Evaporative Cooling Applicability in the Middle East
|
|
- Camilla Moore
- 6 years ago
- Views:
Transcription
1 Evaporative Cooling Applicability in the Middle East Oxycom Fresh Air BV April 14th, 215 Abstract Oxycom developed various evaporative cooling solutions, either as standalone configurations or as combinations of technologies, to cover the entire climate of the Middle East. Standalone Oxyvap direct evaporative cooling is preferred in areas having low absolute humidity, twostage Oxyvap or standalone Oxycell indirect evaporative cooling in areas having low to moderate absolute humidity and Oxyvap-based condenser pre-cooling or Oxycellbased hybrid cooling in areas having low to high absolute humidity. 1 Introduction 1.1 Company overview Oxycom is a Dutch company specialized in the development and production of products and components for adiabatic cooling, indirect evaporative cooling, dew point cooling, air humidification and heat recovery. Oxycom developed, engineered and manufactures the Oxycell Indirect Evaporative Heat Exchanger and the Oxyvap Direct Evaporative Cooling pad. The Oxycell is the base of highly efficient all season fresh air systems that provide dew point cooling, indirect evaporative cooling, heat recovery and ventilation. The Oxyvap is the base of highly efficient cooling-only systems that provide direct evaporative cooling, humidification and ventilation. 1.2 Scope of the paper The Middle East consumes large amounts of electrical energy to power conventional vapor compression air conditioning systems for residential, commercial and industrial purposes, mainly originating from fossil fuels [1]. Oxycom uses water instead, one of nature s most powerful refrigerants (R718) [2], to cool air in an environmentally friendly matter. Evaporating water at a rate of 1 L/h generates 695 W of cooling power [3], whereas conventional air conditioning systems typically require as much as 25 3 W of electrical power to achieve the same [4]. Desalination of water at at rate of 1 L/h typically requires only 4 W of electrical power [5]. This paper shows the applicability of Oxycom s evaporative cooling technologies and technology combinations, based on outdoor air conditions in a range of major cities throughout the Middle East. 2 Technology overview 2.1 Introduction Oxycom developed several evaporative cooling technologies and technology combinations, each with its own applicability region. Standalone Oxyvap: suitable for any outdoor temperature and outdoor absolute humidity up to 12 g/kg. Two-stage Oxyvap: suitable for any outdoor temperature and outdoor absolute humidity up to 16 g/kg. Standalone Oxycell: suitable for any outdoor temperature and outdoor absolute humidity up to 16 g/kg. Oxycom Fresh Air BV - P.O. Box 212, NL-81 AE Raalte - Phone: +31() info@oxy-com.com 1
2 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East Oxycell-based hybrid cooling: suitable for any outdoor temperature and humidity. Oxyvap-driven condenser pre-cooling: suitable for any outdoor temperature and humidity. 2.2 Standalone Oxyvap The upper half of the supply air will have a higher enthalpy than the intake air, whereas the lower half will have a lower enthalpy. When the upper half of the air is discarded, the lower half can be used as supply air, reaching an average temperature below the initial wet bulb temperature, while less moisture is added compared to traditional adiabatic cooling. 2.4 Standalone Oxycell The Oxyvap is a direct evaporative cooling pad, that adiabatically cools air towards its wet bulb temperature, typically achieving a 9% saturation efficiency. Its modular design enables it to be used for any airflow, while the frontal air velocity is typically 1 3 m/s. 2.3 Two-stage Oxyvap The Oxycell is a counter-flow indirect evaporative heat exchanger in which air in the secondary channel (work air) is adiabatically cooled and humidified, hereby extracting heat from air in the primary channel (process air). This principle is referred to as Indirect Evaporative Cooling (IEC). The two-stage Oxyvap is an Oxyvap-based cooling configuration, that uses an additional air-to-water heat exchanger to enhance its performance. Chilled water from the Oxyvap is fed to the heat exchanger to pre-cool outdoor air before it enters the Oxyvap pad, that is then fed with water returning from the heat exchanger. Since it is a closed system, the cooling process as a whole will be adiabatic, but the combination of the precooling process and the recirculation of water between the components will lead to a vertical temperature gradient in the air leaving the Oxyvap pad. Dew Point Cooling (DPC) is a special application of the Oxycell IEC principle, in which part of the cooled primary outlet air (typically 35 4%) is branched off and used as secondary inlet air, where it is cooled adiabatically, hereby extracting heat from the primary air stream. Ideally, primary air can be cooled down to its dew point temperature, while maintaining a constant absolute humidity. Whether DPC or IEC is the preferred cooling method depends on various parameters, such as the outdoor air conditions, heat load and fan configuration. 2
3 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 2.5 Oxycell-based hybrid cooling consequently increasing its efficiency. 3 Climate data The hybrid configuration is based on the Oxycell IEC principle. In practice, the Oxycell IEC cools outdoor air (flowing through the primary channel) down to about a degree above the physical limit, i.e. the wet bulb temperature of the secondary inlet air, while maintaining a constant absolute humidity. When humid outdoor air conditions do not allow for sufficient cooling from the Oxycell itself, the evaporator coil from a conventional vapor compression air conditioning system may be used to cool and dehumidify precooled air from the Oxycell to the desired supply air conditions. The condenser coil is placed downstream of the secondary (wet) channel of the Oxycell. Generally, this air is cooler than the outdoor air, leading to an increase in compressor efficiency. Annual savings are typically 5% compared to existing standalone conventional air conditioning systems. 2.6 Oxyvap-based condenser pre-cooling 3.1 Introduction Typically, throughout the Middle East, the outdoor temperature can exceed 4 C or even 5 C for a substantial amount of hours per year. The absolute humidity, on the other hand, depends strongly on the geographical position. Rather than the temperature, evaporative cooling performance is mainly determined by the absolute humidity. To illustrate the applicability of Oxycom s evaporative cooling technologies and technology combinations in the Middle East, 35 major cities in 15 countries have been selected, of which hourly climate data between 27 and 214 has been analysed [6]. The graphs below show per city which absolute humidity values occur during a year, divided in 2 g/kg intervals. A distinction into absolute humidity categories has been made based on the highest absolute humidity that occurs, with the exception of the 175 most humid hours, such that it covers 98% of the year, in accordance with ASHRAE climatic design guidelines [7]. Absolute humidity categories: Low: up to 12 g/kg. Low to moderate: up to 16 g/kg. Low to high: to above 16 g/kg. 3.2 Low absolute humidity Shiraz (Iran) In conventional air conditioning technology, a compressor is used to compress the gaseous coolant before it loses its heat by condensation in the condenser coil. When using the Oxyvap to pre-cool the outdoor air that is supplied to the condenser coil, the coolant is able to condense at a lower temperature, hereby decreasing the work that has to be done by the compressor and
4 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East Tabuk (Saudi Arabia) Mashhad (Iran) Ankara (Turkey) Tehran (Iran) Tabriz (Iran) Sana'a (Yemen)
5 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East Riyadh (Saudi Arabia) Medina (Saudi Arabia) Baghdad (Iraq) Aswan (Egypt) Amman (Jordan) Gaziantep (Turkey)
6 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 3.3 Low to moderate absolute humidity Mosul (Iraq) Izmir (Turkey) Basrah (Iraq) Luxor (Egypt) Kuwait City (Kuwait) Istanbul (Turkey)
7 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 3.4 Low to high absolute humidity Baku (Azerbaijan) Nicosia (Cyprus) Alexandria (Egypt) Cairo (Egypt) Dammam (Saudi Arabia) Beirut (Lebanon)
8 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East Antalya (Turkey) Mecca (Saudi Arabia) Salalah (Oman) Al Ain (United Arab Emirates) Jeddah (Saudi Arabia) Manama (Bahrein)
9 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East Abu Dhabi (United Arab Emirates) Muscat (Oman) Dubai (United Arab Emirates) Doha (Qatar) Applicability 4.1 Introduction The outdoor absolute humidity classification determines the preferred technology or combination of technologies. Low: standalone Oxyvap. Low to moderate: two-stage Oxyvap or standalone Oxycell. Low to high: Oxyvap-based condenser pre-cooling or Oxycell-based hybrid cooling. 9
10 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 4.2 Low absolute humidity Ankara Gaziantep Tabriz Tehran Mashhad Amman Baghdad Tabuk Shiraz Aswan Medina Riyadh Sana'a 1
11 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 4.3 Low to moderate absolute humidity Istanbul Izmir Mosul Basrah Luxor Kuwait City 11
12 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East 4.4 Low to high absolute humidity Antalya Baku Nicosia Beirut Alexandria Cairo Dammam Jeddah Mecca Manama Doha Abu Dhabi Dubai Al Ain Muscat Salalah 5 Summary Category of outdoor Number of Geographical Preferred Alternative absolute humidity cities* location technology technology Low 13 Desert or arid Standalone Oxyvap Condenser pre-cooling desertlike inland or two-stage Oxyvap or standalone Oxycell Low to moderate 6 Mainly between Two-stage Oxyvap Condenser pre-cooling coast and inland or standalone Oxycell Low to high 16 Mainly coastal Condenser pre-cooling or hybrid cooling *Out of a total of 35 analysed cities in the Middle East. 12
13 (XRD-Q-7-2) Evaporative Cooling Applicability in the Middle East References [1] Glada Lahn, Paul Stevens and Felix Preston, Chatham House, the Royal Institute of International Affairs, Saving Oil and Gas in the Gulf (213). [2] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 29 ASHRAE Handbook Fundamentals (SI), Chapter 29 Refrigerants (29). [3] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 29 ASHRAE Handbook Fundamentals (SI), Chapter 1 Psychrometrics (29). [4] SKM Air Conditioning Equipment, PACX Series Packaged Air Conditioners (Range 6 TR to 5 TR), Refrigerant - R134a, Bulletin # 51/27 (27). [5] DESWARE, Encyclopedia of Desalination and Water Resources, Energy Requirements of Desalination Processes, [6] The Weather Channel, LLC, Weather Underground, [7] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 29 ASHRAE Handbook Fundamentals (SI), Chapter 14 Climatic Design Information (29). 13
Oxyvap Evaporative Cooling Applications
Oxyvap Evaporative Cooling Applications Oxycom Fresh Air BV March 9th, 2015 Abstract This paper shows two highly efficient applications of the Oxyvap direct evaporative cooling technology, developed by
More informationME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes
ME 410 - Mechanical Engineering Systems Laboratory Experiment 3 - Mass and Energy Balances in Psychrometric Processes Assist.Prof.Dr. Özgür BAYER, A-123 AIR-CONDITIONING (A/C) Goal: Control temperature
More informationConcrete Cooling Systems
Worldwide # 1 in Concrete Cooling More than 25 years of experience Concrete Cooling Systems Ice Water and Cold Water Plants Containerized Ice Water Plant CIWP.4 (4th Generation) m³/h 45 C Ice Water and
More informationFeasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to
More informationChapter 14, Problem 27.
Chapter 14, Problem 27. A house contains air at 25 C and 65 percent relative humidity. Will any moisture condense on the inner surfaces of the windows when the temperature of the window drops to 10 C?
More informationYOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE
YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE ENERGY INTERNATIONAL CORPORATION CORPORATE PROFILE For more than 30 years, Energy International Corporation (EIC) has been a
More informationPthey are comfortable. In regions with hot
Enhancing people comfort and process efficiency eople are happier and more productive when Pthey are comfortable. In regions with hot weather, cooling spaces where people live and work is becoming the
More informationTechnical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:
Refrigeration Systems Theoretical hours: 2 Practical hours: 2 Units: 6 COOLING TOWERS First 10 minutes: review the last lecture. Then explain the new lecture, solve an example. Last 10 minutes review the
More informationTECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1
TECHNICAL NOTE ON EVAPORATIVE COOLING Renato Lazzarin, President of the IIR s Commission E1 Principles The air has a variable water content from 0 (dry air) to a maximum value (saturated air) that strongly
More informationSection 4 of 6 DOAS Core Technologies
Section 4 of 6 DOAS Core Technologies Desiccant dehumidification Air-to-air energy recovery Evaporative cooling 1 Desiccant dehumidification Industrial Desiccant Dehumidifier Hybrid DX + Desiccant Dehumidifier
More informationChapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING
Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008 Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Mehmet Kanoglu Copyright The McGraw-Hill Companies,
More informationEXPERIMENTAL STUDY OF WATER DESALINATION BASED ON HUMIDIFICATION- DEHUMIDIFICATION PROCESS VIA HEAT PUMP
EXPERIMENTAL STUDY OF WATER DESALINATION BASED ON HUMIDIFICATION- DEHUMIDIFICATION PROCESS VIA HEAT PUMP A. E. Tourab 1, Mohamed A. Teamah 2, Ahmed A. Hanafy 1, Wael M. EL-Maghlany 2 1 Arab Academy for
More informationAND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University
Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate
More informationWeek 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1
Week 4 Gas-vapor mixtures Air conditioning processes ME 300 Thermodynamics II 1 Today s Outline Gas-vapor mixtures Key definitions and measures ME 300 Thermodynamics II 2 Gas-vapor Mixtures At temperatures
More informationControl Technologies Fze Ph: E: Sharjah, UAE. M: W:
Company Profile 1 2 3 4 5 6 7 Control Technologies Fze (Ctrltech) founded in 2008. It is based at Sharjah Airport Free Zone, Sharjah. We provide our services to all Emirates i.e. Dubai, Sharjah, Abu Dhabi,
More informationCE311 Fall 2016 Mid-Term Exam 1
CE311 Fall 16 Mid-Term Exam 1 Name Instructions 1. Please solve the problems using the specified SI or IP system of units. 2. Please show all of your calculations to get full credit and pay attention to
More informationImpact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System
4 th International Conference On Building Energy Environment Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System J Y Park H W
More informationTwo Stage Indirect/Direct Evaporative Cooling
Two Stage Indirect/Direct Evaporative Cooling Abstract The performance of two-stage indirect/direct evaporative cooling system is experimentally investigated. For this purpose, a two-stage evaporative
More informationAir Conditioning System with Modified Condenser Ducts and Evaporative Cooling
Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling Dr. Akash Langde 1, Zeeshan Jamal 2, Shahrukh Jamal 3, Mohammad Shumoil Ansari 4 1Professor, Department of Mechanical Engineering,
More informationVISION MISSION. To be internationaly renowned customer focused company offering comprehensive solutions and quality products
MESSAGE Over the last few years, JGB has been continually evolving to position itself as a leading supplier of various engineered products in the region. These are indeed exciting times for the company,
More informationINDIRECT EVAPORATIVE COOLING A PAST REVIEW
Int. J. Mech. Eng. & Rob. Res. 2013 Kant G Hirde and C R Patil, 2013 Review Article ISSN 2278 0149 www.ijmerr.com Vol. 2, No. 2, April 2013 2013 IJMERR. All Rights Reserved INDIRECT EVAPORATIVE COOLING
More informationMETHODS FOR ANALYZING THE ENERGY EFFICIENCY AND COST EFFECTIVENESS OF EVAPORATIVE COOLING AIR CONDITIONING
METHODS FOR ANALYZING THE ENERGY EFFICIENCY AND COST EFFECTIVENESS OF EVAPORATIVE COOLING AIR CONDITIONING A. Fouda 1, Z. MELIKYAN 2 1 Department of mechanical power engineering, Faculty of engineering,
More informationThermodynamics II Chapter 6 Mixtures & Psychrometry
Thermodynamics II Chapter 6 Mixtures & Psychrometry Mohsin Mohd Sies Fakulti Kejuruteraan Mekanikal, Universiti Teknologi Malaysia Objectives Differentiate between dry air and atmospheric air. Define and
More informationCE311 Fall 2016 Mid-Term Exam 1
Instructions 1.! Please solve the problems using the specified SI or IP system of units. 2.! Please show all of your calculations to get full credit and pay attention to assumptions. 3.! Neatly mark points
More informationME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3
ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes
More informationEvaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study
www.amec.com Evaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study DISCUSSION TOPICS Brief Overview of Air-Cooled and Evaporative-Cooled Condenser Technologies Pros and Cons Scope and Results
More informationReducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling
Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of
More informationENGINEERING AND CONSTRUCTION BULLETIN
ENGINEERING AND CONSTRUCTION BULLETIN No. 2016-15 Issuing Office: CECW-CE Issued: 23 May 16 Expires: 23 May 18 CATEGORY: Guidance 1. References: Jesse Dean, Lesley Herrmann, Eric Kozubal, and Jesse Geiger
More informationIntrCooll. Cool large buildings at 80% lower running costs
IntrCooll Cool large buildings at 80% lower running costs IntrCooll INDIRECT/DIRECT ADIABATIC COOLING COOLING CAPACITY UP TO 134 kw (38 TR) UP TO 116% WET-BULB EFFICIENCY EER UP TO 44 (150 BTU/Wh) Introduction
More informationArticle Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms
Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms Min Suk Jo, Jang Hoon Shin, Won Jun Kim and Jae Weon Jeong * Department of Architectural
More informationICE PLANTS CHILLERS AGGREGATES COOLING
COOLING SYSTEMS ICE PLANTS CHILLERS AGGREGATES COOLING COOLING SYSTEMS SCS EQUIPMENT COOLING SYSTEMS ICE & ICE WATER PLANTS Guaranteed 30-50 % energy savings compared to a conventional ice system due to
More informationHistoric and classic colours. An exclusive collection
Historic and classic colours An exclusive Historic and classic colours Hempel has been a world leading coatings supplier since 1915 for the decorative, protective, marine, container and yacht markets.
More information10.17 Scope of Accreditation
Inspection Body Accreditation is accredited by the GCC Accreditation Center () in accordance with the recognized International Standard, Conformity assessment requirements for the operation of various
More informationHVAC (Heating, Ventilating, and Air Conditioning)
HVAC (Heating, Ventilating, and Air Conditioning) Gas vapor Mixtures The term vapor implies a gaseous state that is close to the saturation region of the substance, raising the possibility of condensation
More informations. Properties for R134a are as follows : Saturated R-134a Superheated R-134a
CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.
More informationAir Conditioning and process cooling Energy Components at a Glance
Energy Components at a Glance What is it? A means of providing cooling with mechanical refrigeration equipment. Where is it found? Chilled water is found in many plants, non-existent in others. Essential
More informationCMES International Contacts
CMES International Contacts CMES has a network of contacts, which can be helpful for student s setting up their 3 rd semester internship or research projects. Contacts can be said to be; official contacts;
More informationTHE RISKS TO CULTURAL HERITAGE IN
Perfil HEM140 500 mm 1 300 mm 150 mm 60 mm 30 mm 300 mm THE RISKS TO CULTURAL HERITAGE IN WESTERN AND CENTRAL ASIA University of Isfahan, Isfahan, Iran m.hejazi@eng.ui.ac.ir University of Minho Czech Technical
More informationPERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE
Journal of Sustainability Science and Management Volume 9 Number 1, June 2014: 150-155 ISSN: 1823-8556 Penerbit UMT PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE ARFIDIAN
More informationPERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.329 341, Article ID: IJMET_07_03_030 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3
More informationHeat pump and energy recovery systems
SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air
More informationHassan Dennaoui, PhDc, ME, MSc
Hassan Dennaoui, PhDc, ME, MSc ECONOMIC ZONES ADVISOR/UNIVERSITY LECTURER Name of Current Employer Profession Tripoli Special Economic Zone Director/Engineer/Consultant/University Lecturer Age 37 Years
More informationComparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area
Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area MMS DEZFOULI, SOHIF MAT, K.SOPIAN Solar Energy Research Institute (SERI, Universiti
More informationOptimize Evaporative Cooler
Frequently Asked Questions and Answers Contents regarding the Optimize Evaporative Cooler Technical 1 General Questions, Cooling Potential and Cooling Efficiency 2 Air velocity and pressure loss 3 Erection
More informationEVAPORATIVE AIR-COOLING EQUIPMENT
T CHAPTER 41 EVAPORATIVE AIR-COOLING EQUIPMENT Direct Evaporative Air Coolers... 41.1 Indirect Evaporative Air Coolers... 41.3 Indirect/Direct Combinations... 41.5 Air Washers... 41.6 Humidification/Dehumidification...
More informationImpact of indirect evaporative air cooler type on the performance of desiccant systems
Impact of indirect evaporative air cooler type on the performance of desiccant systems Anna Pacak 1,*, Aleksandra Cichoń 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of Science and
More information10.6 Schedule of Accreditation
Accreditation Manager: Product Certification Body Accreditation is accredited by the GCC Accreditation Center () in accordance with the recognized International Standard, Conformity assessment -- Requirements
More informationANALYSIS OF VAPOUR COMPRESSION REFRIGERATION (VCR) BASED AIR CONDITIONING (AC) SYSTEM FOR HOT AND DRY CLIMATIC CONDITIONS IN OMAN
Journal of Thermal Engineering, Vol. 4, No. 3, pp. 1926-1938, April, 2018 Yildiz Technical University Press, Istanbul, Turkey ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION (VCR) BASED AIR CONDITIONING (AC)
More informationArmstrong Cool-Fog Systems
Armstrong Cool-Fog Systems Armstrong International, Inc. is a leading supplier of hydropneumatic fogging systems used for both humidification and evaporative cooling. Its systems were first developed in
More informationINTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011
Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage Kulkarni.R.K 1, Rajput S.P.S 2 1 SVPM College of Engineering, Malegaon(bk),
More informationThermo-physical properties found on most psychrometric charts
Psychrometric Chart The psychrometric chart displays the relationship between dry-bulb, wet-bulb, and dew point temperatures and specific and relative humidity. Given any two properties, the others can
More informationME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY
ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes
More informationDynamic performance of a novel dew point air conditioning for the UK buildings
*Corresponding author: xudongzhao@nottingham. ac.uk Dynamic performance of a novel dew point air conditioning for the UK buildings... Xudong Zhao *, Zhiyin Duan, Changhong Zhan and Saffa B. Riffat School
More informationω = (1) Kirby S. Chapman Ph.D.
White Paper: Relative Humidity Impacts of the AirFloor System in the Built Environment Kirby S. Chapman Ph.D. kirby.chapman@scavengetech.com Introduction Relative humidity is specified as one of the seven
More informationEXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING
EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING Ayad T. Mustafa College of Engineering, Nahrain University, Jadiriya, Baghdad,
More informationTopic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline
ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces
More informationAn Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment
Technical Report An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Hironobu Kurara, Custom Equipment Engineering Department 2, Custom Equipment
More information... II.. s::. U II!.! 0 I Q I! n) ~}.St.ll ~I Jq~ (Jql.siLII U" I? o Jq~ GCC Standardization Organization. Designation of a Notified Body
... II.. s::. U II!.! 0 I Q I! n) ~}.St.ll ~I Jq~ (Jql.siLII U" I? o Jq~ GCC Standardization Organization Designation of a Notified Body The GCC Standardization Organization (GSO) hereby affirms that Bureau
More informationDesign and Development of Combined Direct and Indirect Evaporative Cooling System
ISSN 2395-1621 Design and Development of Combined Direct and Indirect Evaporative Cooling System #1 Pallavi B. Bedre, #2 H.U.Tiwari 1 pallavi.bedre@gmail.com 2 sharvay12 @rediffmail.com #12 Pimpri-Chinchwad
More informationSteel, Civil, MEP & Telecommunication Infrastructure Service Providers MEP Profile
Steel, Civil, MEP & Telecommunication Infrastructure Service Providers MEP Profile 1 Gulf Turrets Presence BAHRAIN QATAR U.A.E. - Dubai U.A.E. - Abu Dhabi OMAN ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS
ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering,
More informationANALYSIS OF THE MAISOTSENKO CYCLE BASED COOLING SYSTEM FOR ACCUMULATOR BATTERIES
International Journal of Energy for a Clean Environment, 12(2 4), 95 99 (2011) ANALYSIS OF THE MAISOTSENKO CYCLE BASED COOLING SYSTEM FOR ACCUMULATOR BATTERIES Manap Khazhmuradov, Dmitrij Fedorchenko,
More informationINTRODUCTION SALAM/ATELIER21
INTRODUCTION SALAM/ATELIER21 Established originally as an interior design, engineering, trading and fit-out firm, Salam/Atelier21 delivers personalized, luxury interior solutions and services to discerning
More informationPerformance Rating of Computer and Data Processing Room Air Conditioners
ANSI/AHRI Standard 1360 (I-P) with Addendum 1 2013 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners Approved by ANSI on November 8, 2013 WITH ADDENDUM 1, PERFORMANCE
More informationCO2 TRANSCRITICAL BOOSTER SYSTEMS
CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More informationAdconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h
Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro
More informationHumidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China
Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China Xiaoping Yu Doctoral Candidate Chongqing University of Science & Technology Chongqing, China, 400042 xiaoyup@163.com
More information: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE
COURSE TITLE : REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE MODULE TOPIC PERIODS 1 Introduction. Applications
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationBOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationDirect and indirect evaporative cooling
Using the evaporative process to precool the supply air stream can reduce the energy consumption of mechanical cooling equipment. Two methods of evaporative cooling exist: direct and indirect. The effectiveness
More informationTheoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates
INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 3, ISSUE 4, APRIL 214 ISSN 2277-8616 Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates Ibrahim U. Haruna,
More information2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)
2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment AHRI Guideline T (I-P) IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the
More informationComfort and health-indoor air quality
Comfort and health-indoor air quality 1 The human body has a complicated regulating system to maintain the human body temperature constant most of the time, which is 98.6 F (36.9 C) regardless of the environmental
More informationSWIMMING POOL SWIMMING POOL DEHUMIDIFICATION
SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics
More informationYOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS
YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS Energy International Corporation is the recognized leader in the distribution of HVAC and electromechanical products throughout the Middle East
More informationPDHonline Course A127 (4 PDH) Evaporative Cooling. Instructor: George E. Thomas, PE. PDH Online PDH Center
PDHonline Course A127 (4 PDH) Evaporative Cooling Instructor: George E. Thomas, PE 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org
More informationR134a. DCLC Series 50Hz. Water Cooled Centrifugal Chillers Cooling Capacity: 300 to 1500 TR (1055 to 5274 kw)
DCLC Series 50Hz Water Cooled Centrifugal Chillers Cooling Capacity: 300 to 1500 TR (1055 to 5274 kw) R134a Products that perform...by people who care 1.0 GENERAL For most of the 20 th Century, DB has
More informationDehumidification of Atmospheric Air for Water Production
Dehumidification of Atmospheric Air for Water Production Vinay M V 1, Suman A 2, Shadakshari R 3 U.G. Student, Department of Mechanical Engineering, Acharya Institute of Technology, Bangalore, Karnataka,
More informationEvaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling
Evaporative Cooling an alternative and supplement to mechanical cooling HEVAC Association Humidity Group 1. WHAT IS EVAPORATIVE COOLING? Evaporative Cooling is one of the oldest cooling systems known to
More informationFirst Use Safety Recommendation
SB22 Slender Blender First Use Safety Recommendation Please read through this booklet for safe and efficient use of the appliance. We urge you to read the "Important Safeguards" section and also follow
More informationExperimental Study of Direct Contact Condensation of Steam on Water Droplets
, July 1-3, 2015, London, U.K. Experimental Study of Direct Contact Condensation of Steam on Water Droplets Semra GUMRUK, Murat K. AKTAS Abstract Air or water cooled condensers are used to reduce the moisture
More informationAHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency
Application Note 24 AHRI 920 Performance Rating and Comparisons I NTRODUCTION In 2015, the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) introduced a performance rating for dedicated outside
More informationOpen Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations
43rd ANZSES Conference Solar 24, Denedin (NZ), 28.11.-3.11.5, CD Abstract Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations M., W. Saman, K. Vajen* Sustainable
More informationFirst Use Safety Recommendation
PX80 Hair Dryer First Use Safety Recommendation Please read through this booklet for safe and efficient use of the appliance. We urge you to read the "Hint's" section and also follow all detailed instructions
More informationAHRI Certification Program Scopes - COOLING
Air-to-Air Energy Recovery Ventilators (AHRI Std. 1060) Automatic Commercial Ice-Cube Machines and Ice Storage Bins (AHRI Stds. 810 & 820) Central Station Air-Handling Units (AHRI Std. 430) Commercial
More informationHUMIDIFICATION-DEHUMIDIFICATION SYSTEM IN A GREENHOUSE FOR SUSTAINABLE CROP PRODUCTION
Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 849 HUMIDIFICATION-DEHUMIDIFICATION SYSTEM IN A GREENHOUSE FOR SUSTAINABLE CROP PRODUCTION J.S. Perret 1 ; A.M. Al-Ismaili
More informationPsychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart
Psychrometrics Outline What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart Dry bulb temperature, wet bulb temperature, absolute humidity, relative humidity, specific
More informationCIRCA Ceiling Range. Ceiling products designed to meet a wide range of applications and compliment any ceiling décor
CIRCA Ceiling Range Product Guide Simple, speedy installation Pendant sets for maximum convenience Lamp activated range Litesaver BC3 low energy range Ceiling products designed to meet a wide range of
More informationDepartment of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics
Department of Mechanical Engineering ME 3 Mechanical Engineering Thermodynamics Lecture 34 The Psychrometric Chart Psychrometric Properties in EES Air Conditioning Processes Moist Air Properties Using
More informationFor an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.
1 PSYCHROMETICS Psychrometry is the study of the characteristics of moist air. We will see soon that evaporation of moisture from the skin can have a significant impact on thermal comfort. The rate of
More informationPerformance Rating of Active Chilled Beams
AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of
More informationDesign Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System
Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,
More informationANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications
ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications Approved by ANSI on 19 November 2014 IMPORTANT SAFETY DISCLAIMER AHRI does not
More informationPerformance Assessment of Water Cooled Condenser Refrigeration System
Energy and Power 2017, 7(3): 70-74 DOI: 10.5923/j.ep.20170703.03 Performance Assessment of Water Cooled Condenser Refrigeration System Sheetal Narayan Shetty *, Prashanth Kamath Department of Mechanical
More informationFlammability and New Refrigerant Options
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.trane.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information
More information(OR09B) First Use Safety Recommendation
Oil Filled Radiator (OR07B) (OR09B) (OR11B) First Use Safety Recommendation Please read through this booklet for safe and efficient use of the appliance. We urge you to read the Hints section and also
More informationDES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling
DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z
More information