Visit Product Catalogue 2016/2017 Apollo Accreditation Apollo products are certified in a global arena to meet the most exacting standards set by both our customers, and the dynamic and challenging environments

More information

LaserFOCUS VLF-250 Engineering Specification

LaserFOCUS VLF-250 Engineering Specification Vision Fire & Security LaserFOCUS VLF-250 Engineering Specification May 2004 Part Number 20296 LaserFOCUS VESDA 2 VESDA LaserFOCUS Contents Scope...4 Description...4 General...4 Approvals...4 Codes, Standards

More information

All the security you need in one housing

All the security you need in one housing IQ8Quad All the security you need in one housing IQ8Quad: The highlight of every fire detection scenario Fire detection technology 02 03 Safety is the result of efficiency and innovation This applies to

More information

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings GE Security EST Fire & Life Safety Sophisticated io-series Intelligent Life Safety Systems for small to mid-size buildings io Series Supports Signature Series intelligent detectors and modules Electronic

More information

Why Hart XL Aspirating Smoke Detection?

Why Hart XL Aspirating Smoke Detection? HART XL Why Hart XL Aspirating Smoke Detection? Earliest detection to enable business continuity Extra time is required for safe evacuation Unnecessary suppression release must be avoided Smoke is difficult

More information

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n The Genesis Wireless PIR System BS8418 Compliant S e t t i n g n e w s t a n The Genesis Wireless PIR System BS8418 compliant The GENESIS

More information

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation four fire safety tasks, one device l This applies to fire alarm systems too,

More information

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Operating instructions SENTRI4 Control panel based Fire detection and alarm system 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 30 32 Zones Healthy 15:45 Fault Power Fault System Fault SenTRI 4 Fire System Designed to EN54 Pt 2 & 4 Operating instructions

More information

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM Revision 2: November 1998 INDEX 1. SCOPE 2. GENERAL DESCRIPTION 3. STANDARDS 4. SYSTEM OPERATION 4.1 ACCESS LEVELS 4.2

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

MINERVA MZX125. Digital Addressable Fire Detection System

MINERVA MZX125. Digital Addressable Fire Detection System A C C E S S C O N T R O L C C T V E A S R F I D F I R E P R O T E C T I O N I N T R U D E R A L A R M S DATA SHEET MINERVA MZX125 Digital Addressable Fire Detection System Features: Long term service and

More information

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS An EVCS (emergency voice communication system) or Disabled Refuge System is designed for use in buildings that contain refuge areas. This type of intercom system

More information

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10. FIRE DETECTION : FIRE SUPPRESSION EMERGENCY VOICE COMMUNICATIONS SYSTEM INTEGRATION ACCLAIM SERIES 10 s Building the system you need ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible choices from

More information

/ / White Paper. Focusing on user experience

/ / White Paper. Focusing on user experience / / Tyco Fire Protection Products is a leading manufacturer of fire detection, suppression and protection solutions. Here, it examines how to ensure effective use of fire detector control panel technology

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

GE Security. Proven. Powerful. Integrated fire and life safety solutions.

GE Security. Proven. Powerful. Integrated fire and life safety solutions. GE Security Proven. Powerful. Integrated fire and life safety solutions. Why choose a GE fire & GE is with you all the way. GE design and manufacture the total fire technology solution. GE can integrate

More information

Analogue Detectors. Series 200 plus

Analogue Detectors. Series 200 plus Analogue Detectors Series 200 plus The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m 2 state-ofthe-art facility in Trieste,

More information

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series Instruction Manual Read and retain carefully for as long as the product is being used. It contains

More information

Fire detection and alarm system Operating instructions

Fire detection and alarm system Operating instructions Fire detection and alarm system Operating instructions Operating instructions Table of Contents User responsibility - - - - - - - - - - - - 4 Daily - - - - - - - - - - - - - - - - - - - 4 Weekly - - -

More information

Innovative protection that combines power and flexibility

Innovative protection that combines power and flexibility Innovative protection that combines power and flexibility Desigo Fire Safety Modular outpaces industry standards and includes cutting-edge detection and communication capabilities usa.siemens.com/desigo-fs-modular

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE CAUTION

More information

Sensors (All Fully Customisable)

Sensors (All Fully Customisable) SafeGuard Safe Guard modular Wireless GSM Sensors and Detectors Compact GSM Wireless Alarm System Sensors (All Fully Customisable) Security Fire Smoke / Gas Flooding Chemical Temperature Eco Battery Up

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection

More information

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Operating instructions Vigilon panel and Network node Fire detection and alarm system Healthy 15:45 Fault Power Fault Vigilon Fire System GENT 2015 Designed to EN54 Pt 2 & 4 System Fault Operating instructions Vigilon panel and Network node Fire detection and alarm system Test Fire Fault/Dis

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY S I G N A T U R E S E R I E S WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE.... EST LIFE SAFETY PRODUCTS...... DETECTORS AND MODULES... EDWARDS SYSTEMS TECHNOLOGY TM SIGNATURE SERIES LIFE SAFETY DEVICES.

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations AutroSafe interactive fire detection system AUTROSAFE An interactive fire detection system for complex installations AUTROSAFE AutroSafe interactive fire detection system is designed to meet the toughest

More information

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology IQ8Quad The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation l This applies to fire alarm systems too, as especially in this case,

More information

EMERGENCY ASSISTANCE ALARMS

EMERGENCY ASSISTANCE ALARMS Folknoll Group Ltd. EMERGENCY ASSISTANCE ALARMS BS 8300:2009 AND DOCUMENT M COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx

More information

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS CONTENTS 1. System Overview 2. User responsibilities 3. First Line controls and indications 3.1 Logging on to the fire alarm system 3.2 Checking system status

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

CONVENTIONAL AUDIBLE VISUAL

CONVENTIONAL AUDIBLE VISUAL Fast Installation, Safe Evacuation CONVENTIONAL AUDIBLE VISUAL www.kac.co.uk Setting the Standard with ENscape EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm Devices

More information

Security Escort. boschsecurity.com. Reliable wireless location solutions

Security Escort. boschsecurity.com. Reliable wireless location solutions Security Escort boschsecurity.com Reliable wireless location solutions Security Escort Overview What is Security Escort? Security Escort is a wireless help-call system that allows you to locate people

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and

More information

WG Buried Cable Perimeter Detection System

WG Buried Cable Perimeter Detection System Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Cable Perimeter Detection System The WG Cable Detection Sensor is a covert outdoor perimeter

More information

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology. Cerberus PRO intelligent fire protection A comprehensive portfolio of innovative and industry-leading technology www.usa.siemens.com/cerberus-pro Cerberus PRO the comprehensive fire protection system Intelligent

More information

AUTROSAFE. An interactive fire detection system for larger vessels

AUTROSAFE. An interactive fire detection system for larger vessels AUTROSAFE An interactive fire detection system for larger vessels AUTROSAFE AutroSafe interactive fire detection system is designed for the toughest requirements and expands the possibilities of a fire

More information

Vigilant MX4428 Fire Alarm System

Vigilant MX4428 Fire Alarm System Vigilant MX4428 Fire Alarm System The Vigilant MX4428 is an intelligent fire alarm system, incorporating Tyco MX TECHNOLOGY to provide advanced, analogue addressable fire detection. It features support

More information

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network Protec Protec Fire Detection plc Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

More information

Modular Fire Panel 5000 Series Just as flexible as your plans

Modular Fire Panel 5000 Series Just as flexible as your plans Modular Fire Panel 5000 Series Just as flexible as your plans 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market: With

More information

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide. Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production

More information

Wireless Fire & Security Solutions. Fire Product Showcase

Wireless Fire & Security Solutions. Fire Product Showcase Wireless Fire & Security Solutions Fire Product Showcase 2 Contents Contents 3 FireCell Overview 4-5 Taktis Control Panel Overview 6 Taktis Control Panels & Accessories 7-8 Syncro AS Control Panel Overview

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47

More information