AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM
|
|
- Stephen Kelly
- 5 years ago
- Views:
Transcription
1 Guangzhou Junliye Import&Export Co., Ltd. AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM
2 OPERATION MANUAL 1. Cautions: Wear the glove and eye protection glass to protect the skin and eyes from refrigerant. Operating near the fire and spark is prohibited. Don t expose this device into sunshine or rain. Avoid to contact with corrosive liquid and gas. Keep good ventilation of workshop. 2. Notation: 2.1. Warnings Read the manual carefully before using this device. Only for R134a. Check the refrigerant type before operation. The real working capacity of refrigerant cylinder should be 80% of its efficient capacity, to avoid the serious accident result from high pressure. Be sure that the high and low manual valve is off before connecting the device to the air conditioner. Don t put the hose near rotation and heating automobile parts such as electronic fan and radiator. Check the vacuum pump oil level in fixed period. The start times of recovering process should be less than 10 in one hour otherwise the compressor will be damaged. Don t let the child and people of insufficient mental development close with this device when it is running. Only for expert professional. Don t disassemble device without permission of manufacture. Don t put this device upside down. The refilling process would not work if the refrigerant in cylinder less than 1Kg. The working voltage is 220V, NEVER USE 380V voltage 1
3 2.2 Preparation before using: Loosen the nut as indicated. The nut is used to protect the scale from vibration during the transportation. We need to move the nut before we use this machine. There are two holes at the back of the machine. And we need to use a tool to loose the hex(agonal)screw. Please see the picture in the right. 3. Technical parameter: Refrigerant type: R134a Work temperature: Power supply: AC 220V/60Hz Digital weight scale precision: 0.2%(FS) Speed of vacuumizing: 10.8M3/Hour Refrigerant cylinder capacity: 15Kgs Speed of recovering: Speed of refilling: 400g/min 1000g/min Net weight: Size(mm): 115Kg 790*640*1360mm 2
4 4. Device description: JLY540 is applied to R134a refrigerant handling. It can do the job of recovery, Vacuum, Leakage hunting, refilling and oil draining. Database for popular automobiles are available from this system. And also the operation result can be printed by the built-in printer. 4.1 Functions 1) Recovery: Recover the refrigerant from the A/C system and do refreshing before restore it into the cylinder, so it will avoid refrigerant contamination. 2) Vacuumizing: Vacuumize the A/C system, exhaust the moisture and air inside. 3) Refilling: Refill the refrigerant from the cylinder into the A/C system accurately. 4) Oil refilling: Renew the lubricant in the A/C system 5) Oil draining: automatically drain all the residual oil and purify that separated from the refrigerant during recovery. 6) Leakage hunting: Check if there is any leakage source by vacuum. 7) Air purge: exhaust the un-condensable gas. 3
5 4.2 Appearance Control panel High side & Low side connectors Oil draining bottle Fresh oil entry 4
6 4.3 Control Panel Cylinder Pressure Gauge LCD Printer Low Pressure Gauge Switch 4.4 Map of the key pad High Pressure Gauge ( ) ( ) ( ) ( ) Exit Increase Decrease Enter Start on Start off 5
7 4.5 Interior Structure Vacuum pump Oil separator Charge hose Fresh oil bottle Cylinder Compressor 5. Manual Operation Method 5.1 Recovery Operation Step 1) Link red hose to the HP terminal and blue hose to LP terminal of JLY540, connect up another side with red and blue quick adaptors and close off these two adaptors at the same time. Then connect these adaptors to the A/C system, LP and HP side separately. Turn on the adaptors. 2) Upplug to 220V/50~60HZ power and switch on. Message reads: 6
8 = = = FUNCTTON = = = CYL.: XX.XX KG 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 3) Press or to select MANUAL, then press to enter next step: = = = MANUAL= = = CYL.: XX.XX KG 1.RECOVERY 2.VACUUM 3.CHARGE 4.VACUUM HUNTING 4) Press or and choose RECOVERY, then press to enter: ---RECOVERY--- STOP CYL.: XX.XXKG SET REAL REC. : xx.xx.kg REC : xx.xxkg 5) Press or to set the recovery amount, then press ON to start: ---RECOVERY--- RUN CYL.: XX.XXKG SET REAL REC. : xx.xx.kg REC : xx.xxkg 7
9 Remark: Press Off to stop the recovery program When the HP & LP hoses pressure is close to zero, the system will automatically enter the program of oil draining and remind to print or not. Messages come out : --- RECOVERY STOP--- CYL.: XX.XX KG SET REC. : xx.xx.kg REAL REC. : xx.xxkg NOTE: RECOVER FINISH, PRINTING? When the setting amount is equal to the real recovery amount, recovery program stops automatically. 5.2 Self-protection during the recovery process 1) When the HP hose and LP hose pressure is below 0.15MPA, the system will refuse to execute the command of recovery. And it will indicate that NO REFRIGERANT IN HOSE. 2) When the total recovery amount comes to 200KG, system will suggest to replace the filter drier. Users should re-set the recovery amount to be zero when they have changed a new one. 3) During the recovery, the system can stop automatically when cylinder pressure (CP pressure) is high to 1.75MPA. It will indicate CYLINDER PRESSURE HIGH. We cannot restart the recovery program until the pressure decreases to 1.3MPA. 4) The capacity of the cylinder is 15KGS. When there is no space any more, the system will refuse to recover. 5) Long time working can cause high temperature inside the equipment, and may cause the problem of failing to restore the refrigerant in the cylinder. In this case, please wait 15 minutes before you re-start recovery program. 8
10 5.3 Operation steps of vacuumizing and refrigeration oil refilling 1) Open the door at your right side before refilling. Twist off the cap of the funnel, then put oil into the oil bottle by the funnel. 2) Connect red hose to HP side and blue hose to LP side of the A/C system 3) Power on, and window indicates: = = = FUNCTTON = = = CYL.: XX.XX KG 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 4) Press or to come to MANUAL, then press to enter next step: = = = MANUAL= = = CYL.: XX.XX KG 1.RECOVERY 2.VACUUM 3.CHARGE 4.VACUUM HUNTING 5) Press or, choose VACUUM, press to enter next step: --- VACUUM --- STOP CYL.: xx.xxkg SET VAC. TIME : xx : xx MIN SET OIL CHARGE : xxxx g REAL VAC. TIME : xx: xxin REAL OIL CHARGE : xxxx g 9
11 6) Press to select the setting target, press or to set the parameter 7) When finish setting, press ON to vacuum or refill refrigeration oil. Remark: When there is no need to refill oil, please set the parameter to be 000g When need to refill oil, set the weight you want. And windows indicates as below: --- VACUUM --- RUN CYL.: xx.xxkg SET VAC. TIME : xx : xx MIN SET OIL CHARGE : 0000g REAL VAC. TIME : xx : xx MIN REAL OIL CHARGE : 0000g NOTE: CHARGING OIL When the oil is already charged, Press to exit, press to print When the pressure in the A/C system is high to 1.5MPA or above, the system will refuse to accept the order of vacummizing and also indicates HOSE PRESSURE TOO HIGH. 5.4 Operation steps of charging 1) Connect the HP hose (red) and LP hose (blue) to the corresponding side in the A/C system. 2) Power on, and window indicates: = = = FUNCTTON = = = CYL.: XX.XX KG 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 10
12 3) Press or for MANUAL, then press to enter next step: = = = MANUAL= = = CYL.: XX.XX KG 1.RECOVERY 2.VACUUM 3.CHARGE 4.VACUUM HUNTING 4) Press or for CHARGE, then press to enter next step: ---CHARGE--- STOP CYL.: XX.XXKG SET REAL CHARGE. : xx.xx.kg CHARGE : xx.xxkg 5) Press or to set the charging amount, then press ON to enter the charge program. Press to exit, or press to print. ---CHARGE--- STOP CYL.: XX.XXKG SET REAL CHARGE. : xx.xx.kg CHARGE : xx.xxkg NOTE: CHARGE FINISH, PRINTING? Remark: Refrigerant must be more than 1KG for starting the recharge program. Otherwise, it cannot work. When the charging speed is too slow, the system will suggest to Swith on A/C. 11
13 5.5 Operation steps of leakage hunting 1) Connect the HP hose (red) and LP hose (blue) to the corresponding side in the A/C system 2) Power on, and window indicates: = = = FUNCTTON = = = CYL.: xx.xxkg 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 3) Press or for MANUAL, then press to enter next step: = = = MANUAL= = = CYL.: XX.XX KG 1.RECOVERY 2.VACUUM 3.CHARGE 4.VACUUM HUNTING 4) Press or for VACUUM HUNTING, then press to enter next step: --- LEAK --- STOP CYL.: xx.xxkg SET VAC. TIME : xx : xx MIN REAL VAC. TIME : xx : xx MIN SET LEAKH TIME : xx : xx MIN REAL LEAKH TIME : xx : xx MIN 12
14 5) Press to select the target, press or to set the parameter. When setting finished, press ON to start leakage hunting Remark: System will give out the result saying A/C NON LEAKAGE or A/C LEAKINGE When the pressure inside the A/C system is high to 1.5MPA or above, system will give message HOSE PRESSURE TOO HIGH and refuse to go on leakage hunting. 6. Automatic Operation The main functions involves vacuumize & charge, recover, vacuumize and charge. The automatic operation step is basically the same as manual operation. And the self-protection function in manual operation is also used to the automatic operation. 6.1 Operation steps to vacuum and charge 1) Connect red hose to HP side and blue hose to LP side of the A/C system. 2) Power on, and window indicates: = = = FUNCTTON = = = CYL.: XX.XX KG 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 3)Press or for AUTOMATIC, then press to enter next step: = = = AUTOMATIC = = = CYL.: xx.xxkg 1.VACUUM + CHARGE 2. RECOVERY + VACUUM + CHARGE 13
15 4) Press or for VACUUM+CHARGE, then press to enter next step: AUTO MODEL1 STOP CYL.: xx.xxkg SET VAC. TIME SET OIL CHARGE SET REF CHARGE : xx : xx MIN : xx.xx g : xx.xx KG 5) Press to select the target, press or to set the parameter. When finish setting, press ON to start vacuum and charging. Remark: When finish vacuumizing and charging, system will ask users to print or not. When we need to charge refrigeration oil, please firstly put oil into the oil bottle. Otherwise, please set the oil charge to be 0000g. 6.2 Operation method of recovery, vacuum and charging The operation step is basically the same as vacuum+charge. Please refer to vacuum+charge operation step. 7. The calibration of weight scale 7.1. The method of setting weight scale 1) Get the weight ready of 15.30kg 2) Remove the storage cylinder from the scale pan 14
16 3) Switch on and the LCD window as below: = = = FUNCTTON = = = CYL.: XX.XXKG 1.MANUAL 2.AUTOMATIC 3.DATABASE 4.BASIC OPERATTON 4) Press and button at the same while, window shows: = = =RESET = = = CYL.: XX.XXKG 1 DRYER AND FILTER 2.VACUUM PUMP OIL 3.SCALE 4.UNITS 5.STATUS: XXX KG 5) Press or to select SCALE, press and message comes out: = = =WEIGHT SCALE = = = CYL.: XX.XXKG 1 REFRIGERANT SCALE RESET 2.REFRIGERANT SCALE CALIBRATE 3.OIL SCALE RESET 4.OIL SCALE CALIBRATE 6) Press or to select REFRIGERANT SCALE RESET, press and a message saying that RESET IS FINISHED. Press or to choose REFRIGERANT SCALE CALIBRATE and the press : = = =CALIBRATE = = = CYL.: XX.XXKG REFRIGERANT WEIGHT SCALE: WEIGHT ON SCALE : XX.XXKG WEIGHT CALIBRATION: XX.XXKG 15
17 7) Press or, set the weight to be 15.30KG and then press, the window shows: = = =CALIBRATE = = = CYL.: 15.30KG REFRIGERANT WEIGHT SCALE: WEIGHT ON SCALE : 15.30KG WEIGHT CALIBRATION: 15.30KG Calibration is finished and press exit key to exit Calibration of refrigeration oil 1) Prepare a weight of 500g 2) Refer to 7.1. for the calibration step 8. Recall the Database The database is helpful to the technicians. It provides the data of all kind of popular automobile of the refrigerant charging amount refrigeration oil charging amount. It saves much time to the technicians. Power on and press or to choose DATABASE, press to enter and check. 9. Replace the filter drier The system will make total of the recovery amount automatically. When the amount comes to 200KG, the system will indicates the users to replace the filter drier. Replacement steps: 1) Must plug off, in order to avoid any electric shock 16
18 2) Remove the filter drier and install a new one. Pay attention the the direction when install. 3) Finishing the replacement, upplug and turn on the machine. Press in the same while, LCD window says: = = RESET = = = CYL.: xx.xx KG 1. DRIER AND FILTER: 2. VACUUM PUMP OIL : 3. SCALE: 4. UNITS STATUS: 000 KG Press or to selet DRIER AND FILTER, press to set zero of the filter drier lifetime. When finish setting, the status wil change to 200 KG. 10. Change Vacuum pump oil Must use the original pump oil or oil recommended by manufacture When the oil level is reach the minimum position, pump oil should be added. If the oil level is too high, it should be drained by unfastening the draining screw System could accumulate the vacuum time. When the value reach to 9000 minutes, system would remind changing the pump oil. The over would be displayed when the power is on and system would not start vacuum process. When the color of pump oil is changed to white, it must be changed. Change stage: 1:Before changing, run the vacuum process for 1 minute to be sure that the pump is in hot condition. Open the draining screw to drain the oil into a container. 2: Unplug the power cable and remove the backboard of device. Unfasten the oil entrance lid and add oil into the pump until the oil level is higher than the minimum position, fasten the screw. 3:After changing vacuum pump oil, it should switch the power on and press the 17
19 and key in same time to enter reset menu and press menu key to select vacuum oil item, press the and key in same time again to reset the working time. Guangzhou Junliye Import & Export Co., Ltd. ADD:Baiyun District,Guangzhou,China. Tel: Phone NO
AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM
AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL Index I Caution.... 2 II Notation.. 2 III Technical parameter...3 IV Functions... 3 V Device Description. 3 (I) Control panel. 4
More informationOwner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit
Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:
More informationMobile Air-Con Service Solution. AC7000 Operation Manual
Mobile Air-Con Service Solution AC7000 Operation Manual Cool-It Mobile HVAC Group Contents 1 About this operation manual.......................................... 2 1.1 Cool-It Hotline......................................................
More informationENSPECO Recovery/ Recycle/ Evacuate/ Recharge
ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover
More informationHybrid Conversion Kit Procedure Guide
Automotive Air Conditioning Hybrid Conversion Kit Procedure Guide TM autoclimate COPYRIGHT INFRINGEMENT NOTICE Autoclimate Limited. All rights reserved. No part of this manual, publication or text may
More informationBAC 4000a BAC 5000yf
AC Service Units BAC 4000a BAC 5000yf AC Service Units Recommended by Volvo Cars Fully-automatic, high capacity and comfortable Maximum safety Easy to use BAC 4000a Maximum precision easy operation. The
More informationRECOVERY/RECYCLE/RECHARGE
RECOVERY/RECYCLE/RECHARGE Operating Instructions 2 CONTENTS SAFETY SUMMARY 4 SAFETY INFORMATION 4 ELECTRICAL SHOCK HAZARDS 4 MOTION HAZARDS 4 FUME HAZARDS 4 HEAT/FREEZING HAZARDS 5 EXPLOSION/FLAME HAZARDS
More informationPro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System
Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Certified by ITS to meet SAE J2810 for R-134a Designed to meet new SAE J2851 for R-1234yf MANUAL GENERAL INFORMATION Table of
More informationRECOVERY/RECYCLE/RECHARGE
RECOVERY/RECYCLE/RECHARGE Operating Instructions WARNING!! Do not stop the recovery process. Permanent damage will occur that could void the warranty. INTRODUCTION This machine is ETL Laboratories approved,
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com User s Manual 1 WARNING! CAUTION! Before operating this unit, please read this
More informationUser manual Flushing device VAS 6337/1a
User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure
More informationRECOVERY/RECYCLE/RECHARGE
RECOVERY/RECYCLE/RECHARGE Operating Instructions WARNING!! Do not stop the recovery process. Permanent damage will occur that could void the warranty. CONTENTS INTRODUCTION 4 SAFETY SUMMARY 4 SAFETY INFORMATION
More informationAUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941
AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL Analyzer Part Number: 68941 Table of Contents FOR YOUR SAFETY:... 3 IDENTIFIER WARNINGS/GENERAL CAUTIONS... 3 WELCOME... 5 1 INTRODUCTION AND OVERVIEW...
More informationAutomotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD
Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...
More informationAriazone 601HD Refrigerant Recovery&Recycling unit
Automotive Air-Conditioning Service Equipment Ariazone 601HD Refrigerant Recovery&Recycling unit OPERATOR MANUAL 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before
More informationariazone 601HD Refrigerant Recovery & Recycling Unit User's manual
ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual Model: Ariazone 601 HD Serial No: 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before operating
More informationFULLY AUTOMATIC A/C SERVICE UNIT USE AND INSTRUCTION MANUAL
INDEX FULLY AUTOMATIC A/C SERVICE UNIT USE AND INSTRUCTION MANUAL INDEX PARAGRAPH TITLE DESCRIPTION VERSION PAGE N. GENERAL INFO PRELIMINARY INSTRUCTIONS, PROPER USE SW 1.3.X VER.1.0 3 INSTALLATION PREPARING
More informationOPERATION & MAINTENANCE MANUAL RHS680
OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationPDA20DX Air Purifying Dehumdifier Manual
PDA20DX Air Purifying Dehumdifier Manual Index Important Safe Guards Ambient Environment For Operating Components Diagrams---Parts Names Operating Introduction---How to operate - Functions of Control Panel
More informationFully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Prüftechnik ACS 600, 601, 650 Air conditioning service units from Bosch NEW! Ñ ACS 600 even the entry model is fully
More informationGreenTronic. for R1234yf (HFO) With built in Refrigerant Analyzer and Nitrogen Test device OPERATING MANUAL. Rev
GreenTronic for R1234yf (HFO) With built in Refrigerant Analyzer and Nitrogen Test device OPERATING MANUAL Rev00-1 - - 2 - CONTENTS 1 PREMISE...5 1.1 Information about refrigerant...6 2 SYMBOLS...8 3 INTENDED
More informationARIAZONE 5001 FAHD R-134a or R-1234yf DATABASE. Automotive Air Conditioning Service Station OPERATOR MANUAL
ARIAZONE 5001 FAHD R-134a or R-1234yf DATABASE Automotive Air Conditioning Service Station OPERATOR MANUAL 1 Contents Page 1. Introduction... 3 2. SAFETY FIRST! Important Safety Information's... 4 3. Technical
More information347002K/177002K/34900
Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing
More informationOPERATION & MAINTENANCE MANUAL AC860
OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...
More informationRefrigerant Recovery Machine. Model No Operating Manual
Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be
More informationAdvance Advance+ Preset
Advance Advance+ Preset User Manual Advance/Advance+ ~ 1 ~ Notes: User Manual Advance/Advance+ ~ 2 ~ CONTENT 1 PREFACE... 4 2 SYMBOLS... 4 3 FORESEEN USE... 5 4 SAFETY... 5 4.1 Glossary of Terms... 5 4.2
More informationOilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY
Pro-Set TR500 SERIES Oilless Refrigerant Recovery System OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR500, TR500E, TR500J, TR500S TO BE OPERATED
More informationRefrigerant Recovery/Recharging Series
TrustworthyBrandChinaChunMu Refrigerants TrustworthyBrandChinaChunMu 2012 Refrigerant /Recharging Series Portable Refrigerant /Recharging Unit Light Commercial HVAC Industrial Refrigeration System Automotive
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationOperation and Maintenance Manual
Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which
More informationRecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual
RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationDC200 Digital Dispenser Operating Manual
DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine
More informationEnspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS
Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning
More informationCOMPUTERIZED UNIT FOR RECOVERY, RECYCLING, VACUUM, CHARGE AND FLUSHING. User s manual ENGLISH
COMPUTERIZED UNIT FOR RECOVERY, RECYCLING, VACUUM, CHARGE AND FLUSHING User s manual ENGLISH Wigam spa reserves the right to discontinue, or change at any time specifications or designs without notice
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More informationA/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car
A/C Refrigerant Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car Refrigerants are HAZARDOUS to you and the environment Motor Vehicle Air Conditioning
More informationREFRIGERANT SYSTEM SERVICE WARNINGS
2005 HVAC Refrigerant System - MX-5 Miata REFRIGERANT SYSTEM SERVICE WARNINGS USING/HANDLING UNAPPROVED REFRIGERANT Using a flammable refrigerant, such as OZ-12, in this vehicle is dangerous. In an accident,
More informationUser s manual. SECU smart
User s manual SECU smart Note BEHR SERVICE reserves the right to discontinue, or change at any time specifications or designs without notice and without incurring obligations according to the company's
More informationOWNER S MANUAL (English)
TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE
More informationFluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE
Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems
More informationRequests for Daily Care and Maintenance
Inkjet printer SIJ-320UV Requests for Daily Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which the
More informationINSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold
LOW VAC INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold REF HIGH SPECIAL FEATURES Low battery indicator Displays 63 refrigerants Displays corresponding saturation, dew or bubble point temperature
More informationPerfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651
Bosch: bringing you the workshop of the future For over 125 years, Bosch innovations have been keeping vehicles on the road and getting people to and from their destinations while improving safety and
More information15,000 BTU Portable Air Conditioner
Instruction Manual 15,000 BTU Portable Air Conditioner Model: HYAC15 READ AND SAVE THESE INSTRUCTIONS Please read and follow the instructions in this user manual even if you feel you are familiar with
More informationA/C-Service Unit 7KG-MOBIL Art.-No
Art.-No. 0764 98 Instruction manual 1 WÜRTH reserves the right to discontinue, or change at any time specifications or designs without notice and without incurring obligations according to her policy of
More informationTHROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H
THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...
More informationHNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI
NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully
More informationRecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual
RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation
More informationAriazone 5001 HFO-1234yf
Automotive Air-Conditioning Service Equipment Ariazone 5001 HFO-1234yf OPERATOR MANUAL 1 Contents Page 1. Introduction... 3 2. Safety... 4 3. Technical Features... 5 4. Main Parts & Features... 6 5. Preparing
More informationOPERATION & MAINTENANCE MANUAL TC670
OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE
More informationDriven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf
Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC
AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationPortable Air-conditioner
Use and Care Manual Portable Air-conditioner Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED
More informationModel K / K. Modelo K / K. Modèle K / K. Operating Manual
Operating Manual Model 34800-2K / 34801-2K Recovery/Recycling/Recharging Unit for R-12 and R-134a Refrigerants... English Modelo 34800-2K / 34801-2K Unidad de recuperación/reciclaje/recarga para refrigerantes
More informationOperation Manual... 1 Manuel d utilisation Manual de Operación.. 60
Operation Manual... 1 Manuel d utilisation... 30 Manual de Operación.. 60 SERIES: ACR2000 KENT-MOORE: J-43600 Air Conditioning and Refrigerant Service Solution WARNING Refrigerant: R134a PRESSURIZED TANK
More informationKSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector
Issue 1 KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR Installation Manual Instructions for :- For safe and correct use please read the installation manuals supplied with the equipment.
More informationOperating Manual. Model K/ K Recovery/Recycling/Recharging Unit
Operating Manual Model -K/-K Recovery/Recycling/Recharging Unit Model -K (for R- refrigerant) Model -K (for R-a refrigerant) Recover, Recycle, and Recharge Unit SAFETY DEFINITIONS: Follow all WARNING,
More informationR410a Installation and fault finding training
R410a Installation and fault finding training Contents: General introduction Disassembly and reassembly Installation guide Trouble shooting General introduction: 1. Product Introduction Development Specification
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC
AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationOperation regulations must be strictly obeyed.
General This manual will help the user to operate this equipment safely and correctly. Correct operation of this air drier will reduce maintenance costs and extend the working life of all systems and parts
More informationMobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265
Mobile Air Conditioner Use and Care Manual Part Number: 048-GM-48265 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before
More informationWINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL
MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or
More informationRequests for Daily Care and Maintenance
Inkjet printer UJF-7151 plus Requests for Daily Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which
More informationPressure switch KPU. Data sheet
Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also
More informationINSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X
Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed
More informationAC 1 AIR CONDITIONING SYSTEM
AC1 AC2 GENERAL INFORMATION REFRIGERATION SYSTEM Prevention of Release and Excessive quantities (CFCs) for automobile air conditionings is be lieved to cause harm by depleting the ozone layer which helps
More informationAUTOMATIC TROLLEY UNIT FOR RECOVERY, RECYCLING, VACUUM AND CHARGE
AUTOMATIC TROLLEY UNIT FOR RECOVERY, RECYCLING, VACUUM AND CHARGE User s manual Sistemi e strumenti per condizionamento e refrigerazione Air conditioning and refrigeration systems and instruments Anlagen
More informationOPERATING MANUAL. Model 34134Z. Refrigerant Unit Recover, Recycle, and Recharge
OPERATING MANUAL Model 34134Z Refrigerant Unit Recover, Recycle, and Recharge Recover, Recycle, and Recharge Unit Model: 34134Z Refrigerant: R-134a Voltage: 115, 60 Hz LISTED 80S2 Recycling Equipment Design
More informationTLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL
TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL Contents 1. Introduction... 3 1.1 Features... 3 1.2 Specifications... 3 2. Installation... 3 3. Machine explosion drawing... 4 4. Equipment
More informationHEATING AND AIR CONDITIONING
WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT
More informationInstruction Manual. Model: EPA 16 Portable Airconditioner
Instruction Manual Model: EPA 16 Portable Airconditioner Distributed in Australia by: Honeyair Australia Pty Ltd. 78 Mallard Way, Cannington WA 6107 P 1300 710 860 F 1300 710 890 E info@gbi.com.au SPECIFICATIONS
More informationOriginal Instructions Instucciones originales Consignes originales. Model: AC R-1234yf A/C Recover, Recycle, Recharge Machine
Original Instructions Instucciones originales Consignes originales Model: AC1234-6 R-1234yf A/C Recover, Recycle, Recharge Machine Description: Recover, recycle, and recharge machine for use with R-1234yf
More informationINSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700
A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,
More informationDr. Infrared Heater Elite Series
Dr. Infrared Heater Elite Series 1500 Watts with Two Heat Settings Built-In Humidifier Rotatable Air Outlet Automatic Thermostat Tip-Over Switch Overheat Thermal Cut-Off Protection Room Temperature LED
More informationRoom Air Conditioner Service and Parts Manual
Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20
More informationAC1234 PRODUCT RANGE.
AC1234 PRODUCT RANGE THE REFERENCE POINT FOR THE MAINTENANCE OF THE R-1234YF A/C SYSTEMS www.ac1234yf.com AC1234-8, AC1234-7 AND AC1X34-7 AC1234-8 and AC1234-7 are service stations which perform maintenance
More information"World Class Quality" ULT/MA ID- HVAC REFRIGERANT IDENTIFIER OPERATION MANUAL
"World Class Quality" ULT/MA ID- HVAC REFRIGERANT IDENTIFIER OPERATION MANUAL Manual File ECO 8291 Revised: August 28, 2007 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431
More informationMacDonald Steel Limited
DELUXE FILLER / CROWNER MODEL - DFC4 1 REV 00 CAUTION / WARNING READ MANUAL BEFORE OPERATING MACHINE DO NOT EXCEED 50 PSI ON Co2 OR BEER LINES DO NOT EXCEED 100 F (35 C) ON Co2 OR BEER LINES DO NOT HOSE
More informationKOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS
KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS KOOLKARE DUAL GAS UNIT The air conditioning maintenance unit KoolKare Dual Gas
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for
More informationPortable Air-conditioner Use and Care Manual
Portable Air-conditioner Use and Care Manual Part Number: 048-GM-48266 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before
More informationHeater with Air Conditioning. E-Series Ford Aeromaster
Service Guide Heater with Air Conditioning E-Series Ford Aeromaster Contents Blower Motor...2 Plenum Removal...3 Control Module...6 Servo Motors...8 Coolant Valve and Servo Motor...8 Evaporator Recirculation
More informationOPERATION & MAINTENANCE MANUAL AC880
OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035-80749-00 TABLE OF CONTENTS AC880 Before Using the AC880... 2 Safety Precautions... 2 Using the AC880... 3 Setup... 4 Fill
More informationRequests for Care and Maintenance
Inkjet printer CJV300-30/60 Requests for Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which the ink
More informationAUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET
AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH
More informationOWNER S MANUAL (English)
TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance
More informationMODEL 7000 SUCTION UNIT
MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices
More informationEST User Manual. (Please read this manual carefully before using)
EST-1000 Handheld Intelligent Toxic Gas Detector User Manual (Please read this manual carefully before using) ENVIRONMENTAL SENSOR TECHNOLOGY CO.INC. Contents I. Product Overview...1 II. Product Description...1
More informationDigital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS
Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com
More informationVacuum system component SELVACS
Vacuum system component SELVACS Vacuum related components CC-796A 1 Wide variations for an assortment of applications New SELVACS vacuum components respond to a wide range of applications from fine work
More informationPRO 2000i LOW LEVEL DEPOSITOR
DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)
More informationPRE-INSTALLATION PROCEDURE
PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4
More informationPATENTED PATENT PENDING PATENTED PATENTED
2017 2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENT PENDING The first A/C system and passenger compartment air purification system combined with a charging station. 2 services in a single
More informationOPERATIONS MAINTENANCE MANUAL
OPERATIONS and MAINTENANCE MANUAL White 1090ST Refrigerant Recovery/Recycle/Recharge Unit Table of Contents Safety... 1 Introduction... 8 Refrigerant Gases... 8 Refrigerant Handling... 9 Refrigerant Safety...
More informationYC ON-OFF SERIES. Service Manual
YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant
More informationGENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.
Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER
More information