1 Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE What You Measure, We Manage

2 ABOUT US ABOUT US DRM Technic is a global manufacturer and supplier of gas analysis solutions and gas detection products. We provide expert solutions to our clients which range from small independents to global manufacturers. We offer unrivalled customer service which is supported by our unique guarantee, and implemented by our valued, motivated and skilled team. We believe in quality, honesty and reliability. It is our vision to be our customers preferred full service provider (including installation, spares and service) and to create and maintain strong, valued and trusted relationships with all of our customers. PURCHASE OPTIONS We accept cheques, credit/debit cards and electronic bank payments. We also offer monthly credit accounts, subject to status. We are an established exporter and are pleased to offer a complete export service for our large product range. We can export our products worldwide. CONTACT DETAILS Address: DRM Technic Ltd, 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB, UK Telephone: +44 (0) sales@drmtechnic.com 2

3 Heated Sample Lines Contents CONTENTS Probe Finder 4 GAS GAS GAS GAS ATEX 8 GAS ATEX 2 9 GAS GAS ATEX 11 GAS ATEX 2 12 GAS GAS ATEX 14 GAS ATEX 2 15 GAS GAS ATEX 17 GAS ATEX 2 18 RSS 24 / RSS 230 Blowback Controllers 19 GAS 222 Accessories 20 3

4 PROBE FINDER Non-Hazardous Areas Both Hazardous Areas Dust Concen. Filter Type Heated; Self-Regulated Heated; Regulated Unheated Heated Zone 1 Heated Zone 2 Max Process Temp. Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 200 o C GAS GAS GAS GAS ATEX GAS ATEX 2 Up to 2 g/m 3 downstream filter GAS GAS GAS GAS ATEX GAS ATEX o C - - Steam Heated GAS DH - - > 2 g/m 3 in-situ filter - GAS GAS GAS ATEX GAS ATEX O C > 2 g/m 3 in-situ and downstream filter - GAS GAS ATEX GAS ATEX o C > 2 g/m 3 easy remove in-situ filter - GAS GAS U GAS ATEX GAS ATEX o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 120 o C > 2 g/m 3 in-situ filter - - ECO o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 600 o C > 2 g/m 3 in-situ filter - - APO o C 4

5 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated for applications with specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated with Downstream Filter Easy Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature +180 C (Self-regulating) Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 5

6 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated to application specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Self-Regulating Up to 180 C with Low Temperature Alarm For Dust Concentrations of Up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature Self-regulating; +180 C Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 6

7 DRM Technic -- Sample Probes -- Sample Probes GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temp. Alarm & Display Easy Filter Replacement Effective Insulation and Protection Shield For Dust Concentrations up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class - IP54 Ambient Temp C 7

8 GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Downstream Filter, Weather Protection Shield and Junction Box Easy Filter Element Replacement C-US and CSA Approval For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS ATEX SS Graphite, SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60 Hz Type C: External Circuit Breaker 2A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature -20 to 50 C Temperature Self-regulating; approx. 80 C Ex-marking of the basic unit 1 GD / 2 GD T4 T130 C 8

9 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Downstream Filter and Weather Protection Shield Effective Insulation and Protection Shield For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Specified for Use in Hazardous Areas Product No. GAS ATEX SS Graphite, SS + filter elements Heater V, 50/60 Hz Temperature Self-regulating; C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3 3G c IIC T3 II 3G EEx na L IIC T4 3G c IIC T4 9

10 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Shut Off Valve, alongside an In-Situ and/or Downstream Filter Tool-less Downstream Filter Element Replacement Effective Insulation and Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS; ball valve: SS PTFE, Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 10

11 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ / Downstream Filter and Weather Protection Shield Tool-less Filter Replacement Self-Regulating at up to 90 C For Dust Concentrations of up to 2 g/m³ with In-Situ Filter and 10 g/m³ with In-situ and Downstream Filters ATEX Certified Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS ATEX SS; ball valve: SS PTFE, Graphite, SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C External Circuit Breaker Type C: 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ and/or downstream Ex-marking of the Basic Unit. 1 GD / 2 GD T4 T130 C 11

12 GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, plus an In-Situ and/or Downstream Filter Easy Tool-less Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating at up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ ATEX Certification Product No. GAS ATEX SS ball valve: SS Graphite, SS + filter elements Temperature Self-regulating; 130 C (T3) / 70 C (T4) Low Temperature Alarm Contact is open at operating temp.; closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Pressure Shut-Off Valve 6 to 8 bar Suitable for II 3G EEx na L IIC T3; 3G c II C T3; II 3G EEx na L IIC T4; 3G c IIC T4 12

13 DRM Technic -- Sample Probes -- Sample Probes GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS; ball valve: SS PTFE, Graphite, SS Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 13

14 GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, Internal Filter and Weather Protection Shield Self-Regulating at Up to 90 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX ; ball valve: PTFE, Graphite, SS Max. Flow Rate 1000 l/h Max. Inlet Tempertature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C Type C: External Circuit Breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 14

15 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Self-Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX SS; ball valve: SS PTFE, Graphite and SS Self-regulating; Temperature C (T3) / + 70 C (T4) Contact is open at operating temperature; closes at < 95 C (T3) Low Temperature Alarm resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3; 3G c IIC T3; Suitable for II 3G EEx na L IIC T4 ; 3G c IIC T4 15

16 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Tool-less Filter Replacement Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Range 50 to 200 C Adjustable; K from Alarm set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 16

17 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ Filter and Weather Protection Shield Tool-less Element Replacement Self-Regulating at Up to 80 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX PTFE, Graphite, SS + filter elements Max. Flow Rate 1000 l/h Max. Inlet Temperature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 80 C Type C: External circuit breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 17

18 GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Self- Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX SS PTFE, Graphite, SS + filter elements Voltage V, 50/60 Hz Temperature Self-regulating; C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Suitable for II 3G EEx na L IIC T3; 3G c IIC T3; II 3G EEx na L IIC T4; 3G c IIC T4 18

19 DRM Technic -- Sample Probes -- Sample Probes RSS 24 / RSS 230 Blowback Controllers RSS 24 / RSS 230 BLOWBACK CONTROLLERS The Blowback Controllers RSS 24 and RSS 230 are meant for controlling the cleaning cycles of a probe filter. They are designed for use with probe types GAS , GAS and ECO-01, but may also be used to control other external valves. Programmable Blowback / Sample Time Status Control Wall Mounted Product No. RSS 24 RSS 230 Power Supply 24 V DC ± 10% V AC 50/60 Hz Fuse 5 A (slow) 1 A (slow) Relais Output Max. 10 A / 24 V DC / 75 W Max. 10 A / 230 V AC / 690 VA Ambient Temperature 0-55 o C 0-55 o C Blowback Time 0-60 s 0-60 s Sample Time 1 min - 99:59 h 1 min - 99:59 h Protection Class IP 65 IP 65 Weight Approx. 3 kg Approx. 3 kg Dimensions (H x W x D mm) 300 x 300 x x 300 x 180 TIME FLOW DIAGRAM For more information, please feel free to contact our sales department 19

20 GAS 222 Sample Probe Accessories GAS 222 SAMPLE GAS PROBE ACCESSORIES We have a large range of Accessories for GAS 222 Sample Gas probes. See below for our Blowback Accessories, including Capacitive Vessels, Pneumatic Actuators, 3/2-way Solenoid Valves and Blowback Controllers. Overleaf are the details of our Sample Tubes, In-Situ Filters, Protection Sheilds and Extensions, all available in various materials, in various dimensions, and as heated and non-heated versions. 20

21 DRM Technic -- Sample Probes -- Accessories GAS 222 Sample Probe Accessories 21

22 DRM Technic Ltd 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB United Kingdom Tel: +44 (0) sales@drmtechnic.com

SITRANS F M MAG 3100 P:

SITRANS F M MAG 3100 P: Dedicated for the chemical industry SITRANS F M MAG 3100 P: The electromagnetic flowmeter solution with devoted features. Process Instrumentation usa.siemens.com/mag The best choice for the chemical industry

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

Gas cooler series TC-Standard+ X2

Gas cooler series TC-Standard+ X2 Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

PROFIBUS-PA Display RID 261 PROFIBUS-PA

PROFIBUS-PA Display RID 261 PROFIBUS-PA Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com Danfoss controls tailored for use in hazardous

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration Level Measurement Siemens AG 2012 Overview Configuration Installation Standpipes 0 (2) 20 (0.79) max. is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces,

More information

SET-2000 Hi Level/Oil

SET-2000 Hi Level/Oil Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47

More information

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS ABB The Company We are an established world force in the design and

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger X-am 3000 ST-2881-2003 Dräger X-am 3000 is an innovative 2 to 4 gas warning-device. This small and lightweight instrument

More information

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger

More information

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such

More information

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview. Siemens AG 00 Overview Configuration Installation Standpipes 0 () 0 (0.79) max. Wall Restriction is a compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces,

More information

Hazardous Area Zirconia Oxygen Systems

Hazardous Area Zirconia Oxygen Systems Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions QUANTURA DISHWASH DOSING SYSTEMS revolutionary dispensing solutions QUANTURA BRIGHTWELL DISPENSERS NEW RANGE OF DISHWASH DOSING SYSTEMS Reliable and efficient chemical dosing systems ensure that commercial

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0) Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X Installation Instructions P/N MMI-20010174, Rev. A June 2007 ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X For ATEX-approved sensor installations

More information

Sample Gas Probes Series GAS 222

Sample Gas Probes Series GAS 222 Sample Gas Probes Series GAS 222 A comprehensive range of basis units heated (selfregulating, regulated, steam) unheated probes for hazardous areas Zone 1 or 2 in-situ or downstream filters high dust concentration

More information

Building Services Brochure

Building Services Brochure Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving

More information

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high

More information

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC Microview Compact ATEX Hygrometer II 1G EEx ia IIC T4 T a = -20ºC to +60ºC MCM s ATEX On-Line Hygrometer Redefines Hazardous Area Applications! Continuous on-line analysis or incorporate the Microview

More information

Condensate drains WA/PWEA

Condensate drains WA/PWEA Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet CMB_PDS_340AC_AutoCal Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Can be easily

More information

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments - API Marine Sensors Presentation Mission critical applications in harsh environment - API - Acoustic Precise Instruments - API Marine API Marine - Acoustic Precise Instruments Development, design and production

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Rotameter series 250 metal tube variable area flowmeter

Rotameter series 250 metal tube variable area flowmeter Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and

More information

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au

More information

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT EXPLOSION PROTECTION Experts in Equipment for Explosive Atmospheres Ex SPECIALISTS TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT LIGHTING Portable, Temporary & Fittings Hazardous area lighting and

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT API MARINE Acoustic Precise Instruments Development, design & production of advanced tank sensors and automation systems for marine

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Illumination unit For sight glass level indicator Model LGI

Illumination unit For sight glass level indicator Model LGI Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

AUDIBLE SIGNALIZATION

AUDIBLE SIGNALIZATION 01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency

More information

MICROSENSE FLOW SWITCH

MICROSENSE FLOW SWITCH MICROWAVE FLOW SWITCH Elec Iss. 03 MICROSENSE FLOW SWITCH FOR SOLIDS, GRANULES AND POWDERS MICROSENSE - PRINCIPLE OF OPERATION The Microsense microwave switch provides an effective way of detecting the

More information

DESCRIPTION. 42 mm. 125 mm

DESCRIPTION. 42 mm. 125 mm RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller

More information

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001 POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

Dual-point heat-tracing control system

Dual-point heat-tracing control system Dual-point heat-tracing control system 920*E4FWL*SIS302*SS3102 shown Product overview The Raychem 920 is a compact, full-featured, microprocessor-based, dual-point heat-tracing control system. The 920

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date: Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe

More information

Zircomat Oxygen Analyzers

Zircomat Oxygen Analyzers Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

Instrumentation Products and Applications

Instrumentation Products and Applications 1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems

More information

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control Pac Ex 2 Elegant and smart Explosive hazards and lack or surplus of oxygen under control Portable instruments protecting people against explosive hazards and lack or surplus of oxygen are used in a large

More information

Instrumentation for Nuclear Applications

Instrumentation for Nuclear Applications Instrumentation for Nuclear Applications Nuclear Instrumentation Overview Delta Controls has been designing and manufacturing instrumentation for the power and process industries for over 65 years and

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5

More information

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators POWERVAP - EX GENSER Scientific Instruments GERMANY NOW AVAILABLE High performance PTFE-sealings for all glass connectors Loss of pressure of the complete system < 2 hpa/h (system empty) Also available

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Continuous level measurement Ultrasonic transmitters

Continuous level measurement Ultrasonic transmitters Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.

More information

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 1000 COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC Thermocouple trip amplifiers KHA6GT*Ex1 23 V AC 1channel Input EEx ia IIC Cold junction compensation 2 switching points operate on 2 output relays High/low alarm can be selected for each switching point

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Gas cooler series RC 1.1

Gas cooler series RC 1.1 Gas Analysis Gas cooler series In the chemical industry, petrochemistry or biochemistry, reliable process control relies on prompt and exact determination of the operating parameters. Here, gas analysis

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks

More information

INSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE

INSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE INSTRUCTION MANUAL Change Over Unit ECO for ETC 24R MOBATIME BE-800356.00 Certification of the Producer STANDARDS The device has been developed and produced in accordance with the EU Standards 89 / 336

More information

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous

More information

Portable sample gas conditioning PCS.smart+

Portable sample gas conditioning PCS.smart+ Gas Analysis Portable sample gas conditioning PCS.smart+ Carrying out accurate and reliable gas analyses in changing locations requires a small, compact gas conditioning system. We developed a complete

More information

Products Overview. Your trusted partner in process instrumentation

Products Overview. Your trusted partner in process instrumentation Products Overview Your trusted partner in process instrumentation Process monitoring, alarm and shutdown applications World class technical solutions proven technology meeting international standards Pressure

More information

Ultrasonic Level Measurement nivopuls FDU 10 S

Ultrasonic Level Measurement nivopuls FDU 10 S Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous

More information

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry. Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV Answers for industry. 3 Many years of experience and state-of-the-art technology for highest performance Siemens has 30 years

More information

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH4 C3H8 H2 Gas leak testing Over and over again, devastating explosions and fires are caused

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Compressed air treatment. Condensate drains OMEGA AIR

Compressed air treatment. Condensate drains OMEGA AIR Compressed air treatment 77 Condensate drains OMEGA AIR 78 Condensate drains EMD SERIES ELECTRONIC CONDENSATE DRAIN drain capacity inlet connection 16 bar 12 l/h 1/2 1,5 to 65 C air compressor (piston

More information

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS SITRANS LR 400 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 400

More information

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME. PROCESS AUTOMATION K-SYSTEM THE MOST TRUSTED NAME PROCESS AUTOMATION PROTECTING YOUR PROCESS THE SYSTEM ELECTRONICS Availability: Power feed modules for a simplex or redundant supply on Power Rail Transmission

More information

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval) Gas Analysis Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with Condensate accumulates when conditioning gas in gas conditioning. It always accumulates when cooling moist sample gas. On

More information

Bristol Babcock Oil Content Monitor "oil in water"

Bristol Babcock Oil Content Monitor oil in water NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General