2 orcom U Series 1U Height Power Entry Modules KEY ETURES ompact 1U (1 3/4 ) Design 115* iltered and Unfiltered SPST Switch Shrouded Quickonnect Terminals Various Mounting Styles Lower Power Dissipation Higher System Efficiency Lower ooling Demand Underwriters Laboratories Recognized, S ertified and VDE pproved* * 15 versions tested by Underwriters Laboratories to US and anadian requirements and are VDE approved at 250 V. Description The U series joins the orcom product family of Power Entry Modules, filling the need for smaller versions of our switched inlet filters and unfiltered power inlets. This series provides power entry for equipment designed for popular 1U (1 3 /4 ) height equipment racks. The filtered versions provide complete shielding, shrouded quick connect terminals and basic filtering for 1 to 15 applications, in an extremely compact size. The design is available in snapin and flanged mounting options. iltered versions are also available in a new rear mount style which provides a flush appearance with enhanced EMI shielding. The unfiltered inlet snapin versions are available in three different configurations to fit a wide vareity of panel cutouts and thicknesses and with optional preconnected terminals from the socket to the switch. The U Series features a common IE power inlet for international compatibility. Refer to the, GG, P, and M Series PEMs for applications requiring additional features. PPLITIONS Rack mounted equipment, telecom, consumer electronics, power supplies, routers, Ps, TVs, lighting, imaging equipment, settop boxes and other applications with limited panel space. STNDRD ND SPES Maximum Leakage current, each line to ground (filtered models only) V 60 Hz :.25 m 250 V 50 Hz:.40 m Hipot rating (one minute) : linetoground 1500 V, linetoline 1450 VD Operating requency : 50/60 Hz Rated Voltage : 250 V Rated currents : 1, 3, 6, 10, 15 Operating Voltage : 120/250 V Switch : Single pole single throw Terminal Pushon orce : 15 lb / 67 N (max) Electrical Schematics Line Load Tyco Electronics I orcom U Series 1U Height Power Entry Modules
3 PRODUT OERING : Part numbers iltered Versions Unfiltered Versions 1UE1 3UE1 6UE1 10UE1 15UE1 1US1 3US1 6US1 10US1 15US1 1U1 3U1 6U1 10U1 15U1 15UE1 15U15S1 15U10S1 15US1 15UE1* 15U15S1* 15U10S1* 15US1* * Preconnected terminals ase dimensions Part Numbers UE1, UE1 US1, US1 U10S1, U10S1 U15S1, U15S1 UE1 US1 U1 (max) (max) (max) D ±0.004 ± E ±0.004 ± ±0.004 ± Panel Thickness NOTE : Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specification subject to change [ ] [ ] [ ] [ ].157 [4.0] Max Minimum insertion loss in db Linetoground in 50 ohm ircuit urrent Rating requency MHz Linetoline in 50 ohm ircuit urrent Rating requency MHz
4 orcom U Series 1U Height Power Entry Modules SE DIMENSIONS cont. UE1 UE1 Preonnected Terminals Side View Rear View Line Inlet (1) : IE Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole US1 US1 Preonnected Terminals Line Inlet (1) : IE Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole Side View Rear View U10S1, U15S1 U10S1, U15S1 Preonnected Terminals Side View Rear View Line Inlet (1) : IE Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole Note : Switch output terminal configurations for any unfiltered version may vary from that shown here. Dimensions are not affected orcom U Series 1U Height Power Entry Modules I Tyco Electronics
5 SE DIMENSIONS cont. UE1 U1 Mounting holes (2) :.132 [3.35] Dia. with.260 [6.6] Dia. x 90 countersink for #4 or M3 flathead screw Line Inlet (1) : IE Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole US1 Mounting holes (2) : M3 x.5 Line Inlet (1) : IE Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole Line Inlet (1) : IE Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole Output Shroud, Inside dimension :.21 x.34 [5.2 x 8.6] Recommended panel cutout R. Max D Panel Thickness US1, US [ ] U10S [ ] U15S [ ] E U1.157 [ 4.0 ] Max Note : R=1.8 [45.72] for U, 1.0 [25.4] for all others.
6 OR MORE INORMTION Technical Support orcom Phone Internet: US: +1 (800) anada: +1 (905) Mexico & entral merica: +52(0) South merica: +55 (0) Germany: +49 (0) UK: +44 (0) rance: +33 (0) Netherlands: +31 (0) hina: +86 (0) Tyco Electronics orporation Harrisburg, P tycoelectronics.com 2010 Tyco Electronics orporation. ll Rights Reserved IS PD 01/2010 orcom, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. Other products, logos, and ompany names mentioned herein may be trademarks of their respective owners. While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this catalog, Tyco Electronics does not guarantee that it is errorfree, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. onsult Tyco Electronics for the latest dimensions and design specifications.
Introducing Corcom DB Series
Introducing orcom Series orcom Series KY TURS ompact connector for high-current applications Reliable performance in a compact assembly 60 current rating Polarized mating scheme asy customer termination
More informationQuick Reference Guide.050 Centerline Micro-MaTch Connector Series
Quick Reference Guide.050 enterline MicroMaTch onnector Series The Tyco Electronics MicroMaTch connector family, with its contact spacing of 1.27mm, offers a variety of wiretoboard and boardtoboard interconnections.
More informationIntroducing Hermaphroditic Blade and Receptacle Connector
Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and
More informationIntroducing Low Voltage DC Grid Interconnects
Introducing Low Voltage DC Grid Interconnects LVDC Grid Interconnects KEY FEATURES Power Feed Cable Assembly Power Feed Connectors are available upon special request comprising of the following: - Universal
More informationQuick Reference Guide Barrier Strips
Quick Reference Guide Barrier Strips Barrier strip style terminal blocks from Tyco Electronics are available in 3 main categories: dual-barrier, tri-barrier, and double row. Each category of barrier strip
More informationIntroducing SlimSeal SSL Connector
Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed
More informationIntroducing Solar Identification Labels
Introducing Solar Identification Labels Solar Identification Labels KEY FEATURES Recommended for use in identification of DC Disconnects and Inverters. For use on painted smooth metal and textured metal
More informationIntroducing Inverted SMT Thru Board Connector
Introducing Inverted SMT Thru Inverted SMT Thru KEY FEATURES Available in 2 through 6 positions Eliminates wire dress management issues with discreet wire leads around the surface of the LED pc board Accepts
More informationPin, Spool & Strain Insulators
Pin, Spool & Strain Insulators TE Connectivity Pin, Spool & Strain Insulators Pin, SpooL, Strain Insulators TE Energy rounds out the insulator offering to include spool, pin and strain insulators. TE s
More informationPlanarMag Product Technology
Technical Data APPLICATIONS Enterprise switches and routers Low profile Laptop, Netbook, e-readers SMB (small medium business) switches and routers Wireless router TV/DVRs/STB IP Phones and cameras Video
More informationEVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies
EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and InfiniBand Standards TECHNICAL DOCUMENTS
More informationCII FCAC-150 Series Relay
Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure
More informationEVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies
EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and Infiniband Standards Internal and External
More informationZ-PACK TinMan 85 ohm Connector Overview
Z-PACK TinMan 85 ohm High Speed Backplane Connector Z-PACK TinMan 85 ohm Connector Overview Product Facts 10+ Gbps performance 85 ohm impedance for differential pair configuration 5 pair version offers
More informationSOLARLOK Interconnection System Installation Manual
SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should
More informationAMP SUPERSEAL 1.5 SERIES Connectors
Introduction Tyco Electronics has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed
More informationENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS
ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS YOUR UNDERGROUND CONNECTION Cable accessories provide a critical backbone to today s complex underground
More informationAPPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment
RoHS Ready UMCC Ultraminiature Coax Connector & Cable Assembly Series DESCRIPTION Tyco Electronics introduces the Ultraminiature Coax Connector and Cable Assembly series products. The UMCC series is an
More informationUndercarpet Cabling Products Undercarpet Power, Voice and Data Distribution
Undercarpet Cabling Products TE Connectivity Enterprise Networks Warranty Power Distribution Product Coverage* TE Connectivity warrants that all Undercarpet cabling system products within this catalog
More informationUniversal Connectivity Platform A Modular Approach to Infrastructure Design
A Modular Approach to Infrastructure Design TE Connectivity s Universal Connectivity Platform (UCP) provides a fully modular approach to designing data centers and telecommunications rooms. This patch
More informationRoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES
KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between
More informationStandard and Customized Hand Tool Kits
Standard and Customized Hand Tool Kits Application Tooling and Equipment Portfolio Applicators Board Processing Equipment Crimp Machines and Equipment Equipment for Electrical Testing FFC-FPC Equipment
More informationRaychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO
Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO Elastomeric MV Terminations TFTI/TFTO for and Applications for Polymeric Cables up to 42 kv Push-on and Cold-shrink
More informationDEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications
DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications DEUTSCH 369 Series PCB-Mount Connectors DEUTSCH 369 Series connectors
More informationGas Discharge Tubes GTCX25-XXXM-R02 Series
Raychem Circuit Protection 5mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines
More informationAXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10
Cradle Relay Accessories and Mounting 108-98016 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet,
More informationGas Discharge Tubes. Features: Benefits: Applications:
TE Circuit Protection 5mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from
More informationDIP Switches Series. Performance Characteristics Series. Materials. Technical Documents
lcoswitch DIP switches are available in standard single pole, single throw; side actuated, single pole, single throw and multiple series versions. Contacts are made of high strength copper alloy with.000030
More informationENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS
ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS Designed and independently tested to meet all requirements of IEC 61914. Integral stainless steel clamping plates to ensure
More informationTE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv
TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) TYPE-TESTED, FIELD-PROVEN INNER CONE CONNECTORS Inner cone
More informationKILOVAC K1K High-Voltage Contactor
KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,
More informationQuick Reference Guide: Connectors for Mobile Devices
Quick Reference Guide: Connectors for Mobile evices Tyco Electronics supplies a unique expertise for today's and tomorrow's mobile equipment applications, including cellular phones, mobile media players,
More informationGas Discharge Tubes GTCX28-XXXM-R05 Series
GTCX28-XXXM-R05 Series Raychem Circuit Protection Products 8mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal
More informationReliable solutions for electrified railway systems
Reliable solutions for electrified railway systems 1 2 3 Insulation Enhancement System Insulation Enhancement System 1. Raychem MVLC: (Medium Voltage Line Cover) Provides insulation for catenary, droppers
More informationTE Connectivity's AMP NETCONNECT Cable Management
One of the major challenges facing cabling mounting holes installers and maintenance personnel is organizing distribution cables and patch cords in the telecommunications room. TE Connectivity's AMP NETCONNECT
More informationRAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS
ENERGY /// RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS ADVANCED SWITCHGEAR CONNECT TECHNOLOGY
More informationUniversal Connectivity Platform
Enabling Business Transformation through Agility Availability Efficiency UCP provides a fully modular approach to accommodate both copper and fiber into one common footprint, simplifying network architecture
More informationRAYCHEM MEDIUM VOLTAGE
ENERGY /// RAYCHEM MV OUTDOOR SURGE ARRESTERS RAYCHEM MEDIUM VOTAGE Surge Arresters for special applications Raychem MV Indoor Surge Arresters Raychem MV Surge Arresters MPA for Indoor Applications For
More informationDEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS
EUTSCH 3 SERIES PCB CONTCTS FOR 38999 SERIES III-STYE CONNECTORS QUICK REFERENCE GUIE Wide Range Mil spec, commercial, and composite shells Variety of standard and custom tail lengths available Choice
More informationGLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY
White Paper 23 May 2013 Rev A 503-32020 GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY Background Safety is paramount in the home appliance industry. Due to the possibility of human misapplication, over-current,
More informationHARTMAN Smart AC Contactors
HARTMAN Smart AC Contactors Intelligent Contactors for Critical Aerospace Applications Intelligent Power Protection Products One of the most important trends today for military and aerospace contactors
More informationQUADRAX D-SUB CONNECTORS
QUADRAX D-SUB CONNECTORS RUGGED QUADRAX DESIGN ENABLES GIGABIT ETHERNET SPEEDS WITH SUPERIOR SHIELDING PERFORMANCE FOR SIGNAL INTEGRITY QUADRAX D-SUB CONNECTORS Quadrax High-Speed Connectors WELL ESTABLISHED
More informationWILDLIFE AND ASSET PROTECTION PRODUCTS
WILDLIFE AND ASSET PROTECTION PRODUCTS Protection and Prevention Before You Need It ADVANCED PROTECTION FOR MORE RELIABLE POWER DISTRIBUTION As structural building developments and roadways increase, more
More informationLOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS
ENERGY /// LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY (LVHS JOINTS) LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS TE Connectivity (TE) offers a wide range of reliable
More informationCOMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE
COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE Robert Moore, Principal Engineer High Speed Specialist AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - COMMERCIAL PROTOCOLS AND AEROSPACE
More informationDATASHEET PolySwitch RKEF Devices
DTSHEET PolySwitch Devices For use in a wide variety of general electronic products, ranging from industrial controls to battery packs, PolySwitch devices are functionally equivalent to the PolySwitch
More informationS200 SHIELD TERMINATORS
RAYCHEM S200 SHIELD TERMINATORS FAST, EASY SHIELD TERMINATION AND GROUNDING TO 200 C RAYCHEM S200 SHIELD TERMINATORS High-Performance, High-Temperature Cable Terminators Heat-Shrinkable Sleeve for Fast,
More informationRaychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv
Energy Division Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv Our Raychem heat-shrinkable medium voltage terminations
More informationLOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE
LOW POWER AND SIGNAL APPLICATION GUIDE MORE SOLUTIONS TE Connectivity s (TE) extensive connector and sensor solutions provide the essential connectivity you need for your daily interactions at home and
More informationGLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY
GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper BACKGROUND: Safety is paramount in the home appliance industry. Due to the possibility of human mis-application, over-current, or short circuit
More informationHPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE
HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE Authors: Stefan Glaser Senior Manager Customer Engineering VWA Waldemar Stabroth Director Technical Marketing Contact:
More informationENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS
ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS TE Energy offers a wide range of reliable and cost-effective products for the electrical power industry. Our position as
More informationBowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)
Energy Division Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC) Bowthorpe EMP distribution metal oxide surge arrester DA0 series Tyco Electronics Bowthorpe EMP business
More informationFTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationSignal Connectors for Topside and Subsea Applications
Signal Connectors for Topside and Subsea Applications Withstand the Hazards of Offshore DEUTSCH signal connectors from TE Connectivity (TE) deliver rugged reliability in challenging and harsh environments
More informationLead Makers and Harness Makers
and Harness Makers and Harness Makers Application Tooling and Equipment Portfolio Applicators Crimp Machines and Equipment Electrical Test Equipment FFC-FPC Equipment Hand Tools IDC Machines Lead Makers
More informationMODEL ACCELEROMETER
MODEL 8711-01 ACCELEROMETER SPECIFICATIONS Industrial IEPE Accelerometer Low Cost, Quick Delivery -55 C to +125 C Operating Range Top Exit Connector DIMENSIONS The Model 8711-01 are internally shielded
More informationBUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals
BUDI-M-SP I N S T A L L A T I O N I N S T R U C T I O N Building distributor Introduction Suitable for FTTH applications where easily pre-connectorized splittersmodules can be build in. The box is designed
More informationApplication Specification MAG-MATE* Poke-In Tab Terminals
Application Specification MAG-MATE* 114-2050 Poke-In Tab Terminals 30 MAR 07 Rev G1 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationWire and Cable The Industry Standard for Rugged, Reliable Performance
Wire and Cable The Industry Standard for Rugged, Reliable Performance TE Connectivity A Powerful Source Pushing the Performance Envelope As one of the world s largest suppliers of passive electronic components
More informationCONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE
CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE Karl Kitts, Director of Development Engineering for High Performance Relays AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - CONTACTORS FOR AEROSPACE
More informationSeries TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General
More informationHigh Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors
DEUTSCH High Density Optical In-Line (ILC) High Performance Multichannel Fiber Optic Connectors DEUTSCH High Density Optical In-Line High Pressure/High Temperature Performance Developed from subsea and
More informationAT&T Switched Ethernet on Demand
AT&T Switched Ethernet on Demand Providing access to your services when you need them 2016 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein
More informationSeries TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description
Worldwide Contacts www.tyco-fire.com Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL,
More informationFIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement
FIST-EDSA I N S T A L L A T I O N I N S T R U C T I O N FIST-EDSA-D4 Content 1 Introduction 2 Kit content 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop
More informationINDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE
INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE RSTI-68R-HT RSTI-CC-68R-HT T-CONNECTORS FOR ROLLING STOCK -TYPE C INTERFACE Introducing
More information/Oct/2014 Rev B
Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE
More informationInsulation and Protection Enhancing the Reliability of Overhead Power Systems
Insulation and Protection Enhancing the Reliability of Overhead Power Systems TE Energy TE Energy provides solutions for substations, underground cable, overhead lines, and railway applications. These
More information/Oct/2014 Rev E
Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity
More informationEnergy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series
Energy Division Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series At the core of the Bowthorpe OCP design is our improved ZnO varistor disk, which has superior thermal and electrical characteristics
More informationCat 6 Shielded Patch cords
Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*
More informationOpen-area Smoke Imaging Detector. Engineering Specification
Open-area Smoke Imaging Detector 15273_02 October 2011 Table of Contents 1. Scope... 3 2. System Information... 3 2.1 General... 3 2.2 Approvals... 3 2.3 Codes, Standards or Regulations... 3 2.4 System
More informationVertical Mounting of Kaleidescape Components
kaleidescape Vertical Mounting of Kaleidescape Components Engineering Bulletin Most Kaleidescape components can be mounted vertically. However certain restrictions apply. 0 Intake air temperature must
More informationUniversal Retention Modules 02 MAR 10 Rev A
NOTE i Application Specification 114-26017 Universal Retention Modules 02 MAR 10 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
More informationYour Pick... One Solution
Abrasion Resistance NBCCS EMC Safety High Speed Complete Harnessing Solutions Repairability Reliability Extreme Temperatures Flexibility Your Pick... One Solution Low Outgassing Flame Retardant Fuel and
More informationTether and Umbilical Cables for Remotely Operated Vehicles
Tether and Umbilical Cables for Remotely Operated Vehicles 6000 meters down is no place for cable failure TE Connectivity (TE) helps you go deep, whether it s to the ocean floor, the bottom of a mine,
More informationSeries TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description
Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 Series TY-B 2.8, 5.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description IMPORTANT
More informationRA889A Switching Relay
Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with
More informationPT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical
Cable Actuated Sensor Absolute Linear Position to 550 inches (1400 cm) Aluminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 NEMA 6 Protection General Full Stroke
More information6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat
6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat Introduction The Airpax 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat
More informationMODEL 4000A & 4001A ACCELEROMETER
MODEL 4000A & 4001A ACCELEROMETER dimensions 4001A Connector Attachment SPECIFICATIONS Silicone MEMS Accelerometer Signal Conditioned Output Temperature Calibrated Low Cost, Lightweight The Model 4000A
More informationYOUR PORTABLE AIR PURIFIER
YOUR PORTABLE AIR PURIFIER This booklet contains important information. CAUTION: Read manual carefully for proper procedures and operation. Thank you for purchasing your new Portable Air Purifier from
More informationINSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #
INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #236477-001 Specifications... 1 Overview Silent Dial Thermostat Art. 236477-001... 1 Mounting Location... 3 DIP Switch Configuration... 3 Calibration... 5 Setting
More informationCat 6 Unshielded Patch cords
Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat
More informationPolySwitch Surface-Mount Resettable Fuses
PolySwitch Surface-Mount Resettable Fuses New surface-mount products reduce the footprint and extend the operating range of the broadest product line of surface-mount resettable fuses Raychem, inventor
More informationSpecification Status: Released
PAGE NO.: 1 OF 8 Specification Status: Released Not to be used for new designs. For new design please contact Tyco Electronics Sales BENEFITS Board space savings Help protect sensitive electronic circuits
More informationPT9420 (Extended Range)
(Extended Range) Cable Actuated Sensor Absolute Linear Position to 1700 inches (4300 cm) Stroke Range Options: 0-600 to 0-1700 inches VLS Option to Prevent Free-Release Damage IP68 NEMA 6 Protection Hazardous
More informationPT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical
Cable Actuated Sensor Absolute Linear Position Classic Stringpot Design Stroke Range Options: 0 2 to 0 100 inches Powder Painted & Anodized Aluminum Enclosure Industrial Automation & Testing Applications
More informationL8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers
Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B
More informationNECTOR S Line lighting components. Flexible solutions for your lighting designs
NECTOR S Line lighting components Flexible solutions for your lighting designs The lighting industry is always changing. It is constantly in pursuit of more energy-efficient products with longer life-spans
More informationInverted Through Board Surface
Inverted Through Board Surface Application Specification Mount Technology (SMT) 114-13245 Connector Assembly 14 DEC 09 Rev E NOTE i All numerical values are in metric units [with U.S. customary units in
More informationSeries TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description
Worldwide Contacts www.tyco-fire.com Series TY-B 2.8,.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description TYCO Series TY-B, 2.8,.6, 8.0 K-factor,
More informationCable Actuated Sensor Industrial Incremental Encoder Output
Cable Actuated Sensor Output Linear Position up to 175 inches (3 meters) 0-125, 0-175 inch Full Stroke Range Options Designed for Outdoor & IP67 environments In Stock for Quick Delivery! 175-inch model
More informationHydroSpeed plate washer for 96- and 384-well formats
HydroSpeed plate washer for 96- and 384-well formats Speed and control for optimized washing of cells, beads and ELISAs 21 CFR Part 11* 98/79/EC IVD-D* Are you washing away your cells? Loosely adherent
More informationMar11 Rev B
Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*
More informationLED RETROFIT CONVERSION KITS
Engineered Products Company s LED RetroFit Conversion Kits convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and attractive design
More informationSGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications
Cable Actuated Sensor Compact Mid-Range String Pot Absolute Position 80, 120-inch Stroke Range Options Polycarbonate Enclosure IP67 In Stock for Quick Delivery General Stroke Range Options Accuracy Repeatability
More informationES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor
Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.
More information