Product training FLIR K series for firefighters(k45, K55, K65)

Size: px
Start display at page:

Download "Product training FLIR K series for firefighters(k45, K55, K65)"

Transcription

1 Product training FLIR K series for firefighters(k45, K55, K65)

2 Disclaimer Dear Student, We kindly ask you to read the following carefully. Copyright ITC All rights reserved. This training material must not, in the whole or part, be copied, photocopied, reproduced, translated or transmitted to any electronic medium or machine readable form without the prior written permission of ITC. Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property or their respective owners. Legal disclaimer ITC s course material has been put together with highest diligence and according to the recognized state of the art within the field of thermography and its applications. Neither FLIR Systems nor ITC shall be liable for any direct, indirect, special, incidental or consequential loss or damage caused by eventual printing errors, changes of technology, standards and guidelines, or misinterpretations of the participant. Note/Advise Please be aware that infrared inspections of any kind- including IR image and other data acquisition, analysis, diagnosis, prognosis and reporting is a highly advanced skill. It requires professional knowledge of thermography and the specific application field, and is, in some countries, subject to certification and also legislation. Consequently, we strongly recommend that you seek the necessary training before carrying out inspections. Please visit the following sites for more information: Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

3 Content About the camera How a thermal camera works Specifications Component parts Battery Operate the buttons Screen elements, menus, and functions Camera operation Select between the modes Freeze, save, and recall images Record and view videos Change settings ConnectthecameratoaPC Change settings with FLIR Tools Transfer files Test questions - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

4 Sensing heat Whenclosetoawarmorhotobject,wecanfeeltheheatonourskin. Thedetectorofathermalcameraisalsosensitivetoheat. An electrical signal is generated and transformed into a thermal image. Figure 1 Camera principle - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

5 The thermal camera InthethermalimageoftheKseriescameras,darkermeanscolder and brighter means hotter. Figure2Twoexamplesofhowthethermalcameraseesheat - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

6 Technical specifications <1.1 kg 2mdroptested Water resistant(to IP67) Infrared resolution: K45: pixels K55andK65: pixels 60 Hz frequency Fieldofview(FOV):51 x38 2 digital zoom Two temperature ranges: 20 to +150 C(high sensitivity mode) 0 to +650 C(low sensitivity mode) Five camera modes Spotmeter, isotherm, and FSX Figure 3 K series cameras technical specifications - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

7 Specifications infrared resolution FLIR K45 ( ) Instantaneous FOV(IFOV)(at 1 m) 3.7 mm 2.9 mm 5 IFOV(at1m) 1.85cm 1.45cm Distancetoseeacat(20cmtall) 10m 14m Distancetoseeahuman(1.8mtall) 100m 125m Distancetoseeanelephant(4mtall) 200m 250m FLIR K55/K65 ( ) Figure 4 The practical implication of infrared resolution - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

8 Specifications infrared resolution At pixels (FLIR K55 or K65) you can recognize a human at a distance of up to 100 m. Figure 5 Recognizing two persons - Product training FLIR K series for firefighters (K45, K55, K65) Publ. No. T560489_35773_en-US_

9 Specifications field of view Normally our field of view(fov) is TheKseriescameralimitstheFOVto50. Figure 6 How the FOV affects your sight. Image credit: IRIS Thermovision. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

10 Specifications image frequency 60 Hz faster than the eye. True real-time information. Gives a fast, immediate overview of the situation, allowing fast action. Figure 7 Falling droplets seen with a thermal camera - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

11 Specifications FSX The K series cameras are equipped with FSX(Flexible Scene Enhancement): FSX is an advanced non-linear image-processing algorithm. FSX preserves detail in high dynamic range images. FSX extracts image details, such as edges and corners, from the original image. These details are weighted and combined with the original image. The result is an image with enhanced detail. Figure 8 Left: Image without FSX. Right: Image with FSX - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

12 Component parts FLIR K45 and K55 1. USB Mini-B connector. 2. Attachment point for the lanyard strap. 3. Eccentric latch to secure the battery. 4. On/off button. 5. Mode button. 6.Accesstosetupmenusandstoredimages:Push Mode + Zoom buttons. 7. Zoom button. 8. Connectors for the in-truck charger. 9. Save trigger. 10.Mount for a tripod adapter. 11.Attachment point for the retractable lanyard. 12.Battery. Figure9ComponentpartsoftheFLIRK45andK55 - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

13 Component parts FLIR K65 1. USB Mini-B connector. 2. Attachment point for the lanyard strap(left and right sides). 3.Latchtosecurethebattery(fastenedwithaTorx T20screw). 4. On/off button. 5. Mode button. 6.Accesstosetupmenusandstoredimages:Push Mode + Zoom buttons. 7. Zoom button. 8. Connectors for the in-truck charger. 9. Save trigger. 10.Mount for a tripod adapter. 11.Attachment point for the retractable lanyard. 12.Battery. Figure10ComponentpartsoftheFLIRK65 - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

14 Component parts battery Howtoremovethebatteryofthe FLIRK45andK55: Pull the eccentric latch. Pull out the battery. Howtoremovethebatteryofthe FLIR K65: Unscrew the Torx T20screwandpull the latch. CAUTION Donotuseatorquevalueof morethan80ncmforthe Torx T20 screw. Damage to thecameracanoccurifyou disregard this. Pull out the battery. Figure 11 Remove the battery - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

15 Charge the battery Standalone battery charger 1. Put the battery into the standalone battery charger. 2.Connectthepowersupplycableplugto the connector on the standalone battery charger. 3. Insert the power supply mains electricity plug into a mains socket. 4. Disconnect the power supply cable plug when the blue battery condition LED glows continuously. In-truck charger(optional accessory) 1.Pushthebatteryintotheslotatthelower front of the charger. 2. Secure the battery using the eccentric latch on the charger. 3.Chargingofthebatteryhasnowstarted andiscompletewhentheblueled glows continuously. NOTE The camera can also be charged directly without removing the battery using the in-truck charger. Chargethebatteryfor4hoursbeforestartingthecameraforthefirsttime,oruntilthe blue battery condition LED glows continuously. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

16 In-truck charger The in-truck charger allows the battery to be charged both when inside the camera and when removed. Thein-truckchargerisintendedtobemountedonaflatsurfaceinthecab,inone of the equipment lockers, or in another suitable compartment of the fire engine. Figure 12 In-truck charger - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

17 In-truck charger 1. Top cover. 2. LED indicator for the camera charger. 3. Hole for attaching the charger housing to the metal bracket. 4. Connectors in the cradle. 5.Connectortopowerthechargerusinga standard FLIR Systems power supply. 6. Hole for attaching the charger housing to the metal bracket. 7. LED indicator for the battery charger. 8. Battery slot. 9. Eccentric latch to secure the battery during charging. Figure 13 In-truck charger: Front view - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

18 In-truck charger 10.Cable port. 11.Routing support V DC cable plinth. 13.Recess for the cable. 14.Routing support. For recommended cable areas and the fuse, and the mounting instructions, refer to the camera s user s manual. CAUTION Disconnect the in-truck charger from the fire engine s V DC system before cleaning. The in-truck charger can be cleaned using warm water or a weak detergent solution. Do not use solvents or similar liquids. Figure 14 In-truck charger: Rear view - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

19 Camera buttons 1. On/off button a. Pushtoturnonthecamera. b. Pushandholdformorethan3seconds butlessthan10secondstoputthe camera into standby mode. c. Pushandholdformorethan10seconds toturnoffthecamera. 2. Mode button Push repeatedly to select camera modes. 3. Zoom button Zoom factor 2. 4.Push the Mode and Zoom buttons simultaneously to access setup menus and stored images. Figure 15 Camera buttons - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

20 Save trigger and lens 1. Save trigger a. Pull:Saveanimage. b. Pullandhold:Animageisfrozenuntil thetriggerisreleased.oravideois recorded. Use the Change settings menu in FLIR Toolstoenablefreezingofanimageor video recording. 2. Lens Figure 16 Save trigger and lens - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

21 Prior and after use Check the following before using the camera: 1. Make sure that the battery is inserted correctly. 2.Switchonthecamera. 3.Waitfortheimagetobedisplayed. 4. After a small click is heard(indicating the NUC(non-uniformity correction)), the cameraisreadytouse. 5. You can also toggle through the modes or check the digital temperature reading. Do the following after using the camera: 1.Switchitoff. 2.Cleanthecamerahousingwitheitherwarmwateroraweakdetergent,appliedtoa soft cloth. 3.Cleanthelenswitheither: a commercial lens-cleaning liquid with more than 30% isopropyl alcohol or 96%ethylalcohol(C 2 H 5 OH)appliedtocottonwool. 4. Charge the battery. 5.TransferimagesandvideoclipstoaPC,ifneeded. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

22 Screen elements 1. Basic mode. 2. Black and white firefighting mode. 3. Fire mode. 4. Search and rescue mode. 5. Heat detection mode. 6. Low-sensitivity indicator. 7. Overheating indicator. 8. Indicator symbol for change in the color reference. 9. Reference bar. 10.Temperature bar. 11.Spotmeter temperature. 12.Battery condition indicator. 13.Spotmeter. Figure17ScreenelementsfortheFLIRKSeries - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

23 Temperature measurement Figure 18 Incorrect temperature measurement of flames - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

24 Camera modes The K series cameras have five modes for different purposes and tasks. Figure 19 The five different camera modes They differ in the use of temperature ranges and heat colorization. Temperature ranges: Low sensitivity: 0 to +650 C(observe the indicator to the upper left). High sensitivity: 20 to +150 C. Modes with green icons: Automatic range selection. Modes with blue icons: Temperature range is locked to high sensitivity. Heat colorization: Above a certain temperature, colors are used to visualize intervals of higher(and equal) temperatures. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

25 Temperature range Low sensitivity: 0 to +650 C. High-temperature details are visible. High sensitivity: 20 to +150 C. Low-temperature details are visible. For different types of operation, one temperature range will be more suitable than the other. Figure 20 Low- and high-sensitivity range - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

26 Heat colorization Thermal images from the K series cameras use a grayscale. Heat colorization adds information about temperature. Above a threshold temperature, one or more colors are added. The additional color(s) allows hot spots or areas to be localized faster and more precisely: a. Threshold temperature. b. Lower-temperature range limit. c. Upper-temperature range limit. d. Maximum temperature in the scene. e.hottestareas:20%ofthescene. Figure 21 Principle of heat colorization - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

27 Heat colorization a. Grayscale image: Intuitive and simple image. Some details. b. Heat colorization with several colors: Region of interest showing a lot of detail. c. Heat colorization with one color: Extremely obvious location of the hottest region No details for high temperatures. Figure 22 Different types of heat colorization - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

28 Basic mode Initial fire attack with life-saving procedures and controlofthefire Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: +150 to +650 C. Figure23Exampleforthebasicmode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

29 Black and white firefighting mode Initial fire attack with life-saving procedures and control of the fire. Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: None. Black and white is more intuitive than a color palette. Figure 24 Example for the black and white firefighting mode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

30 Fire mode Initial fire attack with life-saving procedures and control of the fire. Suitable for higher background temperatures. Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: +250 to +650 C. Figure25Exampleforthefiremode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

31 Search and rescue mode Situations with lower temperatures. High-sensitivity range, locked: 20 to +150 C. Colorization of heat: +100 to +150 C. The blue Temperature bar indicates the temperature at the spot meter. Figure26Exampleforthesearchandrescuemode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

32 Heat detection mode Searching for hot spots and thermal patterns in colder environments. High-sensitivity range, locked: 20 to +150 C. Colorization of heat: The hottest areas of the viewed scene(20% of total view). Dynamic indication. The blue Temperature bar indicates the temperature at the spot meter. Figure 27 Example for the heat detection mode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

33 Freeze and save images Save an image: Pull the Save trigger. Freeze an image: Pull and hold the Save trigger. Record a video: Pull and hold the Save trigger. Youcansaveamaximumof200imagesin the archive. A frozen image is easier to analyze because itisnotmoving. Youcaneitherfreezeanimageorrecorda videobyholdingthesavetrigger.usethe Settings menuorflirtoolstoselectthe function. Figure 28 Save trigger functions - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

34 Recall images Enter the image archive: 1.Pushthe Modebuttonandthe Zoombuttonatthesametime. 2.Pushthe Modebuttontoenterthe archive. In the archive: 1.Pushthe Modebuttontomove forward through the images. 2.Pull the Save trigger to move backward through the images. 3.Pushandholdthe Zoombuttonto enlarge an image. 4.Pushthe On/offbuttontoexit the archive. Figure 29 Archive - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

35 Viewing saved video clips Enter the archive: 1.Pushthe Modebuttonandthe Zoombutton atthesametime. 2.Pushthe Modebuttontoenterthearchive. In the archive: 1.Videoclipsareindicatedbyafilmstripicon. 2.Pushthe Modebuttontomoveforward through the videos. 3.PulltheSavetriggertomovebackward through the videos. 4.Pushandholdthe Zoombuttontostart viewing a video. 5.Releasethe Zoombuttontostopviewinga video. 6.Pushthe On/offbuttontoexitthearchive. Figure 30 Viewing video clips - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

36 Camera settings Enter the Settings menu: 1.Pushthe Modebuttonand the Zoom button at the same time. 2. Push the Zoom button to display the Settings menu. In the Settings menu: 1. Push the Mode button to step forward. 2. Push the Zoom button to change a value. 3.Pushthe On/offbuttonto confirm and exit. Figure 31 Settings menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

37 Temperature indication Basic mode with Reference bar Fire mode with Temperature bar Heat detection mode with Digital read-out (measurement) a. Reference bar b. Temperature bar c. Digital read-out (measurement) Figure 32 Examples of temperature indication in different modes - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

38 ConnectthecameratoaPC FLIRK45andK55 1.Folduptherubbercoveratthe topofthecamera. 2.Holdthemetalringfirmly. 3. Rotate the ring approximately 110 counter-clockwise. 4. Pull out the plastic insert. CAUTION The plastic insert has an O-ring seal.donotdamagethisseal. 5.ConnecttheUSBcabletothe USB Mini-B connector in the connector bay. Figure33ConnectaFLIRK45orK55toaPC - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

39 ConnectthecameratoaPC FLIRK65 1.Folduptherubbercoveratthetopof the camera. 2.Foldupthemetalring. 3.UnscrewtheTorxT20screw. CAUTION Makesurethatyoudonotuseatorquevalueof morethan80ncmforthetorxt20screw.damage tothecameracanoccurifdisregardthis. 4. Pull out the plastic insert. CAUTION TheplasticinserthasanO-ringseal.Donot damage this seal. 5.ConnecttheUSBcabletotheUSB Mini-B connector in the connector bay. Figure34ConnectaFLIRK65toaPC - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

40 File transfer Drag and drop FLIR Tools Figure 35 Two options for image transfer - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

41 FLIR Tools 1. Change K series camera settings. 2. Import images from the camera. 3.Viewimagesinthelibrary. 4.Connecttoalivestream. 5. Create reports. 6. Update the camera. Figure 36 Using FLIR Tools - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

42 Changing camera settings in FLIR Tools General Settings tab 1. Regional settings: Synchronize the camera s date and time settings with the computer. 2. Firmware info area: Check for a newer version of the camera firmware. 3. Restore to factory default area: Restore all camera settings to the factory defaults. Figure 37 General Settings menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

43 SetuptheuserinterfacewithFLIRTools User interface tab 1. Temperature unit area. 2. Thermal indication area, select between: Digital readout only Reference bar Temp bar. 3. Save-button long press area. No action. Freeze image. Record video. 4. Auto range: The camera will automatically switch between the high-sensitivity range and the low-sensitivity range. 5. Add custom boot image. Figure 38 User interface menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

44 Camera operation Exercises Do the following exercises: 1. Remove(charge if needed) and insert the battery. 2.Switchthecameraonandoff. 3. Toggle the camera modes. 4.Ineachmode,observethethermalimagewhenlookingatobjectswith different temperatures. 5. In the Settings menu, change the temperature indication and observe the reference bar, the temperature reading, and the temperature bar for each mode. 6. Freeze, save, and recall images. 7.Recordandviewavideoclip. 8. Transfer images. 9. Create a simple report. 10.Clean the camera, and also the lens. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

45 Test questions 1.Whichofthefollowingliquidsshouldbeusedtocleanthecamerahousing? a. Common solvents. b. 96% ethyl alcohol. c. Warmwater. d. 50% acetone plus 50% ethyl alcohol(by volume). 2.Whatistheapproximatemaximumdistanceatwhichyoucanseeahuman beingusingaflirk45camera? a. 500m. b. 100m. c. 850m. d. 225m. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

46 Test questions 3. When would you prefer to use the high-sensitivity range? a. When the background temperature is high. b. Whenlookingforrelativelycoolobjectsinacoldenvironmentandthereisaneed to resolve small temperature differences. c. When dealing with large heights. d. Whenlookingforveryhotobjectsinacoldenvironment. 4.Inwhichsituationwouldyouusetheheatdetectionmode? a. Searching for persons in a smoke-filled room. b. Looking at a structural fire. c. Lookingforthermalpatternsontheseatsofacarafteranaccident. d. During the initial fire attack. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

47 Test questions 5. Using modes with heat colorization, what will you see with the thermal camera when the temperature is above the maximum temperature of +150 or +650 C? a. Saturation will occur, and saturated pixels will be displayed in purple. b. Heat colorization will stretch over the entire reference bar. c. The display will turn black. d. Thecamerawillswitchoff. 6.Whycanathermalcameraseeheat? a. BecauseitissensitivetoXrays. b. Becauseithasafrequencyof60Hz. c. Because the detector is sensitive to infrared radiation. d. Becauseithasaresolutionofatleast pixels. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

48 Test questions 7. What happens when infrared radiation travels through gases? a. It disappears. b. Itbecomesvisibletooureyes. c. It is unaffected. d. It is partly absorbed. 8.Howcanyouseethepreviousimageinthecameraarchive? a. By pushing the Save trigger. b. Bypushingthe Modebutton. c. By pushing the Zoom button. d. By pushing the On/off button. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

49 Test questions 9. Which of the following statements is true? Heat colorization a. overlays certain intervals of(equal) temperature with one or more contrasting colors. b. changes the temperature in the thermal image. c. depends on the object you are looking at. d. works only in closed environments. 10.Why can we look through smoke with a thermal camera? a. Because smoke is moving rapidly. b. Because smoke is essentially transparent to infrared radiation. c. Because smoke is lightweight. d. Because smoke mostly is warm. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

50 Learn more know more ITC is the leading source within infrared science and its applications. To learn more, visit our website, take our online trainings, or attend a traditional face-to-face class. ITC EMEA websites and course calendar: ITC Americas websites and course calendar: Global ITC course schedule: ITC online training: - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_

Dräger UCF 7000 Thermal Imaging Camera

Dräger UCF 7000 Thermal Imaging Camera Dräger UCF 7000 Thermal Imaging Camera Today, any call could potentially bring you into a hazardous area. The Dräger UCF 7000 thermal imaging camera is intrinsically safe and offers new levels of security

More information

SEE THROUGH SMOKE FROM EVERY ANGLE. FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting

SEE THROUGH SMOKE FROM EVERY ANGLE. FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting SEE THROUGH SMOKE FROM EVERY ANGLE FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting IMAGE MODES FLIR THERMAL IMAGING CAMERAS FOR FIREFIGHTING FULL FORCE COVERAGE FROM THE GROUND

More information

BULLARD T4MAX THERMAL IMAGER CAMERA

BULLARD T4MAX THERMAL IMAGER CAMERA BULLARD T4MAX THERMAL IMAGER CAMERA OBJECTIVES IDENTIFY ALL COMPONENTS & FEATURES OF BULLARD T4MAX DEMONSTRATE USES AND APPLICATIONS DISCUSS CARE AND MAINTENANCE DISCUSS OPERATIONAL CAPABILITIES & LIMITATIONS

More information

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, AVIGILON CONTROL CENTER,

More information

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2017, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACC, AVIGILON CONTROL CENTER,

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with

More information

CS027 User Instructions

CS027 User Instructions CS027 User Instructions Battery Powered 7 Day Programmable Room Thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. The CS027 programmable

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this

More information

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature Model: 616-146v2 Quick Setup Guide DC: 090116 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor

More information

Mood Light and Nature Sound Alarm Clock

Mood Light and Nature Sound Alarm Clock Mood Light and Nature Sound Alarm Clock For online video support: http://bit.ly/laxtechtalk Model: C83117 DC: 031518 TABLE OF CONTENTS 3 3 4 4 4 4 5 5 5 6 6 6 6 7 7 7 7 8 8 9 9 9 9 10 10 Power Up Settings

More information

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock BUTTONS Model: 616-146Av2 Quick Setup Guide DC: 111815 Atomic Projection Alarm Clock Snooze/Backlight Time, Alarm with Snooze Projection Arm Rotates 180 Indoor Temperature + Trends Moon Phase + Calendar

More information

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide 8200-1102-10 B0 Notice Please read this manual thoroughly and save it for future use before attempting to connect or operate this

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

Engineering Specification

Engineering Specification Engineering Specification Page 1 of 8 Contents PURPOSE AND SCOPE...3 VERSION HISTORY...3 GENERAL...4 DESCRIPTION OF WORK... 4 VIDEO SMOKE DETECTION CENTRAL EQUIPMENT...5 CENTRAL CONTROL UNIT... 5 SYSTEM

More information

Your competent partner for measuring and services.

Your competent partner for measuring and services. Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the

More information

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL - WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM10 - - OWNER S MANUAL - Thank you for purchasing the new generation of color projection clock. Designed and engineered

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center Control Center Prerequisite: IndigoVision Control Center 4.7 build 25 or later Sightlogix Firmware: 5.4.6829 or later Control Center Note: This functionality is only available if you have administrator

More information

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

High Precision Digital Rain Gauge with Indoor Temperature and Humidity High Precision Digital Rain Gauge with Indoor Temperature and Humidity Contents 1. Introduction... 2 2. Get Started... 2 2.1 Parts List... 2 2.2 Recommend Tools... 3 2.3 Installation... 3 2.4 Mount outdoor

More information

HDCVI PIR Camera User s Manual

HDCVI PIR Camera User s Manual HDCVI PIR Camera User s Manual Version 1.0.1 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Detection Range... 4 4 Device Installation... 5

More information

Colour Observation System

Colour Observation System FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3

More information

JOVY SYSTEMS RE-7500 User Manual Rev Index

JOVY SYSTEMS RE-7500 User Manual Rev Index JOVY SYSTEMS RE-7500 User Manual Rev. 1.60 Index - Introduction... 3 - Copyrights and Liability disclaimer........ 3 - Specifications.. 4 - Safety/ Caution instructions...... 4 - RE-7500 hardware description......

More information

USER MANUAL USB Multi-Function Datalogger Model RHT35

USER MANUAL USB Multi-Function Datalogger Model RHT35 USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable

More information

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure. Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

System Description AutroMaster V Presentation System

System Description AutroMaster V Presentation System System Description AutroMaster V Presentation System AMASTERV-SYSTEM/XGB, Rev. B, 2018-05-07, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,

More information

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0 Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH

More information

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock BUTTONS Model: 616-146A Quick Setup Guide DC: 070314 Atomic Projection Alarm Clock Snooze/Backlight FRONT VIEW Time, Alarm with Snooze Projection Arm Rotates 180 Indoor Temperature + Trends Moon Phase

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location Model: T83653v2 Instruction manual DC: 012916 WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location FRONT VIEW Time, Alarm + Calendar Indoor Humidity & Temperature

More information

CORAL MANTA User Guide

CORAL MANTA User Guide CORAL MANTA User Guide Copyright 208 Coral Detection Systems, all rights reserved. Rev B Doc P/N: xxxx 2. Contact Information For help with this device, please contact Coral Detection Systems at: Website

More information

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes DEFECTOVISION IR Non-Destructive Testing of Steel Billets and Tubes FOERSTER DIVISION TESTING SYSTEMS (TS) The Company FOERSTER is a global technology leader for nondestructive testing of metallic materials.

More information

Precision Infrared Thermometer. Users Manual

Precision Infrared Thermometer. Users Manual Precision Infrared Thermometer Users Manual March 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev2 Copyright 2011 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules. English FCC declaration Warning: To prevent fire or shock hazard, do not expose camera or monitor to rain or moisture. The lightning flash with arrowhead symbol, within a triangle, is intended to alert

More information

CAN unit for Analog Sensors

CAN unit for Analog Sensors CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Picture Perfect 4 INT-PP4-A-Rev1 Copyright 2012 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

Atomic Projection Alarm Clock

Atomic Projection Alarm Clock Model: 616-143 Quick Setup Guide DC: 072915 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) FRONT VIEW Buttons Projection Focus BACK VIEW AC Power

More information

Milestone XProtect Alarm Matrix Integration 1.0

Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Target Audience This document is aimed at system users and provides descriptions on how to install, configure

More information

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide GE Security TruVision Bullet IR Camera Pocket Guide g 1065696A Copyright Disclaimer Trademarks and patents Intended use Copyright 2008 GE Security. All rights reserved. This document may not be copied

More information

Datasheet Crowd Management

Datasheet Crowd Management Datasheet Crowd Management Version 3.78 This Specification Sheet gives the details of system requirements, feature details and other salient points of AllGoVision s Crowd Management applications. Revision

More information

PROFESSIONAL DRIVER FATIGUE MONITOR

PROFESSIONAL DRIVER FATIGUE MONITOR PROFESSIAL DRIVER FATIGUE MITOR RVS-350P User Manual Product Composition *RVS-350P includes the host and 5 pin signal line. It can work on all types of vehicle, both 12V and 24V power supply. Caution Do

More information

Security Management System - Configuring Video Analytics

Security Management System - Configuring Video Analytics Introduction This document describes the steps for configuring the Video Analytics (VA) module available in the Security Management System software. Security Management System video analytics module is

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

Typical applications include the vibration detector. Detection of vibrations and shocks

Typical applications include the vibration detector. Detection of vibrations and shocks Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

Outdoor Temperature Sensor

Outdoor Temperature Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight Model: 616-143 Quick Setup Guide DC: 083017 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) Buttons Projection Focus 5.0 VAC Power Jack 616-143 www.lacrossetechnology.com/support

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

HDAVS ICR IR Water proof Dome Camera User s Manual

HDAVS ICR IR Water proof Dome Camera User s Manual HDAVS ICR IR Water proof Dome Camera User s Manual Version 1.0.0 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Installation... 3 4 Menu...

More information

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide GE Security TruVision Bullet IR Camera Pocket Guide EN FR DE IT NL ES PT PL g 1065697A Copyright Disclaimer Trademarks and patents Intended use Copyright 2009 GE Security. All rights reserved. This document

More information

Owner s Manual. PIR-1 IR Learner

Owner s Manual. PIR-1 IR Learner Owner s Manual PIR-1 IR Learner PIR-1 Owner s Manual 2010-2013 Universal Remote Control, Inc. The information in this owner s manual is copyright protected. No part of this manual may be copied or reproduced

More information

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title WiFi Hints & Tips Contents Page No. Section No. Title Section.0 System Set-Up 3 Section. Sensor Set-Up 4-5 Section. Sensor Set-Up (Configuring Network) 6-9 Section.3 Sensor Set-Up (Configuring Settings)

More information

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc. Millennium Xtra Millennium ATMA setup and configuration guide May 16 2017 Millennium Group, Inc. 16 Tech Circle Natick, MA 01760 P: 508-655-1340 F: 508-651-2902 Millennium ATMA setup and configuration

More information

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Combined CAN Sensor Unit Temperature, Humidity and Smoke Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical

More information

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Welcome to MultiSight TM Vision Sensor Hands-On Lab Welcome to MultiSight TM Vision Sensor Hands-On Lab About This Hands-On Lab Welcome to the MultiSight TM Vision Sensor Hands-On Lab! This session provides you with an opportunity to explore the functionality

More information

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth QUICK START FLIR Model MR59 Ball Probe Moisture Meter with Bluetooth MR59 - QUICK START - EN To obtain the detailed User Manual please visit http://support.flir.com (download tab). Please read the user

More information

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight Model: 616-143 Quick Setup Guide DC: 051916 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) Buttons Projection Focus 5.0 VAC Power Jack Battery Cover

More information

Model 3300 Technical Support and Installation Manual

Model 3300 Technical Support and Installation Manual Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration

More information

Datasheet Face Recognition [Genetec VMS]

Datasheet Face Recognition [Genetec VMS] Datasheet Face Recognition [Genetec VMS] Version 3.6 This Specification Sheet gives the details of system requirements, features and other salient points of AllGoVision Face Recognition application for

More information

Dual Spin Mop Robot Cleaner

Dual Spin Mop Robot Cleaner Dual Spin Mop Robot Cleaner Copyright 2017 EVERYBOT Inc. All rights reserved. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty... Table of Contents Preface 1 Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty... 2 Chapter 1 Radius Overview 6 1.1 About

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

Automated Infrared Thermography Complete Solutions from a Single Source

Automated Infrared Thermography Complete Solutions from a Single Source Automated Infrared Thermography Complete Solutions from a Single Source Temperature monitoring of processes Automatic surveying of thermal marks Early fire detection and site security www.infratec.eu Innovative

More information

DC200 Digital Dispenser Operating Manual

DC200 Digital Dispenser Operating Manual DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB Copyright 2016 This manual is furnished under license and may be used or copied only in accordance with the terms of such license.

More information

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Wall Hung Boiler Room Thermostat OR30 OT Thermostat 8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en 2 Contents Contents 1 Symbols and safety precautions..................................

More information

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact

More information

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual Document Number: 057-159 Author: Fady Atallah DSE94xx Configuration Suite PC Software Manual ISSUE 15 DSE94xx

More information

Dashboard for Windows V1.1.0

Dashboard for Windows V1.1.0 User manual Dashboard for Windows V1.1.0 TBS Electronics BV De Factorij 46 1689 AL Zwaag The Netherlands www.tbs-electronics.com COPYRIGHT 2009 (rev1e) - 1 - TABLE OF CONTENTS 1. INTRODUCTION......................

More information

User Manual LIGHTMEN.COM. Apollo A75050

User Manual LIGHTMEN.COM. Apollo A75050 User Manual LIGHTMEN.COM Apollo A75050 TABLE OF CONTENTS 1 Introduction... 3 1. 1 Maintenance... 4 1.2 Operating elements and connections... 5 1.3 Menu button overview... 5 1.4 Operating elements and connections

More information

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL VR40 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.........................

More information

IntelliDoX Operator Manual

IntelliDoX Operator Manual IntelliDoX Operator Manual OPERATOR MANUAL TABLE OF CONTENTS Table of Contents Table of Contents...1 About this Publication...3 Important Safety Information: Read First...4 Getting Started...5 About the

More information

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer USER MANUAL Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer MODEL IR267 Introduction Thank you for selecting the Extech Model IR267 Mini IR Thermometer. The Model IR267 IR thermometer

More information

Compact, high-power, outdoor-rated, cable-free, battery-powered LED uplight with onboard wireless DMX, infrared remote, and manual control via OLED function menu + Six-unit road-worthy custom charging

More information

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual. USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor User Manual 8690 Rev B Update: 10/24/2013 1 Table of Contents 1 Introduction.. 3 2 Host

More information

Recording Server PRELOADED

Recording Server PRELOADED Configuration English Recording Server PRELOADED Rev. 1.1.2 / 2015-12-09 Module BANK Information about copyright, trademarks, design patents 2015 Dallmeier electronic The reproduction, distribution and

More information

4-IN-1 PIN/PAD RH MOISTURE METER

4-IN-1 PIN/PAD RH MOISTURE METER 4-IN-1 PIN/PAD RH MOISTURE METER USER S MANUAL MMH800 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction................................ 3 4 Key

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

WIRELESS COLOR FORECAST STATION

WIRELESS COLOR FORECAST STATION Model: 308-1412S Manual DC: 080217 WIRELESS COLOR FORECAST STATION SENSOR TX141TH-Bv2 LED TX Sensor Battery 2 AA Buttons 3 AAA AC Power USB PORT Model: 308-1412S www.lacrossetechnology.com/support Page

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

Dry Contact Probe DCP (#30008)

Dry Contact Probe DCP (#30008) Dry Contact Probe DCP (#30008) The Networked Robotics DCP probe enables network data collection of the state of any normally open or normally closed switch. This product can sense alarm contact outputs

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

64 Max IR Thermometer

64 Max IR Thermometer 64 Max IR Thermometer Users Manual January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

More information

E529 Smart Digital Thermostat Product Guide

E529 Smart Digital Thermostat Product Guide E529 Smart Digital Thermostat Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 3 Features... Page 4 LCD Item Descriptions... Page 5

More information

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for period of one (1) Year from the date of purchase and agrees to repair or replace any defective unit without

More information

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New

More information

Users Manual. Visit us at

Users Manual. Visit us at Users Manual 568 EX Infrared Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 4326622 June 2013 2013 Fluke Corporation.

More information

Atomic Projection Alarm. Model: A Instruction Manual

Atomic Projection Alarm. Model: A Instruction Manual Atomic Projection Alarm Model: 616-146A Instruction Manual Introduction The Atomic Projection Alarm features radio-controlled time, indoor temperature, and moon phase on a simple, and easy to read display.

More information

Atomic Digital Wall Clock

Atomic Digital Wall Clock Model: BBB87269 Instruction Manual DC:102015 Atomic Digital Wall Clock Table of Contents Welcome... Get Started... Button Functions... Settings: Time, Date, etc.... Time Zone Settings and 12/24 Hour Time...

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October 2014 Serial Number 25000100 and Succeeding Serial Numbers LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October

More information

Wireless Weather Station. Table of Contents

Wireless Weather Station. Table of Contents Wireless Weather Station Model: T83646v2 Instructional Manual DC:071916 For online video support: http://bit.ly/laxtechtalk Table of Contents LCD Features... Buttons... Setup... Set Time, Date etc....

More information

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting

More information