Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE. What You Measure, We Manage
|
|
- Daniela Singleton
- 5 years ago
- Views:
Transcription
1 Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE What You Measure, We Manage
2 ABOUT US ABOUT US DRM Technic is a global manufacturer and supplier of gas analysis solutions and gas detection products. We provide expert solutions to our clients which range from small independents to global manufacturers. We offer unrivalled customer service which is supported by our unique guarantee, and implemented by our valued, motivated and skilled team. We believe in quality, honesty and reliability. It is our vision to be our customers preferred full service provider (including installation, spares and service) and to create and maintain strong, valued and trusted relationships with all of our customers. PURCHASE OPTIONS We accept cheques, credit/debit cards and electronic bank payments. We also offer monthly credit accounts, subject to status. We are an established exporter and are pleased to offer a complete export service for our large product range. We can export our products worldwide. CONTACT DETAILS Address: DRM Technic Ltd, 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB, UK Telephone: +44 (0) sales@drmtechnic.com 2
3 Heated Sample Lines Contents CONTENTS Probe Finder 4 GAS GAS GAS GAS ATEX 8 GAS ATEX 2 9 GAS GAS ATEX 11 GAS ATEX 2 12 GAS GAS ATEX 14 GAS ATEX 2 15 GAS GAS ATEX 17 GAS ATEX 2 18 RSS 24 / RSS 230 Blowback Controllers 19 GAS 222 Accessories 20 3
4 PROBE FINDER Non-Hazardous Areas Both Hazardous Areas Dust Concen. Filter Type Heated; Self-Regulated Heated; Regulated Unheated Heated Zone 1 Heated Zone 2 Max Process Temp. Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 200 o C GAS GAS GAS GAS ATEX GAS ATEX 2 Up to 2 g/m 3 downstream filter GAS GAS GAS GAS ATEX GAS ATEX o C - - Steam Heated GAS DH - - > 2 g/m 3 in-situ filter - GAS GAS GAS ATEX GAS ATEX O C > 2 g/m 3 in-situ and downstream filter - GAS GAS ATEX GAS ATEX o C > 2 g/m 3 easy remove in-situ filter - GAS GAS U GAS ATEX GAS ATEX o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 120 o C > 2 g/m 3 in-situ filter - - ECO o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 600 o C > 2 g/m 3 in-situ filter - - APO o C 4
5 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated for applications with specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated with Downstream Filter Easy Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature +180 C (Self-regulating) Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 5
6 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated to application specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Self-Regulating Up to 180 C with Low Temperature Alarm For Dust Concentrations of Up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature Self-regulating; +180 C Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 6
7 DRM Technic -- Sample Probes -- Sample Probes GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temp. Alarm & Display Easy Filter Replacement Effective Insulation and Protection Shield For Dust Concentrations up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class - IP54 Ambient Temp C 7
8 GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Downstream Filter, Weather Protection Shield and Junction Box Easy Filter Element Replacement C-US and CSA Approval For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS ATEX SS Graphite, SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60 Hz Type C: External Circuit Breaker 2A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature -20 to 50 C Temperature Self-regulating; approx. 80 C Ex-marking of the basic unit 1 GD / 2 GD T4 T130 C 8
9 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Downstream Filter and Weather Protection Shield Effective Insulation and Protection Shield For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Specified for Use in Hazardous Areas Product No. GAS ATEX SS Graphite, SS + filter elements Heater V, 50/60 Hz Temperature Self-regulating; C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3 3G c IIC T3 II 3G EEx na L IIC T4 3G c IIC T4 9
10 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Shut Off Valve, alongside an In-Situ and/or Downstream Filter Tool-less Downstream Filter Element Replacement Effective Insulation and Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS; ball valve: SS PTFE, Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 10
11 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ / Downstream Filter and Weather Protection Shield Tool-less Filter Replacement Self-Regulating at up to 90 C For Dust Concentrations of up to 2 g/m³ with In-Situ Filter and 10 g/m³ with In-situ and Downstream Filters ATEX Certified Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS ATEX SS; ball valve: SS PTFE, Graphite, SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C External Circuit Breaker Type C: 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ and/or downstream Ex-marking of the Basic Unit. 1 GD / 2 GD T4 T130 C 11
12 GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, plus an In-Situ and/or Downstream Filter Easy Tool-less Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating at up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ ATEX Certification Product No. GAS ATEX SS ball valve: SS Graphite, SS + filter elements Temperature Self-regulating; 130 C (T3) / 70 C (T4) Low Temperature Alarm Contact is open at operating temp.; closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Pressure Shut-Off Valve 6 to 8 bar Suitable for II 3G EEx na L IIC T3; 3G c II C T3; II 3G EEx na L IIC T4; 3G c IIC T4 12
13 DRM Technic -- Sample Probes -- Sample Probes GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS; ball valve: SS PTFE, Graphite, SS Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 13
14 GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, Internal Filter and Weather Protection Shield Self-Regulating at Up to 90 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX ; ball valve: PTFE, Graphite, SS Max. Flow Rate 1000 l/h Max. Inlet Tempertature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C Type C: External Circuit Breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 14
15 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Self-Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX SS; ball valve: SS PTFE, Graphite and SS Self-regulating; Temperature C (T3) / + 70 C (T4) Contact is open at operating temperature; closes at < 95 C (T3) Low Temperature Alarm resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3; 3G c IIC T3; Suitable for II 3G EEx na L IIC T4 ; 3G c IIC T4 15
16 GAS GAS SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Tool-less Filter Replacement Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS SS Graphite, SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Range 50 to 200 C Adjustable; K from Alarm set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp C 16
17 DRM Technic -- Sample Probes -- Sample Probes GAS ATEX GAS ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ Filter and Weather Protection Shield Tool-less Element Replacement Self-Regulating at Up to 80 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX PTFE, Graphite, SS + filter elements Max. Flow Rate 1000 l/h Max. Inlet Temperature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 80 C Type C: External circuit breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 17
18 GAS ATEX 2 GAS ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Self- Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS ATEX SS PTFE, Graphite, SS + filter elements Voltage V, 50/60 Hz Temperature Self-regulating; C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Suitable for II 3G EEx na L IIC T3; 3G c IIC T3; II 3G EEx na L IIC T4; 3G c IIC T4 18
19 DRM Technic -- Sample Probes -- Sample Probes RSS 24 / RSS 230 Blowback Controllers RSS 24 / RSS 230 BLOWBACK CONTROLLERS The Blowback Controllers RSS 24 and RSS 230 are meant for controlling the cleaning cycles of a probe filter. They are designed for use with probe types GAS , GAS and ECO-01, but may also be used to control other external valves. Programmable Blowback / Sample Time Status Control Wall Mounted Product No. RSS 24 RSS 230 Power Supply 24 V DC ± 10% V AC 50/60 Hz Fuse 5 A (slow) 1 A (slow) Relais Output Max. 10 A / 24 V DC / 75 W Max. 10 A / 230 V AC / 690 VA Ambient Temperature 0-55 o C 0-55 o C Blowback Time 0-60 s 0-60 s Sample Time 1 min - 99:59 h 1 min - 99:59 h Protection Class IP 65 IP 65 Weight Approx. 3 kg Approx. 3 kg Dimensions (H x W x D mm) 300 x 300 x x 300 x 180 TIME FLOW DIAGRAM For more information, please feel free to contact our sales department 19
20 GAS 222 Sample Probe Accessories GAS 222 SAMPLE GAS PROBE ACCESSORIES We have a large range of Accessories for GAS 222 Sample Gas probes. See below for our Blowback Accessories, including Capacitive Vessels, Pneumatic Actuators, 3/2-way Solenoid Valves and Blowback Controllers. Overleaf are the details of our Sample Tubes, In-Situ Filters, Protection Sheilds and Extensions, all available in various materials, in various dimensions, and as heated and non-heated versions. 20
21 DRM Technic -- Sample Probes -- Accessories GAS 222 Sample Probe Accessories 21
22 DRM Technic Ltd 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB United Kingdom Tel: +44 (0) sales@drmtechnic.com
SITRANS F M MAG 3100 P:
Dedicated for the chemical industry SITRANS F M MAG 3100 P: The electromagnetic flowmeter solution with devoted features. Process Instrumentation usa.siemens.com/mag The best choice for the chemical industry
More informationOilSET-1000 (12 VDC)
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationDräger Polytron Pulsar 2 Detection of flammable gases and vapours
Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard
More informationGas cooler series TC-Standard+ X2
Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control
More informationPROFIBUS-PA Display RID 261 PROFIBUS-PA
Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationDräger Polytron 7000 Fixed gas detector
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and
More informationATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas
Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com Danfoss controls tailored for use in hazardous
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration
Level Measurement Siemens AG 2012 Overview Configuration Installation Standpipes 0 (2) 20 (0.79) max. is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces,
More informationSET-2000 Hi Level/Oil
Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47
More informationInstallation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit
EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS ABB The Company We are an established world force in the design and
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationDräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger X-am 3000 ST-2881-2003 Dräger X-am 3000 is an innovative 2 to 4 gas warning-device. This small and lightweight instrument
More informationDräger Polytron Pulsar 2 Open Path Gas Detector
Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationLevel Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
Siemens AG 00 Overview Configuration Installation Standpipes 0 () 0 (0.79) max. Wall Restriction is a compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces,
More informationHazardous Area Zirconia Oxygen Systems
Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationMSM400 Ultrasonic Suspended Solids Monitoring and Control System
Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either
More informationSET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions
SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationTechnical Specification VFD
Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and
More informationPANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent
More informationQUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions
QUANTURA DISHWASH DOSING SYSTEMS revolutionary dispensing solutions QUANTURA BRIGHTWELL DISPENSERS NEW RANGE OF DISHWASH DOSING SYSTEMS Reliable and efficient chemical dosing systems ensure that commercial
More informationIR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance
IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The
More informationData Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)
Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X
Installation Instructions P/N MMI-20010174, Rev. A June 2007 ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X For ATEX-approved sensor installations
More informationSample Gas Probes Series GAS 222
Sample Gas Probes Series GAS 222 A comprehensive range of basis units heated (selfregulating, regulated, steam) unheated probes for hazardous areas Zone 1 or 2 in-situ or downstream filters high dust concentration
More informationBuilding Services Brochure
Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving
More informationDräger Polytron 5720 IR Detection of carbon dioxide
Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high
More informationII 1G EEx ia IIC T4 T a = -20ºC to +60ºC
Microview Compact ATEX Hygrometer II 1G EEx ia IIC T4 T a = -20ºC to +60ºC MCM s ATEX On-Line Hygrometer Redefines Hazardous Area Applications! Continuous on-line analysis or incorporate the Microview
More informationCondensate drains WA/PWEA
Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationBKA-EN Fire Damper. Additional operating instructions according to
Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet CMB_PDS_340AC_AutoCal Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Can be easily
More informationAPI Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -
API Marine Sensors Presentation Mission critical applications in harsh environment - API - Acoustic Precise Instruments - API Marine API Marine - Acoustic Precise Instruments Development, design and production
More informationCertification Supplement Manual
SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN
More informationRotameter series 250 metal tube variable area flowmeter
Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems
HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and
More informationMaglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY
Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only
More informationBSK-RPR Fire Damper. Additional operating instructions according to
Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01
More informationDP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids
UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au
More informationEXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT
EXPLOSION PROTECTION Experts in Equipment for Explosive Atmospheres Ex SPECIALISTS TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT LIGHTING Portable, Temporary & Fittings Hazardous area lighting and
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationSENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT
SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT API MARINE Acoustic Precise Instruments Development, design & production of advanced tank sensors and automation systems for marine
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR
ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationAUDIBLE SIGNALIZATION
01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency
More informationMICROSENSE FLOW SWITCH
MICROWAVE FLOW SWITCH Elec Iss. 03 MICROSENSE FLOW SWITCH FOR SOLIDS, GRANULES AND POWDERS MICROSENSE - PRINCIPLE OF OPERATION The Microsense microwave switch provides an effective way of detecting the
More informationDESCRIPTION. 42 mm. 125 mm
RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller
More informationPOINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001
POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationDM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex
DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationDual-point heat-tracing control system
Dual-point heat-tracing control system 920*E4FWL*SIS302*SS3102 shown Product overview The Raychem 920 is a compact, full-featured, microprocessor-based, dual-point heat-tracing control system. The 920
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration
Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationGas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:
Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationLabkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
More informationZircomat Oxygen Analyzers
Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationInstrumentation Products and Applications
1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems
More informationPac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control
Pac Ex 2 Elegant and smart Explosive hazards and lack or surplus of oxygen under control Portable instruments protecting people against explosive hazards and lack or surplus of oxygen are used in a large
More informationInstrumentation for Nuclear Applications
Instrumentation for Nuclear Applications Nuclear Instrumentation Overview Delta Controls has been designing and manufacturing instrumentation for the power and process industries for over 65 years and
More informationDP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids
Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5
More informationPOWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators
POWERVAP - EX GENSER Scientific Instruments GERMANY NOW AVAILABLE High performance PTFE-sealings for all glass connectors Loss of pressure of the complete system < 2 hpa/h (system empty) Also available
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationContinuous level measurement Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationCOMPACT FLAME CONTROLLER CFC 1000
COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationKHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC
Thermocouple trip amplifiers KHA6GT*Ex1 23 V AC 1channel Input EEx ia IIC Cold junction compensation 2 switching points operate on 2 output relays High/low alarm can be selected for each switching point
More informationRAYCHEM NGC-30 COMPONENTS
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE
More informationGas cooler series RC 1.1
Gas Analysis Gas cooler series In the chemical industry, petrochemistry or biochemistry, reliable process control relies on prompt and exact determination of the operating parameters. Here, gas analysis
More informationEnraf Servo Gauge 854 XTG
Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationRod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids
Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks
More informationINSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE
INSTRUCTION MANUAL Change Over Unit ECO for ETC 24R MOBATIME BE-800356.00 Certification of the Producer STANDARDS The device has been developed and produced in accordance with the EU Standards 89 / 336
More informationLevel instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration
Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous
More informationPortable sample gas conditioning PCS.smart+
Gas Analysis Portable sample gas conditioning PCS.smart+ Carrying out accurate and reliable gas analyses in changing locations requires a small, compact gas conditioning system. We developed a complete
More informationProducts Overview. Your trusted partner in process instrumentation
Products Overview Your trusted partner in process instrumentation Process monitoring, alarm and shutdown applications World class technical solutions proven technology meeting international standards Pressure
More informationUltrasonic Level Measurement nivopuls FDU 10 S
Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous
More informationGas cooler series TC-Standard+
Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control
More informationAccurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.
Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV Answers for industry. 3 Many years of experience and state-of-the-art technology for highest performance Siemens has 30 years
More informationGas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex
Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH4 C3H8 H2 Gas leak testing Over and over again, devastating explosions and fires are caused
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationCompressed air treatment. Condensate drains OMEGA AIR
Compressed air treatment 77 Condensate drains OMEGA AIR 78 Condensate drains EMD SERIES ELECTRONIC CONDENSATE DRAIN drain capacity inlet connection 16 bar 12 l/h 1/2 1,5 to 65 C air compressor (piston
More informationRadar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS
Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS SITRANS LR 400 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 400
More informationPROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.
PROCESS AUTOMATION K-SYSTEM THE MOST TRUSTED NAME PROCESS AUTOMATION PROTECTING YOUR PROCESS THE SYSTEM ELECTRONICS Availability: Power feed modules for a simplex or redundant supply on Power Rail Transmission
More informationPeristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)
Gas Analysis Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with Condensate accumulates when conditioning gas in gas conditioning. It always accumulates when cooling moist sample gas. On
More informationBristol Babcock Oil Content Monitor "oil in water"
NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General
More informationPEPPERL+FUCHS GmbH
Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction
More informationRittal roof-mounted fans Efficiency on top
Rittal roof-mounted fans Efficiency on top 2 Climate control/roof-mounted fans The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled our
More information