LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment
|
|
- Ralph Golden
- 5 years ago
- Views:
Transcription
1 Combination Lavatory Water Closet Module Durable Epoxy-coated Stainless Steel Cabinetry Large, Conveniently Located s for Easy Installation and Maintenance Specifi cations Standard Equipment Cabinet Stationary cabinet is constructed of 14 gauge stainless steel and three access panels allow for easy installation and maintenance. Finish is BradGlaze Almond (BradGlaze White, BradGlaze Gray and Stainless Steel #4 Polish also available). Cabinet includes integral 12" grab bar. Countertop and Lavatory Countertop with integral lavatory is furnished with Bone colored cultured marble (Stainless Steel #4 Polish also available). Countertop measures 10"x 8"x 6" deep. Furnished with 10" rigid gooseneck, deck-mounted hot and cold faucet with 4" wristblade handles. Traps and stops complying with local codes to be furnished by plumbing contractor. Toilet Available in left or right side toilet configurations. Toilet is constructed entirely of 14 and 16 gauge stainless steel and will support a 5,000 lb. static load. Siphon jet type with elongated bowl, integral flushing rim, and remote-actuated hydraulic flushing system with push button. 25 PSI minimum is required for flushing. Trap has 3½" seal that will pass a 2 1 8" diameter ball and is fully enclosed. White seat with cover has selfsustaining hinge. A 1.6 gallon per flush (low flow) toilet is standard. Toilet assembly meets ANSI/ASME A Check Your Surroundings Certain factors, such as intense direct sunlight, other infrared devices, or other site conditions may interfere with the activation of infrared faucets. Contact your local Bradley representative to discuss any application concerns. LC500 NOTE: LC500 with optional roll-away seat (left-hand configuration shown). All Patient Care Units are non-cancelable and non-returnable because they are made to exact specifications for each order. Page 1 of 6
2 LEFT-HAND VERSION Cultured Marble Countertop with 8" x 10" (203mm x 254mm) Sink Heavy duty Hinged Seat with Cover TOP VIEW 29" (737mm) 33¼" (845mm) 2" (51mm) 4" Wristblade Centerset Faucet Standard " (349mm) CL Flush Actuator Grab Bar " (917mm) Recessed Tissue Holder with Shroud " (835mm) 10" x 24" (254mm x 610mm) 17" (432mm) FRONT VIEW SIDE VIEW Page 2 of 6
3 RIGHT-HAND VERSION Cultured Marble Countertop with 8" x 10" (203mm x 254mm) Sink Heavy-duty Hinged Seat With Cover TOP VIEW 4" Wristblade Centerset Faucet Standard 29" (737mm) 2" (51mm) 33¼" (845mm) " (349mm) Flush Actuator Grab Bar 10" (254mm) x 24" (610mm) " (835mm) Recessed Tissue Holder with Shroud " (917mm) 17" (432mm) FRONT VIEW SIDE VIEW Page 3 of 6
4 Model Description LC500 29" Patient Care Unit, Fixed Water Closet Required Selections (Must select one from each category) Water Closet Location (select one): LEFT Left-Side RIGHT Right-Side L R Water Closet Waste Outlet (select one): WALL Wall Waste Outlet FLOOR Floor Waste Outlet Water Closet Waste Connection (select one): 3NH 3" No-Hub Waste Connection 4NH 4" No-Hub Waste Connection 3NH 4NH Optional Selections SSRC-A SSRC-G SSRC-W SSRC-PS BWVC SGB WGB (BradGlaze Almond) (BradGlaze Gray) (BradGlaze White) (Stainless Steel #4 Polish) Bedpan Washer w/ Volume Control Valve Swing-Down Grab Bar 35" Long Wall Grab Bar 48" Long Cabinet Color (select one): ALMND BradGlaze Almond GRAY BradGlaze Gray WHITE BradGlaze White PS-CAB Polished Stainless Steel Countertop Color (select one): CM-BONE Cultured Marble, Bone PS Polished Stainless Steel* NO-TOP Less Countertop and Lavatory Other Other Other All Patient Care Units are non-cancelable and non-returnable because they are made to exact specifications for each order. Once you have determined your configuration, please contact your Bradley Representative for rough-in information. Lavatory Valve (select one): WB Deck-Mounted Faucet/Wristblade Handles FP Deck-Mounted Spout/Foot Pedal Control IR-AC Infrared Gooseneck Faucet* IR-DC Infrared Gooseneck Faucet, Battery-Operated* WB FP IR-AC / IR-DC Mixing Valve Selections (for IR Lavatory Valves): TMA TMA Vernatherm Thermostatic Mixing Valve * Infrared faucets not available with PS countertop selection. Page 4 of 6
5 LC500 Site Evaluation Check List Job Name: Location: Proposed Fixture Model No.: Room No.: Prepared by: Date: General Information Space available for fixture Width: Depth: WIDTH WIDTH Height: Windows Present Back Left Side Right Side DEPTH Note: Bradley LC500 Unit is 29"W x "D x "H DEPTH Corner Installation Yes Left Side Right Side No Structural Obstructions Pillars Lateral Beams Wall Studs Windows Offset Wall; Back, Side Curtains; Privacy Tracks Power Columns; Monitors Door Swings Traffic Pattern, Room Heat Vents Electrical Outlets Other Page 5 of 6
6 LC500 Site Evaluation Check List New Construction/Renovation/Remodel New Construction Lav/Water Closet Waste Rough-Ins Standard Fixture Dimensions Modified-To-Match Existing Locations Indicated Waste Outlet Size: Add Any Additional Rough-In Locations Required Renovation/Remodel Existing Fixture Manufacturer: Model No.: Existing W/C Waste Connection 3NH 4NH GSKT Waste Outlet Wall Floor Maintain Existing Rough-Ins Yes No *If Renovation/Remodel, please provide all existing rough-in dimensions which must be met. *Actual Rough-Ins Supplied on Submittals. NOTE: Rough-In Stubouts to be 2" typical. Page 6 of 6
TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.
OPT DWG DXF RFA SHOWERS Revit PDF files CSI available on our website HEALTHCARE PRODUCT GUIDE PLUMBING FIXTURES & ACCESSORIES MADE IN THE USA 800.428.4065 www.willoughby-ind.com 1 TABLE OF CONTENTS Products
More informationA. Section Joint Sealants: Seal fixtures to walls and floors.
SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2
More informationB. Shop Drawings: Include diagrams for power, signal, and control wiring.
SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.
More informationWF2613 Classic Corner Washfountain with 9" Deep Bowl
cupc Certified Available in a 54" Bowl Size 9" Deep Bowl, Designed for Heavy Duty Hand Washing Foot, Air Metering, Infrared or TouchTime Control Specifications Size and Capacity Accommodates three users
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers
More informationUniversity of Rochester October 17, 2008 Brooks Landing Business Center
SECTION 224200 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, equipment and services to perform operations required for the complete installation and related
More informationSN2003, SN2023, SN2004, SN2024
Reliable Push Button Activated Air Metering or Infrared Control Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height Model with Hand or Infrared Control Is ADA Compliant Factory
More informationWilloughby Industries - Security Products
TOILET WASTE LOCATION (ETW)- WALL OUTLET, BLOWOUT (ETF)- FLOOR OUTLET, SIPHON JET (ETWS)- WALL OUTLET, SIPHON JET FIXTURE MOUNTING (FM)- FLOOR MOUNTED (OF)- OFF FLOOR MOUNTED (OW)- OFF WALL MOUNTED INLET
More informationWF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications
cupc Certified 3 Rim Height 9" Deep Designed for Heavy Duty Hand Washing Reliable Air, TouchTime or Infrared activations Vandal Resistant - Easy to Clean Specifications Size and Capacity 3 floor to bowl
More informationHWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.
ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE
More informationWilloughby Industries - Security Products
TOILET WASTE LOCATION (ECW)- WALL OUTLET (ECF)- FLOOR OUTLET TOILET ORIENTATION (L)- ANGLED LEFT (L)- OFFSET LEFT (R)- ANGLED RIGHT (R)- OFFSET RIGHT (C)- CENTER FIXTURE MOUNTING (OF)- OFF FLOOR (ON)-
More informationLAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.
ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE
More informationWF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl
WF Model lassic Washfountains UP Approved Pre-Assembled owl and Pedestal Available in 5 or 36" iameter owl Size esigned for eavy uty and Washing Foot ontrol or Infrared Sensor Operation Available in or
More informationSN2005, SN2008 Sentry Circular Shallow Bowl Washfountain
cupc Certified Available with Air, Infrared or TouchTime Available in a or 36" Bowl Size Standard and Juvenile Height Model with Infrared, TouchTime Pushbutton and Piezo or Air (hand) are ADA/TAS Compliant
More informationWF2613 Classic Corner Washfountain with 9" Deep Bowl
cupc Certified Available in a 54" Bowl Size 9" Deep Bowl, Designed for Heavy Duty Hand Washing Reliable Foot, Air, TouchTime or Infrared Activations Specifications Size and Capacity Accommodates three
More informationMechanical Inspection Plumbing
0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,
More informationPlumbing Guidelines 2012 IBC/ANSI A
Plumbing Guidelines 2012 IBC/ANSI A117.1-2009 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms and bathing facilities. It is not intended to replace
More informationCLINICAL SERVICES ADMINISTRATION (214)
CLINICAL SERVICES ADMINISTRATION (214) 1 - M EDICAL SERVICE AREA 1 - OFDC2 - Interview Room A5075 Dispenser, Soap, Disposable 1 VV Disposable soap dispenser. One-handed dispensing operation. Designed to
More informationSN2013, SN2033 Sentry Corner Shallow Bowl Washfountains
cupc Certified Available with Infrared, Air or TouchTime 54" Bowl Size Wall-Mounted or Floor-Mounted Standard and Juvenile Height with Air (hand), TouchTime Pushbutton and Piezo or Infrared are ADA/TAS
More informationDESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
More informationSN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain
SN2003, SN2023, SN2004, SN2024 cupc Certified Reliable Push Button Activated Air Metering, Infrared, or TouchTime Control Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height
More informationWF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains
cupertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Reliable foot, air, Touchtime or Infrared activations
More informationPlumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1
Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms
More informationTRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION
SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationSN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain
SN2003, SN2023, SN2004, SN2024 cupc Certified Available with Infrared, Air or TouchTime Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height Models and Juvenile Height 54"
More informationTDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain
cupc Certified ADA Compliant Suitable for Heavy-Duty Hand Washing Reliable Air, TouchTime or Infrared Activations Vandal Resistant - Easy to Clean Three Different Heights (Including Juvenile and Intermediate
More information500H TOILET VESSEL LAVATORY FREESTANDING TUB
500H TOILET VESSEL LAVATORY FREESTANDING TUB NEOREST 500H NEOREST 500H DUAL FLUSH TOILET MS952CUMG Tornado Flush siphon jet flushing system, ultra high-efficiency (1.0GPF/3.8LPF and 0.8GPF/3.0LPF) CeFiONtect
More informationBRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,
More informationWF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains
cupertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Foot, ir Metering, Infrared or TouchTime ontrol Specifications
More informationB. Shop Drawings: Include diagrams for power, signal, and control wiring.
SECTION 224213.13 - COMMERCIAL WATER CLOSETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPlatinum Features - Multi Section
Platinum Features - Multi Section Construction 2 X 4 sidewalls 16" on center 2 X 3 interior walls 24" on center 2 x 4 marriage line walls 24 " on center 2 X 6 floor joist 16 on center - 28 wides / 2 X
More informationDESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.
PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
More informationFL-2H, FL-2L Frequency Lavatory System FL-Series
& TAS Compliant (lower or "concave" stations only) Patented Molded One-Piece Design with Integral Bowls Constructed of Terreon or Terreon RE Solid Surface Material Access Panel and Transition Cover Enclosure
More informationSECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:
SECTION 15440 PART I - GENERAL 1.01 WORK INCLUDED A. Types of plumbing fixtures required for the project include the following: 1. Water Closets 2. Urinals 3. Lavatories 4. Mop Sink 5. Sinks 6. Electric
More informationInstallation & Operation Manual
Installation & Operation Manual Patient Care Unit WH-2400 Table of Contents Pre-Installation Information...3 Physical Dimensions...4 Rough-In Dimensions...7 Checking Contents...8 Required Installation
More informationWF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains
cupertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Foot, ir Metering, Infrared or TouchTime ontrol Specifications
More informationWF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains
cup ertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Reliable Foot, ir, TouchTime or Infrared ctivations
More informationWF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains
cup ertified vailable in Semi-ircular or ircular with 9" Deep owls Designed for Heavy Duty Hand Washing vailable in 5 or 36" Diameter owl Size Foot, ir Metering, Infrared, or TouchTime ontrol Specifications
More informationBRADLEY HALO EMERGENCY PLUMBING FIXTURES
BRADLEY HALO EMERGENCY PLUMBING FIXTURES Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash, ergonomic hand activation
More informationSPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER
SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER DESCRIPTION The SEF-18XY, Eyesaver faucet series combines a Gooseneck
More informationA. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationWAW-2311 WAW-2322 WAW SERIES LAVATORIES
COMMERCIAL PRODUCT GUIDE PLUMBING FIXTURES & ACCESSORIES Willoughby Industries has manufactured commercial grade stainless steel and solid surface plumbing products for more than 65 years. Our focus is
More informationPLUMBING FIXTURES Reserved
CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower
More informationManufacturer of Healthcare and Therapy Products. care-ware
Manufacturer of Healthcare and Therapy Products care-ware Whitehall Manufacturing, a division of Acorn Engineering Company, is based on the same principles set by its parent company to engineer the best
More informationResidential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.
Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Units Accessibility s rev. 11/12/12 Unit 2005 CT State Building Code () A117.1 (2003) **indicates CT Amendment to
More informationBathroom remodeling Dictionary
Bathroom remodeling Dictionary Anti Scald Pressure balance Valve Allows water temperature to stay constant even with changes in the water pressure. Backsplash Vertical extension to a counter which will
More information2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS
City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY
More informationExpress Lavatory System SS-Series
P L U M I N G F I X T U R E S Model SS-3N/IR3 (attery Infrared Control) ADA, ANSI and UFAS Compliant Serves One to Three Users at a Time Continuous owl is constructed of Vandal Resistant Terreon Solid
More informationD & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.
D & L SUPPLY and MFG. 448 WEST MAIN ST. AUBURN,WA 98001 1(800)872-9577 24 HOUR FAX (206)939-6908 A.D.A. SOLUTIONS FROM THE PARTS PEOPLE A.D.A. AND YOU The Americans with Disabilities Act (A.D.A.), signed
More informationSS-1N Express Lavatory System SS-Series
ADA, ANSI, TAS and UFAS Compliant Constructed of Vandal Resistant-Terreon Solid Surface Material Available in 29 Colors Choose from a Terreon Sprayhead or a Bowl Only Model with Your Choice of Faucet Optional
More informationSAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET
SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials,
More informationPLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS
The Design Guidelines, which follow, are intended to supplement the Educational Specifications and State Requirements for Educational Facilities (SREF). Note: All fittings shall be installed by no less
More informationASI Guide Specification
SECTION 10 2800 TOILET ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Provide toilet accessories with attachment hardware and rough-in frames as required for complete, operational installation. B. Section
More informationPLUMBING REQUIREMENTS
PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all
More informationA. This Section includes the following emergency plumbing fixtures:
Page 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain
cupc Certified ADA and TAS Compliant Suitable for Heavy Duty Hand Washing Reliable Air, TouchTime or Infrared Vandal Resistant Easy to Clean Three Different s (Including Juvenile and Intermediate s) Specifications
More informationBATH PLANNING GUIDE CONTRACTOR MY CONTACT INFORMATION PROJECT TYPE PLANNING YOUR VISIT BUDGET INITIAL CONSULTATION
BATH PLANNING GUIDE Every great design project begins with a great plan. Whether you re starting a remodeling project or creating an entirely new space, success will depend largely on quality preparation.
More informationSelection Guide.
Selection Guide www.zurn.com SELECTION GUIDE Table of Contents Commercial Brass... 2-3 AquaSpec... 4-5 Tubular Brass... 6 Zurn Fixtures... 7 Introduction... 8 Understanding a Zurn One System Number...
More informationThe Water Efficiency Company. Vitreous China Fixtures
The Water Efficiency Company Vitreous China Fixtures A Reputation for Quality, Performance and Sustainability Long before LEED and the sustainability movement emerged, Sloan was developing and producing
More informationSpecial Requirements For Health Care Facilities
Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements
More informationElectrical Information
Electrical Information Breaker Panel 1: Service Type: Unreadable Panel Type: Unreadable Panel Number: Unreadable Manufacturer: Unreadable Amps: Unreadable Location: Storage Room Notes: Exterior Disconnect
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet
More informationSECTION PLUMBING
SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),
More informationIPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.
IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum
More informationSERIES II at TIVOLI PLANS 1-4
SERIES II at TIVOLI PLANS 1-4 Series II Features List Sure, you say, these model homes look great, but how much will all the extras cost me? Well, chances are a lot of those extras aren t. They re included,
More informationMATERIALS Traps TRAPS. No. IPC IRC Description
MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture
More informationAV30 Advocate Lavatory System AV-Series
Soap, water and hand dryer, unique all-in-one patent pending design Includes infrared, high speed, dual-sided hand dryer at each hand washing station Includes large capacity, top-fill, infrared soap dispenser,
More informationPLUMBING FIXTURES CHAPTER 27
CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,
More information1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."
Page 224000-1 SECTION 224000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSCOPE OF WORK. 506 N. Chadbourne Ave, San Angelo, TX. 1. Build and outfit kitchen are in accordance with established drawing
SCOPE OF WORK 506 N. Chadbourne Ave, San Angelo, TX Contractor shall be required to provide labor, supervision, and equipment to build a small multipurpose kitchen and Americans with Disabilities Act (ADA)
More informationUnit # E ± 1,200 SF Width ± 20' Depth ± 60'
Lease Outline Drawing ±60' Lease Line Sunnymead Plaza 24907 Sunnymead Blvd., Unit # E, Moreno Valley, CA 92553 Unit # E ± 1,200 SF Width ± 20' Depth ± 60' Plans produced by: ID Plans 6/13/2017 (813) 657-2545
More informationModels: FM FM WARNING
Installation Stainless Steel Blowout Urinal Models: 923-8000 923-8001 923-8002FM 923-8003FM Table of Contents Overview...2 Pre-Installation Information...3 Installation Instructions...4-7 Cleaning Instructions...7
More informationTHE INSIDE STORY EXTERIOR VARIETY KITCHENS TO SAVOR PERSONALIZING OPPORTUNITIES LUXURIOUS BATHS WATER AND ENERGY SAVERS
TopaZ COLLECTION FEATURES LIST Sure, you say, these model homes look great, but how much will all the extras cost me? Well, chances are a lot of those extras aren t. They re included, as a quick look at
More informationParadise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.
Electrical Information Breaker Panel 1: Service Type: Not Listed Panel Type: Not Listed Panel Number: Not Listed Manufacturer: Not Listed Amps: Not Listed Location: Rear of Storage Room Notes: Unlabeled
More informationAPPENDIX J ILLUSTRATIONS
The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely
More informationBARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327
BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327 BEFORE YOU BEGIN INSTALLER HAZARD NOTIFICATION WARNING: Risk of injury or water damage. Contents of vessel under pressure can cause severe
More informationAMBER COVE. We measure our success. San Jacinto Division. By the size of your smile!
We measure our success By the size of your smile! San Jacinto Division by Skyline Standard Features Interior 8ft Sidewalls with Cathedral Ceiling ½ Tape & Texture Drywall Throughout Hand-Finished Knock-Down
More informationFL-1H, FL-1L Frequency Lavatory System FL-Series
D & TS Compliant (lower or "concave" stations only) Patented Molded One-Piece Design with Integral Bowl Constructed of Terreon or Terreon RE Solid Surface Material ccess Panel and Transition Cover Enclosure
More informationTown Square S Collection
Town Square S Collection We ve Set the Standard Yet Again American Standard is where life happens, improving everyday living in and around your kitchen and bathroom. Our product solutions blend inviting
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationParadise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth
Electrical Information Breaker Panel 1: Service Type: 120/208 Panel Type: Type 1 Panel Number: 383-21 Manufacturer: Challenger Amps: 200 Location: Near Exit Door of Main Space Notes: Breaker Panel 2: Service
More informationStandard Features List
Standard Features List Sure, you say, these model homes look great, but how much will all the extras cost me? Well, chances are a lot of those extras are not. They re included, as a quick look at our Standard
More informationDESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.
PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Utilize wall hung toilet room fixtures. Urinals for handicapped may be
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards
Date Description of Change Pages / Sections Modified ID 8/5/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This section applies to Plumbing for campus institutional facilities. A. Purpose: Yale University
More informationMoen Commercial Products Eco-Performance Product Guide
Moen Commercial Products Eco-Performance Product Guide Learn how the use of MOEN Commercial Products What is LEED? The Leadership in Energy and Environmental Design (LEED) Green Building Rating System
More informationFAUCET PARTS - EXPLODED VIEW Model: K-59
FAUCET PARTS - EXPLODED VIEW Model: K-59 Swivel Gooseneck Spout 55/64-27 Male Thread OPTIONAL Low-Flow Aerator.5 GPM K-08 Aerator 2 GPM Flow "O" Rings { Back Plate Washer Nut Body NOTE: Hot Stem is LEFT
More informationUnit # H ± 2,000 SF Width ± 25' Depth ± 80'
±80' Lease Line Lease Outline Drawing Sunnymead Plaza 24907 Sunnymead Blvd., Unit # H, Moreno Valley, CA 92553 Unit # H ± 2,000 SF Width ± 25' Depth ± 80' Unit # H Plans produced by: ID Plans 6/13/2017
More informationAging-In-Place Remodeling Checklist
5867 West Hidden Springs Dr. Hidden Springs, Idaho 83714-9405 (208) 229-2553 Fax (208) 229-2554 Idaho Registration No. RCE-91 www.chuckmillerconstruction.com Aging-In-Place Remodeling Checklist Have you
More informationDIVISION 10 SPECIALTIES
DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02
More informationJAMES P. KISSANE, ARCHITECT
UNISEX RESTROOM 6" X 9" UNISEX H.C. RESTROOM SIGN; BLUE NOTE: THE FASTENING HARDWARE FOR THE WALL BRACKETS FOR THE AND THE URINAL AND GRAB BARS MUST BE ABLE TO SUPPORT A 300 LB. WEIGHT. CONTRACTOR IS REQUIRED
More informationSECTION 9 ~ NECROPSY DISSECTION TABLES
SECTION 9 ~ NECROPSY DISSECTION TABLES SECTION INDEX NECROPSY TABLES... PAGE Downdraft Necropsy Station... 2-3 Small Necropsy Stations... 4-9 Medium Necropsy Station... 10-11 Standard Necropsy Table...
More informationInstallation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents
LC800 Patient Care Unit, 47", Fixed Water Closet Table of Contents Pre- Information.................2 Supplies Required........................2 Step 1: Water Closet......................3 Step 2: LC800
More informationInstallation. Please keep this manual for future reference.
Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning
More informationTOILET SYSTEM - DESCRIPTION AND OPERATION
TOILET SYSTEM - DESCRIPTION AND OPERATION 1. General The toilet system is provided for the convenience of the passengers and crew. It comprises three individual subsystems - FWD, MID and AFT. Each subsystem
More informationINTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR EARLY-CLOSURE REPLACEMENT FLAPPERS OR EARLY-CLOSURE REPLACEMENT FLAPPER WITH MECHANICAL ASSEMBLIES IAPMO
More informationUnit # 1038 ± 900 SF Width ± 15' Depth ± 60'
±60' Lease Line Lease Outline Drawing Needles Towne Center 1004 E. Broadway St.,, Needles, CA 92363 ± 900 SF Width ± 15' Depth ± 60' Plans produced by: ID Plans 6/16/2017 (813) 657-2545 C 2017 Site map
More informationPipe Sizing Table. Hydraulic Load Served (fixture units)
MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3
More informationHelping create a better healthcare experience.
Healthcare Solutions Helping create a better healthcare experience. At Delta, we believe there is a better way for healthcare professionals and their patients to work with water. With decades of experience
More informationAV60 Advocate Lavatory System AV-Series
Soap, water and hand dryer, unique all-in-one patent pending design Includes infrared, high speed, dual-sided hand dryer at each hand washing station Includes large capacity, top-fill, infrared soap dispenser,
More informationGen 4.5 New Build Palettes
SpringHill Suites New Build This Master Specification Document, as an Instrument of Service, is provided in confidence, for use in preparing final construction specifications for a Marriott CFRST Project.
More information