Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

Size: px
Start display at page:

Download "Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85"

Transcription

1 Victaulic Vic-Flex Sprinkler Fittings Series H Braided Flexible Hose 0..0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,,, 0, "/0,, 0,, 0. Note: length includes adapter nipple and."/0 straight reducer. Sprinkler educers: ½" and ¾"/ and 0 sprinkler connections and."/0, "/0, "/0 straight lengths and short, long 0º elbows. Note: The short 0 elbow is typically used with concealed sprinklers while the long 0º elbow is typically used in the installation of recessed pendent sprinklers. dapter Nipples: "/ NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFP standards. ¾"/0 NPT or BSPT available for VdS. ¼"/ BSPT available for LPCB. Brackets: Style B for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place Style B for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style B for surface mount applications, wood, metal and block walls Style B for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style B for suspended and hard-lid ceilings Style B djustable for suspended and hard-lid ceilings Style B for hard-lid ceilings with CD 0/ profile metal studs (regionally available) Style B for hard-lid ceilings with hat furring channel grid systems Style B0 for rmstrong TechZone ceilings Maximum Working Temperature F/0 C Maximum Working Pressure 00 psi/ kpa (FM pproval) psi/0 kpa (culus Listed) 00 kpa/ psi (VdS/LPCB pproved) LWYS EFE TO NY NOTIFICTIONS T THE END OF THIS DOCUMENT EGDING PODUCT INSTLLTION, MINTENNCE O SUPPOT. System No. Location Spec Section Paragraph Submitted By Date pproved Date 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

2 .0 PODUCT DESCIPTION (Continued) Connections To adapter nipple (inlet) via "/. NPT or BSPT male thread O To adapter nipple (inlet) via ¾"/0 BSPT male thread(vds only) To sprinkler head (outlet) via ½" or ¾"/ or 0 Bend adius "/ (FM pproval) "/ (culus Listed) "/. (VdS/LPCB pproved) Maximum llowable Sprinkler K-Factors FM (½"/ reducer) K./, (S.I.), (¾"/0 reducer) K.0/0, (S.I.) culus (½"/ reducer) K.0/, (S.I.), (¾"/0 reducer) K.0/0, (S.I.) VdS/LPCB (½"/ reducer) K./, (S.I.), (¾"/0 reducer) K.0/, (S.I.).0 CETIFICTION/LISTINGS.0 SPECIFICTIONS MTEIL Series H Flexible Hose: 00-series Stainless Steel Collar/Weld Fitting: 00-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation ing: Nylon Nut and Nipple: Carbon Steel, Zinc Plated educer (½ or ¾"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

3 .0 DIMENSIONS Product Details - Series H Braided Hose B Flexible Hose Isolation ing Gasket Nut dapter Nipple Braid Collar/Weld Fitting Sleeve Hose Length s Hose Length B /0./ /0 /./ / /0./0 /0 0/./ 0/ /0./ /0 Standard educer Optional educers."/0 straight reducer.0"/ straight reducer.0"/0 straight reducer."/.."/.."/.."/. NOTE Short 0 elbow reducer Long 0 elbow reducer The Short 0 elbow reducer is typically used with concealed sprinklers while the longer 0 elbow is typically used in the installation of recessed pendent sprinklers. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

4 . DIMENSIONS VicFlex Brackets Style B Suspended Ceilings Hard-Lid Ceilings (FM Only) "/0 or "/0 Square Bar Patented Center Bracket End Bracket Both sizes FM/VdS/LPCB approved, culus listed Style B Suspended Ceilings Hard-Lid Ceilings "/0 or "/0 Square Bar Patent-Pending adjustable Center bracket End Bracket Both sizes FM/VdS/LPCB approved, culus listed Style B Surface Mount pplications FM pproved 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

5 . DIMENSIONS VicFlex Brackets Style B Hard-Lid Ceilings with Hat furring channel grid system "/0 or "/0 Square Bar Patent-Pending adjustable Center bracket End Bracket for Hat Furring Channel Both sizes FM/VdS approved, culus listed Style B Suspended Ceilings Hard-Lid Ceilings "/0 or "/0 Square Bar Patented -Bee Center Bracket End Bracket Both sizes FM/VdS approved. Style B djustable Suspended Ceilings Hard-Lid Ceilings 00 or 00 Square Bar Patented -Bee Center Bracket End Bracket (adjustable) Both sizes FM/VdS approved. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

6 . DIMENSIONS VicFlex Brackets Style B Hard-Lid Ceilings 00 or 00 Square Bar Patent-pending adjustable center bracket Both sizes FM/VdS Both sizes FM/VdS approved. Style B Hard-Lid ceilings with Hat furring channel grid system "/0 or "/0 Square Bar Patented -Bee Center Bracket End Bracket for Hat Furring Channel Both sizes FM/VdS approved. Style B0 Suspended ceilings rmstrong TechZone "/ Square Bar Patented -Bee Center Bracket End Bracket FM/VdS approved, culus listed. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

7 . DIMENSIONS CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Suspended Ceiling Grid with ecessed Sprinkler Suspended Ceiling Grid with Concealed Sprinkler See Chart Style B See Chart."/ Typical ceiling grid See note /"/ Typical ceiling tile "/0 or "/ on Center V0 ¾"/ MX. ECESS."/ /"/0 "/ V0 MX. EXTENSION."/ Typical ceiling grid See note Bracket ssembly Style B /"/. Typical ceiling tile "/0 or "/ on Center V0 ½"/. MM MX. ECESS."/ /"/. /"/0. V0 MX. EXTENSION V0 ¾"/ Max. ecess V0 ½"/. Max. ecess Bend adius Bend adius Suspended Ceiling Grid with ecessed Sprinkler with 0 Elbow (Long) Suspended Ceiling Grid with Concealed Sprinkler with 0 Elbow (Short) See Chart."/ Typical ceiling grid Style B /"/ Typical ceiling tile."/ /"/0 "/ See Chart."/ Typical ceiling grid Bracket ssembly Style B "/ Typical ceiling tile."/ "/ "/0 See note "/0 or "/ on Center V0 ¾" / MX. ECESS V0 ¾"/ Max. ecess V0 MX. EXTENSION See note "/0 or "/ on Center V0 ½"/. Max. ecess ev X Updated /0 0 Victaulic Company. ll rights reserved.

8 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with ecessed Sprinkler " " Stud #0 Screw Style B."/ ¾"/ "/ " " Stud."/ #0 Screw Style B."/ "/0 "/."/ "/0 Stud C/C "/0 Stud C/C V0 ¾"/ MX. ECESS V0 MX. EXTENSION V0 ½"/. Max. ecess Bend adius V0 ¾"/ Max. ecess Bend adius NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. Hard-lid Ceiling Grid with Concealed Sprinkler with 0 Elbow (Short) Hard-lid Ceiling with ecessed Sprinkler with 0 Elbow (Long) " " Stud #0 Screw Style B."/ ¾"/ "/ " " Stud."/ #0 Screw Style B."/ "/0 "/."/ "/0 Stud C/C "/0 Stud C/C V0 ½"/. Max. ecess V0 ¾"/ Max. ecess. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

9 . DIMENSIONS CLENCES WITHIN SIDEWLL Series H Braided Hose and Style B Bracket Horizontal Sidewall Sprinkler Horizontal Sidewall Sprinkler with 0 Elbow (Long) " " Stud."/ #0 Screw Style B."/ "/0 "/ " " Stud."/ #0 Screw Style B."/ "/0 "/ sidewall face sidewall face "/0 Stud C/C "/0 Stud C/C V0 ¾"/ Max. ecess V0 ¾"/ Max. ecess Bend adius ev X Updated /0 0 Victaulic Company. ll rights reserved.

10 . DIMENSIONS CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Hat Furring Channel Grid with ecessed Sprinkler See Chart /"/0 "/ See note Typical "/0 "/0 on Center /"/. Typical ceiling tile /"/ Typical ceiling grid V0 ¾"/ Max. ecess Bend adius Hat Furring Channel Grid with ecessed Sprinkler with 0 Elbow (Long) Hat Furring Channel Grid with Concealed Sprinkler with 0 Elbow (Short) /"/ Typical ceiling tile See Chart /"/0 "/ /"/ Typical ceiling tile See Chart /"/0 "/ See note Typical "/0 "/0 on Center /"/ Typical ceiling grid See Note "/0 "/0 on Center /"/ Typical ceiling grid V0 ¾"/. MM MX. ECESS V0 ¾"/ Max. ecess V0 MX. EXTENSION V0 ¾"/ Max. ecess 00. NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved. 0

11 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Surface Mount pplication with ecessed Sprinkler C ¾"/. See Note B "/0 "/ Wall Thickness "" Hose Clearances Outlet Length "B" Hose Clearance "C" Bend adius "" 00 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. See installation instructions for mounting screw type and size ev X Updated /0 0 Victaulic Company. ll rights reserved.

12 .0 PEFOMNCE FICTION LOSS DT Series H Braided Hose with Straight." educers Style B, B, B, and B0 Brackets Series H Hose Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of "/. Sch. 0 Pipe (C=0) Maximum Number of 0 at "/ Bend adius / //type / ½"//Straight /. ¾"/0/Straight /. /00 ½"//Straight /. ¾"/0/Straight /.0 /00 ½"//Straight /. ¾"/0/Straight /. 0/00 ½"//Straight /.0 0 ¾"/0/Straight /.0 0 /00 ½"//Straight /. ¾"/0/Straight /. Series H Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 0 degree bends at "/ center line Length of Stainless Steel Flexible Hose Outlet Size Bend 0 / / / ½"/./..0/..0/.0.0/. N. N. N. N. N. N. N. N. ¾"/0 0.0/.0./..0/..0/. N. N. N. N. N. N. N. N. /00 ½"/./..0/..0/..0/..0/. N. N. N. N. N. N. N. ¾"/0.0/..0/../. 0.0/..0/.0 N. N. N. N. N. N. N. /00 ½"/./..0/../. 0.0/..0/..0/..0/..0/. N. N. N. N. ¾"/0.0/..0/../../..0/..0/. 0.0/..0/. N. N. N. N. 0/00 ½"/./..0/..0/../. 0.0/..0/..0/..0/..0/..0/.0 N. N. ¾"/0.0/.0.0/..0/../.0 0./..0/..0/..0/..0/..0/.0 N. N. /00 ½"/ 0.0/..0/../../. 0./..0/..0/..0/.0.0/..0/..0/..0/. ¾"/0.0/../..0/0../0. 0.0/. 0./..0/..0/.0 0.0/..0/..0/..0/. NOTES: Values for use with." straight reducers. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

13 . PEFOMNCE FICTION LOSS DT Series H Braided Hose Style B, B, B, B, B, B dj., B, B and B0 VicFlex Brackets Series H Hose Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of "/. Sch. 0 Pipe Maximum Number of 0 at "/ Bend adius FM NOTES: / Imperial/S.I. //type /./. ½"//Straight./. ½"//0 Elbow /.0 /00./. ½"//Straight./. ½"//0 Elbow./. /00./. ½"//Straight./. ½"//0 Elbow./. 0/00./. ½"//Straight./. ½"//0 Elbow /. /00./. ½"//Straight./. ½"//0 Elbow./. /.0/. ¾"/0/Straight 0./. ¾"/0/0 Elbow 0./. /00.0/. ¾"/0/Straight.0/. ¾"/0/0 Elbow./. /00.0/. ¾"/0/Straight./0. ¾"/0/0 Elbow./0. 0/00.0/. ¾"/0/Straight./. ¾"/0/0 Elbow 0./. /00.0/. ¾"/0/Straight./. ¾"/0/0 Elbow./. /./. ¾"/0/Straight./. ¾"/0/0 Elbow /. /00./. ¾"/0/Straight./. ¾"/0/0 Elbow./. /00./. ¾"/0/Straight./0.0 ¾"/0/0 Elbow./. 0/00./. ¾"/0/Straight./. ¾"/0/0 Elbow./. /00./. ¾"/0/Straight 0./. ¾"/0/0 Elbow./. /.0/0. ¾"/0/Straight./. ¾"/0/0 Elbow./. /00.0/0. ¾"/0/Straight./. ¾"/0/0 Elbow./. /00.0/0. ¾"/0/Straight 0./. ¾"/0/0 Elbow./. 0/00.0/0. ¾"/0/Straight./0. ¾"/0/0 Elbow./0. /00.0/0. ¾"/0/Straight./. ¾"/0/0 Elbow./. Series H has been tested and pproved by FM Global for use in wet, dry and preaction systems per NFP,, and D and FM data sheets -0, -, and -. FM and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. Differences in equivalent lengths are due to varying test methods, per FM and VdS standards. efer to these standards for additional information regarding friction loss test methods. EXMPLE: -inch hose installed with two 0 bends and two 0 bends at a -inch is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 0, which is less than the allowable ev X Updated /0 0 Victaulic Company. ll rights reserved.

14 . PEFOMNCE FICTION LOSS DT Series H Braided Hose Style B, B, B, B, B dj., B, B, and B0 Brackets Series H Hose Length of Stainless Steel Flexible Hose / / 00/ 00/ 00/0 00/ VDS CEILING MNUFCTUES LIST Outlet Size Equivalent Length of steel pipe according to EN 0 DN (, x,) Maximum Number of 0º at "/. Bend adius / type /feet /feet /½"/Straight 0 /¾"/Straight./.0 /½"/Straight 0 /¾"/Straight./.0 /½"/ Straight 0 /¾"/Straight./. /½"/Straight 0 /¾"/Straight 0./. /½"/Straight 0 /¾"/Straight./.0 B, B, B, B0 B/ B. MF. rmstrong. Chicago Metallic. Dipling. Durlum. Geipel. Gema-rmstrong. Hilti. Knauf 0. Lafarge. Linder. Odenwald. ichter. igips. ockfon Pagos. Suckow & Fischer. USG Donn No specific approval Series H Braided Hose Style B Bracket. Hilti. Knauf. Lafarge. Lindner. igips Series H Hose Series H Hose Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 0 DN (, x,) Maximum Number of 0º at "/. Bend adius Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 0 DN (, x,) Maximum Number of 0º at "/. Bend adius / //type /feet / //type /feet / /½"/Straight /½"/0º Elbow./.0 / 0 /¾"/Straight 0 /¾"/0º Elbow./. 00/ /½"/Straight /½"/0º Elbow./. 00/ 0 /¾"/Straight 0 /¾"/0º Elbow./. 00/ /½"/Straight /½"/0º Elbow./.0 00/ 0 /¾"/Straight 0 /¾"/0º Elbow./. 00/0 /½"/Straight /½"/0º Elbow./. 00/0 0 /¾"/Straight 0 /¾"/0º Elbow./. 00/ /½"/Straight /½"/0º Elbow./. 00/ 0 /¾"/Straight 0 /¾"/0º Elbow./. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

15 .0 NOTIFICTIONS WNING It is the responsibility of the system designer to verify suitability of 00-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on 00-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage..0 EFEENCE MTEILS CHCTEISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Three X X O O 0 NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. User esponsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recoendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property ights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recoendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms Patented or Patent Pending refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. ll products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation eference should always be made to I-VICFLEX-B-B-B0, I-VICFLEX-B-B, I-VICFLEX-B, or I-VICFLEX-B for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at Warranty efer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 0. ev X Updated /0 0 Victaulic Company. ll rights reserved.

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 Victaulic VicFlex Sprinkler Fittings Series H and H-CC Braided Flexible Hoses 0.8 Series H Series H-CC.0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,, 8, 0, "/90, 9, 9,, 80. Note:

More information

10.85 VicFlex Sprinkler Fittings

10.85 VicFlex Sprinkler Fittings Series AQB Braided Flexible Hose Assemblies VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing

More information

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic

More information

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Style Sprinkler Fittings for Surface Mount Applications INTRODUCTION WARNING Read and understand all instructions before attempting to install any

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6 INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Sprinkler Fittings: Style Bracket Assembly with Models V33,, or V40 Dry Sprinklers Read and understand all instructions before attempting to install

More information

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop

More information

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless

More information

VicFlex TM Stainless Steel Sprinkler Fittings

VicFlex TM Stainless Steel Sprinkler Fittings V i c t a u l i c f i r e p r o t e c t i o n s y s t e m s Fast, dependable installation up to 10x faster than rigid pipe Durable performance Cost-effective maintenance and retrofit VicFlex TM Stainless

More information

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available

More information

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The V3806 concealed, designer style sprinkler allows up to 1/4"/8 mm adjustment to accommodate concealment needs. The separate two-piece mounting cup/cover plate

More information

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response This concealed, designer style sprinkler allows up to 1/2"/13 mm adjustment to accommodate concealment needs. The standard design provides a consistent hemispherical spray pattern. The separate two-piece

More information

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 5.6 K-Factor will aid in the system

More information

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending FireLock LP-46 Low Pressure Storage Sprinkler This storage sprinkler was designed for controlling fires in single, double and multiple row rack storage of up to Cartoned, Unexpanded, Group A plastic commodities

More information

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V3426 residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 6.9 K-Factor will aid

More information

Discontinued Product

Discontinued Product SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve

More information

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions

More information

DISCONTINUED PRODUCT

DISCONTINUED PRODUCT SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 residential sprinklers are designed to meet the requirements of NFPA 13, 13D and 13R for residential use in a variety of room sizes, depending

More information

quick response Sprinkler 105a October 25, 2010

quick response Sprinkler 105a October 25, 2010 October 25, 2010 Sprinkler 105a 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall L C The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model

More information

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking dry vertical sidewall sprinklers are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems,

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a. September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction

More information

FLUSH HORIZONTAL SIDEWALL

FLUSH HORIZONTAL SIDEWALL The V36 dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model V36

More information

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date MEA: 276-99-E CSFM: 7770-0531:113 The Series 766 high pressure butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has been developed for fire pump metering

More information

Series 759 FireLock Alarm Check Valve

Series 759 FireLock Alarm Check Valve R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.70 Series 759 FireLock Alarm Check Valve Grooved Grooved PRODUCT DESCRIPTION U L FM U L C See Victaulic publication 10.01 for details. The Victaulic

More information

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS * * See page 2 for FM Approved product configurations SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 ECLH sprinklers are designed with a K14.0 orifice size to provide added coverage at normal

More information

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent Pendent, Level Pendent & Pendent The Model V36 Series Dry Type Pendent and Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special

More information

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL FLSH The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Models V3608 and

More information

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 standard spray sprinklers are designed to produce large discharge capacity in a hemispherical pattern standard in commercial applications.

More information

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL V3606 QICK RESPONSE The Model V36 Series Dry Type Pendent and Recessed Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special applications

More information

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers February 24, 2012 Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 211313 WET-PIPE SPRINKLER SYSTEMS PRT 1 GENERL 1.01 RELTED DOCUMENTS. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA Page 1 of 7 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems

More information

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

TRUST THE ORIGINAL. SUBMITTAL PACKAGE TRUST THE ORIGINAL. SUBMITTAL PACKAGE FlexHead Brochure We invented the concept of flexible fire protection The FlexHead Advantage FLEXHEAD QUALITY Best corrosion resistance Made from 100% 04 stainless

More information

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent

More information

FLEXIBLE CORRUGATED TUBE

FLEXIBLE CORRUGATED TUBE Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated

More information

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400 Page 1 of 8 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for

More information

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage Quick response concealed pendent sprinkler vk465 (K4.2) January 1, 2011 Sprinkler 64a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK465 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for

More information

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5 Bulletin 034 Rev. F Model G5 Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Product Features Model G5

More information

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. Page 1 of 6 1. DESCRIPTION Viking Quick Response Extra-Large Orifice Pendent Sprinkler VK377 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings

More information

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA Page 1 of 5 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design

More information

standard response/ quick response extended coverage

standard response/ quick response extended coverage 1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE June 1, 2007 1. DESCRIPTION Viking Quick Response Fusible Element Pendent Sprinklers VK330, VK332, VK353 and HP Sprinklers VK318 and VK343 are small, thermosensitive, solder link spray sprinklers available

More information

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Quick Response Dry Concealed Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. Page 1 of 6 Page 1 of 6 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet

More information

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 0786 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Model V34 standard spray sprinklers are designed to produce large discharge capacity in a hemispherical pattern standard in commercial applications. The

More information

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319) February 13, 2009 Sprinkler 43a 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various

More information

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j April 22, 2011 Sprinkler 11j 1. DESCRIPTION Viking Standard Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation

More information

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar). Page 1 of 6 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation on concealed

More information

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5 DOC Cremer Heating and Hot Water Plant Project Number: M 1411-04 TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION 21 30 00- WATER BASED FIRE PROTECTION SYSTEMS... 5 SECTION 22 40 00 -PLUMBING

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

December 14, 2015 Page 1 of 7 TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA December 14, 015 Page 1 of 7 1. DESCRIPTION Viking Standard Response/Quick Response Extended Coverage Dry Concealed Pendent s are thermosensitive spray sprinklers suitable for use in areas subject to freezing.

More information

Standard response. elo sprinklers

Standard response. elo sprinklers Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent

More information

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA March 14, 2008 Sprinkler 41a Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Pendent

More information

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202. 1. DESCRIPTION Viking Standard Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation with a domed cover that provides

More information

quick response horizontal sidewall sprinkler vk360 (K8.0)

quick response horizontal sidewall sprinkler vk360 (K8.0) February 26, 2010 Sprinkler 43o 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature

More information

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279) February 26, 2014 Sprinkler 106s 1. DESCRIPTION Viking Quick Response Ordinary Hazard Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing.

More information

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009 May 1, 2009 Sprinkler 41g 1. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation

More information

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK5 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7 Page 1 of 7 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK003 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA.   Cover Plate Assembly must be ordered separately: Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK0 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high

More information

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Page 1 of 5 Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK0 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0) Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers

More information

standard response large orifice dry

standard response large orifice dry February 26, 2014 Sprinkler 101o 1. DESCRIPTION Viking Standard Response Large Orifice Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6 Page 1 of 6 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK004 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK638 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings

More information

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data Page 1 of 5 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK638 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings

More information

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal

More information

DISCONTINUED PRODUCT. reference publication

DISCONTINUED PRODUCT. reference publication SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V39 ECLH concealed sprinkler is designed with a K8.0 orifice size to provide added coverage at normal light hazard operating pressures. The design

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

quick response sprinkler vk194 Sprinkler 104j January 1, 2011 January 1, 2011 Sprinkler 104j 1. DESCRIPTION Viking Quick Response Dry Concealed Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are

More information

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed. Page of 5. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK506 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor allows

More information

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler available in several different finishes and temperature

More information

Sprinkler Identification Numbers

Sprinkler Identification Numbers Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-50 Model Early Suppression Fast Response Pendent Sprinklers 16.8 K-factor General Description The Model Pendent Sprinklers (Ref. Figure 1) are Early

More information

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634) January 1, 2011 Sprinkler 92a 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation

More information

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler

More information

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0) Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler available in several different finishes and temperature

More information

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage Quick response concealed pendent sprinkler vk464 (K8.0) January 1, 2011 Sprinkler 55a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK464 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems

More information

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for

More information

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Page of 7 TECHNICAL DATA. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent VK6 and HP VK6 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe

More information

standard response elo upright and pendent sprinklers (storage-density/area)

standard response elo upright and pendent sprinklers (storage-density/area) December 5, 2008 Sprinkler 13e 1. DESCRIPTION The Viking Standard Response ELO Upright and Pendent Sprinklers are thermosensitive glass bulb spray sprinklers available in several different finishes and

More information

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Quick Response Extended Coverage Concealed Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler pre-assembled with a threaded adapter for installation

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3 Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard Response ELO Pendent Sprinkler is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings

More information

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet

More information

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319) February 3, 2014 Sprinkler 43a 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various

More information

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608 Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard/Quick Response Extended Coverage Light Hazard Extra- Large Orifice (ECLH-ELO/QRECLH-ELO) Pendent Sprinkler VK608 is a thermosensitive spray

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

STANDARD/quick. Sprinkler 42o. August 8, 2011

STANDARD/quick. Sprinkler 42o. August 8, 2011 August 8, 2011 Sprinkler 42o 1. DESCRIPTION Viking Standard/Quick Response Concealed Fusible Element Pendent Sprinkler VK353 is a thermosensitive solder link spray sprinkler pre-assembled with a threaded

More information

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area) Page of 4. DESCRIPTION The Viking Quick Response Extra-Large Orifice Upright Sprinkler VK5 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings

More information