Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

Size: px
Start display at page:

Download "Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85"

Transcription

1 Victaulic VicFlex Sprinkler Fittings Series H and H-CC Braided Flexible Hoses 0.8 Series H Series H-CC.0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,, 8, 0, "/90, 9, 9,, 80. Note: length includes adapter nipple and."/0 straight reducer. Series H-CC Braided Hose:,, 8, 0, "/90, 9, 9,, 80. Note: length includes captured coupling and."/0 straight reducer. Sprinkler educers: Sprinkler Connections: ½ and ¾"/ and 0 Straight Lengths:., 9, "/0, 0, 0 90º Elbows: Short (typically used with concealed sprinklers) Long (typically used with recessed pendent sprinklers) Low Profile Short (for use with Style B, B and B Bracket) Low Profile Long (for use with Style B, B and B Bracket) Inlet Connections: "/ Grooved IGS "/ NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFP standards. ¾"/0 NPT or BSPT adapter nipples available for VdS. ¼"/ BSPT adapter nipples available for LPCB. LWYS EFE TO NY NOTIFICTIONS T THE END OF THIS DOCUMENT EGDING PODUCT INSTLLTION, MINTENNCE O SUPPOT. System No. Location Spec Section Paragraph Submitted By Date pproved Date ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

2 .0 PODUCT DESCIPTION (Continued) Brackets: Style B for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place Style B for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style B for surface mount applications, wood, metal and block walls, or ceilings Style B for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style B for hard-lid ceilings, allows for vertical sprinkler adjustment Style B for suspended and hard-lid ceilings Style B djustable for suspended and hard-lid ceilings Style B8 for hard-lid ceilings with CD 0/ profile metal studs (regionally available) Style B9 for hard-lid ceilings with hat furring channel grid systems Style B0 for rmstrong TechZone ceilings Style B for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90 low profile elbows) Style B for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to "/. Maximum Working Temperature F/0 C Maximum Working Pressure 00 psi/ kpa (FM pproval) psi/0 kpa (culus Listed) kpa/ psi (VdS/LPCB pproved). MPa (CCCf pproved) Connections To adapter nipple (inlet) via "/. Grooved IGS "/. NPT or BSPT male thread ¾"/0 BSPT male thread (VdS only) ¼"/ BSPT male thread (LPCB only) To sprinkler head (outlet) via ½" or ¾"/ or 0 Bend adius "/8 (FM/CCCf pproval) "/ (culus Listed) "/. (VdS/LPCB pproved) Maximum llowable Sprinkler K-Factors FM (½"/ reducer) K./8, (S.I.), (¾"/0 reducer) K.0/0, (S.I.) culus (½"/ reducer) K8.0/, (S.I.), (¾"/0 reducer) K.0/0, (S.I.) VdS/LPCB (½"/ reducer) K./8, (S.I.), (¾"/0 reducer) K8.0/, (S.I.).0 CETIFICTION/LISTINGS ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

3 .0 SPECIFICTIONS MTEIL Series H Flexible Hose: 00-series Stainless Steel Collar/Weld Fitting: 00-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation ing: Nylon Nut and Nipple: Carbon Steel, Zinc Plated educer (½"/ or ¾"/0 ): Carbon Steel, Zinc-Plated Low Profile Elbows: Stainless Steel Brackets: Carbon Steel, Zinc-Plated Series H-CC Flexible Hose: 00-series Stainless Steel Collar/Weld Fitting: 00-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation ing: Nylon Coupling etainer ing: Polyethelene Nut and Nipple: Carbon Steel, Zinc Plated educer (½"/ or ¾"/0 ): Carbon Steel, Zinc-Plated Housing: Ductile iron conforming to STM, Grade --. Ductile iron conforming to STM 9, Grade --, is available upon special request. Coupling Housing Coating: Orange enamel (North merica, sia Pacific). ed enamel (Europe). Hot dipped galvanized. Gasket: Grade E EPDM (Type ) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and pproved by Factory Mutual esearch for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. eference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of STM 9 and physical requirements of STM 8. Linkage: CrMo lloy Steel zinc electroplated per STM B Zn/Fe, Type III Finish ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

4 .0 DIMENSIONS Product Details - Series H Braided Hose B 8 Item Description Flexible Hose Isolation ing Gasket Nut dapter Nipple Braid Collar/Weld Fitting 8 Sleeve Hose Length s Hose Length B /90./ /90 /9./9 /9 8/9./0 8/0 0/./8 0/ /80./8 /80 Series H-CC Braided Hose 8 Hose Length B /90./ 9.8/ /9 9./9.8/88 8/9./0.8/89 0/./9 8.8/9 /80./ 0.8/98 B Item Description Flexible Hose Isolation ing Gasket Nut Captured Coupling Braid Collar/Weld Fitting 8 Sleeve ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

5 .0 DIMENSIONS (Continued) Standard educer."/0 straight reducer Optional educers 9.0"/9 straight reducer.0"/0 straight reducer."/.."/..8"/.."/.9 Short 90 elbow reducer Long 90 elbow reducer The Short 90 elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. FM/VdS pproved only. Low Profile.8"/.9"/."/."/ Short 90 elbow reducer Long 90 elbow reducer Style B: When low profiles elbows are used with the Style B bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

6 . DIMENSIONS VicFlex Brackets Style B Suspended Ceilings Hard-Lid Ceilings (FM Only) Item Description "/0 or 8"/9 Square Bar Patented Center Bracket End Bracket Both sizes FM/VdS/LPCB pproved, culus listed Style B Suspended Ceilings Hard-Lid Ceilings Item Description "/0 or 8"/9 Square Bar Patented Vertically djustable Center Bracket End Bracket Both sizes FM/VdS/LPCB pproved, culus listed Style B Surface Mount pplications FM/LPCB pproved ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

7 . DIMENSIONS VicFlex Brackets Style B Hard-Lid Ceilings with Hat furring channel grid system Item Description "/0 or 8"/9 Square Bar Patented Vertically djustable Center Bracket End Bracket for Hat Furring Channel Both sizes FM/VdS/LPCB pproved, culus listed. Style B Hard-Lid Ceilings Item Description "/0 or 8"/9 Square Bar Patented Vertically djustable Center Bracket End Bracket Both sizes FM/VdS/LPCB pproved, culus listed. Style B Suspended Ceilings Hard-Lid Ceilings Item Description "/0 or 8"/9 Square Bar Patented -Bee Center Bracket End Bracket Both sizes FM/VdS/LPCB pproved. Style B djustable Suspended Ceilings Hard-Lid Ceilings Item Description 00 or Square Bar Patented -Bee Center Bracket End Bracket (adjustable) Both sizes FM/VdS/LPCB pproved ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

8 . DIMENSIONS VicFlex Brackets Style B8 Hard-Lid Ceilings Item Description 00 or Square Bar Patented Vertically djustable Center Bracket End Bracket Both sizes FM/VdS/LPCB pproved. Style B0 Suspended ceilings rmstrong TechZone Item Description "/ Square Bar Patented -Bee Center Bracket End Bracket FM/VdS/LPCB pproved, culus listed. Style B Suspended ceilings Hard-Lid ceilings Item Description "/0 or 8"/9 Square Bar Patented -Bee Center Bracket End Bracket FM/VdS pproved, culus listed. Style B Suspended ceilings Hard-Lid ceilings Item Description Style B Bracket Body # Square Drive Set Screw FM pproved ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 8

9 . DIMENSIONS CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Suspended Ceiling Grid with ecessed Sprinkler Suspended Ceiling Grid with Concealed Sprinkler See Chart Style B See Chart."/ Typical ceiling grid See note /8"/ Typical ceiling tile "/0 or 8"/9 on Center V0 ¾"/9 MX. ECESS V0 ¾"/9 Max. ecess."/ /8"/0 "/ V0 MX. EXTENSION."/ Typical ceiling grid See note Bracket ssembly Style B /8"/.9 Typical ceiling tile "/0 or 8"/9 on Center V80 ½"/. MM MX. ECESS V80 ½"/. Max. ecess."/ /"/8. /8"/0. V80 MX. EXTENSION Bend adius Bend adius Suspended Ceiling Grid with ecessed Sprinkler with 90 Elbow (Long) Suspended Ceiling Grid with Concealed Sprinkler with 90 Elbow (Short) See Chart Style B."/ /8"/0 "/ See Chart Bracket ssembly Style B."/ /"/8 /8"/0."/ Typical ceiling grid /8"/ Typical ceiling tile."/ Typical ceiling grid /8"/ Typical ceiling tile See note "/0 or 8"/9 on Center V0 ¾" /9 MX. ECESS V0 ¾"/9 Max. ecess V0 MX. EXTENSION See note "/0 or 8"/9 on Center V80 ½"/. MX. ECESS V80 ½"/. Max. ecess V80 MX. EXTENSION Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 9

10 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with ecessed Sprinkler " " Stud #0 Screw Style B.8"/ ¾"/8 8"/9 " " Stud."/ 89 #0 Screw Style B.8"/ 8"/0 "/."/ 89 "/0 Stud C/C V80 ½"/ MX. ECESS V80 ½"/. Max. ecess V80 MX. EXTENSION "/0 Stud C/C V0 ¾"/9 MX. ECESS V0 ¾"/9 Max. ecess V0 MX. EXTENSION Bend adius Bend adius Hard-lid Ceiling Grid with ecessed Sprinkler with 90 Elbow (Short) Hard-lid Ceiling with Concealed Sprinkler with 90 Elbow (Long) " " Stud."/ 89 #0 Screw Style B.8"/ 8"/0 "/ " " Stud #0 Screw Style B.8"/ ¾"/8 8"/9."/ 89 "/0 Stud C/C "/0 Stud C/C V80 ½"/ MX. ECESS V80 MX. EXTENSION V80 ½"/. Max. ecess V0 ¾"/9 Max. ecess.0 Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 0

11 . DIMENSIONS CLENCES WITHIN SIDEWLL Series H Braided Hose and Style B Bracket Horizontal Sidewall Sprinkler Horizontal Sidewall Sprinkler with 90 Elbow (Long) " " Stud."/ 89 #0 Screw Style B.8"/ 8"/0 "/ " " Stud."/ 89 #0 Screw Style B.8"/ 8"/0 "/ "/0 Stud C/C "/0 Stud C/C V09 ¾"/9 MX. ECESS V09 MX. EXTENSION V0 ¾"/9 Max. ecess V0 ¾"/9 Max. ecess Bend adius Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

12 . DIMENSIONS CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Hat Furring Channel Grid with ecessed Sprinkler See Chart /8"/0 "/ See note Typical "/0 "/0 on Center /8"/.9 Typical ceiling tile /8"/ Typical ceiling grid V0 ¾"/9 Max. ecess Bend adius Hat Furring Channel Grid with ecessed Sprinkler with 90 Elbow (Long) Hat Furring Channel Grid with Concealed Sprinkler with 90 Elbow (Short) See Chart See Chart /8"/0 "/ /8"/0 "/ /8"/ Typical ceiling tile /8"/ Typical ceiling tile See note Typical "/0 "/0 on Center /8"/ Typical ceiling grid See Note "/0 "/0 on Center V80 ½"/. MX. ECESS /8"/ Typical ceiling grid V80 MX. EXTENSION V0 ¾"/9 Max. ecess V0 ¾"/9 Max. ecess Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

13 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Hard-lid Ceiling with ecessed Sprinkler."/ 89 #0 Screw Style B."/ 8"/0 "/."/ 89 #0 Screw Style B."/ ¾"/8 8"/9 " " Stud " " Stud "/0 Stud C/C /8"/ Typ. Drywall V0 ¾"/9 Max. ecess /8"/ Typ. Drywall "/0 Stud C/C V80 ½"/ MX. ECESS V80 ½"/ Max. ecess V80 MX. EXTENSION Bend adius Bend adius ecessed Pendent with 90 Elbow (Long) Hard-lid Ceiling with Concealed Pendent with 90 Elbow (Short)."/ 89 #0 Screw Style B."/ 8"/0 "/ #0 Screw Style B."/ "/8 8"/9 " " Stud /8"/ Typ. Drywall."/ 89 " " Stud /8"/ Typ. Drywall "/0 Stud C/C "/0 Stud C/C V0 ¾"/9 MX. ECESS V0 ¾"/9 Max. ecess V0 MX. EXTENSION V80 ½"/ MX. ECESS V80 ½"/ Max. ecess V80 MX. EXTENSION Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

14 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket (LOW POFILE SOLUTION) Suspended Ceiling Grid with ecessed Sprinkler with LP 90 Elbow (Long) Style B "/ 8"/0 "/."/ Typical ceiling grid /8"/ Typical ceiling tile See Note "/0 or 8"/9 on Center V0 ¾"/9 MX. ECESS V0 MX. EXTENSION.0 Suspended Ceiling Grid with Concealed Pendent with LP 90 Elbow (Short) Style B "/ "/8 8"/0."/ Typical ceiling grid /8"/ Typical ceiling tile See Note "/0 or 8"/0 on Center V80 ½"/ MX. ECESS Ceiling Face V80 MX. EXTENSION.9 99 Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

15 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Suspended Ceiling Grid with ecessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with ecessed Sprinkler and Straight."/0 educer 8 inch/ 9 Unfinished Ceiling Face /8-inch/M0 Threaded od (-foot/0.9-meter Maximum Length) /8-inch/M0 Threaded od (-foot/0.9-meter Maximum Length) 8 inch/ 9 Unfinished Ceiling Face 8 inch/ "" See Table 8 inch/ "" See Table "B" See Table "B" See Table Face of /8-inch/- Typical Ceiling Face of /8-inch/- Typical Ceiling V0 ½"/. MX. ECESS V0 ¾"/9 MX. ECESS Low Profile Short Elbow Low Profile Long Elbow Standard Short Elbow Standard Long Elbow Standard Straight educer ¾"/9 ecessed* Concealed ¾"/9 ecessed Concealed ¾"/9 ecessed Concealed ¾"/9 ecessed Concealed ¾"/ 9 ecessed Concealed equired Installation Space B Distance from Top of Typical Ceiling Tile to Bottom of Gate * djustability will be limited Sprinkler location relative to /8" threaded rod is /8"/9 center-to-center. Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

16 . DIMENSIONS (Continued) CLENCES BOVE CEILING Series H Braided Hose and Style B Bracket Surface Mount pplication with ecessed Sprinkler C ¾"/ 9. See Note B /8"/0 "/ Wall Thickness "" 0 0 Hose Clearances Outlet Length "B" Hose Clearance "C" Bend adius "" 8 00 Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. See installation instructions for mounting screw type and size ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

17 . DIMENSIONS BNCHLINE CLENCES Series H Braided Hose with female threaded outlet Series H-CC Braided Hose with grooved outlet Female Threaded Weld Outlet No. Grooved Weld Outlet "/0 "/0 Bend adius Bend adius ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

18 . DIMENSIONS (Continued) BNCHLINE CLENCES Series H Braided Hose with Style 9 threaded outlet Series H-CC Braided Hose with Style 9 grooved outlet Style 9 Threaded Mechanical Tee Outlet Style 9 Grooved Mechanical Tee Outlet "/0 "/0 Bend adius Bend adius ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 8

19 .0 PEFOMNCE FICTION LOSS DT Series H and H-CC Braided Hoses with Straight."/0 educers Style B, B, B, B and B0 Brackets Equivalent Length of "/. Sch. 0 Pipe (C=0) Maximum Number of 90 Bends at "/ Bend adius / //type feet/meters / ½"//Straight /.9 ¾"/0/Straight /. /900 ½"//Straight /. ¾"/0/Straight /.0 8/ ½"//Straight /9.8 8 ¾"/0/Straight /. 8 0/ ½"//Straight /.0 0 ¾"/0/Straight /.0 0 /800 ½"//Straight /.8 ¾"/0/Straight /. Series H and H-CC Braided Hose with 90 Low Profile Elbows Style B VicFlex Bracket Equivalent Length of "/. Sch. 0 Pipe Maximum Number of 90 Bends at "/ Bend adius / / feet/meters / ½"/ /. ¾"/0 /. /900 ½"/ /.9 ¾"/0 8/8. 8/ ½"/ /. 8 ¾"/0 /.8 8 0/ ½"/ 9/.9 0 ¾"/0 0/. 0 /800 ½"/ /9.8 ¾"/0 / ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 9

20 .0 PEFOMNCE FICTION LOSS DT (Continued) Series H and H-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at "/ center line bend radius Length of Stainless Steel Flexible Hose Outlet Size Bend Bends Bends Bends Bends Bends Bends 8 Bends 9 Bends 0 Bends Bends Bends / / feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters / ½"/ 8./..0/..0/.0.0/.9 N. N. N. N. N. N. N. N. ¾"/0 0.0/.0./.8.0/..0/. N. N. N. N. N. N. N. N. /900 ½"/./..0/.9 8.0/. 9.0/.8.0/. N. N. N. N. N. N. N. ¾"/0.0/..0/. 9./.9 0.0/..0/.0 N. N. N. N. N. N. N. 8/ ½"/./..0/. 9./.9 0.0/..0/..0/. 8.0/8..0/9.8 N. N. N. N. ¾"/0.0/. 9.0/.8./../..0/.9.0/8. 0.0/9..0/. N. N. N. N. 0/ ½"/./..0/..0/8. 8./8. 0.0/9..0/9..0/..0/.8.0/..0/.0 N. N. ¾"/0.0/.0.0/. 8.0/8. 9./9.0 0./9..0/9. 8.0/..0/.8.0/..0/.0 N. N. /800 ½"/ 0.0/9..0/9.8./../. 0./..0/.8.0/.8.0/.0 9.0/.9.0/.8.0/..0/.8 ¾"/0.0/9.8./9.9.0/0../ /. 0./..0/..0/.0 0.0/..0/..0/.8.0/. S: Values for use with."/0 straight reducers. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system ev B Updated 08/0 0 Victaulic Company. ll rights reserved. 0

21 . PEFOMNCE FICTION LOSS DT Series H and H-CC Braided Hoses Style B, B, B, B, B, B, B dj., B8, B0 and B VicFlex Brackets Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of "/. Sch. 0 Pipe Maximum Number of 90 Bends at "/8 Bend adius FM S: / Imperial/S.I. //type feet/meters /./8. ½"//Straight./. ½"//90 Elbow./. /900./8. ½"//Straight.8/8. ½"//90 Elbow./.8 8/./8. ½"//Straight 8./. ½"//90 Elbow 0./9. 0/./8. ½"//Straight./.9 ½"//90 Elbow.9/0.9 /800./8. ½"//Straight./. ½"//90 Elbow./. / 8.0/. ¾"/0/Straight.8/. ¾"/0/90 Elbow.8/. / /. ¾"/0/Straight 0/.0 ¾"/0/90 Elbow 9./.0 8/ 8.0/. ¾"/0/Straight.8/8. ¾"/0/90 Elbow./8. 0/ 8.0/. ¾"/0/Straight./0.9 ¾"/0/90 Elbow./0. / /. ¾"/0/Straight./. ¾"/0/90 Elbow 0./. /./. ¾"/0/Straight./.0 ¾"/0/90 Elbow.8/. /900./. ¾"/0/Straight 9./.9 ¾"/0/90 Elbow 0./. 8/./. ¾"/0/Straight./8. ¾"/0/90 Elbow.9/8. 0/./. ¾"/0/Straight.9/0. ¾"/0/90 Elbow /0. /800./. ¾"/0/Straight./. ¾"/0/90 Elbow./.8 /.0/0. ¾"/0/Straight.9/. ¾"/0/90 Elbow./. /900.0/0. ¾"/0/Straight 9./.9 ¾"/0/90 Elbow 9./.9 8/.0/0. ¾"/0/Straight 0./9. ¾"/0/90 Elbow 9./8.9 0/.0/0. ¾"/0/Straight.9/0. ¾"/0/90 Elbow./0. /800.0/0. ¾"/0/Straight./. ¾"/0/90 Elbow 8./. Series H has been tested and pproved by FM Global for use in wet, dry and preaction systems per NFP,, and D and FM data sheets -0, -, and -8. FM and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. Differences in equivalent lengths are due to varying test methods, per FM and VdS standards. efer to these standards for additional information regarding friction loss test methods. EXMPLE: 8-inch hose installed with two 0 bends and two 90 bends at a -inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 0, which is less than the allowable ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

22 . PEFOMNCE FICTION LOSS DT Series H Braided Hose with 90 Low Profile Elbows Style B, B and B VicFlex Bracket Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of "/. Sch. 0 Pipe Maximum Number of 90 Bends at "/8 Bend adius FM S: / Imperial/S.I. / feet/meters /./8. ½"/./. /900./8. ½"/.0/. 8/./8. ½"/.0/. 0/./8. ½"/.0/0. /800./8. ½"/./. / 8.0/. ¾"/0./. / /. ¾"/0.9/. 8/ 8.0/. ¾"/0.8/8. 0/ 8.0/. ¾"/0./9.9 / /. ¾"/0 0./. /./. ¾"/0./. /900./. ¾"/0.0/. 8/./. ¾"/0.9/. 0/./. ¾"/0.9/0.0 /800./. ¾"/0 0.9/. /.0/0. ¾"/0./. /900.0/0. ¾"/0.8/. 8/.0/0. ¾"/0./. 0/.0/0. ¾"/0./9.9 /800.0/0. ¾"/0 0./. Series H has been tested and pproved by FM Global for use in wet, dry and preaction systems per NFP,, and D and FM data sheets -0, -, and -8. FM and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. Differences in equivalent lengths are due to varying test methods, per FM and VdS standards. efer to these standards for additional information regarding friction loss test methods. EXMPLE: 8-inch hose installed with two 0 bends and two 90 bends at a -inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 0, which is less than the allowable ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

23 . PEFOMNCE FICTION LOSS DT Series H and H-CC Braided Hose Style B, B, B, B, B, B dj., B8, B0 and B Brackets Series H Hose Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 0 DN (, x,) Maximum Number of 90º Bends at "/. Bend adius / / meters/feet meters/feet / /½" 0 /¾"./ / /½" 0 /¾"./.0 /8 /½" 0 /¾" 8./.9 /0 /½" 0 /¾" 0./. 800/ /½" 0 /¾".8/.0 VDS CEILING MNUFCTUES LIST B, B, B, B0,B B B, B8. MF. rmstrong. Chicago Metallic. Dipling. Durlum. Geipel. Gema-rmstrong 8. Hilti 9. Knauf 0. Lafarge. Linder. Odenwald. ichter. igips. ockfon Pagos. Suckow & Fischer. USG Donn No specific approval. Hilti. Knauf. Lafarge. Lindner. igips Series H Braided Hose Style B, B, B, B, B, B, B8, and B0 Brackets Series H Braided Hose Style B, B, B, B, B, B, B8, B0 and B Brackets Series H Hose Series H Braided Hose Length of Stainless Steel Flexible Hose Outlet Size Equivalent Length of steel pipe according to EN 0 DN (, x,) Maximum Number of 90º Bends at "/. Bend adius Length of Stainless Steel Flexible Hose Equivalent Length of "/. Sch. 0 Pipe / //type meters/feet / /½"/Straight 0 /¾"/Straight.8/.0 900/ /½"/Straight 0 /¾"/Straight./.9 /8 /½"/Straight 0 /¾"/Straight./.0 /0 /½"/Straight 0 /¾"/Straight./. 800/ /½"/Straight 0 /¾"/Straight./8. / meters feet 90/ /.00. 0/8.. / / ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

24 .0 NOTIFICTIONS WNING It is the responsibility of the system designer to verify suitability of 00-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on 00-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. The VicFlex Series H Hose has been tested and evaluated by Spears for acceptable use with Spears CPVC Products and is therefore covered under the Spears FlameGaurd Installer Protection Plan..0 EFEENCE MTEILS CHCTEISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends X bend radius X bend radius bend radius bend radius O O 90 bend radius bend radius bend radius bend radius bend radius For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-B-B-B0 I-VicFlex-B I-VicFlex-B I-VicFlex-B8 I-VicFlex-B-B9 I-VicFlex-B User esponsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recoendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property ights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recoendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms Patented or Patent Pending refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. ll products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation eference should always be made to I-VICFLEX-B-B-B0, I-VICFLEX-B-B9, I-VICFLEX-B, or I-VICFLEX-B8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at Warranty efer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries ev B Updated 08/0 0 Victaulic Company. ll rights reserved.

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85 Victaulic Vic-Flex Sprinkler Fittings Series H Braided Flexible Hose 0..0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,,, 0, "/0,, 0,, 0. Note: length includes adapter nipple and."/0

More information

10.85 VicFlex Sprinkler Fittings

10.85 VicFlex Sprinkler Fittings Series AQB Braided Flexible Hose Assemblies VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing

More information

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic

More information

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Style Sprinkler Fittings for Surface Mount Applications INTRODUCTION WARNING Read and understand all instructions before attempting to install any

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6 INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Sprinkler Fittings: Style Bracket Assembly with Models V33,, or V40 Dry Sprinklers Read and understand all instructions before attempting to install

More information

Discontinued Product

Discontinued Product SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve

More information

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop

More information

Series 759 FireLock Alarm Check Valve

Series 759 FireLock Alarm Check Valve R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.70 Series 759 FireLock Alarm Check Valve Grooved Grooved PRODUCT DESCRIPTION U L FM U L C See Victaulic publication 10.01 for details. The Victaulic

More information

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date MEA: 276-99-E CSFM: 7770-0531:113 The Series 766 high pressure butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has been developed for fire pump metering

More information

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA Page 1 of 7 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems

More information

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 211313 WET-PIPE SPRINKLER SYSTEMS PRT 1 GENERL 1.01 RELTED DOCUMENTS. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

quick response Sprinkler 105a October 25, 2010

quick response Sprinkler 105a October 25, 2010 October 25, 2010 Sprinkler 105a 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

VicFlex TM Stainless Steel Sprinkler Fittings

VicFlex TM Stainless Steel Sprinkler Fittings V i c t a u l i c f i r e p r o t e c t i o n s y s t e m s Fast, dependable installation up to 10x faster than rigid pipe Durable performance Cost-effective maintenance and retrofit VicFlex TM Stainless

More information

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall L C The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response This concealed, designer style sprinkler allows up to 1/2"/13 mm adjustment to accommodate concealment needs. The standard design provides a consistent hemispherical spray pattern. The separate two-piece

More information

Model F3 Dry Sprinklers

Model F3 Dry Sprinklers Features 1. The Model F3 utilizes Belleville Spring Closure Technology 2. Styles available for Model F3 Dry s: Pendent Recessed Pendent Concealed Horizontal Sidewall Recessed Horizontal Sidewall 3. 1½"

More information

FLUSH HORIZONTAL SIDEWALL

FLUSH HORIZONTAL SIDEWALL The V36 dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model V36

More information

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5 DOC Cremer Heating and Hot Water Plant Project Number: M 1411-04 TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION 21 30 00- WATER BASED FIRE PROTECTION SYSTEMS... 5 SECTION 22 40 00 -PLUMBING

More information

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for

More information

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent Pendent, Level Pendent & Pendent The Model V36 Series Dry Type Pendent and Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for

More information

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL FLSH The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Models V3608 and

More information

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL V3606 QICK RESPONSE The Model V36 Series Dry Type Pendent and Recessed Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special applications

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers February 24, 2012 Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage Quick response concealed pendent sprinkler vk465 (K4.2) January 1, 2011 Sprinkler 64a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK465 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems

More information

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available

More information

FLEXIBLE CORRUGATED TUBE

FLEXIBLE CORRUGATED TUBE Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated

More information

2. Welding Materials and Procedures shall conform to the ASME Code.

2. Welding Materials and Procedures shall conform to the ASME Code. PART 1 GENERAL 1.01 Scope of Standard A. The design guidelines contained herein include the requirements for systems, materials, fittings and valves utilized for fire protection systems at Sam Houston

More information

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA March 14, 2008 Sprinkler 41a Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Pendent

More information

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending FireLock LP-46 Low Pressure Storage Sprinkler This storage sprinkler was designed for controlling fires in single, double and multiple row rack storage of up to Cartoned, Unexpanded, Group A plastic commodities

More information

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Quick Response Dry Concealed Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK5 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon

More information

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

TRUST THE ORIGINAL. SUBMITTAL PACKAGE TRUST THE ORIGINAL. SUBMITTAL PACKAGE FlexHead Brochure We invented the concept of flexible fire protection The FlexHead Advantage FLEXHEAD QUALITY Best corrosion resistance Made from 100% 04 stainless

More information

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet

More information

microfast quick response Pendent sprinkler VK302 (K5.6)

microfast quick response Pendent sprinkler VK302 (K5.6) Page 1 of 6 1. DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet

More information

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400 Page 1 of 8 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions

More information

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking dry vertical sidewall sprinklers are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems,

More information

December 14, 2015 Page 1 of 7 TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA December 14, 015 Page 1 of 7 1. DESCRIPTION Viking Standard Response/Quick Response Extended Coverage Dry Concealed Pendent s are thermosensitive spray sprinklers suitable for use in areas subject to freezing.

More information

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS * * See page 2 for FM Approved product configurations SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 ECLH sprinklers are designed with a K14.0 orifice size to provide added coverage at normal

More information

standard response/ quick response extended coverage

standard response/ quick response extended coverage 1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6 Page 1 of 6 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK004 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8 City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a. September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction

More information

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The V3806 concealed, designer style sprinkler allows up to 1/4"/8 mm adjustment to accommodate concealment needs. The separate two-piece mounting cup/cover plate

More information

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction

More information

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j April 22, 2011 Sprinkler 11j 1. DESCRIPTION Viking Standard Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation

More information

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar). Page 1 of 6 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation on concealed

More information

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

quick response sprinkler vk194 Sprinkler 104j January 1, 2011 January 1, 2011 Sprinkler 104j 1. DESCRIPTION Viking Quick Response Dry Concealed Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high

More information

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202. 1. DESCRIPTION Viking Standard Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation with a domed cover that provides

More information

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for

More information

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA Page of 7 TECHNICAL DATA. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent VK6 and HP VK6 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe

More information

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

standard response large orifice dry

standard response large orifice dry February 26, 2014 Sprinkler 101o 1. DESCRIPTION Viking Standard Response Large Orifice Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers

More information

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V3426 residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 6.9 K-Factor will aid

More information

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7 Page 1 of 7 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK003 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 5.6 K-Factor will aid in the system

More information

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279) February 26, 2014 Sprinkler 106s 1. DESCRIPTION Viking Quick Response Ordinary Hazard Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing.

More information

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

DISCONTINUED PRODUCT

DISCONTINUED PRODUCT SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V27 residential sprinklers are designed to meet the requirements of NFPA 13, 13D and 13R for residential use in a variety of room sizes, depending

More information

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009 May 1, 2009 Sprinkler 41g 1. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation

More information

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA.   Cover Plate Assembly must be ordered separately: Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK0 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Page 1 of 5 Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK0 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.

More information

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5 Bulletin 034 Rev. F Model G5 Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Product Features Model G5

More information

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. Page 1 of 6 Page 1 of 6 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler available in several different finishes and temperature

More information

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0) Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler available in several different finishes and temperature

More information

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to

More information

quick response horizontal sidewall sprinkler vk360 (K8.0)

quick response horizontal sidewall sprinkler vk360 (K8.0) February 26, 2010 Sprinkler 43o 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature

More information

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319) February 13, 2009 Sprinkler 43a 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

micromatic Standard response Horizontal Sidewall sprinkler

micromatic Standard response Horizontal Sidewall sprinkler Page 1 of 7 1. DESCRIPTION The Micromatic Viking Standard Response Horizontal Sidewall Sprinkler VK104 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature

More information

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA Page 1 of 7 1. DESCRIPTION The Viking Attic Upright VK696 is a specific application concealed space sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces

More information

All electrical systems and components require CSA approval stamped on the nameplate of the heater.

All electrical systems and components require CSA approval stamped on the nameplate of the heater. /20.0 PURPOSE This specification describes the minimum requirements for design, material of construction, and installation requirements for Automatic Sprinkler Systems for all plants at Vale Operations

More information

esfr dry pendent sprinkler Vk501 (k14.0)

esfr dry pendent sprinkler Vk501 (k14.0) September 13, 2012 Sprinkler 122a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK501 is a fast response fusible element type sprinkler designed for use in storage

More information

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634) January 1, 2011 Sprinkler 92a 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal

More information

STANDARD/quick. Sprinkler 42o. August 8, 2011

STANDARD/quick. Sprinkler 42o. August 8, 2011 August 8, 2011 Sprinkler 42o 1. DESCRIPTION Viking Standard/Quick Response Concealed Fusible Element Pendent Sprinkler VK353 is a thermosensitive solder link spray sprinkler pre-assembled with a threaded

More information

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage Quick response concealed pendent sprinkler vk464 (K8.0) January 1, 2011 Sprinkler 55a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK464 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems

More information

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 7 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK102 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature

More information

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent

More information

SECTION AUTOMATIC SPRINKLER PIPING

SECTION AUTOMATIC SPRINKLER PIPING SECTION 15330 AUTOMATIC SPRINKLER PIPING ****** ***** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: This section contains several types of automatic sprinkler piping. Some piping is allowed

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

ADDITIONAL PRODUCTS 65

ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS Pictorial Table of Contents Model FastFlex Flexible Sprinkler Hose Page 67 Sprinkler & Valves Product Overview Page 72 Model UFBX Flexible Hoses Pages 68-69 Figure

More information

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA Page 1 of 7 1. DESCRIPTION The Micromatic Viking Standard Response Horizontal Sidewall Sprinkler VK104 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE June 1, 2007 1. DESCRIPTION Viking Quick Response Fusible Element Pendent Sprinklers VK330, VK332, VK353 and HP Sprinklers VK318 and VK343 are small, thermosensitive, solder link spray sprinklers available

More information

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS These Model V34 standard spray sprinklers are designed to produce large discharge capacity in a hemispherical pattern standard in commercial applications.

More information