XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation
|
|
- Kevin Booth
- 6 years ago
- Views:
Transcription
1 The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals. All units can be fitted with an externally adjustable thermostat. With the, you get a safe and reliable heater with a handsome appearance and state-of-the-art design. Applications Typical applications for the include: control cabinets and small enclosures storage rooms for paints and cleaners grain elevators flour mills spray booths gas plants pump houses marine and offshore oil platforms cleaning and dyeing plants Selection of Refer to the atmospheric condition table (TABLE 2) at the beginning of this catalog for detailed selection data for the temperature code. To minimize cost and physical size of the heater, select the heater with the highest temperature code that suits the environment. In TABLE 8 and TABLE 9 a check mark (3) under the temperature code indicates that the surface temperature of the heater will not exceed the coded value listed in the atmospheric conditions table (TABLE 2) at the beginning of this catalog. Construction and Installation The XP and the explosionproof convection heaters utilize CCI Thermal s unique copper free aluminum extruded convector and patented x-max terminal housing. Large convector surface area and high mass fins ensure safe and efficient low temperature heat transfer to the environment. Convectors are black anodized to resist oxidation and maximize heat transfer. Convection Heater The x-max housing can be equipped with multiple tapped conduit entries throughout its length to facilitate installation. A track and trolley system and threaded covers at each end allow easy access to internal components. All units, except the single heat sink units, have a built-in terminal block for simplified electrical connection. The units are intended for wall or floor mounting with the heater positioned vertically as shown. Dual purpose brackets for floor or wall mounting and wire guards are supplied as standard. Special Wattage and s The following table lists the maximum design wattages for the four standard heat sink lengths and configurations. If standard units listed in TABLE 8 and TABLE 9 do not suit your application, a special unit based on TABLE 10 can be supplied (check factory).
2 7.25 (184 mm) (410 mm) 25 (635 mm) (860 mm) L Figure 6 Single Unit (1) Figure 7 Double Unit (2) Figure 8 Triple Unit (3) Figure 9 Quadruple Unit (4) 8 (205 mm) 8 (205 mm) Heat Sinc Heat Sinc (97 mm) or 1.25 (32 mm) Thermostat well with sensing bulb 3.5 (89 mm) Figure 10 Side View Floor Mounting Figure 11 Side View Wall Mounting Note: All units are shown with optional thermostat kit installed. Watts TABLE 8 - Explosion-Proof - Standard Heaters Standard Voltages Part No. Class I Division 1, L Group A, B, C & D Dimension Weight Class II Division 1, 2 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø Group E, F & G Class III Division 1 Class I Division 1 Group A, B, C & D (254) 3 10 (4.5) T2D (424) 3 15 (6.8) T2D (594) 3 20 (9.1) T2D (765) 3 25 (11.3) T2D (424) 3 30 (13.6) T2D (594) 3 40 (18.1) T2D (594) 3 60 (27.2) T2D (765) 3 75 (34.0) T2D (765) (45.4) T2D CCI Thermal Technologies Inc.
3 Watts TABLE 9 - Explosion-Proof - Other Available Heaters Standard Voltages Part No. Class I Division 1, L Class I Group A, B, C & D Dimension Weight Division 1 Class II Division 1, 2 Group 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø Group E, F & G A, B, C & D Class III Division (254) (4.5) T (254) (4.5) T4A (254) (4.5) T4A (765) (11.3) T (254) (4.5) T3B (765) (22.7) T (765) (11.3) T4A (424) (6.8) T3B (765) (34.0) T (254) 3 20 (9.1) T2D (765) (45.4) T (765) (22.7) T4A (254) 3 30 (13.6) T2D (594) (18.1) T3B (424) (20.4) T3B (765) (34.0) T4A (254) 3 30 (13.6) T2D (765) 3 25 (11.3) T2D (254) 3 40 (18.1) T2D (594) (27.2) T3B (765) (22.7) T3B (765) (45.4) T4A (424) 3 45 (20.4) T2D (594) (36.3) T3B (765) (34.0) T3B (424) 3 60 (27.2) T2D (765) 3 50 (22.7) T2D (765) (45.4) T3B (594) 3 80 (36.3) T2D (765) (45.4) T2D
4 TABLE 10 - Maximum Heater Wattages Heat Sink 5 (130 mm) 12 (300 mm) 19 (470 mm) 25 (640 mm) Type Thermostats CCI Thermal offers a wide variety of explosion-proof thermostats to suit most every need. All series heaters can be fitted with integral line voltage thermostats which are available either externally adjustable or tamper-proof; factory installed or as field installed kit. Remote thermostat mounting is also available. Refer to page 23 of this catalog when selecting the appropriate thermostat for the desired application. Accessories Wire Guards and Baffles All units are equipped with wire guards. Gull wing shaped bright aluminum rear baffles are standard with units rated for T2D temperature code (shipped separately). Model Coding T2D 31 T heater model HEAT SINK QUANTITY heat Sinc length 1 = 130 mm 3 = 300 mm 4 = 470 mm 6 = 640 mm WATTAGE x 10 Temperature code T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) Heater Voltage 1 = 120V 2 = 208V 3 = 240V 7 = 480V 8 = 600V phase 1 = 1-Phase 3 = 3-Phase OPTIONS T = Thermostat R = Moisture-Resistant Design CE = ATEX Approved G = Gost Approved M = Special Mechanical E = Special Electrical Note: This nomenclature illustration is intended primarily to explain how a product part number is defined. Not all wattage, size and temperature code combinations are available please consult TABLE 9 on page 16 for availability. CCI Thermal Technologies Inc.
5 CE / ATEX Explosion-Proof Convection Heater Standard Features Suitable for the following hazardous location classification: EX II 2G Ex d IIC T3 or T4 Gb ITS 05ATEX13473 (See TABLE 11) universal support leg for wall or floor mounting high surface area black anodized heat emitter with integral tubular heating elements patented x-max housing with slide out terminal block trolley simplifies installation and servicing nickel plated wire guards on all models Watts Reference Figure (Page 15) TABLE 11 - CE/ATEX Explosion-Proof Convection Heater Specifications for T3 and T4 Units - Hazardous Location Rating Volts Phase L Dim. Approx. Weight Cataloge 399 Figure T3B T3 475 Figure T3B T3 399 Figure (424) 15 (6.8) T3B T3 436 Figure T3B T3 475 Figure T3B T3 840 Figure T3B T Figure T3B T3 840 Figure (594) 40 (18.1) T3B T3 918 Figure T3B T Figure T3B T Figure T3B T Figure T3B T Figure (594) 60 (27.2) T3B T Figure T3B T Figure T3B T3 714 Figure T4B T4 781 Figure (765) 50 (22.7) T4B T4 850 Figure T4B T Figure T3B T Figure (765) 75 (34.0) T3B T Figure T3B T Figure T3B T Figure (594) 60 (27.2) T3B T Figure T3B T Figure T3B T Figure (765) 75 (34.0) T3B T Figure T3B T Figure T3B T Figure (594) 60 (27.2) T3B T Figure T3B T Figure T3B T Figure (765) 75 (34.0) T3B T Figure T3B T Figure T3B T Figure (594) 60 (27.2) T3B T Figure T3B T Figure T3B T Figure (765) 75 (34.0) T3B T Figure T3B T3 No. T-Class
Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths
Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.
More informationXGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)
The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available
More informationExplosion-Proof Forced Air Unit Heater - XGB
Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.
More informationExplosion-Proof Forced Air Unit Heater - XGB
Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.
More informationElectric Explosion-Proof Heaters & Thermostats. Product Catalog
Electric Explosion-Proof Heaters & Thermostats Product Catalog Contents Norseman TM Electric Explosion-Proof Heaters & Thermostats... 4 Standard Features... 4 Durable Construction... 4 Simplified Wiring...
More informationElectric Explosion-Proof Heaters & Thermostats. Product Catalog
Electric Explosion-Proof Heaters & Thermostats Product Catalog Contents Norseman TM Electric Explosion-Proof Heaters & Thermostats... 4 Standard Features... 4 Durable Construction... 4 Simplified Wiring...
More informationDescription. Applications
CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW
More informationCF1 ProVector Explosion-Proof Heaters
CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationPerformance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE
763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationFE1 Explosion-Proof Electric Air Heaters
Explosion-Proof Electric Air Heaters The heater core assembly is contained in a sturdy, epoxy-coated, 14-gauge steel cabinet which also carries the motor and fan assembly. Adjustable louvers allow directional
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationPerformance Data. curus Component Recognized; File No. E IP 20
TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationXEU1. Explosion-Proof Electric Air Heater For Hazardous Locations
235730 XEU1 3k mode W ls ther m & new now a ostats vailab le! Explosion-Proof Electric Air Heater For Hazardous Locations Class I, Division 1 & 2, Groups C & D Class II, Division 1 & 2, Groups F & G Temperature
More informationHOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper
HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous
More informationProduct Catalog. Air and Space Heaters. Section C
Product Catalog Air and Space Heaters Section C Contents Fan-Forced Enclosure Heater - PH...4 Control Panel & Pump House Heater - PXFT...6 Heavy Duty Convection Heater - BX...8 Air Duct Heaters - DFF,
More informationAEU1. Explosion-Proof Electric Air Heater For Hazardous Locations
AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationFX5 Series Explosion-Proof Electric Air Heaters
FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS I. GENERAL Heatrex Explosion-proof Pipe Thread Mounted Immersion Heaters are CSA approved
More informationA guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk
More informationExplosion-proof Duct Heaters
Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest
More informationLMV Series W Low Profile - Medium Base
L LMV Series 50-150W Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G;
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationDräger Polytron 8200 CAT Detection of flammable gases and vapors
Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit
More informationEJB Custom-Built Control Panels
EJB Custom-Built Control Panels Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UL and cul approved Ex d IIB + H2 T6 Certified to
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationG Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION
G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationInstallation Instructions U-RAD-LT Electric Radiant Heaters
Installation Instructions U-RAD-LT Electric Radiant Heaters 1 PG421-2 161-058006-001 May 2016 2 U-RAD-LT Electric Radiant Heaters The Safety Alert Symbol is used to indicate a risk of personal injury.
More informationToll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater
Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications
More informationSinus Jevi (Explosion-Proof) Condens Heaters
Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important
More informationStars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)
Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:
More informationEXH Series Explosionproof Electric Air Heaters
EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG EXH explosionproof electric heaters are used: In areas made hazardous by the presence of flammable
More informationWall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls
Wall, Ceiling and Floor Heaters Commercial & Industrial Electric heating and controls Our products do more in a wide range of applications. Expect More. Introduction INDEECO offers commercial and industrial
More informationApplication. Specifications. Finish
Spec-00051 I( McLean Electronics Cooling Thermal Accessories McLean Electronics Cooling: Thermal Accessories Touch-Safe Heaters Industry Standards curus Component Recognized; File No. E150057 IP 20 CE
More informationExplosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'
Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4' Part #: EPL-EMG-48-2L-T8-D Made in the USA The Larson Electronics EPL-EMG-48-2l-T8-D Explosion Proof Emergency
More informationCable Glands DB Series: Drain, Breather Valves and Unions
DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X
More informationCode Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof
Code Master Factory Sealed Strobe Luminaires Lighting Lighting: Explosionproof Visual Signal Applications Code Master Explosionproof Strobe fixtures are designed to provide safe operation in the presence
More informationTubular Industrial Process
Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationExplosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2
Explosion Proof LED Light - Equivalent to 100-150 Watt Metal Halide - Class 1 Division 2 Part #: EPLC2-LED-150W Page: 1 Made in the USA The EPLC2-LED-150W LED hazardous area light fixture from Larson Electronics
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationSpecialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products
Description Page Camera Housing VCB series Video Camera Housings 548 VCB4 DA2W2E102 VCBA SPECIALTY PRODUCTS 547 VCB series Video Camera Housings Flameproof Zone 1 and 2-21 and 22 Gas (G) and Dust (D) Applications
More informationTOUCH-SAFE HEATERS INDUSTRY STANDARDS
763.576.3200 SPEC-00051 L763.422.2211 ACCESSORIES ENCLOSURE HEATERS ACCESSORIES ENCLOSURE HEATERS TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations
More informationExplosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.
Explosion-Proof and Fan-Forced Unit Heaters Our products do more in a wide range of applications. Expect More. Introduction/Table of Contents Indeeco offers commercial and industrial electric heating and
More informationHazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED
Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationDMV Series W For Combustible Dusts
L DMV Series 50-250W For Combustible Dusts Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl.
More informationWARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.
Cheshire, CT 064 3-699-30 (Ph) 3-699-3365 (Cust. Serv. Fax) 3-699-78 (Tech. Serv. Fax) Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations STANCHION
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More information*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts
*RENTAL* Class 1 Division 1 300 Watt Incandescent Light - Explosion Proof - Wall Mount - 120 Volts Part #: RNT-EPL-WM-300W-120V Made in the USA This unit is for rentals. Please scroll down for rental rates
More informationDräger Polytron 5720 IR Detection of carbon dioxide
Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationPILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS
PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition
More informationHUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters
Available with reversible core connection feature! HUH2 36 inch fan size model now available! Hydronic Unit Heater CRN: 0H14933.2C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com
More informationAiro Wireless Intrinsically Safe White Paper. Written By: David Schmitt
Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic
More informationOverview of Hazardous Locations as They Relate to Solenoid Valves
Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible
More information48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2
48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2 Part #: HAL-EMG-24-2L-T8-D Page: 1 Made in the USA The Larson Electronics HAL-EMG-24-2L-T8-D Hazardous Area Fluorescent
More informationApplications. Standard Materials
Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures
More informationCF1 ProVector Series. Installation, Operation, & Maintenance Instructions. Electric Convection Air Heaters for Hazardous Locations
WARNING! Read all instructions before installing or using the heater. Please adhere to instructions published in this manual. Failure to do so may be dangerous and may void certain provisions of your warranty.
More informationPILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS
3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationCR 027 PTC Fan Heater W
CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027
More informationHow Limit Switches Can Stop Machines from Going Boom
How Limit Switches Can Stop Machines from Going Boom A Honeywell White Paper Safety is one of the top criteria when selecting a limit switch for hazardous location environments. In many cases, these switches
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationHLA Series Hazardous Location Fan Forced Unit Heater
Products Company Markel Products Company Markel Products Company Markel Products Co HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C &
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationEVLPF Series Compact Fluorescent
EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence
More informationzonex enclosures hazardous locations
zonex enclosures Equipment PROTECTION hazardous locations ZONEX Enclosures An expanded offering of Hinge- and Screw-cover Enclosures for hazardous locations. ATEX directive 94/9/EC and IECEX certified
More information40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated
40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Hydronic baseboard radiators. 2. Hydronic finned-tube radiators. 3. Hydronic convectors. 1.2 SUBMITTALS A. Product Data: Include rated capacities,
More information26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE
26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationSpecification Sheet. Certificates. Features. Application. Anti-Explosive Lamp
Anti-Explosive Lamp Specification Sheet Product Introduction ALT's anti-explosive lamp can be safely used in hazardous locations such as power plants, oil and natural gas drilling stations and refineries,
More informationOPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20
OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE15 2000 Watt COD. EHSAFE20 HELIOS ELECTRIC INFRARED IRK SAFE INDUSTRY MODEL 1500 Watt (cod. EH SAFE 15) / 2000 Watt (cod. EH SAFE 20)
More informationBrasch Hazardous Location Unit Heaters
Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain
More informationINTRINSICALLY SAFE LIGHTING RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting
More informationCU-MS & AH-HW Mini-Split Series
CU-MS & A-W Mini-Split Series Explosion Proof Mini-Split Air Conditioning System azardous Location N.E.C. and I.E.C. Approved 60 ertz Models : 12,000-36,000 /R General Purpose, Division I/II 50 ertz, igh
More informationRefer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program
TABLE OF CONTENTS Table of Contents Page I. Design Benefits A. Application, Design, Construction Overview... 3 B. Unit Features Horizontal Delivery Unit Heaters... 4 C. Unit Features Vertical Delivery
More informationHazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs
Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationCR1 Series Triton Corrosion Resistant Washdown Heaters
CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationINSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada
More informationDräger Polytron 8720 IR Detection of carbon dioxide
Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance
More information208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC
208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationS1L Series: Metal Bottom
S1L Series: Metal Bottom Product Features and Benefits Long life element: Patented PTC heater element lasts longer than conventional heaters Will not burn out if run in air Will not burn out due to scale
More information