First Trace Heating Product Details

Size: px
Start display at page:

Download "First Trace Heating Product Details"

Transcription

1 First Trace Heating Product Details and specifying guide Contents Refrigeration Safe Trace Product Diagrams 11 Components

2 Introduction Specification Maximum Exposure Temperature Minimum Installation Temperature 85 C (continuous power on) -40 C Minimum Bending Radius 35mm at -60 C; 13mm at 20 C Supply Voltage Chemical Resistance 230v (110v on request) Trace 10 Trace 20 Trace 30 Frost protection of pipework and vessels for non hazardous area applications,without steam cleaning. Water lines and process pipework can become a real problem when ambient temperatures drop below freezing. It is only when products thaw that one realises the damage and expense a failed pipe can cause. Our Range of parallel circuit self regulating heating cables are inherently temperature safe and can be cut and terminated on site to suit the required application. Our range of heaters are most suitable for protection of pipes against freezing in winter,and low temperature maintenance to 30 C Incorporating our range of IP67 weatherproof air and pipe sensing thermostats, accurate protection and control of heating is achieved. Suitable for corrosive environments. For specific chemical resistance consult First Trace Heating. Applications Carbon Steel Stainless Steel Plastic and Copper pipes Insulated Heating Jackets FROST PROTECTION Pipes and vessels Firewater mains Chiller pipe-work DHW and Heating pipe-work TEMPERATURE MAINTENANCE Process pipe-work up to 30 C Chocolate Edible oils Caustic Lines Thermal Output Rating Nominal power output at 230 Vac on insulated steel pipes 40 W/m Power Output 30 W/m 20 W/m 10 W/m 0 W/m 0 C 10 C 20 C 30 C 40 C 50 C 60 C Pipe Temperature Power Output Trace 30 30w/m at 10 C Trace 20 24w/m at 10 C Trace 10 10w/m at 10 C

3 Product Guide MODIFIED POLYOLEFIN OUTER JACKET TINNED-COPPER BRAID MODIFIED POLYOLEFIN JACKET MOISTURE BARRIER SELF-REGULATING CONDUCTIVE CORE COPPER BUS WIRE Maximum Circuit Lenghts MCB type C 230v only 16A 20A Trace Trace Trace The use of a 30mA residual current device to provide maximum safety is recommended. Selection Guide for Freeze Protection of pipes for up to minus 20 C Insulation Thickness 15mm - 54mm 76mm 89mm 114mm 168mm 219mm 273mm 324mm ½in - 2in 2½in 3in 4in 6in 8in 10in 12in 20mm Trace10 n/a n/a n/a n/a n/a n/a n/a 25mm Trace10 Trace10 Trace20 Trace20 Trace20 Trace20 n/a n/a 30mm Trace10 Trace10 Trace10 Trace20 Trace20 Trace20 Trace30 Trace30 40mm Trace10 Trace10 Trace10 Trace10 Trace20 Trace20 Trace30 Trace30 50mm Trace10 Trace10 Trace10 Trace10 Trace20 Trace20 Trace30 Trace30 Recommend all pipework over 6in to be spiralled 3

4 W55 Introduction The W55 range of parallel circuit self regulating heating cables is the perfect solution for hot water temperature maintenance of pipes installed in offices, hotels, sports centres, domestic dwellings etc. Our range of heaters provide instant hot water from every tap or shower unit when installed on a non-circulating installation. Heaters regulate their power output to compensate for the variation in water and ambient air temperatures. Our heaters eliminate the need for designing complex re-circulating systems with pumps, valves and return pipes, thereby providing low installation costs. The temperature in the pipes are maintained by varying the thickness of the thermal insulation in line with the pipe diameters. Insulation thicknesses are based on those commercially available in order to maintain the minimum temperatures stated in an ambient of 18 C. For exact temperature control a temperature control device may be required. If in doubt please consult First Trace Heating Specification Maximum Exposure Temperature 100 C (continuous power on) Maximum Maintenance Temperature 65 C Minimum Installation Temperature -40 C Minimum Bending Radius 35mm at -40 C; 13mm at 20 C Supply Voltage 230v (110v on request) Maximum Circuit Length 100m (20Amps MCB type C) Thickness 6mm Width 12.5mm Electrical Circuit Design Maximum Circuit Lengths. 55 C start up temperature. Maximum heating cable length per circuit Amps Voltage Maximum Circuit Length Electrical Protection Sizing MCB Type C 16A 230v 80m 20A 230v 100m The use of a 30mA residual current device to provide maximum safety is recommended. For more detailed information please contact First Trace Heating

5 Product Guide MODIFIED POLYOLEFIN OUTER JACKET TINNED-COPPER BRAID MODIFIED POLYOLEFIN JACKET MOISTURE BARRIER SELF-REGULATING CONDUCTIVE CORE COPPER BUS WIRE 55 C Temperature Maintenace Recommended Insulation Schedule Pipework Location Internal Mean Ambient Temperature 18 C Maintain Temperature Nominal 55 C 15mm 22mm 28mm 35mm 42mm 54mm 67mm Mineral Wool Insulation Thickness 20mm 20mm 25mm 30mm 40mm 50mm 50mm Phenolic Foam Insulation Thickness 15mm 15mm 15mm 20mm 25mm 25mm 25mm 65 C Temperature Maintenace Recommended phenolic foam insulation Schedule Pipework Location Internal Mean Ambient Temperature 18 C Maintain Temperature Nominal 65 C 15mm 22mm 28mm 35mm 42mm 54mm 67mm Phenolic Foam Insulation Thickness 20mm 20mm 20mm 25mm 30mm 30mm 30mm 5

6 FTH 50 FTH 30 Introduction Our FTH 30/50 series of heaters shows an excellent capability to maintain medium process temperatures of pipework and vessels. Temperatures up to 65 C are maintained with a maximum exposure temperature of 110 C. All heaters have a metalic braid and a modified polyolefin outer jacket and are available in 230 V and 110v on request. All heaters are parallel circuit and can be cut and terminated on site to suit the required application. Refer to our heaters schedule on page 8 to detemine the correct heaters product. Incorporting our range of IP67 pipe sensing thermostats, accurate protection and control of process pipework is achieved. Specification Maximum Exposure Temperature 100 C (continuous power on) Minimum Installation Temperature -40 C Minimum Bending Radius 35mm at -40 C; 13mm at 20 C Supply Voltage 230v (110v on request) Applications Carbon Steel Stainless Steel Plastic and Copper pipes Insulated Heating Jackets TEMPERATURE MAINTENANCE Process pipe-work up to 65 C Chocolate Edible oils Caustic Lines Fuel Lines Thermal Output Rating Nominal power output at 230 Vac on insulated steel pipes 60 W/m 50 W/m Power Output 40 W/m 30 W/m 20 W/m 10 W/m Power Output FTH 50 50w/m at 10 C FTH 30 30w/m at 10 C 0 W/m 0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 80 C Pipe Temperature

7 Product Guide MODIFIED POLYOLEFIN OUTER JACKET TINNED-COPPER BRAID MODIFIED POLYOLEFIN JACKET MOISTURE BARRIER SELF-REGULATING CONDUCTIVE CORE COPPER BUS WIRE Maximum Circuit Length Electrical Protection Rating type C MCB Maximum Heating Cable Length per Circuit Start up Temprature FTH 30 FTH 50 16A 10 C 70m 45m 20A 10 C 90m 60m 25A 10 C 115m 75m 32A 10 C 115m 100m Maximum Circuit Lengths Grouped to Individual type C MCB Trace20 Trace30 FTH 30 FTH 50 16A 90m 70m 70m 45m 20A 110m 85m 90m 60m 25A 120m 105m 115m 75m 32A 120m 110m 115m 100m TRACE 20 and TRACE 30 Refer to Thermal Output rating graph on page 8 to determine power outputs 7

8 FTH 50 FTH 30 Selection Guide For of pipes in ambient temperatures of minus 10 C 20 C Insulation Thickness 15mm 20mm 25mm 32mm 40mm 50mm 89mm 100mm ½in ½in 1in 1¼in 1½in 2in 3in 4in 25mm Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 30mm Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 40mm Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 Trace20 30 C Insulation Thickness 15mm 20mm 25mm 32mm 40mm 50mm 89mm 100mm ½in ¾in 1in 1¼in 1½in 2in 3in 4in 25mm Trace20 Trace20 Trace20 Trace20 FTH 30 FTH 30 FTH 30 FTH 30 30mm Trace20 Trace20 Trace20 Trace20 FTH 30 FTH 30 FTH 30 FTH 30 40mm Trace20 Trace20 Trace20 Trace20 FTH 30 FTH 30 FTH 30 FTH C Insulation Thickness 15mm 20mm 25mm 32mm 40mm 50mm 89mm 100mm ½in ¾in 1in 1¼in 1½in 2in 3in 4in 25mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 30mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 40mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH C Insulation Thickness 15mm 20mm 25mm 32mm 40mm 50mm 89mm 100mm ½in ¾in 1in 1¼in 1½in 2in 3in 4in 25mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 50 FTH 50 FTH 50 FTH 50 30mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 40mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH 30 FTH C Insulation Thickness 15mm 20mm 25mm 32mm 40mm 50mm 89mm 100mm ½in ¾in 1in 1¼in 1½in 2in 3in 4in 25mm FTH 30 FTH 30 FTH 50 FTH 50 FTH 50 FTH 50 FTH 50 FTH 50 30mm FTH 30 FTH 30 FTH 30 FTH 50 FTH 50 FTH 50 FTH 50 FTH 50 40mm FTH 30 FTH 30 FTH 30 FTH 30 FTH 50 FTH 50 FTH 50 FTH

9 Refrigeration Drain Line Heaters Double Insulated Round Self Regulating Heater that can be used internally or externally of a drain line. All Heaters come pre-terminated with a 1 meter flex. Part No. Length of Heater 18w/m at 10 C 40w/m at -20 C Drainline 1 1m Drainline 2 2m Drainline 3 3m Drainline 4 4m Drainline 5 5m Drainline 6 6m Base Cable Heater with single layer of insulation which can be used in cold store door casing, refrigeration glass cabinets and as a belly heater. Can be cut to any length. Part No. Base Cable 16 Base Cable 26 Small Geometry Base Cable v 230v 230v MODIFIED POLYOLEFIN JACKET MOISTURE BARRIER SELF-REGULATING CONDUCTIVE CORE COPPER BUS WIRE Safe Trace SafeTrace is a quick and safe frost protection solution suitable for DIY. Ideal for domestic applications and caravans frost protection. The System is pre-terminated with a built in thermostat and comes complete with a power on and heater energised LED indicator and 1m cold lead. Part No. Safetrace6 SafeTrace10 SafeTrace15 SafeTrace20 SafeTrace25 Length of Heater 6m 10m 15m 20m 25m Voltage 230v 9

10 Product Diagrams Circuit Air Sensing Thermostat ref: SENSAIRE SA1 1x TRACE KIT J Heating Cable Trace 30 Trace 20 Trace 10 Junction Box ref: JUNCBOX W4 Double Trace up to 3m End Seal Circuit Heating Cable W55 End Seal Power Junction Box ref: JUNCBOX W4 1x TRACE KIT J Junction Box ref: JUNCBOX W4 3x TRACE KIT J Double Trace up to 3m

11 Components SENSAIRE SA C Air sensing thermostat WEATHER CAP A C Capillary sensing thermostat WEATHER CAP B 0-90 C WEATHER CAP C C Capillary sensing thermostat TRACE KIT J Termination Kit JUNCBOX W4 IP66 Junction Box FIXGL Adhesive glass cloth fixing tape 50m - 25m BRACKET JB Pipe mounted bracket BRACKET STAT Thermostat pipe mounting bracket Banding mm Banding Strapping WARNLABEL Caution warning label 11

12 FIRST TRACE HEATING DIRECT LIMITED Chain Caul Road, Riversway, Preston, Lancashire, England PR2 2PD T F E sales@ first-traceheating.co.uk W

AKOCable Heating Cable Solutions Electrical Tracing

AKOCable Heating Cable Solutions Electrical Tracing Heating Cable Solutions Electrical Tracing HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer cover Used in long

More information

Domestic Hot Water Application manual

Domestic Hot Water Application manual Document Electrical Heating category Product name Domestic Hot Water Application manual 90% of the Legionella bacteria dies within the first 2 min at 60 C Let Danfoss do the work Index Danfoss Group is

More information

AKOCABLE Heating Cable Solutions Electrical Tracing

AKOCABLE Heating Cable Solutions Electrical Tracing AKOCABLE Heating Cable Solutions Electrical Tracing www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer

More information

Documentation. Parallel Heating Cable. Type: ELP

Documentation. Parallel Heating Cable. Type: ELP Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

Drexan Energy Systems Inc.

Drexan Energy Systems Inc. Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING

More information

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection and Flow Maintenance Introduction XL-Trace System This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace

More information

Design Guide and Installation Details for Self-Regulating Heating Cable

Design Guide and Installation Details for Self-Regulating Heating Cable Design Guide and Installation Details for Self-Regulating Self-Regulating s Design Guide and Installation The RSCC 2700 self- regulating heating cable is available with either a tinned copper or stainless

More information

Data Sheet. Self regulating process heating tapes RS stock numbers ,

Data Sheet. Self regulating process heating tapes RS stock numbers , Data Pack K Issued March 1997 232-3333 Data Sheet Self regulating process heating tapes RS stock numbers 379-889, 379-974 The information contained within this sheet regarding applications and installation

More information

XL-Trace System Application and Design Guide

XL-Trace System Application and Design Guide R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection

More information

Polymer solutions Heating mat EM2-CM

Polymer solutions Heating mat EM2-CM 1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly

More information

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description Self-Regulating Protection D E C B A Self-Regulating, Energy Efficient Designed for Protection Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Protection Applications Protection

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution

More information

Toll Free:

Toll Free: 1 Pipe Trace Solutions Self-regulating Heat Trace Cable ProLine s self-regulating pipe tracing cable is an ideal solution for industrial, commercial residential pipe freeze protection as well as process

More information

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Technical Databook for Industrial Heat-Tracing Systems 2006/2007 R Technical Databook for Industrial Heat-Tracing Systems 2006/2007 www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the leading brands in industrial

More information

Fire Sprinkler Freeze Protection Design / Install Guide

Fire Sprinkler Freeze Protection Design / Install Guide Fire Sprinkler Freeze Protection Design / Install Guide Page 1 of 23 Fire Sprinkler System Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 System Overview Page 4 Fire Suppression

More information

Toll Free:

Toll Free: Toll Free: 888.488.9276 www.warmzone.com sales@warmzone.com 19 Self-regulating Pipe Trace Cable Pipe Trace Solutions Self-regulating Heat Trace Cable Warmzone s self-regulating pipe tracing cable is an

More information

SILICONE RUBBER HEATERS

SILICONE RUBBER HEATERS 46 Hotco - industrial strength heating TM Hotco Silicone Rubber Tapes, Pads and Cord Heaters are made in Australia. Where flexibility and low to medium temperatures are required (-20 o C - + 220 o C) Silicone

More information

DESIGN GUIDELINES. THERMAL building SOLUTIONS

DESIGN GUIDELINES. THERMAL building SOLUTIONS DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel

More information

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q Documentation Glass -/quartz insulated Heating Cable Factory terminated Type: ELK-H, -HS, -Q ELW-H, -HS, -Q 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of

More information

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents. Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued

More information

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations Self Regulating Trace Heating Systems Installation and Maintenance Non-Hazardous Area Installations Installation Heating tape should be installed on clean, dry pipe free from burrs, weld splatter or any

More information

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Installation Manual. Frost Protection Cable. Warmup Ireland Web:     Telephone: Installation Manual Frost Protection Cable Warmup Ireland Web: www.warmup.ie Email: ie@warmup.com Telephone: 1 800 937 429 TECHNICAL HELPLINE 0845 345 2288 IMPORTANT Read this manual before attempting

More information

Heating Cables and Tapes. Technology. Constant wattage tapes

Heating Cables and Tapes. Technology. Constant wattage tapes Heating Cables and Tapes Technology Heating cables and tapes are one of the most versatile product lines in the Isopad range. Available in a vast array of technologies, the Isopad range is surpassed by

More information

Technical Databook for Industrial Heating Systems

Technical Databook for Industrial Heating Systems Technical Databook for Industrial Heating Systems R 2003 / 2004 Edition www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the five leading brands

More information

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace fire sprinkler freeze protection system. For other applications

More information

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information,

More information

Data Sheet. Self regulating heating tapes. RS stock numbers

Data Sheet. Self regulating heating tapes. RS stock numbers Data Pack K Issued September 2001 232-3125 Data Sheet Self regulating heating tapes RS stock numbers 379-312 The information contained within this sheet regarding applications and installation of RS WinterGard

More information

Self-regulating Roof Heat and Gutter Trace Cable

Self-regulating Roof Heat and Gutter Trace Cable Self-regulating Roof Heat Gutter Trace Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable. The heat cable can be installed in gutters downspouts to keep

More information

PLSRR Heat Trace Cable Data Sheet

PLSRR Heat Trace Cable Data Sheet PLSRR Heat Trace Cable Data Sheet PLSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing. The cable features a flexible, UV-stabilized thermoplastic elastomer overjacket

More information

INDUSTRIAL HEAT TRACE

INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com CABLE SELECTION Selecting the right cable is as much art as it is science. The chart below can help guide you through the selection of products

More information

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water

More information

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Thermal Devices, Inc. Mount Airy, Maryland USA   Heating Cable. Cut to Length in Field Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection D E C B A Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Freeze

More information

FreezGard. Self-regulating crankcase heater. Product Overview

FreezGard. Self-regulating crankcase heater. Product Overview Self-regulating crankcase heater Product Overview When compressors operate in cold areas, refrigerant can migrate into the crankcase oil whenever the compressor is not running. On start-up, this can cause

More information

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE   EUROPE, MIDDLE EAST, AFRICA WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917

More information

Self-regulating Roof Heat Cable

Self-regulating Roof Heat Cable Self-regulating Roof Heat Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable. The heat cable can be installed in gutters downspouts to keep structures safe

More information

Toll Free:

Toll Free: Toll Free: 888.488.9276 www.warmzone.com sales@warmzone.com 19 Self-regulating Roof Heat Gutter Trace Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable.

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty Introduction HWAT Design Guide This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information, contact your Pentair

More information

Commercial and Residential Self-Regulating Heating Products

Commercial and Residential Self-Regulating Heating Products Commercial and Residential Self-Regulating Heating Products Application and Design Guide H53585 (800) 545-6258 www.tycothermal.com Table of Contents Introduction 1 Heating Cables Selection Guide 1 Product

More information

Longline Heating. Contents. Introduction

Longline Heating. Contents. Introduction Longline Heating This section provides an overview of the longline heat-tracing technologies available from Pentair Industrial Heat Tracing Solutions. For complete design assistance, contact your Pentair

More information

Roof and Gutter De-Icing

Roof and Gutter De-Icing Roof and Gutter 1. Pipe Freeze Protection and Flow Maintenance Introduction IceStop System This step-by-step design guide provides the tools necessary to design a Raychem IceStop roof and gutter de-icing

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products Chromalox PRECISION HEAT AND CONTROL Cold Weather Electric Heat and Control Products INDUSTRIAL COMFORT HEATERS INDUSTRIAL COMFORT HEATERS Chromalox electric comfort heaters provide efficient, economical

More information

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide Hot Water Temperature Maintenance HWAT System Product Selection and Design Guide A Solutions Company Tyco Thermal Controls provides complete heat tracing and specialty wiring solutions for the industrial,

More information

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM ROOF AND GUTTER DE-ICING ICESTOP SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem IceStop roof and gutter de-icing system. For other applications or for design assistance,

More information

Selection guide for self-regulating heat-tracing systems

Selection guide for self-regulating heat-tracing systems R Selection guide for self-regulating heat-tracing systems R TraceCalc Net, software design in three easy steps: 1. Select your heat-tracing design 2. Enter the design data >> 3. Get a bill of materials

More information

Heating cable solutions for temperature-related problems

Heating cable solutions for temperature-related problems Heating cable solutions for temperature-related problems EasyHeat Residential and Commercial Solutions Depend on EasyHeat products for proper pipe temperatures, free-flowing roof gutters, safer walkways

More information

Principle of Operation:

Principle of Operation: SELF-REGULATING HEATERS Standard Overjacket Standard Metal Braid Stranded Copper Conductors Self Regulating Conductive Core Thermoplastic Elastomer Jacket Description: Nelson Type CLT selfregulating heater

More information

XL-Trace System Installation and Operation Manual

XL-Trace System Installation and Operation Manual XL-Trace System Installation and Operation Manual Pipe freeze protection and flow maintenance WARNING: Fire and shock hazard. This heat-tracing system must be installed correctly to ensure proper operation

More information

R407C Cellar Cooling. Fansets: Single phase, high efficiency, low

R407C Cellar Cooling. Fansets: Single phase, high efficiency, low R07C Cellar Cooling Introduction The New Cellarmaster from Climate Center is a simple cost effective range to provide cooling for the smaller cellars within the beer and wine cooling industry. A small

More information

Snow melting for ramps, access ways, and footpaths

Snow melting for ramps, access ways, and footpaths Snow melting for ramps, access ways, and footpaths Ice and snow on paths, loading bays, driveways, ramps, stairs and other access ways, can present a major problem causing accidents and delays. To help

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS INDUSTRIAL AIR AND INFRARED RADIANT HEATERS Portable Unit Heaters Portable electric heaters are available in radiant-heat or fan-forcedair designs.

More information

Freezer Frost Heave Prevention

Freezer Frost Heave Prevention Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS DESCRIPTION The PLT-L Series End of Circuit Light Kit is for use with all versions of LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables smaller than 11mm (.44 ) diameter.

More information

Technical handbook. Temperature maintenance and frost protection systems

Technical handbook. Temperature maintenance and frost protection systems R Technical handbook Temperature maintenance and frost protection systems Useful instructions for the use of this technical handbook For your customers... For the worksite... COPY FAX COPY COPY The as

More information

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design Technology Metal drum heater design Drum H eaters Isopad offers a range of drum and base heaters that provide a reliable way to reduce viscosity, protect stored product from frost and enable product removal.

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

SELF-REGULATING PIPE TRACING HEATER CABLE

SELF-REGULATING PIPE TRACING HEATER CABLE SELF-REGULATING PIPE TRACING HEATER CABLE Installation & Operation Manual TABLE OF CONTENTS GENERAL INFORMATION... 1 How Heating Systems Work...1 PRODUCT SELECTION... 1 RECEIPT & STORAGE... 1 Receipt...1

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately

More information

Frequently Asked Questions

Frequently Asked Questions Air Source Heat Pumps Frequently Asked Questions Heating that doesn t cost the earth What are the benefits of Air Source Heat Pumps over Ground Source Heat Pumps? There are a number of benefits when using

More information

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life, Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life, based on sophisticated technology. Quality Global Technology

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

Consignes d installation

Consignes d installation PBS-200-A Single entry power junction box Installation Instructions PBS-200-A Single entry power junction box with cold applied connection technology for use with BARTEC PSB / HSB trace heaters Consignes

More information

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS DESCRIPTION The ALT- continuity monitor device is used to monitor bus continuity on a parallel type heater cable. After the heater cable is installed on the pipe, connect the ALT- to the opposite end of

More information

Quality Underfloor Heating

Quality Underfloor Heating Quality Underfloor Heating from The Floor Warming Company 1 Quality Underfloor Heating Quality underfloor heating from The Floor Warming Company Q. Why is our underfloor heating so much better than competitors?

More information

C Electrical Connection Kit

C Electrical Connection Kit 1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit

More information

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS DESCRIPTION The PLT-BY Tee Splice Connection Kit is for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables small

More information

Technical Handbook

Technical Handbook Technical Handbook 2010 2012 Smart heat for comfort and safety Smart heat for comfort and safety As the world leader in heat-tracing systems, Tyco Thermal Controls has the system that you need from pipe-freezing

More information

GENERAL SPECIFICATION ELECTRICAL

GENERAL SPECIFICATION ELECTRICAL GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Flexelec Catalogue D-3. Delivering Certainty hamer.co.nz. Version

Flexelec Catalogue D-3. Delivering Certainty hamer.co.nz. Version Flexelec Catalogue D-3 Delivering Certainty hamer.co.nz Version - 2070 About us From humble beginnings to being stronger than ever before, our philosophy at Hamer is simple: deliver the best quality electrical

More information

Hot Water Temperature Maintenance Product Selection and Design Guide

Hot Water Temperature Maintenance Product Selection and Design Guide Hot Water Temperature Maintenance Product Selection and Design Guide A Solutions Company Tyco Thermal Controls provides complete heat tracing and specialty wiring solutions for the industrial, commercial,

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering

More information

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration. MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK IMPORTANT: This booklet should be given to the customer after installation and demonstration. Description of water heater 1) Hot water outlet 2) Temperature

More information

Carbon Film Installation Instructions

Carbon Film Installation Instructions Contents Page 2 Page 3 Page 4 Page 5 Page 8 Product Overview Pre-Installation & Electrical Provision Depron Underlay Installation Carbon Film Installation - Under Wood/Laminate Flooring Notes & Trouble

More information

Installation and Operation. Installation systems for pipes EKL/EMK

Installation and Operation. Installation systems for pipes EKL/EMK Installation systems for pipes EKL/EMK Introduction This BARTEC instruction manual for installation and operation is intended to give you important information on electric trace heating systems for pipes.

More information

Toll Free:

Toll Free: 1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the

More information

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately

More information

NELSON HEAT TRACING SYSTEMS INSTALLATION

NELSON HEAT TRACING SYSTEMS INSTALLATION DESCRIPTION The ALT-BY Tee Splice Connection Kit is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any

More information

www.yorkshirecopper.com Kuterlex Plastic Coated Copper to BS EN 13349/1057 BS EN 1057 Kuterlex is copper tube coated with a seamless plastic cover which protects the copper tube against aggressive materials.

More information

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS DESCRIPTION The Raychem HWT-P Power Connection and End Seal Kit is for use with HWAT heating cables. Materials for one power connection

More information

Parallel Heating Cables Standard types... 24

Parallel Heating Cables Standard types... 24 Heating Cables Heating Cables Index Page Selfregulating Heating Cables Standard types 65-100 C... 4 High temperature 210-250 C... 14 DomoClick, connection technique... 20 Technical information... 22 Parallel

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE WATERHEATER MANUFACTURERS ASSOCIATION Tel 01952 257963 Fax 01952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com STAINLESS PRODUCTS Tornado &

More information

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION Ecoline Geo RI HP INSTALLATION MANUAL The Ecoline GEO is an indirect unvented cylinder designed and approved for use with a heat pump. The

More information

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing Electrical Heat Tracing in Hazardous Areas innovations in heat tracing Table of Contents Introduction 3 1. Heating Cables Type ELSR-N Self-regulating Heating Cable up to 80 C 4-5 Type ELSR-LS Self-regulating

More information

CABLE SERVICES. Data Input Sheet - Fax Back

CABLE SERVICES. Data Input Sheet - Fax Back Trace Heating Guide Data Input Sheet - Fax Back 3 TRACE HEATING GUIDE Distributor of Trace Heating Products for 25 Years (Northwest) Ltd Tel 01978 356948 (UK) Ltd Tel 01978 3450 (Central) Ltd Tel 01782

More information

SERGE BARIL GTKB GUT TRACE KIT BAG

SERGE BARIL GTKB GUT TRACE KIT BAG Description: The GTKB Gut Trace Kit Bag includes the power cord connection with the GFI Plug and end seal. It is for use with FPS-BT & IN-PIPE type heater cables. Kit Contents: 1 Compression Fitting 3

More information

ADVANCE ELECTRIC THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal

More information

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers Construction Characteristics The ideal solution for applications that require high watt densities (Watt/in 2 ) and/or high operating temperatures. Band heaters are capable of temperatures up to 760 C (1400

More information

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal management WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD.

More information