Technical Description. Climate Test Chamber. System Weiss. Type WK3-340/0. Illustration includes optional equipment
|
|
- Neal Booker
- 6 years ago
- Views:
Transcription
1 Illustration includes optional equipment Technical Description Climate Test Chamber System Weiss Type WK3-340/0
2 FACTS Operation, monitoring and documentation of the test chamber are realised by the control and programming Simpac. A 3.5 TFT colour touch screen display serves as interface between man and machine (easy, menu-guided display, no programming knowledge required). The Simpati program tool on CD ROM allows complete operation and control via a PC. An Ethernet interface for communication with a customerprovided computer system is available. Moreover, a USB-interface for recording of measuring data via USB stick is integrated and guarantees complete documentation of test runs. Monitoring and supervision possible from each workstation. Error diagnosis system and inspection system for support of maintenance and repair. The hermetic refrigeration systems work with environmentfriendly and free from chlorine refrigerants without ozonereducing potential (CFC-free). 2 stainless steel ports (50 and 125 mm Ø) are installed as standard. Central supply connections in back part of the system Large and easily accessible water tank. Integrated service information system
3 Easily accessible maintenance elements guarantee minimum service times (condenser, water tank, psychrometer). Self-cleaning humidity sensor, thus considerable increase in service life of psychrometer. High humidification performance to fulfil modern test standards Automatic water supply of humidification system with demineralised water. Contamination of humidification water is prevented. The humidity bath purging is standard. Optimum air guidance and temperature distribution better than ±1.5 K spatially guaranteed The units are designed for the performance of extreme climate values (e.g. long term tests at 85 C/85 % RH). The switch cabinet is designed in protection type IP54. Extreme installation conditions trouble-free operation can be guaranteed at ambient temperatures of up to 35 C. Extremely low noise pressure level. Low electric connected load Connection to shock-proof socket possible
4 Technical Description Technical Data WK3-340/0 Test Chamber Test chamber material Material of test space floor stainless steel, 1,4301, surface III D polished , matt surface Test area dimensions height approx. 750 mm width approx. 580 mm width between shelf supports approx. 540 mm depth approx. 765 mm Volume of test chamber Max. loading Max. loading of test chamber floor Max. load per shelf Max. load of shelf supports approx. 335 l 140 kg 60 kg distributed load 30 kg distributed load 80 kg Exterior Housing Material double-coated galvanised steel sheet Dimensions of housing height approx mm width approx. 780 mm depth approx mm Overall dimensions height 1 approx mm width 1 approx. 875 mm depth 1 approx mm Finish Door Feet two-coloured, powder coated corpus grey-white (RAL 9002) front violet-blue (RAL 5000) hinged on the left, one-hand-operation, lockable, optimum contact pressure adjustable, vibration absorbing 1 The required clearances can be reduced by dismounting components
5 Installation Drawing Stainless steel port included in basic design R1: approx. 125 mm L1: approx. 50 mm R further installation position right L further installation position left D1 1 installation position in ceiling 1. Main switch panel 2. Colour touch display 1 3. Colour touch display Condensation drain 5. Power supply cable length approx. 3.5 m 6. Door without window 8. Cooling water supply 1 9. Cooling water drain Water supply (demineralised, H 2 O) 13. Slotted port Compressed air connection 1 # Width between shelf supports $ at least 200 mm, 700 mm are required for services according to VDE standard 1 Option
6 Equipment Shelf Stainless steel ports 1 pc., stainless steel 1 pc. approx. 125 mm on right hand side 1 pc. approx. 50 mm on left hand side each one including: 1 closed silicone plug 1 slotted foam silicone plug 3.5 TFT colour touch display fixed at door front Control and programming Software digital Measuring and Control System Simpac Simpati program tool Interfaces 1 Ethernet interface for integration into network 1 USB interface for direct documentation of measuring data via USB stick (USB stick is not included in our scope of supply) or as printer interface Safety temperature limiter Specimen protection High temperature protection of humidification device Specimen switch-off Software temperature limiter high/low temperature fuse according to EN , with separate sensor, thermal safety class 2 factory-set high temperature controller potential-free contact tmin/tmax
7 Performance Data Performances for temperature tests Maximum temperature +90 C Minimum temperature -10 C, discontinuously 2) Cooling-down rate according to IEC Heating-up rate according to IEC Temperature deviation, in time, in steady state, depending on the temperature Temperature homogeneity, in space, depending on the adjusted set point value Max. heat compensation approx. 0.3 K/min., on average, measured in the air inlet approx. 1.0 K/min., on average, measured in the air inlet ±0.1 K to ±0.5 K ±0.5 K to ±1.0 K 200 W Calibration values +4 C and +90 C 2) In case of continuous, long-term operation below +5 C ice might form on the evaporator if outer humidity is allowed to enter the chamber, for instance, by open apertures, doors or if additional humidity is generated by specimens or others. In these cases, the evaporator needs to be defrosted from time to time by heating up to +10 C.
8 Performances for climate tests according to IEC Maximum temperature +90 C Minimum temperature +10 C Dew point temperature range C Temperature deviation, in time, in steady state, depending on the temperature Temperature homogeneity, in space, depending on the adjusted set point value Humidity range Humidity constancy, in steady state, depending on the climate value Calibration values Climate values according to ICH Q1A ±0.1 K to ±0.3 K ±0.5 K to ±1.0 K % RH ±1 to ±3 % RH in time +25 C / 60 % RH and +40 C / 75 % RH +25 C/40 % RH +25 C/60 % RH +30 C/35 % RH +30 C/65 % RH +40 C 25 % RH +40 C/75 % RH Humidity Diagram
9 Control and Programming Simpac Control/PLC The infotainment system comprises operation/programming and monitoring system Limit value monitoring system Diagnostic system Software Simpac control with I/O system Windows CE Embedded 3.5 TFT colour touch display for temperature and humidity for information on operating times and possible operating failures Simpati program tool for easy programming via PC (PC is not included in scope of supply) Connections/Other Power supply Mains plug 1/N/PE AC 230 V ±10 % 50 Hz, different voltages and frequencies optional shock-proof socket, 16 A, connection cable, approx. 3.5 m Protection type Test chamber IP 22 Electrical / operating panel IP 54 Noise emission as per EN Noise immunity as per EN Max. connected load Max. current consumption Average energy consumption at +40 C / 75 % RH Sound-pressure level, measured in 1.6 m height free field measurement according to EN ISO at 1 m distance in front of the system approx. 2.3 kw approx. 10 A 11 kwh/24 h approx. 46 db(a)
10 Refrigeration unit Heat dissipation to the installation room Humidification water Purge device Condensation drain Insulation Weight hermetic, air-cooled refrigeration system, CFC-free, without ozone-depleting potential, condenser air-cooled max. 1.2 kw fully-demineralised, conductivity max. 20 S/cm, ph-value 6 7, automatic supply (also possible manually), integrated reservoir with a volume of approx. 20 l consumption: at +40 C, 75 % r.h. approx. 1.5 l/24 h cyclic water exchange back-pressure-free, ¾ external thread or hose connection 12 mm free from asbestos and CFC approx. 500 kg The above mentioned output data is based on an ambient temperature of max. +25 C, 400 V/50 Hz nominal voltage, without specimen, without additional equipment and heat compensation. The admissible ambient conditions range from +10 to +35 C. The allowable relative air humidity must not exceed 75 % r.h. Subject to technical modifications.
11 Design and Functional Description Design The climate test chambers System Weiss are supplied ready for connection. Compact design means a minimum of space is required. No more assembly and commissioning on site. The machine section incorporating the refrigeration unit, water storage tank and water pump is located below the test chamber. The swing-out switch cabinet is located on the rear of the chamber. The operating elements and the main switch are located on the right hand side of the chamber. Exterior housing The exterior housing of the unit is made from lightweight corrosion-resistant, self-supporting, galvanised sheet-steel and is painted in two colours. The environmentally friendly insulation between test chamber and exterior housing guarantees best insulation values and minimum operating costs. Illustration includes optional equipment The system is delivered with adjustable, vibration absorbing feet. Test space The test space consists of a stainless-steel container and is welded vapour-tight. The test chamber is easy to clean thanks to special welding, smooth surfaces, rounded edges and embossed shelf supports. The rear test chamber wall incorporates a recirculated-air duct with builtin humidifier tub, built-in heat exchanger, electric heaters and a recirculated air fan. Air guidance via baffle plates in the test chamber floor and ceiling produces optimum ambient air and temperature distribution.
12 Test chamber door The test chamber door opens fully for easy access and is provided with high quality insulation. A perfect seal is guaranteed by special profile seals. The optimum contact pressure is ensured. An illuminated observation window is available as an option. The 3.5 TFT-colour touch panel is integrated in the test space door. Illustration includes optional equipment Stainless steel ports All sizes have two stainless steel ports, which are integrated in the left and right side walls and can be used for measuring and control wires, other supply connections or accessories. If not required, these ports are closed from the outside with thermally treated silicone plugs supplied as standard.
13 Temperature and humidity conditioning The generously dimensioned axial fan with an external drive motor draws the air out of the space. (The test chambers with a test space volume of 1000 l and 1500 l have two circulating fans each). This circulating air then flows through a fin-type heat exchanger in which it is cooled if required. Special circuits prevent any undesired formation of condensate on the heat exchanger during climatic operation and ensure the best possible temperature and humidity constancies in time. An electrical heater, installed behind the heat exchanger in air direction, heats the circulating air. The air then passes over a water bath; integrated heating and cooling elements ensure quick and precise temperature-conditioning of the water and aerosol-free humidification and dehumidification. The humidity of the test space air depends on the water temperature. The re-developed, patented climatic system enables a high relative humidity even with a heat load. Psychrometric humidity measurement The humidity of the test space air is measured according to the internationally valid psychrometric measuring principle with two resistance thermometers Pt 100 as per DIN IEC 751. Dry and wet bulb sensors are arranged next to each other in the circulating air flow. Depending on the climate the material of the wet bulb sensor is humidified. The service life increases considerably due to the self-cleaning mechanism!
14 Control system (Computer Integrated Control) Simpac is a self-monitoring, digital 32 bit measuring and control system and has been designed especially for the use in test systems. Thanks to its computing efficiency Simpac meets the requirements of process technology and facilitates the input due to the touch panel that has been especially developed by Weiss Umwelttechnik. Operation is via the colour touch display which is installed in the door or the Simpati program tool. The display provides information on the current temperature and relative humidity in the unit. Its function keys are available for direct switching on and off of testing and of the test chamber lighting. It has an alarm display and an acoustic alarm. The diagnosis system is activated on the touch screen display at the touch of a button. The software is available in German, English, French and Chinese language. Control is governed by the 32-bit I/0 system Simpac with integrated soft PLC. A web server can place test and diagnosis and maintenance information on the internet via Ethernet if desired. However, since the USB interface is routed to the outside it still presents a certain danger potential, so that, theoretically, the computer system can be jeopardised by the installation and activation of malicious programs. In order to avoid this risk potential we recommend the deactivation of the USB interface. Two customer protocols (ASCII-1, ASCII-2 and SimServe) are integrated in the test chamber. A host customer system allows the test chamber to be controlled and monitored via an Ethernet / RS 232 interface (optional) and the customer protocols. The standard climate chambers can be controlled via the ASCII-1 and ASCII-2-Basic protocols.
15 It is possible to control each test chamber extension via the ASCII-2-Dynamic and SimServe protocols. The ASCII-2-Dynamic protocol can be modified by programming the host customer system accordingly. ASCII-2-Customized (optional) Adjustment of ASCII-2 according to customer requirements or to an existing reference chamber. Remote control and monitoring (Online Service) If the unit is connected to the network, it can be reached and even controlled at almost any place in the world. To that end, network access to the file system of the unit on the intranet is sufficient or, after authorisation clearance, on the internet itself. Operation is the same on the unit or on the network and there is full access to all simulation programs and saved archives. Networking The units are compatible with the Simpati software package (as of version Simpati-4) and can be integrated into their networking environment. (Data logging operation in Simpati).
16 Simpati program tool on CD ROM for Windows (32 and 64 bit), Windows XP Prof., Windows Vista and Windows 7 (32 and 64 bit), Windows 8 Professional and Enterprise (64 bit), incl. a licence for the operation of one simulation device, operating manual and RJ45 C patch cable Cross Connect, 15 m The Simpati program tool comprises all functions for program creation and transmission into Simpac (Note: The full version of Simpati is necessary for additional functions, such as documentation). Permanently memorised overheating safety thermostat A steady state overheating safety thermostat is installed that automatically switches off the heater if the test chamber's maximum temperature range is exceeded. Any alarm is issued visually as well as acoustically. In addition, a potential-free contact is available.
17 Protection of Specimen Specimen protection via independent, adjustable temperature limiter tmin/tmax. The sensor is installed in the test space. Protection of Humidifier against Overheating The water bath of the climate test chamber is protected against overheating. Switch-off of Specimen Specimen switch-off via potential-free contact, designed specifically for heat dissipating specimen, on socket, max. load 24 V, 0.5 A. Software Temperature Limiter tmin and tmax can be set at the control panel.
18 Power Supply Each functional circuit is equipped with its own safety device, which, in the event of trouble, turns off the affected circuit or the entire chamber. The nature of the trouble is visually displayed. Wiring and electrics are governed by the latest technology and strictly conform to safety regulations for electrical installations and materials, as well as to relevant VDE regulations. Weiss Test Systems are equipped with a lockable main switch according to VDE. Technical Documentation/Operating Manual The technical documentation includes: 1 operating manual for chamber 1 operating for control unit Service manual incl. PI diagram, wiring diagram and units/parts list Declaration of conformity Calibration certificate Quality inspection certificate Print-out of control parameters
19 General Information In the constant effort to improve our product, we reserve the right to make construction or design changes without notice or obligation. The admissible ambient temperature for storage of the chamber is +55 C (+131 F). Accuracy rates are proven in the test space centre with empty test space, in steady state, without specimens, without radiation and without additional equipment in the test space. The cooling down rate stated refers to the temperature range without controlled humidity. Noise measurements and sound level data are effected as per DIN , part 1, accuracy class 2. The metallic materials used in the test device are corrosion-resistant within the temperature and climate working range indicated. If additional corrosive stress is generated by use of the test device (e.g. aggressive gases or liquids escaping the test specimen or other installations on site, corrosive specimens etc.) materials of a higher quality may have to be applied and/or additional measures may have to be taken, such as a concentration reduction by outer air purging. Depending on the corrosive stress, it might be necessary to perform additional cleaning cycles, to remove possible corrosion from the test device. We also recommend a regular maintenance of the measuring system. Please contact us. Even with perfect manufacturing and maintenance faults can still occur. These failures may cause damage of your test specimens. If you wish to avoid these (e.g. valuable specimens) please contact us so we may advise you on the necessary additional measures to be taken. 1 applies to refrigerants R 404 A and R 507; the temperature for R 134 a and R 23 is approx. +75 C (+167 F).
20 Please note that the sealing material and cable insulation used in our test units and systems contains silicone. If this is a problem for you, please contact us. The concept and design of the test units and systems manufactured and installed by WUT are in accordance with the relative, presently valid safety requirements and regulations of the ECstandards. The above regulations are adhered to when modifications or extensions are performed on site. Management System Unternehmen EG-Konformitätserklärung Weiss Umwelttechnik GmbH D Reiskirchen Greizer Str Hiermit erklären wir, dass die nachfolgend bezeichnete Maschine aufgrund ihrer Konzipierung und Bauart, sowie in der von uns in Verkehr gebrachten Ausführung den einschlägigen, grundlegenden Sicherheits- und Gesundheitsanforderung der EG-Richtlinien entspricht. Bei einer nicht mit uns abgestimmten Änderung der Maschine verliert diese Erklärung ih Gültigkeit. Die Sicherheitshinweise der mitgelieferten Produktdokumentation sind zu beachten. Dieses Dokument ist dauerhaft aufzubewahren. Unsere Auftrags-Nr / Ihre Bestell-Nr / Ihre Bestellung vom Produktbezeichnung / Typ / Geräte-Nr / Angewandte EG-Richtlinien Angewandte harmonisierte Normen Angewandte nationale Normen The EMC test and the data on the noise emission are in accordance with EN and EN A manufacturer s calibration of the temperature values is performed using DKD-calibrated measuring equipment and will be documented by a certificate. A calibration of specific temperature and humidity values can be offered if required. Angaben zum Unterzeichner Datum / Unterschrift We reserve all rights for the presentation and transmission - oral or in writing - of this quotation, in total or in parts. Any former quotations sent to you regarding this enquiry are no longer valid!
21 Scope of Supply Mat. No. Description Climate Test Chamber, System Weiss, Type complete and ready for connection, including: Digital measuring and control system Simpac 3.5 TFT colour touch display in the chamber door Simpati program tool on CD ROM for programming of control via PC Ethernet interface USB interface Self-cleaning psychrometric humidity sensor 1 stainless steel port approx. 50 mm, positioned in left side wall 1 stainless steel port approx. 125 mm, positioned in right side wall Digitally adjustable high/low temperature fuse with separate sensor 1 shelf Air-cooled refrigeration unit with environmentfriendly refrigerant Water reservoir with level indicator and automatic water supply Purging device for humidification water Adjustable, vibration absorbing feet 4 potential-free outputs 4 inputs (24 VDC) Calibration of 2 temperature and 2 climate values Technical documentation / operating manual
Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40
Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for
More informationIllustration includes optional equipment. Climate Test Chamber. System Weiss. Type WK3-600/70
Illustration includes optional equipment Climate Test Chamber System Weiss Type WK3-600/70 FACTS Operation, monitoring and documentation of the test chamber are realised by the control and programming
More informationTechnical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type
Illustration includes optional equipment Technical Description Climate Test Cabinet with increased change rates Stress Screening System Weiss Mat. No.: Type Page 1 of 20 FACTS Operation, monitoring and
More informationTechnical Description. Salt Spray Test Chamber. System Weiss. Mat. No Type SC450
Technical Description Salt Spray Test Chamber System Weiss Mat. No. 67862130 Type SC450 Page 1 of 19 Facts Control and programming via S!MCON/32*-NET. Easy operation on ergonomically positioned colour
More informationReproducible Climate...
Reproducible Climate...... the new standard in test technology Temperature and Climatic Test Chambers VT 3 & VC 3 Reliable test results... Your adviser for environmental test technology... Characteristics,
More informationA T L A S - SolarClimatic Test Cabinet SC 2000 MHG
A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for
More informationEnvironmental simulation chamber for complex alternating climate profiles
MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationCorrosion Testing... also with Climate Control
Corrosion Testing... also with Climate Control Salt Spray Test Chambers SC Corrosion Climate Alternating Test Units SC/KWT and Walk-In Salt Spray Test Chambers Weiss Umwelttechnik GmbH Simulationsanlagen
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationKMF Environmental test chamber for constant climate
SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationTEMPERATURE SHOCK TEST CHAMBERS
E SHOCK TEST CHAMBERS TEST STANDARDS VARIOUS TEST POSSIBILITIES Thanks to rapid and high-speed temperature change tests, failures on products which will undergo such extreme impacts can be detected in
More informationUMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields
UMWELTSIMULATION TEMPERATUR VARIO Walk-in chambers in modular design for multifunctional applications in different industrial fields UMWELTSIMULATION TEMPERATUR UMWELTSIMULATION TEMPERATUR With the Vario
More informationConstant climate chamber with ICH-compliant illumination
KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert
More informationConstant climate chamber with humidity
KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationPlant growth chambers
Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect
More informationConstant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:
Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationICH110. Climate Chamber. Product specification
Product specification Climate Chamber ICH110 Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More informationICH750L. Climate Chamber. Product specification
Product specification Climate Chamber ICH750L Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic
More informationConstant climate chambers
Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the
More informationICH260C. Climate Chamber. Product specification
Product specification Climate Chamber ICH260C Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More informationTESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING
FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible
More informationSunrise the beginning of a brand new day
Sunrise the beginning of a brand new day Choosing a new chamber should be easy you already know what you want. Angelantoni Industrie is now offering the most complete standard line of chambers available
More informationCompact Ultra Low Temperature Chamber
Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature
More informationConstant climate chambers
Constant climate chambers KBF ICH series Environmental simulation chambers for constant climatic conditions with light As regards compliance with standards, performance and functionality, the characteristics
More informationClimate chambers with illumination and humidity The BINDER KBWF series shines with its
KBWF series (E5.2) Climate chambers with illumination Climate chambers with illumination and humidity The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from
More informationModel KMF 115 Constant climate chambers with expanded temperature / humidity range
Model KMF 115 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification
More informationICP450. Compressor-cooled incubator. Product specification
Product specification Compressor-cooled incubator ICP450 Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage. With the help of our model selection, with dimensioned
More informationFITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER
FITOCLIMA 1.000 ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER INTEGRATED CLIMATIC AND VIBRATION FitoTerm & FitoClima temperature and humidity testing chambers
More informationBenchtop & Compact Test Chambers
MicroClimate Benchtop & Compact Test Chambers www.cszproducts.com MicroClimate Chambers These chambers are designed to provide users with a compact chamber for testing small components and products for
More informationTESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING
FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible conditions for climatic
More informationA660 Air Conditioning Laboratory Unit
A660 Air Conditioning Laboratory Unit Figure 1: A660 Base Unit shown with all options fitted High accuracy wet and dry bulb sensors before and after each process to determine air condition. All processes
More informationwww.cszindustrial.com MicroClimate Chambers Precise Temperature / Humidity Simulation in a Compact Chamber MicroClimate chambers simulate a full range of temperature and/or humidity conditions. These chambers
More informationModel KMF 720 Constant climate chambers with expanded temperature / humidity range
Model KMF 720 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification
More informationCLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental
16 ALTERNATING CLIMATE RAMP PROGRAMMING PLUS/MINUS TEMPERATURES Climatic test chamber CTC with humidity control Temperature test chamber TTC Celsius standard software Model size: 256-42 C to +190 C (without
More informationUltra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32
Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect
More informationOperating instructions
CHLORTEST Read the operating manual! The user is responsible for installation and operation related mistakes! Original operating instructions 2017 Dosing Conveying Control Liquids Gases Systems Table
More informationConstant climate chambers
Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationCorrosion Testing... also with Climate Control
Corrosion Testing... also with Climate Control Salt Spray Test Chambers SC Climate Alternating Test Units SC/KWT Corrosion Climate Alternating Test Units SC/KKWT and Walk-In Salt Spray Test Chambers Applied
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationNEW GENERATION. Efficient use of valuable space INCUBATORS
NEW GENERATION Efficient use of valuable space INCUBATORS THE NEW HETTCUBE GENERATION Now with touchscreen and more options HettCube 600 600 R HettCube 400 400 R HettCube 200 200 R 2 EVERYTHING UNDER CONTROL
More informationConstant climate chambers
Constant climate chambers KBF series Environmental simulation chambers for constant climatic conditions The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance
More informationOPERATING MANUAL RAY-NC 1000 SERIES
Release Date: 24.01.2017 FRABA GmbH 1 / 12 1. Safety Regulations Risk of personal injury and damage to property! The RAY-NC 1000 must only be installed and put into service by qualified and certified electricians
More informationModel KBF 240 Constant climate chambers with large temperature / humidity range
Model KBF 240 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure
More informationStability Testing GMP- and FDA-Compliant Reliable Solutions for the Pharmaceutical Industry
Stability Testing GMP- and FDA-Compliant Reliable Solutions for the Pharmaceutical Industry Stability Testing Rev.00 / Pág. 1 NEURTEK S.A. T. +34 943 82 00 82 info@neurtek.es www.neurtek.com Our Experience
More informationNew Generation KBF 240 series
Constant climate chambers New Generation 240 series The constant climate chamber is the expert for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its
More informationModel KBWF 240 Growth chambers with light and humidity
Model KBWF 240 Growth chambers with light and humidity The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows
More informationStability Testing according to GMP & FDA
Stability Testing according to GMP & FDA... you can be assured of that! We guarantee reliable state-of-the-art products for the pharmaceutical industry Environmental Simulation - the Basis for Quality...
More informationCorrosion Testing... also with Climate Control
Corrosion Testing... also with Climate Control Salt Spray Test Chambers SC Climate Alternating Test Units SC/KWT Corrosion Climate Alternating Test Units SC/KKWT and Walk-In Salt Spray Test Chambers Weiss
More informationULTRA.GUARD ultra low temperature freezer
UF V series 700 Ultra low temperature freezers ULTRA.GUARD ultra low temperature freezer The new BINDER ULTRA.GUARD ultra low temperature freezer ensures safe long-term storage of samples at -86 C. This
More informationENVIRONMENT FRIENDLY CLIMATIC CHAMBER
ZERO OZONE DEPLETION POTENTIAL ODP NEGLECTIBLE GLOBAL WARMING POTENTIAL GWP ENVIRONMENT FRIENDLY CLIMATIC CHAMBER KK-50 DFA TK-50 CKA KK-730 DFA TK-730 CKA Environment friendly solution for temperature
More informationTTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN
TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05
More informationPlasma Freezer with air circulation TC 516 acc. to DIN 58375
These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationRefrigerated Incubator Model and Operating Instructions
Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.
More informationStability Chambers & Rooms
www.cszindustrial.com Stability Chambers & Rooms Stability Chambers CSZ Stability chambers & rooms provide a stable, temperature and/or humidity-conditioned environment for worry-free operation with a
More informationModel KBWF 720 Growth chambers with light and humidity
Model KBWF 720 Growth chambers with light and humidity The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows
More informationModel KBF 1020 Constant climate chambers with large temperature / humidity range
Model KBF 1020 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationLabkotec Ice Detector
Labkotec Ice Detector LID 3300IP Level and flow know-how since 1964 Benefits of using Ice Detector Stops wind turbine to prevent icethrow Safety first of all! Safety device Authorities / construction licence
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationZ-Plus. Temperature/Humidity Chambers.
Z-Plus Temperature/Humidity Chambers www.cszindustrial.com Z-Plus Series Temperature/Humidity Chambers Performance You Specify Reliability You Expect Features You Want Value You Need Energy You Save Z-Plus
More informationProduct specification CO2 Incubator ICO105 Safety at all times: High-end functions for the protection of cell cultures, bacteria cultures or tissue cultures. On this page, you can find all the essential
More informationManual Isolating Barrier D461R1 (Revision 01)
D461R1 Manual Isolating Barrier D461R1 (Revision 01) Product Manual Original Instructions valid for models D461R1.11 with 1x signal input into 1x isolated signal output D461R1.12 with 1x signal input into
More informationEnvironmental Chambers
Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm
More informationFITOCLIMA 600 & 1200 STABILITY
STABILITY AND PHOTOSTABILITY TESTING FITOCLIMA 600 & 1200 STABILITY STABILITY STORAGE AND PHOTOSTABILITY TESTING CHAMBERS ICH, GMP, WHO, FDA COMPLIANT Common applications include: Pharmaceuticals Cosmetics
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationUltra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700
Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700 02 Ultra low temperature freezers for long-term storage at -86 C 03 LONG-TERM STORAGE OF SAMPLES Always the right design
More informationFITOCLIMA 600 & 1200 PHARMA
FITOCLIMA 600 & 1200 PHARMA REACH-IN CHAMBERS FOR TESTING ICH, GMP, WHO, FDA COMPLIANT FitoClima 600 PH (Stability) FitoClima 600 PLH-R (Photostability) FitoClima 1200 PH (Stability with optional double
More informationDeep Freezers. Freezers. Biomedical Refrigeration I FR / MF
Deep Freezers and Plasma Storage Freezers Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu Deep Freezers
More informationInternet. Climate rating definitions. Customer service.
Climate rating definitions Climate rating SN = Ambient temperatures of +10 C to + 32 C Climate rating N = Ambient temperatures of +16 C to + 32 C Climate rating ST = Ambient temperatures of +16 C to +
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationRadial fans Series VRE OPERATING INSTRUCTIONS
Radial fans Series VRE OPERATING INSTRUCTIONS Original operating instructions Contents: 0. Preface to the operating instructions 1. Basic safety instructions 1.1 Warning symbols 1.2 Conditions of use 1.3
More informationFITOCLIMA 600 & 1200 STABILITY
FITOCLIMA 600 & 1200 STABILITY STABILITY STORAGE AND PHOTOSTABILITY TESTING CHAMBERS ICH, GMP, WHO, FDA COMPLIANT FitoClima 600 PH (Stability) FitoClima 600 PLH-R (Photostability) FitoClima 1200 PH (Stability
More informationInstructions SCHICK ceramic - milling set
Original Instructions SCHICK ceramic - milling set SCHICK - ceramic - milling set Contents: 1. Application and use 2. General notes Caution! 3. Scope of delivery 4. Description/ Illustration of construction
More informationMINI BENCH TOP CHAMBER MODEL: MI-80-A-H
MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers
More informationSTABILITY ICH. ICH Stability Tests
STABILITY ICH ICH Stability Tests ARALAB ARALAB is a company specialized in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since
More information6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE
6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE 6 points to consider when purchasing a constant climate chamber in the pharmaceutical industry
More informationWalk in Freezer. Comfortable work environment
Temp. Range /Accuracy - (-) 40 C to (+) 60 C /± 0.1 C Temp Uniformity : ± 1 C Standard features include: Temperature uniformity ±0.1ºC Temperature gradient of 1.0ºC Max. No-waste, custom-cut wall panels
More informationDEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE
TECHNOLOGY FOR LIFE DEEP FREEZERS AND PLASMA STORAGE FREEZERS Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu
More informationZ-Plus Series Temperature/Humidity
Z-Plus Series Temperature/Humidity Performance You Specify Reliability You Expect Features You Want Value You Need Z-Plus chambers are used to test and store products by subjecting them to various temperature
More informationEnvironmental Chambers
Temperature & Chambers. Temperature & Chambers - Tabletop type. Fingerprint Development Chamber - Tabletop type. Temperature Chambers. Temperature Chambers - Tabletop type. Clean Temperature & Chambers.
More informationRemote Conditioners. RC-Series. ZPRC Series
RC-Series Remote Conditioners RC Series ZPRC Series www.cszindustrial.com Remote Conditioners Two chambers for the price of one Cincinnati Sub-Zero s dual-purpose RC-Series Remote Conditioners are designed
More informationDP 300 mobile dew point instrument
Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated
More informationExternal Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C
External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality
More information1,000W (DAP-60K: 100 W per digestion vessel)
The perfect beginner s model All the benefits at a glance Speedwave Entry Technical specifications User-friendly Quick and easy to start: the high-quality TFM TM -PTFE digestion vessels consist of only
More informationEN - english. Instructions for installation and operation. Mobile humidity meter DP 207
EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please
More informationEREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY
Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water
More informationSTABILITY. Stability Storage Chambers & Environmental Stability Rooms
STABILITY Stability Storage Chambers & Environmental Stability Rooms ARALAB ARALAB is a company specialized in designing, developing, manufacturing and servicing of environmental chambers and controlled
More informationConcentrator Bedienungsanleitung Instruction Manual Mode d emploi
Concentrator 5301 Bedienungsanleitung Instruction Manual Mode d emploi Concentrator 5301 Bedienungsanleitung...5 Instruction Manual...15 Mode d emploi...25 2 Concentrator 5301 1.2 1.1 1.9 1.8 1.7 1.5 1.6
More informationXRD XRD-1500 High-Temperature Oven. Innovation in Material Science...
XRD-1500 XRD-1500 High-Temperature Oven Innovation in Material Science... New materials science calls for refined tools that enable X-ray research in well-defined environments and under controlled temperature
More informationTHERMAL MANAGEMENT. Outdoor 3.13 to
Tecoras Outdoor.1 to.18.15 Tecoras Thermal Management Strong points TEC00087 The permanent increase ofheat dissipation in electronic components and the higher packaging density of the equipment caused
More informationGMH 285 / GMH 285-BNC
GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.
More information