ENTE CERTIFICAZIONE MACCHINE

Size: px
Start display at page:

Download "ENTE CERTIFICAZIONE MACCHINE"

Transcription

1 ENTE CERTIFICAZIONE MACCHINE Organismo di Certificazione e di Ispezione - unto GS Ente di Formazione n Laboratorio di rova ISO/IEC Test Report EN 14825:2013 COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 EN :2013+ EN ISO 4871:2009 EN :2013 EN :2013 EN :2013 Heat pump water heater March

2 Test Report Guangzhou Jinlun Electric Equipment Co.,Ltd Jinlun Technology zone Qidong Rd Huadong Town Huadu District Guangzhou City..R.China Heat pump water heater Standard: EN 14825:2013 COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 EN :2013+ EN ISO 4871:2009 EN :2013 EN :2013 EN :2013 repared For: Guangzhou Jinlun Electric Equipment Co.,Ltd Jinlun Technology zone Qidong Rd Huadong Town Huadu District Guangzhou City..R.China AGE 1 OF 24

3 Test Report No.: DEU(16)-12-X0703A-3 Order date: Client: Guangzhou Jinlun Electric Equipment Co.,Ltd Jinlun Technology zone Qidong Rd Huadong Town Huadu District Guangzhou City..R.China Test item: Identification / Type No.: Rating: Order content: Test specification: Heat pump water heater MD30D/MDS30D/MDY30D/MDN30D AC380V, 50Hz, 2.98kW ER test EN 14825:2013 COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 EN :2013+ EN ISO 4871:2009 EN :2013 EN :2013 EN :2013 Date of receipt: Test sample No.: lace of testing: Testing laboratory: Test result: Test by: LAB Guangzhou Deu Technology Testing Co., Ltd. Guangzhou Deu Technology Testing Co., Ltd. ass Detailed photo documentation see appendix to this report Reviewed by: Name/osition: Mandy Huang Date: Signature: Name/osition: Fego Liu Date: Signature: Condition of the test item at delivery: Test item complete and undamaged Legend 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor (ass) = passed a.m. test specification(s) F(ail) = tailed a.m. test specification AGE 2 OF 24

4 N/A = not applicable N/T = not tested This test report only relates to the a.m. test sample. Without permission of the test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. Test sample particulars... : Classification of installation and use... : Fixed appliance Type of the appliance... : Heat pump water heater Function of the appliance... : Space heating/water heater Heating season (heating function applicable)... : Average ossible test case verdicts: - test case does not apply to the test object...: N/A - test object does meet the requirement...: (ass) - test object does not meet the requirement...: F(Fail) General product information The appliance is heat pump water heater which installed at outdoor. The appliance can provide space heating. The appliance does not incorporated water pump. General remarks "(see remark #)" refers to a remark appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. General descriptions Remarks: Brief description of the tested sample(s): Complete test was conducted on MD30D. MDS30D/MDY30D/MDN30D are serial products. They belong to the same circuit type except the difference in power, load capacity and the dimension. Testing results summary The appliances meet the requirement of the seasonal space heating energy efficiency in COMMISSION DELEGATED REGULATION (EU) No 813/2013. According to COMMISSION DELEGATED REGULATION (EU) No 811/2013 with regard to the energy labelling of space heater, the seasonal space heating energy efficiency class of the unit is A+. AGE 3 OF 24

5 Model list: Model Rated voltage Refrigerant/charge MD30D/MDS30D/MDY30D/MDN30D 220V/1N/50Hz, 380V/3N/50Hz R417A/2200KG Compressor Condenser Evaporator Manufacturer Model type Rated capacity Rated input Manufacturer Model type Heat exchanger Manufacturer Fin type Fin spacing Tube pitch x row pitch ip specification COELAND ZW34KA-TF KW 2.98KW Hangzhou Shenshi Energy save technical Co., Ltd KOC-TG-2 Tube In Tube Heat Exchanger Foshan Nanhai minghuang cooling Equipment Co., Ltd Copper tube aluminum foil type fin 2.0mm 25mm φ9.52 internal thread pipe Dimension *349.32*650 Fan motor Manufacturer Model type specification Foshan Nanhai Songgang Junfeng electric Co., Ltd YDK W AGE 4 OF 24

6 Rating labels and marking: Remark: other models rating label is identical to the representative rating label except for model name. AGE 5 OF 24

7 EN COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 Clause Requirement - Test Result - Remark Verdict COMMISSION REGULATION (EU) No 813/2013 Article 1 Subject matter and scope 1 This Regulation establishes ecodesign requirements for the placing on the market and/or putting into service of space heaters and combination heaters with a rated heat output heater 400 kw including those integrated in packages of space heater, temperature control and solar device or packages of combination heater, temperature control and solar device as defined in article 2 of Commission Delegated Regulation (EU) No 811/ This Regulation shall not apply to: (a) heaters specifically designed for using gaseous or liquid fuels predominantly produced from biomass; (b) heaters using solid fuels; (c) heaters within the scope of Directive 2010/75/EU of the European arliament and of the Council; (d) heaters generating heat only for the purpose of providing hot drinking or sanitary water; (e) heaters for heating and distributing gaseous heat transfer media such as vapor or air; (f) cogeneration space heaters with a maximum electrical capacity of 50 kw or above. (g) heat generators designed for heaters and heater housings to be equipped with such heat generators placed on the market before 1 January 2018 to replace identical heat generators and identical heater housings. The replacement product or its packaging shall clearly indicate the heater for which it is intended. N/A Article 3 Ecodesign requirements and timetable 1 The ecodesign requirements for heaters are set out in Annex II. 2 Each ecodesign requirement shall apply in accordance with the following timetable: AGE 6 OF 24

8 EN COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 Clause Requirement - Test Result - Remark Verdict (a) from 26 September 2015: (i) heaters shall meet the requirements set out in Annex II, points 1(a), 3 and 5; (ii) combination heaters shall meet the requirements set out in Annex II, point 2(a); (a) from 26 September 2017: (i) electric space heaters, electric combination heaters, cogeneration space heaters, heat pump space heaters and heat pump combination heaters shall meet the requirements set out in Annex II, point 1(b); (ii) combination heaters shall meet the requirements set out in Annex II, point 2(b); (a) from 26 September 2018 heaters shall meet the requirements set out in Annex II, point 4(a). 3 Compliance with ecodesign requirements shall be measured and calculated in accordance with the requirements set out in Annex III. Annex II Ecodesign requirements N/A 1 Requirements for seasonal space heating energy efficiency (a) From 26 September 2015 the seasonal space heating energy efficiency and useful efficiencies of heaters shall not fall below the following values: - Heat pump space heaters and heat pump combination heaters, with the exception of lowtemperature heat pumps: 100% - Low-temperature heat pumps: 115% N/A (b) From 26 September 2017 the seasonal space heating energy efficiency and useful efficiencies of heaters shall not fall below the following values: - Heat pump space heaters and heat pump combination heaters, with the exception of lowtemperature heat pumps: 110% - Low-temperature heat pumps: 125% N/A 2 Requirements for water heating energy efficiency N/A (a) From 26 September 2015 the water heating energy efficiency of combination heaters shall not fall below the following values: N/A AGE 7 OF 24

9 EN COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 Clause Requirement - Test Result - Remark Verdict Declared load profile Water heating energy efficiency 3XS XXS XS S M L XL XXL 3XL 4XL 22% 23% 26% 26% 30% 30% 30% 32% 32% 32% - (a) From 26 September 2017 the water heating energy efficiency of combination heaters shall not fall below the following values: N/A Declared load profile Water heating energy efficiency 3XS XXS XS S M L XL XXL 3XL 4XL 32% 32% 32% 32% 36% 37% 38% 60% 64% 64% - 3 Requirements for sound power level From 26 September 2015 the sound power level of heat pump space heaters and heat pump combination heaters shall not exceed the following values: 54 db Rated heat output 6 kw 6 kw < Rated heat output 12 kw 12 kw < Rated heat output 30 kw 30 kw < Rated heat output 70 kw - indoor outdoor indoor outdoor indoor outdoor Indoor outdoor 60 db 65 db 65 db 70 db 70 db 78 db 80dB 88dB 4 Requirements for emissions nitrogen oxides N/A 5 Requirements for product information N/A From 26 September 2015 the following product information on heaters shall be provided: (a) the instruction manuals for installers and endusers, and free access websites of manufacturers, their authorized representatives and importers shall contain the following elements: N/A N/A AGE 8 OF 24

10 EN COMMISSION REGULATION (EU) No 813/2013 COMMISSION DELEGATED REGULATION (EU) No 811/2013 Clause Requirement - Test Result - Remark Verdict - For heat pump heaters and heat pump combination heaters, the technical parameters set out in Table 2, measured and calculated in accordance with Annex III; - Any specific precautions that shall be taken when the heater is assembled, installed or maintained; - Information relevant for disassembly, recycling and/or disposal at end-of-life; N/A N/A N/A Annex III Measurements and calculations COMMISSION DELEGATED REGULATION (EU) No 811/2013 Annex II Energy efficiency classes 1 Seasonal space heating energy efficiency classes The seasonal space heating energy efficiency class of a heater, with the exception of lowtemperature heat pumps and heat pump space heaters for low-temperature application, shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 1. The seasonal space heating energy efficiency class of a low-temperature heat pumps and a heat pump space heaters for low-temperature application shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 2. The seasonal space heating energy efficiency of a heater shall be calculated in accordance with point 3 and 4 of Annex VII, for heat pump space heaters, heat pump combination heaters and lowtemperature heat pumps under average climate conditions. N/A 2 Water heating energy efficiency classes N/A The water heating energy efficiency class of a combination heater shall be determined on the basis of its water heating energy efficiency as set out in Table 3. The water heating energy efficiency of a combination heater shall be calculated in accordance with point 5 of Annex VII. N/A N/A AGE 9 OF 24

11 Information requirements for heat pump space heaters and heat pump combination heaters Models: Air to water heat pump: Water to water heat pump: Brine to water heat pump: Low-temperature heat pump: Equipped with a supplementary heater: Heat pump combination heater: MD30D arameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low-temperature application. arameters shall be declared for average climate conditions. Item Symbol Value Unit Item Symbol Value Unit Rated heat output rated 2.98 kw Declared capacity for heating for part load at indoor temperature 20 C and outdoor temperature T j yes No No No No No Seasonal space heating energy efficiency T j = -7 C dh 2.53 kw T j = -7 C T j = +2 C dh 2.76 kw T j = +2 C T j = +7 C dh 2.92 kw T j = +7 C T j = +12 C dh 2.97 kw T j = +12 C T j = operation limit temperature T j = bivalent temperature For air to water heat pumps: T j = -15 C (if TOL < -20 C) dh 2.40 kw dh 2.53 kw dh -- kw η s 135 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 C and outdoor temperature T j T j = operation limit temperature T j = bivalent temperature For air to water heat pumps: T j = -15 C (if TOL < -20 C) COd or ERd COd or ERd COd or ERd COd or ERd COd or ERd COd or ERd COd or ERd AGE 10 OF 24

12 Bivalent temperature Cycling interval capacity for heating Degradation coefficient T biv -7 C cych -- kw Cdh ower consumption in modes other than active mode Off mode OFF kw Thermostat-off mode TO 0 kw Standby mode SB kw Crankcase heater mode Other items CK 0 kw For air to water heat pumps: Operation limit temperature Cycling interval efficiency Heating water operating limit temperature TOL -10 C COcyc or ERcyc Supplementary heater Rated heat output Type of energy input or % WTOL -- C sup -- kw -- Capacity control fixed For air to water heat pumps: Rated air flow rate,outdoors m 3 /h Sound power level, indoors/outdoors Annual energy consumption L WA QHE For heat pump combination heater Declared load profile Daily electricity consumption db -- kwh or GJ Q elec - kwh For water/brine to water heat pumps: Rated brine or water flow rate, outdoor heat exchanger Water heating energy efficiency Daily fuel consumption m 3 /h η wh -- % Q fuel -- kwh AGE 11 OF 24

13 Annual electricity consumption AEC -- kwh Annual fuel consumption AFC -- GJ Contact details Guangzhou Jinlun Electric Equipment Co.,Ltd Jinlun Technology zone Qidong Rd Huadong Town Huadu District Guangzhou City..R.China Model Test method Outlet temperature type Test result Inlet dry bulb temperature for outdoor air C Inlet wet bulb temperature for outdoor air C Measurements and calculations MD30D Air enthalpy method Variable outlet Test condition A B C D E F Inlet temperatures for indoor C Outlet temperatures for indoor C Measured capacity W Measured power input W Static pressure difference ka Water volume flow rate m 3 /h Measured power input of compressor off state W Corrections of the power input of liquid pump if applicable hydrau W Efficiency of the pump Fraction power for calculation W Effective capacity W Effecitve power input W Calculated CO AGE 12 OF 24

14 Electric power consumption during thermostat-off mode, standby mode, crankcase heater mode and off mode Off mode kw Thermostat-off mode kw 0 Standby mode kw Crankcase heater mode kw 0 Calculations for seasonal space heating energy efficiency Test condition A B C D E F Outdoor heat exchanger Outdoor air C Indoor heat exchanger C Outlet water temperature C art Load Ratio % art Load kw Tested Capacity kw Tested CO Cc CR CO at A, B, C, D, E, F condition % % % % % % SCOon 4.03 SCOnet 4.01 SCO 4 η s % 135 Tested sound power level L WA db 54 AGE 13 OF 24

15 EN14511 Clause Requirement - Test Result - Remark Verdict 4 Requirements 4.2 Temperature operating range Starting test The unit shall be capable of operating within the limit of use indicated by the manufacturer. For every condition stated in Table 1, and for both cooling and heating mode where applicable, the unit shall start up and operate for at least 20 min, without being stopped by the safety devices. The temperatures are set at the beginning of the test and maintained constant during the test. Test voltage shall be as specified in Table 1. It is set at the beginning of the test and maintained constant during the test. The environmental conditions during the test shall be as specified in Tables 1 and 2 of EN :2004. The flow rates shall be the same as that used for rating capacity test, as specified in EN Deviation between individual values and set values shall be between: zero and minus twice the permissible deviation according to Table 2 of EN :2004, for the upper limit of use; zero and plus twice the permissible deviation according to Table 2 of EN :2004, for the lower limit of use. Uncertainty of measurement shall be as specified in Table 1 of EN :2004. EN14511 Clause Requirement - Test Result - Remark Verdict AGE 14 OF 24

16 EN14511 Clause Requirement - Test Result - Remark Verdict Test at maximum operating conditions (cooling mode) When operated at conditions stated in Table 2 during 1 h, then switch off for 3 min, and then switched on again for 1 h, the unit shall meet the following requirements: - the unit shall suffer no damage; the unit motor shall operate continuously for the first hour without tripping of the motor overload protective devices; after the shut-down period of 3 min, the unit shall restart automatically no more than 5 min after restarting of the compressor; the unit motor shall operate again continuously for the rest of the second hour without tripping of the motor overload protective devices. NOTE When possible, switching off the unit should be done through the control panel of the unit. This test can be combined with the corresponding starting test, except for control cabinet air conditioners where the inlet temperature at the indoor heat exchanger is lowered to 35 C after the starting time Freeze-up test Air-cooled unit After the unit has operated for 6 h at the conditions stated in Table 3, and after the last freeze up cycle has completed, the following requirements shall be fulfilled: no ice shall have accumulated on the evaporator; no ice shall drip from the unit; no water shall drip or be blown off the unit into the room. the saturated temperature corresponding to the pressure measured at the suction of the compressor shall not have decreased by more than 2 K. For all units, electrical power voltage and frequency shall be given by the manufacturer. 4.4 Shutting off the heat transfer medium flows To check the correct operating of the safety devices on the unit, the following faults shall be simulated consecutively. The unit shall have attained steady state in the standard rating conditions according to Tables 3 to 15 of EN :2004 before every fault is simulated. Each fault simulated shall be maintained for at least 1 h. 4.5 Complete power supply failure AGE 15 OF 24

17 Complete power supply failure lasting approximately 5 s shall be simulated. The unit shall have attained steady state conditions before the fault simulation, at the standard rating condition according to Table 3 to 15 of EN :2004. After restoration of power the unit shall restart automatically no more than 20 min after the compressor has been allowed to restart by the control devices of the unit. The unit is checked for any damage sustained during the test and if any safety devices have operated during the test. The test does not apply when the manufacturer states that the machine does not automatically restart after power supply failure. 4.6 Condensate draining and enclosure sweat test In heating mode, draining of condensate, including that formed on the enclosure, shall be made correctly when operating at the standard rating conditions given in Tables 3 to 15 of EN :2004. In cooling mode, draining of condensate, including that formed on the enclosure, shall be made correctly when operating at conditions given in Table 5. During the test of 4 h no condensed water shall drip, run or blow off the unit except through the drain. For indoor units, drain holes shall be provided with suitable pipe connection, the minimum diameter of which shall be 12 mm. 4.7 Defrosting (where applicable) The functioning of any defrosting system shall be specified under any one of the application rating conditions (see Table 3 to 15 in EN :2004), where frosting occurs. Successive frosting/defrosting cycles shall be repeated without running in progressively deteriorating average performances. There shall not be growth of ice in and around the drip tray. 4.8 Other requirements Components in air handling systems, such as fans, filters, heat exchangers, etc., shall be easily accessible and resistant for cleaning purposes recommended by the manufacturer. AGE 16 OF 24

18 EN14511 Clause Requirement - Test Result - Remark Verdict 5 Marking. Each unit shall have a durable, permanently fixed rating plate that is easily readable or accessible when the unit is in position for use, bearing at least the following information in addition to information required by safety standards. In the case of units consisting of several parts which can be made by different matching, only items a) and b) are to be indicated, where item b) applies to each part. Items c) and d) depend on the considered matching and shall be indicated in the manufacturer's data sheet. a) manufacturer or supplier; b) manufacturer's model designation and serial number; c) the CO and/or EER to three significant figures and the standard rating condition at which it is measured according to Tables 3 to 15 of EN :2004; d) heating/cooling capacity in kilowatts, with two digits after the decimal comma but not more than 3 significant figures at the test condition given in item c) of clause 5. e) for control cabinet air conditioners, the sensible cooling capacity in kilowatts, with one digit after the decimal comma but not more than 3 significant figures at the test condition given in item c) of clause 5. Further information may be provided; with regard to rating only the other rating conditions given in Tables 3 to 15 of EN :2004 are to be used. 6 Technical data sheet 6.2 erformance characteristics Rating characteristics The manufacturer shall provide in a table or as a graph the rating characteristics according to EN and EN Rating characteristics include: the cooling capacity, the effective power input, the EER and the SHR (where applicable); the heating capacity, the effective power input and the CO (where applicable); the heat recovery capacity and the type of liquid (where applicable). The manufacturer shall state that the characteristics apply to a new unit with clean heat exchangers Additional characteristics AGE 17 OF 24

19 EN14511 Clause Requirement - Test Result - Remark Verdict In addition, the manufacturer shall provide the following characteristics for the rated point(s): non ducted air-to-air units: flow rates or rotational speeds of fans; non ducted air-to-water units: air flow rate or rotational speed of fan; water flow rate and pressure difference; unit intended to discharge into double floor: nominal flow rate and external static pressure difference; other types of units: nominal flow rates and external static pressure differences for air and water Sound characteristics The manufacturer shall provide the sound power level and the corresponding test method according to ENV Electrical characteristics The manufacturer shall specify the electrical the characteristics in accordance with EN or EN as applicable and: maximum starting current of the unit, as defined in EN ; total power input and current at the rated point, excluding the starting period; reactive power or power factor at the rated point, for units with a total power input greater than 10 kw; power input of fan and pump if included in the units. 6.4 Operating range The manufacturer shall specify: limits of use (temperatures and flows); whether there are devices fitted which do not allow the unit to operate when these limits are exceeded. 7 Instructions 7.1 General If not already required by other standards, the manufacturer shall provide the information as described. 7.2 hysical description Refrigerant, air and/or liquid circuits See instructions AGE 18 OF 24

20 EN14511 Clause Requirement - Test Result - Remark Verdict The manufacturer shall:. specify the refrigerant, air and liquid circuits preferably providing circuit diagrams, showing every functional unit, control and safety device and specifying their type; if the unit uses water in the heat exchangers specify the water capacity contained in the unit, and specify either the constructional materials of the heat exchangers or the water quality; if used, specify the type of brine and the concentration into any other liquid; specify the type of oil to be used in the compressor Additional heating devices, when integral to the unit The manufacturer shall specify the type and location of additional heating devices and their control and safety devices Control and safety The manufacturer shall: state the functions achieved by the control and safety devices provided with the unit and specify when applicable their provision for adjustment and the method by which the safety devices are reset; provide specifications for any control or safety devices necessary to ensure correct operation of the unit but which are not provided with the unit; specify any limitation to the use of the rest of the installation. 7.3 Instructions for installation The manufacturer shall specify in particular: the required location conditions (whether units are to be installed outside or in a weather proof enclosure, or in a heated space); requirements of physical layout, access and clearance; requirements for the electrical, liquid, air and refrigerant connections, to be made on site; the location of warning and tripping devices; the installation precautions to be taken to ensure, in particular: correct circulation of the heat transfer media; water draining; cleanliness of heat exchange surfaces; to minimise noise, vibration or other adverse effects. Special indications for units using soil, sea water, ground water or surface water: specify any materials which are in contact with the water or with the brine. EN14511 Clause Requirement - Test Result - Remark Verdict AGE 19 OF 24

21 7.4 Instruction for maintenance The manufacturer shall state: content and frequency of routine maintenance operations to be performed by the user; content and frequency of maintenance and inspection operations which shall be performed by a specialist. AGE 20 OF 24

22 EN ISO 4871 Clause Requirement - Test Result - Remark Verdict 6 Verification of Noise emission values declarations The quantity to be verified is either the declared single-number noise emission value L d, or the sum of the measured noise emission value L, and the uncertainty K, depending on the form of the noise emission declaration. Verification shall be effected by means of noise measurements made according to the same noise test code, or, if there is no noise test code, according to a basic measurement standard with the same or better grade of accuracy, and under the same machinery or equipment operating conditions as those to which the declared noise equation values refer. AGE 21 OF 24

23 AENDIX icture 1 icture 2 AGE 22 OF 24

24 AENDIX icture 3 icture 4 AGE 23 OF 24

25 Notice 1. This test report shall be invalidation without the cachet of the testing laboratory. 2. This copied report shall be invalidation without sealed the cachet of the testing laboratory. 3. This report shall be invalidation without tester signature, reviewer signature and approver signature. 4. This altered report shall be invalidation. 5. Client shall put forward demurrer within 15days after received report. The testing laboratory shall refuse disposal if exceeded the time limit. 6. The test results presented in this report relate only to the object tested. AGE 24 OF 24

Page 2 of 42 Test report no. HS Rev.00

Page 2 of 42 Test report no. HS Rev.00 age 2 of 42 Test sample.....: Type of test object... : Trademark... : Heat ump Heat ump Hiseer Model and/or type reference... : AS14S-DNHE Rating(s)... : 380-415 V 3N~; 50Hz; other rating refer to page

More information

The test items passed the test specification(s).

The test items passed the test specification(s). Report NO.: NTRE20170442 Test Report No.: NTRE20170442 age 1 of 17 Applicant Name: Test item: Gree Electric Appliances Inc. of Zhuhai West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Split Air

More information

AS10S-DPNHE. Rating(s)... : V 3N~; 50Hz; other rating refer to page 6. Guangzhou Hiseer Air conditioning Co,. LTD

AS10S-DPNHE. Rating(s)... : V 3N~; 50Hz; other rating refer to page 6. Guangzhou Hiseer Air conditioning Co,. LTD age 2 of 42 Test sample.....: Type of test object... : Trademark... : Model and/or type reference... : Heat ump Heat ump Hiseer AS10S-DNHE Rating(s)... : 380-415 V 3N~; 50Hz; other rating refer to page

More information

Model and/or type reference... : COPMAX GS 15 JORDVARMEPUMPE Rating(s)... : V 3N~; 50Hz; other rating refer to page 6

Model and/or type reference... : COPMAX GS 15 JORDVARMEPUMPE Rating(s)... : V 3N~; 50Hz; other rating refer to page 6 age 2 of 42 Test sample.....: Type of test object... : Trademark... : Heat ump Heat ump Hiseer Model and/or type reference... : COMAX GS 15 JORDVARMEUME Rating(s)... : 380-415 V 3N~; 50Hz; other rating

More information

Report Reference No...:

Report Reference No...: TEST REORT COMMISSION REGULATION (EU) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European arliament and of the Council with regard to ecodesign requirements for air conditioners

More information

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013 Delegated Regulation (EU) 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature

More information

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign

More information

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS 6.9.2013 Official Journal of the European Union L 239/1 II (Non-legislative acts) REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of

More information

Test Report No.: Page 2 of 14

Test Report No.: Page 2 of 14 Test Report No.: 15039191 001 age 2 of 14 Test item particulars: Class of protection... : Degree of protection... : Class of temperature... : Testing: Class I IX0 Date of receipt of test item... : 2010.06.28

More information

ANNEXES. to the. COMMISSION REGULATION (EU) No /..

ANNEXES. to the. COMMISSION REGULATION (EU) No /.. EUROPEAN COMMISSION Brussels, 30.11.2016 C(2016) 7769 final ANNEXES 1 to 5 ANNEXES to the COMMISSION REGULATION (EU) No /.. implementing Directive 2009/125/EC of the European Parliament and of the Council

More information

Draft COMMUNICATION FROM THE COMMISSION

Draft COMMUNICATION FROM THE COMMISSION EUROPEAN COMMISSION Brussels, XXX [ ](2012) XXX draft Draft COMMUNICATION FROM THE COMMISSION in the framework of the implementation of Commission Regulation (EU) No / implementing Directive 2009/125/EC

More information

EHPA Testing Regulation

EHPA Testing Regulation EHPA Testing Regulation Testing of Heat Pumps for Domestic Hot Water Production Terms, Test Conditions and Test Method based on EN 16147 Additional requirements for granting the international quality label

More information

ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)

ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW) ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW) Table of Contents Annex I Definitions applicable for the purposes of Annex II to IV...

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 20.12.2016 L 346/1 II (Non-legislative acts) REGULATIONS COMMISSION REGULATION (EU) 2016/2281 of 30 November 2016 implementing Directive 2009/125/EC of the European Parliament and of the Council establishing

More information

WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)

WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW) WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW) Table of Contents Explanatory Notes... 2 Form of the implementing measures... 2 Scope... 3 Market

More information

Teknik Data NIBE F2120 8, 12, 16, 20

Teknik Data NIBE F2120 8, 12, 16, 20 Teknik Data NIBE F21, 12, 1, Havadan Suya Isı Pompası LEK F21 F21 Teknik Data Ebatlar F21 Ø2 30 0 0 0 1 10 F2112, 1, Ø2 10 1 0 0 0 1 12 1 LEK Ses basıncı seviyeleri F21 is usually placed next to a house

More information

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS Date : 09/09/2013 revised 26/09/2013 Auteur : MMT Destinataires pour action : UNICLIMA Document de travail DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS The document exclusively includes technical

More information

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

A Notification under Article 12 of Regulation (EU) No 1025/2012 1 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Sustainable Growth and EU 2020 Standards for Boosting Competitiveness Brussels, 02/07/2014 A Notification under Article 12 of Regulation

More information

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162.

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162. 2 Table of Contents 1. Purpose of the guidelines and disclaimer... 4 1.1. The Regulations... 4 2. Scope... 4 2.1. Space Heaters and Combination Heaters... 5 2.2. Water Heaters... 5 3. Product environmental

More information

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT SAUDI ARABIAN STANDARD SASO 2663/2017 والجودة الھيئة السعودية للمواصفات والمقاييس Saudi Standards, Metrology and Quality Org (SASO) SASO 2663:2017 (Draft) AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING

More information

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX COMMISSION DELEGATED REGULATION (EU) No /.. of XXX supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

The products covered by the Regulation can be classified as follows:

The products covered by the Regulation can be classified as follows: Table of Contents 1. Purpose of the guidelines and disclaimer... 3 1.1. The Regulation... 3 2. Scope... 3 3. Product environmental impacts... 4 4. State of play of legislation... 4 4.1. History of the

More information

EHPA Testing Regulation

EHPA Testing Regulation EHPA Testing Regulation Testing of Water/Water and Brine/Water Heat Pumps Terms, Test Conditions and Test Method based on EN 14511-1 to 14511-4 and EN 12102 Additional requirements for granting the international

More information

COMMISSION REGULATION (EU)

COMMISSION REGULATION (EU) 10.3.2012 Official Journal of the European Union L 72/7 COMMISSION REGULATION (EU) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard

More information

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 12TH0525-EN50438_SUM_0 Date of issue......:

More information

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136. 2 This document reflects the opinion of the European Commission and does not provide a legally binding interpretation of the regulations. Only the European Court of Law can provide a legally binding interpretation

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL DTW_1SP005E_01 DESIGN & TECHNICAL MANUAL Comfort series ( Single phase type ) INNOVATIVE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS SINGLE PHASE TYPE : WO A060LFCA, WO

More information

Product fiche concerning the COMMISSION DELEGATED REGULATIONS

Product fiche concerning the COMMISSION DELEGATED REGULATIONS Product fiche concerning the COMMISSION DELEGATED REGULATIONS (EU) No 811/2013 of 18 February 2013 (EU) No 813/2013 of 2 August 2013 Oil Boilers Pro Range: Vortex Outdoor Module Condensing boiler Yes Yes

More information

COMMISSION REGULATION (EU) No /.. of

COMMISSION REGULATION (EU) No /.. of EUROPEAN COMMISSION Brussels, 30.11.2016 C(2016) 7769 final COMMISSION REGULATION (EU) No /.. of 30.11.2016 implementing Directive 2009/125/EC of the European Parliament and of the Council establishing

More information

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX D028689/03 [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to

More information

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION DELEGATED REGULATION (EU) No /.. of XXX supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to

More information

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign

More information

(Text with EEA relevance)

(Text with EEA relevance) L 193/76 21.7.2015 COMMISSION REGULATION (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance Test Report issued under the responsibility of: SGS- CSTC TEST REORT Safety of household and similar electrical appliances art 2: articular requirements for massage appliance Report Reference No....: GZES100800181503

More information

Product Information as required by EU regulations No 811/2013 and No 813/2013

Product Information as required by EU regulations No 811/2013 and No 813/2013 Product Information as required by EU regulations 811/2013 and 813/2013 Rev : 1.0 Product Fiche (according to EU regulation 811/2013) (a) Supplier s name or trademark E.C.A. (b) Supplier s model identifier

More information

B COMMISSION REGULATION (EU)

B COMMISSION REGULATION (EU) 02014R0066 EN 09.01.2017 001.001 1 This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions

More information

Consumer Products Services Germany GmbH Türkheim Germany

Consumer Products Services Germany GmbH Türkheim Germany TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 11TH0290-EN50438_SUM_2 Date of issue......:

More information

Refrigerating Appliance ErP Test Report

Refrigerating Appliance ErP Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

COMMISSION DELEGATED REGULATION (EU) No /.. of

COMMISSION DELEGATED REGULATION (EU) No /.. of EUROPEAN COMMISSION Brussels, 18.2.2013 C(2013) 818 final Part 1/6 COMMISSION DELEGATED REGULATION (EU) No /.. of 18.2.2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council

More information

White paper: New Ecodesign rules and energy labelling for space and water heaters

White paper: New Ecodesign rules and energy labelling for space and water heaters White paper: New Ecodesign rules and energy labelling for space and water heaters White paper: New Ecodesign rules and energy labelling for space and water heaters The Ecodesign Regulation is one of the

More information

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX [ ](2014) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign

More information

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1) A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1) What do the new regulations require? The Energy Related Products (ErP) Regulations require that: From the 1 st January

More information

Technical data LA 60TUR+

Technical data LA 60TUR+ Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors

More information

ANNEXES. to the COMMISSION DELEGATED REGULATION

ANNEXES. to the COMMISSION DELEGATED REGULATION EUROPEAN COMMISSION Brussels, XXX [ ](2018) XXX draft ANNEXES 1 to 9 ANNEXES to the COMMISSION DELEGATED REGULATION supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council

More information

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods (1) Under Directive 2009/125/EC ecodesign requirements should be set by the Commission for energy-related

More information

Solar thermal solutions within the Energy Labelling Context

Solar thermal solutions within the Energy Labelling Context Solar thermal solutions within the Energy Labelling Context General features Place, Date General context linked to solar thermal solutions The Energy Labelling regulations refer to many solar items : Solar

More information

Official Journal of the European Union

Official Journal of the European Union 8.7.2015 L 177/19 COMMISSION REGULATION (EU) 2015/1095 of 5 May 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for professional

More information

ANNEXES. to the COMMISSION DELEGATED REGULATION

ANNEXES. to the COMMISSION DELEGATED REGULATION EUROPEAN COMMISSION Brussels, XXX [ ](2018) XXX draft ANNEXES 1 to 10 ANNEXES to the COMMISSION DELEGATED REGULATION supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council

More information

Product fiche concerning the COMMISSION DELEGATED REGULATIONS

Product fiche concerning the COMMISSION DELEGATED REGULATIONS VTXOM15/21 VTXOM15/26 VTXOM26/36 VTXOM36/46 VTXOM46/58 VTXOM58/70 Product fiche concerning the COMMISSION DELEGATED REGULATIONS (EU) No 811/2013 of 18 February 2013 (EU) No 813/2013 of 2 August 2013 Oil

More information

103776HV1241 NOVELAN LAV 8-HV kw kw db 50 db

103776HV1241 NOVELAN LAV 8-HV kw kw db 50 db NOVELAN 44 50 103776HV1241 5 7 6 7 6 4 NOVELAN 103776HV1241 package (heat pumps and combination heater with heat pump) Seasonal space heating energy efficiency of heat pump (ηs) of the heat pump (Prated

More information

Working Document on a possible COMMISSION DELEGATED REGULATION

Working Document on a possible COMMISSION DELEGATED REGULATION Working Document on a possible COMMISSION DELEGATED REGULATION Implementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of vacuum cleaners EN EN Working

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6 EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion

More information

Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners

Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners Incorporated and adapted by Ministerial Council Decision 2011/03/MC-EnC

More information

AIR CONDITIONER PERFORMANCE RATING

AIR CONDITIONER PERFORMANCE RATING HPRATE V5.1 AIR CONDITIONER PERFORMANCE RATING by G.L. Morrison MechLab The University of New South Wales.EDU.AU September 2012 Version 5.1 HPRATE 5 Air Conditioner Performance Rating 1 HPRATE AIR CONDITIONER

More information

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)... TEST REORT AS 4777.2:2005 and AS 4777.3:2005 with additional deviations for Israel Grid connection of energy systems via inverters Grid protection requirements Report reference No...: 10TH0052_AS4777_+_ISR_3

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION SCOPE OF ACCREDITATION Vipac Engineers and Scientists Ltd T/A Gas Technology Services Victorian Laboratory Address Details: Victorian Technology Centre 275-283 Normanby Road PORT MELBOURNE, VIC AUSTRALIA

More information

Installer manual ELK 213 Immersion heater

Installer manual ELK 213 Immersion heater Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...: Test Report issued under the responsibility of: TEST REORT IEC 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX EUROPEAN COMMISSION Brussels, XXX [ ](2012) XXX draft COMMISSION DELEGATED REGULATION (EU) No /.. of XXX supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to

More information

COMMISSION REGULATION (EU)

COMMISSION REGULATION (EU) 31.1.2014 Official Journal of the European Union L 29/33 COMMISSION REGULATION (EU) No 66/2014 of 14 January 2014 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard

More information

Council of the European Union Brussels, 14 July 2014 (OR. en)

Council of the European Union Brussels, 14 July 2014 (OR. en) Council of the European Union Brussels, 14 July 2014 (OR. en) 11898/14 ENER 354 ENV 676 COVER NOTE From: European Commission date of receipt: 11 July 2014 To: No. Cion doc.: D033491/02 Subject: General

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 9.5.2012 Official Journal of the European Union L 123/1 II (Non-legislative acts) REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 392/2012 of 1 March 2012 supplementing Directive 2010/30/EU of the

More information

HEAT PUMPS MAGIS PRO ErP

HEAT PUMPS MAGIS PRO ErP HEAT PUMPS MAGIS PRO ErP Split single-phase inverter reversible air-water heat pumps with outdoor condensing unit and hydronic module INDEX MAIN INDEX 1 MAGIS PRO 5-8 - 10 ErP FEATURES (MONO-PHASE)...5

More information

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES Poster P.6.13-1 - EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES Markus Lindahl, MSc, SP Technical Research Institute of Technology, Energy Technology, Box 857, 501 15 Borås, Sweden; Caroline,

More information

Page 2 of 14 Report Ref. No

Page 2 of 14 Report Ref. No age 2 of 14 Summary of testing: Tests performed (name of test and test clause): Clause 6.1, Initial measurements: - MST 01: Visual inspection - 10.2: Maximum power determination - MST 16: Dielectric withstand

More information

DRAFT KENYA STANDARD DKS 2463: 2018 ICS Non-ducted air conditioners Testing and rating performance

DRAFT KENYA STANDARD DKS 2463: 2018 ICS Non-ducted air conditioners Testing and rating performance DRAFT KENYA STANDARD DKS 2463: 2018 ICS 23.120 Non-ducted air conditioners Testing and rating performance KEBS 2018 Second Edition 2018 TECHNICAL COMMITTEE REPRESENTATION The following organizations were

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

ANNEXES. to the. Commission Delegated Regulation

ANNEXES. to the. Commission Delegated Regulation EUROPEAN COMMISSION Brussels, XXX [ ](2018) XXX draft ANNEXES 1 to 9 ANNEXES to the Commission Delegated Regulation supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 30.11.2010 Official Journal of the European Union L 314/1 II (Non-legislative acts) REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU

More information

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013 Product Testing Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013 On July the 13 th, 2013, the EU 665/2013 & EU 666/2013 directives were officially published on the Official

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

EU GPP Criteria for Water-based Heaters

EU GPP Criteria for Water-based Heaters EU GPP Criteria for Water-based Heaters EU GPP criteria aim at facilitating public authorities the purchase of products, services and works with reduced environmental impacts. The use of the criteria is

More information

Working Document on a Draft. COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

Working Document on a Draft. COMMISSION DELEGATED REGULATION (EU) No /.. of XXX Working Document on a Draft COMMISSION DELEGATED REGULATION (EU) No /.. of XXX supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of water

More information

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY ErP READY The Eco-Design Directive ErP for refrigerator systems and heat pumps. The EU-Regulation 2281/2016/EU defines the new requirements for refrigerator systems and heat pumps and focuses on the new

More information

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG. AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG. Page1 CONTENT: 1. Product Description 2. Product Specifications 3. Operating Procedure 4. Observation Table 5. Calculations 6. Result Page2

More information

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance DRAFT INTERNATIONAL STANDARD ISO/DIS 15042 ISO/TC 86/SC 6 Voting begins on: 2005-07-11 Secretariat: ANSI Voting terminates on: 2005-12-12 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

(Non-legislative acts) REGULATIONS

(Non-legislative acts) REGULATIONS 12.10.2012 Official Journal of the European Union L 278/1 II (Non-legislative acts) REGULATIONS COMMISSION REGULATION (EU) No 932/2012 of 3 October 2012 implementing Directive 2009/125/EC of the European

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Working Document on a Draft

Working Document on a Draft Working Document on a Draft Commission communication in the framework of the implementation of Commission Regulation (EU) No / implementing Directive 2009/125/EC of the European Parliament and of the Council

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information