O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

Size: px
Start display at page:

Download "O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT"

Transcription

1 GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose lights are not available. SHIPPING WEIGHT --- Weight

2 ELECTRICAL DATA Fans Per High Effciency Fans 120 Volts Length Amps Watts 4' ' ' ' ' LIGHTING DATA Length Lights per row Lights Length Clearvoyant LED Lighting (Per Light Row) Standard Power (Cornice or Shelf) High Power (Cornice) 120 Volts 120 Volts Amps Watts Amps Watts 4' 1 4' ' 2 3' ' 2 4' ' 3 3'/4' ' 3 4' GUIDELINES AND CONTROL SETTINGS Front Sill BTUH/ft Superheat Set Evaporator Discharge Discharge Air Application Height Conventional Parallel Bulb ( F) ( F) Air ( F) Velocity (FPM) Dairy/Deli/Produce All Meat Extended DEFROST CONTROLS Timed-Off Defrost Defrosts Per Day Fail-Safe NOTES "---" indicates that the feature is not an option for this case model and/or the data is not yet available. Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft per row of lighted shelving. BTUH load increases by 132 BTUH/ft when aftermarket merchandising accessories are utilized. Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control Recommended Settings: Cut-In Temp = Discharge Air + 2 F; Cut-Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity immediately after defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature.

3 SECOND NATURE DATA BTUH/FT (DR) GPM/ft Supply Fluid Discharge Air Model Coils Application Front Sill Type Conventional Parallel (DR) 1 Bulk Produce Standard Deli/Produce Standard Meat 3" Extended Bulk Produce Standard Deli/Produce Standard Meat 3" Extended SECOND NATURE DATA Timed-Off Defrost Warm Fluid Defrost Model Coils Application Front Sill Type Defrost Fail Safe Fail Safe 1 Bulk Produce Standard Deli/Produce Standard Meat 3" Extended Bulk Produce Standard Deli/Produce Standard Meat 3" Extended

4 OPTIONS REAR SILL OPTIONS ORIGIN 2 FLAT FLAT TOP STANDARD REAR SILL 8 9/16" [21.7 cm] 12 1/2" REAR SILL 12 7/16" [31.7 cm] 16" REAR SILL (REAR DISCHARGE) 16 1/16" [40.7 cm] 27 1/16" [68.7 cm] 33 1/8" [84.2 cm] 32 15/16" [83.7 cm] 30" [76.2 cm] 28 1/8" [71.4 cm] 27 1/4" [69.3 cm] 27 1/8" [68.8 cm] 24 3/16" [61.4 cm] FLAT ANGLED TOP 22 5/16" [56.7 cm] 32 7/16" [82.3 cm] 30" [76.2 cm] 33" [83.8 cm] 33 1/8" [84.2 cm] 27 1/16" [68.7 cm] 27 1/4" [69.3 cm] 27 1/16" [68.8 cm] 24 1/8" [61.3 cm] 26 5/16" [66.9 cm] 27 1/16" [68.7 cm] 33 1/8" [84.1 cm] 32 15/16" [83.7 cm] 30" [76.2 cm] 33 7/16" [84.9 cm] 27 3/8" [69.5 cm] 33" [83.8 cm] 27" [68.6 cm] 27 1/4" [69.1 cm] 27 1/16" [68.8 cm] 24 1/8" [61.3 cm] NOTES: Front and rear sill heights vary with base frame height. Extended front sills are required for meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a 5" baseframe, or 30" on an 11" baseframe.

5 12 3/8" [31.4 cm] 33 3/4" [85.9 cm] THROAT DISPLAY 54" [137.2 cm] CASE HEIGHT 24 3/4" [62.9 cm] INTERIOR HEIGHT 12" 1 LOAD LIMIT 12" 1 18" 32 1/4" [81.9 cm] COIL PLENUM 48 1/8" [122.2 cm] CASE HEIGHT 24 3/4" [62.9 cm] INTERIOR HEIGHT 18" COIL PLENUM LOAD LIMIT 11" [27.9 cm] 29 7/8" [75.9 cm] 32 1/2" [82.6 cm] 43 1/4" [109.9 cm] 22 7/8" [58.1 cm] 27" [68.6 cm] 5 1/8" [13.0 cm] 3 7/8" [9.8 cm] 36 1/2" [92.8 cm] 17" [43.2 cm] 21 1/8" [53.6 cm] 11" BASE FRAME 5" BASE FRAME 2" MINIMUM AIR GAP 4" [10.2 cm] REAR REFRIGERATION LOCATED 14 1/2" ABOVE FINISH FLOOR 36 1/2" [92.7 cm] 5" BASEFRAME 32 1/2" [82.6 cm] 11" BASEFRAME 28 1/2" [72.4 cm]* 15 7/8" [40.3 cm]** 11" BASEFRAME 34 1/8" [86.7 cm]** 5" BASEFRAME 28 5/8" [72.7 cm] DEFAULT REFRIGERATION ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION 1 1/2" [3.8 cm] {END} 8 3/4" [22.2 cm] 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] NOTES * :STUB-UP AREA ** :RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS 1 :AVAILABLE SHELF SIZES: 10", 12", 14", 16", & 18" Ends add approximately 1" to case height, 1" to the front and 1/2" to the back.

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES "---" indicates that the feature is not an option with this case model and/or the data is not available at this time. SHIPPING WEIGHT --- Weight ELECTRICAL DATA Fans Per High Effciency Fans

More information

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES "---" indicates that the feature is not an option with this model and/or the data is not yet available. LED lights only. Maximum of 6 rows of standard output LED shelves. SHIPPING WEIGHT

More information

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES: GENERAL "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. 3rd row or

More information

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available at this time. LED lights only. Maximum of 4 rows of Standard Output LED lighted shelves.

More information

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available yet. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING

More information

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.

More information

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG --- GENERAL NOTES: "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. If the case is being lined up to an ORS5DM reach-in case, a 21" front

More information

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood) REFERENCE NOTES FOR ENGINEERING DATA: Extended front sills are required to meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a 5" baseframe, or

More information

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES ENGINEERING REFERENCE SHEET NOTES "0.00" indicates that the feature is not an option on this case model LED Lights Only Cornice lights are either standard or high output Shelf lights are standard output

More information

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA: REFERENCE NOTES FOR ENGINEERING DATA: "0.00" indicates that the feature is not an option on this case model LED Lights Only. Cornice lights are either standard or high output. Shelf Lights are standard

More information

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat) GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors

More information

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat) GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors

More information

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES GENERAL Light controls - occupancy sensors are required Option 1: OEM Provided: OEM anti-condensate and lighting controls (on/off) are standard unless otherwise specified. Option 2: End User Provided:

More information

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.

More information

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT DELI C A S E S MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK Featuring Technology COMPONENT P902077H Rev 4 1/07 WARNING MORE THAN ONE SOURCE OF ELECTRICAL SUPPLY. DISCONNECT

More information

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT REAR LOAD DAIRY C A S E S M O D E L : O 5 D R & O 5 D R H INSTALLATION & OPERATION HANDBOOK P056170D COMPONENT Rev. 13 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased you joined

More information

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT DELI C A S E S MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK COMPONENT P052392H Rev. 14 05/09 Welcome to the Hill PHOENIX display case family. We re very pleased you joined us. This installation

More information

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION HANDBOOK INSTALLATION & OPERATION O3EIF MEAT CASES Table of Contents General Information... 2 Using Casters... 3 Case Dimensions... 4 Case Operations... 5 Line Up & Trim Out... 6 Piping: Refrigeration

More information

OWIZ/OWIZV OWEZ/OWEZV

OWIZ/OWIZV OWEZ/OWEZV SINGLE-DECK ISLAND MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N U A L OWIZ/OWIZV OWEZ/OWEZV Table of Contents General Information... 2 Airflow & Defrost... 7 Case Installation...3-4 Cleaning

More information

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT DELI C A S E S MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK COMPONENT P05971K Rev. 8 7/04 Welcome to the ORIGIN display case family. We re very pleased you joined us. This installation

More information

RM with INNOVATOR Doors

RM with INNOVATOR Doors RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in

More information

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT 3-DECK ISLAND PRODUCE C A S E S M O D E L S : O 3 I P & O 3 I P B INSTALLATION & OPERATION HANDBOOK COMPONENT P053096D Rev. 9 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased

More information

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount Freedom Line RFM with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready OPTIONS SHOWN: Lighted Facades I A H C J B F NSF Certified October 18 G Warning: Terminal block NOT for

More information

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11 R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORZ ORZH ONRZ (ALSO INCLUDES ONRZH) General Information... 2 Case Installation... 3 5 Case Connections...

More information

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case

More information

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item # FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat 2.43 3.43 4.35 5.40 PSC Fan 0.52 0.78 1.04 1.30 STD Fan 1.04 1.56 2.08 2.60 ECM Fan 0.50 0.75 1.00 1.25 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED

More information

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for

More information

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A

More information

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item # G C A F-L Technical Data Sheet P/N 0523702_C NSF Certified March 2017 H B E F J We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL O5Z Table of Contents Electrical Data & Case Dimensions... 2 3 General Information... 4 Imporant Notices... 5 Line-Up... 6 7 Trim Out....

More information

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item # FG-L Technical Data Sheet P/N 0523821_C A NSF Certified March 2017 G H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

RL with INNOVATOR II No Heat Doors

RL with INNOVATOR II No Heat Doors RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding

More information

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item # Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT ISLAND PRODUCE C A S E S MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK COMPONENT P054956H Rev. 7 11/06 Welcome to the ORIGIN 2 display case family. We re very pleased you joined us. This

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N H C J A F E FIG Technical Data Sheet NSF Certified March 2017 G B I We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

RLT with INNOVATOR Doors

RLT with INNOVATOR Doors Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve

More information

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National

More information

Nosing Heater. Return Grill Heater

Nosing Heater. Return Grill Heater Insight standard field electrical connections are at the bottom of the merchandiser Insight IM1SL-L Merchandiser Data Sheet NSF Certifi ed September 2017 Fan* Defrost Heater (Below coil)* Coil* Nosing

More information

P/N _F NSF Certified June 2010

P/N _F NSF Certified June 2010 G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such

More information

FG-L Technical Data Sheet

FG-L Technical Data Sheet FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection

More information

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item # FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

Engineering Plan Views

Engineering Plan Views LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case

More information

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item # G FWEL Technical Data Sheet NSF Certified January 2018 E D C H B A F J We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

PWEE Technical Data Sheet

PWEE Technical Data Sheet Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)

More information

QDV5V - 1 Door Standard (Gemtron)

QDV5V - 1 Door Standard (Gemtron) CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.51 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 All electrical data based on 115V and

More information

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount. Freedom Line RFMNS with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready H B F P/N 054156_J NSF Certified January 01 C I We reserve the right to change or revise specifications

More information

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX... R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORIZ ORIZH ONRIZ (ALSO INCLUDES ONRIZH) TABLE OF CONTENTS GENERAL INFORMATION... 2 INSTALLATION &

More information

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG. E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any

More information

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &

More information

RLNIE with INNOVATOR II

RLNIE with INNOVATOR II Warning: Terminal block NOT for case-to-case wire connection! RLNIE with INNOVATOR II No Heat Doors NSF Certified April 2017 We reserve the right to change or revise specifications and product design in

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to

More information

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018 RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our

More information

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018 RLTIM with INNOVATOR We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes,

More information

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish FWG-L Technical Data Sheet P/N 0523827_D NSF Certified May 2016 DOE 20 Energy Efficiency Compliant We reserve the right to change or revise specifications and product design in connection with any feature

More information

Case Study of Adding Glass Doors to Multi-Deck Meat Case

Case Study of Adding Glass Doors to Multi-Deck Meat Case Case Study of Adding Glass Doors to Multi-Deck Meat Case Project Summary Two 8 multi-deck meat cases were installed and refrigerated in the Hillphoenix case laboratory. After confirming identical operating

More information

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016 Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the

More information

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost. bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features

More information

RMN with INNOVATOR Doors Technical Data Sheet

RMN with INNOVATOR Doors Technical Data Sheet Merchandisers RMN with INNOVATOR Doors Technical Data Sheet P/N 0435491_J NSF Certified November 2009 G E F D A Warning: Terminal block NOT for case-to-case wire connection! C B We reserve the right to

More information

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13 DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK P056442G Rev. 13 12/13 DANGER Electrical Shock Hazard Always disconnect power to case when servicing or cleaning. WARNING disconnect

More information

IMPORTANT KEEP IN STORE FOR FUTURE USE

IMPORTANT KEEP IN STORE FOR FUTURE USE Part Number: 31E11030 Date: 8/24/2011 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 Installation & Operation Manual QM2T(E) QM3T(E) Wide Island Multi-Deck Display Case IMPORTANT KEEP IN STORE

More information

QC BEVERAGE/DAIRY/DELI

QC BEVERAGE/DAIRY/DELI MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L QC BEVERAGE/DAIRY/DELI Table of Contents Energy Data & Case Dimensions...2-5 Pre-Power Checklist...13 General Information...

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display

More information

Low Flow Unit Coolers

Low Flow Unit Coolers BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3

More information

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2042 January 2015 Part No. 31E02042 Contents STRATUS Multi- Deck Display Case Introduction General Information

More information

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases Installation & Service Manual THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation & Service

More information

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item # LNG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017 Shown with Optional Light Bar Technical Data Sheet NSF Certified March 2017 Condensing Unit Control Panel We reserve the right to change or revise specifications and product design in connection with any

More information

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2098 March 2013 Part No. 31E02098 Contents STRATUS Multi- Deck Display Introduction General Information 2 Plan

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General

More information

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item # LG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.

More information

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2040 March 2013 Part No. 31E02040 Contents STRATUS Multi- Deck Display Case Introduction General Information

More information

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L CDC-R & CDC-D BAKERY Table of Contents Energy Data & Case Dimensions...2-5 Pre-Power Checklist...13 General Information...

More information

MODEL RD-8 Self Contained MODEL RD-2

MODEL RD-8 Self Contained MODEL RD-2 MODEL RD-8 Self Contained REFRIGERATED SHOWCASE MODEL RD-2 REFRIGERATED SHOWCASE Document Part #: 1150285 Rev: I ECN: 55118 Rev. Date: 5-28-14 The RD-2 and RD-8 refrigerated display showcase units have

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL Part No. 31E11044 Date: 4/11/11 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QFGCEID-A, QFGTD-A QNGCEID-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR

More information

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2030 January 2015 Part No. 31E02030 Contents STRATUS Multi- Deck Display Case Introduction General Information

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2031 January 2015 Part No. 31E02031 Contents STRATUS Multi- Deck Display Case Introduction General Information

More information

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE Part No. 31E10015 Date: 3/2/10 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT

More information

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L S2SGC MEAT/SEAFOOD Table of Contents Energy Data & Case Dimensions...2-3 Pre-Power Checklist...17 General Information... 4

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual N7DNHPL, NHDHPL, NHDHPM HIGH PERFORMANCE EXT. HEIGHT MULTI-SHELF MERCHANDISER Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction

More information

Unico Training. Welcome to Unico!

Unico Training. Welcome to Unico! Welcome to Unico! UNICO Inc Who are we? Unico Inc. is a family owned and operated manufacturing company. Unico Inc. is the largest manufacturer of SDHV systems in the world. Unico Inc. is manufactured

More information

HVI-4-406R/HVI-4-408R

HVI-4-406R/HVI-4-408R MULTI-DECK MERCHANDISER INSTALLATION & OPERATIONS MANUAL HVI-4-406R/HVI-4-408R BEVERAGE/DAIRY/DELI Table of Contents Energy Data & Case Dimensions...2-7 General Information... 8 Installation...9-10 Case

More information

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15 Part No. 31E11043 Date: 1/5/15 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

NFW, NCW, NFWG, NCWG, NFWE, NCWE

NFW, NCW, NFWG, NCWG, NFWE, NCWE Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)

More information

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc. INTRODUCTION SERVICING SUPERMARKET REFRIGERATION EQUIPMENT The 1960s and early 1970s brought about a revolution in the merchandising of food products. With the growth and extension of suburban areas has

More information

Unico Training. Class for R E Michel Salesmen

Unico Training. Class for R E Michel Salesmen Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,

More information

Technical Manual Binair Monobloc Heat Pump

Technical Manual Binair Monobloc Heat Pump Technical Manual Binair Monobloc Heat Pump MODEL BINAIR12 Introduction Disassembly of the machine must be carried out by any professional or any special agency assigned by us. All operation and maintenance

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Single Door cooler series MODEL NOS. CS32SB CS32SG CS32SS CS32ST IMPORTANT INFORMATION To register your product, visit our web site at (www.perlick.com). Click on

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-529 REV. 6 Supersedes Form No. H11-529 Rev. 5 Featuring Industry Standard R-410A Refrigerant RHGL- 090, 120, 180 & 240 SERIES NOMINAL SIZES 7.5, 10, & 20 TONS [26, 35,

More information