Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and
|
|
- Shannon Bradford
- 5 years ago
- Views:
Transcription
1 Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns. MODELS: SCD: Supply ceiling diffuser. RCD: Return ceiling diffuser.
2 Linear Slot Diffusers : Frame and Curved deflection blades are made of extruded aluminum alloy 6063 to T6 heat treatment. Available with GI sheet to control air flow patterns. MODELS: SLD: Supply Linear diffuser. RLD: Return Linear diffuser
3 Linear Bar Grills : SAMA Linear bar grille " single deflection " is wall mounted grille, used as supply or return grille in cooling, heating or ventilation applications. The single deflections linear grille is composed of a set of fixed horizontal straight bars attached to frame, both manufactured from extruded aluminum sections. MODELS: SLBG: Supply linear bar grille. RLBG: Return linear bar grille. SLRG: Supply linear Register. RLRG: Return linear Register
4 Supply Air Grille & Registers : The single deflection air grill is composed of a set of deflecting blades mounted on a rectangular shaped frames. The double deflection air grille is composed two sets of deflecting blades mounted in two adjacent planes. The two sets of deflecting blades are mounted in such a way that one set is vertically mounted and the other set is horizontally mounted. The single and double deflection air grille are used for cooling, heating or air ventilation. MODELS: SAG D/D ( With Damper ) SAG S/D ( With Damper ) SAG D/D ( Without Damper ) SAG S/D (Without Damper )
5 Fixed Blade: SAMA fixed blade is composed of a set of horizontally mounted fixed blades that are made of extruded aluminum. MODELS: FBH FBV FBRV
6 Round Diffuser : Fully adjustable air discharge pattern horizontal vertical, for spot cooling, heating and ventilating application. Removable inner core assembly for easy installation. Aluminum construction. Standard color RAL9016. MODELS : SRCD: Supply Round Ceiling diffuser. RRCD: Return Round Ceiling diffuser.
7 Jet Diffuser : Aluminum construction with extruded aluminum frame. Adjustable core provide air discharge up to 30 degree from the mid position in any plane. Single element provide direct connection to round duct system. MODEL : JD: Jet diffuser.
8 Disc Valve : Air flow rate can be controlled by rotating the central disc. Central disc is fixed by locking nut. Face galvanized steel. Spindle and locking nut galvanized steel. MODELS : DV: Disc Valve.
9 Door Grille : SAMA Door grille composed of a set of horizontally V-shape blades mounted with fixed spacing to a frame called the fixed frame. MODELS : DG: Door Grille.
10 Egg Crate : SAMA Egg Crate frame made of extruded aluminum and core of square aluminum sheet standard color white powder coating to ( RAL 9016 or 9010 ). MODELS: EC: Egg Crate.
11 Fresh Air Intake & Exhaust Louvers: Air louvers is composed of a set of horizontal mounted fixed blades and inclined down 45 Spaced 35 mm or 50mm on center, blades and frame are manufactured from extruded aluminum Alloy ( 6063-t6 ) designed for both intake and exhaust opening.
12 Sand Trap Louver: SAMA sand trap louver manufactured for fresh air intake in HVAC systems, which are designed To separated large size sand particles at low air velocities thus avoiding excessive dust Loading performance for air filtration and moderate pressure drops at low air velocities.
13 Access Door Grilles : The frames are made of extorted aluminum alloy, access door grille core can be fabricate from fixed blade, egg crate and perforated sheets. standard color is white powder coating ( RAL 9016).
14 Access Door Duct SAMA manufactures Access Doors Duct that are designed for use in central air conditioning ductwork systems to provide access for resetting of Fire Dampers, Heaters, Filters or other maintenance works. The strong and robust construction of the access door guarantees low leakage of air even with high duct pressures. Double walled door panel with mineral wool insulation will act as better resistance for transfer of heat..
15 Volume Control Damper : Volume control damper is made of multi blades, parallel, and frame is flange type of Galvanized steel construction, hand locking quadrant is provided manual operation, Extended shaft and motor base is provided for motorized operation. the blades are mounted on nylon bushing and operated by external linkage.
16 Fire Dampers : Fire damper are made of 20 gauge galvanized steel blades are curtain type of gravity shutter without negatron closure spring for static operation or with stainless steel negatron spring for dynamic operation
17 Fire & Smoke Dampers : Combination fire & smoke damper meet the requirement of safety in HVAC system. FSD consist of a fire damper and smoke damper together as a single damper. FSD is used in HVAC system where a wall, floor or ceiling is celling is required to have both a fire and smoke damper. FSD close up on the detection of heat ( via duct temperature ) or smoke via ( via smoke detector ). FSD is available with electric heat devices instead of fusible links in regular fire damper.
18 Back Draft Damper : From light operations to heavy-duty industrial applications, SAMA provides the perfect back draft damper. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. The industrial grade back draft dampers offer rugged construction & heavy gage materials to with stand the high velocities & back pressure associated with heavy duty installations. SAMA has developed three types of Back Draft Dampers as following : 1. Light Back Draft Damper. 2. Back Draft Damper. 3. Pressure Relief Damper.
19 Variable Air Volume (VAV) * Variable Air Volume (VAV) is a type of heating, ventilating, and/or air-conditioning (HVAC) system. Unlike constant air volume systems, which supply a constant airflow at a variable temperature, VAV systems vary the airflow at a constant temperature. * Variable Air Volume Systems are the best way to zone especially in large buildings. A VAV system with the proper controls and set-up will help the building owner realize large savings in energy usage.
20 Sound Attenuators : Sound attenuators are constructed to the relevant of HVAC ducting work. Casing is 20 gauge galvanized steel. Baffle are made of 20 gauge galvanized steel perforated galvanized steel filled with sound obsorbing material. Flange from steel angle.
SECTION AIR DUCT ACCESSORIES
SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control
More informationAIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY
AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY WWW.ANTALYA-AIRTECH.COM ANTALYA FACTORY 2 INTRODUCTION INTRODUCTION We are honored to introduce our firm ANTALYA AIR TECHNOLOGY FACTORY
More informationSECTION AIR OUTLETS AND INLETS
SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.
More informationFIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.
FIRE & SMOKE DAMPERS Meeting tomorrow's requirements for fire and smoke protection today. LATEST TECHNOLOGY For more than 40 years Ruskin has led the HVAC industry in the manufacture of dampers and louvers.
More informationD. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.
SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:
More informationSECTION (15820) - AIR DUCT ACCESSORIES
PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors
More informationAIR DUCT ACCESSORIES
SECTION 233300 - PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationlindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles
lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to
More informationLife Safety Dampers Selection and Application Manual
Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers August 2016 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER
More informationAdvanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions
ISSUE A, MAY 2008 Hard Wired Damper Control Panels Systems 10, 11, & 12 Hard-Wired Systems Bespoke Systems Available Value Engineered Solutions Overview The Hard-Wired Control Panels On a number of projects
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous
More informationA. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.
15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationAIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems
233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section
More informationALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector
ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential
More informationSECTION (15833) - HVAC POWER VENTILATORS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted
More informationINSTALLATION DO S AND DON TS
4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationSECTION DUCTWORK
SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).
More informationDisplacement Ventilation
Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution
More informationCONTENTS. B. System Design and Performance Requirements
15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationB. System Design and Performance Requirements
15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationAIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION
Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013
SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationCenteral Station Air Handling Unit
Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof
More informationAIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.
SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationINSTRUMENTATION AND CONTROL DEVICES FOR HVAC
PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationset 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)
1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto
More informationLinear Floor Heaters
Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED
More informationCeiling diffusers. Type DLQL
X X testregistrierung Type Horizontal one-way air discharge Horizontal two-way air discharge Horizontal four-way air discharge Horizontal duct connection For horizontal one-way to four-way air discharge,
More informationSPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS
SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification
More informationTunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety
Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2017 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,
More informationGUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)
GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) February, 2017 Contents Clauses Page 1. Basic Concepts 1 2. Design Considerations 1 3. Car Parks Ventilation 2 4. Kitchen
More informationBypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS
BYPASS TERMINAL UNITS DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial & Institutional). 2 BYPASS TERMINAL
More informationPDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 PDH & Professional Training PDH Storm, by Engineers Edge, LLC CONTENTS 1. INTRODUCTION 1.1 GENERAL CRITERIA 1.2 DESIGN PROCEDURE
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationEXHAUST FAN SCHEDULE
DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationVentZone Systems VentZone Zoned IAQ with Heat Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential
More informationA. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.
Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section
More informationEngineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.
VAV Diffusers lease refer to the rice Engineer s HVAC Handbook for more information on VAV Diffusers. Diffuser Types Ceiling Diffusers Conventional air distribution systems typically group several rooms
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationVentZone Systems VentZone Zoned IAQ with Energy Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationConvectors Steam / Hot Water November, 2009
Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.
More informationAUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1
PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening
More informationENVIRO UNIT ENGINEERING MANUAL KES SERIES
ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units
More informationTunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety
Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2011 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationFire dampers. For diverse applications
. X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular
More information1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT
Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story
More informationDACC Health Sciences Building Air Handler Assessment/Study
DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.
More informationLife Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering
Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationTechnical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers
elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationLenntech. Tel Fax
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 MC Fluid Cooler Unmatched reliability Heavy-duty construction, high performance design and our five-year mechanical
More informationType FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU
Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small rectangular fire damper for the isolation of duct penetrations
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationAIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters
237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices
More informationBulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications
Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment
More informationAIR TERMINALS & DUCT HEATERS.
AIR TERMINALS & DUCT HEATERS. TABLE OF CONTENTS. 4 2 CAV AIR TERMINAL UNITS 3 BYPASS AIR TERMINAL UNITS 52 DIGITAL THERMOSTATS FOR AIR TERMINAL UNITS 2 3 VAV AIR TERMINAL UNITS 4 5 SINGLE DUCT PRESSURE
More informationType FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU
Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments, for a variety of installation situations, available in many different sizes
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCESA / NASA UFGS-23 00 00 (October 2006) ---------------------------- Preparing Activity: USACE Superseding UFGS-23 00 00 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationChore-Time Fan Guide For Tunnel and Other Applications
Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time s Fiberglass and Galvanized Fans Provide Efficiency and Performance Diameters available through 54 Inches (137.2 cm) Chore-Time s TURBO
More informationThe Corona air inlet TECHNICAL SPECIFICATIONS
710 The Corona air inlet Proper distribution of air in a house for animals can be a challenging task. The ventilation system should be able to maintain a perfect climate throughout the production cycle.
More informationINDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.
BLOWERS With over 70 years of experience and expertise our fans will ensure your projects are a success. ABOUT OUR PARTNERSHIP has been representing Chicago Blower Corporation (USA) since 2004, offering
More informationThe PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty
MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct
More informationBES-TECH TECHNOLOGY & SYSTEM INTEGRATION
BES-TECH TECHNOLOGY & SYSTEM INTEGRATION BES-TECH TECHNOLOGY & SYSTEM INTEGRATION DIGI-ACC Digi-ACC is a control kit for air cooled chiller systems, optimizing both chiller and pumps thereby reducing consumption
More information+91-9582815184 Enviro Tech Industrial Products www.envirotechindustrialproducts.net We are recognized as a leading Manufacturer, Trader, Exporter and Supplier of high quality Clean Room Equipment, Air
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Facilitator Healthcare Systemair - Ventilation World Wide Systemair is a leading ventilation
More informationType FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU
Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments,
More informationCONDOR. Supply air ceiling QUICK FACTS
Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O
More informationSECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.
SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been
More informationand SHUTTERS Made to Work. Built to Last.
FANS and SHUTTERS Made to Work. Built to Last. VANGUARD PLUS Fan with HYFLO Shutter Chore-Time s VANGUARD PLUS Cone Fan provides a great combination of performance, features and value. Add Chore-Time s
More informationA. This Section includes air-handling units with coils for indoor installations.
SECTION 237313 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes air-handling units with coils for indoor installations. 1.2 SUBMITTALS A. Product Data: For each type of indoor air-handling unit
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance
More informationSH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will
More informationATC Heating Devices. P. 1 ATC Heating Devices
ATC Heating Devices P. 1 ATC Heating Devices ATC Heating Devices Suspended water heater FWW The hot water heater is attached to a wall using brackets. The direction of air flow (upwards or downwards) is
More informationModular Heating & Ventilating Unit Model IGX-HV
Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit
More informationAgitation and Mixing
Agitation and Mixing Agitation: Agitation refers to the induced motion of a material in a specified way, usually in a circulatory pattern inside some sort of container. Purpose is to make homogeneous phase.
More informationGravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form
Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form PART 1 GRAVITY CHUTES CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LIMITED ACCESS OFFSETS DIMENSIONS VENTING CONSTRUCTION
More information