1 MBM-100 Oscillating mill operating manual 3, Hagavish st. Israel Tel: , Fax: mrc@mrclab.com MRC.10.17
2 1. Operating instructions Warning Repair Safety Safety instruction Safety rules...3 Safety rules...4 Safety rules 5 3. Technical parameters Grinding jars Filling quantity Filling size Minimum size Power supply Driving power Safety protection Dimension Weight Floor space Transport Packing Transport Temperature variation Intermediate storage Supply schedule Installation Placed Remove safety screws Ambient temperature Humidity Altitude Electrical connection Ground protection Operation Operation elements Function table Display unit Power connection Grinding operation Clamp/Release jars Setting time Setting speed Storing grinding parameters Interrupt mode and time Start MBM Stop MBM Replace fuse Working instruction General Grinding operation Safety instruction for handing liquid nitrogen Cleaning Cleaning grinding jars Maintenance Wear Repair Checks Copyright Alteration
3 1. Operating instructions These operating instructions for the oscillating mill, Type MBM-100, give all the necessary information on the areas mentioned in the contents. They instruct the target groups for each of the defined areas, in order to ensure safe handling of the MBM-100 when used for the intended purpose. Knowledge of the relevant section is an essential Precondition for safe, proper use of the machine. This technical documentation is a reference work and also a set of teaching instructions. The Individual sections are complete in themselves. These operating instructions do not include Instructions for repairs. In case of possible defects or necessary repairs please contact your suppliers or MRC direct. 1.1 Warning Warnings are given by the following signs:: Injury to persons Damage to equipment Observe instructions for use 1.2 Repair These operating instructions do not include any repair instructions. For your own safety repairs must be carried out only by MRC or an authorize agent. 2. Safety 2.1 Safety instruction As the operating authority, it is your duty to ensure that all persons working on the MBM-100: Have read and understood all the instructions on safety, Before beginning work know all the instructions and regulations for the target group relevant to their work, Have access to the technical documentation for this 2
4 machine at all times, without problems. New personnel should be familiarized with safe, proper handling of the machine before beginning work on the MBM-100, either by verbal instruction from a competent person or through this technical documentation. Improper operation can cause injury to persons or damage to the equipment. You are responsible for your own safety and that of your employees. Ensure that no unauthorized persons have access to the MBM-100. For your own protection have your employees confirm that they have been instructed in operation of the MBM-100. We exclude any claims for damages of any kind for injury to persons and damage to equipment arising from non-observance of the following safety instructions 2.2 Safety rules Operation We exclude any liability for claims for damages in any form whatsoever for injury to persons or damage to the machine caused through non-observance of the following safety instructions Used Do not make any alterations to the machine and use only spare parts and accessories approved by MRC This will damage to equipment Furthermore, this will lead to the loss of any guarantee claims. Packing Please keep the packing material for the duration of the guarantee period, since, in case of a complaint and return of the machine in unsuitable packing material your guarantee claim will be at risk. Transport The MBM-100 must not be jolted, shaken or thrown during transport. Otherwise the electronic and mechanical components may be damaged. Temperature variations If subjected to high temperature variations the MBM-100 must be protected against condensed water. Otherwise the electronic components may be damaged. 3
5 Supply schedule If the delivery is incomplete or transport damage is found, you must inform the transporter and MRC immediately (within 24 hrs). Later complaints may possibly be no longer considered. Ambient temperature If the temperature drops below or exceeds the ambient temperature the electronic and Mechanical components may be damaged; the performance data are then altered to an unknown extent. Humidity At high atmospheric humidity the electronic and mechanical components may be damaged and the performance data are altered to an unknown extent. Electrical connection If the values on the rating plate are not observed the electrical and mechanical components may be damaged. Safety switch Don t open the lid of MBM-100, when MBM-100 is running, Injury to persons or damage to the machine. Check before start Ensure that the grinding jars are inserted correctly in the grinding jar holder Otherwise they can become damaged when starting the machine. Both milling positions must always be used since otherwise this will cause considerable unbalance Filling jars If filling the samples too much or too little, will influence the milling result. To little samples will damage the grinding jars and balls Safety instructions for handling liquid nitrogen Always wear protective goggles and protective gloves when handling liquid nitrogen. Liquid nitrogen has a temperature of 196 C and can cause frostbite or injury similar to burns if it comes into contact with the skin or eyes Only the stainless steel jars can be used with liquid nitrogen. GRINDER Follow the safety regulations of the cooling liquid supplier. GRINDER GRINDER accepts 对由于冷冻液体所造成的冻伤或者灼伤不负任何责任 no liability whatsoever arising from the use of liquid nitrogen or similar materials. 4
6 Cleaning Do not clean the MBM-100 under running water. Danger to life through current surge. Use only a cloth moistened with water. Cleaning agents and solvents should not be used not for cleaning the milling tools either Storage Components and the machine should be placed in the dry ventilated place. Repair These operating instructions do not include repair instructions. For your own safety repairs must be carried out only by MRC or an authorize agent 5
7 3.Technical data The MBM-100 is a laboratory machine and is suitable for milling and homogenizing soft, fibrous, hard and brittle materials in the wet and dry state. The MBM-100 have two grinding platform, grinding jars which have different materials and volume can be used. For fast, super fine milling of two samples simultaneously. The closed milling system guarantees complete recovery of the samples. Owing to the extremely short milling time and the high final fineness of the material to be milled The MBM-100 is also ideally suitable for sample preparation for all spectral analyses. Final finenesses of down to 10 µm can be achieved, depending on the milling time and the specific properties of the sample material. The optimum grinding jars filling is as a rule :1/3 of the grinding jar volume. If used the adapter, it can grinding 20~196 samples at the same time(it depends on the kinds of the adapter) Due to grinding with very short time and superfine grinding fineness, MBM-100 is the ideal choice for grinding the all sample preparation and analysis. Finally the sample size up to 10 um, this depending on the milling time and the nature of the sample material properties. Do not make any alterations to the machine and use only spare parts and accessories approved by MRC This will damage to equipment Furthermore, this will also lead to the loss of any guarantee claims. 3.1Grinding jars Material Stainless steel:5, 10, 25, 35, 50ml Zirconium oxide:35ml Tungsten carbide:25ml 3.2 Filling quantity 1/3~1/2grinding jar capacity 6
8 3.3 Maximum particle size of filling < 8mm, according to the material properties and different grinding jar capacity. 3.4 Minimum sample size About 10um,,according to the material properties. 3.5 Power supply 220VAC, 50Hz, 4.5A 3.6 Driving power 200W 3.7 Safety protection MBM-100 is equipped with a safety switch, when open the lid, the instrument can t be started. When the lid is closed The MBM-100 can be start. When the lid is opened during operation, MBM-100 will be automatic stopped. 3.8 Dimension mm(W D H) 3.9 Weight Net weight app: 34kg 3.10 Floor space mm In the back of the MBM-100 should have at least 10mm for ventilation. 4. Transport 4.1 Packing Packing is adapted to the transport route and conforms to generally applicable packaging guidelines Please keep the packing material for the duration of the guarantee period since if there is a complaint and the machine is returned with inadequate packing, your guarantee claim will be at risk. 4.2 Transport Net weigh:app 34kg The MBM-100 must not be knocked, shaken or thrown during transport. Otherwise the electronic and mechanical components can become damaged. 7
9 4.3 Temperature variation If temperature variations are high (e.g. during air transport) the MBM-100 must be protected against condensed water. Otherwise the electronic components can become damaged. 4.4 Intermediate storage Ensure that the MBM-100 is also stored dry during intermediate storage. 4.5 Supply schedule MBM-100: 1 Power supply cable: 1 Operating manual: 1 Fuse: 2 Check completeness of the delivery, including individually ordered accessories. Check perfect function ability of the MBM-100. If the delivery is incomplete or there is transport damage you must inform the transporter and MRC immediately (Within 24 hour). Later complaints may possibly be no longer considered. 5. Installation 5.1 Placed Mount the MBM-100 on a firm, stable laboratory bench since otherwise vibrations can be transmitted Net weight app: 34kg 5.2 Remove the safety screws Three transport safety screws which is located on the underside of the MBM-100. (marked with the arrow) Unscrew the safety screws and remove. Keep the transport safety screws for transport 8
10 5.3 Ambient temperature 5 to 40 If the ambient temperature drops below or exceeds these values the electronic and mechanical components can become damaged and performance data are changed to an unknown extent 5.4 Humidity Maximum relative humidity 80% at temperatures up to 31 C At higher atmospheric humidity the electronic and mechanical components can become damaged and performance data are changed to an unknown extent. 5.5 Altitude Max m (Above sea level). 5.6 Electrical connection The voltage and frequency for the MBM-100 are given on the type plate. Ensure that these values correspond to the available power supply system. Connect the MBM-100 to the power supply system using the supplied connection cable. Protection by external fusing is to be used when connecting the mains cable to the power supply, according to the regulations at the place of installation. 5.7 Ground protection When connection the power supply, must have the PE protective wire Don t obey the rules will result in personal injury. 9
11 6. Operation 6.1 Operation elements A B C D E F G H B C 10
12 E D I H H1 F H2 H3 6.2 Function table Elements Description Function A Lid Closed the chamber B Windows Observe the chamber Time pre-selection, speed pre-selection, C Control panel Milling mode pre-selection Programmed and starting / stopping the machine D Jars holder Hold the jars E Locking device Prevent jars to loosen F Hand wheel Tighten jars G Fan ventilation cooling H1 Power socket Connect power H2 Fuse holder 2 fuses in it H3 switch For switching MBM-100 to on and off I Grinding jar Milling sample 11
13 6.3 Display unit Function table SN. Description Function 1 Memory, operating mode The various operating modes, such as ON, program are displayed here. 2 Time display 00~99(min):00~59(sec) 3 Speed display 500~2000 rpm 4 Mode LED No lights :continuous mode;lights:interrupt mode 5 Pause LED Lights:pause 6 Time display 00~99(min):00~59(sec) (For Interrupt mode) 7 Power LED Red :lights when switch ON 8 Lid LED Lights: lid open, no lights :lid closed 9 Programmed key Selecting program from :P1~P9 10 Set key Set and save program 11 Time key Increases time 12 Time key Decrease time 13 Speed key Increase speed 14 Speed key Decrease speed 15 No press:continuous mode; Mode key Press once: Interrupt mode(4 LED lights) 16 Interrupt key (Interrupt mode) No press: :4 LED lights,use 17/18 key to set the grinding time Press once: 5 LED lights, use 17/18 key to set the pause time 17 Time key Increases interrupt milling time and pause time (Interrupt mode) 18 Time key Decrease interrupt milling time and pause time (Interrupt mode) 19 START key Start MBM STOP key Stop MBM
14 H1 6.4 Power connection Confirm the power supply voltage and frequency in accordance with the rating plate specified value Insert the power cord plug one end of the power Socket in H1 If the values on the rating plate are not observed the electrical and mechanical components may be damaged. I E F 6.5 Grinding operation Clamp/Release jars Place the grinding jars, filled with the material to be grinding and the milling balls, into the centering points of the holder and clamp firmly., Pull the locking pin E upwards from the groove and turn through 90.This unlocks the locking device. Turn the hand wheel F counterclockwise until the Max. clamping range is reached. Insert grinding jars I and press lightly into the centering point. Turn the hand wheel F clockwise until the grinding jars just fits, free of play in the holder. Then continue to turn the hand wheel F until the grinding jars is tightened.(but not too tight). Turn the locking pin E back through 90 until it engages in the groove again. Turn the hand wheel F clockwise lightly until the lock pin E is in the lower position. The engaged locking pin reliably prevents automatic opening of the grinding jar holder. If the locking pin E cannot be pulled upwards to release it, unlocking should not be forced with a hammer or similar tool. Otherwise the hardened locking pin can break off. Briefly turn the hand wheel F in the clockwise direction the locking pin E can then move freely again. To remove the grinding jar lift the locking pin and 13
15 turn the hand wheel in the opposite direction. In order to guarantee quiet running of the MBM-100 both milling positions must be loaded with approximately the same mass Ensure that the grinding jars are inserted correctly in the guides. Otherwise the grinding jars will be damaged when the machine is started When removing and opening hot grinding jars, always wear protective gloves. Danger of burning the hands Setting time Use the time key 11,12 / to setting required times 00:~99min, 00~59sec Setting speed Use the speed key 13,14 / to setting required speeds 200~2000RPM Storing the grinding parameters Storing or calling the preselected grinding parameters can be carried out only in the on mode. After switching on the MBM-100, on appears in the display 1 By pressing the button the next programmed position P1 to P9 can be obtained. After programmed position P9, on will reappears in the display 1. In the prog mode, all buttons, a part from Prog, Start and Stop are blocked. When the display shows on, the speed and the time are freely adjustable. When the display shows P1 to P9, grinding parameters can be stored and called allocating the storage location Press key once or several times until the required storage location P1-P9 has been reached. Press key, all displays will flash. 14
16 Set the time and speed. Press key once again, the values are stored. Flashing of the display stops, the adjustment interlock is activated and the milling parameters are stored. For example: programmed P1 Total grinding time: 3 min Speed: 1800 rpm Interrupt mode Interrupt time: 30 sec Pause time: 15 sec Press the prog key 9 until the display 1 Shows P1 Press the set key 10 Speed display will flash. once,the time and. Use the time key 11,12 / setting required total time: 3.0 min Use speed key13,14 / setting required Speed: 1800 rpm Press the mode key 15 once, into the interrupt mode At the same time LED 4 lights. Use the key 17,18 / setting Interrupt time: 30 sec Press the key 16 once, the LED 5 lights. Use the key 16 setting pause time: 15 sec Press the set key 10 once again,to conform and store all parameters Interrupt mode and time Press key once,led 4 is light (Into interrupt mode) Use the key 17,18 / setting interrupt time. Press key once, LED 5 is light Use the interrupt time key 17,18 / setting pause time START MBM
17 Setting grinding time In order t o guarantee Setting speed quiet running of the MBM-100 we recommend that grinding jars with the same mass as far Press as possible are key clamped in both milling positions. The MBM-100 can be start when closed the lid Don t open the lid when machine is running. During the process of grinding, don t open the lid If overload occurs, the MBM-100 will be stopped. Restart MBM-100 need to turn off the switch and turn on ag6a.i5n..7 STOP MBM-100 When the milling time has elapsed, the milling process is automatically ended. The display is reset to the last started value. At any time in the grinding process, press the key can stop the MBM-100 H Replacing the fuses The following visible type fuses are required for the MBM-100: 6 A/250V 2pc Replacing the fuses Unplug mains plug from the machine socket Pulling out the fuse holder H2 by the slot screwdriver Replace fuses Insert fuse holder H2 so that it engages. 7. Working instruction 7.1 General The MBM-100 is an ultramodern, high performance product from MRC. Owing to the large selection of accessories the oscillation mill, type MBM-100, is a machine with many different application possibilities in laboratories in industry and research. It is used mainly in the chemical and pharmaceutical sectors and in mineralogical and biological 7.2 Grinding operation Clamp the machine filled with material to be milled, together With the milling balls in the grinding jar holder as described. Close the hood. Set the milling parameters. Start the MBM-100. Do not open the LID during the milling process. 16
18 Milling cup volume in ml When handling liquid nitrogen always wear protective goggles and protective gloves. Liquid nitrogen has a temperature of 196 C and can Grinding parameters recommend: cause injury similar to burns or frostbite in contact with Milling material quantity theball skinfilling or eyes optional max.charging grain in ml Number dia. in mm size in mm min max 25 5~ ~ ~ Milling of materials which can cause a fire or explosion in the MBM-100 is prohibited. Please take any necessary measures to prevent danger to persons, depending on the dangerous nature of your sample. Please note that the properties, and therefore the dangerous nature of your sample, can change during the milling process 7.3 Safety instructions for handling liquid nitrogen The MBM-100 is also designed for cryogenic milling. As an accessory for cold milling, we also supply a cryo kit for cooling the grinding jars with liquid nitrogen. Only the stainless steel and the hard steel grinding jars can grinding with the liquid nitrogen Zirconia, agate, alumina, tungsten, carbide grinding jars can t grinding with the liquid nitrogen Grinding jars will be damaged 17
19 Please follow the safety regulations of the cooling liquid supplier. MRC excludes any liability claims whatsoever which may arise through the use of liquid nitrogen or similar materials.. Protective goggles also protect the eyes against serious injuries through flying glass splinters, which may be caused through bursting of glass containers as a result of low temperature tension. 7.4 Cleaning Do not clean the MBM-100 with running water. Danger to life through current surge Use only a cloth moistened with water. Cleaning agents and solvents must not be used Not for cleaning the milling tools either. 7.5 Cleaning the grinding jars Clean the grinding jars with the water. If need drying, put the grinding jars into the oven for drying process Grinding jars of materials and the drying temperature table Grinding jars of materials drying temperature( C) Stainless steel 180 C Hard steel 180 C tungsten >110 C Zirconia >110 C Agent >110 C alumina >110 C 7.6 Maintenance The MBM-100 is maintenance-free. When used properly no maintenance need be carried out. 18
20 Do not make any alterations to the machine and use only spare parts and accessories approved by MRC. Furthermore this will lead to loss of any kind of guarantee claims. 7.7 Wear The milling tools can become worn, depending on the frequency of the milling operation and the material to be milled. The grinding jars and balls should be regularly checked for wear and replaced if necessary. 7.8 Repair These operating instructions do not include instructions for repair. For your own safety repairs should be carried out only by MRC or an authorized representative (service technicians) H3 7.9 Checks Correct functioning of the lid switch must be Checked regularly: three months Switch on the machine with switch H3 Start milling operation with start button Lift the lid. The MBM-100 should be stop If this switching off function does not take place, the MBM-100 must be checked immediately by MRC or an authorized representative Copyright Distribution or duplication of this documentation,, is allowed only with the permission of MRC. Anyone violating is liable to pay damages Alteration Subject to technical alterations will without notice. 19
POLYMIX PX-IG 2000 Operating Instructions
POLYMIX PX-IG 2000 Operating Instructions Voltage D 100-120V, 50/60 Hz D 210-250V, 50/60 Hz Please check that the voltage is correct and corresponds with the nameplate on the back of the machine. Manual
More informationO p e r a t i n g I n s t r u c t i o n s B B J a w C r u s h e r
O p e r a t i n g I n s t r u c t i o n s B B 2 0 0 J a w C r u s h e r Retsch GmbH, Rheinische Str.36, 42781 Haan, Germany Doc. No. E98.053.9999 Information on these operating instructions The present
More informationUser Manual. TN6900 H&E Slide Stainer. Read Prior to Operation! Always keep this manual near the unit! WP
User Manual TN6900 H&E Slide Stainer Read Prior to Operation! Always keep this manual near the unit! WP47777 05.06.15 User Manual TN6900-H&E Slide Stainer 888.708.5233 Info@TannerScientific.com www.tannerscientific.com
More informationPS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.
PS07214 4 1/2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
More informationCombiGrinder. Instruction manual. Grinder for cattle, horse and pet clipper blades. swiss made. Version/Index: CombiGrinder/A 09-16
swiss made CombiGrinder Grinder for cattle, horse and pet clipper blades Instruction manual Version/Index: CombiGrinder/A 09-16 1 Instruction manual / CombiGrinder Contents 1 Safety regulations 1.1 Symbols
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationEldex Column Heater. Operator s Manual
Eldex Eldex Column Heater Operator s Manual Eldex Laboratories, Inc. 30 Executive Court Napa, CA 94558 Tel: (707) 224-8800 Fax: (707) 224-0688 www.eldex.com Rev. B: 081700 2000Eldex Laboratories, Inc.
More informationHI COD REACTOR and Test Tube Heater 2008 Series
Instruction Manual HI 839800 COD REACTOR and Test Tube Heater 2008 Series www.hannainst.com This Instrument is in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna product.
More informationLow Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual
Low Speed Centrifuge Model XC-2415 Model XC-2450 Operating Manual Before using this product, please read this manual carefully to learn about the available features to obtain the best results of this equipment.
More informationMillo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A
Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...
More informationINSTRUCTION MANUAL MODEL: 690E
1 INSTRUCTION MANUAL ALEKO Drywall Sander MODEL: 690E READ THROUGH CAREFULLY AND UNDERSTAND THESE INSTRUCTIONS BEFORE USE Visit our web site for more great products, parts and accessories: 2 3 4 5 6 Caution!
More informationInstallation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro
Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2
More informationFisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual
Fisher Scientific Isotemp Muffle Furnace 550 Series Instruction Manual Model 14 Catalog No: 10-550-14 & 14A Model 58 Catalog No: 10-550-58 Model 126 Catalog No: 10-550-126 Service Division (Repairs):
More informationOperating instructions Page 12. Wine storage cabinet WKt
Operating instructions Page 12 Wine storage cabinet EN 7083 487-01 WKt Disposal notes The appliance contains reusable materials and should be disposed of properly - not simply with unsorted household refuse.
More informationTTV 4500 / TTV 4500 HP / TTV 7000
TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating
More informationSYMS III MANUAL SEALER
MANUAL SEALER For CBS High Security straws, CBS High Security tubes and HSV High Security Vitrification Straw Copyright Cryo Bio System 2015 Cryo Bio System - ZI n 1 Est 61300 L Aigle contact@cryobiosystem-imv.com
More informationES-20 Orbital Shaker-Incubator
Medical Biological Research & Technologies ES-20 Orbital Shaker-Incubator Operating Manual Certificate for versions: V.2AD V.2AE Contents 1. Safety Precautions 2. General Information 3. Getting Started
More information20-GALLON PARTS WASHER OWNER S MANUAL
20-GALLON PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
More informationCorning LSE Benchtop Shaking Incubator
Corning LSE Benchtop Shaking Incubator INSTRUCTION MANUAL Models 6790 (120V US) 6791 (230V EU) Table of Contents 1.0. GENERAL INFORMATION GENERAL INFORMATION... 1 1.1 Definition... 1 1.2 Key features...
More informationMill, Ultra-Centrifugal STANDARD OPERATING PROCEDURE
STANDARD OPERATING PROCEDURE Mill, Ultra-Centrifugal Model: ZM-1 Manufacturer: Retsch GmbH & Co. KG Location: Dry Processing Pilot Plant, 1851 Food Sciences Building Publication Date: 08/29/2014 Iowa State
More informationVACUUM PACKAGING MACHINE
www.sintro.com.au VACUUM PACKAGING MACHINE Production date: USER MANUAL User Manual Version 0 Int DORS LLC 2014 CONTENTS CONSUMER INFORMATION... 4 PURPOSE... 4 GENERAL INFORMATION... 5 DESCRIPTION... 6
More informationCompressed-air grinder. AirMAX 230F. Instruction manual
Compressed-air grinder AirMAX 230F Instruction manual 1 List of Contents 1 List of contents... Page 02 2 Tips on using the manual... Page 03 3 Safety instructions... Page 04 4 Warranty/Identification...
More informationINSTRUCTIONS MANUAL PLANETARY MIXER. Model BPS-05
36214.0 - Março/2009 INSTRUCTIONS MANUAL PLANETARY MIXER Model BPS-05 SUMMARY 1. Introduction 01 1.1 Safety 01 1.2 Main Components 1.3 Technical Characteristics 01 02 2. Installation and Pre operation
More informationINSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer
INSTRUCTION MANUAL Instruction Manual High Throughput Homogenizer Table of Contents Package Contents.............. 1 Warranty.............. 1 Introduction.............. 2 Installation.............. 2 Maintenance
More information1. CONDITIONS FOR USE 2. SAFETY
1. CONDITIONS FOR USE This micro abrasive blaster may only be operated: Indoors; Below 6500 ft above sea level altitude; Ambient air temperature between 40-105 F (5-40 C); Maximum relative humidity of
More informationUVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies
Medical Biological Research & Technologies DNA/RNA UV-cleaner box UVT-B-AR Operating Manual Certificate for versions: V.3AA V.3AB V.3AD V.3AE V.3A04 Contents 1. Safety P recautions 2. General Information
More informationHigh-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.
High-Pressure Washer BY02-VBP-WTH BY02-VBP-WTR CAUTION : Do not use this device before reading the instructions. 1 1. Safety Instructions The appliance has been designed solely for private use outdoors
More informationSilent TS. Nr / Content Introduction...1 Symbology...1 Information for Operators...2. Introduction.
Silent TS Nr. 2921-0050 / 2921-1050 ENGLISH Content Introduction...1 Symbology...1 Information for Operators...2 Operating Instructions 1. Setup and Commissioning...2 1.1 Setup... 2 1.2 Connection to the
More informationInstructions manual DEHUMID HP50
Instructions manual DEHUMID HP50 Table of contents 1. Unpacking 3 2. Intended use 3 3. Disposal 3 4. Safety instructions 3 5. Functional principle 4 6. Automatic defrosting system 4 7. Set up and transportation
More informationOperating instructions Page 12. Wine storage cabinet WKt
Operating instructions Page 12 Wine storage cabinet 7083 489-00 WKt Disposal notes The appliance contains reusable materials and should be disposed of properly - not simply with unsorted household refuse.
More informationGrinding mill MISTRAL 50L (art. 650P)
Grinding mill MISTRAL 50L (art. 650P) USE AND MAINTENANCE MANUAL RIVER SYSTEMS SRL Via Marco Polo, 33-35011 Campodarsego (Padova) Italy Tel. +39-049-9202464 - Fax: +39-049-9216057 - e-mail: info@riversystems.it
More information3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9
3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL Model # 4KTV9 QUALITY GUARANTEE: Should a Westward product fail to perform satisfactorily due to defect or poor workmanship within one
More informationIKA WERKE. IKA Vibrax VXR basic BETRIEBSANLEITUNG D 3 OPERATING INSTRUCTIONS GB 7 MODE D EMPLOI F 11. VXR Reg.-No
31 791 00 IKA WERKE IKA Vibrax VXR basic BETRIEBSANLEITUNG D 3 OPERATING INSTRUCTIONS GB 7 MODE D EMPLOI F 11 Reg.-No. 4343-01 Contens Page Guarantee 2 Safety instructions 7 Proper use 8 Unpacking 8 Useful
More informationAUTOMATIC SLICING MACHINE
AUTOMATIC SLICING MACHINE Instruction for use and maintenance Noaw s.r.l. Via Colombera, 27 21048 Solbiate Arno (VA) Tel. +39 0331 219 723 - fax. +39 0331 216 197 e-mail: noaw@noaw.it http://www.noaw.it
More informationCentrifuge/Vortex for PCR plates CVP-2
Centrifuge/Vortex for PCR plates CVP-2 Operating instructions For version V.1GW Contents 1. Safety Precautions... 3 2. General Information... 5 3. Getting started... 6 4. Operation... 8 5. Specifications...
More informationDrink Mixer Operation Manual
Drink Mixer Operation Manual Page 3 READ BEFORE USE. 840177410 10/14 Mixer Safety IMPORTANT SAFETY INSTRUCTIONS Your safety and the safety of oth ers is very important. We have provided many important
More informationINFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and
More informationMST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL
MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE OXYGEN MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF OXYGEN IN ITS SURROUNDINGS 07/11
More informationTable of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage
Table of Contents 1 Features 2 Setup 3 Cautions 4 Description of the parts 5 Temperature Controls 6 Maintenance and Storage 7 Troubleshooting 8 Warranty 9 Technical Specifications -2- Safety warnings Before
More informationST1. Mod. USE AND MAINTENANCE MANUAL
Mod. USE AND MAINTENANCE MANUAL 2 Use and Maintenance Manual ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More informationOPERATION AND MONTAGE MANUAL ROOF FANS
NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this
More informationInstruction Manual. Juice Extractor. Model: ESI Dezembro/2008
Instruction Manual Juice Extractor 36202.6- Dezembro/2008 Model: ESI 5. PROBLEMS ANALYSIS and SOLUTIONS 5. 1 Problems, Causes and Solutions The Juice Extractor Mod. ESI were designed to operate with the
More informationPFS SERIES. Foot Impulse Stamping Sealers. Operational Manual PFS-350 PFS-450 PFS-650
PFS SERIES Foot Impulse Stamping Sealers Operational Manual PFS-350 PFS-450 PFS-650 Congratulations on your purchase of a new Foot Impulse Stamping Sealer. This machine will seal just about any thermo-sealable
More informationDOC JAN06 LT 200
DOC022.98.00742.JAN06 LT 200 DOC022.98.00742.JAN06 Thermostat LT 200 USER MANUAL (english) January 2006, Edition 2 Hach Lange GmbH, 2006. All rights reserved. Printed in Germany. CK/SK 42 Table of Contents
More informationOperating Manual. English. Refrigerators for chemicals KRC 50 KRC 180
English Operating Manual Refrigerators for chemicals KRC 50 KRC 180 1.951.6610-V1 12/12 JULABO GmbH 77960 Seelbach / Germany Tel. +49 (0) 7823 / 51-0 Fax +49 (0) 7823 / 24 91 info@julabo.de www.julabo.de
More informationMST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL
MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..
More informationOperating and Maintenance Instructions
EATON Germany GmbH Werk Lohmar D-53797 Lohmar Operating and Maintenance Instructions WALFORM Machine Electronically controlled - Conforms to CE MEG-WF385X Status: Sept 2011 MEG-WF385X_Stand Sept 2011 SUITABILITY
More information(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)
Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment
More informationThermal Stripper, TSAB-40 User Manual
Thermal Stripper, TSAB-40 User Manual User Manual Version 1.4 Table of Contents Introduction 4 Safety Considerations 5 Components 6 External Overview 7 Fiber Holder Platform Installation 8 Operation 12
More informationOWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions
634 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901 Includes: Installation
More informationSBU 7730NP SBU 7790NP. EN Super Blender. Copyright 2016, Fast ČR, a.s
SBU 7730NP SBU 7790NP EN Super Blender - 1 - EN Super Blender Important safety instructions READ CAREFULLY AND STORE FOR FUTURE USE. This appliance may be used by persons with physical or mental impairments
More informationUser Manual. Moisture Analyzer HE53
User Manual Moisture Analyzer HE53 Overview Heating Module 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 17 19 20 Legend 1 Heating module 2 Handles for opening heating module 3 Protective glass 4 Reflector
More informationDigital 7 Square Plate Magnetic Stirrer
Digital 7 Square (Hotplate) Magnetic Stirrer User Manual MS7-Pro Digital 7 Square Plate Magnetic Stirrer MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer Please read the User Manual carefully before
More informationOperating Manual. Combination Table Sealing Press. Series: Classic. CiMa-Pak Corporation Montreal Toronto New York. Telephone:
Operating Manual Combination Table Sealing Press Series: Classic CiMa-Pak Corporation Montreal Toronto New York Telephone: 1-877-631-2462 Translation This operating manual has been translated from the
More informationOPERATING MANUAL Sepor Mini-Pulverizer
SEPOR, INC 718 N FRIES AVE. WILMINGTON, CA 90744 310 830 6601 Fax: 310 830 9336 info@sepor.com OPERATING MANUAL Sepor Mini-Pulverizer Instructions for Operating and Maintenance The Sepor Mini-Pulverizer
More informationOPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART
OPERATING MANUAL for the modular heat presses Secabo TC5 SMART and TC7 SMART Congratulations on the purchase of your Secabo heat press! Please read this operating manual carefully to ensure a smooth production
More informationVARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #
R3.5 VARIABLE SPEED GRINDER SERIAL # MANUAL VERSION CONFORMS TO UL STD 763, NSF/ANSI STD 8 CERTIFIED TO CSA STD C22.2 #95 CONFORMS TO CE, IEC TESTED 2. Introduction WARNING: To limit risk of personal injury
More informationOperator's Manual. PCP October 2017
Operator's Manual PCP-0001.2 October 2017 Table of Contents Introduction...4 Intended Use...4 Safety Information...5 Specifications...7 Operating Conditions...7 Lifting and Storing...8 Installation...10
More informationTornado Operations & Maintenance Manual
Tornado Industries, LLC 333 Charles Court West Chicago, IL 60185 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99414 Form No. L9740AB Tornado Industries, LLC. All rights reserved
More informationSYMS II MANUAL SEALER
SYMS II MANUAL SEALER Dedicated to CBS High Security straws, CBS High Security tubes, and HSV High Security Vitrification Kits Copyright Cryo Bio System 2010 Cryo Bio System - ZI n 1 Est 61300 L Aigle
More information4-GALLON MOBILE PARTS WASHER
Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure
More informationService package PDAD- -SP (en) Assembly instructions d [ ]
Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with
More informationOPERATION AND MONTAGE MANUAL ROOF FANS
NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the
More informationinfrared paraffin / kerosene / diesel heater
instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
More informationOperating Instructions
Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns
More informationOperator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!
Operator s Manual The Bullet Blender 50 BB50-AU, BB50-DX Congratulations! Congratulations on your purchase of a Bullet Blender 50 by Next Advance, Inc., for mixing, lysing, disrupting, and homogenizing
More informationAPPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING
Thank you for choosing the Biomega BioClave steam sterilizer. Your steam sterilizer has been CE certified and designed with durability, reliability, and safety in mind. It is your responsibility to install
More informationInstruction Manual Suppository Penetration Tester. Type PM 30
Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *
More informationCAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE
User instructions Model X46 Escalator and Travelator cleaner CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-7845-0000 Iss.1 07/04 Fig 1 Fig 2 2 Contents Page 1 Product information... 4 1.1
More informationSilent TS. Nr / Ideas for dental technology / A. Made in Germany
Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050
More informationTelephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A
Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if
More informationMODEL 7000 SUCTION UNIT
MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices
More informationOPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationRules for Safe Operation
Rules for Safe Operation Important: Do not attempt to operate the CleanStation until you have read thoroughly and understand all instructions and safety rules contained in this manual. Failure to comply
More informationLaboport Chemically-resistant Laboratory Pumps and Systems
Operating Instructions Read and observe these Operating Instructions! Laboport Chemically-resistant Laboratory Pumps and Systems N 810 FT.18 N 820 FT.18 N 840 FT.18 N 840.1.2 FT.18 N 810.3 FT.18 N 820.3
More informationINSTRUCTIONS AND WARRANTY
INSTRUCTIONS AND WARRANTY MODEL: SB400E SALTON 450W STAINLESS STEEL GLASS JUG BLENDER Congratulations on purchasing our Salton 450W Stainless Steel Glass Jug Blender. Each unit is manufactured to ensure
More informationOperating instructions Page 12. Freezer Read the operating instructions before switching on for the first time GGU 15
Operating instructions Page 12 Freezer Read the operating instructions before switching on for the first time 7083 005-00 GGU 15 Content Description of the appliance... 12 Noise emissions from the appliance...
More informationSpecifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1
Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)
More informationInstruction Manual Centrifuge LC 6 with horizontal rotor 6 x
Instruction Manual Centrifuge LC 6 with horizontal rotor 6 x SARSTEDT-No.: 90.184.500 V. 2.1.2 / 01.2009 Table of contents Page E- 1. Device data... 3 2. Manufacturer's address... 3 3. Important notes...
More informationOscillating Belt/Spindle Sander 230V
Oscillating Belt/Spindle Sander 230V Model no: SM1300 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly
More informationFC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols...
FC 5 FC 5 Premium OPERATOR MANUAL Floor Cleaner.................2 MANUAL DE USUARIO Limpiador de piso............22 MANUEL D UTILISATION Nettoyant pour sols...........44 59682960 2018.03 FLOOR CLEANER
More informationASPIRE Laboratory Aspirator
ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY
More informationGilson Silent Sifter SS-21 & SS-22
Gilson Silent Sifter SS-21 & SS-22 Safety Instructions WARNING! This machine operates on electric current. Improper operation results in electric shock, electrocution, or an explosion! 1. ALWAYS ensure
More informationSC250X FLOOR GRINDER OPERATIONS MANUAL
Unit 4/1 Rocklea Drive Port Melbourne Vic 3207 1300 109 108 www.traxxcp.com.au SC250X FLOOR GRINDER OPERATIONS MANUAL The contents of this Operations Manual are the copyright of the publisher and may not
More informationLABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems
LABOPORT Chemically-resistant Laboratory Pumps with Modular Accessories Operating Instructions for Laboratory Pumps and for LABOPORT Systems SR..., SH, SC, SCC UN810FTP UN820FTP UN840FTP UN810.3FTP UN820.3FTP
More informationTTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN
TTK 75 E EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport... 05 Operation...
More informationMixer with Lifting Cart STANDARD OPERATING PROCEDURE
STANDARD OPERATING PROCEDURE Mixer with Lifting Cart Model: XD-30VM Manufacturer: SPX Corporation, Lightnin Mixers Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 03/04/2014
More informationkéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=
NJUMMJVQQJOOQP ïïïk~êåjòçåékåçã kéìíê~iqdlééê~íáçåëj~åì~ä m^dbnlcnm kéìíê~iqdqìåöëíéådêáåçéê lééê~íáçåëj~åì~ä ^o`jwlkbk`lj IfåÅ. OMVNi~ëm~äã~ëaêáîÉpíÉK` `~êäëä~çi`^vomnnjnrrn qéäwtsmkvpnknrmm UMMKVQQKOOQP
More informationRead these instructions before using and keep them available at all times!
200065 V2/0614 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about
More informationSpiral Dough Mixer. Instruction manual. Model: CP821
Spiral Dough Mixer Instruction manual Model: CP821 SPARE PARTS LIST OF CP821 NO. Description QTY. NO. Description QTY. 1. Small chain wheel of main shaft 1 29. Chain 06B-1-70L 2 2. Big chain wheel 3 30.
More informationOperating manual Spare parts list Stone cutoff saw TME700P
Operating manual Spare parts list Stone cutoff saw TME700P Index «000» 10995348 en I 16.07..2015 Manufacturer's address: TYROLIT Hydrostress AG Witzbergstrasse 18 CH-8330 Pfäffikon Switzerland Tel. +41
More informationDigital Heat Block User Manual
Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in
More informationSAMPLE PREPARATION SPECTRAL PG/AG. metkon.com
SAMPLE PREPARATION SPECTRAL PG/AG metkon.com CUP GRINDER FOR IRON & STEEL SPECTRAL PG/AG Sample preparation of metals and materials have become more and more important because of the rapid development
More informationFSW300 Series Flow Switch
. FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of
More informationVADA - Rain2Main Automatic Rainwater Controller
PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS Mechanical Sand Equivalent Shaker ELE International Chartmoor Road, Chartwell Business Park Leighton Buzzard, Bedfordshire, LU7 4WG England phone: +44 (0) 1525 249200 fax: +44 (0)
More information235L G. Original-Gebrauchsanleitung V1/1115
235L 700335G Original-Gebrauchsanleitung V1/1115 GB/UK ENGLISH Table of contents 1.Safety... 20 1.1 Safety instructions... 20 1.2 Key to symbols... 23 1.3 Proper use... 24 2. General information... 25
More informationSMHA Hatch High temperature fan HT-fan Installation and Maintenance
High temperature fan HT-fan Installation and Maintenance 22.8.2012 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance
More informationOperation Manual for Drying Storage Cabinet with Drying Unit U-5002
Operation Manual for Drying Storage Cabinet with Drying Unit U-5002 (software version 4-09 and above) Aplicable to the following cabinets: MSD-601-52, MSD-1202-52, MSD-1222-52 HSD-241-52, HSD-351-52, HSD-472-52,
More informationRead the entire manual before using this Machine.
COLD SPARK MACHINE X-BLITZZX2 FIREWORKS SIMULATOR SAFE COLD BURN SPARK EFFECT MACHINE INDOOR / OUTDOOR SPARK FOUNTAIN NON-HAZARDOUS EFFECT - NO FIREWORK RISKS NO EXPLOSIVE CONTENT - NOT PYROTECHNIC ENVIRONMENTAL
More information