Remote Booster Power Supplies

Size: px
Start display at page:

Download "Remote Booster Power Supplies"

Transcription

1 Remote Booster Power Supplies XLS-BPS6, XLS-BPS60, XLS-BPS6C, XLS-BPS0, XLS-BPS00, XLS-BPS0C FEATURES SPECIFICATION DATA Extends power available to Notification Appliance Circuits (NACs). Available in 0A and 6.5A versions. Includes four independent A NACs two configurable as auxiliary outputs. Configurable signal rates. Field selectable input-to-output correlation. Two inputs allow activation by Signature Series modules or existing NACs. NACs can be configured for four Class B or two Class A circuits. 0 Vac and 0 Vac versions. On-board status LEDs for easy recognition of wiring faults. APPLICATION The Remote Booster Power Supply is a self-contained 4 Vdc power supply designed to augment fire alarm audible and visual power requirements. The booster contains all of the necessary circuits to monitor and charge batteries, control and supervise four Class B or two Class A Notification Appliance Circuits (NAC) and monitor two controlling inputs from external sources. Simple switch selection provides a wide variety of operational configurations. Each remote booster power supply is supplied with its own enclosure providing ample space for additional interface modules and a battery compartment. The Remote Booster Power Supply is available in 6.5A or 0A versions at 4 Vdc. The Remote Booster Power Supply provides additional power for audible and visual devices when constrained by system capacity or site application. Fault conditions detected by the XLS-BPS open the NAC of the main panel. This initiates a trouble condition and eliminates the need to wire a separate trouble contact back to the control panel. During alarm conditions, detected faults are overridden. The XLS-BPS default output configuration is continuous 4 Vdc on all NACs. This output is typically used to drive visual devices. XLS-BPS notification appliance circuits easily configure to any one of the three signaling rates: 0 strokes per minute (spm), -- temporal, or continuous. This makes the XLS-BPS ideal for applications requiring signaling rates not available from the main panel. It also allows independent setup of a NAC without interfering with the main panel and its initiating circuits. In addition to the three generated signal rates, the XLS-BPS can also be configured to follow the signal rate of the main panel NAC. This allows seamless expansion of existing NACs. The XLS-BPS includes seven on-board LED indications: one for each resident NAC, one for battery supervision, one for ground fault and one for ac power. The trouble contact has a 6-second delay when an ac power failure or brownout condition is detected. This reduces trouble reports during short ac brownouts. Configuration options include: ac power fail delay (6-seconds or 6 hours), sensing input to NAC output correlations and auxiliary outputs. NAC and 4 are configurable as auxiliary outputs. Auxiliary outputs can be continuously on, or turn off after 0-seconds without ac power. Jumpers configure the XLS-BPS for Class A or B wiring. U.S. Registered Trademark Copyright 00 Honeywell All Rights Reserved

2 REMOTE SUPPLIES SPECIFICATIONS (0) Models: The Honeywell XLS-BPS Series Booster Power Supplies extend NACs as a stand-alone booster power supply. See the Ordering Information section for available models. The power supply requires standby batteries (not provided) for 4 or 60 hours of standby followed by 5 or 0 minutes of alarm and can support up to 0A hour batteries. The booster supply also requires four independent supervised NACs. NACs can be configured to follow the NAC input from the main panel or activate from Intelligent Signature Series modules. The booster NACs may be configured for independent operation at a continuous rate, at 0 SPM, or at -- temporal. Booster fault conditions will not impede alarm activation of NAC host circuits. -/ (89) -/8 (86) 7 (4) TOP VIEW (0) 7 (78) FRONT VIEW ALL KNOCKS FOR /4 (9) CONDUIT -/ (89) Electrical Ratings: AC Line Voltage: 6.5A Booster: 0 Vac or 0 to 40 Vac, 50/60 Hz, 50W. 0A Booster: 0 Vac or 0 to 40 Vac, 50/60 Hz, 75W. Notification Appliance Power: 6.5A Booster: A maximum per circuit at 4 Vdc nominal, 6.5A maximum total for all NACs and auxiliary circuits. 0A Booster: A maximum per circuit at 4 Vdc nominal, 0A maximum total for all NACs and auxiliary circuits. Auxiliary Outputs: Two configurable outputs replace NACs and/or 4, NAC and/or 4 are configurable as auxiliary outputs. Input Current (from an existing NAC): ma at Vdc, 6 ma at 4 Vdc. Temperature Ratings: F to 0 F (0 C to 49 C). Humidity Ratings: 0 to 9% RH, non-condensing. Wiring: Gauge: 8 to AWG (0.8 to. sq mm). NAC Style: Class A or B. WIRG Fig.. XLS-BPS dimensions in in. (mm). M45 Single boosters can be placed anywhere on a notification appliance circuit. Because existing NAC end-of-line resistors are not required to be installed at booster terminals, multiple boosters can be driven from a single NAC circuit without the need for special configurations. See Fig. through 6 for typical wiring applications. IMPORTANT Do not attempt to wire the booster from these diagrams. For installation instructions, refer to form no. P/N 70946, Booster Power Supply Installation Manaual and form no for a list of compatible devices. Output Signal Rates: Continuous, 0 SPM, -- temporal, or follow NAC from installed panel. Mounting: Signature module accommodates three two-gang modules. TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR Battery Size, Maximum: 0Ah ( of V, 0A). Approvals: UL, ULC, FM, CSFM. Dimensions: See Fig.. FIRE ALARM CONTROL PANEL SENSOR PUT SENSOR PUT NAC PUT NO. M46 Fig.. Multiple Signature modules branching single NAC

3 REMOTE SUPPLIES TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR FIRE ALARM CONTROL PANEL SENSOR PUT NAC PUT NO. TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR SENSOR PUT NAC PUT NO. TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR SENSOR PUT NAC PUT NO. M47 Fig.. Multiple boosters cascaded from a single NAC. TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR SENSOR PUT NAC PUT NO. TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR ALL FIVE PUTS ACTIVATE WHEN PUT NAC NO. ACTIVATES (BASED ON PROGRAMMG) FIRE ALARM CONTROL PANEL SENSOR PUT SENSOR PUT NAC PUT NO. SENSOR PUT TO NEXT SIGNALG DEVICE, BOOSTER, OR RESISTOR NAC PUT NO. ALL FIVE PUTS ACTIVATE WHEN PUT NAC NO. ACTIVATES (BASED ON PROGRAMMG) M48 Fig. 4. Multiple notification appliance circuits branched from single control panel

4 REMOTE SUPPLIES Signature modules are used to activate the booster. The wiring configuration in Fig. 5 eliminates the necessity of using a NAC circuit as an AUX or running a separate 4V source. Signature modules can also be used to divide the A booster output circuits into smaller current loads. MA BOARD NAC NAC 5K NAC 5K NAC4 /AUX P P L N G P4 SENSE SENSE TROUBLE BATTERY - NO NC P 47K 0 9 CCS USED FOR ANOTHER CLASS B. 5 GOG DATA TO NEXT DEVICE. G DATA FROM PREVIOUS DEVICE OR SIGNATURE CONTROLLER. CCS DRAWS 6 ma OF CURRENT ALARM. CCS WIRG MUST BE WITH FT OF THE BOOSTER WIRG. MOUNT CONDUIT OR WITH THE BOOSTER ENCLOSURE. 4 BATTERIES. 5 UL LISTED -LE FUSE HOLDER, PART NO WITH MAXIMUM 4A FUSE. NOTE: ANY BOOSTER TROUBLE WILL CAUSE THE CCS SUPERVISION TO REPORT A TROUBLE TO THE MA FIRE PANEL. M58A Fig. 5. Signature module used to activate booster

5 REMOTE SUPPLIES See Fig. 6 to configure the outputs where zoning is required. MA BOARD NAC NAC 5K NAC 5K NAC4 /AUX P P L N G P4 SENSE SENSE TROUBLE BATTERY - NO NC P 47K 47K 0 9 CC CC RISER TO 4 VDC RISER TO NEXT DEVICE OR RISER SUPERVISORY DEVICE USED FOR ANOTHER CLASS B. S MUST BE WIRED AND PROGRAMMED ON THE SIGNATURE CONTROLLER FOR PROPER OPERATION. CC WIRG MUST BE WITH FT OF THE BOOSTER WIRG. MOUNT CONDUIT OR WITH THE BOOSTER ENCLOSURE. NOTES: - BOOSTER RECOGNIZES TROUBLE AND ALERTS CC SUPERVISION TO REPORT TROUBLE TO THE MA FIRE PANEL. - MAXIMUM OF TEN SIGA CCI/UM S FOR BOOSTER NAC. M59 Fig. 6. Multiple Signature modules as booster inputs

6 REMOTE SUPPLIES Multiple Signature modules can be used as booster inputs. The wiring diagram in Fig. 7 can be used to configure the outputs when zoning is required. MA BOARD NAC NAC 5K NAC P NAC4 P SENSE SENSE NO TROUBLE NC BATTERY P L N G P4 - FROM EXISTG FIRE ALARM PANEL NOTIFICATION CIRCUIT OR CC. TO OR NEXT DEVICE. 0 9 CC A TOTAL 47K USED FOR ADDITIONAL CLASS B S. NOTE: MAXIMUM OF TEN SIGA CC OR SIGA UM S PER BOOSTER NAC. GOG DATA TO NEXT DEVICE. G DATA FROM PREVIOUS DEVICE OR SIGNATURE CONTROLLER. 47K.5A TOTAL 0 9 CC K GOG DATA TO NEXT DEVICE. G DATA FROM PREVIOUS DEVICE OR SIGNATURE CONTROLLER. M40 Fig. 7. Multiple Signature modules branching a single NAC

7 REMOTE SUPPLIES ORDERG FORMATION Model Number Description Parts XLS-BPS6 6.5A Booster Power Supply (UL Listed Version). (5.9) XLS-BPS60 6.5A Booster Power Supply (0V). XLS-BPS6C 6.5A Booster Power Supply (ULC Listed Version). XLS-BPS0 0A Booster Power Supply (UL Listed Version). XLS-BPS00 0A Booster Power Supply (0V). XLS-BPS0C 0A Booster Power Supply (ULC Listed Version). Accessories V6A5 6.5 Ah Batter, two required..4 (.6) V0A 0 Ah Battery, two required. 9.5 (4.) UL Listed Fuse Holder with maximum 4A Fuse. Shipping Weight lb (kg)

8 Automation and Control Solutions Honeywell International Honeywell Europe S.A. Honeywell Latin American Honeywell Honeywell Limited-Honeywell Limitée Control Products Avenue du Bourget Region 985 Douglas Drive North 5 Dynamic Drive Honeywell Building 40 Brussels 480 Sawgrass Corporate Parkway Golden Valley, MN 554 Scarborough, Ontario 7 Changi Business Park Central Belgium Suite 00 MV 4Z9 Singapore Sunrise FL J.S. Rev. 8-0 Printed in U.S.A. on recycled paper containing at least 0% post-consumer paper fibers.

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7823/RM7823 Relay Module 7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier

More information

CR7075 Two-Stage Lighting Controller

CR7075 Two-Stage Lighting Controller CR707 Two-Stage Lighting Controller FEATURES PRODUCT DATA Light intensity threshold levels field-adjustable by user. Independent Time of Day (TOD) override inputs. Optimum start/stop of lighting loads.

More information

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7885A/RM7885A Relay Module 7800 SERIES EC7885A/RM7885A Relay Module SPECIFICATION DATA 1. Torch-ignited main burner using the S445A Start-Stop Station, or any conventional knee or foot operated start-stop station. 2. Torch-ignited

More information

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES RM7840E,G,L,M Relay Module 7800 SERIES RM7840E,G,L,M Relay Module APPLICATION SPECIFICATION DATA The Honeywell RM7840 is a microprocessor based integrated burner control for automatically fired gas, oil or combination fuel single

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

TrueAlert Addressable Notification

TrueAlert Addressable Notification UL, ULC Approved* TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender Features IDNAC Repeaters provide enhanced power delivery to TrueAlert/ TrueAlert ES addressable notification

More information

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA EL7611A/EL7612A Ultrasonic Occupancy Sensors and PRODUCT DATA Proven 30% to 60% utility cost savings because lights are on only when needed. Low initial cost allows fast payback. Models available for 1000

More information

Electronic Thermostat

Electronic Thermostat Set FAN Auto On Room SYSTEM Cool Off Heat M18535 Electronic Thermostat OWNER S GUIDE Em Ht Aux Ht Set Room FAN Auto On SYSTEM Cool Off Heat Em.Ht. M18539 1 69-1490 69-1490 Congratulations on the purchase

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

T8011R Programmable Heat Pump Thermostat

T8011R Programmable Heat Pump Thermostat T8011R Programmable Heat Pump Thermostat FEATURES PRODUCT DATA APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual

More information

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

MR-2602 Two Zone Fire Alarm Control Panel

MR-2602 Two Zone Fire Alarm Control Panel MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with

More information

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat 1.0 GENERAL 1.1 Overview GUIDE SPECIFICATION The contractor shall furnish, install, and place in operating condition an HVAC

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation

More information

T8411R Electronic Heat Pump Thermostat

T8411R Electronic Heat Pump Thermostat T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 052313 Agency Listings: UL Listed for Control Units for

More information

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction Riser and Point-to-Point Drawings for Standard Access Control Applications Using Maintained Latch Retraction Control or Momentary

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

F25F Media Air Cleaner

F25F Media Air Cleaner F25F Media Air Cleaner FEATURES PRODUCT DATA High efficiency media filter captures particles as small as 1.0 micron. Efficiency and arrestance ratings based on the American Society of Heating, Refrigerating

More information

H1008A,D Automatic Humidity Controls

H1008A,D Automatic Humidity Controls H00A,D Automatic Humidity Controls FEATURES PRODUCT DATA The H00A,D provides automatic control for by-pass flow-through, powered flow-through, steam and drum humidifiers in central heating systems. The

More information

Remote Booster Power Supply Technical Reference Manual

Remote Booster Power Supply Technical Reference Manual E Security Fire & Life Safety Remote Booster Power Supply Technical Reference Manual P/N 3100485 RE 3.0 ISS 06JUL07 Copyright Copyright 2007 E Security, Inc. ll rights reserved. This document may not be

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

IS Series Pressure Sensing Switches

IS Series Pressure Sensing Switches IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential

More information

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS 63-2652 FEATURES Typically used in buildings (including: restaurants, shopping malls, office buildings and banks) under 55,000 square feet.

More information

Access Power Controllers with Power Supplies

Access Power Controllers with Power Supplies Access Power Controllers with Power Supplies Installation Guide Models Include: Maximal11FD - Power Supply 1: 12VDC @ 3.3A or 24VDC @ 3.6A. - Power Supply 2: 12VDC @ 3.3A or 24VDC @ 3.6A. - Sixteen (16)

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) SECTIONS General Description.... 1 Warnings.... 2 Technical

More information

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules R784, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules PRODUCT DATA The R7851C Dynamic Self- Optical lame Amplifier is a solid state plug-in amplifier that responds to ultraviolet

More information

FMR Installation Instructions. Addressable Fire System Controller

FMR Installation Instructions. Addressable Fire System Controller FMR-7033 EN Installation Instructions Addressable Fire System Controller EN 2 FMR-7033 Installation Instructions Contents Contents Contents...2 1.0 Introduction...3 2.0 Description...3 3.0 Device Mounting...3

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control MANUAL RELEASE - IDNET IN + +IDNET IN - RED NA C+ N A C - COIL SUPERVISION MODULE ( 2 AMP) 28-946 INSTALLATION INSTRUCTIONS 574-437 REV YEL MA IN T A IN /4 "S E P A R A T IO N BETW EEN POW ER LIMITED (

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0 CFP-105 Fire Alarm Control Panel Installation Manual Version 1.0 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification

More information

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has

More information

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

D7053. Installation Instructions Multiplex Input/Output Module

D7053. Installation Instructions Multiplex Input/Output Module D EN Installation Instructions Multiplex Input/Output Module D Installation Instructions Notices Notices These instructions cover the installation of the D Multiplex Input/Output Module in a fire system

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information