Introduction to Pool Heat Pumps

Size: px
Start display at page:

Download "Introduction to Pool Heat Pumps"

Transcription

1 Introduction to Pool Heat Pumps Air-to-water pool heat pumps are seeing more and more popularity in the climates that can support them over the more traditional gas and electric pool heaters we usually see. While they definitely contain some familiar operating principles to an air-to-air heat pump, there are some striking differences in the way the heat is transferred as well as how the components are controlled and protected. Heat Exchange in a Pool Heat Pump Most residential and light commercial heat pumps are packaged systems, containing all but a few necessary components for it to perform its duty of heating the body of water it serves. We have some strong similarities with an air-to-air system: a large air coil mounted on its perimeter, an outdoor fan to

2 perform heat exchange over this coil, a compressor to pump refrigerant, and a metering device to control the capacity delivered to the evaporator. On many, you ll also find a liquid receiver and / or a suction accumulator to make up for the wide temperature loads they re designed to handle. The system gets interesting with the introduction of a water coil. There are two different types of common water coils in use currently. The first one we ll go over is the coaxial coil. This is a coil inside a coil, designed to rapidly exchange heat between the refrigerant and water we re adding heat into. The mainstay material for coaxial coils has been a unique alloy of copper (Cu), nickel (Ni), iron (Fe), and manganese (Mn), known as cupronickel (pictured above.) It has all of

3 the pressure characteristics of copper, but with the added benefit of being much more resilient to corrosion from a variety of sources. Interestingly, all of the silver U.S. coinage is made with this same alloy. Titanium (Ti), while less noble than copper, has also entered the market as an alternative to cupronickel with a lighter weight and greater corrosion resilience. However, these coils are often larger in size given titanium exchanges heat less effectively than copper and is much more difficult to work. Coaxial coils are fairly simple in their construction. The outside of the coil carries refrigerant, while the inside handles the water. These coils are designed to counterflow the two mediums in order to exchange heat rapidly. The inside of the coil is also rifled, creating a swirling effect that helps this process along further (see the diagram below.) An alternative heat exchanger that s used is the tube in shell coil, which, just as its name implies, is a refrigerant coil inside of a water tank. Counterflow makes an appearance here as well, passing the influent water across the effluent refrigerant. Depicted below is a dome-style tube in shell titanium coil. This particular coil is found in a water-towater pool heat pump. Note how the copper adjoins to the titanium using a ferrule just before entering the coil.

4 Safeties and Controls Pool heaters are thermostatically controlled just as you would expect. In most cases water temperature is measured with a thermistor inserted into a temperature well that contains a heat conductive paste to provide the most accurate measurement of the water flowing across it. These are made of either a polymer composite, brass, or copper. They also double as a safety measure on systems employing cupronickel as they will breach first should a chemistry imbalance present in the pool water, alerting service persons before a water flooded refrigeration system occurs.

5 Another unique safety we ll discuss is the water flow switch. This switch is akin to the pressure fall switches found inside induced draft furnaces. They contain a pressure sensitive diaphragm connected to a normally open switch that closes when pressure is applied, thus informing the unit control when water flow is absent. Just like air-over designs, a refrigerant coil with no water to transfer heat into can be severely detrimental to the compressor it serves. High discharge pressures can result, leading to premature mechanical failures. While a high-pressure refrigerant cutout may also be employed, this water flow safety acts as a first response to protect the system from catastrophic damage. This will prevent the system from operating whether the pool pump is off due to scheduled downtime, a power interruption occurs, a pool filter becomes impacted, or any other condition that ceases water flow. A majority of systems contain an internal water bypass that controls how many gallons per minute are allowed to flow through the condenser coil. Too much supply water and the temperature rise will be too low; too little, and the

6 temperature rise will be too high. This is one of the most important contributing factors to efficiency in an air-towater system. These bypasses are usually preset by the factory without any adjustment required in the field. Be aware that there will likely be an external bypass as well which can wreak havoc on the heater operation should it be tampered with. Remember to check these first if the water flow switch is keeping the system off! Similarly to air-to-air systems, air-to-water heat pumps will occasionally require defrost cycles during cold weather. This is achieved primarily by demand defrost with a temperature sensor affixed to the air coil. Care needs to be taken with the placement of these sensors, as a quickly frosting circuit can produce short cycling of the equipment. Pools and spas tend to lose heat very quickly, and recovery can become impossible with excessive defrost cycles during cold days. Finally, many heat pumps will feature a method to pair multiple units to cycle on and off together to provide extra capacity for large pools. This helps keep equipment wear to the minimum as all heat pumps will be operating in concert during a demand cycle. In Conclusion While pool heating can be daunting at first glance, they are relatively simple machines that are usually easy to service with some prior exposure. The basic refrigeration principles all remain the same. The next time a customer asks you why their pool is cold, don t shy away from getting some hands-on experience. You may find a niché at your company! Zach

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications UNIT OBJECTIVES After studying this unit, the reader should be able to Discuss space temperature control. Describe

More information

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 3 Explain the operation of a simple ice

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

REFRIGERATION PRODUCTS

REFRIGERATION PRODUCTS REFRIGERATION PRODUCTS Product Catalog REFRIGERATION PRODUCTS PAUL MUELLER COMPANY Table of Contents 3 x 5 Falling Film Chiller.................................... 1 4 x 8 Falling Film Chiller...................................

More information

Important Facts You Should Know About Your Heat Pump (602) or (520)

Important Facts You Should Know About Your Heat Pump (602) or (520) Important Facts You Should Know About Your Heat Pump (602) 943-3426 or (520) 292-6858 www.chasroberts.com During the cooling season, the heat pump operates like a conventional system. Do Not turn the air

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve

Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve HVAC Maintenance Checklist Template conducted for Sunny Hills Conducted on 31 Oct 2018 03:40 PM Prepared by Jon Nieve Location 102 S Mendel St, Fort Stockton, TX 79735, USA Completed on 31 Oct 2018 04:11

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI. COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com Steam-Fired Domestic Hot Water Generator COBREX

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning Choose the winning team Heat transfer technology for industrial cooling and air conditioning Alfa Laval makes it easy Buying heat exchange components for industrial cooling and air conditioning projects

More information

(EE1500, EE2000, EE2500, EE3000)

(EE1500, EE2000, EE2500, EE3000) EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

OACS Outdoor Air-Cooled Central Chillers

OACS Outdoor Air-Cooled Central Chillers OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb

Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb Figure 22-2 Enthalpy change through the evaporator Figure 22-3 Two aluminum domestic refrigeration evaporators Figure 22-4

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 10 SEER Standard Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F Count on Graham for proven reliability. Graham is one of the world s foremost designers and manufacturers of vacuum and heat transfer equipment with over a half-century of proven experience. Our in-house

More information

User s Information/Installation Instructions

User s Information/Installation Instructions Outdoor Heat Pump User s Information/Installation Instructions 12 SEER High Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with A.R.I. Standards.

More information

Innovative tube products for more comfort, energy efficiency and resource conservation

Innovative tube products for more comfort, energy efficiency and resource conservation Wieland-Werke AG Graf-Arco-Str. 36 89079 Ulm Ulm, 19 August 2016 Innovative tube products for more comfort, energy efficiency and resource conservation At the Chillventa in Nuremberg from 11 to 13 October

More information

UHS Heater. How To Guide. HTG-UHS17a. Copyright 2017 Hayward Industries Inc.

UHS Heater. How To Guide. HTG-UHS17a. Copyright 2017 Hayward Industries Inc. UHS Heater How To Guide HTG-UHS17a Copyright 2017 Hayward Industries Inc. How To: Program Heater Bypass Operation Follow the included steps to place the heater in bypass mode for external control. Step

More information

Installation Instruction

Installation Instruction Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,

More information

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation EVAPORATOR DEFROSTING: WHEN AND WHY The refrigeration evaporator is a container that provides room for the evaporating refrigerant. The refrigerant receives heat by conduction through the walls of the

More information

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL MODEL AT105 AT115 AT130 with Titanium Heat Exchanger 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com DIGITAL

More information

ParaWeld Plate Heat Exchangers

ParaWeld Plate Heat Exchangers APV HEAT EXCHANGER Product Name / Title Subtitel / C=20 M=0 Y=0 K=28 ParaWeld Plate Heat Exchangers WELDED PAIR PLATE HEAT EXCHANGER FOR REFRIGERATION About APV SPX FLOW provides advanced APV heat transfer

More information

Soil Management Site Selection, Soil Fertility. Warren Roberts George Kuepper

Soil Management Site Selection, Soil Fertility. Warren Roberts George Kuepper Soil Management Site Selection, Soil Fertility Warren Roberts George Kuepper Where We re Going Soil Texture and Drainage Site Selection Soil Fertility & ph Fertilizers & Nutrients Later Sessions Soil Biology

More information

OWNER S MANUAL Models AT75 & AT110

OWNER S MANUAL Models AT75 & AT110 POOL & SPA HEAT PUMP OWNER S MANUAL Models AT75 & AT110 POOL & SPA HEAT PUMPS 2213 Andrea Lane Fort Myers, FL 33912 (239) 482-0606 FAX: (239) 482-7737 (888) 297-3826 www.aquathermheatpumps.com MODEL SERIAL

More information

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job. June 01 / BULLETIN - 3-Way Valves The right solenoid valve for any job. Page 2 / Bulletin - Advantages Sporlan 3-Way Valves 3-Way Pilot eliminates costly high- to low-side leaks. "B" reduces total installed

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE

FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE 2015.02 Version 6 Jimmy Chan FORTUNE SMART INDUSTRIAL LIMITED 8F International Garden B No.160 Tianmushan Road Hangzhou China Tel:86-571-85023341 Fax:86-571-85023549

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS Built Exclusively for Manufactured Housing Proven components Fully insulated cabinets Miller is a household name. Miller is a household name

More information

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002 TM TOPIC: Heat Pumps GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002 This is the eighth in a series of technical bulletins in which an over-all examination of the home will be discussed as

More information

MEDICAL CHILLER SYSTEMS

MEDICAL CHILLER SYSTEMS Mission Critical Chilled Water Systems Engineered to Exacting Standards Magnetic Resonance Imaging Systems CT Scanners Oncology Linear Accelerators Blood Cooling Systems Precise Laboratory Applications

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions 4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents

More information

C22FC Bulletin # October 1993 Supersedes May 1993

C22FC Bulletin # October 1993 Supersedes May 1993 ENGINEERING DATA C22 FC SERIES FULL CASED EVAPORATOR UNITS UP-FLO AIR-CONDITIONING AND HEAT PUMP *13,000 to 63,000 Btuh (3.8 to 18.5 kw) Cooling Capacity *ARI Standard 210/240 Certified Ratings with Matching

More information

ParaWeld Plate Heat Exchangers

ParaWeld Plate Heat Exchangers apv heat exchanger Product Name / Title Subtitel / C=20 M=0 Y=0 K=28 ParaWeld Plate Heat Exchangers Welded Pair Plate Heat Exchanger for Refrigeration SPX offers an extensive portfolio of plate heat exchanges

More information

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. Perfectemp Swimming Pool Heat Pump CE OWNER S MANUAL Models PT4, PT6, and PT8 R C LISTE D 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water Unique Solutions for All-Indoor HVAC Projects MiniCool United CoolAir Breaks

More information

Condensing Units w/ Screw Compressors

Condensing Units w/ Screw Compressors w/ Compressors Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved

More information

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers For Industrial Refrigeration HEAT EXCHANGERS Frick Quality Heat Exchanger Solutions Proven Technology LaZerWeld Plate Heat

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Typical Piping Diagram

Typical Piping Diagram Catalog C-1, Accumulators and Receivers / Page 3 Typical Piping Diagram Models Available HGBE Discharge Bypass Line Solenoid Moisture & Indicator CROT Crankcase Pressure Regulating EBV Ball Hot Gas Solenoid

More information

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation INTRODUCTION In recent years air conditioning industry technology has advanced rapidly. An important byproduct of this growth has been development of the heat pump. Altogether too much mystery has surrounded

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com

More information

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC VOLUME ONE NUMBER THREE SYNOPSIS A N H V A C N E W S L E T T E R F O R B U I L D I N G O W N E R S A N D M A N A G E R S In this issue... Part-Load Strategies Why they re important.......... 1 What Things

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL NEPTUNE OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Neptune dehumidifier is a super high capacity industrial

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

Instructional & Operating Manual

Instructional & Operating Manual Instructional & Operating Manual For CoolFreeze Series Portable Refrigerators/Freezers CF-18, CF-25, CF-35, CF-40, CF-50, CF-80, CF-110 WAECO USA Clinton, CT www.waecousa.com Safety indications in the

More information

How about Savings in Time, Money, Energy and Longer Life?

How about Savings in Time, Money, Energy and Longer Life? Chapter 17: The Value of Maintaining Evaporative Cooling Equipment 97 The Value 17 of Maintaining Evaporative Cooling Equipment 1. Cooling Tower Maintenance and Upgrades... What s in it for You? How about

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

Drop-In Refrigeration System

Drop-In Refrigeration System Drop-In Refrigeration System Original Instructions Installation, Operation and Maintenance Manual This manual is updated as new information and models are released. Visit our website for the latest manual.

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck ow Brett Alexander Presenters Mihir Kalyani Troy Reineck Designing Your Water Treatment Program for Different Types of Heat Rejection Equipment Types of Heat Rejection Equipment Open Cooling Tower Closed

More information

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners Models Self-Contained & Split System Reverse Cycle Air Conditioners s 05-07-10-12-16-18-24 General Description Marvair's water source self-contained and split system reverse cycle air conditioners are designed

More information

Installation Instructions

Installation Instructions Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation

More information

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section COMMERCIAL SERIES Commercial Series Commercial Series Power switch & Nameplate location: NAMEPLATE: Single and Dual Section Must reach over behind Front Panel to access: Single and Dual Section Commercial

More information

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 5 Explain the purpose and operation of

More information

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-2 Commercial refrigeration Unit Figure 17-3 Industrial process chiller Figure 17-4 Basic refrigeration

More information

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions Quest CDG Dry 74 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R250 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R250 LGR Dehumidifier Coated Coils

More information

Standard Duct Heaters Open Coil

Standard Duct Heaters Open Coil HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass

More information

RDT Refrigeration Book

RDT Refrigeration Book RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.

More information

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS 072, 090, 120, 180 & 240 MODELS C SERIES P SERIES HEAT PUMPS SPLIT L SERIES SYSTEMS LSA Condensing Units 6 Thru 20 Ton (21.1 Thru 70.3 ) Heat Pumps 7.5 & 10 Ton (26.4 & 35.2 ) Bulletin #210164 February

More information

Bulletin , March Electric Hot Gas Bypass Valves

Bulletin , March Electric Hot Gas Bypass Valves Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital

More information

Air Conditioning Inspections for Buildings Condensers

Air Conditioning Inspections for Buildings Condensers . Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection

More information

Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors

Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors August 2017 Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Safety... 2 Safety Instructions... 2 Safety Icon Explanation... 2 Instructions

More information

THERMOSTATIC EXPANSION VALVES Part 1

THERMOSTATIC EXPANSION VALVES Part 1 Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 THERMOSTATIC EXPANSION VALVES Part 1 Revised by Loren Shuck, CMS INTRODUCTION The thermostatic expansion valve (frequently

More information

The Evolution of the Brewery Chiller System. A 20 year retrospective

The Evolution of the Brewery Chiller System. A 20 year retrospective The Evolution of the Brewery Chiller System By Jim VanderGiessen Jr, Pro Refrigeration Inc. A 20 year retrospective It is hard to believe it s been almost 20 years since we manufactured our first brewery

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS Built Exclusively for Manufactured Housing Proven components Fully insulated cabinets Miller is a household name. Miller is a household name

More information

CO2 TRANSCRITICAL BOOSTER SYSTEMS

CO2 TRANSCRITICAL BOOSTER SYSTEMS CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets

More information

Self-Contained Reverse Cycle Air Conditioners

Self-Contained Reverse Cycle Air Conditioners Self-Contained Reverse Cycle Air Conditioners Models MA 07-10-12-16-24 General Description Marvair's water source self-contained reverse cycle air conditioners are designed for use in either fresh or salt

More information

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors AE4-1296 R3 March 2013 Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Instructions... 2 Safety Icon Explanation... 2

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

Application of Air Source Variable Refrigerant Flow in Cold Climates

Application of Air Source Variable Refrigerant Flow in Cold Climates PREPARED BY Seventhwave with the assistance of Daikin North America, LLC Masters Building Solutions Application of Air Source Variable Refrigerant Flow in Cold Climates A White Paper March 2015 275-1

More information

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller INSTALLATION & OPERATING INSTRUCTIONS Effective 8-19-15 Thank you for purchasing an Aqua logic chiller. It has been designed and built to

More information

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE ANNEX III SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE The design of the heat exchanger is extremely important, as it is the key element of a

More information