AIR DISTRIBUTION DIVISION VOLUME 4

Size: px
Start display at page:

Download "AIR DISTRIBUTION DIVISION VOLUME 4"

Transcription

1 AIR DISTRIBUTION DIVISION VOLUME 4 PROVINCE OF QUEBEC

2 PREMIUM GRILLES & DIFFUSERS Linear Diffusers & Grilles VAV Diffusers Underfloor Air Distribution Ceiling Component Diffusers Ceiling Diffusers Grilles and Registers Fire Rated Diffusers Security Grilles Round Floor Diffusers Linear Floor Grilles Linear Floor Heaters Underfloor Controllers Underfloor Terminal Units Underfloor Deflection Grilles Displacement Ventilation Wall Mounted Diffusers In-Wall Diffusers Free Standing Diffusers Floor Mounted Diffusers Ceiling Mounted Diffusers Linear Enclosure Diffusers Industrial Natural Ventilation Operable Wall & Penthouse NV Controller 2

3 PREMIUM GRILLES & DIFFUSERS cont d Acutherm Air Inc. Square VAV Diffusers Round VAV Diffusers Linear VAV Diffusers Pressure Control Products Temperature Control Products Fire rated door grilles Krantz Air Concepts Inc. German engineered and manufactured air distribution Specialist in premium radial and twist diffusers Directional Air Distribution Products Punkah Diffusers Nozzle Diffusers Industrial Diffusers 3

4 DAMPERS Greenheck Fire Dampers Smoke Dampers Fire/Smoke Dampers Ceiling Radiation Dampers Backdraft Dampers Control & Balancing Dampers Actuators Access Doors Dampers Smoke Fire / Smoke Manual Balancing Commercial Control Heavy Duty Industrial Fire dampers Commercial Back Draft Commercial Barometric Relief Heavy Duty Industrial Backdraft Trolec, Inc. Young Regulator Galvanized Steel (anti-corrosion treatment available) Stainless Steel Extruded Aluminum Bowden Remote Control Dampers and Controllers Damper Regulators Automatic Changeover Dampers Motorized Dampers Manual Dampers 4

5 LOUVERS Greenheck Formed Metal Extruded Standard Blade and Chevron Blade Acoustical Extruded Penthouse Formed Metal Penthouse Extruded Adjustable Thinline Wall Application Rain Storm Vision Screens Kitchen Exhaust Sand Trap Louvered Shapes Louvered Doors Sunshades Architectural Special as per request Sightproof Extruded Wind-Driven Rain Resistant Extruded Extruded with Integral Motorized Dampers TERMINAL UNITS Sand Penthouses and penthouse elevator vents Brick Vents Equipment Screens Standard, geometrical, irregular shapes or custom Trolec, Inc. Aluminium Galvanized Steel Birdscreens or Insect Screen Single Duct Terminal Units Fan Powered Terminal Units Control Valves Dual Duct Terminal Units Induction Terminals Retrofit Terminal Units Special Application Terminal Units 5

6 NOISE AND VIBRATION ISOLATION The VMC Group Commercial and custom silencers Rectangular, elbow and circular silencers Absorptive, film-lined, and packless silencers Speech privacy and cross-talk silencers Acoustic enclosures and barriers Acoustical louvers Floor Mounted Isolators Bases, Rails and Brackets Hangers Pad-Type Isolators Flexible Connectors Piping Specialities Seismic Products Floating Floors Gripple Stock available 6

7 LABORATORY, CRITICAL ENVIRONMENT & SPECIALIZED EXHAUST PRODUCTS Greenheck Fume Hoods Laboratory Furniture Air Curtain Systems Ceiling Systems Displacement Diffusers Fan Filter Units Horizontal Throw Diffusers Laminar Flow Diffusers Radial Flow Diffusers Specialized Exhaust Diffusers Return & Exhaust Grilles Laboratory Exhaust Systems Nederman Fume Extraction Arms and Fans Bench Top Flexible Extraction Arms & Fume Cabinets Filter Carts & Filter Box Mobile Fume Extractors Vehicle Exhaust Fume Extractors and Hose Reels Fume Extraction Rail Systems Electrostatic & Oil Mist Filters Magna Track Fire Station Exhaust Extractors For Rescue Vehicles 7

8 AIR-FILTRATION - STANDARD AND CRITICAL EXHAUST AAF Flanders Disposable Air Filters Air Filter Media and Auto Rolls Pleated Filters Medium and High Efficiency Rigid Type Air Filters Medium & High Efficiency Extended Surface Type Bag Filters Metal Washable Air & Grease Filters Odor Control Filters Carbon Absorbers 95% DOP and HEPA/ ULPA Filters HEPA Housings and Holding Frames ASHRAE Side Access Housings and Holding Frames Cleanroom Ceiling Filters and Hoods Gaseous / Vapor Phase Sideload and Front Load Housings CSC containment Air Filtration Systems (bagin / bag-out) ENERGY RECOVERY RegenCore alternating mass-exchanger energy recovery units with no pre-heat requirements down to outdoor temperatures of -40 C 8

9 FANS Greenheck Plastec Ventilation, Inc Fans Centrifugal Propeller Industrial Process Vane Axial Mixed Flow Gravity Ventilators Energy Recovery Products Heat Recovery Products Indoor Air Handling Units Kitchen Ventilation Systems Corrosive Resistant Polypropylene Fans & Blowers Centrifugal Fans Inline Centrifugal Fans Stainless Steel Blowers Big Ass Fans Large fans for commercial and industrial Applications Summer Cooling Winter Destratification / Heat Recirculation High volume, low speed fans 8 to 24 in diameter 9

10 CONTROLS ANALYTICS Honeywell Analytics DDC Controls Networked or Stand- Alone Controls BACnet compatible BTL certified Electronic Stand-Alone Controls Pneumatic Stand-Alone Controls Control Applications: Single Duct Controls Fan Powered Controls Hydronic Controls Bypass Controls Underfloor Controls Rooftop Controls Prodigy Smart Diffusers Commercial Gas Detection Systems Monitors, Controllers & Hand Held Products Graphical User Interface Belimo Electronic Control Valves Butterfly Valves Zone Control Valves Actuators Globe Valves Franklin Control Systems HVAC Specialty Products -Building - Automation Starters -Standard - Automation Starters Cooling Tower Controls Kitchen Hoods Controls Pump & HVAC Controls 10

11 ELECTRIC HEATING FABRIC DUCTS DuctSox Electric Duct Heaters Open or Tubular Coils MISCELLANEOUS Fabric Duct Ventilation Fabric Faced Diffusers Final Filters Underfloor Fabric Duct Unisorb Canada Sunvent Industries Specialists in Air & Gas Purification Corrosion and Odor Control Environmental Emission Control Personnel Protection Brick Vents 11

12 BOULEVARD HENRI-BOURASSA RUE DE NEMOURS AUTOROUTE 40 E.H. PRICE QUEBEC 4600 Henri-Bourassa Boul - Suite 140 Quebec, QC G1H 3A5 Ph: Fax: quebec@ehpricesales.com Website: RUE LUCIEN LALLIER RUE LOUIS B MAYER RUE LOUIS B MAYER RUE JOSEPH A BOMBARDIER DESSERTE NORD AUTOROUTE AUTOROUTE LAVAL 440 DESSERTE SUD AUTOROUTE E.H. PRICE MONTREAL 4645 Louis-B.- Mayer Laval, Quebec H7P 6G5 Ph: Fax: montreal@ehpricesales.com Website: Local Delivery Available Contact your E.H.Price Sales Representative for more information E.H. Price, a division of Lithographed in Canada 2018

AIR DISTRIBUTION PRODUCTS VOLUME 4

AIR DISTRIBUTION PRODUCTS VOLUME 4 . AIR DISTRIBUTION PRODUCTS VOLUME 4 DARTMOUTH LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options

More information

AIR DISTRIBUTION PRODUCTS VOLUME 6

AIR DISTRIBUTION PRODUCTS VOLUME 6 . AIR DISTRIBUTION PRODUCTS VOLUME 6 VANCOUVER LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options

More information

INDUSTRIAL PRODUCTS VOLUME 4

INDUSTRIAL PRODUCTS VOLUME 4 Since 1966 Serving Southwestern Ontario. INDUSTRIAL PRODUCTS VOLUME 4 SOUTHWESTERN ONTARIO Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE

More information

AIR DISTRIBUTION PRODUCTS VOLUME 5

AIR DISTRIBUTION PRODUCTS VOLUME 5 . AIR DISTRIBUTION PRODUCTS VOLUME 5 HAMILTON Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE SILENCERS Price offers a full line of high quality

More information

AIR DISTRIBUTION PRODUCTS VOLUME 6

AIR DISTRIBUTION PRODUCTS VOLUME 6 Since 1966 Serving Southwestern Ontario AIR DISTRIBUTION PRODUCTS VOLUME 6 SOUTHWESTERN ONTARIO LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated

More information

AIR DISTRIBUTION PRODUCTS VOLUME 7

AIR DISTRIBUTION PRODUCTS VOLUME 7 . AIR DISTRIBUTION PRODUCTS VOLUME 7 KELOWNA LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options

More information

AIR DISTRIBUTION PRODUCTS VOLUME 6

AIR DISTRIBUTION PRODUCTS VOLUME 6 Since 1961 Serving the Greater Toronto Area. AIR DISTRIBUTION PRODUCTS VOLUME 6 TORONTO Silencer Manufacturing: Woodbridge, Ontario TORONTO-MADE SILENCERS SMWIA-L30 YELLOW LABEL MANUFACTURING PRICE SILENCERS

More information

AIR DISTRIBUTION PRODUCTS VOLUME 8

AIR DISTRIBUTION PRODUCTS VOLUME 8 . AIR DISTRIBUTION PRODUCTS VOLUME 8 EDMONTON LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options

More information

AIR DISTRIBUTION PRODUCTS VOLUME 6

AIR DISTRIBUTION PRODUCTS VOLUME 6 . AIR DISTRIBUTION PRODUCTS VOLUME 6 OTTAWA PRICE ELECTRONICS GENERAL OFFICE APPLICATION Rooftop Unit Controller The Price Rooftop Unit Controller (PRTU) polls data from the network zone controllers and

More information

AIR DISTRIBUTION PRODUCTS EDITION 2

AIR DISTRIBUTION PRODUCTS EDITION 2 . AIR DISTRIBUTION PRODUCTS EDITION 2 BARRIE SILENCER MANUFACTURING: Woodbridge, Ontario TORONTO-MADE SILENCERS PRICE SILENCERS From our full line of silencers to our revolutionary terminal / silencer

More information

HVAC PRODUCTS VOLUME 8

HVAC PRODUCTS VOLUME 8 . HVAC PRODUCTS VOLUME 8 CALGARY LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options Analog operating

More information

AIR DISTRIBUTION PRODUCTS VOLUME 7

AIR DISTRIBUTION PRODUCTS VOLUME 7 . AIR DISTRIBUTION PRODUCTS VOLUME 7 VICTORIA LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed actuation NIST calibrated Integrated silencer and reheat coil options

More information

MECHANICAL PRODUCTS VOLUME 7

MECHANICAL PRODUCTS VOLUME 7 First in Quality, First in Service MECHANICAL PRODUCTS VOLUME 7 PROVINCE OF QUEBEC COMMERCIAL GAS FIRED MAKE-UP AIR UNITS HVAC PRODUCTS AND SERVICES FOR THE COMMERCIAL SECTOR Gas fired make-up air units

More information

AIR DISTRIBUTION PRODUCTS VOLUME 2

AIR DISTRIBUTION PRODUCTS VOLUME 2 . AIR DISTRIBUTION PRODUCTS VOLUME 2 PROVINCE OF SASKATCHEWAN PREMIUM GRILLES & DIFFUSERS Linear Diffusers & Grilles VAV Diffusers Underfloor Air Distribution Ceiling Component Diffusers Ceiling Diffusers

More information

HVAC PRODUCTS VOLUME 5

HVAC PRODUCTS VOLUME 5 . HVAC PRODUCTS VOLUME 5 THUNDER BAY AIR DISTRIBUTION PRODUCTS GRILLES, REGISTERS & DIFFUSERS Price Industries Limited www.priceindustries.com Price Industries Limited www.priceindustries.com Grilles and

More information

mechreps.com SAN ANTONIO COLLEGE STATION AUSTIN CORPUS CHRISTI RIO GRANDE VALLEY

mechreps.com SAN ANTONIO COLLEGE STATION AUSTIN CORPUS CHRISTI RIO GRANDE VALLEY SAN ANTONIO AUSTIN 210.650.9005 512.444.1835 CORPUS CHRISTI 800.650.6507 COLLEGE STATION 800.650.6507 RIO GRANDE VALLEY 956.412.1110 AIR MOVEMENT ACCUREX accurex.com Kitchen Hood Systems, Make-Up Air Equipment,

More information

SYSTEM SOLUTIONS SCHOOLS

SYSTEM SOLUTIONS SCHOOLS SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade ehpricedartmouth.com SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade THEATRES 3 GYMNASIUMS 5 WOOD SHOPS 7 MECHANICAL SHOPS

More information

MECHANICAL PRODUCTS VOLUME 9

MECHANICAL PRODUCTS VOLUME 9 Since 1966 Serving Southwestern Ontario MECHANICAL PRODUCTS VOLUME 9 SOUTHWESTERN ONTARIO COMMERCIAL GAS FIRED MAKE-UP AIR UNITS HVAC PRODUCTS AND SERVICES FOR THE COMMERCIAL SECTOR Gas fired make-up air

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS

YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS Energy International Corporation is the recognized leader in the distribution of HVAC and electromechanical products throughout the Middle East

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

SYSTEM SOLUTIONS SCHOOLS

SYSTEM SOLUTIONS SCHOOLS SYSTEM SOLUTIONS SCHOOLS Indoor Air Quality that Makes the Grade ehpricehamilton.com ehpriceoshawa.com ehpriceottawa.com ehpricesouthwesternontario.com ehpricetoronto.com SYSTEM SOLUTIONS SCHOOLS Indoor

More information

MECHANICAL PRODUCTS VOLUME 8

MECHANICAL PRODUCTS VOLUME 8 Since 1961 Serving the Greater Toronto Area First in Quality, First in Service. MECHANICAL PRODUCTS VOLUME 8 TORONTO LABORATORY SOLUTIONS Supply Venturi Valves Medium or low pressure operation High-speed

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

Sentry Air Systems, Inc.

Sentry Air Systems, Inc. Sentry Air Systems, Inc. Plastic Fume Extraction Systems Simple Solutions for Cleaner Air. Made in U.S.A. 800.799.4609 www.sentryair.com sales@sentryair.com Hazards of Plastic Fume FUME & PARTICULATE REMOVAL

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

Air Make-Up Units. Product Line Overview & Capabilities

Air Make-Up Units. Product Line Overview & Capabilities Air Make-Up Units Product Line Overview & Capabilities Air Make-Up Units Customized Solutions Unmatched Flexibility As one of the most sophisticated manufacturers of Air Make-Up Units, Aerovent s unique

More information

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW... SECTION 230001 TABLE OF CONTENTS SECTION 230001 PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS... 1 1.00 FILED SUB BID... 1 1.01 PROJECT OVERVIEW... 2 1.02 DESIGN CRITERIA... 4 1.03 CODE ISSUES...

More information

MODEL NUMBER NOMENCLATURE

MODEL NUMBER NOMENCLATURE MODEL NUMBER NOMENCLATURE DS 2200 BT P XXX OPTIONS: (SEE LIST BELOW) CONSTRUCTION: P - High Density Polyethylene FRP - Fiberglass CONFIGURATION: BT (Blow through) DT (Draw through) PA (Passive) CFM MODEL:

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Operating Performance

Operating Performance INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.

More information

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited 1 more than just a fan supplier The most diverse range of industrial fans & accessories available from a single source... 2 products oem & industrial 3 single inlet centrifugal backward curved centrifugal

More information

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain An ISO 9001 Certified Company CLEAN AIR SYSTEMS DIVISION Nan Technical Trading W.L.L P.O.Box - 2683 Manama Kingdom of Bahrain Tel: +973-17212023 Fax: +973-17212289 Email: nan@nantechgroup.com Website:

More information

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns.

More information

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

MECHANICAL SERVICES 101. Ian White

MECHANICAL SERVICES 101. Ian White MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

Displacement Ventilation

Displacement Ventilation Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

Centrifugal Fans, Non-Overloading, Backward Inclined

Centrifugal Fans, Non-Overloading, Backward Inclined BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

Performance Aire offers three VAV comfort solution packages.

Performance Aire offers three VAV comfort solution packages. The Problem Overheating or overcooling problem areas? As heating and cooling zones grow larger budget constraints cause multiple work spaces to be controlled by a single thermostat. This causes system

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser. SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:

More information

+91-9582815184 Enviro Tech Industrial Products www.envirotechindustrialproducts.net We are recognized as a leading Manufacturer, Trader, Exporter and Supplier of high quality Clean Room Equipment, Air

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.

More information

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story

More information

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.

More information

YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE

YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE ENERGY INTERNATIONAL CORPORATION CORPORATE PROFILE For more than 30 years, Energy International Corporation (EIC) has been a

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Baltimore Manufacturer Line Card

Baltimore Manufacturer Line Card Baltimore Manufacturer Line Card 12500 Baltimore Avenue, Unit F; Beltsville, MD 20705 301-918-0241 www.hbproducts.com abi Airbalance www.airbalance.com AJ Manufacturing www.ajmfg.com American Louver www.americanlouver.com

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.

More information

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

DIVISION 23 - HVAC HVAC Air Distribution

DIVISION 23 - HVAC HVAC Air Distribution PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

SECTION COOLING TOWERS

SECTION COOLING TOWERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 65 00 COOLING TOWERS SPEC WRITER NOTES: 1. DELETE BETWEEN //---// if not applicable to project. Also delete any other item or paragraph not applicable in the

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

MJC Mini. Cartridge Filter. Features. Principal specification and options

MJC Mini. Cartridge Filter. Features. Principal specification and options Cartridge Filter The MJC Mini builds on the Nederman tradition for producing robust long lasting welded filter units. Stocked as standard sub-assemblies or complete units to meet your needs for fast delivery.

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

Fan System for Drop Ceilings

Fan System for Drop Ceilings Presenting a New, Energy-Saving Fan System for Drop Ceilings * Achieve these benefits: Destratification Temperature Equalization Circulation Filtration/Purification *patent pending ZOO Fans In-Ceiling

More information

DIVISION 23 - HVAC HVAC Air Distribution

DIVISION 23 - HVAC HVAC Air Distribution PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for

More information

XPert Balance and Bulk Powder Enclosures

XPert Balance and Bulk Powder Enclosures XPert Balance and Bulk Powder Enclosures Labconco Product Diversity Glove Boxes Fume Hoods Biological Safety Cabinets Freeze Dryers Glassware Washers Filtered Enclosures Carts & Mobile Benches Centrifugal

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

2013 ASHRAE. Standards & Guidelines CD. Contents

2013 ASHRAE. Standards & Guidelines CD. Contents 2013 ASHRAE Standards & Guidelines CD Contents ANSI/ARI/ASHRAE ISO Standard 13256-1:1998 (RA 2012) Water-source heat pumps testing and rating for performance Part 1: Water-to-air and brine-to-air heat

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Glossary of Terms Laboratory & Fume Exhaust Fans

Glossary of Terms Laboratory & Fume Exhaust Fans Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model DXH Custom, packaged, roof mounted or indoor mounted unit with cooling (DX or Chilled Water) and an air-to-air aluminum flat plate exchanger designed to provide pre-cooling and reheat. The DXH is

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system. 23 00 00 HEATING, VENTILATING & AIR-CONDITIONING The following is the HVAC outline specifications, which defines the scope of work of the HVAC system. PART 1 GENERAL 1.1 CODES A. All work installed under

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

Maverick II Commercial Rooftop Systems 15 to 75 tons

Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for

More information

Mechanical System Description

Mechanical System Description 1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

Design Standards Manual

Design Standards Manual Design Standards Manual Table of Contents: Part III (Divisions 1-32) Section No. Title Revision DIVISION 1: GENERAL REQUIREMENTS 01524 Construction Waste Management 05/07 01815 HVAC Commissioning Requirements

More information

Supplying Clean Air to Industry

Supplying Clean Air to Industry Next Generation MistBuster : 500, 500 Media, 850, 2000, Infinity Supplying Clean Air to Industry The MistBuster family of self-contained mist removal systems is designed to capture mist and smoke from

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 - Superior Restaurant Services 3/21/2012 2012 - Superior Restaurant Services 2 Contents Introduction...

More information

1. Use air systems in combination with perimeter radiation. Perimeter radiation shall be capable of being operated independent of the air system.

1. Use air systems in combination with perimeter radiation. Perimeter radiation shall be capable of being operated independent of the air system. DIVISION 23 00 00 23 01 00 OPERATION AND MAINTENANCE OF HVAC SYSTEM Page 1 of 12 23 01 00 OPERATION AND MAINTENANCE OF HVAC SYSTEM 23 01 01 GENERAL REQUIREMENTS General System Design 1. Use air systems

More information