SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

Size: px
Start display at page:

Download "SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles"

Transcription

1 System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF system cubicles /2 Introduction /3 8MF system cubicles /4 Preconfigured cubicles SIVACON 8MF/8MR system lighting /6 Compact/slimline lights /8 LED lights SIVACON 8MR system air-conditioning /10 Introduction /13 Filter fans / Air conditioners/cooling devices /17 Heat exchangers /18 Heater units /19 Fan heaters /21 Thermostats, hygrostats, hygrotherms, switching modules Additional information in Catalog LV 50. For further technical product information: Service & Support Portal: Product List: Technical specifications Entry List: Certificates / Characteristics / Download / FAQ / Manuals / Updates Siemens LV

2 System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF System Cubicles Introduction Overview Application SIVACON sicube offers a modular system for unequipped, empty enclosures. The system cubicles can be used in a variety of application areas and environments. Degrees of protection Available degrees of protection as standard: System cubicles without ventilation: IP40 and IP54 Preconfigured cubicles System cubicles with ventilation: IP20 to IP40 Further degrees of protection are available upon request. Available dimensions 8MF6 earthquake-resistant versions Minimum and maximum dimensions: Height: From 1800 mm to 2200 mm Width: From 600 mm to 1200 mm Depth: From 400 mm to 800 mm Special sizes available on request EMC versions The exact graduations can be found in "Order designations of the standard versions", see Catalog LV 50. Transport Cubicles are dispatched ex works on transport skids, or in the case of cubicle suites on transport bases. Structure A system cubicle comprises the following basic elements: Frame Enclosure Expansion A standard frame is supplied with the following standard enclosure parts: Rear panel Flat-panel roof Door with espagnolette lock and lock insert Side panels (for stand-alone installation) Versions Cutouts for special built-in components Double-wing doors Instrument covers Additional doors Roofs with busbar holders Doors with ventilation slots Perforated ventilation roofs Mounted units for cubicle air-conditioning For possible cubicle modifications, see Catalog LV 50. SIVACON sicube 8MF system cubicles are designed especially for: Open- and closed-loop control technology Power electronics Data systems SIVACON sicube 8MF system cubicles are also available for special applications, e.g. in special sizes: Applications: In nuclear power plants In case of increased vibrations (e.g. on excavators) In areas at risk of earthquakes Measures for enhancing electromagnetic compatibility (EMC) are becoming more and more important, both for individual devices and complete systems: Increasing processing speeds of communication systems Growing complexity of plants Contact between different systems working in a plant Different power levels More and more external interference sources /2 Siemens LV

3 System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF System Cubicles 8MF system cubicles Overview Application 8MF system cubicles are intended for the installation of devices and equipment for electronic and conventional open- and closed-loop control systems. The design allows subracks for 19-inch installations for the most varied industrial electronic systems or distribution modules for power distribution. Specific design measures permit 8MF6 cubicles with the dimensions H W = mm or mm to be supplied as earthquake-resistant versions for operation in nuclear power stations (see "8MF6 earthquake-resistant version", page /5). 8MF system cubicle Design 8MF2: Completely welded frame 8MF5: Welded side frame sections, screwed on lateral stays, delivery form: assembled 8MF6: Welded side frame sections, screwed-on lateral stays, delivery form: assembled Side and rear panels add 9 mm to the frame dimensions Ground clearance of doors: 63 mm Concealed hinges with an opening angle of 180 (130 for cubicle suites) Trim strips for labeling and integration of signaling lights Siemens LV /3

4 System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF System Cubicles Preconfigured cubicles Overview Ventilated cubicles 8MF2 (IP30/40) Compact designs and high packing densities demand special measures for heat dissipation. We offer ventilated cubicles in a preconfigured version, i.e. the complete cubicle can be ordered with one article number. Features Perforated roof plates Doors with 5 rows of ventilation slots High air throughput per unit of area thanks to special SBL ventilation design IP30 and IP40 degrees of protection available IP54 cubicles Special ambient conditions require a high degree of protection. Particularly its protection against splashing water makes this cubicle solution suitable for use on production lines and in other areas with sprinkler systems. Features Seals on all enclosure parts NSE0_01371a NSE0_01344 /4 Siemens LV

5 System Cubicles, System Lighting and System Air-Conditioning SIVACON sicube 8MF System Cubicles Preconfigured cubicles EMC cubicles To ensure a system's EMC, it is necessary that its devices emit only limited interference and are at the same time immune as far as possible to external interference. Features Cubicle frame and enclosure fully galvanized Paint finish only on the outer surfaces of doors and rear/side panels Conductive seals pre-mounted for doors and rear/side panels Additional standard base plate PC cubicles 8MF2 A variant of the 8MF system cubicles can also be ordered as a PC cubicle. The PC cubicle is a robust construction and is thus suitable for use in industrial environments. Features The standard door is replaced by: An upper compartment door (monitor cutout with inspection pane) A central hinged flap (with telescopic shelf for a keyboard) A lower compartment door (with shelf for a printer) Earthquake-resistant cubicles 8MF6 This cubicle is a certified earthquake-resistant system cubicle. An appropriate weight distribution and center of gravity are prescribed by the certification. The devices and components installed by the customer must also satisfy the relevant demands. Features Bracing stays at the top and bottom, plus a stay on the side Base plate with multiple divisions and foam rubber profile Corner bracings at the top and bottom Reinforcement plate NSE0_02135 Siemens LV /5

6 System Cubicles, System Lighting and System Air-Conditioning SIVACON 8MF/8MR System Lighting Compact/slimline lights Overview Rating of energy-saving lamps Rating of conventional incandescent lamps 9 W 60 W 11 W 75 W 20 W 100 W Spare lamp: Osram SPD1411-2B (100 W) Socket outlets Socket outlets are mounted on 35 mm support rails and connected without screws by way of three clamping terminals (for stranded and solid wires mm 2 ). The maximum operational voltage is 250 V. The enclosure is light-gray UL94 V-Q plastic. The slimline light is also available with country-specific socket outlets. Slimline light with motion detector Cubicle lighting The cubicle light is specifically suitable for operation in switchgear and controlgear cubicles. In the case of lights with a SCHUKO socket outlet, the outlet is incorporated with an on/off switch or motion detector in the plastic enclosure. The flat slimline light with motion detector or on/off switch is ideal for operation in cubicles and enclosures with a high density of built-in electrical/electronic components. All lamps are fitted with environmentally friendly energy-saving lamps. Plug-on mounts If a cubicle light is provided with a plug-on mount, it remains immune to vibration and can be removed at any later time without tools. If fitted between two plug-on mounts, the cubicle light is fixed statically to the cubicle frame. The cubicle light can only be fitted to the cubicle frame by using plug-on mounts. Selection and ordering data Version DT Article No. Price SET, M) kg Cubicle lighting Compact lights (355 x 65 x 70 mm) Without cover 230 V, 50 Hz, 11 W (Germany) 8MF unit V, 60 Hz, 9 W (Germany) 8MF unit V, 50 Hz, 11 W 8MF4900-1A 1 1 unit NSE0_01334 With cover 230 V, 50 Hz, 11 W 8MF unit With 3 m cable 8MF V, 50 Hz, 11 W 8MF4900-1B 1 1 unit With 3 m cable (orange-colored) 230 V, 50 Hz, 11 W 8MF4900-1BB 1 1 unit Spare parts for compact lights Spare lights 230V 8MR2023-0KL units Spare lights 120V 8MR2012-0KL units Covers 8MF units Dual lights (396 x 67 x 100 mm) V AC, Hz, 20 W With motion detector 8MF unit With on/off switch 8MF unit As hand-held lamp 8MF unit MF4902 /6 Siemens LV

7 System Cubicles, System Lighting and System Air-Conditioning SIVACON 8MF/8MR System Lighting Version DT Article No. Price Compact/slimline lights SET, M) kg Slimline lights (345 x 91 x 40 mm) 230 V, 50/60 Hz, 11 W with pushbutton (On/Off) With socket outlet D, without magnet 8MF5900-1A 1 1 unit With socket outlet D, with magnet ( 50 N) 8MF unit With socket outlet D, with magnet ( 30 N) 8MF5900-1C 1 1 unit Without socket outlet, without magnet 8MF5900-2A 1 1 unit Without socket outlet D, with magnet ( 50 N) 8MF5900-1B 1 1 unit Without socket outlet D, with magnet ( 30 N) 8MF5900-2B 1 1 unit MF5900-1A 8MF5910-1A Socket outlets Plug-on mounts 230 V, 50/60 Hz, 11 W with motion detector With socket outlet D, without magnet 8MF5910-1A 1 1 unit With socket outlet D, with magnet ( 50 N) 8MF unit With socket outlet D, with magnet ( 30 N) 8MF5910-1C 1 1 unit Without socket outlet, without magnet 8MF5910-2A 1 1 unit Without socket outlet D, with magnet ( 50 N) 8MF5910-1B 1 1 unit Without socket outlet D, with magnet ( 30 N) 8MF5910-2B 1 1 unit V DC, 11 W, with pushbutton (On/Off) Without socket outlet, without magnet 8MF5900-3A 1 1 unit Without socket outlet, with magnet ( 30 N) 8MF5900-3B 1 1 unit V DC, 11 W, with motion detector Without socket outlet, without magnet 8MF5910-3A 1 1 unit Without socket outlet, with magnet ( 30 N) 8MF5910-3B 1 1 unit Socket outlets with fuse VDE 8MF units CEBEC 8MF units Socket outlets without fuse VDE 8MF unit Plug-on mount For fitting the compact lights 8MF units NSE0_ MF4903 Position switches Position switch for mounting as door contact 1 NO + 1 NC 8MF unit NO + 2 NC 8MF unit MF4310/8MF4311 More information For more information, see Catalog LV 50 "SIVACON System Cubicles, System Lighting and System Air-Conditioning" or in the Industry Mall under "Low-Voltage Power Distribution and Electrical Installation Technology" --> "System Cubicles, System Lighting and System Air-Conditioning"--> "SIVACON 8MF/8MR System Lighting" Siemens LV /7

8 System Cubicles, System Lighting and System Air-Conditioning SIVACON 8MF/8MR System Lighting LED lights Overview LED light with on/off switch and magnetic fixing The LED lights with on/off switch are particularly suitable for operation in cubicles and enclosures with a high density of built-in electrical/electronic components. Thanks to the use of LED technology, these lights have a very long useful life. By means of magnetic fixing, they can be fastened anywhere in steel cubicles without installation effort. A version with screw fixing is available as before. Connection is made using a socket on the lamp (switch side). Another lamp can be connected using a connector (non-switch side). Up to 10 lights can be connected in series in this way. Features Technical data Power consumption, max. W 5 Light output corresponds to that of a 75 W incandescent lamp Endurance At 20 C h Connection General 2-pin plug-in connection with lock AC version Max. 2.5 A/240 V AC, color: white DC version Max. 2.5 A/60 V DC, color: blue Dimensions Length mm 351 Light diameter mm 32 Mounting width Light with magnetic fixing mm 34 Light with screw fixing mm 52 Permissible ambient temperature Operation C Storage C Degree of protection IP20 Safety class II (protective insulation) Note: Delivery does not include plugs, sockets and cables for electrical connection. These must be ordered separately. See accessories on next page. Selection and ordering data LED lights with pushbutton (On/Off) Magnetic fixing Version DT Article No. Price SET, M) kg V AC, 50 Hz /60 Hz 8MR2200-1A 1 1 unit MR2200-1A V DC 8MR2201-1A 1 1 unit MR2201-1A 8MR2200-1B Screw fixing V AC, 50 Hz /60 Hz 8MR2200-1B 1 1 unit V DC 8MR2201-1B 1 1 unit /8 Siemens LV

9 Accessories System Cubicles, System Lighting and System Air-Conditioning SIVACON 8MF/8MR System Lighting Individual plugs or sockets 8MR2210-1A Cables 8MR2210-1B 8MR2210-1C 8MR2210-3C Position switches Version DT Article No. Price AC socket for input side, white SET, M) LED lights For connection of an LED light (switch side) 8MR2210-1A 1 10 units AC plug for output side, white For looping through to another LED light 8MR2210-2A 1 10 units DC socket for input side, blue For connection of an LED light (switch side) 8MR2210-3A 1 10 units DC plug for output side, blue For looping through to another LED light 8MR2210-4A 1 10 units Note: Plugs and sockets are also separately available for self-assembling cables that deviate from standard lengths. Connecting cable with socket and open end, each 2 m long For connection of a lamp (switch side) AC connecting cable 2 x 1.5 mm 2 with socket, VDE 8MR2210-1B 1 5 units AC connecting cable AWG with socket, UL 8MR2210-2B 1 5 units DC connecting cable 2 x 1.5 mm 2 with socket, VDE 8MR2210-3B 1 5 units DC connecting cable AWG with socket, UL 8MR2210-4B 1 5 units Extension cable for cascading, each 1 m long, with socket and plug AC light plastic-sheathed cable 2 x 1.5 mm 2 with socket and plug, VDE AC light plastic-sheathed cable AWG with socket and plug, UL DC light plastic-sheathed cable 2 x 1.5 mm 2 with socket and plug, VDE DC light plastic-sheathed cable AWG with socket and plug, UL Position switch for mounting as door contact 8MR2210-1C 1 5 units MR2210-2C 1 5 units MR2210-3C 1 5 units MR2210-4C 1 5 units NO + 1 NC 8MF unit NO + 2 NC 8MF unit kg 8MF4310/8MF4311 More information For more information, see Catalog LV 50 "SIVACON System Cubicles, System Lighting and System Air-Conditioning" or in the Industry Mall under "Low-Voltage Power Distribution and Electrical Installation Technology" --> "System Cubicles, System Lighting and System Air-Conditioning"--> "SIVACON 8MF/8MR System Lighting" Siemens LV /9

10 System Cubicles, System Lighting and System Air-Conditioning Introduction Overview 8MR system air-conditioning Filter fans Standard filter fans, IP54 or IP55 Control supply voltage or voltage for switching capacity 24/48 V DC 115 V AC 230 V AC 400/440 V AC With or without additional EMC protection -- Cooling capacity 8 W/K W/K -- Air rate 25 m 3 /h m 3 /h -- Size mm to 292 mm 292 mm -- Color RAL 7035 or RAL Roof filter fans, IP44 Cooling capacity 113 W/K W/K Air rate 350 m 3 /h m 3 /h Size 430 mm 430 mm to 470 mm 470 mm Color RAL 7035 or RAL Air conditioners/cooling devices For door and side mounting (recessed) W For roof mounting W Heat exchangers Standard Air/air (at T = 20 K) For side and door mounting W Heater units optionally without or with thermostat 10 W W -- Fan heaters optionally without or with thermostat 100 W W -- Setting ranges C, F -- Thermostats, hygrostats, hygrotherms, switching modules Thermostats, optionally NC, NO, CO contacts Setting ranges C Switching capacities up to A -- Hygrostats, changeover contacts % relative air humidity Hygrotherms, optionally NC, NO, CO contacts Setting ranges C, F % relative air humidity Switching capacities 6 (1) A... 8 (1.6) A -- Switching modules A Available or possible -- Not available or not possible On request The figures in brackets indicate inductive switching capacities. /10 Siemens LV

11 System Cubicles, System Lighting and System Air-Conditioning Benefits Installing air-conditioning equipment in SIVACON sicube cubicle systems ensures high fault tolerance for switchgear and controlgear assemblies and consequently a high level of availability of machines and plants. Introduction Application In control cubicles, depending on the ambient conditions (e.g. heat, cold, air humidity etc.), there may be a tendency to overheat or for mold to form. In such cases the cubicles should be air-conditioned. The following air-conditioning equipment is available for this purpose: Filter fans Air conditioners/cooling devices Heat exchangers, air/air Heaters/thermostats When selecting individual air-conditioning components, the ambient temperature, the power losses of the installed devices, the maximum permissible device temperature and the heat dissipation capacity of the cubicle used are the factors to be considered. In addition, it is necessary to take into account the required degree of protection. Optimum, extended air duct for the system air-conditioning 35 C Hot air from the equipment and busbars Cubicle Cold air recirculation 25 C 55 C NSE0_01390a System air-conditioning optimum air duct More information Further information, see Industry Mall under "Building Technologies": "Low-Voltage Power Distribution and Electrical Installation Technology" --> "SIVACON Switchboards and Busbar Trunking Systems" --> "System Cubicles, System Lighting and System Air-Conditioning" --> "" Siemens LV /11

12 System Cubicles, System Lighting and System Air-Conditioning Introduction Configuring guide Step 1: Dimensions Determine the cubicle's height, width and depth Step 2: Installation type Determine the cubicle's installation types in compliance with VDE 0660 T500 Single enclosure, free-standing on all sides Single enclosure for wall mounting Calculation Legend for formulas below: A Cubicle area in m 2 W Width in m H Height in m D Depth in m A = 1.8 x H x (W + D) x W x D A = 1.4 x W x (H + D) x D x H Graphic representation or determination The diagrams below illustrate the installation types in the top view Start and end enclosures, free-standing A = 1.4 x D x (H + W) x W x H Start and end enclosure for wall mounting A = 1.4 x H x (W + D) x W x D Middle enclosure, free-standing A = 1.8 x W x H x W x D + D x H Middle enclosure for wall mounting A = 1.4 x W x (H + D) + D x H Middle enclosure for wall mounting, with covered roof surfaces A = 1.4 x W x H x W x D + D x H Step 3: Cubicle material Determine the cubicle's material its coefficient of heat transmission k in W/m 2 K Step 4: Temperature difference Determine the required difference between interior and exterior temperature Step 5A: Heating output If heating is required, determine the required heating output either with the adjacent formula or from the diagram on the extreme right Note: If power loss P V (intrinsic heating) is constant, it must be deducted from the calculated heating output Step 5B: Cooling capacity Example: Cubicle, free-standing on all sides, 2000 mm high, 800 mm wide, 600 mm deep. A = 1.8 m x 2.0 m x (0.8 m+ 0.6 m) m x 0.8 m x 0.6 m = m 2 Accordingly, the cubicle has an area of m 2. Varnished sheet steel: k = 5.5 W/m 2 K Stainless sheet steel: k = 4.5 W/m 2 K Aluminum: k = 12 W/m 2 K Aluminum, double-walled: k = 4.5 W/m 2 K Polyester: k = 3.5 W/m 2 K T= T i - T u Legend for formula: T Temperature difference in K (Kelvin) T i Interior temperature in C T u Exterior temperature in C P H = A x k x T Select required heating output from diagram: Legend for formula: P H Required heating output in W A Cubicle area in m 2 k Coefficient of heat transmission in W/m 2 K T Temperature difference in K Example: Cubicle area A= m 2, coefficient of heat transmission k = 5.5 W/m 2 K, temperature difference = 15 K P H = m 2 x 5.5 W/m 2 K x 15 K = W A heater with 500 W heating output is required. When installed outdoors, the calculated heating output must be doubled. V = f x P v / T If cooling is required, determine the necessary Legend for formula: cooling capacity either according to the adjacent formula or from the diagram on the extreme right V f P V Required volumetric flow in m 3 /h Air constant in m 3 K/Wh (see bottom left) Power loss in W T Temperature difference in K Note on the air constant f: Example: Installed power loss = 600 W, temperature difference = 15 K, installation altitude = 400 m The altitude at the point of use (above mean sea level) determines the air constant f. Decreasing barometric pressure or air density above mean sea level V = 3.3m 3 K/Wh x 600 W/15 K = 132 m 3 /h with rising altitude is taken into consideration A fan with 0 m 3 /h air capacity is required. via the air constant. f ( m) = 3.1 m 3 K/Wh f ( m) = 3.2 m 3 K/Wh, f ( m) = 3.3 m 3 K/Wh, f ( m) = 3.4 m 3 K/Wh f ( m) = 3.5 m 3 K/Wh Heating output W Control cubicle surface m 2 Select required cooling output from diagram: Thermal power loss P V in W Volume flow rate m 3 /h T 20 K T 15 K T 10 K T 5 K I201_188 I201_ /12 Siemens LV

13 System Cubicles, System Lighting and System Air-Conditioning Filter fans Overview Filter fans are the most cost-effective method - after heat dissipation through the surface of a control cubicle and/or ventilation openings in the enclosure parts of the control cubicles - for dissipating heat from control cubicles. However, this can only achieve a control cubicle temperature which lies above the ambient temperature. Standard filter fans optionally in EMC version When filter fans are used for air-conditioning, the cubicle must have openings which allow electromagnetic radiation to pass in and out unobstructed. Filter fans in EMC version offer additional protection when higher requirements are imposed on electromagnetic compatibility. Filter fan versions The following filter fans are available on request: Standard filter fan IP54, color RAL 7035/7032 Standard filter fan IP55, color RAL 7035/7032 Standard filter fan EMC, color RAL 7035/7032, IP54 Standard filter fan EMC, color RAL 7035/7032, IP55 Note: For all standard filter fans the useful cooling capacity and air rate are reduced by an average of 30 % in combinations of filter fan / outlet filter / filter mat, and for roof filter fans by 40 %. Selection and ordering data Filter fans 8MR6411-5LV10 8MR6511-5LV10 Degree of protection Size Air current, free-blowing at 50 Hz Cutout Voltage Input rating at 50 Hz Color DT Article No. Price SET, M) RAL m 3 /h mm V W kg Filter fans 50/60 Hz except 8MR6402-2LV41 IP AC MR6411-5LV unit AC MR6423-2LV unit AC MR6423-5LV unit AC MR6411-5LV unit AC MR6423-2LV unit AC MR6423-5LV unit AC MR6411-5LV unit AC MR6423-5LV unit AC MR6411-5LV unit AC MR6423-2LV unit AC MR6423-5LV unit DC MR6402-2LV unit AC MR6411-5LV unit AC MR6423-2LV unit AC MR6423-5LV unit AC MR6411-5LV unit AC MR6423-2LV unit AC MR6423-5LV unit AC MR6411-5LV unit AC MR6423-5LV unit IP AC MR6511-5LV unit AC MR6523-5LV unit AC MR6511-5LV unit AC MR6523-5LV unit AC MR6511-5LV unit AC MR6523-5LV unit AC MR6511-5LV unit AC MR6423-5LV unit AC MR6511-5LV unit AC MR6523-5LV unit AC MR6511-5LV unit AC MR6523-5LV unit Siemens LV /13

14 System Cubicles, System Lighting and System Air-Conditioning Filter fans Degree of protection Size EMC filter fans IP54 Air current, free-blowing at 50 Hz Cutout Voltage Input rating at 50 Hz Color DT Article No. Price SET, M) IP AC MR6411-6LV unit AC MR6423-6LV unit AC MR6411-6LV unit AC MR6423-6LV unit AC MR6411-6LV unit AC MR6423-6LV unit RAL m 3 /h mm V W kg 8MR6411-6LV30 EMC filter fans IP55 IP AC MR6511-6LV unit AC MR6523-6LV unit AC MR6511-6LV unit AC MR6523-6LV unit AC MR6511-6LV unit AC MR6523-6LV unit MR6511-6LV30 Outlet filters 8MR6400-5GV67 Size Dimensions Color DT Article No. Price Cutout External Mounting Cover RAL dimensions grille W H depth height SET, M) mm mm mm mm kg Outlet filters IP , MR6400-2GV unit MR6400-5GV unit , MR6400-2GV unit MR6400-5GV unit MR6400-5GV unit MR6400-2GV unit MR6400-5GV unit , MR6400-2GV unit MR6400-5GV unit Outlet filters IP , MR6500-5GV unit MR6500-5GV unit MR6500-5GV unit , MR6500-5GV unit MR6500-5GV67 EMC outlet filters IP MR6400-6GV unit MR6400-6GV unit EMC outlet filters IP MR6500-6GV unit MR6500-6GV unit MR6400-6GV30 /14 Siemens LV

15 Filter mats 8MR6000-0AM10 System Cubicles, System Lighting and System Air-Conditioning Size Dimensions DT Article No. Price W H SET, M) mm Filter mats for filter fans or outlet filters for IP54 Filter fans approx MR6000-0AM units MR6000-0AM units MR6000-0AM units MR6000-0AM units MR6000-0AM units kg Roof filter fans Air current, Dimensions Voltage Input free-blowing at 50 Hz Cutout External rating dimensions W H D DT Article No. Price SET, M) m 3 /h mm mm V W kg Roof filter fans IP44 for 50/60 Hz, color RAL /45 8MR6311-5DL unit /45 8MR6323-5DL unit /130 8MR6311-5DL unit /130 8MR6323-5DL unit MR6323-5DL40 Roof outlet filters IP44, color RAL 7035 Without fan MR6000-5DE unit MR6000-5DE40 19" withdrawable fan unit Power Voltage Series DT Article No. Price SET, M) W V kg LE 019 8MR2190-1A 1 1 unit MR2190-1A Siemens LV /15

16 System Cubicles, System Lighting and System Air-Conditioning Air conditioners/cooling devices Overview 8MR6 cooling devices: Door or side mounting top left, roof mounting bottom right Where ambient temperatures are higher than the permissible device temperatures, air conditioners must be used. All units operate with CFC-free refrigerants. Air conditioners dehumidify the air inside the control cubicle. Cooling devices for door or side mounting and roof mounting Two separate air circuits ensure that no ambient air enters the control cubicle. High-performance radial fans provide for good air circulation in the control cubicle. Intelligent standard electronics with maximum customer benefits: Simple temperature control with an integrated thermostat Test mode Temperature limits Start-up delay Door contact function Alarm contact Local diagnostics UL-approved CE-approved Versions Air conditioners/cooling devices are available in the following versions: For side and door mounting For roof mounting Selection and ordering data Cooling devices for door or side mounting, degree of protection inside IP54/outside IP34, color RAL 7035 Cooling Rated power Dimensions Air capacity DT Article No. Price capacity W H D internal/ external SET, W W mm m 3 /h M) kg Cooling devices for 230 V, 50/60 Hz 1) /280 8MR6423-5EG unit /570 8MR6423-5EG unit /570 8MR6423-5EG unit ) /860 8MR6423-5SK unit ) /1050 8MR6423-5SK unit ) /1050 8MR6423-5SK unit MR6423-5SK20 Cooling devices for 400 V, 50/60 Hz 1) /1450 8MR6440-5EG unit /1450 8MR6440-5EG unit /2900 8MR6440-5EG unit ) Surface mounting and full integration possible. 2) Partial integration possible. Cooling devices for roof mounting, degree of protection inside IP54/outside IP34, color RAL 7035 Cooling capacity Rated power Dimensions Air capacity W H D internal/ external DT Article No. Price SET, M) W W mm m 3 /h kg Cooling devices for 230 V, 50/60 Hz /330 8MR6423-5DE unit /570 8MR6423-5DE unit /1010 8MR6423-5DE unit /1820 8MR6423-5DE unit /1820 8MR6423-5DE unit Cooling devices for 400 V, 50/60 Hz /3410 8MR6440-5DE unit /3410 8MR6440-5DE unit / Siemens LV

17 System Cubicles, System Lighting and System Air-Conditioning Heat exchangers Overview Air/air principle Heat exchangers designed on the air/air principle function with two completely separate air circuits: an internal and an external circuit. One fan draws in cool external air. A second fan then directs the warmed air inside the cubicle past a large-area finned partition element, which passes the heat to the external circuit. Note: The devices can be surface mounted and fully integrated. Heat exchanger 80 W/K Selection and ordering data Air/air heat exchangers, degree of protection IP54, color RAL 7035 Thermal power Rated power Dimensions Air capacity W H D internal/external DT Article No. Price SET, M) W/K W mm m 3 /h kg Heat exchangers for 230 V, 50/60 Hz /570 8MR6423-5ML unit /1050 8MR6423-5ML unit MR6423-5ML80 Siemens LV /17

18 System Cubicles, System Lighting and System Air-Conditioning Heater units Overview Control cubicle heater units are used for preventing malfunctions due to condensation water and corrosion and for controlling the temperature inside the control cubicle (observance of a minimum temperature). The plastic enclosure is designed such that the surface temperatures on the touchable side areas are kept very low. The heater units are designed for uninterrupted duty. All units are also available in UL-approved versions and for special voltages. Small semiconductor heater unit, 8MR2131-0A Selection and ordering data Heater units 8MR2130-1A 8MR2131-4A 8MR2132-1A 8MR2110-3BA Version DT Article No. Price SET, M) kg Heater units, UL-approved, with PTC thermistor V AC/DC 15W 8MR2130-1A 1 2 units W 8MR2130-3A 1 2 units W 8MR2130-4A 1 1 unit W 8MR2130-6A 1 1 unit W 8MR2130-7A 1 1 unit W 8MR2130-0A 1 1 unit W 8MR2130-5A 1 1 unit Semiconductor heater units without thermostat, degree of protection IP20, UL-approved, compact design V AC/DC 50 W 8MR2131-4A 1 1 unit W 8MR2131-0A 1 1 unit W 8MR2131-5A 1 1 unit Semiconductor heater units with thermostat, degree of protection IP20, compact design V AC/DC 50 W, 15 C 8MR2132-1A 1 1 unit W, 25 C 8MR2132-1AB 1 1 unit W, 15 C 8MR2132-0A 1 1 unit W, 25 C 8MR2132-0AB 1 1 unit W, 15 C 8MR2132-5A 1 1 unit W, 25 C 8MR2132-5AB 1 1 unit Small semiconductor heater unit V AC/DC 30 W 8MR2110-3BA 1 1 unit Screw fixing for small semiconductor heater unit 8MR2110-1BB 1 1 unit Semiconductor heater unit V AC/DC 15 W 8MR2130-1BA 1 1 unit W 8MR2130-3BA 1 1 unit W 8MR2130-4BA 1 1 unit /18 Siemens LV

19 System Cubicles, System Lighting and System Air-Conditioning Fan heaters Overview Where higher heating outputs (from 150 W) are required, fan heaters are used. The integrated fans provide for better air circulation and hereby achieve a more uniform air temperature distribution in the control cubicle. All units are also available in UL-approved versions and for special voltages. Fan heaters with integrated thermostat or hygrostat Selection and ordering data Fan heaters 8MR2140-0A 8MR2140-0B 8MR2122-4A Version DT Article No. Price SET, M) Fan heaters in standard version UL-approved Without fan V AC, 100 W 8MR2140-0A 1 1 unit V AC, 150 W 8MR2140-1A 1 1 unit V AC, 200 W 8MR2140-2A 1 1 unit V AC, 300 W 8MR2140-3A 1 1 unit V AC, 400 W 8MR2140-4A 1 1 unit V AC, 600 W 8MR2140-6C 1 1 unit With fan V AC, 100 W 8MR2140-0B 1 1 unit V AC, 150 W 8MR2140-1B 1 1 unit V AC, 200 W 8MR2140-2B 1 1 unit V AC, 300 W 8MR2140-3B 1 1 unit V AC, 400 W 8MR2140-4B 1 1 unit V AC, 600 W 8MR2140-6D 1 1 unit Compact fan heaters With fan, UL-approved V AC, 250 W 8MR2122-4A 1 1 unit V AC, 400 W 8MR2122-8A 1 1 unit V AC, 250 W 8MR2122-4B 1 1 unit V AC, 400 W 8MR2122-8B 1 1 unit With fan - 24 V DC, 250 W 8MR2122-4AB 1 1 unit V DC, 250 W 8MR2122-4AC 1 1 unit V DC, 400 W 8MR2122-8AA 1 1 unit kg Siemens LV /19

20 System Cubicles, System Lighting and System Air-Conditioning Fan heaters Version DT Article No. Price SET, M) Fan heaters with integrated thermostat or hygrostat 230 V AC, 950 W Fan heaters, UL-approved, for floor mounting - Temperature range C 8MR2150-0A 1 1 unit % relative air humidity 8MR2150-0BA 1 1 unit kg 8MR2150-0A Fan heaters, UL-approved, for wall mounting - Temperature range C 8MR2150-0C 1 1 unit % relative air humidity 8MR2150-0CA 1 1 unit MR2150-0C Semiconductor fan heaters Fan heaters UL-approved With clip fixing for 35 mm standard mounting rail V AC, 150 W 8MR2150-2C 1 1 unit V AC, 250 W 8MR2150-5A 1 1 unit V AC, 350 W 8MR2140-3C 1 1 unit V AC, 400 W 8MR2150-4A 1 1 unit V AC, 550 W 8MR2140-5C 1 1 unit MR2150-5AA V AC, 250 W 8MR2150-5AA 1 1 unit V AC, 350 W 8MR2140-3D 1 1 unit V AC, 400 W 8MR2150-4AA 1 1 unit V AC, 550 W 8MR2140-5D 1 1 unit With screw fixing V AC, 150 W 8MR2150-2D 1 1 unit V AC, 250 W 8MR2150-5B 1 1 unit V AC, 400 W 8MR2150-4B 1 1 unit V AC, 250 W 8MR2150-5AB 1 1 unit V AC, 400 W 8MR2150-4AB 1 1 unit MR2150-5B 8MR2151-3A (Illustration similar) PTC fan heaters for wall mounting UL-approved, 1200 W, clip fixing for 35 mm standard mounting rail or screw fixing (M6) 230 V AC, with thermostat, C 8MR2150-3A 1 1 unit V AC, without thermostat 8MR2150-3B 1 1 unit V AC, with thermostat F 8MR2151-3A 1 1 unit V AC, without thermostat 8MR2151-3B 1 1 unit PTC fan heaters for floor mounting UL-approved, 1200 W, screw fixing (M5) 230 V AC, with thermostat, C 8MR2150-2A 1 1 unit V AC, without thermostat 8MR2150-2B 1 1 unit V AC, with thermostat F 8MR2151-2A 1 1 unit V AC, without thermostat 8MR2151-2B 1 1 unit MR2151-2A (Illustration similar) /20 Siemens LV

21 System Cubicles, System Lighting and System Air-Conditioning Thermostats, hygrostats, hygrotherms, switching modules Overview Tamper-proof thermostat, NC contact Thermostats Thermostats (as NC, NO or CO contacts) are used to regulate cooling devices, filter fans and heat exchangers, as well as to trigger signals in case of excessive temperatures. Hygrostats Hygrostats are used to regulate heaters/fan heaters so that the temperature increase raises the dew point from a critical humidity of 65 % in cubicles and enclosures with built-in electrical and electronic components. This prevents condensation on structural parts and electronic components. Hygrotherms Hygrotherms monitor both temperature and relative humidity in cubicles and enclosures with built-in electrical/electronic components and switch on a heater or fan upon reaching the selected values (temperature or relative humidity). This prevents condensation on structural parts and electronic components. Switching modules Switching modules are electronic relays for the switching of high-power DC devices. Thermostats, hygrostats or hygrotherms can be connected to operate the switching modules. Note: The switching capacity values quoted in brackets refer to inductive loads. Selection and ordering data Thermostats 8MR2170-2BA Version DT Article No. Price SET, M) Small thermostats UL-approved, max. switching capacity 250 V AC, 10 (2) A NC contacts kg - Temperature range C 8MR2170-2BA 1 5 units Temperature range C 8MR2170-1CA 1 5 units Temperature range C 8MR2170-1DA 1 5 units NO contacts - Temperature range C 8MR2170-2BB 1 5 units Temperature range C 8MR2170-1CB 1 5 units Temperature range C 8MR2170-1DB 1 5 units MR2170-2BB 8MR2171-1BA Tamper-proof thermostats UL-approved, max. switching capacity 250 V AC, 5 (1.6) A NC contacts - Temperature range 15 C / 59 F (5 C / 41 F) 8MR2171-1BA 1 5 units Temperature range 25 C / 77 F (15 C / 59 F) 8MR2171-2BA 1 5 units NO contacts - Temperature range 50 C / 122 F (40 C / 104 F) 8MR2171-1BB 1 5 units Temperature range 60 C / 140 F (50 C / 122 F) 8MR2171-2BB 1 5 units Temperature range 35 C / 95 F (25 C / 77 F) 8MR2171-3BB 1 5 units MR2171-1BA Siemens LV /21

22 System Cubicles, System Lighting and System Air-Conditioning Thermostats, hygrostats, hygrotherms, switching modules Version DT Article No. Price SET, M) Mechanical thermostats UL-approved Changeover contact C, max. switching capacity 250 V AC, 10 (4) A Changeover contact C, max. switching capacity 250 V AC, 10 (4) A 8MR2170-1A 1 2 units MR2170-1B 1 1 unit kg 8MR2171-1A 8MR2170-1GA Electronic thermostats Changeover contact C, max. switching capacity 230 V AC, 8 (1.6) A Changeover contact C, max. switching capacity 120 V AC, 8 (1.6) A Changeover contact (inverted) C, max. switching capacity 230 V AC, 8 (1.6) A CO contact, C, max. switching capacity 24 V DC, A Twin thermostats NO and NO contacts, C, max. switching capacity 250 V AC, 10 (2) A NC and NO contacts, C, max. switching capacity 250 V AC, 10 (2) A 8MR2170-1GA 1 1 unit MR2170-1GB 1 1 unit MR2170-1GC 1 1 unit MR2170-2A 1 1 unit MR2170-1EA 1 1 unit MR2170-1E 1 2 units MR2170-1EA 8MR2172-1A Hygrostats Twin thermostats (tamper-proof) NC contact, 15 C/59 F (5 C/41 F) and NO contact, 50 C/122 F (40 C/104 F) max. switching capacity 250 V AC, 5 (1.6) A NC contact, 25 C/77 F (15 C/ 59 F) and NO contact, 60 C/140 F (50 C/122 F) max. switching capacity 250 V AC, 5 (1.6) A or 30 W DC NO contact, 50 C/122 F (40 C/104 F) and NO contact, 60 C/140 F (50 C/122 F) max. switching capacity 250 V AC, 5 (1.6) A 8MR2172-1A 1 3 units MR2172-2A 1 3 units MR2172-1AB 1 3 units Hygrostats are used to regulate heaters/fan heaters so that the temperature increase raises the dew point Mechanical hygrostats 8MR2170-1C 1 1 unit UL-approved CO contact, 230 V AC, % relative air humidity Max. switching capacity 250 V AC, 5 (0.2) A or 20 W AC Min. switching capacity 20 V AC/DC, 100 ma Electronic hygrostats 230 V AC % relative air humidity Max. switching capacity 240 V AC, 8 (1.6) A 120 V AC % relative air humidity Max. switching capacity 120 V AC, 8 (1.6) A 8MR2170-1AF 1 1 unit MR2170-2AF 1 1 unit MR2170-1AF 230 V AC 65 % relative air humidity Max. switching capacity 240 V AC, 8 (1.6) A 120 V AC 65 % relative air humidity Max. switching capacity 120 V AC, 8 (1.6) A 8MR2170-1BF 1 1 unit MR2170-2BF 1 1 unit MR2170-1BF /22 Siemens LV

23 Hygrotherms System Cubicles, System Lighting and System Air-Conditioning Thermostats, hygrostats, hygrotherms, switching modules Electronic hygrotherms UL-approved, % relative air humidity, for simultaneously monitoring both temperature and relative humidity in cubicles and enclosures with electronic components, CO contacts V AC, +32 to +140 F, max. switching capacity of NC contacts: 120 V AC, 6 A (1) A, Max. switching capacity of NO contacts: 120 V AC, 8 (1.6) A V AC, C, max. switching capacity of NC contacts: 8MR2170-4F V AC, 6 (1) A, Max. switching capacity of NO contacts: V AC, 8 (1.6) A Switching modules Switching modules Electronic relay for switching high-power DC devices from thermostats, hygrostats or hygrotherms Version DT Article No. Price SET, M) 8MR2170-4F 1 1 unit MR2170-4E 1 1 unit V DC, A 8MR2180-1A 1 1 unit V DC, A 8MR2180-1B 1 1 unit kg 8MR2180-1A More information Further information, see Industry Mall under "Building Technologies": "Low-Voltage Power Distribution and Electrical Installation Technology" --> "SIVACON Switchboards and Busbar Trunking Systems" --> "System Cubicles, System Lighting and System Air-Conditioning" --> "" Siemens LV /23

24 System Cubicles, System Lighting and System Air-Conditioning Notes /24 Siemens LV

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories Product Catalogue Content Heating Small semiconductor Heater HGK 047 Series 3 Semiconductor Heater HG 040 Series 4 Semiconductor Heater HG 140 Series 5 Semiconductor Heater CS 060 Series 6 Semiconductor

More information

electronics Protection

electronics Protection Climate control electronics PROTECTION 10/2017 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk Main Catalogue Content Cabinets...... 1 Climate control Overview Wall mounted cases......... 2 Accessories for cabinets

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue Product Catalogue Thermal Management Products & Accessories from STEGO successfully used worldwide for control panels and enclosures for traffic control and monitoring systems in the transport industry

More information

Thermal management for your cabinets!

Thermal management for your cabinets! ELECTRIC CABINET HEATERS LIGHTS CONTROLLER ELECTRIC CABINET COOLERS Thermal management Thermal management for your cabinets! MORE THAN 55 YEARS the specialist for individual electric cabinet heaters and

More information

Life insurance for your electronics

Life insurance for your electronics ELECTRO-TECHNOLOG FOR INDUSTR Life insurance for your electronics The formation of condensation is one of the biggest dangers for electrical enclosures. As long as they are working under load, their own

More information

Cooling unit Mechanical control

Cooling unit Mechanical control ClimaSys CU Cooling unit Mechanical control Top-mounting models, ref. NSYCU760W2VR- NSYCU10W2VR- NSYCU1460W2VR J 26 A B 8 K 2 0 C D E H F G Cut-out template for top mounting without intermediate frame.

More information

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 04 eat exchangers One concept, two systems with very different operating methods Air/water heat

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal

More information

Eldon Product Overview

Eldon Product Overview Eldon Product Overview Product overview Floor Standing Enclosures page 4 Thermal Management page 32 Human Machine Interface page 26 Wall Mounted Enclosures page 12 Accessories page 38 Terminal Boxes page

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

VA G 052 S

VA G 052 S 763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY

More information

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV FILTER FANS SERIES LV ROOF MOUNTED FAN For the ventilation of control cabinets, enclosures and housings Different filter mats for dust collection LV series offers low shape and quick mounting EMC versions

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about

More information

Heaters, Thermostats and Hygrostats

Heaters, Thermostats and Hygrostats Heaters, Thermostats and Hygrostats 154 Automática Electrónica y Control, S.L. Lacy, 30 Acc. - 08202 Sabadell (Barcelona) Tel 937 207 066 Fax 937 209 999 www.automatica-elec.es info@automatica.cat ELECTRO-TECHNOLOGY

More information

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes Spec-728 CPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 STEGO Catalogue 2018 Global presence in Thermal Management This catalogue contains the full range of STEGO products for protection of electronic

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model 18 Product Overview : Makes electronics cooling easier, so you can go about your business SPECTRACOOL

More information

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management Reyrolle Protection Devices 7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management 7XG3130 - RA30 Optical Arc Fault Sensor Features Compact rugged design One or two optical detectors High speed arc

More information

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems: Overview Adjustable thermostats O (blue button) with normally open contact to control the starting of a fan when the temperature exceeds the displayed maximum value. C (red button) with normally closed

More information

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 2 COMPANY PRODUCT CATALOGUE - STEGO STEGO Catalogue 2018 STEGO - PRODUCT CATALOGUE PERFECT THERMAL MANAGEMENT 3 Global presence in Thermal Management

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.3200 SPEC-00728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 BTU/Hr. Watt G52 / BTU/Hr. 2300/3500 Watt

More information

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40 Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for

More information

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface Everyone talks about the future, but Rittal helps shape it and that includes the field of climate control. Development work focuses on the holistic protection of process control with the minimum possible

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures

More information

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt Spec-728 E Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

Glass Door Merchandiser. Model RM-45-SD

Glass Door Merchandiser. Model RM-45-SD Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

SPECTRACOOL INDOOR/OUTDOOR

SPECTRACOOL INDOOR/OUTDOOR SPEC-728 E SEALED ENCLOSURE AIR CONDITIONERS SEALED ENCLOSURE AIR CONDITIONERS SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection 7 0 Selection guide TO CONTROL THE TEMPERATURE Respects the entered value Compact fixed thermostats Preset factory temperature: NA (blue button):, 0, ºC for the resistance heater. (red button):, 0, ºC

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners 763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.32 SPEC-728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

Rittal roof-mounted fans Efficiency on top

Rittal roof-mounted fans Efficiency on top Rittal roof-mounted fans Efficiency on top 2 Climate control/roof-mounted fans The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled our

More information

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes Spec-75 A( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Glass Door Merchandiser. Model RM-49

Glass Door Merchandiser. Model RM-49 Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

Quality Enclosures. Service Excellence.

Quality Enclosures. Service Excellence. Cooling Products General Information...5 General Selection Considerations...5 Sizing an Air Conditioner...6 General Specifications for Air Conditioners...7 Side Mounting DTS Series Air Conditioners 1200

More information

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector Product DELTA i-system DELTA profil titanium white 5WG1 258-2HB11 pearl grey 5WG1 255-2AB01 carbon metallic 5WG1 258-2HB21 titanium white 5WG1 255-2AB11 aluminum metallic 5WG1 258-2H1 anthracite 5WG1 255-2AB21

More information

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt Spec-75 B Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527 Watt INDUSTRY STANDARDS UL/cUL Listed;

More information

Excellent performance with low operating costs, Energy saving and environmentally friendly

Excellent performance with low operating costs, Energy saving and environmentally friendly BOGE compressed air centre C 20 LDR 350 air cooled Screw compressor with BOGE energy saving refrigerant compressed air dryer on horizontal compressed air receivers Complete and ready to connect, fully

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

Glass Door Merchandiser

Glass Door Merchandiser Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

Refrigerator KE T

Refrigerator KE T Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient AirFlow INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21 Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7

More information

Safe Enclosure Cooling

Safe Enclosure Cooling Safe Enclosure Cooling Heat Exchangers 2017 www.seifertsystems.com Table of Contents Page Product Overview 3 Air / water heat exchangers 4-18 Air / air heat exchangers 19-25 Thermal Management solutions

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt 763.576.32 SPEC-75 F763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS SPECTRACOOL COMPACT INDOOR N17 115/23 Volt BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527 Watt INDUSTRY STANDARDS UL/cUL Listed;

More information

DESCRIPTION. 42 mm. 125 mm

DESCRIPTION. 42 mm. 125 mm RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller

More information

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications Data Sheet 907020 Page 1/9 Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications For measuring relative humidity and temperature For versatile climatic applications and ventilation

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page How to Select and Size Enclosure Thermal Management Systems Follow the steps detailed in this white paper for optimal

More information

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. PH FX (763) 422-2600 422-2211 : CHAPTER12 Thermal Management Featured Products in this Chapter Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. 1156 Outdoor Air Conditioners T43, T50

More information

Room Temperature Sensors

Room Temperature Sensors 1 749 1749P01 QAA201 Symaro Room Temperature Sensors QAA201 Active sensors for acquiring the room temperature Operating voltage AC 24 V or DC 135 35 V Signal output DC 010 V or 420 ma Use In heating, ventilation

More information

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01 Gamma instabus Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG1 528-1DB01 Technical Product Information Universal Dimmer for switching or dimming of dimmable lamps Supports dimmable lamps including

More information

ClimaSys Resistance heaters Selection guide

ClimaSys Resistance heaters Selection guide Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC

More information

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345 External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10

More information

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB Product DELTA profil DELTA ambiente DELTA style DELTA i-system Motion detector 5WG1 255-2AB01 pearl grey 5WG1 256-2AB01 arctic white 5WG1 255-2AB11 titanium white 5WG1 258-2HB11 titanium white 5WG1 255-2AB11

More information

Thermal Management INDEX. Management. Thermal TM-1

Thermal Management INDEX. Management. Thermal TM-1 Heat builds up rapidly in enclosed environments, compromising the performance and life span of equipment. Like insurance for your electronics, effective thermal management maximizes the efficiency and

More information

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance T125-E Electric Fan Coil Thermostat Product Bulletin New Generation T125 Electric Fan Coil Thermostats are designed to control heating, cooling, or air conditioning unit in Commercial, Industrial and Residential

More information

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8000 Stationary gas detector (EC) Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic

More information

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER G-Series Cooler UPRIGHT COOLER Manual is for the following models: -N13EB G-9-N13EB -B13EB Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

Ceiling Microwave presence/absence detector 12-24V AC/DC

Ceiling Microwave presence/absence detector 12-24V AC/DC MWS3A-PRM-LV Product Guide Ceiling Microwave presence/absence detector 12-24V AC/DC Overview The MWS3A-PRM-LV Microwave presence detector provides automatic control of low voltage loads including lighting

More information

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:

More information

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics Cirrus 25/1 The Cirrus 25/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to

More information

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

19 Cabinets. Eurolan. 19 Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets Eurolan 19 Cabinets 118 19 Cabinets Eurolan 19" Floor Standing Cabinets page 120 Lamps page 190 Racknet Floor Standing Cabinets page 122 Racklan Floor Standing Cabinets page 127 Rackserv Floor Standing

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The

More information

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents) Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC

More information

SITESTAR CABINET DESCRIPTION

SITESTAR CABINET DESCRIPTION SITESTAR CABINET DESCRIPTION Product No: D000100/1 Revision: 03 SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP...5 1.2 DOCUMENTS...5

More information

LANDE SECURITY CABINETS and FIELD ENCLOSURES

LANDE SECURITY CABINETS and FIELD ENCLOSURES Front Door Type WxDxH Outer Skin Inner Skin Radius Type Corner Structure 90 Corner Structure Recessed Door Outer Closing Door Angled / Sloped Canopy Type Plain Canopy Type Crossfall Canopy Type Slotted

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

Top-Mount Air Conditioners

Top-Mount Air Conditioners Product Overview Top-Mount Air Conditioners MHB11 Model 92 92 Product Overview The perfect cooling solution when side-mount air conditioning is not an option Top-Mount Air Conditioners PRODUCT OVERVIEW

More information

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges) External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2

More information