mechreps.com SAN ANTONIO COLLEGE STATION AUSTIN CORPUS CHRISTI RIO GRANDE VALLEY
|
|
- Brice Wilkinson
- 6 years ago
- Views:
Transcription
1 SAN ANTONIO AUSTIN CORPUS CHRISTI COLLEGE STATION RIO GRANDE VALLEY
2 AIR MOVEMENT ACCUREX accurex.com Kitchen Hood Systems, Make-Up Air Equipment, Exhaust Fans, Controls, Fire Suppression Systems ACUTHERM acutherm.com Stand Alone VAV Diffusers, DDC Controlled VAV Diffusers AMPCO ampcostacks.com Positive & Negative Pressure Vent Systems BERNER INTERNATIONAL berner.com CLIMATE MASTER climatemaster.com Air Curtains, Air Doors Water Source & Geothermal Heat Pumps, Dedicated Outside Air Units DUCT DIRECT ductdirect.com ELGEN MANUFACTURING elgenmfg.com ENERGY LABS energylabs.com Spiral Duct (Round, Oval, Single Wall, Double Wall, Self- Sealing, Slip Joints) Duct Angle Flange, Corners, Gasket, Duct Sealer, Weld Pins, Turning Vane and Rail, Flexible Connectors, Damper Hardware, Strut & Hangers, Access Doors, Shrink Wrap, Collars, Spin-Ins, Conicals, Elbows, Snap-Loc Custom Air Handling Units & Energy Recovery Units, Packaged Rooftop AHU s, Data Center AHU s
3 ENTREMATIC FANS entrematicfans.com High Volume Low Speed Ceiling Fans FABRICAIR fabricair.com GREENHECK FAN CORP. greenheck.com MARKEL markel-products.com PRICE INDUSTRIES priceindustries.com REZNOR reznorhvac.com Fabric Duct Systems Roof/Wall/In-Line Fans, Vane Axial, Cabinet Fans, Utility Vent Sets, Make-Up Air Systems, Kitchen Hoods, Dampers, Louvers, Energy Recovery Units, Lab Exhaust Fans, Fan Coil Units, ARI Coils, 100% Packaged Outside Air Units, Sunshades, Equipment Enclosures, Motor Starters, Duct Heaters Electric Unit Heaters, Wall Heaters, Cabinet Heaters, Duct Heaters Grilles & Registers, Ceiling, Linear & Fire-Rated Diffusers, Terminal Units, Security Products, Underfloor Products, Displacement Ventilation Products, Sound Attenuators, Acoustic Panels, Radiant Panels, Chilled Beams, Fan Coils, Operating Room Systems, Small Building Controls, Venturi Valves Gas-Fired Heating Equipment, Infrared Heaters SEMCO semcohvac.com Spiral Duct (Round, Oval, Single Wall, Double Wall, Self- Healing, Slip Joints), Sound Attenuators, Acoustic Enclosures & Panels for Built-Up Air Handlers THERMAFLEX thermaflex.net Flexible Air Duct VTS vtsgroup.us Air Handling Units, Blower Coils, Energy Recovery ZEHNDER zehnder-rittling.com Fan Coil Systems, Water Source Heat Pumps, Low Temperature and High Temperature Cooling Systems, Hydronic Heating Systems
4 SPECIALTY AAF FLANDERS aafintl.com Commercial/Industrial Air Filtration Products, HEPA and ULPA Filters BRY-AIR bry-air.com Desiccant Dehumidifiers FIRE RATED HVAC SYSTEMS CAR-MON, INC. car-mon.com CLEAN ROOMS INTERNATIONAL cleanroomsintl.com CONQUEST FIRESPRAY conquest-firespray.com LINK-SEAL linkseal.com Vehicle & Welding Exhaust Systems Fan Powered HEPA Filters, Grid, Softwalls, Hardwalls, Clean Benches, Fan Cabinets Flamebar Fire-Rated Duct Systems Modular Pipe Penetration Seals, Sleeves MONOXIVENT monoxivent.com Fiberglass Reinforced Plastic Corrosion Composite Ducts PANASONIC business.panasonic.com/ products-hvac-hvacvrf PRICE NOISE CONTROL pricenoisecontrol.com Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems HVAC Silencers, Acoustical Panels, Acoustic Louvers
5 PURAFIL purafil.com Odor Abatement, Gaseous Filtration, Chemical Filtration, Air Monitoring THE VMC GROUP thevmcgroup.com Vibration Isolation, Flex Connectors, Expansion Joints, IBC Wind & Seismic Systems OUTDOOR DUCT SOLVED THERMADUCT thermaduct.com Outdoor Rectangular Ductwork TWIN CITY HOSE twincityhose.com Metal Braided Connectors, Rubber Expansion Joints, Flexible Metal Hose, Seismic Connectors, Externally Pressurized Expansion Joints YASKAWA yaskawa.com Variable Frequency Drives, Simplex and Multiplex Pump Control Systems (IQ Pumps), Motors CONTROL AIR MONITOR CORPORATION airmonitor.com ONICON onicon.com Airflow Measuring Stations, Probes & Pressure Sensors, Electronic Transmitters & Controllers, Room/Hood Monitors & Controllers, Electronic Control Systems HVAC Flow Meters, BTU Meters PRICE CRITICAL CONTROLS pricecriticalcontrols. com PRICE ELECTRONICS priceelectronics.ca Laboratory Controls, Vivarium Controls, Room Pressurization Controls for Operating Rooms, Isolation Rooms and Compounding Pharmacies, Room Pressurization Monitoring, Venturi Valves Building Automation Controls
6 HYDRONIC CEMLINE CORPORATION cemline.com DRI-STEEM HUMIDIFIER CO. dristeem.com Chill Water Storage Tanks, Unified Steam Generators, Steam to Water Heat Exchangers, Packaged Steam Water Heaters Electric/Gas/Steam Humidifiers, Steam Dispersion Tube Assemblies, High-Pressure Atomizing Systems, Water Treatment Systems GRUNDFOS grundfos.com Pumps, Packaged Pumping Systems, Expansion Tanks, Air Separators, Suction Guides, Triple Duty Valves KELVION kelvion.com Plate Frame Heat Exchangers, Brazed Heat Exchangers LAARS HEATING SYSTEMS laars.com PRO HYDRONIC SPECIALTIES prohydronicspecialties.com Condensing & Non-Condensing Boilers, Storage Tanks, Buffer Tanks, Water Heaters, Pool Heaters Automatic & Manual Balancing Valves, Coil Valve Packages, Water Source Hose Kits SPIROTHERM spirotherm.com Air Eliminators, Dirt Separators, Combination Air/Dirt Separators Tower Tech towertechinc.com Fiberglass Modular Cooling Towers, Concrete Cooling Towers
7 WAREHOUSE STOCK AAF FLANDERS ACUTHERM APG DUCT DIRECT DURO DYNE DWYER ELGEN MANUFACTURING GREENHECK LINK-SEAL LOCHINVAR METAL FAB MILCOR MIRO INDUSTRIES PETE S PLUGS PRICE SEMCO SHURTAPE THERMAFLEX TWIN CITY HOSE VMC/AMBER BOOTH WATTS WINKLER YASKAWA YOUNG REGULATOR Filters Thermally Powered VAV Diffusers Stainless Steel Clamps Single Wall Spiral Pipe & Accessories Flexible Connectors, Pins, Damper Hardware Magnehelic Filter Gauges, Manometers Duct Angle Flange, Corners, Gasket, Duct Sealer, Weld Pins, Turning Vane and Rail, Flexible Connectors, Damper Hardware, Strut & Hangers, Access Doors, Shrink Wrap, Collars, Spin-Ins, Conicals, Elbows, Snap-Loc Fans, Radiation Dampers, Louvers, Roof Curbs, Access Doors, Motor Starters Pipe Modular Seals Boiler Replacement Parts Fume Exhaust Flue Pipe & Accessories Sheetrock Access Doors Roofing Pipe Supports Pete s Plugs, Probes, Adapters Grilles, Registers, Diffusers, Air Terminals Single Wall Spiral Pipe & Accessories Foil Tape, Duct Tape Flexible Duct Products Flexible Pipe Connectors Vibration Isolation Pressure Relief Valves Blast Gates Variable Frequency Drives Cable Operated Dampers
8 AUSTIN CORPUS CHRISTI COLLEGE STATION SAN ANTONIO RIO GRANDE VALLEY Copyright June 2017 Mechanical Reps Inc.
AIR DISTRIBUTION DIVISION VOLUME 4
AIR DISTRIBUTION DIVISION VOLUME 4 PROVINCE OF QUEBEC PREMIUM GRILLES & DIFFUSERS Linear Diffusers & Grilles VAV Diffusers Underfloor Air Distribution Ceiling Component Diffusers Ceiling Diffusers Grilles
More informationINDUSTRIAL PRODUCTS VOLUME 4
Since 1966 Serving Southwestern Ontario. INDUSTRIAL PRODUCTS VOLUME 4 SOUTHWESTERN ONTARIO Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE
More informationBaltimore Manufacturer Line Card
Baltimore Manufacturer Line Card 12500 Baltimore Avenue, Unit F; Beltsville, MD 20705 301-918-0241 www.hbproducts.com abi Airbalance www.airbalance.com AJ Manufacturing www.ajmfg.com American Louver www.americanlouver.com
More informationSECTION DUCTWORK
SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationDOCUMENT TABLE OF CONTENTS
DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationCOHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.
23 00 00 HEATING, VENTILATING & AIR-CONDITIONING The following is the HVAC outline specifications, which defines the scope of work of the HVAC system. PART 1 GENERAL 1.1 CODES A. All work installed under
More informationMECHANICAL PRODUCTS VOLUME 9
Since 1966 Serving Southwestern Ontario MECHANICAL PRODUCTS VOLUME 9 SOUTHWESTERN ONTARIO COMMERCIAL GAS FIRED MAKE-UP AIR UNITS HVAC PRODUCTS AND SERVICES FOR THE COMMERCIAL SECTOR Gas fired make-up air
More informationAlerton Controls is a leader in developing direct digital controls with BACNET capability.
Addison is a leading supplier of HVAC cooling and dehumidification equipment for commercial and industrial applications with extensive experience in treating ventilation air. We specialize in 100% dedicated
More informationMECHANICAL PRODUCTS VOLUME 8
Since 1961 Serving the Greater Toronto Area First in Quality, First in Service. MECHANICAL PRODUCTS VOLUME 8 TORONTO LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed
More informationENGINEERED PRODUCTS LINE CARD New England, Upstate New York, Western Pennsylvania & West Virginia
ENGINEERED PRODUCTS LINE CARD New England, Upstate New York, Western Pennsylvania & West Virginia ABS, associated with innovation and well-proven solutions for wastewater handling, is a product brand of
More informationSECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...
SECTION 230001 TABLE OF CONTENTS SECTION 230001 PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS... 1 1.00 FILED SUB BID... 1 1.01 PROJECT OVERVIEW... 2 1.02 DESIGN CRITERIA... 4 1.03 CODE ISSUES...
More informationAlerton Controls is a leader in developing direct digital controls with BACNET capability.
Addison is a leading supplier of HVAC cooling and dehumidification equipment for commercial and industrial applications with extensive experience in treating ventilation air. We specialize in 100% dedicated
More informationSECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.
SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.
More informationAIR DISTRIBUTION PRODUCTS VOLUME 4
. AIR DISTRIBUTION PRODUCTS VOLUME 4 DARTMOUTH LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationManufacturers Representatives Since Industrial Systems, Inc. Computer Support, Inc
Manufacturers Representatives Since 1974 Industrial Systems, Inc. Computer Support, Inc. www.industrialsystems.org 1-800-460-0469 210-493-4200 ENGINEERED PRODUCTS FOR THE ENGINEERED ENVIRONMENT Sewage
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationHVAC 101. The Basics of Heating, Ventilation and Air Conditioning
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning HVAC Heating, Ventilation and Air Conditioning Provides comfort for people Allows humans to exist under adverse conditions. Comfort Comfort
More informationYOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS
YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS Energy International Corporation is the recognized leader in the distribution of HVAC and electromechanical products throughout the Middle East
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationAIR DISTRIBUTION PRODUCTS VOLUME 5
. AIR DISTRIBUTION PRODUCTS VOLUME 5 HAMILTON Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE SILENCERS Price offers a full line of high quality
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance
More informationAIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems
233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section
More informationAIR DISTRIBUTION PRODUCTS VOLUME 8
. AIR DISTRIBUTION PRODUCTS VOLUME 8 EDMONTON LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED
More informationHVAC 101. H V A C S y s t e m s
H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost
More informationAIR DISTRIBUTION PRODUCTS EDITION 2
. AIR DISTRIBUTION PRODUCTS EDITION 2 BARRIE SILENCER MANUFACTURING: Woodbridge, Ontario TORONTO-MADE SILENCERS PRICE SILENCERS From our full line of silencers to our revolutionary terminal / silencer
More informationAIR DISTRIBUTION PRODUCTS VOLUME 6
Since 1966 Serving Southwestern Ontario AIR DISTRIBUTION PRODUCTS VOLUME 6 SOUTHWESTERN ONTARIO LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated
More informationAppendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.
Appendix B Symbols for Drawings Table B.1 Air moving devices and ductwork symbols Air Movement Fans Axial flow fan Centrifugal fan Propeller fan Intake roof ventilator (supply) Exhaust roof ventilator
More informationDesign Standards Manual
Design Standards Manual Table of Contents: Part III (Divisions 1-32) Section No. Title Revision DIVISION 1: GENERAL REQUIREMENTS 01524 Construction Waste Management 05/07 01815 HVAC Commissioning Requirements
More informationEXHAUST FAN SCHEDULE
DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR
More informationSECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS
1.0 GENERAL SECTION 15740 SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.01 DESCRIPTION Item A. Scope This section specifies four sizes of fan coil units designed for hydronic heating and air conditioning.
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationNC State University Design and Construction Guidelines Division 23 Basic Mechanical Requirements
1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents for mechanical and plumbing systems. 2.0 General Requirements A. Warranty and Guarantee 1. Specifications
More informationINDEX OF VA STANDARD DETAILS AS OF DECEMBER 2014
DIVISION 00 SD000115-01 SD000115-02 SD000115-03 SD000115-04 SD000115-05 SD000115-06 SD000115-07 SD000115-08 SD000115-09 SD000115-10 SD000115-11 SD000115-12 SD000115-13 SD000115-14 SD000115-15 SD000115-16
More informationLARGE CAPACITY HEATERS
250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS
More informationSECTION AIR OUTLETS AND INLETS
SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationAIR DISTRIBUTION PRODUCTS VOLUME 6
Since 1961 Serving the Greater Toronto Area. AIR DISTRIBUTION PRODUCTS VOLUME 6 TORONTO Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE SILENCERS
More informationSECTION (15820) - AIR DUCT ACCESSORIES
PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors
More informationCleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY
PART I - GENERAL 1.1 SUMMARY A. This section addresses the general requirements for air handling distribution systems, including air handlers, ductwork, ductwork accessories, terminal units, air devices,
More informationSYSTEM SOLUTIONS SCHOOLS
SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade ehpricedartmouth.com SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade THEATRES 3 GYMNASIUMS 5 WOOD SHOPS 7 MECHANICAL SHOPS
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationBUILDING DESIGN STANDARDS. AIR CONDITIONING DIVISION 23 Heating, Ventilation and Air Conditioning
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationMECHANICAL PRODUCTS VOLUME 7
First in Quality, First in Service MECHANICAL PRODUCTS VOLUME 7 PROVINCE OF QUEBEC COMMERCIAL GAS FIRED MAKE-UP AIR UNITS HVAC PRODUCTS AND SERVICES FOR THE COMMERCIAL SECTOR Gas fired make-up air units
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More information21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device
DIVISION 23800 APPENDIX A ASHTABULA CAMPUS: 1. Air Handling Equipment And Appurtenances 2. Exhaust Fans 3. Fume Hood Exhaust Fans 4. Fume Hood monitoring devices and annual certification of face velocity
More informationProduct Lines
2017-2018 Product Lines Refrigeration Equipment & System Components Controls, Motors, & Electrical Components HVAC & Hydronic Equipment HVAC & Hydronic System Components Food Service Equipment Instruments
More informationAIR DISTRIBUTION PRODUCTS VOLUME 6
. AIR DISTRIBUTION PRODUCTS VOLUME 6 VANCOUVER LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options
More informationUniversity of Delaware
University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 73 00_AIR HANDLING UNITS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular custom & semi-custom built indoor air handling
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#56566/Page 1/May 23, 2017 HVAC Heating Plant The original Town Hall building and Addition building are primarily heated by a gas fired hot water plant that is located in the basement. The boiler plant
More informationAIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters
237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices
More informationSAFETY AND INSTALLATION MANUAL MODEL 8100
SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table
More informationAIR DISTRIBUTION PRODUCTS VOLUME 6
. AIR DISTRIBUTION PRODUCTS VOLUME 6 OTTAWA PRICE ELECTRONICS GENERAL OFFICE APPLICATION Rooftop Unit Controller The Price Rooftop Unit Controller (PRTU) polls data from the network zone controllers and
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous
More informationSelected Laboratory Energy Efficiency Measures
Selected Laboratory Energy Efficiency Measures These are some of the most effective energy efficiency measures for laboratories 1. Reduce (optimize) air changes per hour in lab space 2. Design to the proper
More informationAIR DISTRIBUTION PRODUCTS VOLUME 7
. AIR DISTRIBUTION PRODUCTS VOLUME 7 KELOWNA LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options
More informationPharmaceutical Facility Design
PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS
PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate
More informationAir Marketing Group 110
Air Innovations Hepair Integrated Modular Environmental Systems Horizontal 2' x 4' Single Package Vertical Single Package Units Control of Temperature, Humidity, Pressure and Cleanliness Airy Teehnolo2y
More informationBest Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation
Best Practices for Applied Rooftop ` Systems - Application and Jerry Cohen President Jacco & Assoc. Installation Who is Jacco Established 1968 Hudson, Ohio Columbus, Ohio Toledo, Ohio Systems Knowledgeable
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationQuestions??????? Thank you
Questions??????? Thank you Sustainable Design Products and Systems Dan Hahne/Eric Dowell ASP Sustainable Designs Overview Price and Uponor Hydronic Heating and Cooling Price Displacement Ventilation Price
More informationSYSTEM SOLUTIONS SCHOOLS
SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade ehpricehamilton.com ehpriceoshawa.com ehpriceottawa.com ehpricesouthwesternontario.com ehpricetoronto.com SYSTEM SOLUTIONS SCHOOLS Indoor
More informationD. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.
SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:
More informationModel UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED
Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationSECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes
Air Control and Distribution Devices Product Section Ducted devices, used to deliver air into/or remove air from a space and which provide control of air volume, direction, temperature, and/or pressure.
More informationSECTION (15833) - HVAC POWER VENTILATORS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted
More informationDIVISION 23 - HVAC HVAC Air Distribution
PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for
More informationBulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications
Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationH2O COIL. Heat Exchange and Air Movement Products Product Preview
2011 Product Preview ATQ Series Hot Water Duct Coils Meets ARI 410 Standards 1, 2 and 3 Row Hot Water Duct Coils Galvanized Steel 18 ga. frame w/1 flange Aluminum Fins,.0045 thickness. Copper Tubing, 1/2
More informationMECHANICAL SERVICES 101. Ian White
MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects
More informationArchitectural Engineering Senior Thesis Mechanical System Redesign
Saint Joseph Medical Center Architectural Engineering Senior Thesis Mechanical System Redesign Chris Nicolais Building Description Existing Mechanical System Proposed Redesign Alternative Option Emergency
More informationIndustrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation
Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating
More informationHVAC Mandatory Provisions Part II, Page 1
HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency
More informationCONTENTS. B. System Design and Performance Requirements
15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationB. System Design and Performance Requirements
15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationCopyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services
Page 238216-1 Copyright 2003 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical
More informationREFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS
*s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT
More informationDARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES
SECTION 15830 HEATING & COOLING TERMINAL UNITS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All fan coil units shall be sized to meet design load while operating at medium speed. In extreme noise sensitive
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationBest Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation
Best Practices for Applied Rooftop ` Systems, Applications and Jerry Cohen President Jacco & Assoc. Installation Established 1968 Hudson, Ohio Columbus, Ohio Toledo, Ohio Focused on the Engineered Environment
More informationDIVISION 23 - HVAC HVAC Air Distribution
PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for
More information