1 Control Boxes, Boxes and Other Components BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 in Zone 21 and Zone 22 Flameproof enclosure (Ex d IIB) Main switch and distribution switch are operated with external handle. Internal termination is finished. Weidumuller SAK EN series terminals are supplied. Entries plugged. Cable glands on request (see P7/17~25). Special requirements on request. Catalogue number logic BX M(D) 81- / / / Main switch current K: with main switch (optional) current number Design No. M: illumination D: power Explosion-proof distribution boxes Zones 1&2; 21&22 /10

2 Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Technical data Explosion-proof illumination distribution boxes Explosion protection Gas explosion protection Dust explosion protection Certificates For gas explosion protection For dust explosion protection Conformity to standards General power supply circuit current Exposed fastener Enclosure material Enclosure color Built-in components Main switch switch Terminal Indicator Degree of protection Ambient temperature Cable entries Cable gland(optional) Entry direction Mounting II 2G Ex d IIB T Ex td A21 IP5 T85 BXM81- / / LCIE 10 ATEX PCEC (China) PCEC (China) EN :200; EN :2004 IEC :2004; IEC :200; IEC :2004; IEC :2004 Rated voltage: max. 415V AC 50/0Hz; Rated current: max. 100A 1A, 2A, 4A, A, 10A, 1A,20A, 25A, 2A Stainless steel Copper-free aluminium; powder coated external surface Grey Mini circuit breaker (MCB) or moulded case circuit breaker (MCCB) Note: electrical leakage protection on request Mini circuit breaker (MCB) Note: electrical leakage protection on request Weidmuller SAK EN series Red, green, yellow IP Standard M x 1.5 plug (see the selection table on P/10) DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/ Bottom Surface type (standard) Pedestal type (optional) Electric schematic diagram Circuit 1 Circuit 2 Circuit Circuit N BXM81 Series explosion-proof illumination distribution boxes /11

3 Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Selection table of BXM81- / series explosion-proof illumination distribution boxes Description Type Main Indicator Terminal Cable entries switch number switch current number BXM81-4/ /k/ BXM81-/ /k/ BXM81-8/ /k/ BXM81-10/ /k/ BXM81-12/ /k/ BXM81-4/ BXM81-/ BXM81-8/ BXM81-10/ BXM81-12/ MCB or MCCB Current: max. 100A MCB 1 P/2 P MCB 1 P/2 P 1A 2A 4A A 10A 1A 20A 25A 2A On request 1A 2A 4A A 10A 1A 20A 25A 2A On request x SAK5EN1N1PE 4 x SAK4EN4N4PE x SAK5EN1N1PE x SAK4ENNPE x SAK5EN1N1PE 8 x SAK4EN8N8PE x SAK5EN1N1PE 10 x SAK4EN10N10PE x SAK5EN1N1PE 12 x SAK4EN12N12PE x SAK5EN1N1PE 4 x SAK4EN4N4PE x SAK5EN1N1PE x SAK4ENNPE x SAK5EN1N1PE 8 x SAK4EN8N8PE x SAK5EN1N1PE 10 x SAK4EN10N10PE x SAK5EN1N1PE 12 x SAK4EN12N12PE 4 x M25 x 1.5 x M25 x x M25 x x M25 x x M25 x x M25 x 1.5 x M25 x x M25 x x M25 x x M25 x 1.5 Note 1. Please specify the number and size of cable entries and sides of the enclosure to be fitted. 2. Single line drawing (SLD) shall be provided by user. Photocell, timer, AC contactor, thermal relay or others on request.. Please specify mounting type when ordering. 4. Rainproof canopy on request. /12

4 Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Technical data Explosion-proof power distribution boxes BXD81- / Explosion protection Gas explosion protection Dust explosion protection Certificates For gas explosion protection For dust explosion protection Conformity to standards General power supply circuit current Exposed fastener Enclosure material Enclosure color Built-in components Main switch switch Terminal Indicator Degree of protection Ambient temperature Cable entries Cable gland(optional) Entry direction Mounting II 2G Ex d IIB T Ex td A21 IP5 T85 LCIE 10 ATEX PCEC (China) PCEC (China) EN :200; EN :2004 IEC :2004; IEC :200; IEC :2004; IEC :2004 Rated voltage: max. 415V AC 50/0Hz; Rated current: max. 250A 1A, 2A, 4A, A, 10A, 1A, 20A, 25A, 2A, 40A, 50A, A Stainless steel Copper-free aluminium; powder coated external surface Grey Mini circuit breaker (MCB) or moulded case circuit breaker (MCCB) Note: electrical leakage protection on request Mini circuit breaker (MCB) Note: electrical leakage protection on request Weidmuller SAK EN series Red, green, yellow IP Standard M x 1.5 plug (see the selection table on P/12) DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/ Bottom Surface type (standard) Pedestal type (optional) Electric schematic diagram Circuit 1 Circuit 2 Circuit Circuit N BXD81 Series explosion-proof power distribution boxes /1

5 Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Selection table of BXD81- / series explosion-proof power distribution boxes Description Type Main Indicator Terminal Cable entries switch number switch current number BXD81-4/ /k/ BXD81-/ /k/ BXD81-8/ /k/ BXD81-10/ /k/ BXD81-12/ /k/ BXD81-4/ BXD81-/ BXD81-8/ BXD81-10/ BXD81-12/ MCB or MCCB Current: max. 250A MCB P MCB P 1A 2A 4A A 10A 1A 20A 25A 2A 40A 50A A On request 1A 2A 4A A 10A 1A 20A 25A 2A 40A 50A A On request x SAK70/5EN1N1PE 12 x SAK10EN4N4PE x SAK70/5EN1N1PE 18 x SAK10ENNPE x SAK70/5EN1N1PE 24 x SAK10EN8N8PE x SAK70/5EN1N1PE 0 x SAK10EN10N10PE x SAK70/5EN1N1PE x SAK10EN12N12PE x SAK70/5EN1N1PE 12 x SAK10EN4N4PE x SAK70/5EN1N1PE 18 x SAK10ENNPE x SAK70/5EN1N1PE 24 x SAK10EN8N8PE x SAK70/5EN1N1PE 0 x SAK10EN10N10PE x SAK70/5EN1N1PE x SAK10EN12N12PE 4 x M25 x 1.5 x M25 x x M25 x x M25 x x M25 x x M25 x 1.5 x M25 x x M25 x x M25 x x M25 x 1.5 Note 1. Please specify the number and size of cable entries and sides of the enclosure to be fitted. 2. Single line drawing (SLD) shall be provided by user. Photocell, timer, AC contactor, thermal relay or others on request.. Please specify mounting type when ordering. 4. Rainproof canopy on request. /14

6 Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration BXM81-4/ /K BXM81-/ /K BXM81-8/ /K BXM81-10/ /K BXM81-12/ /K /15

7 Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration BXD81-4/ /K BXD81-/ /K BXD81-8/ /K BXD81-10/ /K BXD81-12/ /K /1

8 Explosion-proof Boxes BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration Pedestal type Surface type /17

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion

More information

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products Description Page Camera Housing VCB series Video Camera Housings 548 VCB4 DA2W2E102 VCBA SPECIALTY PRODUCTS 547 VCB series Video Camera Housings Flameproof Zone 1 and 2-21 and 22 Gas (G) and Dust (D) Applications

More information

ATEX certificate. Item Model Product Ex-mark/ Date of issue Remark LCIE certificate. Ⅱ2 G Ex dⅡc T6 Gb Ⅱ2 G Ex eqⅡc Gb

ATEX certificate. Item Model Product Ex-mark/ Date of issue Remark LCIE certificate. Ⅱ2 G Ex dⅡc T6 Gb Ⅱ2 G Ex eqⅡc Gb LCIE certificate 1 BAY51-Q 2 BAY51-QJ 3 BZX-6 4 YK36/18DF- 2CS 5 BY-2 6 BAY51 7 BAY51-J 8 BAY51-LED 9 BAY-H 10 BnY81 Explosion-proof light fittings Explosion-proof emergency light fittings for fluorescent

More information

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005 OPTA-PERIPH 8 Av. de Bretteville 92 200 Neuilly - France 33(0)6 85 43 82 78 - Fax : 33(0)6 07 18 28 07 User: AIR CONDITIONER ATEX CE II 3G Supplier : OPTA-PERIF Ref : Q/N 0510278 Rev.: 0 Document: IM 050312

More information

Manual for QX0201 Push Button

Manual for QX0201 Push Button Manual for QX0201 Push Button Purpose of this Instruction Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0

More information

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT Product Overview The HF9101-V1 is an electronic thermostat designed to give energy-efficient frost protection to pipe work where thermal insulation alone cannot protect pipes from freezing or being damaged

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

Fan Heaters Type VLEx

Fan Heaters Type VLEx Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

Operating Manual Distribution box

Operating Manual Distribution box Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

Exp, pressurized systems

Exp, pressurized systems Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the

More information

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC By: Helge Knudsen, Test&Approval, Niros Telecommunication A/S You may have heard those expressions concerning Transceivers and other electric equipment

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ZONE 1 ZONE 2 INDUSTRIAL SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ATEX and IEC Ex approved Zone 1 Zone 2 variant also available Ultra long life LED High lumen output LED Easy installation,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0039U issue No.:1

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 Product Technical Sheet 18, 36 and 58W single-lamp versions ST.0914.I Summary Application field 3 Structural characteristics 4 Electrical characteristics

More information

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60 www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage

More information

Explosion Protected Panelboards D2Z Series

Explosion Protected Panelboards D2Z Series Eplosion Protected Panelboards D2Z Series Installation & Maintenance Information IF 1416 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE APPLICATION The D2Z Series panelboards provide a centrally controlled

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Cable Glands DB Series: Drain, Breather Valves and Unions

Cable Glands DB Series: Drain, Breather Valves and Unions DB Series: Drain, Breather Valves and Unions 093498 Bleed Valve 093486 Combination Drain and Breather Compliance Data: ATEX Zone 1 & 2 21 & 22 ATEX II 2 GD Ex e II IP 66 CEC NEC Class 1 Zone 1 NEMA 4X

More information

Dust Explosion Protection Consistent with North American Practice

Dust Explosion Protection Consistent with North American Practice Legislation, Standards and Technology Dust Explosion Protection Consistent with North American Practice now to EN 61241-1 as an option by Helmut Greiner Figure 1: ADM Grain Mill in Kansas City, USA after

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,

More information

Easy installation Certified for zones 1 and 21 High IP degree of protection

Easy installation Certified for zones 1 and 21 High IP degree of protection Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control

More information

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure. Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

Certificate of Compliance

Certificate of Compliance FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit NexLED Ex e LED BULKHEAD 62 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Explosion Proof Combination Signal db (A) / 5 Joule

Explosion Proof Combination Signal db (A) / 5 Joule Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width) SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

PANELBOARD PROTECTION ON A GLOBAL SCALE

PANELBOARD PROTECTION ON A GLOBAL SCALE PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

High bay LED lighting fixture

High bay LED lighting fixture Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit 16-18 Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact:

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments. Phoenix Flameproof Pan & Tilt heads and Camera Housings for potentially explosive environments www.vanderbiltindustries.com Video monitoring under extreme conditions Security Products from Vanderbilt is

More information

Electrical Installations Design, Selection, Erection and Inspection

Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,

More information

Hazardous Area Zirconia Oxygen Systems

Hazardous Area Zirconia Oxygen Systems Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation

More information

Vortex Enclosure Coolers A/C ATEX

Vortex Enclosure Coolers A/C ATEX CONTENTS 1 Vortex Enclosure Coolers A/C ATEX Contents 1 Vortex Enclosure Coolers A/C ATEX 2 1.1 Overview........................................ 2 1.2 Features........................................ 2

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB Air Sensor SAC Ex FCS Ex Manual AQ M-Tech AB ATEX Air Sensor SAC Ex FCS Ex ATEX Certified AQ M-Tech AB Manual version 2.2 February 2017 2 Air Sensor Manual for SAC Ex and FCS Ex Table of contents 1. Manufacturer

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN

More information

Installation Guide SmartRadar FlexLine

Installation Guide SmartRadar FlexLine Contact Information: Head Office - Delft, The Netherlands Honeywell Enraf Delftechpark 39, 2628 XJ Delft PO Box 812, 2600 AV Delft The Netherlands Tel.: +31 (0)15 2701 100 Fax: +31 (0)15 2701 111 E-mail:

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series Pag. 1/6 Enclosure for asynchronous electric motors Series LEX 80,90,100,112,132,160,180,200,225,250,280,315 and 355 Ex na, Ex td execution II 3G, II 2D SAFETY INSTRUCTIONS euromotori motori elettrici

More information

Multipoint temperature sensor

Multipoint temperature sensor Multipoint temperature sensor ATEX e / t for use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel B 903530.0.0

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor www.static-control.in 1 Basic of Static Electricity The Generation of Static Electricity and build of its charge is present

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

GENERAL SPECIFICATION ELECTRICAL

GENERAL SPECIFICATION ELECTRICAL GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5

More information