Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products
|
|
- Tyrone Bradford
- 5 years ago
- Views:
Transcription
1 Description Page Camera Housing VCB series Video Camera Housings 548 VCB4 DA2W2E102 VCBA SPECIALTY PRODUCTS 547
2 VCB series Video Camera Housings Flameproof Zone 1 and 2-21 and 22 Gas (G) and Dust (D) Applications Flameproof housing to encase video camera used for onshore and offshore site and process supervision. Features Compatible with any camera model with the following specifications: Length compatible with one of the two sizes: 475 mm 735 mm Maximum cross section for the camera : < 127 cm 2. Capacitor s residual energy (after opening) : < 20 μj. Maximum dissipated power: 14 W. Equipped with back plate. Two M20 threaded cable entries. Standard Materials Body: gray painted aluminium Window: sealed toughened glass ATEX Certifications and Compliances Certification Type: CAM Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: II 2 G Type of Protection: Ex d IIC Temperature class: T6 for Ta +40 C and T5 for +55 C Dust: Zones 21 and 22 Conforming to ATEX 94/9/CE: II 2 D Type of Protection: Ex td A21 Surface Temperature: T100 C Ambient Temperature: -40 C to +55 C Index of Protection according EN/IEC 60529: IP66 Impact Resistance (shock): IK10 Internal Volume: 2 dm 3 2 liters CE Declaration of Conformity: ATEX Certificate: LCIE 03 ATEX 6080 Dimensions in Millimeters VCB4 (475 mm length version) 475 for VCM4 735 for VCM7 2 x M8 225 Length (mm) Weight kg Volume dm 3 Catalog Number VCB4 CAMERA HOUSING VCB7 548
3 VCB series Video Camera Housings Flameproof Zone 1 and 2-21 and 22 Gas (G) and Dust (D) Applications Flameproof housing to encase video camera used for onshore and offshore site and process supervision. Features Maximum dissipated power: 10 W. Equipped with a back plate. One open view glass window, usable Ø 84 mm. Two internal grounding connection: M4 screw. External grounding: M6 screw. Two M20 threaded entries at the bottom. Standard Materials Body: gray painted aluminium Window: sealed toughened glass ATEX Certifications and Compliances Certification Type: BR2d Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: II 2 G Type of Protection: Ex d IIC Temperature Class: T6 Dust: Zone 21 and 22 Conforming to ATEX 94/9/CE: II 2 D Type of Protection: Ex td A21 Surface Temperature: T80 C Ambient Temperature: -40 C to +55 C Index of Protection according EN/IEC 60529: IP66 Impact Resistance (shock): IK09 Internal Volume: 2 dm 3 2 liters CE Declaration of Conformity: ATEX Certificate: LCIE 03 ATEX 6062 Dimensions in Millimeters (Inches) 144 (5.67) 200 (7.87) 15 (0.59) 144 (5.67) 175 (6.89) 150 (5.91) Ø 67 (2.64) Weight kg Volume dm 3 Catalog Number DA2W2E102 Accessories Description Adjustable Mount Catalog Number VCBHBA CAMERA HOUSING 549
4 VCB series Video Camera Housings Flameproof Zone 1 and 2-21 and 22 Gas (G) and Dust (D) Applications Flameproof housing to encase video camera used for onshore and offshore site and process supervision. Features Maximum Power: 10 W. One open view glass window, usable diameter 155 mm. Threaded flameproof joint. Two M20 threaded entries with one blanking plug. Standard Materials Body: gray painted aluminium Window: sealed toughened glass ATEX Certifications and Compliances Certification Type: PJ70 Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: II 2 G Type of Protection: Ex d IIC Temperature Class: T6 Dust: Zone 21 and 22 Conforming to ATEX 94/9/CE: II 2 D Type of Protection: Ex td A21 Surface Temperature: T80 C Ambient Temperature: -40 C to +55 C Index of Protection according EN/IEC 60529: IP66 Impact Resistance (shock): IK10 Internal Volume: 2 dm 3 2 liters CE Declaration of Conformity: ATEX Certificate: LCIE 02 ATEX 6227 Dimensions in Millimeters (Inches) 405 (15.94) 10 (0.39) 334 (13.15) Ø 120 (4.72) 3 x Ø 10.5 (0.41) (6.54) Ø 150 (5.91) Weight kg Volume dm 3 Catalog Number CAMERA HOUSING 8 27 VCBA 550
5 Notes 551
6 Notes 552
Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationCable Glands DB Series: Drain, Breather Valves and Unions
DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion
More informationXB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation
The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.
More informationMain switch current K: with main switch (optional)
Control Boxes, Boxes and Other Components BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 in Zone 21 and Zone
More informationConvection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths
Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationINSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER
INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationA guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationEquipment and Solutions
Equipment and Solutions Solution [formally technor atex] Subject to errors or changes Editing completed January 2016 Ex-tech Group is located at Forus in Stavanger, Norway, one of the world s top Centers
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0
More informationSafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending
SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationEasy installation Certified for zones 1 and 21 High IP degree of protection
Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control
More informationFan Heaters Type VLEx
Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids
More informationSafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications
SafeSite LED Area Light - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 5 year warranty L70
More informationPerformance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE
763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationHigh bay LED lighting fixture
Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for
More informationTBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with
More informationIndustrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version
heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationSAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series
Pag. 1/6 Enclosure for asynchronous electric motors Series LEX 80,90,100,112,132,160,180,200,225,250,280,315 and 355 Ex na, Ex td execution II 3G, II 2D SAFETY INSTRUCTIONS euromotori motori elettrici
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationSwitches & Sensors FOR VALVES & ACTUATORS
SWITCHES.CROUZET.COM 1 VALVES AND ACTUATORS SWITCHES AND POSITION SENSORS Switches & Sensors FOR VALVES & ACTUATORS switches.crouzet.com SWITCHES.CROUZET.COM SWITCHES-CROUZET.COM 2 VALVES AND ACTUATORS
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationXLFE-4/1. Borosilicate glass globe
XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal
More informationMultipoint temperature sensor
Multipoint temperature sensor ATEX e / t for use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel B 903530.0.0
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationCOMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)
COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the
More informationBulletin 855T 70 mm Control Tower Stack Lights
Bulletin 855T 70 mm Control Tower Stack Lights Light Modules Red Flashing Incandescent (Black Housing) 855T B 10 FN 4 a b c d a b c d Housing Color Voltage Light Module Type Lens Color Code Description
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationMagnetostrictive sensor For bypass level indicators Model BLM
Level Magnetostrictive sensor For bypass level indicators Model BLM KSR data sheet LM 10.05 for further approvals see page 2 and 3 Applications Sensor for the continuous level measurement of liquids in
More informationFINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,
FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A
More informationEVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation
EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED
More information(German speaking trainers with English written slides)
Kiwa organizes dedicated training courses in Germany (Hannover, Kaufbeuren) especially for German manufacturers and at Kiwa in Apeldoorn, The Netherlands. Language spoken is German and English (German
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationFinned Tube Air Heaters Type WD/GG (RVS)
Finned Tube Air Heaters Type WD/GG (RVS) Our WD-H finned-tube heaters are designed for industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. The
More informationOPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER
OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER 1 1.0 GENERAL 1.1 All work should be carried out by suitable qualified personnel. 1.2 Heaters must be handled
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExTS110D Flameproof Sontel 1) Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationPROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC
PROCESS AUTOMATION Instruction manual Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC With regard to the supply of products, the current issue of the following document is applicable: The General
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationSERIES 47K GAS SENSOR
Data Sheet SERIES 47K GAS SENSOR Remote Combustible Gas Detection Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Series 47K Gas Sensor Remote Combustible Gas Detection MSA remote
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationManual for QX0201 Push Button
Manual for QX0201 Push Button Purpose of this Instruction Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationRosemount 752 Fieldbus Remote Indicator
Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationOperating Manual Distribution box
Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution
More informationATEX - ATmosphere EXplosive
ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel
More informationTRASCO ATEX Couplings
TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral
More informationPerformance Data. curus Component Recognized; File No. E IP 20
TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with
More information1510 Side Mounted Level Switch
1510 Side Mounted Level Switch General Instructions The SOR 1510 Level Switch mounts into the side of a vessel. Electric switching action is provided by the float moving a magnet into the field of a hermetically
More informationCenturion Guided Radar HAWK CGR SERIES
Safety Instructions CGR (Cat 3GD) Centurion Guided Radar HAWK CGR SERIES ATEX Category 3GD Intrinsically Safe probe / Flameproof enclosure II 3G Ex ia/d IIC T6 T2 Gc II 3D Ex ia tb IIIC T85 C T255 C Dc
More informationSpecification Sheet. Certificates. Features. Application. Anti-Explosive Lamp
Anti-Explosive Lamp Specification Sheet Product Introduction ALT's anti-explosive lamp can be safely used in hazardous locations such as power plants, oil and natural gas drilling stations and refineries,
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationANNEX GD-CERT-EX-EN SIT
SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral
More informationApplication. Specifications. Finish
Spec-00051 I( McLean Electronics Cooling Thermal Accessories McLean Electronics Cooling: Thermal Accessories Touch-Safe Heaters Industry Standards curus Component Recognized; File No. E150057 IP 20 CE
More informationATEX DELVALLE GENERAL CATALOGUE FLEXIBLE SOLUTIONS FOR HAZARDOUS AREAS UNDER ATEX & IECEX DIRECTIVES.
ATEX DELVALLE GENERAL CATALOGUE FLEXIBLE SOLUTIONS FOR HAZARDOUS AREAS UNDER ATEX & IECEX DIRECTIVES 3.18 With over 45 years of experience in design, manufacture and supply of electrical high quality Atex
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationRod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids
Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks
More informationHEAT. Industrial Ltd. Standard Products
HEAT Industrial Ltd Standard Products EXHEAT Standard Products EXHEAT Industrial Division offers fast track solutions to industry's wide and varied requirements for electrical heating systems. All heaters
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationUncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems for Use in Hazardous Locations - Directive
More informationOnly for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern
ISO 9001:2000 / ATEX 0158 II 1 GD IIB T135 C (T4) Broad beam optical fibre QW-..-1GD ATEX certificated for Ex zones 0, 1, 2, 20, 21, 22 Applicable for width deviation measurement, detection of small objects
More informationCOMPACT FLAME CONTROLLER CFC 1000
COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P
ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions
More informationGUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet
Ex d GUB Screw-on lid - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66 Polyester coating Cast mounting feet GUB-05 with lever on lid External earth screw in body Safety
More information5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05
Explosion proof Non-contact Safety Switches Explosion proof reed non-contact switches monitor the status of guarding doors in petro-chemical and food applications with explosive atmospheres. Based on reed
More informationSPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications
ZONE 1 ZONE 2 INDUSTRIAL SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ATEX and IEC Ex approved Zone 1 Zone 2 variant also available Ultra long life LED High lumen output LED Easy installation,
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationOPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20
OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE15 2000 Watt COD. EHSAFE20 HELIOS ELECTRIC INFRARED IRK SAFE INDUSTRY MODEL 1500 Watt (cod. EH SAFE 15) / 2000 Watt (cod. EH SAFE 20)
More informationTelephony & Communication
Telephony & Communication Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d installation Contrôle commande for Industry and Hazardous Product at a Glance Telephone I Mobile phone
More informationInstallation and Operating Instruction
Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex (i) 9893 0.00 GB Technical changes reserved! 0 Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex
More informationPhoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.
Phoenix Flameproof Pan & Tilt heads and Camera Housings for potentially explosive environments www.vanderbiltindustries.com Video monitoring under extreme conditions Security Products from Vanderbilt is
More informationTEM-EX-B. Figure: TEM-EX-B with PROMOS connector. ka055100en; Rev. 1.8
TEM-EX-B Figure: TEM-EX-B with PROMOS connector Robust and safe device for continuous monitoring of a temperature gradient and a temperature limit (e.g. for conveyor belt monitoring) Corresponds to the
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More information