1 MEAT AREA DAIRY AREA
2 PLUMBING SCOPE OF WORK - WATER KEC TO PROVIDE: - ALL FAUCETS, AS REFLECTED ON EQUIPMENT SCHEDULE, - WATER CONNECTION FROM ICE MACHINE FILTER TO ICE MACHINE. PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL FIXTURES PROVIDED BY KEC, - FINAL CONNECTIONS FOR DISHWASHER, " SHUT OFF VALVE FROM STUB OUT TO ALL WATER FILTERS REFLECTED ON THIS PLAN, - NECESSARY BACK FLOW EQUIPMENT AT SODA EQUIPMENT AS PER CODE, - NECESSARY BACK FLOW EQUIPMENT FOR ICE MACHINE IF REQUIRED BY CODE. VENDOR TRADES: - FINAL CONNECTION FROM FILTER TO PROVIDED EQUIPMENT. PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - INSTALLATION OF PVC DRAINS FOR ICE MACHINE AND ICE BIN WITH NECESSARY AIR VENT AS PER CODE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY "P" TRAPS AS PER CODE, - PIPE CONDENSATE DRAIN FOR WALK IN FREEZER WITH 3/4" COPPER TUBING, WITH NECESSARY "P" TRAPS AS PER CODE, PROVIDE INSULATION AND HEAT TAPE IN ALL FREEZER AREAS. PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL NECESSARY DRAINAGE PIPING WITH PVC OR COPPER (AS REQUIRED) PIPE, AS REFLECTED ON THIS ROUGH IN PLAN FOR ALL SINKS AND EQUIPMENT, - INDIRECT DRAINS REQUIRE 1 1 2" AIR GAP ABOVE FLOOR SINK, - ANCHOR ALL INDIRECT PIPING WITH UNISTRUT AND STRAPS FOR CLEAN FINISH
3 PLUMBING CONTRACTOR ANSUL VALVE TO BE INSTALLED ON GAS LINE, ABOVE GRID PLUMBING CONTRACTOR RUN MAIN GAS LINE ABOVE WALL, PROVIDE 1" DROPS TO EACH STUB OUT LOCATION PLUMBING SCOPE OF WORK - GAS NOTES KEC TO PROVIDE: - QUICK DISCONNECT GAS HOSE KITS, 3 4" X 48" FOR EACH PIECE OF GAS EQUIPMENT AS NOTED ON EQUIPMENT SCHEDULE, - SOLENOID VALVE FOR MAIN GAS LINE SHUT OFF (PART OF THE ANSUL SYSTEM). PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL QUICK DISCONNECT GAS HOSES & SAFETY CABLES AS SHOW IN THE DETAIL ABOVE, - INSTALLATION OF SOLENOID VALVE FOR MAIN GAS LINE IN LOCATION DETAILED BY PLUMBING ENGINEER ON GAS LINE SCHEMATIC. - APPROPRIATE GAS PSI/W.C. TO ALL NECESSARY EQUIPMENT, PER SPEC SHEETS PROVIDED ELECTRICAL CONTRACTOR TO PROVIDE: - WIRING FROM SOLENOID VALVE TO ELECTRICAL CONTROLS OF HOOD SYSTEM.
4 1 2 CORD FROM CEILING FOR UTILITY OUTLET AT PREP TABLE CORD FROM CEILING FOR UTILITY OUTLET AT PREP TABLE 3 ELECTRICAL SCOPE OF WORK ELECTRICAL CONTRACTOR NOTES: 1) PROVIDE DIRECT SHUNT TRIP BREAKER FOR WALK IN FREEZER DOOR HEAT STRIP (BY KEC/WALK IN MANUFACTURER) AND DRAIN LINE HEATER (BY KEC) - WIRE TIME CLOCK IF SHIPPED LOOSE, 2) PROVIDE DISCONNECT SWITCH FOR EACH WALK IN CONDENSER WITHIN 6 FEET PER CODE, 3) WIRE EXHAUST FANS, MAKE UP AIR UNITS AND ALL DESIGNATED OUTLETS UNDER HOOD SYSTEMS INTO ELECTRICAL CONTROL PANEL (KEC PROVIDED). GENERAL NOTES: - PROVIDE GFI OUTLETS IN ALL AREAS OF THE KITCHEN, - DIRECT CONNECTIONS REQUIRED ARE TO BE WATERTIGHT CONDUIT
5 WALK IN COOLER/FREEZER REMOTE CONDENSER LINES, CONFIRM RUN IN FIELD CONDENSERS FOR WALK IN COOLER/FREEZER LOCATED IN BACK DOCK AREA ON FREE STANDING RACK - SEE DETAIL ANSUL PULL STATION LOCATION MECHANICAL ENGINEER NO AC REGISTERS WITHIN THIS PERIMETER MECHANICAL ENGINEER NO AC REGISTERS WITHIN THIS PERIMETER MAIN HOOD ELECTRICAL CONTROL LOCATION ANSUL PULL STATION LOCATION MECHANICAL SCOPE OF WORK KEC TO PROVIDE: - RECEIVING OF EQUIPMENT DELIVERY ONSITE, - HOOD BOXES, - 20 GA. S/S WALL FLASHING UP TO 120" HIGH (CONFIRM WITH GC CODE REQUIREMENT ON HEIGHT) FROM 4"ABOVE FLOOR, END OF HOOD TO END OF HOOD AND ANY SIDE WALL(S) AROUND PERIMETER OF HOOD, - EXHAUST FAN(S) & ROOF CURB(S), - EVAP COOLER/MAKE UP AIR UNIT & ROOF CURB(S), - ELECTRICAL CONTROL PANEL W/ RELAYS & CONTACTORS, - ANSUL SYSTEM PIPING, TANKS, PERMIT, INSTALLATION & FINAL TEST, - HANGING OF HOOD BOXES & INSTALLATION OF S/S WALL FLASHING, - PERFORMANCE CHECK OF SYSTEM AFTER HVAC START UP, - LOCATIONS FOR ROOF PENETRATIONS FOR REMOTE CONDENSERS WITH PVC CHASE, - PRESSURE TREATED 4"X4" WOOD FOR SETTING OF REMOTE CONDENSERS WHEN NECESSARY. GC/MECHANICAL CONTRACTOR TO PROVIDE: - RECEIVING OF ROOFTOP EQUIPMENT ONSITE, ONSITE STORAGE IF NECESSARY, - CRANE TO ROOFTOP, - CUTTING OF ROOF DECK & PLACEMENT OF CURBS, PATCHING OF ROOF, - GREASE DUCT/FIREWRAP & INSTALLATION, - MUA/AC DUCT & INSTALLATION, - MOUNTING OF ELECTRICAL CONTROLS (IF NECESSARY), - FINAL ELECTRICAL & PLUMBING CONNECTIONS, - START UP AND BALANCE OF HOOD WITH AC, - CUTTING AND SEAL ROOF PENETRATIONS FOR REMOTE CONDENSER LINE CHASE - PROVIDE GALVANIZED "GOOSE NECK" IF PREFERRED OVER KEC PROVIDED PVC. - CONDENSER CURBS SHOULD THEY BE REQUIRED OVER 4"X4" WOOD BY KEC. MECHANICAL NOTES: 1) EXHAUST DUCT RISER CONNECTION POINT 2) MAKE UP AIR/EVAP COOLER RISER CONNECTION POINT 3) AC DUCT RISER CONNECTION POINT 4) WATER HEATER VENT FLUE, DETAILS BY PLUMBING ENGINEER
6 REVISIONS Arizona Office E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
7 REVISIONS Arizona Office E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
8 REVISIONS Arizona Office 1717 E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
9 REVISIONS Field Wired and Piped From building water supply Roof line B Normally closed valve PRESSURE SWITCH B R OVERFLOW SWITCH W R W Normally open valve To building drain A1 15 E P TIMER A A Internal Water Solenoid Arizona Office 1717 E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
10 REVISIONS Arizona Office E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) DATE: DWG.#: DRAWN BY: SCALE: Room Temperature Sensor -Wall mounted under HVAC Thermostat or at least 10' away from hood. MASTER DRAWING SHEET NO.
11 REVISIONS AIR FLOW AIR FLOW Arizona Office E. Bell Road, SUITE 12, Phoenix, AZ, PHONE: (480) FAX: (877) DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
12 SS1 SS1 SS1 SS A SS SS1 D SS5 400 E SS4 SS4 405 SS1
13 WALK - IN SPECIFICATIONS U} L Outdoor Walk-in Cooler/Freezer Combo OVERALL SIZE: 7'-9" X 14'-6" X 8'-6 1/4" A089369R1 001 N/A DRAWING #: UNIT #: ORDER #: 7'-9" PANELS FOAMED IN PLACE URETHANE FOAM 4" 7'-1" EXTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA FLOOR: GALVALUME - EMBOSSED 26 GA INTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA FLOOR TYPE F01 FREEZER : ALUMINUM - SMOOTH ALUMINUM.100 C01 COOLER : SCREED, METAL 4" HIGH WALK-IN ACCESSORIES (2) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) LOT, ROOF CAP - SLOPED MEMBRANE FLASHED (SLOPE 1/4" PER FOOT) (1) LOT, TAPCON FASTENERS (1) LOT, RACKING CLIP (1) LOT, TIE DOWN ANGLE - 1/4" X 3" X 4" X 96" (W-IN CL TO BUILDING) (30) LF, COVE BASE, GALVALUME EMBOSSED 26 GA 1.25 X 4.25 F01 - FREEZER : W/FLOOR 8' - 6 1/4" O.A. HEIGHT 7' /8" I.D. 15" " 1 4 " " 5' " Kolpak TM 2915 Tennessee Avenue North, Parsons, TN (731) *(800) * A Manitowoc Company REFRIGERATION PC199LOP-2 VOLTS: ,BTU:5845 EL EC-PR-4 VOLTS: ,BTU:7200 TEMP: WALK-IN -10,AMBIENT TEMP: 115 (1) RACK 1 TIER B LINE RDI " 1 2 " 14'-6" 1 PC99MOP-2 VOLTS: ,BTU:7799 AM EC-PR-4 VOLTS: ,BTU:8700 TEMP: WALK-IN 35,AMBIENT TEMP: 115 (1) RACK 1 TIER B LINE RDI C01 - COOLER : NO FLOOR 8' - 6 1/4" O.A. HEIGHT 8' - 2 1/4" I.D " A " " 15" 8' " 8' " CENTER TO END NOTE: DOOR JAMB EXTENDS DOWN PAST SCREEDS TO FLOOR. 2 TEMPLE BETH TEFILLAH D10 N/A SCOTTSDALE,AZ USA! ATTENTION FOR APPROVAL SPACE DESIGNATED 1. DRAWING NOT INTENDED FOR INSTALLATION - DESIGN APPLICATION ONLY. 2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE 3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS 4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES 5. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION 6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS 7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS 8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE 9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES 10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB-SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT. 11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 915 f; SPONTANEOUS IGNITION TEMPERATURE RATING: 950 f " B 46" X 84" MIN. MASONRY OPENING WALLS LAYOUT " YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS, FINISHES, DOORS SIZES, LOCATIONS AND SWINGS APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS DRAWN. APPROVED AS NOTED- MAKE REQUIRED CHANGES AND MANUFACTURE AS DRAWN. NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING REVISION AND RESUBMISSION. DATE: BY: TOPS LAYOUT SMOOTH FINISH DISCLAIMER Panels with non-textured and/or no-profile panel finishes (smooth finishes) on the exterior and interior faces may exhibit oil canning" and flatness imperfections on the surface. Our standard panels have a stucco embossed texture on both faces that helps to reduce oil canning and any other irregularities in the exposed surface. Please be aware of this potential situation in your specification process. Such oil canning and flatness issues are typical and are not covered under standard warranties " 46" " 7'-5" CENTER TO CENTER FLOORS LAYOUT FOR ENGINEERS SEAL DRAWN BY: DATE: CHECK BY: DATE: QUOTE REVISION DATE: JTT DWP SHEET # AD-1 of 2
14 3' " 3' " FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (STD) (1) THERMOMETER - 2 INCH DIAL W/6' LEAD (STD) (1) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) VENT - PRESSURE RELIEF, HEATED KASON 1825 (STD) (1) CENTER DOOR SECTION LIGHT OVER DOOR (3) HINGE - KASON 1345 ADJUSTABLE / SPRING ASSISTED (STD) (1) HANDLE - KASON 28 WITH LOCKING ASSEMBLY (STD) (1) DOOR CLOSER - KASON 1098 W/COVER AND HOOK (STD) (1) HEATER WIRE, 2.5 WATT / FT (1) THRESHOLD, STAINLESS STEEL 14 GA (1) RAMP INTERIOR 34X20 4' " 3' " FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (STD) (1) THERMOMETER - 2 INCH DIAL W/6' LEAD (STD) (1) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) CENTER DOOR SECTION LIGHT OVER DOOR (3) HINGE - KASON 1345 ADJUSTABLE / SPRING ASSISTED (STD) (1) HANDLE - KASON 28 WITH LOCKING ASSEMBLY (STD) (1) DOOR CLOSER - KASON 1098 W/COVER AND HOOK (STD) ADJACENT BUILDING WALL 1/4" x 1-3/4" TAPCON ANCHOR HEX WASHER HEAD; USE 3/16" x 4-1/2" CONCRETE DRILL, TAPCON BIT # OR EQUAL ( ) TAPCONS ARE 9" O.C. WITH MIN 1-1/4" EMBEDMENT. FLASHED ROOFCAP TRIM L3" x 4" x 1/4" 6063-T6 PAINTED ALUMINUM ANGLE ( ) SILICONE BEADS MEMBRANE ROOF SLOPED INSULATION A089369R1 001 N/A DRAWING #: UNIT #: ORDER #: DW-1 A DW-2 B 1/4" x #14 x 2" HEX WASHER HEAD TEK SCREW ( ) (6" ON CENTER) Kolpak 2915 Tennessee Avenue North, Parsons, TN (731) *(800) * A Manitowoc Company TM 8 DETAIL - TIE DOWN ANGLE-WALK IN CLTO BUILDING-OUTDOOR TRIM ANGLE TRIM ANGLE (FLASHED) ROOF MEMBRANE 4" 1 COMPARTMENT DESCRIPTION TEMP F WI QTY MODEL# DIMENSIONS COMPRESSOR TYPE L (A) W (B) H (C) LBS HP CONDENSING UNIT RLA COMPRESSOR LRA V HZ Ф CONDENSER FAN MTR CONNECTIONS O.D. RCV CAP TOTAL MX AMP FLA V Ф AMPS DISC SUCT 90% FULL (lbs) Freezer PC199LOP-2 Hermetic /8 3/ Cooler 35 1 PC99MOP-2 Hermetic /8 3/ COMPARTMENT DESCRIPTION Freezer Cooler DOOR DETAIL - 4IN FLOOR-RAMP SWEEP GASKET HEATER WIRE BOTTOM PLATE S/S THRESHOLD FLOOR PANEL TEMP F WI QTY 2 DOOR DETAIL - FLAT BOTTOM SWEEP GASKET FLAT BOTTOM WALL FINISHED FLOOR MODEL # DIMENSIONS (DEFROST: A-AIR E-ELECTRIC) L (D) W (E) H (F) LBS 3 FLOOR OR METAL SCREED UNIT COOLER AMP FAN V IF REQUIRED, PLACE LEVELING SHIMS AT EACH SCREW LOCATION TO MAINTAIN A LEVEL FLOOR. AMP HEATER 1/4" x 4" TAPCON ANCHOR, PHILLIPS FLAT HEAD. USE 3/16" x 6-1/2" CONCRETE DRILL BIT # OR EQUAL; DRILL THRU HOLE. V Ф SUCT CONNECTIONS O.D EL EC-PR /8 3/8 3/ AM EC-PR N/A 0 7/8 3/8 3/4 LATCH STRIKE DETAIL - PANEL CONNECTION AT FLOORS OR METAL SCREEDS 4 WALL PANEL FINISH FLOOR FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR WITH FLOOR FLOOR PANEL 1-1/4" MIN LIQ IF REQUIRED, PLACE LEVELING SHIMS AT EACH SCREW LOCATION TO MAINTAIN A LEVEL FLOOR. 5 FINISH FLOOR FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR DRAIN 1/4" x 4" TAPCON ANCHOR, PHILLIPS FLAT HEAD. USE 3/16" x 6-1/2" CONCRETE DRILL BIT # OR EQUAL ( ); DRILL THRU HOLE. METAL SCREED ELECTRICAL CONNECTIONS (IN REAR) 1-1/4" MIN CONDENSING UNIT ASSEMBLY AIR INLET B D A LIQUID CONNECTION (IN REAR) SUCTION CONNECTION (IN REAR) C SUCTION AND LIQUID LINE EVAPORATOR - MODEL AM, EM, EL, AMB, ELB E MPT DRAIN SLOPED FOAM INSULATION SLOPE = 1/4" PER FT 7 6 F DETAIL - SLOPE MEM ROOF CAP FLASHED F M M F 18" CEILING PANEL WALL PANEL LOCKS STRIKES RACKING CLIPS DETAIL - RACKING CLIP FLOOR PANEL OR SCREED CLEARANCE REQUIREMENT MINIMUM CLEARANCE REQUIRED FOR PROPPER OPERATION SIDE VIEW 36" REQUIRED FOR SERVICING AIR FLOW TEMPLE BETH TEFILLAH D10 N/A SCOTTSDALE,AZ USA QUOTE REVISION DATE: DRAWN BY: DATE: CHECK BY: DATE: JTT DWP SHEET # AD-2 of 2
FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN
PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY
More information900 N. Via Piemonte Ontario, CA
2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:
More informationDES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.
DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT 806 E. Hoffman Street Des Moines, IA 50316 ADDENDUM NO. 1 April 3, 2017 Item 1: Item 2: Item 3: Item 4: See attached sketch showing the
More informationINSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)
SECTION 11400 INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS) PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Pre-fabricated, free standing walk-in cooler/freezer rooms, metal clad, designed
More informationroof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required
ITEM NO. PROJECT LOCATION DATE QTY. Quick Ship Walk-In Coolers & Freezers With Matching Refrigeration Systems FREE FREIGHT to domestic U.S. locations and select locations in Canada (consult your Master-Bilt
More information10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS
ITEM NO. PROJECT LOCATION DATE QTY. 10-Bilt Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS CONSTRUCTION Models ship within 10 working days after order is received 4" thick
More informationINSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)
SECTION 11400 INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS) PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Pre-fabricated, free standing walk-in cooler/freezer rooms, metal clad, designed
More informationNOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016
NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers
More informationStandard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4290 FAX www.norlake.com Kold Locker Walk-Ins Standard
More informationAmerican Panel. Walk-In Installation & Maintenance Manual
American Panel Walk-In Installation & Maintenance Manual OUR COMMITMENT TO YOU Thank you, and congratulations on your purchase of an American Panel walk-in. We take great pride in engineering and manufacturing
More informationWall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.
Wall mount refrigeration systems available PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations PRS-2: The Keyword Is Simple Simple Convenience The PRS-2 series combines durable walk-in panels
More informationQUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE
SEE INSIDE QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems The Quick Answer To Walk-In Needs In a hurry for a walk-in cooler or freezer? Master- Bilt s Quick Ship Program is the
More informationHVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION
GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint
More informationKold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT
7750 Georgetown Rd. Indianapolis, IN 46268 800 215 9293 www.centralrestaurant.com Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT Stock No. 185 029 Walk in is located indoors, 4" thick
More informationWall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations
Wall mount refrigeration systems available PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations PRS-2: The Keyword Is Simple Simple Convenience The PRS-2 series combines durable walk-in panels
More informationMINI-ROOM COOLERS, FREEZERS & COMBINATIONS
NOR-LAKE SCIENTIFIC 727 Second Street Hudson, Wisconsin 54016 800-477-5253 7-386-2323 866-961-5253 Parts 800-388-5253 Service 7-386-4290 FAX www.norlakescientific.com SCIENTIFIC Mini-Room Walk-In Controlled
More informationWalk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details
Walk-in Refrigerated Rooms An Overview of Requirements, Options and Construction Details Definition A refrigerated room is a stand alone structure designed to hold products at either a medium temperature
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationINSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS
INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions
More informationCABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR
CABINET PARTS REFRIGERATOR 03 07 Litho In U.S.A. (mat) 1 Part No. Rev A CABINET PARTS 1 Literature Parts 2261383 Use & Care Guide 2255955 Service & Wiring Sheet 2261377 Energy Guide 2220407 Modular Icemaker
More informationFood Service Plan Review Information
Food Service Plan Review Information New or remodeled food preparation facilities, and those changing ownership, must undergo a plan review process prior to a health permit being issued. The purpose of
More informationCABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)
CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 4 12 Litho In U.S.A. (mlg)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303987 Use & Care Guide W10205624 Energy Guide W10483322 Service
More informationInstallation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street
Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US or
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationGen II Entree Bath - All Models
Gen II Entree Bath - All Models Installation Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Important safety instructions. Read and follow all instructions thoroughly. CAUTION:
More informationWineZone Ceiling Mount Ductless Split 15
WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationNew RepairBase Line Item additions for the Update
Equipment Rental Equipment Rental Scissor Lift Does not Include Operator Charge Per Day Equipment Rental Compact Tractor Does not Include Operator Charge Per Day Equipment Rental Trenching Machine Does
More informationCABINET PARTS REFRIGERATOR
CABINET PARTS REFRIGERATOR 1 94 Litho In U.S.A. 1 Part No. CABINET PARTS 2 2152011 Front Roller (2) 3 489393 Screw, 4 981122 Roller (Rear) (2) 5 488454 Screw 6 2155013 Clip, Grille 7 489242 Screw 9 836196
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationOne of the most popular units within the inventory
Over-and-Under Refrigerator Freezer Front venting allows unit to be completely built in Hermetically sealed refrigeration units Lighted electronic control panel Serial and model number plate Adjustable
More informationCABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No " BOTTOM MOUNT BUILT IN REFRIGERATOR
CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 9 05 Litho In U.S.A. (kdj) 1 Part No. 1 Literature Parts LIT2266810 Use & Care Guide LIT2266819 Energy Label LIT2266830 Service & Wiring Sheet LIT628370
More informationCanning Shed/Facility Equipment Specifications
Canning Shed/Facility Equipment Specifications Item Qty Description 1 1 ea WALK IN COOLER Fast Trak Indoor One Compartment Walk In, 8' x 8' x 7' 7" H, compartments, cooler with smooth aluminum interior
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)
More informationPlease call for current pricing, additional information, or with any questions.
http://www.aluminumtrailer.com ADVANTAGE TRAILERS & HITCHES 110 E. North Ave. Carol Stream, IL 60188 888-280-6695 www.advantagetrailer.com MODEL INFO Configured Model #: QSTAG8536+0-2T7.0K Quest Aluminum
More informationWalk-Ins & Refrigeration Systems
Walk-Ins & Refrigeration Systems Quality Engineered Refrigeration Since 1947 Kold Locker Fast-Trak Fineline 2 Walk-Ins Kold Locker Over 10,000 Kold Locker walk-in configurations are in stock and ready
More informationSCN60 Residential Nugget Ice Machine
SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared
More informationProduct/Feature Energy-Saving Function Where Used
Master-Bilt initiated our Energy Saver program to help you quickly identify features that serve your efficiency needs. Below is a list of features and options included in the program. See http://master-bilt.com/customer-support/energy-savers
More informationCABINET PARTS. For Models: GD2SHAXNQ00, GD2SHAXNT00, GD2SHAXNB00, GD2SHAXNS00, GD2SHAXNL00 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)
CABINET PARTS REFRIGERATOR 5 04 Litho In U.S.A. (kdj) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts 2261717 Use & Care Guide 2255955 Service & Wiring Sheet 2305881 Energy Guide 2220407 Modular Icemaker
More information4 04 Printed In U.S.A. (kdj) 1. Part No REFRIGERATOR
CABINET PARTS REFRIGERATOR 4 04 Printed In U.S.A. (kdj) 1 Part No. CABINET PARTS LITERATURE PARTS 1 2305802 Use & Care Guide 2301270 Service & Wiring Sheet 2305630 Energy Label 2220407 Modular Icemaker
More informationFOOD SERVICE May 6, 2016
FOOD SERVICE May 6, 2016 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and any requirements that may differ from the prototype requirements
More informationKSRG25FKWH18, KSRG25FKBL18, KSRG25FKBT18
CABINET PARTS REFRIGERATOR 06 06 Printed In U.S.A. (kdr) 1 Part No. CABINET PARTS 1 Literature Parts 2318581 Use & Care Guide 2255385 Service & Wiring Sheet 2318618 Energy Guide 2220407 Modular Icemaker
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationCABINET PARTS For Model: KSSO36FMX01 (Etched Aluminum)
CABINET PARTS 36" BUILT IN REFRIGERATOR 9 05 Litho In U.S.A. (kdj) 1 Part No. 1 Literature Parts 2266808 Use & Care Guide 2307362 Energy Label 2306324 Service & Wiring Sheet 2306337 Icemaker and Ingredient
More informationInstallation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515
Installation 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515 TABLE OF CONTENTS Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom
More informationB E ROUTE DUCT BEHIND BOOKSHELF. GRILLE MOUNTED ON TOP OF BENCH. BOOK CASE WALL 12x8 8x5 I 8"Ø 7"Ø 125 CFM I D M FLOOR SIDE WALL VENT 6x5 160 CFM 6"Ø 6"Ø 8x10 J C G 1 Section M-1 NOT TO SCALE Project No
More informationThe Ultimate Home Maintenance Schedule
The Ultimate Home Maintenance Schedule On-Going Quarterly Maintenance Schedule Check interior and exterior faucets for leaks. Clean aerators. Replace washers if Clean with baking soda. Pour water down
More informationCABINET PARTS. For Models: GS5SHAXNQ02, GS5SHAXNT02, GS5SHAXNB02, GS5SHAXNS02, GS5SHAXNL02 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)
CABINET PARTS REFRIGERATOR 10 05 Printed In U.S.A. (kdr) 1 Part No. CABINET PARTS 1 Literature Parts 2305895 Energy Guide 2315213 Owner s Manual 2255955 Service & Wiring Sheet 2220407 Modular Icemaker
More informationCABINET PARTS For Model: KBLC36FMS02 (Stainless Steel)
CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 11 05 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Literature Parts 2317085 Use & Care Guide 2307361 Energy Label 2306322 Service & Wiring Sheet
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationE-CDR48-PL-0413 REVISED STARTING SERIAL # PARTS LIST MANUAL 48 CORE DRILL RIGS. EdcoParts.com
E-CDR48-PL-0413 PARTS LIST MANUAL 48 CORE DRILL RIGS REVISED STARTING SERIAL # 130410266 EdcoParts.com SKU # MODEL # VACUUM PUMP DRILL MOTOR SPEED/RPM 97100EV 4820 INCLUDED MILWAUKEE DYMO DRILL 2 SPEED
More informationGlass Door Merchandiser. Model RM-49
Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationKR Electrical Defrost Unit Coolers (PN E108318_E)
KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN
More informationAPPENDIX 3J FOOD SERVICES SPECIFICATIONS
APPENDIX 3J FOOD SERVICES SPECIFICATIONS 1. FOOD SERVICES 1.1 Design Consultant Project Co will retain as part of its professional design team a qualified food service consultant that is a professional
More informationClosing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear
Electrician Meter Box Cover Closes Breaker Works Meter Reading Surge Protector Breaker Boxes All Work GFCI Test OK All Labeled Spare Slots Available Hot Tub Breaker Box Cover Closes All Work All Labeled
More informationFood Service Establishment Plan Review Form
CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us Food Service Establishment Plan Review Form THE FOLLOWING INFORMATION
More informationPGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT
PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed
More informationFOOD SERVICE May 6, 2016
FOOD SERVICE May 6, 2016 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype requirements
More informationSPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS
SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS GENERAL Standard walk-in panels to be constructed of 4, 5", 6",8",10" or 12 thick prefabricated panels. PANEL CONSTRUCTION Panels consist of die-formed interior
More informationHOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION
HP1H-M-SN HP1V-M-SN HPH-M-SN HPV-M-SN HOLDING/PROOFING CABINETS APPLICATION To satisfy a need for high quality, shipboard grade, heated products, Cospolich has introduced their "HP" class of horizontal
More informationThe following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on
HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and
More informationEXPLODED VIEWS & PARTS LISTS
561 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationReplacement Parts List For Models COS-20G
Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components
More informationRaul Aragon. manufacture warranty
SOCORRO INDEPENDENT SCHOOL DISTRICT Summary Sheet Contracted Services for Food Service Equipment, Repair Parts and Materials CSP No. 199-0829-E1305 Awarded: October 16, 2012 Expires: October 16, 2013 Extended:
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationCABINET PARTS For Models: KSRG22FKWH17, KSRG22FKBT17, KSRG22FKBL17 (White) (Biscuit) (Black)
CABINET PARTS REFRIGERATOR 5 06 Litho In U.S.A. (kdr) 1 Part No. CABINET PARTS 1 LITERATURE PARTS 2315214 Use & Care Guide 2255385 Service & Wiring Sheet 2315352 Energy Label 2220407 Modular Icemaker Service
More informationDrop-In Refrigeration System
Drop-In Refrigeration System Original Instructions Installation, Operation and Maintenance Manual This manual is updated as new information and models are released. Visit our website for the latest manual.
More informationCMHC HOME MAINTENANCE CHECKLIST
Make sure air vents indoors and outdoors (intake, exhaust and forced air) are not blocked by snow or debris. Check and clean range hood filters on a monthly basis. Test ground fault circuit interrupter(s)
More informationPREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F
PREPARED FOR: l (Name of Client) CONCERNING: (Address of Property) BY: (Name of Technician) (Consultation Date) YOUR HOME CHECK 1305 FM 359, Suite G Richmond, TX 77469 P 281-342-Home F 281-342-4669 I.
More informationCABINET PARTS For Model: KBLC36FTS04 (Stainless Steel)
CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 10 11 Litho In U.S.A. (mlg) (eeb) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303987 Use & Care Guide W10205624 Energy Guide W10159833 Service
More information20/20 Home Inspections. Photo Attachments
Page 1 of 9 Damaged roof shingles. Improper rof shingle installation; improper overlapping. Improper layout. Improper flashing at plumbing vent stack. Wrong size jack. No storm collar. Improper installation
More informationENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL
ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance
More informationFront Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim
2 2174748 Front Roller (2) 3 489456 Screw 4 981122 Roller (Rear) (2) 5 489427 Screw 6 2155013 Clip, Grille 7 489478 Screw 9 2156056 Shim 12 2196046 Hinge Top (2) 13 2196048 Shim, Hinge Top 14 489284 Screw
More informationInstallation Instructions
Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2060/2061 7082 485-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and
More informationWHIRLPOOL REFRIGERADOR GS2SHGXLQ01
CABINET, LITERATURE 1 CABINET, LITERATURE 1 LIT2220425 LITERATURE PARTS (Energy Label) 1 LIT2220699 LITERATURE PARTS (Owner`s Manual) 1 LIT2255381 LITERATURE PARTS (Service & Wiring Sheet) 1 LIT628370
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at
More informationFront Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Insert, Air
2 2174748 Front Roller (2) 3 489456 Screw 4 981122 Roller (Rear) (2) 5 489427 Screw 6 2155013 Clip, Grille 7 489242 Screw 8 2176796 Insert, Air Baffle 9 2156056 Shim 10 2158579 Enclosure, Terminal Block
More informationCABINET PARTS REFRIGERATOR. For Models: ED25PQXFW00, ED25PQXFN00 (White) (Almond) Litho In U.S.A. (mdg) 1. Part No
CABINET PARTS REFRIGERATOR 11 97 Litho In U.S.A. (mdg) 1 Part No. CABINET PARTS 2 2174748 Front Roller (2) 3 489456 Screw 4 981122 Roller (Rear) (2) 5 489427 Screw 6 2155013 Clip, Grille 7 489478 Screw
More informationCanadian Property Inspections
Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.
More informationCABINET PARTS REFRIGERATOR. For Models: GD2SHAXKQ03, GD2SHAXKT03, GD2SHAXKB03 (White) (Biscuit) (Black) 5 02 Litho In U.S.A. (mek) 1. Part No.
CABINET PARTS REFRIGERATOR 5 02 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 LITERATURE PARTS LIT2220699 Use & Care Guide LIT2220104 Service & Wiring Sheet LIT2220300 Energy Guide LIT2220407 Modular
More informationCABINET PARTS For Model: KBFC42FTS03 (Stainless Steel)
CABINET PARTS 42" BOTTOM MOUNT BUILT IN REFRIGERATOR 7 08 Litho In U.S.A. (mjb)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts 2320682 Use & Care Guide W10205809 Energy Guide W10159834 Service
More informationCABINET PARTS REFRIGERATOR. For Model: KSRS25FGSS11 (Stainless Steel) 6 00 Printed In U.S.A. (mdg) Part No Rev.B
CABINET PARTS REFRIGERATOR 6 00 Printed In U.S.A. (mdg) 1 Part No. Rev.B CABINET PARTS LITERATURE PARTS 1 LIT2206106 Use & Care Guide LIT2200278 Service & Wiring Sheet LIT2211866 Energy Guide LIT628370
More informationEXPLODED VIEWS & PARTS LISTS
542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationKSSS42QDW05, KSSS42QDX05
CABINET PARTS 42" BUILT IN REFRIGERATOR 4 97 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Cabinet (Not A Serviceable Part) 3 2005004 Grommet, Tube Crossover 4 1112023 Roller, Front & Rear (4) 5 Support,
More informationWKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WWW.BREEZAIRE.COM WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More information2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS
City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationCABINET PARTS For Models: ED25UEXHW01, ED25UEXHT01 (White) (Biscuit)
CABINET PARTS REFRIGERATOR 9 00 Litho In U.S.A. (dmz) 1 Part No. CABINET PARTS 1 LIT2205958 Use & Care Guide LIT2204338 Service & Wiring Sheet LIT2211832 Energy Guide LIT628370 Modular Icemaker Service
More informationInspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc
Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include
More informationET14JKXAW01, ET14JKXAN01, ET14JKYAW01, ET14JKYAN01
DOOR PARTS REFRIGERATOR 9 97 Litho In U.S.A. 1 Part No. Rev.A DOOR PARTS 1 Refrigerator Door Panel (Also Order Item 11) 9790362 White 9791629 Almond 2 End Cap 9791773 White 9791774 Almond 3 Hole Plug (2)
More informationWhen considering the purchase of a walk-in you most likely will be looking for the following things.
BUYING A WALK-IN COOLER OR FREEZER When making a decision on which walk-in cooler or freezer to buy, there are many things that must be considered. In the following guide we hope to go through all these
More informationWHIRLPOOL REFRIGERADOR KSRS25FGSS13
CABINET, LITERATURE 1 CABINET, LITERATURE 1 LIT2206106 Literature Parts (Use & Care Guide) 2 2174748 Front Roller (2) 3 3400517 Screw 4 2196236 Roller (Rear) (2) 5 489427 Screw 6 2155013 Clip, Grille 7
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationGlass Door Merchandiser
Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT
More information