CII FCAC-150 Series Relay

Size: px
Start display at page:

Download "CII FCAC-150 Series Relay"

Transcription

1 Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

2 KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure All welded hermetically sealed enclosure occupies about 1 in 3 1 Form X (SPST-NO-DM) Auxiliary versions available with 1 Form C (SPDT) aux. 6, and 28 Vdc coils available Weight: 90 grams Designed and built in accordance with MIL-PRF-6106 Rated for altitude up to 300,000 ft. Available with optional terminals and mounting styles DESCRIPTION The series relay is a polarized, single-side stable design, where the flux from a permanent magnet provides the armature holding force in the deactivated state, and its flux path is switched and combined with the coil flux in the operated state. This results in appreciably increased contact pressure in both states over that of a spring return non-polar design. The series has a 1 Form C (SPDT) auxiliary contact set rated at 2 Amps available. Designed and built to perform under the most demanding environmental conditions and can withstand such changing environmental factors as temperature, altitude, shock, vibration, and salt spray. Minimum mechanical life expectancy is 50,000 cycles under resistive load. 3 available coil voltages (6, and 28 Vdc) with optional transient suppression. APPLICATIONS Used in military, aerospace, and associated ground support electrical and electronic systems. Principle areas of application include: - Aircraft - Missiles - Power Distribution - Fuel Pumps Avionics Main Power Feed Weapons Systems - Ground Support Equipment PART NUMBERING SYSTEM Typical Part Number or -A Y 3 Series and Contact Arrangement: = Relay with 1 Form X Main Contacts = Relay with 1 Form X Main Contacts and 1 Form C Auxiliary Contacts Terminals (see drawings for details): B = Solder Pin Coil Terminals, Stud Power Terminals C = Solder Hook Coil Terminals, Stud Power Terminals K = Terminal Block, Stud Power Terminals Enclosure (see drawings for details): R = Horizontal Flange Mount, Rotated U = Flush Vertical Flange Mount X = Horizontal Flange Mount Y = Raised Vertical Flange Mount Z = No Mount Coil: 1 = 6Vdc nominal 2 = Vdc nominal 3 = 28Vdc nominal 4 = 28Vdc nominal, with back EMF suppression Tyco Electronics I &

3 PERFORMANCE DATA Specifications Contact Data Contact Form : 1 Form X (SPST-NO-DM) : 1Form X (SPST-NO-DM) with 1 Form C (SPDT) Auxiliary Contacts Contact Rating in Amps (Continuous Duty) Type of Life (Min.) 5 Vac Load Cycles 28 Vdc 400Hz Resistive 50, Inductive (L/R=5ms) 20, Motor 20, None 100,000 Overload Current (Resistive) Max. Contact Drop at 10A Operate Time at Nominal Voltage Release Time Bounce Time Coil Data 200 A, 50 cycles Initial 150mV; After Life 175mV 15ms 15ms 1ms Coil Code Nominal Operating Voltage (Vdc) Maximum Operating Voltage (Vdc) Maximum Pick-Up Voltage at +5 C Maximum Pick-Up Voltage at +5 C, continuous current test (Vdc) Drop-Out Voltage at +5 C Maximum Coil Current at +25 C (ma) Back EMF Suppressed to (Vdc) N/A N/A N/A -42 Coil Resistance 18Ω 70Ω 290Ω 290Ω Electrical Data Initial Insulation Resistance (note 1) Insulation Resistance After Life or Environmental Test (note 1) 100 megohms, minimum, at 500Vdc, between each pin and case 50 megohms, minimum, at 500Vdc, between each pin and case Dielectric Strength At Sea Level Contacts to Ground and Between Contacts Coil to Ground Dielectric Strength at 80,000 ft (25,000m), All Points (note 4) Environmental Data Ambient Temperature Range, Operating Altitude Shock Resistance Vibration Resistance, Sinusoidal Mechanical Data Approximate Weight 1,250Vrms, 60 Hz. 1,000Vrms, 60 Hz. 500Vrms, 60 Hz -70 C to +5 C 300,000 feet 50 G s, ms. 20 G s, Hz. 3.2 oz. (90g) Max. NOTES 1. All wired terminals must be connected together during this test. Dielectric withstanding voltage and insulation resistance are measured between all mutually insulated wired terminals and between all these terminals and case. Tyco Electronics I &

4 FOR MORE INFORMATION Technical Support Internet: USA: +1 (800) Canada: +1 (905) Mexico: +1 (800) C. America: +52 (0) South America: +55 (0) Hong Kong: +852 (0) Japan: +81 (0) Great Britain: +44 (0) France: +33 (0) Germany: +49 (0) Italy: +39 (0) India: +91 (0) Tyco Electronics Corporation Harrisburg, PA tycoelectronics.com Copyright 2008 Tyco Electronics Corporation M GADM/FP /08 CII, TE LOGO and TYCO ELECTRONICS are trademarks.

5 TERMINALS B Solder Pin Terminals Tin/Lead Plated C Solder Hook Terminals Tin/Lead Plated.062±.002 DIA PINS 2 PLCS).062±.002 DIA PINS (5 PLCS).062±.002 DIA HOOKS 2 (PLCS).062±.002 DIA HOOKS (5 PLCS) K Terminal Shield GOLD PIN TERMINALS FOR MIL-C-39029/22B 192 SOCKET PINS Terminal View GOLD PIN TERMINALS FOR MIL-C-39029/22B 192 SOCKET PINS DC Coils Terminal Wiring DC Coils w/transient Suppression & I Tyco Electronics

6 PRODUCT OUTLINE DIMENSIONS The standard terminal types and enclosures are illustrated below with dimensions in inches ± and (millimeters ±0.25). representative drawings are shown below. "U" "Y" MAX MAX FULL R 6 PLCS.156 "X" "R" "Z" FULL R 6 PLCS MAX & I Tyco Electronics

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between

More information

KILOVAC K1K High-Voltage Contactor

KILOVAC K1K High-Voltage Contactor KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,

More information

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Hermaphroditic Blade and Receptacle Connector Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and

More information

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods

More information

Introducing SlimSeal SSL Connector

Introducing SlimSeal SSL Connector Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed

More information

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays To Be Discontinued IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays DZ RELAYS (ADZ) New New Horizontal terminal type FEATURES 1. IEC62055-31 UC3 compliant (short current

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

Introducing Low Voltage DC Grid Interconnects

Introducing Low Voltage DC Grid Interconnects Introducing Low Voltage DC Grid Interconnects LVDC Grid Interconnects KEY FEATURES Power Feed Cable Assembly Power Feed Connectors are available upon special request comprising of the following: - Universal

More information

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications : 1. Scope : 1.1 Contents 11JUL07 Rev. F DDR S.O.DIMM Socket 200 Positions This specification covers the requirements for product performance, test methods and quality assurance provisions of DDR S.O.DIMM

More information

QUADRAX D-SUB CONNECTORS

QUADRAX D-SUB CONNECTORS QUADRAX D-SUB CONNECTORS RUGGED QUADRAX DESIGN ENABLES GIGABIT ETHERNET SPEEDS WITH SUPERIOR SHIELDING PERFORMANCE FOR SIGNAL INTEGRITY QUADRAX D-SUB CONNECTORS Quadrax High-Speed Connectors WELL ESTABLISHED

More information

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10 Cradle Relay Accessories and Mounting 108-98016 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet,

More information

Jun08 Rev C

Jun08 Rev C Product Specification Connector, Card Edge,.050 Centerline 108-14034 02Jun08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Tyco Electronics.050 centerline

More information

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications DEUTSCH 369 Series PCB-Mount Connectors DEUTSCH 369 Series connectors

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Mar11 Rev C

Mar11 Rev C Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm

More information

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat 6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat Introduction The Airpax 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat

More information

Introducing Solar Identification Labels

Introducing Solar Identification Labels Introducing Solar Identification Labels Solar Identification Labels KEY FEATURES Recommended for use in identification of DC Disconnects and Inverters. For use on painted smooth metal and textured metal

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment RoHS Ready UMCC Ultraminiature Coax Connector & Cable Assembly Series DESCRIPTION Tyco Electronics introduces the Ultraminiature Coax Connector and Cable Assembly series products. The UMCC series is an

More information

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents lcoswitch DIP switches are available in standard single pole, single throw; side actuated, single pole, single throw and multiple series versions. Contacts are made of high strength copper alloy with.000030

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube MOS FET Relay in module package with SPDT (1C) This model of operated by voltage (Rated input voltage is 5 VDC.) Contribute to reduce the mounting space on the print circuit board by small package Contact

More information

5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½

5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½ 5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½ Introduction The Klixon 5BT series thermostat is a high reliability, hermetically sealed thermal switch. The single pole, double throw design

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Quick Reference Guide Barrier Strips

Quick Reference Guide Barrier Strips Quick Reference Guide Barrier Strips Barrier strip style terminal blocks from Tyco Electronics are available in 3 main categories: dual-barrier, tri-barrier, and double row. Each category of barrier strip

More information

PCB Relays Single Relays

PCB Relays Single Relays Features Small power relay Limiting continuous current 30 A Minimal weight Low noise operation Wave (THT) and reflow (THR/pin-in-paste) solderable versions For twin version refer to Double Micro Relay

More information

Schneider Electric Erie T155 Series

Schneider Electric Erie T155 Series Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan

More information

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

SWK1323AL101 H2 Keylock

SWK1323AL101 H2 Keylock Keylock 2SWK Series - Page 2 SKF Series - Page 4 SKT Series - Page 3 SWK Series - Page 5 Keylock Part Number Index 2SKF131AEL01 4 2SKF132AEL01 4 2SKF133AEL01 4 2SKF231AEL01 4 2SWK131AL101 2 2SWK132AL101

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

Table of Contents. Protective Relays

Table of Contents. Protective Relays Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses SELECTION GUIDE SELECTION GUIDE Pressure, Flow & Liquid Level Products for Aerospace & Military Uses P R E C I S I O N S E N S O R S Altitude Switches PRECISION SENSORS 50 Seemans Lane Milford, CT 06460

More information

Introducing Corcom CU Series 1U Height Power Entry Modules

Introducing Corcom CU Series 1U Height Power Entry Modules Introducing orcom U Series 1U Height Power Entry Modules orcom U Series 1U Height Power Entry Modules KEY ETURES ompact 1U (1 3/4 ) Design 115* iltered and Unfiltered SPST Switch Shrouded Quickonnect Terminals

More information

MICRO SWITCH Sealed and High Accuracy Switch Line Guide

MICRO SWITCH Sealed and High Accuracy Switch Line Guide MICRO SWITCH Sealed and High Accuracy Switch Line Guide Engineered smarter. Basically better. Honeywell Sensing and Control (S&C) offers an impressive collection of environmentally sealed limit switches

More information

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 PRODUCT DATA FEATURES Solid or split core loop-powered current transmitters Fast response time Integral DIN rail mounting flange

More information

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications: Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B

More information

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 DESCRIPTION FEATURES PRODUCT DATA Solid and Split Core Vdc Output Current Transmitters. Fast Response Time. Integral

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance 5 List of

More information

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable R Label Detection Sensor E3S-CD68/63 Detect Labels Regardless of Label Color or Luster, Bottle Color or Clarity H High-performance circuitry detects wide variety of labels on clear and colored bottles

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Column-shaped Sensor Capable of Sensing Range Setting Ensures the stable detection of a variety of objects regardless of the color, transparency, or material (metallic

More information

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE ANSUL INSTALLATION OPERATION AND MAINTENANCE MANUAL ANSUL AUTOMAN II-C RELEASING DEVICE 001799 This manual is intended for use with the ANSUL AUTOMAN II-C Releasing Device. Those who install, inspect,

More information

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost SPECIFICATIONS PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost The MS1471 is a piezoresistive silicon pressure sensor packaged in a surface mount configuration. It is intended

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

DP86 Constant Voltage with Fitting

DP86 Constant Voltage with Fitting SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers: CLM-Series - Solid State Power Controller - Overview CLM-SERIES SOLID STATE POWER CONTROLLER The CLM-Series is a 12 output, solid state power controller. It provides fast switching with low loss solid

More information

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA EL7611A/EL7612A Ultrasonic Occupancy Sensors and PRODUCT DATA Proven 30% to 60% utility cost savings because lights are on only when needed. Low initial cost allows fast payback. Models available for 1000

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001 POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES PRODUCT DATA FEATURES Solid and Split Core, Fixed Current go/no go switches. Very low operating trip points. LED

More information

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description Magnetic-Inductive Flow Velocity Sensor PIT Device Description Table of contents 1 IDENTIFICATION...3 1.1 Manufacturer/supplier...3 1.2 Product type...3 1.3 Product name...3 1.4 Issue date...3 1.5 Version

More information

DTA. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in

More information

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. 7PG17 XR105, XR106 and XR107, XR205 and XR206 Interposing

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

Plug-in Base, Long Range Sensor E3B2

Plug-in Base, Long Range Sensor E3B2 Plug-in Base, Long Range Sensor Plug-in Terminal for Easy Maintenance and Installation Universal AC/DC supply voltage Replace sensing head without rewiring Detect shiny objects with polarized retroreflective

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Standard SPECIFICATIONS FEATURES APPLICATIONS

Standard SPECIFICATIONS FEATURES APPLICATIONS SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer FEATURES Heavy Industrial CE Approval (amplified only) As Low As ±0.1% Pressure Non Linearity Rugged Construction: Can Withstand 50g Shock/20g Vibration Up to -40 C to +125 C Operating Temperature Range

More information

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages

More information

MARC70 Installation Manual

MARC70 Installation Manual MARC70 Installation Manual SA 3/L/NVG SA 15 SA 24 SR 34 SR 54 SR 64 SR 263 SR 342 SR 623 SRU 1 SRU 5 SRU 10 3700 Osuna Rd. NE, Suite 711 Albuquerque, NM 87109 505.341.2930 www.sandia.aero 305147-00 This

More information

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer SPECIFICATIONS 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections

More information

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE Karl Kitts, Director of Development Engineering for High Performance Relays AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - CONTACTORS FOR AEROSPACE

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers: CLM-Series - Solid State Power Controller - Overview CLM-SERIES SOLID STATE POWER CONTROLLER The CLM-Series is a 12 output, solid state power controller. It provides fast switching with low loss solid

More information

Mors Smitt Industrial Technology. Substation Protection & Control. High Performance Electromechanical Relays. RMS Mors Smitt A Wabtec company

Mors Smitt Industrial Technology. Substation Protection & Control. High Performance Electromechanical Relays. RMS Mors Smitt A Wabtec company Mors Smitt Industrial Technology Substation Protection & Control High Performance Electromechanical Relays Power generation and distribution operators across the world rely on our relays 2 www.morssmitt.com

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

HARTMAN Smart AC Contactors

HARTMAN Smart AC Contactors HARTMAN Smart AC Contactors Intelligent Contactors for Critical Aerospace Applications Intelligent Power Protection Products One of the most important trends today for military and aerospace contactors

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS) AD0412HB-C71GP DC FAN (RoHS) P.S. REV. (P) A Y D A T A - S H E E T Engineering Printed On: 11/07/18 BRUSHLESS AXIAL COOLING FANS Customer Ref: (RoHS) Adda Model No AD0412HB-C71GP P.S: (P) Samples attached

More information

.025 Connector Series

.025 Connector Series Highlights Automotive connector series: 30 % smaller size than the existing.040 III connectors and designed to resist fretting corrosion. Features.025 Connectors with a full range of product lines..025

More information

Proximity Sensors Line Guide

Proximity Sensors Line Guide Line Guide Uncommon sense. Honeywell Sensing and Control (S&C) offers environmentally sealed proximity sensors in a variety of technologies including Eddy Current Killed Oscillator (ECKO) and Hall-effect.

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Cylindrical Ultrasonic Proximity Sensor with Separate Amplifier Unit Stable operation for a variety of objects regardless of color, transparency, or material (metallic

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID Product ID Type # Product # Drawing # 378Z-05380 DSS 1210.00 STV (5m) 113807 374Z-04996 DSS 1210.02 PHV 112705 374Z-05052 DSS 1210.02 SHV (2m) 112865 378Z-05864 DSS 1210.12 AHV 115675 378Z-05910 DSS 1210.13

More information

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits 01 VAMP 120 & 121 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Bulletin 1608N MiniDySC Dynamic Sag Corrector User Manual Bulletin 1608N MiniDySC Dynamic Sag Corrector Single Phase Voltage Sag Correction 2...6 Amps (250...750 VA) Important User Information Solid-state equipment has operational characteristics

More information

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information