Heating controller Lago
|
|
- Ruby Russell
- 5 years ago
- Views:
Transcription
1 Heating controller Lago Product brochure GB 10 Edition Wall-mounted (Lago Basic 0101/1001 and Lago 0321) Boiler or control panel attachment (Lago 0201R) Simple operation and programming Automatic sensor recognition LCD display to show temperatures, operating conditions and parameters For weather- and room temperature-dependent control, or fixed value control of the flow temperature Demand-related pump control CAN bus for system extension and system integration Various room control module connection facilities Choice of sensor 1 kω PTC or 5 kω NTC
2 2 Lago Edition Boiler controller with direct heating circuit and hot-water function Lago Basic 0101/1001 Boiler module / Mixer module Basic function Control of a fixed flow temperature or a fixed return temperature by controlling a heat generator or mixer. A room thermostat or timer (24 V) can be connected. Hot-water function via sensor or thermostat. Weather- and room temperature-dependent flow temperature control by controlling a heat generator or mixer (time-dependent control available with add-on module). Heating module in a cascade. Performance features Safety temperature limiter test Cooling operating mode (1001 in conjunction with mixer operation) Start-up relief Frost protection function Charging pump relief Circulation pump control (not with fixed value control) Pump blocking protection Mixer blocking protection Delayed pump switch-off Choice of sensor (5 kω NTC <-> 1 kω PTC) The Lago Basic is a basic module, which is suitable for the most diverse applications and is expansible for a more specific application. This controller is suitable for wall mounting. The electrical connection of the controller and the control components is possible via screw terminal blocks in the base. The controller features a demand-related pump circuit for every heating circuit. When connected to an outdoor sensor, the controller calculates a boiler or flow temperature based on the outside temperature, which can then be supplemented by a room control module with time control (see accessories). Control of a fixed flow temperature or a fixed return temperature by controlling a heat generator or mixer is achievable with the Lago Basic. The Lago Basic can also act as part of a cascade control. Here it is feasible to use it as a boiler or heating circuit controller. Display mode In the normal mode Run, the flow temperature of the heat generator or heating circuit is displayed. The following temperatures are given: 1. Outside temperature 2. Hot-water temperature 3. Room temperature Information about outputs Burner ON / Mixer OPENS Feed pump ON / Mixer CLOSES Heat generator pump ON / Heating circuit pump ON Bus communication OK
3 Lago Edition Boiler controller in cascade mode Boiler controller with header pump / mixer extension
4 4 Lago Edition Lago 0321 Basic function The unit includes the control for a one-stage heat generator, a process water generator and for a maximum of two heating circuits (one with mixer). Saving functions (demand-related circulation pump control) are also integrated. Alternatively, the pump relay of the direct heating circuit can also be used for the following functions: Circulation pump Return temperature increase Header pump If no heat generator sensor is connected, the unit can be used as a mixer extension. When a heat generator sensor is connected and an address is set (bus ID), the heat generator can be used in a cascade. It is then activated by a system controller. Performance features Safety temperature limiter test Auxiliary relay Choice of sensor (5 kω NTC <-> 1 kω PTC) Choice of controller operating mode Heating program [F1, F2] Heating curve Room sensor influence Outside temperature frost protection Maximum heat generator temperature Minimum heat generator temperature Start-up relief Minimum limit Charging pump relief Parallel pump operation Anti-legionnaire s disease function Maximum flow temperature Minimum flow temperature Mixer dynamic OPEN / CLOSE Multi-functional relay Relay test Display mode In the normal mode Run, the flow temperature of the heat generator or heating circuit is displayed. The following temperatures are given: 1. Outside temperature 2. Hot-water temperature 3. Room temperature Information about outputs Burner ON / Mixer OPENS Feed pump ON / Mixer CLOSES Heat generator pump ON / Heating circuit pump ON Bus communication OK
5 Lago Edition Boiler controller with a direct and a mixed heating circuit, and hot-water function Boiler controller with mixed heating circuit, hot-water function and return temperature increase Boiler controller with circulation pump, mixed heating circuit and hot-water function
6 6 Lago Edition Lago 0201R Heating module Basic function Heating module in a cascade with up to 8 heat generators Control of return temperature increase by pump or by mixer (depending on the configuration) Boiler or control panel attachment Rast 5 connection system Operation in a cascade A one-stage heat generator with appropriate boiler pump and return temperature increase via a pump or a mixer A two-stage heat generator with appropriate boiler pump and return temperature increase via a pump or a mixer Two one-stage heat generators with appropriate boiler pump and common return temperature increase via a pump A modulating heat generator with appropriate boiler pump Performance features Safety temperature limiter test Frost protection function (flow sensor frost protection, outdoor sensor frost protection) Temperature monitor function Return temperature increase via pump Return temperature increase via mixer Pump blocking protection Mixer blocking protection Delayed pump switch-off Choice of sensor (5 kω NTC <-> 1 kω PTC)
7 Lago Edition Legend A Heat generator with temperature sensor KF and connecting input T1, T2 B Heat generator pump (in the flow circuit if required) C Return sensor VF D Return temperature increase via mixer E Return temperature increase via pump Heat generator controller in cascade mode
8 8 Lago Edition Technical data Supply voltage pursuant to DIN IEC 60038: 230 V AC ± 10% Power consumption: max. 5 VA Switching capacity of the relays: 250 V, 2(2) A Max. current on terminal L1: 6.3 A Enclosure pursuant to DIN EN 60529: IP 40 Safety class pursuant to DIN EN 60730: II, totally insulated Power reserve of the timer: >10 hours Permitted ambient temperature in operation: 0 50 C Storage temperature: C Sensor resistance: NTC 5 kω (AF, KF/SPF, VF) Tolerance in Ohm: +/- 1% at 25 C Temperature tolerance: +/- 0.2K at 25 C Sensor resistance: PTC 1010 Ω, (AFS, KFS/ SPFS, VFAS) Tolerance in Ohm: +/- 1% at 25 C Temperature tolerance: +/- 0.3K at 25 C Dimensions (HxWxD): Wall-mounted base for Lago Basic 0101/1001 and Lago 0321: 96x144x67 mm Installation dimensions for Lago 0201R: 96x144x63 mm Accessories A room thermostat or timer (24 V) can be connected. If a room thermostat is connected, the flow temperature can be controlled dependent on the outside temperature, room temperature or time by controlling a heat generator or mixer. Merlin BM Digital operation-control module with CAN bus interface BM8 Digital operation-control module with CAN bus interface Lago FB Digital remote control with CAN bus interface FBR 1 / 2 Remote control with room sensor Lago FB switch Room thermostat (0 24 V switching voltage) Lago FB analogue switch Room thermostat (0 24 V switching voltage) Detailed information on this product Contact Sales Elster GmbH Postfach Osnabrück Strotheweg Lotte (Büren) Germany T F info@kromschroeder.com We reserve the right to make technical modifications in the interests of progress. Copyright 2013 Elster GmbH All rights reserved.
Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers
Boiler module and operator-control unit with for heating boilers Product brochure GB 10.5.2.2 Edition 02.04 odulating burner control unit with integral or external ignition Diverse possible applications
More informationBurner control unit BCU 370
Burner control unit BCU 370 Product brochure GB 6 Edition 11.08 For modulating, forced draught burners for gas of unlimited capacity in intermittent or continuous operation Control of fan and butterfly
More informationBurner control unit BCU 370
Burner control unit BCU 370 Product brochure GB 6.1.3.2 Edition 12.05 For modulating, forced draught burners for gas of unlimited capacity in intermittent or continuous operation Control of fan and butterfly
More informationSystem controller for cascade control, heating boilers with solar, buffer and pel et control
E8.5064 System controller for cascade control, heating boilers with solar, buffer and pellet control Modulating cascade controller with solar control Switching cascade controller with solar control Modulating
More informationControl valve S11T. Pilot burner ZT. Control valve S11T
Control valve S11T Pilot burner Product brochure GB 9.1 Edition 05.09 Control valve S11T Independent of mains power supply due to thermo-electric safeguarding Installation facilitated by pilot gas connection
More informationBurner control unit PFU 780
Burner control unit FU 780 roduct brochure GB 6 Edition 0. AGA For pilot and main burners of unlimited capacity in thermoprocessing equipment pursuant to EN 746- lug-in function unit for mounting in 9
More informationBurner control units BCU 480
Burner control units roduct brochure GB...8 Edition 0.07 For pilot and main burners of unlimited capacity in intermittent or continuous operation pursuant to EN 74- Automatic burner control unit, ignition
More informationBurner control units BCU 480
Burner control units BCU 480 roduct brochure GB 6 Edition. For pilot and main burners in intermittent or continuous operation Replace the local control cabinet Flame control by UV, ionization or a further
More informationE V1. System Manager Installation Manual
E8.5064 V1 System Manager Installation Manual Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information General information General
More informationProtective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.
Industrial & Commercial Thermal Protective system controls, automatic burner control units, burner control units Product brochure GB 6 Edition 06.15l FCU 500 Protective system controls FCU 500 Protective
More informationEnergy management with a system. Edition GB. Control engineering and combustion technology for comfortable heating
Energy management with a system Edition 10.12 GB Control engineering and combustion technology for comfortable heating 2 Energy management with a system Edition 10.12 Here is where the sparks fly! In the
More informationBurner control units BCU 460, BCU 465
Burner control units BCU 40, BCU 4 roduct brochure GB Edition 07.12 Replaces the local control cabinet For burners in intermittent operation or in continuous operation Flame control by UV, ionization or
More informationBurner control units BCU 560, 565
Burner control units BCU 560, 565 roduct brochure GB 6 Edition 05.15 For monitoring and controlling modulating or staged burners for multiple burner applications with a central air supply For directly
More informationIndustrial & Commercial Thermal BCU 580
Industrial & Commercial Thermal BCU 580 Burner control units For monitoring and controlling modulating or staged burners for multiple burner applications with a central air supply For directly ignited
More informationBurner control units BCU 560, 565
Burner control units BCU 560, 565 roduct brochure GB 6 Edition 07.15 For monitoring and controlling modulating or staged burners for multiple burner applications with a central air supply For directly
More informationSafety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.
Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these
More informationInstallation and Operating Manual. Merlin 5064 V3. System Manager
Installation and Operating Manual Merlin 5064 V3 System Manager Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information General
More informationSD2. Differential Controller. Operating and Installation Instructions F2 72.3
SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety
More informationSafety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place
8.. Edition 08.0 D GB F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions UV sensor UVS 0 Translation from the German 008 009 Elster GmbH Contents UV sensor UVS 0......................
More informationE System Manager Operating instructions
E8.4401 System Manager Operating instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information General information General
More informationInstallation and Operating Manual. Merlin IO 5064 V4 with BM-T. System Manager
Installation and Operating Manual Merlin IO 5064 V4 with BM-T System Manager Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information
More informationSafety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place
06 Elster GmbH Edition 0.6 Translation from the German 0556 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions UV sensor UVS 5 Cert. version 0.6 Contents UV sensor UVS 5... Contents...
More informationAutomation System TROVIS 5400 Boiler Controller TROVIS 5474
Automation System TROVIS 5400 Boiler Controller TROVIS 5474 Application Weather-sensitive control of up to two boilers, designed for single-stage, two-stage or also modulating operating mode. Communication
More informationInstallation and operating instructions
Installation and operating instructions Cascade module KM Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax 08751/741600 Internet: www.wolf-heiztechnik.de Part no. 30 62 449 Subject to modifications
More informationQuickheat 30 weather compensated boiler control
Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The
More informationSafety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11
050560 Edition. D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Ionization pilot burners,, Translation from the German 0 Elster GmbH Contents Checking the usage.....................
More informationRefrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301
Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control
More informationECL Comfort V a.c. and 24 V a.c.
230 V a.c. and 24 V a.c. Description and application The controller is designed for easy installation: one cable, one connector. The controller has a customdesigned display with backlight. For a quick
More informationWeekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.
Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. SHORT DESCRIPTION: 1. Device is applicable to: - Burners; - Electric boiler;
More informationRVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating
2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room
More informationMixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f
For the heating engineer/for the owner Operating and Installation Manual Mixer module VR 61 Mixer module for VRC 430 / VRC 430f VR 61 GB Contents Contents 1 Notes on the documentation 3 1.1 Storage of
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 is an electronic temperature controller which can be loaded with selected applications by means of an ECL Card. The ECL
More informationInsulation fault evaluator EDS460-DG
Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008
More informationprestige Control Application Supplement WARNING
prestige Control Application Supplement WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions within this
More informationInstallation & Operating Instructions IMage Pool Control Type
Installation & Operating Instructions IMage Pool Control Type 34-015040 International Marketing A/S reserves the right to make product changes without notice. Copyright: International Marketing A/S Edition
More informationProduct data sheet AIRWIN additional modules Accessories AIRWIN
Product data sheet AIRWIN additional modules Ozone module Item no. 2002004 Hygiene fresh produce humidification UB-12/18/24 Fan module KMB Item no. 2002003 Airflow AquaDrain module Item no. 2002001 Hygiene
More informationFLAME AMPLIFIER MODULE 3001
SYSTEM 3000 / 4000 FLAME AMPLIFIER MODULE 3001 TECHNICAL DESCRIPTION EDITION TB_3001_EN_REV03 BFI Automation Mindermann GmbH, Eggerscheidter Str. 57, D-40883 Ratingen Phone +49 (0) 2102 96 82 0, Fax +49
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather
More informationUser manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort
User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre
More informationGENERAL DESCRIPTION AND INSTRUCTIONS FOR KFG CONTROL
GENERAL DESCRIPTION AND INSTRUCTIONS FOR KFG CONTROL PANELS JUNE 2000 Contents General Information 3 Modular in Design 3 Technical Data 3 Installation Options 3 Description of Controls and Operation 4
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More informationISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationSelf-recuperative burner for gas
Self-recuperative burner for gas For direct and indirect heating Economical, energy-saving operation by virtue of internal air preheating up to 650 C Uniform distribution of temperature by means of a high
More informationECL Comfort 300 / V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL
More informationVIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer
Installation instructions for contractors VIESMANN Mixer extension kit For one heating circuit with mixer Mixer extension kit 5/2017 Safety instructions Please follow these safety instructions closely
More informationISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE
Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation
More informationPRELIMINARY EDITION
3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied
More informationHeating Controller for 2 heating circuits, d.h.w. and boiler, communicating
2 477 Heating Controller for 2 heating circuits, dhw and boiler, communicating RVP330 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated
More informationRemote alarm indicator and test combination MK2430
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC
More informationUse. Functions. Key function. Other functions
2 466 Heating Control System RVP102/SET Heating control system for use in smaller plants. Control of boiler temperature through direct burner control, pump control, weather-compensated setpoint (with or
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More information1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with
More informationRVL470. Heating Controller. Use. Functions. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationBIOMASS BOILER DUAL THERM
DUAL THERM PELLET/ WOOD BOILER AUTOMATIC FUEL SWAP BACK UP PROTECTION SYSTEM INTEGRATED IN BOILER HEAT EXCHANGER PELLET HOPPER INCLUDED HEAT EXCHANGER AND BURNER AUTOMATIC CLEANING SYSTEM AUTOMATIC LOG
More informationFor the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control
For the owner and the heating engineer Operating and Installation Manual VRC 400 Programmable weather compensator with separat HW time control GB Contents Contents Notes on the documentation..... 4 Symbols
More informationOperating Manual MS220KA and MSR220KA
Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße
More informationRVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products
2 478 Heating Controller for 2 heating circuits, d.h.w. and boiler RVP331 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated flow
More informationECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys
ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 310 controller series ECL 310 The ECL Comfort 310 is an electronic weather
More informationRVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER
Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page
More informationSC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS
FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS SC-3 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-3 Applications Space Heat Systems With Outdoor
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated
More informationT6984 A,D,E Electronic Floating Control Thermostats
T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series
More informationBM Programming Module. For the heating engineer Installation instructions
For the heating engineer Installation instructions BM Programming Module WOLF GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 www.wolf-heiztechnik.de Document no.: 3062612_201509 Subject to modifications
More informationOperating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 6 2.1 Before you start.....................................................
More informationUser manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT
User manual ABB i-bus EIB Zone Terminal MT/S 4.12.1 Intelligent Installation System ABB STOTZ-KONTAKT 2 Contents Page 1 Device configuration..................................... 4 1.1 Introduction..........................................
More informationInstallation Guide. ECL Comfort 310, application A Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................
More informationProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.
ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required
More informationPROMATIC WDC Heating controllers Energy under control
www.seltron.eu 205 PROMATIC WDC Heating controllers Energy under control 36 Made for warmth. PROMATIC WDC Heating controllers 37 PROMATIC WDC Heating controllers HIGHLIGHTS ycontrol of up to 52 different
More informationprestige Control Application Supplement - ACVMax
2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display
More informationSolar controllers Energy under control
www.seltron.eu 2015 PROMATIC SGC Solar controllers Energy under control For domestic hot water. 14 PROMATIC SGC Solar controllers 15 PROMATIC SGC Solar controllers HIGHLIGHTS ycontrol of up to 65 different
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationZIOU/230 - MAINS IO INSTRUCTION MANUAL
Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel
More informationControl Application. Supplement - ACVMax
prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationRVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning
G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationBosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler
Bosch Buderus SSB1000TL/TL2/TL3/TL4 Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB1000TL in quantities of. Bosch
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The
More informationfor contractors Vitosolic 100 Type SD1 For applicability, see the last page Please keep safe.
Installation and service instructions for contractors VIESMANN Electronic temperature differential control unit Vitosolic 100 Type SD1 For applicability, see the last page VITOSOLIC 100 4/2009 Please keep
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationB/S/H/ Fault Codes and Service Programmes PG
off on E:00 No error - - - - - - h:00 h:24 No error Appliance does not start Delay timer is activated! No appliance! All s are on s flashing Interface error Appliance without function Appliance without
More informationSuggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)
Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series
More informationTEC210x-2 Series Networked Thermostats
Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationT7984 A,B,C Electronic Modulating Control Thermostats
T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationCPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions
CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM8 CPM77 CPM96 CPM116 CPMSP116 CPM144 CPM17 CPM_ANCIL/CASCADE_V1._December 201 INDEX 1. INTRODUCTION...3 2. MAIN
More informationHot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological
Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution
More informationHeating and D.h.w. Controller RVL482 Basic Documentation
Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International
More informationECL Comfort V a.c. and 24 V a.c.
230 V a.c. and 24 V a.c. Description and application In heating applications the can be integrated with the Danfoss Link solution via the DLG interface for use in single-family applications. The controller
More informationWOLF GAS CONDENSING BOILERS COMFORTLINE
WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build
More informationACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.
Modulating temperature regulating unit for heating and cooling 7 series ACCREDITED ISO FM ا ٠١١٥٢/١٥ replaces /7 GB Function The temperature regulating unit is made to be used in radiant panel systems
More informationInstallation & Operating Instructions
FH-RT Wireless Room Thermostat FH-BU Wireless Base Unit Installation & Operating Instructions Specification Base unit (230 V) Order Code: Primary voltage: Secondary voltage: Outputs 1-6: Outputs 7-8: 088H011901
More informationInstaller manual ELK 213 Immersion heater
Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical
More informationINSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM
INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable
More informationInstallation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.
Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function
More informationCorrigo E. Second generation which contains all applications and languages
revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control
More information