DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC
|
|
- Dorthy Ferguson
- 6 years ago
- Views:
Transcription
1 SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC ARG30ALC ARG30RLC ARY30ALC ARY30RLC ART30ALC ART30RLC AOG25ANBL AOG25RNBL AOY25ANBL AOY25RNBL AOT25ANAL AOT25RNAL AOT25RZDL AOG30AMBL AOG30AMBH AOG30RMBL AOY30AMBL AOY30AMBH AOY30RMBL AOT30AMBL AOT30RMBL C O N T E N T S SPECIFICATIONS OUTLINE AND DIMENSIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM DIAGRAM INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM OUTDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM ERROR CONTENTS DISASSEMBLY ILLUSTRATION PARTS LIST ACCESSORIES
2 TYPE COOLING COOLING & HEATING INDOOR UNIT ARG25ALC ART25ALC ARG25RLC ART25RLC ARY25ALC ARY25RLC OUTDOOR UNIT AOG25ANBL AOT25ANAL AOG25RNBL AOT25RNAL AOT25RZDL AOY25ANBL AOY25RNBL COOLING CAPACITY (kw) HEATING CAPACITY (kw) POWER SOURCE V Hz 50 RUNNING CURRENT (COOL) A RUNNING CURRENT (HEAT) A INPUT WATTS (COOL) kw INPUT WATTS (HEAT) kw E.E.R (COOL) kw/kw E.E.R (HEAT) kw/kw STARTING CURRENT A MOISTURE REMOVAL l/h COMPRESSOR TYPE CODE Hermetic type, 2 pole, Single phase, Induction motor 2JS438D5CA02 REFRIGERANT R-22 g AWG5532EXC 2100 FAN SPEED INDOOR HIGH r.p.m 890 FAN SPEED INDOOR MED r.p.m 820 FAN SPEED INDOOR LOW r.p.m 745 FAN SPEED OUTDOOR r.p.m AIR FLOW INDOOR m3/h 1100 (at 100Pa) AIR FLOW OUTDOOR m3/h DIMENSIONS IN (H x W x D) mm 270 x 1210 x 700 DIMENSIONS OUT (H x W x D) mm 643 x 840 x x 900 x x 840 x 336 WEIGHT IN (NET/GROSS) kg 43 / 58 WEIGHT OUT (NET/GROSS) kg 65 / / / 77 MAX PIPE LENGTH/HEIGHT m 25 / 15 REMOTE CONTROLLER TYPE WI x 900 x / 82 REFRIGERANT CHARGE (FULL CHARGE AMOUNT) PIPE LENGTH 7.5m (25ft) 10m (33ft) 15m (49ft) 20m (66ft) 25m (82ft) Additional refrigerant ARG25ALC / AOG25ANBL 2100g (74.1 oz) 2143g (75.6 oz) 2228g (78.6 oz) 2313g (81.6 oz) 2398g (84.6 oz) 17g/m (0.18 oz/ft) ARY25ALC / AOY25ANBL ART25ALC / AOT25ANAL 2050g (72.3 oz) 2100g (74.1 oz) 2200g (77.6 oz) 2300g (81.1 oz) 2400g (84.7 oz) 20g/m (0.22 oz/ft) ARG25RLC / AOG25RNBL 2200g (77.6 oz) 2300g (81.1 oz) 2500g (88.2 oz) 2700g (95.2 oz) 2900g (102.3 oz) 40g/m (0.43 oz/ft) ARY25RLC / AOY25RNBL ART25RLC / AOT25RNAL 2100g (74.1 oz) 2225g (78.5 oz) 2475g (87.3 oz) 2725g (96.1 oz) 2975g (104.9 oz) 50g/m (0.54 oz/ft) ART25RLC / AOT25RZDL 1
3 TYPE COOLING COOLING & HEATING INDOOR UNIT ARG30ALC ART30ALC ARG30RLC ART30RLC ARY30ALC ARY30RLC OUTDOOR UNIT AOG30AMBL AOG30AMBH AOT30AMBL AOG30RMBL AOT30RMBL AOY30AMBL AOY30AMBH AOY30RMBL COOLING CAPACITY (kw) HEATING CAPACITY (kw) POWER SOURCE V Hz 50 RUNNING CURRENT (COOL) A RUNNING CURRENT (HEAT) A INPUT WATTS (COOL) kw INPUT WATTS (HEAT) kw E.E.R (COOL) kw/kw E.E.R (HEAT) kw/kw STARTING CURRENT A MOISTURE REMOVAL l/h 4.0 COMPRESSOR TYPE Hermetic type, 2 pole, Single phase, Induction motor CODE NH52VNHT NHT52VAAT NH52VNHT NH52VNHT REFRIGERANT R-22 g FAN SPEED INDOOR HIGH FAN SPEED INDOOR MED FAN SPEED INDOOR LOW FAN SPEED OUTDOOR AIR FLOW INDOOR AIR FLOW OUTDOOR DIMENSIONS IN (H x W x D) DIMENSIONS OUT (H x W x D) WEIGHT IN (NET/GROSS) WEIGHT OUT (NET/GROSS) MAX PIPE LENGTH/HEIGHT REMOTE CONTROLLER TYPE r.p.m r.p.m r.p.m r.p.m m3/h m3/h mm mm kg kg m (at 100Pa) x 1210 x x 900 x / / / / / 15 WI REFRIGERANT CHARGE (FULL CHARGE AMOUNT) PIPE LENGTH 7.5m (25ft) 10m (33ft) 15m (49ft) 20m (66ft) 25m (82ft) 30m (98ft) Additional refrigerant ARG30ALC / AOG30AMBL 2400g (84.7 oz) 2450g (86.4 oz) 2550g (89.9 oz) 2650g (93.5 oz) 2750g (97.0 oz) 2850g (100.5 oz) 20g/m (0.22 oz/ft) ARY30ALC / AOY30AMBL ART30ALC / AOT30AMBL ARG30ALC / AOG30AMBH 2500g (88.2 oz) 2550g (89.9 oz) 2650g (9305 oz) 2750g (97.0 oz) 2850g (100.5 oz) 2950g (104.1 oz) 20g/m (0.22 oz/ft) ARY30ALC / AOY30AMBH ARG30RLC / AOG30RNAL 2700g (95.2 oz) 2825g (100.5 oz) 3075g (108.5 oz) 3325g (117.3 oz) 3575g (126.1 oz) - 50g/m (0.54 oz/ft) ARY30RLC / AOY30RNAL AOT30RLC / AOT30RNAL 2
4 DIMENSIONS INDOOR UNIT Models : ARG25ALC ARY25ALC ART25ALC ARG30ALC ARY30ALC ART30ALC ARG25RLC ARY25RLC ART25RLC ARG30RLC ARY30RLC ART30RLC Unit : mm 26 1, ,063 1, OUTDOOR UNIT Models : AOG25ANBL AOY25ANBL AOG25RNBL AOY25RNBL 3
5 Models : AOT25ANAL AOT25RNAL AOT25RZDL Unit : (mm) Models : AOG30AMBH, AOG30RMBL AOY30AMBH, AOY30RMBL AOG30AMBL, AOT30RMBL AOY30AMBL, AOT30AMBL
6 CIRCUIT DIAGRAM Models : ARG25ALC ARY25ALC Models : ARG25RLC ARY25RLC 5
7 Models : ART25ALC Models : ART25RLC 6
8 Models : AOG25ANBL AOY25ANBL Models : AOT25ANAL SOFT STARTER GRAY 1 MAIN RELAY 5 BLUE FAN MOTOR R COMPRESSOR CAPACITOR BLUE INTERNAL OVERLOAD PROTECTOR S C COMPRESSOR START CAPACITOR 4 FUSE 5A 6 BROWN BROWN L N 3 2 (N) 1 TERMINAL CR COMPOSITE C OUTDOOR THERMOSTAT FAN MOTOR CAPACITOR H L BLUE TO POWER SUPPLY TO INDOOR UNIT 7
9 Model : AOG25RNBL AOY25RNBL 8
10 Model : AOT25RNAL Model : AOT25RZCL SOFT STARTER GRAY R BLUE OVERLOAD PROTECTOR S C COMPRESSOR CAPACITOR START CAPACITOR COMPRESSOR MAIN RELAY NO COM TO POWER SUPPLY GREEN E BLUE SOLENOID COIL THERMISTOR (PIPE TEMP.) GRAY GRAY YELLOW FAN MOTOR CAPACITOR TERMINAL THERMISTOR (OUTDOOR TEMP.) YELLOW PURPLE PURPLE TRANSFORMER THERMISTOR (DISCHARGE TEMP.) BROWN BROWN CN11 CN12 CN13 CONTROL BOARD CN15 CN9 CN1 CN4 CN3 CN2 CN WV L N 3 2 (N) 1 BLUE BLUE FUSE T 3.15A 250V FAN MOTOR TO INDOOR UNIT 9
11 Model : ARG30ALC ARY30ALC Model : ART30ALC 10
12 Models : AOG30AMBL, AOY30AMBL INTERNAL OVERLOAD PROTECTOR COMPRESSOR S C R CR COMPOSITE C H BLUE L OUTDOOR THERMOSTAT 1 5 CONNECTOR THERMAL PROTECTOR FAN MOTOR 4 6 MAIN RELAY FUSE 5A COMPRESSOR CAPACITOR GREEN/YELLOW BROWN BROWN FAN MOTOR CAPACITOR TERMINAL L N 3 2(N) 1 Model : AOT30AMBL SOFT STARTER INTERNAL OVERLOAD PROTECTOR COMPRESSOR S C GRAY R BLUE COMPRESSOR CAPACITOR (START) COMPRESSOR CAPACITOR (RUN) CONNECTOR THERMAL PROTECTOR MAIN RELAY BROWN BROWN FUSE 5A BLUE H C L FAN MOTOR CAPACITOR OUTDOOR THERMOSTAT FAN MOTOR GREEN/YELLOW TERMINAL L N 3 2(N) 1 11
13 Models : AOG30AMBH, AOY30AMBH INTERNAL OVERLOAD PROTECTOR COMPRESSOR C THERMAL SWITCH CONNECTOR THERMAL PROTECTOR COMPRESSOR CAPACITOR MAIN RELAY S R BROWN BROWN BROWN BLUE H C L OUTDOOR THERMOSTAT FUSE 5A FAN MOTOR FAN MOTOR CAPACITOR PRESSURE SWITCH GREEN/YELLOW TERMINAL L N 3 2(N) 1 12
14 Model : ARG30RLC ARY30RLC Model : AOG30RMBL AOY30RMBL 13
15 Model : ART30RLC Model : AOT30RMBL SOFT STARTER GRAY R BLUE OVERLOAD PROTECTOR S C COMPRESSOR CAPACITOR START CAPACITOR COMPRESSOR MAIN RELAY 1 4 NO COM GREEN BLUE E SOLENOID COIL THERMISTOR (PIPE TEMP.) GRAY GRAY FAN MOTOR CAPACITOR YELLOW YELLOW THERMISTOR (OUTDOOR TEMP.) PURPLE PURPLE TRANSFORMER THERMISTOR (DISCHARGE TEMP.) BROWN BROWN CN11 CN12 CN13 PRINTED CIRCUIT BOARD CN15 CN9 CN1 CN4 CN3 CN2 CN2 CN GREEN/YELLOW 4WV L N 3 2 (N) 1 TERMINAL BELT HEATER BLUE BLUE FUSE T 3.15A 250V FAN MOTOR TO POWER SUPPLY TO INDOOR UNIT 14
16 Models : REFRIGERANT SYSTEM DIAGRAM ARG25ALC / AOG25ANBL ARY25ALC / AOY25ANBL ART25ALC / AOT25ANAL INDOOR UNIT OUTDOOR UNIT Refrigerant pipe 9.52 mm (3/8") Capillary tube Dryer Evaporator Condenser Refrigerant pipe mm (5/8") Charging valve Accumulator Compressor Models : ARG25RLC / AOG25RNBL ARY25RLC / AOY25RNBL ART25RLC / AOT25RNAL ART25RLC / AOT25RZDL INDOOR UNIT OUTDOOR UNIT Refrigerant pipe Check valve 9.52mm(3/8") Dryer Strainer Strainer Evaporator 4-Way valve Muffler Condenser Refrigerant pipe 15.88mm(5/8") Charging valve Cooling Heating : Flare coupling 15 Accumulator Compressor
17 Models : ARG30ALC / AOG30AMBL ARY30ALC / AOY30AMBL ART30ALC / AOT30AMBL INDOOR UNIT Refrigerant pipe OUTDOOR UNIT Capillary tube 9.52mm(3/8") Dryer Compressor Evaporator Condenser Refrigerant pipe 15.88mm(5/8") Charging valve Accumulator Check joint Models : ARG30RLC / AOG30RMBL ARY30RLC / AOY30RMBL ART30RLC / AOT30RMBL INDOOR UNIT Refrigerant pipe 9.52mm(3/8") Strainer OUTDOOR UNIT Capillary tube Distributor Dryer Evaporator Accumulator Compressor Condenser Check joint Refrigerant pipe 15.88mm(5/8") 4-Way valve Cooling Heating : Flare coupling Charging valve 16
18 Models : ARG30ALC / AOG30AMBH ARY30ALC / AOY30AMBH INDOOR UNIT OUTDOOR UNIT Refrigerant pipe Capillary tube 9.52mm(3/8") Dryer Compressor Evaporator Condenser Refrigerant pipe 15.88mm(5/8") Charging valve Accumulator Pressure switch Check joint 17
19 I N D O O R P R I N T E D C I R C U I T B O A R D C I R C U I T D I A G R A M Models : ARY25ALC ARY30ALC ARG25ALC ARG30ALC ART25ALC ART30ALC CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ARY25ALC,ARG25ALC,ART25ALC : EZ-00209WSE-C ARY30ALC,ARG30ALC,ART30ALC : EZ-0020PWSE-C MANUAL AUTO SWITCH 440V 6uF 18
20 Models : ARY25RLC ARG25RLC ART25RLC UL1015 AWG18 DRAIN PUMP L N TM101 POWER SOURCE 240V 50Hz UL1015 AWG18 UL1015 AWG18 TM102 JM6 FAN MOTOR TERMINAL BOARD OUTDOOR UNIT R1 3.3 <RGGS-5W> E F M D1 D3SB60 K4 G5NB-1A DC12V CN6-2 CN6-1 FH1 F <BET> UL1015 AWG16 GREEN C <RE> C5 100/ 450V R <1/2W> CN6 B2P3-VH-B-E BLUE FH2 SA101 RA-362M + VA <TNR> E101 W103 W104 CN4 FAN CAPACITOR B2P3-VH-B-Y 450V YELLOW 2.3uF UL1015 AWG20 UL1015 AWG22 UL1015 AWG20 CN5 B6P11-VH-B UL1015 AWG22 UL1015 AWG22 BLUE UL1015 AWG22 PURPLE UL1015 AWG22 PINK R4 330K <SPRH-2W> Q1 2SC4236 R3 100 Q2 2SC1815 R2 1.5 <RSP2-2W> ELF17N015A LF101 VA <TNR> UL1015 AWG18 UL1015 AWG18 UL1015 AWG18 UL1015 AWG22 C <F> C <F> C <ECQB> D2 D1FL20U D3 MTZJ5.1B R7 330 <1/4W> POWER SUPPLY PCB CN4-1 CN4-2 CN1-1 CN1-2 CN1-3 CN1 B3P5-VH-B-C CN5-1 CN5-2 CN5-6 SL CN5-5 L CN5-4 M CN5-3 H C6 4700P <ECQM> D5 1SR D10 1SR C <YE> C <YE> + R6 100 <1/2W> D4 D1FL20U C8 100 /6.3V C <RE-C> K3 G5S-1 DC12V SW1 DSS803 NO.1 NO.2 NO.3 R5 62K <RSP2-2W> K1 G5S-1 DC12V K2 G5S-1 DC12V TEST T1 SWITCHING TRANSFORMER ZFT29B01 14V D6 D2FL20U PRIMARY C /25V R8 10K SECONDARY VA1 470 <TNR> SSR1 G3MC-201P-VD VA2 CN9-1 CN9-2 CN9-3 CN9-4 ZONE CONTROL SWITCHING REMOTE CONTROLLER CUSTOM CODE SWITCHING (R1) REMOTE CONTROLLER CUSTOM CODE SWITCHING (R2) + - CN9-5 CN9 B5P-SHF-1AA R39 10K ROOM TEMPERATURE CORRECTION (HEATING OPERATION) ROOM TEMPERATURE CORRECTION (HEATING OPERATION) R15 - R17 10K x 3 JM1 JM2 5V C <F> 5V SW2 DRS C IC10 R38 10K R37 10K JM3 IC V I O G C / 25V IC I O G HI2002 C <F> R93 - R96 10K x 4 5V C14 100/ 6.3V 5V R29 - R32 10K x 4 14V 5V 5V R21 - R24 10K x 4 K2 K1 K3 K4 5V C <F> R33 - R36 NC 1.0K x 4 C26 - C x 4 <F> 5 2 C <F> 3 14V 5V R10 10K IC5 (1/7) upa2003gr R14 10K Q3 DTC124EKA 8 C <F> 33 VSS1 JM10 71 I C R25 - R28 1.0K x 4 R42 1.0K R41 1.0K R40 1.0K R18 1.0K R19 1.0K R20 1.0K R59 10K C22 - C x 4 <F> C <F> C19 - C x 3 <F> R97 10K C <F> CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-00225HSE-C R98 10K CR <F> R9 390 IC5 (1/7) upa2003gr C <F> NC NC NC R99 10K CR <F> 1 P15 P P P P05 65 P VDD VSS0 72 XT2 56 P P P P P66 63 P02 40 P64 39 P63 38 P62 37 P61 36 P P16 P120 P122 VDD0 AVRF0 AVRF1 AVSS P65 P67 P30 45 P31 46 P32 50 P36 51 P37 19 P40 20 P41 21 P42 19 I C 1 P11 upd780058gc-497-8bt P70 P71 P72 P131 P46 P24 P23 P47 P57 P56 P51 P52 P53 P54 X1 X X1 CSTS0500MG03-T P03 64 P50 P55 P00 P121 P01 P12 P13 P14 P33 P P35 49 P45 24 P44 23 P43 22 XT1 73 RESET C <F> 60 CR <F> C <F> C <F> C P <R> NC NC NC NC R60 10K C P <R> 5V Q5 2SC2712 NC NC NC R55 10K C <F> 5V R77 - R79 10K x 4 R67 1.0K R51 1.0K R61 10K R91 10K R44 1.0K R46 1.0K R50 10K R67 10K 5V Q6 2SC2712 R81 1.0K R72 1.0K R71 1.0K C <F> Q7 2SC982 R92 10K 3 5V CR2 - CR5 10K x 4 R52 10K RJ2 10K RJ1 1.0K 5V 1 5V 2 IC8 PST600C R70 10K C1 0.1 <F> 5V R62 4.7K R R69 10K C <F> D0 D1 CK CS R80 10K 12V IC11-2 BA V R43 10K (1%) R K (1%) VCC GND NC NC IC7 BR93LC46RF 5V 12V D7 DA226U NO.3 FAN SWITCHING NO.2 FAN SWITCHING IC5 (1/7) 1 16 R K (1%) R64 28K (1%) 12V SW4 DSS803 NO.3 IC11-1 BA NO.2 NO.1 C <F> CN15-1 CN15-2 CN15-3 C <F> C <F> R58 10K R66 10K NO.1 ROOM TEMPERATURE CORRECTION (COOLING OPERATION) CN15 B3B-XARK-1-A 12V R75 10K R76 10K C <F> 14V R100 10K CN10-1 5V CN10-2 CN10 B3B-XAMK-1-A GREEN CN17 B3B-XAKK-1-A L2 L4 L3 CN17-1 CN17-2 CN17-3 5V CN8 B2B-XASK-1-A CN8-1 CN7 R49 1.0K HEATER UL1430 AWG22 UL1430 AWG22 5V TERMINAL BOARD FLOAT SWITCH CN8-2 B2B-XAKK-1-A CN7-1 GRAY UL1430 AWG22 CN7-2 REMOTE CONTROL UNIT EZ-002PHSE-R R48 10K GRAY Q4 DTC124EKA ROOM TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR 5V R CN14 B4B-XH-AM CN14-4 CN14-3 CN14-2 CN14-1 HA JEM-A
21 NOT USED Models : ARY30RLC ARG30RLC ART30RLC CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-002PHSE-C ROOM TEMPERATURE THERMISTOR REMOTE CONTROL UNIT CUSTOM CODE SWITCHING (R1) REMOTE CONTROL UNIT CUSTOM CODE SWITCHING (R2) PIPE TEMPERATURE THERMISTOR POWER SUPPLY PCB FAN SWITCHING RELAY PCB EZ-0950DHSE-K FAN SWITCHING ROOM TEMPERATURE CORRECTION ( COOLING OPERATION ) ZONE CONTROL SWITCHING ROOM TEMPERATURE CORRECTION ( HEATING OPERATION ) ROOM TEMPERATURE CORRECTION ( HEATING OPERATION ) 20
22 O U T D O O R P R I N T E D C I R C U I T B O A R D C I R C U I T D I A G R A M Models : AOY25RNBL AOG25RNBL CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-0028HUE-C POWER SOURCE 240V 50Hz 21
23 Model : AOT25RNAL CONTROLLERPCB ASSEMBLY ( MAIN PCB ) EZ-0028HUE-C POWER SOURCE 240V 50Hz 22
24 Model : AOT25RZDL CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-0029HUE-C POWER SOURCE 240V 50Hz 23
25 Models : AOY30RMBL AOG30RMBL CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-0028HUE-C POWER SOURCE 240V 50Hz 24
26 Model : AOT30RMBL CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-0028HUE-C POWER SOURCE 240V 50Hz 25
27 ERROR CONTENTS 1. IN DOOR U N IT W hen E E : E E blinks at the current tim e display, there is an error inside the air conditioner. If the S E T T IM E button ( ) and T E M P./DA Y button ( ) are pressed sim ultaneously for m ore than three seconds, the self diagnosis check will start and the error contents will be displayed at the current tim e display (Fig. 1). W hen the operation lam p lights, press the S T A R T /S T OP button and after operation lam p goes off, perform the sam e operation (Fig. 1). Process the error contents by referring to (Table 2). Fig. 1 NON STOP CLOCK TEMP AUTO C HIGH 1 2 TIMER MODE CLOCK ADJUST Error cord SET TIME TEMP./DAY FAN CONTROL ZONE ENERGY SAVE START/STOP ENERGY SAVE SET S top Operation. DAY OFF COOL DEFROST MASTER CONTROL Table TIMER MODE CLOCK ADJUST Error contents Communication error (indoor unit remote controller) Communication error (indoor unit outdoor unit) Room temperature sensor open SET AUTO SET TIME TEMP./DAY FAN CONTROL Room temperature sensor shortcircuited DAY OFF Indoor heat exchanger tem perature sensor open Indoor heat exchanger tem perature sensor shortcircuited Outdoor heat exchanger tem perature sensor open Outdoor heat exchanger tem perature sensor shortcircuited Power source connection error Float switch operated Outdoor temperature sensor open Outdoor temperature sensor shortcircuited MASTER CONTROL START/STOP 2. OU T DOOR U N IT W hen the outdoor tem perature drops, the outdoor unit's fans m ay switch to low speed. ERROR : HEAT & COOL (REV ERS E CYCLE ) ONLY T he LE D lam ps operate as follows (T able 3) according to the error contents. T he LE D lam ps are on the outdoor unit board. ON OFF LE D1 Quick flash continued ON OFF 1 quick flash repeated ON OFF 2 quick flash repeated ON OFF 0.1 sec. 0.5 sec. 0.5 sec. 0.5 sec. 2 sec. 2 sec. Error display 2 sec. 3 quick flash repeated 4 quick flash repeated 5 quick flash repeated 6 quick flash repeated 7 quick flash repeated 8 quick flash repeated ON OFF Table 3 LE D2 Quick flash continued ON OFF Lighting continued ON OFF Lighting continued ON OFF 0.1 sec. Lighting continued Lighting continued Lighting continued Lighting continued Lighting continued Lighting continued Error contents Model abnormal or EEPROM abnormal Power source connection error Discharge temperature sensor error Outdoor heat exchanger temperature sensor error Outdoor temperature sensor error Communication signal error Indoor unit error Discharge temperature abnormal High pressure abnormal W hen the fault is cleared, the LE D lam p goes off. However, for discharge pipe temperature abnormal and high pressure abnorm al, the LE D lam p lights continuously for 24 hours, as long as the power is not turned off. Discharge pipe temperature sensor open Discharge pipe tem perature sensor shortcircuited Outdoor high pressure abnormal Discharge pipe temperature abnormal M odel abnormal Indoor fan abnormal Outdoor signal abnormal Outdoor EEPROM abnormal 26
28 DISASSEMBLY ILLUSTRATION Model : ARG25ALC ARY25ALC ART25ALC ARG30ALC ARY30ALC ART30ALC ARG25RLC ARY25RLC ART25RLC ARG30RLC ARY30RLC ART30RLC 27
29 28
30 Models : ARG25ALC ARY25ALC ART25ALC ARG25RLC ARY25RLC ART25RLC 29
31 Models : ARG30ALC ARY30ALC ART30ALC ARG30RLC ARY30RLC ART30RLC 30
32 Models : AOG25ANBL AOG25RNBL AOY25RNBL
33 Models : AOG25ANBL AOG25RNBL 32
34 33
35 Model : AOG25ANBL
36 Models :AOG25RNBL AOY25RNBL
37 Models : AOT25ANAL AOT25RNAL AOT25RZDL
38 Models : AOT25ANAL
39 F C 107 D E A 55 B C Models : AOT25RNAL G
40 Model : AOT25RZDL
41 Models : AOG25ANBL, AOG25RNBL AOY25ANBL, AOY25RNBL AOT25ANAL, AOT25RNAL
42 Model : AOT25ANAL 41
43 Model : AOT25RNAL AOT25RZDL
44 Models : AOG30AMBH, AOG30RMBL AOY30AMBH, AOY30RMBL AOG30AMBL, AOT30RMBL AOY30AMBL, AOT30AMBL
45 Models : AOG30AMBH, AOG30RMBL AOY30AMBH, AOY30RMBL AOG30AMBL, AOT30RMBL AOY30AMBL, AOT30AMBL
46 Models : AOG30AMBH AOY30AMBH G
47 Models : AOG30AMBL AOY30AMBL AOT30AMBL
48 Models : AOG30RMBL AOY30RMBL AOT30RMBL J
49 Modes : AOG30AMBH AOY30AMBH D C
50 Modes : AOG30AMBL, AOY30AMBL, AOT30AMBL AOG30RMBL, AOY30RMBL, AOT30RMBL
51 Model : AOG30AMBL AOY30AMBL AOG30AMBH AOY30AMBH
52 Mode : AOT30AMBL
53 Modes : AOG30RMBL AOY30RMBL
54 Model : AOT30RMBL 53
55 AR AR AR AR 25ALC 25RLC 30ALC 30RLC P A R T S L I S T INDOOR UNIT Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. Part No. ARY25ALC ARY25RLC Ord. Ref. ARY25ALC ARY25RLC Description ART25ALC ART25RLC Q'ty No. ART25ALC ART25RLC ARG25ALC ARG25RLC ARG25ALC ARG25RLC 34 Capacitor (Fan Motor) Thermistor Assy Cord Holder Metal Thermistor Assy-Pipe Sirocco Fan Assy Controller PCB Assy Hex. Socket Screw Remote Control Unit Cabinet-Left Metal Remote Control Unit Rubber (Vibration-proof) (ART25ALC Only)(ART25RLC Only) 69 Cabinet-Right Metal Cap (Power) Intake Panel Top Plate Outlet Panel Assy Coupling Pipe Assy Base Assy Motor Fixture Casing Assy Loking Spacer Motor Fixing Table Assy Pipe Fixing Plate Separate Wall Control Box Metal-B Clamp NK-3N Clamp NK-4N Evaporator Assy Eva. Fixing Plate-E Drain Pan Assy Eva. Fixing Plate-L Fan Motor Assy-IN Distributor Assy Hanger Bracket Drain Cap Thermo. Spring-A Terminal-7P Rubber Bushing Power PWB Assy Clamp No Intake Seal Plate Clamp No Square Flange Assy Clamp SKB Control Box Metal-E Clamp SKB-3M Eva. Seal Plate Control Box Metal Assy Ord. Q'ty INDOOR UNIT Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. Part No. ARY30ALC ARY30RLC Ord. Ref. ARY30ALC ARY30RLC Description ART30ALC ART30RLC Q'ty No. ART30ALC ART30RLC ARG30ALC ARG30RLC ARG30ALC ARG30RLC 4 Emblem-Rear Control Box Metal Assy Capacitor (Fan Motor) Thermistor Assy Cord Holder Metal Thermistor Assy-Pipe Sirocco Fan Assy Controller PCB Assy Hex. Socket Screw Remote Control Unit Cabinet-Left Metal Remote Control Unit Rubber (Vibration-proof) (ART30ALC Only)(ART30RLC Only) 69 Cabinet-Right Metal Cap (Power) Intake Panel Top Plate Outlet Panel Assy Coupling Pipe Assy Base Assy Motor Fixture Casing Assy Loking Spacer Motor Fixing Table Assy Pipe Fixing Plate Separate Wall Control Box Metal-B Clamp NK-3N Clamp NK-4N Evaporator Assy Eva. Fixing Plate-E Drain Pan Assy Eva. Fixing Plate-L Fan Motor Assy Distributor Assy Thermo. Spring-A Drain Cap Rubber Bushing Terminal-7P Clamp No Power PWB Assy Clamp No Eva. Seal Plate Clamp SKB Relay PCB Assy Clamp SKB-3M Ord. Q'ty 54
56 AOY25ANBL AOG25ANBL AOY25RNBL AOG25RNBL OUTDOOR UNIT Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. AOY25ANBL AOG25ANBL AOY25RNBL AOG25RNBL Ord. Q'ty 2 Fan Cover Emblem-Rear "FUJITSU" Emblem-Rear "GENERAL" Cabinet-A, Painted Cabinet-C, Painted Connector Cover Shield Tube Assy-D Cabinet-B, Painted Base Assy, Painted Way Valve Assy Way Valve Assy Dryer Condenser Assy U-Pipe (Y) Accumulator Discharge Pipe Discharge Pipe Assy Compressor Cover-A Separate Wall Control Box Metal-A Control Box Metal-B Capacitor (Fan Motor) Cord Holder Metal Running Capacitor Capacitor Clamp Propeller Fan Assy Fan Motor Assy-Out Motor Fixing Table Assy Compressor Assy Special Nut M Special Nut M Rubber (Vibration-proof) Rubber Seat-A Terminal Cover Inlet Pipe (Dryer) Hex. Nut w/sp. Washer Clamp No Main Relay Power Relay Heat Thermistor Controller PCB Assy Way Valve Rubber Suction Pipe-C Comp. Plate Assy Suction Pipe-D Suction Pipe-E Accumulator Suction Pipe-B Motor Fixture Solenoid Way Vaive Outlet Pipe (Cond. ) Assy Outlet Pipe (Cond. )-B Outlet Pipe (Cond. )-A Way Valve Band Locking Spacer Cover Gasket Capillary Assy Transformer Thermostat-Outdoor Inlet Pipe (Cond. ) Assy Locking Spacer-B Bracket (Thermistor) Center Plate Accumulator Support Assy Terminal Gasket Washer Belt-Heater Terminal-5P Fuse Holder Fuse Accumulator Holder Rubber Discharge Temp. Thermistor Strainer-A
57 AOY30AMBH AOY30AMBL AOY30RMBL AOG30AMBH AOY30AMBL AOY30RMBL OUTDOOR UNIT Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. AOG30AMBH AOG30AMBL AOG30RMBL AOY30AMBH AOY30AMBL AOY30RMBL Ord. Q'ty 2 Fan Cover (Guard) Emblem-Rear Cabinet-A, Painted Cabinet-B, Painted Base Assy, Painted Way Valve (5/8) Packed Valve (3/8) Dryer Condenser Assy Inlet Pipe (Condenser) Outlet Pipe (Condenser) Discharge Pipe Compressor Cover Separate Wall Control Box Metal Capacitor (Fan Motor) Running Capacitor Capacitor Clamp Propeller Fan Fan Motor Assy-Out Motor Bracket-A Motor Bracket-B Motor Bracket-C Motor Bracket-D Compressor Assy Rubber (Discharge Pipe) Flange Nut Condensing Pipe Condensing Pipe-A Special Nut M Suction Pipe Assy Thermal Switch Cabinet Left, Painted Strap Check Joint Check Joint Bracket Valve Cover Valve Fixing Plate Rubber Mount Terminal Cover Terminal Cover Hex. Nut w/sp. Washer Clamp No Power Relay Thermistor (Heat Exchager) Controller PCB Assy Rubber Washer Muffler Accumulator Comp. Plate Assy Inlet Pipe (Cond. )-B Assy Solenoid Way Vaive Grip Clamp (Cable) No Holder Packing Terminal Gasket Capillary Assy Discharge Pipe Assy Transformer Bellmouth Protection Net Thermostat-Outdoor Thermistor (Out Temp. ) EMI Filter Bolt (Fan Motor Fixing) Cabinet Top Plate Panel Distributor Assy Clamp (Condenser) Joint Pipe-A Assy Joint Pipe-A Joint Pipe (Valve) Joint Pipe (Valve)-B Inlet Pipe (Accumulator)
58 AOY30AMBH AOY30AMBL AOY30RMBL AOG30AMBH AOY30AMBL AOY30RMBL OUTDOOR UNIT (Continued) Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. AOG30AMBH AOG30AMBL AOG30RMBL AOY30AMBH AOY30AMBL AOY30RMBL Ord. Q'ty Terminal-8P Fuse Holder Fuse Relay Accumulator Holder Rubber Thermistor (Discharge) Strainer-B Thermostat Cover Cord Clamp-A Cord Clamp-B
59 AOT25ANAL AOT25RZDL AOT25RNAL OUTDOOR UNIT Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. Ord. AOT25ANAL AOT25RZDL AOT25RNAL Q'ty 2 Fan Cover Emblem-Rear "FUJITSU" Cabinet-A, Painted Connector Cover (Panel, Top) Cabinet-B, Painted Base Assy, Painted Packed Valve (5/8) Packed Valve (3/8) Dryer Assy Condenser Assy U-Pipe (Y) Suction Pipe-A Suction Pipe Discharge Pipe Discharge Pipe-B Discharge Pipe-B Compressor Cover-A Separate Wall Control Box Metal Capacitor (Fan Motor) Running Capacitor Capacitor Clamp Metal Propeller Fan Fan Motor Assy-Out Motor Bracket Motor Bracket-B Motor Bracket-C Motor Bracket-D Compressor Assy Rubber (Discharge Pipe) Special Nut M5 (For Comp. ) Special Nut M8 (For Comp. ) Cabinet-Left, Painted Bolt, Hex. Socket Soft Starter Valve Cover Valve Fixing Plate Rubber Seat-A (For Comp. ) Terminal Cover (For Comp. ) Hex. Nut w/sp. Washer Rubber (Discharge Pipe) (Counter Weight) Capacitor (Start) Capillary Holder Rubber Clamp No Main Relay Power Relay Power Transformer Controller PCB Assy Muffler Comp. Plate Assy Suction Pipe-C Cond. Inlet Pipe Assy Accumulator Suction Pipe-B Suction Pipe-D Solenoid Coil Way Vaive Outlet Pipe Assy Capillary (Coil) Thermistor (Heat-Ex. ) Switch Bracket Accumulator Support Assy Locking Spacer Cover Gasket Capillary Assy Bellmouth Protection Net (Condenser) Thermostat-Outdoor Inlet Pipe (Cond. ) Assy Spacer EMI Filter EMI Filter Compressor Cover-B Thermostat Holder Pipe
60 AOT25ANAL AOT25RZDL AOT25RNAL OUTDOOR UNIT (Continued) Ref. No. Description When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Part No. AOT25ANAL AOT25RZDL AOT25RNAL Ord. Q'ty 678 Bracket (Thermistor) Cabinet Top Plate, Painted Clamp (Condenser) Terminal Gasket Washer (For Comp Thermistor (Discharge) Belt Heater Inlet Pipe (Accumulator) Terminal-5P Thermostat Fixture Joint Pipe (Valve) Fuse Holder Fuse Condensing Pipe-B Inlet Pipe (Accumulator)-B Accumulator Holder Rubber Network Strainer-A Thermostat Cover Cord Clamp-A Cord Clamp-B
61 AOT30AMBL AOT30RMBL OUTDOOR UNIT When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Ref. No. Description AOT30AMBL Part No. AOT30RMBL Ord. Q'ty Ref. No. Description AOT30AMBL Part No. AOT30RMBL Ord. Q'ty 2 Fan Cover Capacitor (Start) Emblem-Rear "FUJITSU" Clamp No Cabinet-A, Painted Power Relay Cabinet-B, Painted Thermistor (Heat Exchager) Base Assy, Painted Controller PCB Assy Way Valve (5/8) Muffler Packed Valve (3/8) Accumulator Dryer Comp. Plate Assy Condenser Assy Inlet Pipe (Cond. )-B Assy Inlet Pipe (Condenser) Solenoid Outlet Pipe (Condenser) Way Vaive Discharge Pipe Grip Compressor Cover Clamp (Cable) No Separate Wall Terminal Gasket Control Box Metal Capillary Assy Capacitor (Fan Motor) Discharge Pipe Assy Running Capacitor Transformer Capacitor Clamp Bellmouth Capacitor Clamp Protection Net Propeller Fan Thermostat-Outdoor Fan Motor Assy-Out Thermistor (Out Temp. ) Motor Bracket-A EMI Filter Motor Bracket-B Bolt (Fan Motor Fixing) Motor Bracket-C Cabinet Top Plate Panel Motor Bracket-D Distributor Assy Compressor Assy Clamp (Condenser) Rubber (Discharge Pipe) Joint Pipe-A Condensing Pipe Joint Pipe (Valve) Condensing Pipe-A Joint Pipe (Valve)-B Special Nut M Inlet Pipe (Accumulator) Suction Pipe Assy Terminal-8P Cabinet Left, Painted Thermostat Fixture Soft Starter Fuse Holder Strap Fuse Check Joint Relay Check Joint Bracket Accumulator Holder Rubber Valve Cover Thermistor (Discharge) Valve Fixing Plate Strainer-B Rubber Mount Thermostat Cover Terminal Cover Cord Clamp-A Hex. Nut w/sp. Washer Cord Clamp-B
62 STANDARD ACCESSORIES INDOOR UNIT ACCESSORIES Name and Shape Q`ty Application AR ALC AR RLC Installation template 1 For positioning the indoor unit Hanger 4 For suspending the indoor unit from ceiling Special nut A (large flange) 4 For suspending the indoor unit from ceiling Special nut B (small flange) Coupler heat insulation (large) 2 For indoor side pipe joint (large pipe) Coupler heat insulation (small) 1 For indoor side pipe joint (small pipe) Nylon fastener 1 For fixing the drain hose Remote control unit (ART model) (ART model) Remote control unit cord clamp 10 For installing the remote control unit cord Tapping screw (flush heads) 10 For installing the remote control unit cord clamp Auxiliary pipe assembly 1 For wiring conduit (gas side) connection Drain hose insulation 1 Insulates the drain hose and vinyl hose connection Remote sensor kit 1 For measuring the indoor temperature (refer to the remote sensor installtion manual.)
63 0305G2272
DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationCEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY0ELA AOY0EPBL CONTENTS SPECIFICATIONS.............................. OUTLINE AND DIMENSIONS...................... CIRCUIT DIAGRAM............................
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationFLOOR CONSOLE / UNDER CEILING DUAL type
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25ALC-W AUG25ALQ-W AUG25RLC-W AUG30ALC-W AUG30ALQ-W AUG30RLC-W AOG25AZCL AOG25AZQL AOG25RZCL AOG30ABML AOG30ABSL AOG30RBML
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationFLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationCASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.
SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationWALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )
SPLIT T YPE ROOM AIR CONDITIONER WALL MOUNTE type Models Outdoor Unit Serial No. Starting with T000001 ( Compressor Recipro type ) Indoor unit ASU18C1 ASU18R1 ASU24C1 ASU24R1 ASU30C1 Outdoor unit AOU18C1
More informationASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT
WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................
More informationASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM
More informationAUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit AUXG8LRL AUXGLRL UTG-UKYA-W Outdoor unit AOYG8LCA AOYGLCA CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT
More informationC E IL IN G W A L L SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE ROOM AIR CONDITIONER C E IL IN G W A L L t y pe Models Indoor unit Outdoor unit AWY24LBAJ AOY24LMAL AOY30LMAL CONTENTS SPECIFICATIONS................................ 1 OUTLINE AND DIMENSIONS..........................
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationParts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1100MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71392 Issued: 12-12-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationCU1526, CU2026, CU3030 Service Parts
This is the illustrated list of service parts for all models of the CU, CU0 and CU00 self contained ice machines. These machines were manufactured in several voltages, which is designated by a numeric
More informationParts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationParts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-340MAJ, MWJ hoshizakiamerica.com Number: 71389 Issued: 10-23-2017 Revised: 6-12-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationParts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-515MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71390 Issued: 10-23-2017 Revised: 11-17-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Commercial Series Refrigerated Kitchen Equipment Models CRA-FS CRA-HS CFA-FS CFA-HS A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71309 Issued: 7-1-011 CONTENTS
More informationCMS1402 SERVICE PARTS
This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Rev 8/08 # This parts
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationSERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications
CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Block Diagrams
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606
MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50HZ units Mile High Equipment 11100 East 45th Ave Denver, Colorado 80239 Print Date 03/03 * This parts list contains
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-500MAJ KML-500MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-500MAJ KML-500MWJ hoshizakiamerica.com Number: 71378 Issued: -8-017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-325MAJ KML-325MWJ hoshizakiamerica.com Number: 71377 Issued: 4-7-2017 Revised: 9-8-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationSERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS
SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationSERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305
SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More informationCME1056 Service Parts. Table of Contents
This is the parts list for the CME0 ice machine. The CME0 was manufactured in A, D, E and F series, as well as single phase 0 Hz, single phase 0 Hz, and three phase. The E series change was to side panels
More informationNM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...
This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS
More informationWater Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL
Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationFor more Parts Information: https://manitowocfsg.sysonline.com/default.aspx
For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
-(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3
More informationAFE400 SERVICE PARTS
This is the parts list for the AFE00. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationMobile Type Air Conditioner
Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following
More informationSERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications
SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the
More informationGlobal-Tek (Singapore) Pte Ltd
Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10
More informationSERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2
Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models
More informationCABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)
CABINET PARTS 48" BUILT IN REFRIGERATOR 10 02 Litho In U.S.A. (mek) 1 Part No. 1 LITERATURE PARTS LIT2209249 Use & Care Guide LIT2006651 Energy Label LIT2006748 Service & Wiring Sheet LIT628370 Modular
More informationNM1850 SERVICE PARTS
This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS
More informationCME650 SERVICE PARTS
This section contains the parts illustrations and parts lists for the CME650. CM650 ice machines are manufactured in both 60 cycle and 50 cycle. When ordering electrical parts, be certain to match the
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationCASSETTE TYPE AIR CONDITIONER
CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....
More informationParts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH hoshizakiamerica.com Number: 71357 Issued: 11-19-2014 Revised: 11-28-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationKSSS42QDW05, KSSS42QDX05
CABINET PARTS 42" BUILT IN REFRIGERATOR 4 97 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Cabinet (Not A Serviceable Part) 3 2005004 Grommet, Tube Crossover 4 1112023 Roller, Front & Rear (4) 5 Support,
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationCU0415, CU0715 and CU0920 Service Parts
CU0, CU0 and CU00 Service Parts This is the illustrated parts list for the CU0, CU0 and CU00. The CUR0, CUR0 and CUR00 are - (0-0/0/) versions of the matching models. There are voltages, /0/, 0-0/0/ and
More informationRANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.
BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationCABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)
CABINET PARTS 42" BUILT IN REFRIGERATOR 1 08 Litho In U.S.A. (mat) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10151251 Use & Care Guide W10164079 Energy Guide W10159831 Service & Wiring Sheet
More information6868 Ardmore Street Houston, Texas Toll Free Phone Fax
P-09 P-09 P-09A COMPONENT PART NO. COMPONENT PART NO. BASE PAN 67904000 AIR OUTTAKE 67809008 OUTDOOR CENTRIFUGAL FAN 67809032 TURNING WHEEL (CASTER) 67904001 (4) ERECT LOUVER ASSY 67809006 (5) OUTDOOR
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationService Parts for models UF424 and UN324
Service Parts for models UF and UN This is the illustrated parts list for Scotsman ice maker models UF and UF. They were manufactured as either air or water cooled models, plus the air cooled models were
More informationParts List. Modular Flaker. Models FD-1002MAJ-C, MRJ-C. hoshizakiamerica.com
Parts List Modular Flaker Models FD-1002MAJ-C, MRJ-C hoshizakiamerica.com Number: 71372 Issued: 8-14-2017 CONTENTS Note About Ordering Parts... 3 A. Main Assembly & Refrigeration Circuit... 4 FD-1002MAJ-C...
More information6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)
6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1
More informationParts List. Modular Flaker F-1501MAH(-C) F-1501MWH(-C) F-1501MRH(-C) hoshizakiamerica.com
Parts List Modular Flaker F-1501MAH(-C) F-1501MWH(-C) F-1501MRH(-C) hoshizakiamerica.com Number: 71353 Issued: 7-9-2014 Revised: 12-14-2017 CONTENTS Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationTABLE OF CONTENTS. Air Conditioner
Order No. MAC0804027A2 Air Conditioner CS-E9GFEW-2 CU-E9GFE-2 CS-E12GFEW-2 CU-E12GFE-2 CS-E18GFEW-2 CU-E18GFE-2 CU-2E15GBE CU-3E18EBE CU-3E23CBPG CU-4E27CBPG Please file and use this manual together with
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-2500SWH3 KM-2500SRH3 A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71281 Issued: 9-3-2009 Revised:10-8-2014 CONTENTS Auxiliary
More informationEXPLODED VIEWS & PARTS LISTS
542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationSERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC
Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationCABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)
CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 4 12 Litho In U.S.A. (mlg)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303987 Use & Care Guide W10205624 Energy Guide W10483322 Service
More informationMDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6
This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing parts to be sure that this is the correct parts list. There have been several
More informationCABINET PARTS For Model: KSSC42QVS03 (Stainless Steel)
CABINET PARTS 42" BUILT IN REFRIGERATOR 2 12 Litho In U.S.A. (wlc)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303989 Use & Care Guide W10205643 Energy Guide W10159832 Service & Wiring Sheet
More informationFM1500 SERVICE PARTS
This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing the parts to be certain that this is the correct parts list. FM00 SERVICE PARTS
More informationSERVICE Manual FREE JOINT MULTI AIR CONDITIONER
FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4
More informationSERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1
SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED
More informationMUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service
More informationSIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel)
SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel) 03/21/2018 2018 Whirlpool Corporation Part No. W11157383 Rev. B
More informationFor more Parts Information:
For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series
More information6. DUCT TYPE AR 60FUAK, AR 60UUAK
R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081307-01 Rev 3/06 * This parts list contains
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationSERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation
ROOM AIR CONDITIONER AW079 AW089 SERVICE Manual AIR CONDITIONER CONTENTS. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationCommercial Refrigerator & Freezer Service Manual
Commercial Refrigerator & Freezer Service Manual Sandwich Salad Unit Under counter Refrigerator & Freezer Model No.: TUR-28SD TUR-48SD TST-28SD TST-48SD TUF-28SD TUF-48SD TABLE OF CONTENTS. FEATURE CHART
More informationItem RED=NLA-NR=No Longer Available-No Replacement Code Part Description Part Number GRP
5.0 CUBERS C136-C186 "B" SERIES AIR, WATER AND REMOTE Code Part Description Part Number GRP 136 186 AIR COOLED 5 Air Condenser 9141064-01 AC X 10 Fan Blade 10" 9131053-01 AC X 15 Fan Motor 35 watt 9161124-03
More information