Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
|
|
- Alannah Marsh
- 5 years ago
- Views:
Transcription
1 Siemens AG 00 Overview Configuration Installation Standpipes 0 () 0 (0.79) max. Wall Restriction is a compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits Easy installation with verification by built-in LED Low maintenance with no moving parts Sensitivity adjustment Integrated cable or PBT enclosure versions available Intrinsically Safe, Dust Ignition Proof and General Purpose options available 0 () 0 () min. Application s short insertion length of 00 mm (4") and versatility in various applications and in vessels or pipes makes it a good replacement for traditional capacitance sensors. Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] is chemically resistant with an effective process operating temperature range from -30 to +00 C (- to + F) (7ML0, and -0 to +00 C (+4 to + F) (7ML60). The fully potted design ensures reliability in a vibrating environment such as agitated tanks up to 4 g. When used with a SensGuard protection cover, the CLS00 is protected from shearing, impact and abrasion in tough primary processes. The is available in three versions. The integral cable version has a stainless steel process and probe options of PPS or PVDF. The fully synthetic version has a thermoplastic polyester enclosure with a PPS process combined with a PPS probe. The standard enclosure version has a thermoplastic polyester enclosure with a stainless steel process in combination with a PPS or PVDF probe. Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas installation, dimensions in mm (inch) /0 Siemens FI 0 0
2 Siemens AG 00 Level Measurement Technical specifications Stainless steel process (integral cable or enclosure version) (7ML0 Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measu variable Change in picofarad (pf) Output Output signal Alarm output 4 or 0/0 or 4 ma -wire loop Switch output Solid-state: 30 V DC/ 30 V AC, max. 8 ma Fully synthetic process (enclosure version only) (7ML60) Inverse frequency shift capacitive level detection Change in picofarad (pf) 4 or 0/0 or 4 ma -wire loop Max. switching voltage: 60 V DC/30 V AC Max. switching current: A Fail-safe mode Min. or max. Min. or max. Accuracy Repeatability mm (0.08") mm (0.08") Rated operating conditions ) Installation conditions Location Indoor/outdoor Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category I C ( F) I Pollution degree 4 4 Medium conditions Relative dielectric contant ε r Min.. Min.. Process temperature C ( F) Pressure (vessel) bar g ( psi g), ) Degree of protection C ( F) bar g ( psi g), - Enclosure version IP68/Type 4/NEMA 4 IP68/Type 4/NEMA 4 - Integral cable version IP6/Type 4/NEMA 4 Cable inlet ½" NPT (M0x. optional) ½" NPT (M0x. optional) Design Enclosure/Integral Fully synthetic version cable version Material Body Lid Integrated cable body (Integral cable version) Sensor length () Thermoplastic polyester Transparent thermoplastic polycarbonate (PC) 36L stainless steel Thermoplastic polyester Transparent thermoplastic polycarbonate (PC) 00 mm (4") 00 mm (4") Process material of probe/wetted parts 3) Connection Connection (Integral cable version) Process Stainless steel process (integral cable or enclosure version) (7ML0 Connection: 36L stainless steel; Process seal: FKM (optional FFKM); Sensor: PPS (optional PVDF) 4) Internal -point terminal block, ½" NPT wiring entrance, M0x. optional 4 conductors, m (3.3 ft), 0. mm² ( AWG), shielded, polyester jacket ¾" NPT [(Taper), ANSI/ASME B.0.] R " [(BSPT), EN 06/PT (JIS-T), JIS B 003] G " [(BSPP), EN ISO 8-/PF (JIS-P), JIS B 00] Fully synthetic process (enclosure version only) (7ML60) PPS process and PPS sensor (Uni-Construction) Removable internal -point all one word, ½" NPT wiring entrance, M0 x. optional ¾" NPT [(Taper), ANSI/ASME B.0.] R " [(BSPT), EN 06/PT (JIS-T), JIS B 003] Power supply Standard V DC V DC Intrinsically Safe V DC (Intrinsically Safe barrier requi) Certificates and General: CE, CSA, FM, General: CSA, FM approvals C-TICK Marine: Lloyds Register of Shipping, categories ENV, ENV, and ENV Dust Ignition Proof (barrier requi): CSA/FM Class II and III, Div., Groups E, F, G T4 Intrinsically Safe (barrier requi): CSA/FM Class I, II and III, Div., Groups A, B, C, D, E, F, G T4 ATEX II GD /GD EEx ia IIC T4 to T6 T07 C Overfill protection: WHG (Germany) When synthetic process version (7ML60) is used in wet locations, switching voltage of the relay is limited to 3 V DC/6 V AC. ) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /3. 3) For Caustic Materials please contact nacc.smpi@siemens.com for alternative O Rings. 4) When FFKM O-ring (Option A) is selected, process temperature is restricted to -0 C (-4 F). Siemens FI 0 0 /
3 Siemens AG 00, stainless steel process Compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam Process C) 7 M L ¾" NPT [(Taper), ANSI/ASME B.0.] A R " [(BSPT), EN 06/PT (JIS-T), JIS B 003] E G " [(BSPP), EN ISO 8-/PF (JIS-P), J JIS B 00] Approvals General Purpose: CE, CSA, FM, C-TICK A CSA/FM Class I, II and III, Div., Groups A, B, C, D, C E, F, G T4; ATEX II GD /GD EEx ia IIC T4 to T6 T07 C CSA/FM Class II and III, Div., Groups E, F, G G Device version Integral cable version (PPS probe) Enclosure version (PPS probe), ½" NPT cable inlet 3 Integral cable version with PVDF probe body Enclosure version with PVDF probe body 6 (½" NPT cable inlet) Enclosure version (PPS probe), 7 M0x. cable inlet Enclosure version with PVDF probe body, 8 M0x. cable inlet WHG approval, German overfill protection Not requi 0 Requi Barrier or Intrinsically safe power supply requi for Intrinsically Safe protection C) Subject to export regulations AL: N, ECCN: EAR99 Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [3 x 4 mm (0. x.7")]: Measuring-point number/identification (max. 0 characters) specify in plain text FFKM seal O-ring Inspection Certificate Type 3. per EN 004 Operating Instructions Quick start manual, multi-language Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing ATEX Quick Starts and Operating Instructions. Optional equipment Sensguard, ¾" NPT (PPS) Sensguard, R " (BSPT) (PPS) Siemens Intrinsically Safe Barrier (DC powe), ATEX II G EEx ia ½" NPT cable gland, nickel plated brass, fits cable diameter 6... mm ( ") C ( F), IP68 (General Purpose) M0x. cable gland, PA polyamide, ATEX II G EEx e II, fits cable diameter 7... mm ( "), C ( F), IP68 (General Purpose) Order code Y7 A C 7ML998-QJ8 7ML830-DL 7ML830-DM 7NG4-AA0 7ML830-JA 7ML830-JC, PPS process Compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam Process (PPS) ¾" NPT [(Taper), ANSI/ASME B.0.] (PPS probe body) R " [(BSPT), EN 06/PT (JIS-T), JIS B 003] (PPS probe body) Approvals General Purpose: CSA, FM Versions/Options Enclosure version, PPS process, ½" NPT cable inlet Enclosure version, PPS process, M0x. Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [3 x 4 mm (0. x.7")]: Measuring-point number/identification (max. 0 characters) specify in plain text FFKM seal O-ring Inspection Certificate Type 3. per EN 004 Operating Instructions Quick start manual, multi-language Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing ATEX Quick Starts and Operating Instructions. Optional equipment Sensguard, ¾" NPT (PPS) Sensguard, R " (BSPT) (PPS) See Temperature restriction on page /3 Options Optional Sensguard Internal thread ¾" NPT 3 (.6) 9 (3.6) Process ¾" NPT 70 (.7) 3 (.6) 9 (3.6) Optional Sensguard, dimensions in mm (inch) C) 7 M L A B D Order code Y7 A C 7ML998-QJ8 7ML830-DL 7ML830-DM Process R " (BSPT) 70 (.7) See Temperature restriction on page /3 / Siemens FI 0 0
4 Siemens AG 00 Level Measurement Characteristic curves Pressure/Temperature Curve CLS00 Threaded Process Connections (7ML0 Permitted Operating Pressure P 30 bar (43 psi) 0 bar (90 psi) atmospheric - bar (-4. psi) -0 ºC (-38 ºF) -00 ºC (-48 ºF) 0 bar (4 psi) -0 ºC (-8 ºF) Example: Permitted operating pressure = 0 bar (4 psi) at 7 C - ºF 4 ºF (-30 ºC) (-0 ºC) -9 ºC (-0 ºF) 00 ºF (38 ºC) 00 ºF (93 ºC) 0 ºC RT 0 ºC 00 ºC (3 ºF) ( ºF) ( ºF) 300 ºF (49 ºC) 0 ºC (30 ºF) 400 ºF (04 ºC) 00 ºC (39 ºF) Permitted Operating Temperature T Process Pressure/Temperature derating curves Dimensional drawings Integral Cable Version Enclosure Version 80 (3.) Ground post Power LED (green) Sensitivity trimpot Cable Ø (0.) Trimpot cap 0 (4.7) 0 (.0) 36 (.4) * Cable relief Output status LED () Sensor status LED (yellow) 98 (3.9) Process Power LED (green) Sensitivity trimpot Sensor status LED (yellow) Output status LED () Process 98 (3.9) (.6) 7. (.9) 0 (4.7) Cable inlet ½ NPT (optional M0x.) 04 (8.0) Terminal block ground lug *Some G thread configurations deviate from this size., dimensions in mm (inch) Siemens FI 0 0 /3
5 Schematics Siemens AG 00 Integral Cable Version - Non Intrinsically Safe only LOW/HIGH Alarm Polarity as requi for desi operation 4 to 0 ma Loop Alarm Rmax = Vsupply - 0 V 0 ma Solid State Switch Version V supply Solid state switch, 30 V DC/AC (peak) 8 ma (max) Enclosure and Fully Synthetic Version 3 4 V supply Terminal operations Cable equivalent ma current loop (+V or -V) wire ma current loop (+V or -V) wire ground cable shield solid state switch / relay* wire solid state switch / relay* wire Note: * switch/relay normally open in unpowe state * relay not available on IS version (7ML0 When driving an inductive load (for example, an external relay), a protection diode must be connected in the correct polarity to prevent possible switch damage due to inductive spikes generated by switching the inductor (please refer to instruction manual). Intrinsically Safe Models - please follow local regulations and area classifications; refer to instruction manual for more details. s /4 Siemens FI 0 0
Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration
Level Measurement Siemens AG 2012 Overview Configuration Installation Standpipes 0 (2) 20 (0.79) max. is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces,
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration
Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationQuick Start Manual July pointek CLS100
Quick Start Manual July 2009 pointek CLS100 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationLevel instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration
Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous
More informationContinuous level measurement Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationContinuous level measurement - Radar transmitters
Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationPOINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001
POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationLevel Measurement Continuous level measurement Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationPOINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001
POINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual December 2001 OINTEK CLS 200 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to
More informationUltrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics
Ultrasonic switch Pointek ULS200 Quick Start Manual 03/2013 Milltronics Pointek ULS200 Quick Start Manual This manual outlines the essential features and functions of Pointek ULS200. We strongly advise
More informationMSM400 Ultrasonic Suspended Solids Monitoring and Control System
Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either
More informationFlow Measurement SITRANS F C
Overview The compact flowmeter SITRANS FC410 can be ordered for industrial, hygienic or NAMUR service. Intended for integration into OEM skids, machines or pre-assembled plant systems, the flowmeter is
More informationProcess Protection. 6/2 Product overview. 6/3 Acoustic and Motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400
Siemens AG 2013 /2 Product overview /3 Acoustic and Motion sensing Acoustic sensors for pump monitoring /5 Acoustic sensors for material flow monitoring /10 SITRANS AS100 /14 SITRANS CU02 Motion sensors
More informationM-Switch Float Operated Liquid Level Switch
Product Data Sheet M-Switch Float Operated Liquid Level Switch Reliably detects the liquid level to give a voltage free contact operation for alarm signalling or as part of a pump control system Small
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationOilSET-1000 (12 VDC)
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009
More informationPOINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001
POINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual December 2001 OINTEK CLS 300 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to
More informationProcess Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit
Siemens AG 2017 /2 Overview /3 Acoustic and motion sensing Acoustic sensors for pump monitoring /5 SITRANS DA400 acoustic diagnostic unit Acoustic sensors for material flow monitoring /10 SITRANS AS100
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationMEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2
APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,
More informationMobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters
Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version
More informationIntrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter
PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma
More informationSET-2000 Hi Level/Oil
Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve
More informationCable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationRosemount 3100 Series Ultrasonic Level Transmitters
Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.
More informationSITRANS F M MAG 3100 P:
Dedicated for the chemical industry SITRANS F M MAG 3100 P: The electromagnetic flowmeter solution with devoted features. Process Instrumentation usa.siemens.com/mag The best choice for the chemical industry
More informationPage. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller
Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA 18974 Phone: 267-673-8117-800-352-6265; Fax: 267-673-8118 Sales@cabriggs.com - www.cabriggs.com Page 1-2 Sepra-Lite Integral Optic
More informationMEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications
MEAS 5700 Subermsible Liquid Level Pressure Transducer Features Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.25% Accuracy
More informationSpecifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]
Series PMT2 Particulate Transmitter Specifications - Installation and Operating Instructions Bulletin PC-PMT2 2X 1/2 NPT OR M20 ELECTRICAL ENTRY THREADED MOUNT Probe A Length in [mm] 3 3 [76.20] 5 5 [127.00]
More informationDifferential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50
Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases
More informationSET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions
SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationT500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors
Plant Wide Monitoring System for Bucket Elevators & Conveyors APPLICATION Combined belt alignment, belt speed, continuous bearing temperature, pulley alignment, level and plug condition monitor for bucket
More informationitemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter
BA 104R/24/ae/10.03 itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter Operating instructions RTD TC TMT 187 TMT 188 Temperature head transmitter Safety message # Warning! Instructions and
More informationEnraf Servo Gauge 854 XTG
Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationRosemount 3100 Series Ultrasonic Level Transmitters
Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.
More informationData Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)
Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display
More informationPOINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002
POINTEK ULS 200 ULTRASONIC LEVEL SWITCH Instruction Manual August 2002 O Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product
More informationCable Glands DB Series: Drain, Breather Valves and Unions
DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationRosemount 3490 Series
Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall
More informationHazardous Area Zirconia Oxygen Systems
Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationRod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids
Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationRF Admittance Technology FACTS
RF Admittance Technology FACTS Each year RF Admittance is the most purchased technology offered in electronic point level products Versatile technology, well proven in a wide range of applications in solid,
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationU5700 Submersible Liquid Level Pressure Transducer
SPECIFICATIONS High Accuracy CE Compliant and Waterproof UL Certified Variety of Pressure Port Configurations Waterproof Optional Stainless Steel Snubber IP68 Rated Connection and Submersible Polyurethane
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationRadar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS
Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS SITRANS LR 400 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 400
More informationDL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications
DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed
More informationDifferential Pressure and Flow Meter Media 5 Indicator 160 PN 40
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationIntroduction to Flow Switch
Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal
More informationInstallation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit
EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS ABB The Company We are an established world force in the design and
More informationABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)
Flame scanner for gas and oil burners (Rev. B) Application: - Wall fired boilers - Gas and oil burners High sensitive UV tube Continuous self-checking Rugged detector head for harsh environments: - Protection
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationMobrey MCU900 Series Universal Control Unit
Universal Control Unit Intrinsically Safe power supply to transmitter 4 20mA HART input Isolated 4 20mA output Five control relays Multi-function back lit display Wall or panel mount Pre-programmed linearization:
More informationFAHM Co. Temperature Transmitter PTT74 Series
FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters
More informationEnraf Servo Gauge 854 ATG
Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over
More informationM5800 Pressure Transducer with Rotatable Display
Pressure Transducer with Rotatable Display SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and customized Electrical Configurations FEATURES CE Compliance Reverse Polarity Protection
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 2708418 Issued to: Gems Sensors Inc. 1 Cowles Road Plainville, CT 06062 USA Attention: Mr. Philip I. Draper The products listed below are eligible to bear
More informationUltrasonic Point Level Switches
see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded
More informationINTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTION / TABLE OF CONTENTS Step One Offered in liquid and gas sensor types, the general purpose flow switch provides reliable low or no flow detection of relatively clean, non coating media with
More informationDräger Polytron 7000 Fixed gas detector
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and
More informationOperating Instructions Edition 02/2007
Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter
More informationABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.
Flame scanner for fuel oil and coal flame (rev. A) Application: - Wall fired, corner fired and down-shot boilers - Oil, Orimulsion and pulverized coal burners PbS sensor to detect flame by infrared (IR)
More informationLEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET F170 - LEVEL MONITOR
LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET LEVEL MONITOR Features Displays level and percentage filled. 4 alarm values can be entered: lowlow, low, high and highhigh level alarm.
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)
Dual sensor flame scanner (rev B) Application: - Wall fired and corner fired boilers - Gas, oil and coal multi-fuel burners Combined PbS IR sensor and high sensitivity UV tube Continuous self-checking
More informationINSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm
More informationInductive Conductivity
Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays
More informationRosemount 2100 Series
Rosemount 2100 Series Vibrating Fork Liquid Level Switches Level switches for demanding applications Reliable performance... Rosemount 2100 series vibrating fork level switches are suitable for virtually
More informationINSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm
More informationL+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4
Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors
More informationRosemount 752 Fieldbus Remote Indicator
Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,
More informationRosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016
Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationINTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400
Pressure Transducer / Transmitter AST4400 Overview The AST4400 is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and best price-toperformance ratio in
More informationMEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2
APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,
More informationNorth American Cable Glands
North American Cable Glands INTRODUCTION Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information
More informationIn order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.
Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity
More informationM5800 Pressure Transducer with Rotatable Display
Pressure Transducer with Rotatable Display SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and customized Electrical Configurations Optional Stainless Steel Snubber CE Compliant
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More information