SC-LLC-200 LEAD/LAG CONTROLLER INSTALLATION INSTRUCTIONS
|
|
- Gerard Austin
- 5 years ago
- Views:
Transcription
1 LEAD/LA CONTOLLE INSTALLATION INSTUCTIONS
2 INTODUCTION The from Specified Controls is a versatile, AC powered lead/lag controller offering true dual stage control to balance the operating run time between HVAC equipment as well as other redundant devices. The controller has dedicated terminals for AC power, 2 inputs and 2 outputs. LEDs provide visual indication for power and output status. SEQUENCE OF OPEATION When 24 Volt power is first applied to the AC terminals 7and 8 on the, and output contacts remain open. When 24 Volts is applied to input terminal 1, output contacts go closed and contacts remain open. When 24 Volts is removed from terminal 1 for at least 10 seconds, output contacts open. When 24 Volts is reapplied to terminal 1, output contacts remain open and output contacts go closed. The lead/lag sequence is reversed every time 24 Volts is removed from terminal 1 for more than 10 seconds and then reapplied. In a dual stage application, 24 Volts applied to terminal 2 will close the lag output contacts. As long as 24 Volts is maintained on terminal 1, the lag output can be cycled on and off. The Lead/Lag Controller must be powered from the same 24 Volts as control circuit or a relay will be required. WIIN DIAAMS The wiring diagrams illustrated in this installation manual represent a sampling of the many ways the can be applied for lead/lag control. The is an operating controller only and depending on the application, it is the responsibility of the installer to verify that the complies with all electrical and/or plumbing codes. SPECIFICATIONS Input: Frequency: Contact ating: PC Board Dimensions: 24 VAC 60/60 Hz VAC 3.25 W x 5.5 H Mounted on Snap-Track Controller With -ME with metal enclosure Optional Enclosures: -WPE with weather-proof plastic enclosure 5351 East Thompson oad, Suite 128, Indianapolis, IN
3 LEAD/LA CONTOLLE STAND ALONE APPLICATIONS TYPICAL WIIN DIAAMS
4 WIIN DIAAM USIN LEAD/LA CONTOLLE WITH SINLE-STAE COOLIN UNITS IN PAALLEL LEAD/LA CONTOL C SINLE-STAE STAT 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
5 WIIN DIAAM USIN LEAD/LA CONTOLLE WITH SINLE-STAE COOLIN UNITS IN PAALLEL WITH UPSTAIN LEAD/LA CONTOL C MULTI-STAE STAT 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
6 WIIN DIAAM USIN LEAD/LA CONTOLLE FO 2 PUMP SYSTEM WITH A FLOW SWITCH TO TIE LEAD/LA LEAD/LA CONTOL TANSFOME LINE FLOW SWITCH PUMP 2 ELAY PUMP CONTOLLE 24 V COIL Y-1 24 V COIL Y-1 NC C NO NC C NO PUMP 1 PUMP 2 PUMP 1 ELAY 120V / 240V POWE 120V / 240V POWE 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
7 WIIN DIAAM USIN LEAD/LA CONTOLLE FO 2 PUMP SYSTEM WITH A ELAY TO TIE LEAD/LA LEAD/LA CONTOL TANSFOME LINE PUMP 2 ELAY PUMP CONTOLLE 24 V COIL Y-1 24 V COIL Y-1 NC C NO NC C NO PUMP 1 PUMP 2 PUMP 1 ELAY 120V / 240V POWE 120V / 240V POWE 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
8
9 LEAD/LA CONTOLLE USED WITH SC-SC-TK-400 TWINNIN AND PAALLELIN KIT TYPICAL WIIN DIAAMS
10 WIIN DIAAM USIN LEAD/LA CONTOLLE AND SC-SC-TK-400 TWINNIN KIT FO COOLIN LEAD/LA SINLE-STAE STAT SC-SC-TK-400 LEAD/LA CONTOL THEMOSTAT TEMINALS HVAC 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
11 WIIN DIAAM USIN LEAD/LA CONTOLLE AND SC-TK-400 TWINNIN KIT FO COOLIN LEAD/LA WITH UPSTAIN MULTI-STAE STAT SC-TK-400 LEAD/LA CONTOL THEMOSTAT TEMINALS HVAC 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
12 WIIN DIAAM USIN LEAD/LA CONTOLLE AND SC-TK-400 TWINNIN KIT FO HEATIN LEAD/LA SINLE-STAE STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
13 WIIN DIAAM USIN LEAD/LA CONTOLLE AND SC-TK-400 TWINNIN KIT HEATIN LEAD/LA WITH UPSTAIN MULTI-STAE STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
14 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT FO HEATIN AND COOLIN LEAD/LA SINLE-STAE STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL (HEATIN) LEAD/LA CONTOL (COOLIN) 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
15 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT FO HEATIN AND COOLIN LEAD/LA WITH UPSTAIN MULTI-STAE STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL (HEATIN) LEAD/LA CONTOL (COOLIN) 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
16 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT FO 1 HEAT / 1 COOL HEAT PUMP HEAT PUMP STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
17 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT FO 1 HEAT / 1 COOL HEAT PUMP WITH UPSTAIN HEAT PUMP STAT THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
18 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT AND Y-2 DPDT ELAY FO 2 HEAT / 1 COOL HEAT PUMP HEAT PUMP STAT W THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL W W NC C NO NC C NO 5351 East Thompson oad, Suite 128, Indianapolis, IN 46237
19 WIIN DIAAM USIN LEAD/LA CONTOLLES AND SC-TK-400 TWINNIN KIT FO 2 HEAT / 1 COOL HEAT PUMP WITH UPSTAIN (Auxiliary / EH Heat Work Together) HEAT PUMP STAT W THEMOSTAT TEMINALS SC-TK-400 LEAD/LA CONTOL 5351 East Thompson oad, Suite 128, Indianapolis, IN SC
CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins
P-6 Installation and Operation Instructions 3 Heat / 2 ool Heat Pump with Fossil Fuel option Auto hangeover - ooling Priority or Majority Wins Sequence of Operation: Each zone damper is controlled by its
More information45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:
SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart
More informationTZ-3 TotalZone Zone Control Panel
TZ-3 TotalZone Zone Control Panel FEATUES PODUCT DATA APPLICATION The TZ-3 TotalZone Zone Control Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment. It controls 2
More informationInstallation Instructions
HHK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers! IMPOTANT: The instructions included with this heater kit are for installations
More informationWiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.
THE EEN Z NE Z EE THE NE N Sequence of Operation: The reen Zone Z-300-HPS is a residential / light commercial zone control system that allows a single HVA unit to have up to three separate zones. Each
More informationLOW VOLTAGE CONTROL CIRCUIT WIRING
INSTALLATION INSTUTIONS LOW VOLTAE ONTOL IUIT WIIN MODELS W**A W**L W**A*D W**L*D WA*S Bard Manufacturing ompany, Inc. Bryan, Ohio 4506 Since 94...Moving ahead just as planned. Manual : 00-507B Supersedes:
More information50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM
21M51U-843 WIIN AND CONFIUATION INTEATED HOT (LINE) TYPICAL WIIN DIAAM 120 VAC NEUTAL (LINE) 24 VAC CLASS II TANSFOME TH 24 VAC T COOL PAK HEAT LO HEAT HI LINE XFM EAC HUM CICU- LATO BLOWE HUMIDIFIE (OPTIONAL)
More informationOwner s Guide. TrueIAQ Digital IAQ Control
Owner s uide TrueIAQ Digital IAQ Control 69-2072-09 Table of contents User Information About TrueIAQ... 1 Operation... 2 Display screen reference... 3 Adjusting IAQ settings Changing humidifier settings...
More informationInstaller s Guide ACONT200AN11AA 1 Heat (Gas, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 Wire Hookup
11-HD03D1-3 Available in French Canadian (FC) Installer s uide ACONT200AN11AA 1 Heat (as, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 ire Hookup ALL phases of this installation must comply with
More informationTCONT800AS11AA Touch Screen Programmable Comfort Control
TCONT800AS11AA Touch Screen Programmable Comfort Control 18-HD25D18-1 APPLICATION INSTALLATION INSTUCTIONS The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating
More informationACONT800AS11AA Touch Screen Programmable Comfort Control
ACONT800AS11AA Touch Screen Programmable Comfort Control 11-HD02D8-3 APPLICATION INSTALLATION INSTUCTIONS The ACONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating and
More informationTCONT800AS11AA Touch Screen Programmable Comfort Control
TCONT800AS11AA Touch Screen Programmable Comfort Control 18-HD25D18-3 APPLICATION INSTALLATION INSTUCTIONS The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating
More informationASYSTAT625A Humidity Control
ASYSTAT65A Humidity Control INSTALLE S GUIDE APPLICATION Humidity Control The humidity control provides automatic low voltage control of humidifiers in central heating and cooling equipment for both humidification
More informationTHERMOSTATS & CONTROLLERS
THETATS & CONTOLLES T70 SEIES POAABLE COEIAL THETATS AND W70 CONTOLLE T70, W70 SEIES DESCIPTION The Honeywell T70 Commercial Programmable Thermostat controls VAC single zone heating, ventilating and air
More informationWARNING CAUTION 50T INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS. Integrated Furnace Control
50T35-743 Integrated Furnace Control INSTALLATION INSTUCTIONS FAILUE TO EAD AND FOLLO ALL INSTUCTIONS CAEFULLY BEFOE INSTALLIN O OPEATIN THIS CONTOL COULD CAUSE PESONAL INJUY AND/O POPETY DAMAE. DESCIPTION
More informationAutomatic Digital Humidifier Control
Automatic Digital umidifier Control Safety and Installation Instructions EAD COMPLETE INSTALLATION INSTUCTIONS AND TEMPLATE BEFOE STATING. WANING ATTENTION INSTALLE: This product must be installed by a
More informationT8034C Heating/Cooling Thermostats
T8034C Heating/Cooling Thermostats INSTALLATI INSTUCTIS APPLICATI These T8034C Thermostats control 4 to 30 Vac singlestage heating-cooling systems. An spdt mercury switch makes (H) to on temperature fall
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTUTIONS LOW VOLTAE ONTOL IUIT WIIN Models: W**A W**AD WA*S* W**L WL*S* Bard Manufacturing ompany, Inc. Bryan, Ohio 06 www.bardhvac.com Manual No.: 00-8 Supersedes: 00-8B Date: -- Page of
More informationINSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `!
INSTALLATION GUIDE AAN & AEN Series - Manufactured Housing Electric Furnace. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with
More informationT8400C Electronic Thermostat
T8400 Electronic Thermostat INSTALLATION INSTUTIONS The T8400 provides single-stage, non-programmable temperature control for 24V heating-cooling systems with manual changeover from heat to cool. Heating
More information5+2 Day. up to HEAT COOL
Digital Thermostat residential THEMOSTAT T1050 5+2 Day POGAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 heat & 2 Cool Stages 4 Settings Per Day Self-prompting programming Auto changeover
More informationCOOL 1 FAN HEAT 1 START HERE - POWER THE DEVICES - GENERAL DIAGRAM POWERING THE LCBS CONNECT CONTROLLER BUILDING NAME CVAHU RTU NAME DATE COM COM COM
STAT HEE - POWE THE DEVICES - ENEAL DIAAM POWEIN THE CONNECT CONTOLLE H H C C Y3 -L Y3 -L POWE EXISTIN COOLIN TANSFOME FACTOY JUMPE POWE EXISTIN HEATIN TANSFOME CONNECT INFOMATION THIS IS A ENEAL TEMPLATE
More informationFeatures: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase
Starters and Contactors Definite Purpose Contactors Standard, Open Type Ampere Rating Coil Voltage No of Pole Voltage CR353AB2AA1GE 25 110-120 @ 50/60 Hz 2 600 CR353AC3AH1GE 30 24 VAC @ 50/60 Hz 3 600
More information* For complete installation instructions, see General IOM this piece was inserted within. Also available at Min. Mtg.
*! ANIN: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Manual: 200-393O Supersedes: 200-393N Date: 2-26-6 Page of 8 CONTENTS Shipping
More informationFresh Air Ventilation Kit
Fresh Air Ventilation Kit io-fav-06 io-fav-08 The Fresh Air Ventilation system is designed to introduce fresh air into a home through an intake damper controlled by a micro-processor logic panel. The io-fav
More information7-Day. Digital Thermostat. residential. & 2-cool
Digital Thermostat residential THEMOSTAT T1100FS 7-Day POAMMABLE up to 2-heat & 2-cool HEAT OOL HEAT PUMP ontrol up to 2 Heat & 2 ool Stages 7-Day Programmable 4 Settings/Day Auto hangeover 5 minute Built-In
More informationDescription/ Application
Form I-OPT-MH (2-16) Obsoletes Form I-OPT-MH (Version D.2) Installation of Multiple Heater Control, Options CL31 and CL32 Applies to: Models LDAP, UDAP, APD, UDAS, UDBP, UDBS, UEAS, F, B, V Description/
More informationINSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER
INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER BARD MANUFACTURING COMPANY Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-393C Supersedes: 2100-393B File: Volume III Tab
More informationOperator: Save these instructions for future use!
WHITE-ODES 1F89-11 Non-Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPEATION INSTUTIONS Operator: Save these instructions for future use! FAILUE TO EAD AND FOLLOW ALL INSTUTIONS
More informationTHERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration
INDEX THERMOSTATS 126 l (s) Description Page(s) EMERSON BI BLUE 12" TOUCHSCREEN 1F97-1277... Wiring Diagrams / Configuration... 126 131 1F95-1280 / 1F95-1291... Wiring Diagrams / Configuration... 128 131
More informationAR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501
ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501 AR822-II AR861-2II AR861-3II (Corporate Sales) 85 Middle Road Dunkirk, NY 14048 www.argoindustries.com An ISO 9001-2000 Certified Company P/N
More informationTZ-4 TotalZone Zone Control Panel
TZ-4 TotalZone Zone Control Panel FEATURES PRODUCT DATA APPLICATION The TZ-4 TotalZone Zone Control Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment. It controls,
More informationSCCG50 & SCCP50 Service Parts
SCCG0 & SCCP0 Service Parts This is the illustrated parts list for the SCCG0M and the SCCP0M esidential Ice Machines hen ordering a service part, always refer to the complete model number of the equipment
More informationGeniSys 120V. Model Description / Applications. Advanced Burner Control
PATS & ACCESSOIES GeniSys 120V Model 75 Advanced Burner Control Description / Applications The Beckett GeniSys TM Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial
More informationTUBE HEATER TROUBLESHOOTING GUIDE
TUBE HEATE TOUESHOOTING GUIDE MODELS: HLV Series Tube Heaterer THESE HEATES MUST BE INSTALLED AND SEVICED B TAINED GAS INSTALLATION AND SEVICE PESONNEL ONL. EAD AND UNDESTAND ALL INSTUCTIONS THOOUGHL BEFOE
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More informationHD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.
HD COMMUNICATOR Next Generation Communications for Railway Networks Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair. Echelon & Ethernet connectivity.
More informationINSTALLATION/OPERATING INSTRUCTIONS HEAT-TROL Elite Series. HWE-Motorized Valve
INSTALLATION/OPEATING INSTUCTIONS HEAT-TOL Elite Series HWE-Motorized Valve How Water eset Control with Setback and Boost For Motorized Valve Operation The HWE-Motorized Valve (HWE-MOV) establishes ambient
More information5600 series. Low Energy Power Operator
5600 series Introduction The 5600 Series, a member of the POWERMATIC Family of Operators, offers functionality and control at an affordable price. Ideal for retrofit applications, the 5600 Series converts
More informationModel CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B
Model Z-4 Installation and Operating Instructions FOM 2045-2 1306 2013 White-odgers by Permission 37-6864B Z-4 ZONIN SSTM FATUS Purge Override Button Adjustable Second Stage Timer System Mode Indicator
More informationPAGE DESCRIPTION 01 SITE OVERVIEW & SCHEDULES ZONE 1 CONTROL DIAGRAM RCP-1 WIRING DIAGRAM (1 OF 2) 04 RCP-1 WIRING DIAGRAM (2 OF 2)
LA PALMA AVENUE YORBA LINDA, CA 9..000 PAE DESCRIPTION 0 SITE OVERVIEW & SCHEDULES 0 0 ZONE CONTROL DIARAM RCP WIRIN DIARAM ( OF ) 0 RCP WIRIN DIARAM ( OF ) 0 RCP TERMINAL BLOCK LAYOUT QTY DESCRIPTION
More informationR4140G Flame Safeguard Programming Controls
0G Flame Safeguard Programming Controls PODUCT DATA APPLICATION The 0G Flame Safeguard Programmers provide flameout protection plus automatic sequencing of the burner motor (blower), firing rate motor,
More informationW859F Economizer Control Packages
Economizer Control Packages 859F Economizer Control Packages are used with any Series 9 Modutrol IV Motor (M9XX) to modulate the outdoor and return air dampers for most economical operation of an economizer
More informationMAXIMUM UNIT AMPS MINIMUM WIRE SIZE
WIIN DIAAMS FM 58MVP VAIALE-APAIT NDENSIN AS FUNAE (have attached arrier single stage A & arrier Humidifier) Table 5 Electrical Data UNIT SIZE VLTS HETZ PHASE PEATIN VLTAE ANE Maximum* Minimum* MAXIMUM
More informationMini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater
Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to
More informationInstallation Instructions MODEL 8870
Installation Instructions MDEL 8870 These instructions are for connecting the Thermostat to the HVA equipment. To connect communication features, please reference the ommunicating Thermostat System Installation
More informationECAH SERIES ECM AIR HANDLER
ECAH SERIES ECM AIR HANDLER ECAH40 OPERATING MANUAL TABLE OF CONTENTS 1 GETTING STARTED... 3 2 ELECTRICAL CONNECTIONS... 3 3 DIMENSIONAL DATA... 4 4 PLUMBING... 5 4.1 OPEN SYSTEM... 5 4.2 CLOSED SYSTEM...
More informationSequence of Operations (excerpt)
Sequence of Operations (excerpt) Chilled Water System Consists of one (1) 600 cooling ton Trane CVHE 3 stage centrifugal chiller, with associated chilled water pumps, condenser water pumps and one (1)
More informationPCAH SERIES AIR HANDLER
PCAH SERIES AIR HANDLER PCAH2/PCAH3/PCAH4 OPERATING MANUAL 1 2 3 4 5 6 7 8 9 10 TABLE OF CONTENTS GETTING STARTED... 3 ELECTRICAL CONNECTIONS... 3 2.1 POWER CONNECTIONS... 3 2.1.1 PCAH2/PCAH3... 3 2.1.2
More informationUltraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual
Ultraviolet Monitoring System Part Numbers UV/MS-1 V3 UV/MS-2 V3 Installation And Operations Manual 2 System Description The Wyckomar UV Monitor measures true UV intensity at 254 nm, which is the effective
More informationZonex Systems Intelligent Fresh Air Ventilator Installation Instructions
Zonex ystems Installation Instructions Hotline (800) 228-2966 Visit Our Website www.zonexproducts.com The easy way to et Quotes Fast Part # IFAV introduction The Zonex ystems (PAT # IFAV) is a fresh air
More informationHZ322 TrueZONE. Zone Panel Professional Installation Guide
HZ3 TrueZONE Zone Panel Professional Installation uide 69-99-05 Installation uide TABE OF ONTENTS Specifications... Accessories... Mounting... Wiring... 3 Heat Pump... 6 Basic onfiguration... 7 Advanced
More informationTO DO IF YOU SMELL GAS
Installation and Operation Instructions Document 8001D Installation and Operation Instructions for Mini-Combo II (Models MCT, MCS) esidential Gas-Fired Space/ater Heater NOTE: This manual is to be used
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationEATON DFDAP-M / FDAP-M Remote Alarm Panels
O & M Manual IM05805008K O & M Manual IM05805008K TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER 1 2. ELECTRICAL CONNECTIONS 1 2.1 ELECTRICAL CHECKOUT INSTRUCTIONS 2 2.2 ELECTRIC ALARM
More informationSECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL
SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationInsert Manual. CL Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater
More informationINTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features
More informationInstaller s Guide 4FWCA, 4FWCF 18-GF01D1-2. Air Handlers Upflow / Horizontal Left or Right 2 5 Ton
18-GF01D1-2 Installer s Guide Air Handlers Upflow / Horizontal Left or ight 2 5 Ton 4FCA, 4FCF ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Important: This Document
More informationACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.
ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: ACM8 ACM8E - Fused Outputs - Fused Outputs ACM8CBE ACM8CB - PTC Outputs - PTC Outputs Rev. 092503 Overview: These units convert
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationLinear Heat Detection Cable - Monitor
/-Z/-G Digital Interface with Distance Display The module is designed to monitor a length of Digital (Non-resettable) Linear Heat Detecting Cable () for both Fire condition, and Fault status (open circuit).
More informationHEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03
Installation Instructions TSTATPS101 TSTATBBPS101 P374-1000 Digital Thermostat NTE: ead the entire instruciton manual before starting the installation. 6:03 68 Am AUT 70 L HEAT 67 o o HEAT L & HEAT PUMP
More informationMICROFLAT SERIES TYPES C.../U T X
MICOFLAT SEIES TYPES C.../U T X AUTOMATIC GAS BUNE CONTOL SYSTEMS FO GAS BUNES AND GAS BUNING APPLIANCES WITH O WITHOUT FAN APPLICATION This range of electronic gas burner control systems is suitable for
More informationHOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher
Micro Control Systems APPLICATION NOTE APP-006 5400-1 Division Drive Ft. Myers, FL 33905 USA (941)-694-0089 Fax (941) 694-0031 HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher Revision
More informationDesign & Installation for. Zonex Systems. System Zone Auto Changeover. System Zone Manual Changeover
Design & Installation for Zonex Systems System 2000 2-20 Zone Auto hangeover System 1000 2-7 Zone Manual hangeover Part #101ASIM ev. September 2003 TABLE OF ONTENTS System 2000 System Operation...1 omponents...1
More informationService Manual FAN COIL UNITS. Cancels: SM03-2 SM
Service Manual FAN OIL UNITS ancels: SM03- SM03-3 3-97 TABLE OF ONTENTS Page SAFETY ONSIDEATIONS...-3 INTODUTION...3 UNIT IDENTIFIATION...-3 PODUT OFFEIN...3 FAN MOTO SPEED TAPS...3 FA4A, FB4A, F4B, AND
More informationCommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits
CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,
More informationPS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option
Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationInstallation, operating and servicing instructions
09-5 - - 8-6 ENGLISH Single & Tri Phase Installation, operating and servicing instructions FANCAIS NEDELANDS EN ENGLISH FANCAIS WAnINGS Who should read these instructions Symbols ecommendations Applicable
More informationInstallation and Operating Instructions
MASTZON ZONIN SSTM 4 Zones For use with the 24V Damper Motors Model MZS4 Installation and Operating Instructions ontrolling our omfort oom By oom MASTZON ZONIN SSTM FATUS Purge Override Button System Mode
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationT8400C, T8401C and T8424C,D Electronic Thermostats
T8400, T840 and T844,D Electronic Thermostats PODUT DATA APPLIATION T8400 and T840 T844,D The T8400 and T840 Standard Electronic Thermostats provide single-stage, non-programmable temperature control for
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationModel A1600 Series Annunciator
Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationEnviroZone-4 & EnviroZone-2 Quick-Start Guide
EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTUCTIONS Models EBV 2-5 Ton Use ONL factory listed electric heaters. Variable Speed Safety Labeling and Signal ords Danger, arning and Caution The signal words DANGE, ANING and CAU- TION
More informationMulti-Position Air Handler with Hyrdonic Heat with X13 Motor HWCGxxX0A
INSTALLATION, OPEATION & MAINTENANCE MANUAL Multi-Position Air Handler with Hyrdonic Heat with X13 Motor HWCGxxX0A Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
More informationINTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTI / TABLE OF CTENTS Step One The LVCN 51 Series Continuous Relay Controller is a general purpose level controller which provides single tank level indication with dual relays and a repeater
More informationNON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this
Installation Manual NN-PAMMABLE THEMSTAT TSTAT < < Fig. 1 Non-Programmable Thermostat NTE: ead the entire instruction manual before starting the installation. A98193 SAFET NSIDEATINS ead and follow manufacturer
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationQ7800H Integrated Burner Control Subpanel
Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.
More informationMX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor
IM-MAH-0662403-11 November 2017 Installation Instructions MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency EM Motor TABLE OF ONTENTS
More informationResidential Fan Coil Units
esidential Fan oil Units Visit www.carrier.com Service Manual TABLE OF ONTENTS Page SAFETY ONSIDEATIONS... INTODUTION... UNIT IDENTIFIATION... PODUT OFFEIN...4 FAN MOTO SPEED TAPS...4 FA4A, FB4A, F4B,
More informationSQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD
E-1620 0509 SQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD Self-Contained & emote Models INSTALLATION & OPEATION INSTUCTIONS KEEP THIS MANUAL FO FUTUE EFEENCE Engineering and technical data are subject to change without
More informationInstallation and Operating Instructions
Visit www.carrier.com Non-Programmable Thermostat TSTATN(A,HP,2S)01- Installation and perating Instructions NTE: ead the entire instruction manual before starting the installation. This symbol indicates
More information38CKC, 38CKG, 38CKS, 38CKW 10 SEER Split System Air Conditioner
38K, 38K, 38KS, 38KW 10 Split System Air onditioner Visit www.carrier.com Installation and Start-Up Instructions NOTE: ead the entire instruction manual before starting the installation. This symbol indicates
More informationService Manual RESIDENTIAL FAN COIL UNITS. Cancels: SM03-4 SM
Service Manual ESIDENTIAL FAN OIL UNITS ancels: SM03-4 SM03-5 6-99 TABLE OF ONTENTS Page SAFETY ONSIDEATIONS... INTODUTION... UNIT IDENTIFIATION... PODUT OFFEIN...4 FAN MOTO SPEED TAPS...4 FA4A, FB4A,
More information100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4
Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MC3000 SERIES SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-452 Supersedes:
More informationINSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P
APATMENT FAN COIL UNIT FMA4X, FMA4P NOTE: ead the entire instruction manual before starting installation. These instructions must be read and understood completely before attempting installation. TA BLE
More informationInstruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules
Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.
More informationT8112 Programmable Thermostat
T8112 Programmable Thermostat FEATUES PODUCT DATA HEAT-OFF-COOL system switch. AUTO-ON fan switch. Separate programs for weekdays and weekends (5 day/2 day). Digital LCD display. Easy to program and install.
More informationRED DOT UNITS HEATER ONLY. Heaters PAGE 51
Heaters PAGE 51 R-254 & R-255 Auxiliary Heaters TRUCKS RECREATIONAL These auxiliary heaters are among the most versatile and maintenance free units Red Dot has ever built. Red Dot's round tube and fin
More informationWARNING DIAGNOSTIC GUIDE DIAGNOSTIC TESTS IMPORTANT ACTIVATING THE DIAGNOSTIC TEST MODE. DIAGNOSTIC: Saved Fault Codes. DIAGNOSTIC: Active Fault Codes
TECH SHEET - DO NOT DISCAD PAGE WANING Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS GVDM-26 DOMESTIC HOT WATER DESUPERHEATER PUMP MODULE KIT BMC, Inc. Bryan, Ohio 43506 Manual: 2100-546C Supersedes: 2100-546B Date: 4-18-16 Page 1 of 11 CONTENTS General... 3 Description...
More informationCommStat 4 Controller
CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with
More informationProduct Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS
Product Data TSTAT Thermostats Thermidistat TM Control BUILDER S THERMOSTAT * Standard Model (AC, HP) NON-PROGRAMMABLE THERMOSTAT * Standard Model (AC, HP, 2S) PROGRAMMABLE THERMOSTAT AND THERMIDISTAT
More information