QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR
|
|
- Ferdinand Poole
- 5 years ago
- Views:
Transcription
1 CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat PSC Fan STD Fan ECM Fan Light (T8 ELS) LED Light (Gelcore) Drain Pan Heater Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Eliminator - QIV5V-A - Glass Door Eliminator - Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² ft³ 5 60 ft² ft³ Air Velocity Air -17 F 300 FPM -11 F -10 F 300 FPM -5 F units. ADD 8% to BTU LOAD. The above case model has case lengths that are UL and NSF approved. (-17 F) STD Fan 1286 PSC Fan 1238 ECM Fan 1180 (-10 F) STD Fan 1200 PSC Fan 1153 ECM Fan 1095
2 CASE DATA - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps PSC Fan Amps STD Fan Amps ECM Fan Amps LED Light Amps (Gelcore) T8 Lights Drain Heater Amps Defrost Load Amps (optional 230V) All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Electric 1 45 min 65 F Hot Gas 1 25 min 47 F Assorted Shelving Options Available QLV5VT-A - Tall Glass Door - Standard ( ) QIV5VT-A - Tall Glass Door - Standard ( ) Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. STD Fan PSC Fan ECM Fan units, add 8% to BTU load. *For lighted shelves, please add 19 BTUH.* Add 30 BTUH/Door for STD motors. The above case model has case lengths that are UL and NSF approved. Door Facing Area (ft²) Cubic Capacity (ft³) Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F Issue:
3 CASE DATA - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps PSC Fan Amps STD Fan Amps ECM Fan Amps LED Light Amps (Gelcore) T8 Lights Drain Heater Amps Defrost Load Amps (optional 230V) All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Electric 1 45 min 65 F Hot Gas 1 25 min 47 F Assorted Shelving Options Available QLV5VT-A - Tall Glass Door - Eliminator ( ) QIV5VT-A - Tall Glass Door - Eliminator ( ) Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. STD Fan PSC Fan ECM Fan units, add 8% to BTU load. *For lighted shelves, please add 19 BTUH.* Add 30 BTUH/ Door for STD motors. The above case model has case lengths that are UL and NSF approved. Door Facing Area (ft²) Cubic Capacity (ft³) Air Velocity Air -17 F 300 FPM -12 F -10 F 300 FPM -5 F Issue:
4 CASE DATA AMPS 1 Door Anti-Sweat 1.90 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.24 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel /2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION /32 4 1/2? REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door Standard - (Anthony) QIV5V - 1 Door Standard - (Anthony) that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -11 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1424 ECM Fan 1346 (-11 F) PSC Fan 1348 ECM Fan 1270
5 CASE DATA AMPS 1 Door Anti-Sweat 1.79 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel /2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION ? 29 17/32 4 1/2 REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door - (Gemtron) QIV5V - 1 Door - (Gemtron) that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -11 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1424 ECM Fan 1346 (-11 F) PSC Fan 1348 ECM Fan 1270
6 CASE DATA AMPS 1 Door Anti-Sweat 1.35 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.24 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel /2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION /32 4 1/2? REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door Eliminator - (Anthony) QIV5V - 1 Door Eliminator - (Anthony) Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -10 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1284 ECM Fan 1206 (-11 F) PSC Fan 1208 ECM Fan 1130
7 CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat PSC Fan STD Fan ECM Fan Light (T8 ELS) LED Light (Gelcore) Drain Pan Heater Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Standard - (Anthony) QIV5V-A - Glass Door Standard - (Anthony) Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² ft³ 5 60 ft² ft³ Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F units. ADD 8% to BTU LOAD. (-18 F) STD Fan 1426 PSC Fan 1378 ECM Fan 1320 (-11 F) STD Fan 1325 PSC Fan 1278 ECM Fan 1220 The above case model has case lengths that are UL and NSF approved.
8 CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat PSC Fan STD Fan ECM Fan Light (T8 ELS) LED Light (Gelcore) Drain Pan Heater Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Gemtron - QIV5V-A - Glass Door Gemtron - Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft ft² 91.0 ft ft² ft ft² ft 3 Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F units. ADD 8% to BTU LOAD. The above case model has case lengths that are UL and NSF approved. (-18 F) STD Fan 1426 PSC Fan 1378 ECM Fan 1320 (-11 F) STD Fan 1325 PSC Fan 1278 ECM Fan 1220
QDV5V - 1 Door Standard (Gemtron)
CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.51 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 All electrical data based on 115V and
More informationINSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE
Part No. 31E10015 Date: 3/2/10 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT
More informationINSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15
Part No. 31E11043 Date: 1/5/15 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE
More informationO5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---
GENERAL NOTES: "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. If the case is being lined up to an ORS5DM reach-in case, a 21" front
More informationON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:
GENERAL "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. 3rd row or
More information6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA
REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.
More informationO2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)
REFERENCE NOTES FOR ENGINEERING DATA: Extended front sills are required to meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a 5" baseframe, or
More informationOHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available at this time. LED lights only. Maximum of 4 rows of Standard Output LED lighted shelves.
More information6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this model and/or the data is not yet available. LED lights only. Maximum of 6 rows of standard output LED shelves. SHIPPING WEIGHT
More informationON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this case model and/or the data is not available at this time. SHIPPING WEIGHT --- Weight ELECTRICAL DATA Fans Per High Effciency Fans
More informationORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)
GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors
More informationINSTALLATION & OPERATION MANUAL
Part No. 31E11044 Date: 4/11/11 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QFGCEID-A, QFGTD-A QNGCEID-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR
More informationO3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose
More informationO4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES
ENGINEERING REFERENCE SHEET NOTES "0.00" indicates that the feature is not an option on this case model LED Lights Only Cornice lights are either standard or high output Shelf lights are standard output
More informationO5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.
More informationVNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES
GENERAL Light controls - occupancy sensors are required Option 1: OEM Provided: OEM anti-condensate and lighting controls (on/off) are standard unless otherwise specified. Option 2: End User Provided:
More informationO5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available yet. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING
More informationOIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:
REFERENCE NOTES FOR ENGINEERING DATA: "0.00" indicates that the feature is not an option on this case model LED Lights Only. Cornice lights are either standard or high output. Shelf Lights are standard
More informationONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)
GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors
More informationIMPORTANT KEEP IN STORE FOR FUTURE USE
Part Number: 31E11030 Date: 8/24/2011 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 Installation & Operation Manual QM2T(E) QM3T(E) Wide Island Multi-Deck Display Case IMPORTANT KEEP IN STORE
More informationQM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007
Part Number: 31E03028 Date: 08/13/2007 5201 Transport Boulevard Columbus, GA. 31907 706-568-1514 Installation & Operation Manual QM5, QM5G Multi-Deck Meat Display Case IMPORTANT KEEP IN STORE FOR FUTURE
More informationInstallation & Operation Manual
Part Number: 31E11040 Date Revised: 11/14/2011 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 Installation & Operation Manual QWM1GD Single Deck Display Case IMPORTANT KEEP IN STORE FOR FUTURE
More informationProduct Specifications Sheets
Product Specifications Sheets GF Series - Hinged Glass Doors Bottom Mount - 78.5"H Power Est. Ship Model No. Description Length Depth Height Voltage Amps HP/BTUs Cord Weight Freezers / Frozen Food GF19BM-FF
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationP/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet
Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationEXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet
EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More informationP/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet
Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)
More informationLow Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.
LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of
More informationEXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet
EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationBEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017
Shown with Optional Light Bar Technical Data Sheet NSF Certified March 2017 Condensing Unit Control Panel We reserve the right to change or revise specifications and product design in connection with any
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2075 March 2013 Part No. 31E02075 Contents STRATUS Multi- Deck Display Case Introduction General Information
More informationExcel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet
Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationNFW, NCW, NFWG, NCWG, NFWE, NCWE
Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING
DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S
More informationORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11
R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORZ ORZH ONRZ (ALSO INCLUDES ONRZH) General Information... 2 Case Installation... 3 5 Case Connections...
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationRMN with INNOVATOR Doors Technical Data Sheet
Merchandisers RMN with INNOVATOR Doors Technical Data Sheet P/N 0435491_J NSF Certified November 2009 G E F D A Warning: Terminal block NOT for case-to-case wire connection! C B We reserve the right to
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationInstallation and Operation Manual
series Installation and Operation Manual FGCEID GLASS DOOR REACH-IN This refrigerator conforms to the Commercial Refrigerator Manufacturers Association s Health and Sanitation Standard. series Page 2 INSTALLATION
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2098 March 2013 Part No. 31E02098 Contents STRATUS Multi- Deck Display Introduction General Information 2 Plan
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationIntroductions General Information. Receiving/Shipping Damage/Lost Items
Page 2 Table of Contents Introductions General Information... 4 Case Description... 4 Receiving/Shipping Damage/Lost Items... 4 Refrigerant... 5 Condensing Unit... 5 Condensate Evaporator Pan Heater:.
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2042 January 2015 Part No. 31E02042 Contents STRATUS Multi- Deck Display Case Introduction General Information
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2040 March 2013 Part No. 31E02040 Contents STRATUS Multi- Deck Display Case Introduction General Information
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationJUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases
Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction
More informationIntroductions General Information. Receiving/Shipping Damage/Lost Items
Page 2 Table of Contents Introductions General Information... 4 Case Description... 4 Receiving/Shipping Damage/Lost Items... 4 Refrigerant... 5 Condensing Unit... 5 Plan View and Cross Section... 6 Case
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2030 January 2015 Part No. 31E02030 Contents STRATUS Multi- Deck Display Case Introduction General Information
More informationInstallation & Operation Manual. Reach-In Display Case. KW-IOM-2149 July 2016 Part No. 31E02149
Installation & Operation Manual KW-IOM-2149 July 2016 Part No. 31E02149 Contents Reach-In Display Case Introduction General Information 3 Plan and Cross Views 5 Case Data 7 Case Installation 18 Electrical
More informationInstallation & Service Manual
Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General
More informationTECHNICAL SPECIFICATIONS B6VMMX
TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationRVZC30 (and BB/T/TBB/WA), RVZP30 (and BB/T/TBB/WA), RVC24
2 TABLE OF CONTENTS INTRODUCTION... 4 DELIVERY INSPECTION... 4 PACKAGING... 4 LOCATION... 4 Figure 1: Case label information... 5 INSTALLATION... 6 Leveling... 6 Figure 2: Leveling cases prior to joining...
More informationReach In Refrigerators Bottom Mount
Reach In Refrigerators Bottom Mount Product Specification Sheets Construction Standard Features Stainless Steel Doors Heavy duty hinge with self closing mechanism Exterior galvanized pre-painted steel
More informationInstallation & Operation Manual
5201 Transport Boulevard Columbus, GA. 31907 706-568-1514 Installation & Operation Manual QFGCEIX/Low Temperature Reach-In Display Cases with modular condensing unit IMPORTANT KEEP IN STORE FOR FUTURE
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationUnit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD
RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)
More informationInstallation & Service Manual
Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to
More informationInstallation & Service Manual
Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationL6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases
Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &
More informationAP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat
AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat Electric (Modular) Heat Option 4.75 Kw, 7.5 kw, 9.5 kw, 14.25
More informationGlass Doors, Hinged Bottom Mounts
Product Specification Sheets Construction Standard Features Interior and exterior constructed of heavyduty white coated steel CFC free foamed-in-place polyurethane insulation Stainless steel floor Externally
More informationORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...
R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORIZ ORIZH ONRIZ (ALSO INCLUDES ONRIZH) TABLE OF CONTENTS GENERAL INFORMATION... 2 INSTALLATION &
More informationslm series Refrigerant: R404a Refrigeration Range: -0 /-13 F Climate Range: +77 F/+95 F Forced Air Ventilation Automatic Hot Gas Defrosting
display options G.S. Gelato is excited about the opportunity to present authentic, artisan Gelato and Sorbet to your store! We are absolutely sure, since we have tested it for more than twenty years, that
More informationPPL Electric Utilities Energy Efficiency and Conservation Program
Installation of High-Efficiency High Efficiency Evaporator Fans Evaporator Fans That have Highfor Walk-ins Efficiency Permanent Split $50/fan motor Capacitor (PSC) Motor or ECM High Efficiency Compressors
More informationR21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities
R21C Packaged Terminal Air Conditioner (PTAC) The Right Fit for Comfort Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 Model R21C Specifications and Performance
More informationWH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3
FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides
More informationLow Flow Unit Coolers
BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3
More informationR22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort
R22C/H Packaged Terminal Air Conditioner (PTAC) Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 The Right Fit for Comfort kw 2.6 3.5 4.4 5.3 Model R22C Packaged Terminal Heat Pump (PTHP)
More informationSpecifications and Performance
R45C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh The Right Fit for Comfort 2.6 3.5 4.4 5.3 kw Heat
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationINSTALLATION & OPERATION MANUAL
series K//W Part #:31E03-027 Date: 9-00 Supersedes: INSTALLATION & OPERATION MANUAL M4N3 Multi-Deck, Narrow, Meat Merchandiser This case conforms to the Commercial Refrigerator Manufacturers Association
More informationJr. Tech (JT-1, 2, 3) Knowledge Areas
Jr. Tech (JT-1, 2, 3) Knowledge Areas The Jr. Tech Level includes technicians that are just entering the business and are in the beginning stages of their HVAC-R training and development. Over this period
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile
More informationInstallation & Operation Manual. Reach-In Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2149 January 2016 Part No. 31E02149 Contents Reach-In Display Case Introduction General Information 3 Plan and
More informationInstallation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual
Installation & Stratus Multi Deck Installation and Operations Operation Manual Manual KW-IOM-2031 January 2015 Part No. 31E02031 Contents STRATUS Multi- Deck Display Case Introduction General Information
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationBEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010
Shown with Optional Light Bar Q C B P Technical Data Sheet P/N 058280_A NSF Certified November 200 A Condensing Unit J Control Panel Item Part # Description Wiring Item # H F I We reserve the right to
More informationRLT with INNOVATOR Doors
Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve
More informationAIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:
AIR CONDITIONERS SPLIT TROPICAL RANGE FLAT SPLIT Heat & Cool R410a AMD 014 24K BTU EAN: 800 47 95666 9 AMD 01 18K BTU EAN: 80047956652 AMD 012 12K BTU EAN: 800 47 95664 5 AMD 014 Indoor U. Outdoor Dimensions
More informationPage ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018
` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with
More informationRheem Air Handlers. RHML- Series X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationCabinet & Merchandiser Price List
Cabinet & Merchandiser Price List Effective January 1, 2018 2018 Master-Bilt Products, an unincorporated division of Standex International Corporation. All rights reserved. Contents Section Page Ice Cream
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationDirect Install Program Eligible Measures Listing:
Direct Install Program Eligible Measures Listing: a) Lighting: - DLC qualified LED Luminaires including LED linear tube replacements - Energy Star Approved LED Screw In Lamps - T8 fixture replacements
More informationHANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION
HANDBOOK INSTALLATION & OPERATION O3EIF MEAT CASES Table of Contents General Information... 2 Using Casters... 3 Case Dimensions... 4 Case Operations... 5 Line Up & Trim Out... 6 Piping: Refrigeration
More informationReach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June
LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3
More informationM1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #
Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS 23 SEER Residential System Indoor Section M1200 Product Line PAH2VM Series Variable Speed Air Handler C5 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED
More informationKRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING
KRYO FORTRESS MOTOR/FAN PACKS A HIGH- ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING motor BUILT TO PROTECT The KRYO FORTRESS motor is an energy-efficient, unit bearing style ECM motor built to withstand
More informationWLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)
WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw
More informationVersatile new products for multiple applications and specialty conditions. New Products Catalog
Versatile new products for multiple applications and specialty conditions New Products Catalog LARGE CAPACITY STAINLESS STEEL BUILT-IN UNDER COUNTER Perfect for laboratories, satellite pharmacies, nursing
More informationAllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax
AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The
More information