Underfloor distributors

Size: px
Start display at page:

Download "Underfloor distributors"

Transcription

1 YOUR WISHES ARE OUR BENCHMARK Underfloor distributors Catalogue 02

2 Table of Contents PIAZZA Introduction Overview PIAZZA PIAZZA 540 PIAZZA 700 PIAZZA 1000 Pages 4-7 Page 3 Page 4 Page 5 Page 6 Page 7 PIAZZA Practical examples Installation instructions Pages 8-11 Pages 8-10 Page 11 CAMPETTO Overview CAMPETTO CAMPETTO V CAMPETTO VI CAMPETTO VII CAMPETTO VIII Pages Page 12 Page 13 Page 14 Page 15 Page 16 CAMPETTO Practical examples Installation instructions Pages Pages Page 20 PICCOLINO / RETRANT PICCOLINO RETRANT Practical examples Pages Page 21 Page 22 Page 23 2 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

3 Introduction Underfloor distributors virtually invisible - always within reach The structure of an underfloor distributor Thanks to our underfloor distributors, electrical power is quickly available anywhere and without time-consuming installation work! As with all of our products, we attach great importance to high-quality components and manufacturing. Only solid rubber distributors made in-house, with their outstanding material properties, are used. The benefits for you Power available at any time and quickly Ready for use immediately Can be walked or driven over during operation No power cables lying around, no danger of tripping Covers can be individually filled / paved Lockable in the contacted area Gas springs for force-free, automatic opening Frost-proof operation thanks to cover heating Flooding-resistant on request Maintenance-free solid rubber distributor system for electricity, water, compressed air and data connections, fittings as per the client's wishes Our services Personalised, professional advice, including on site Tried-and-tested product range Tailored, customised solutions Production of single and large series Long spare parts availability Cable opening (for closed operation) Flexible connecting cable Electric supply line Outlet for drainage Built in accordance with: BGA V1 and BGA V3 VDE 0100 Part 410 and 540 VDE 0660 Part 500 VDE 0660 Part depending on design VDE 0471 Power distributor Gas spring Connecting set Earthing plugs The right choice The following questions need to be answered in order to choose the right underfloor distributor: 1. What power connections are wanted? The size of the solid rubber distributor is defined by the socket occupancy and type of fuses used. The distributor is mounted on the cover of the underfloor distributor. The size of the power distribution also defines the junction box. We will be happy to provide more detailed information and explanations. 2. Where will the underfloor distributor be installed? Information regarding internal or external installation, along with how it will be used, is useful for ensuring the best possible design. 3. Does the underfloor distributor need to be able to withstand traffic? Your underfloor distributor is designed specifically for your needs. The higher the weight, the stronger the underfloor distributor and the foundations need to be. 4. Do you want the cover to be filled? If your underfloor distributor is to blend in perfectly with its surroundings, filling of the cover is required. There are no restrictions on the type of filling that can be used (cobbles, wood, tar, etc.). 5. Is drainage guaranteed? In order to protect the underfloor distributor from water damage, drainage must be guaranteed through the preparation of appropriate drainage (this is always the client's responsibility). Telephone Fax verkauf@gifas.de 3

4 PIAZZA Overview of PIAZZA 540 / 700 / 1000 PIAZZA 540 PIAZZA 700 PIAZZA 1000 Product features Sturdy, easy to use and safe in operation Can be walked or driven over even during operation Integrates perfectly into its surroundings thanks to customisable filling options Secured against unauthorised opening (vandal-proof) and lockable in the contacted area Easy and quick opening and closing, supported by gas springs Frost-proof operation thanks to cover heating The GIFAS solid rubber distributor guarantees optimum operating safety down to -40 C. No formation of condensation thanks to the GIFAS solid rubber distributor Resistant to environmental influences Stainless steel construction, all metal parts made from V2A with cathodic dip coating Visible reflectors on the opened cover system Distributor fastening on the underside of the cover The connector distributor can be accessed when installed (E-check) Pit cover, lock and distributor can be replaced Technical data PIAZZA 540 PIAZZA 700 PIAZZA 1000 Area of use Internal / external area Internal / external area Internal / external area Classification as per EN kN (40t) / D kN (40t) / D kN (40t) / D400 Cover Covers can be individually filled / paved 580x580x70mm Covers can be individually filled / paved 700x700x70mm Covers can be individually filled / paved 1000x1000x70mm Weight Approx. 350kg Approx. 450kg Approx. 780kg Installation depth Approx. 1200mm Approx. 1300mm Approx. 1300mm GIFAS solid rubber distributors 3800 series 7800 series 7800/7900 series Can be equipped in accordance with the client's wishes (power, water, waste water, compressed air and EDP connections) Fuses 1 CEE built-in socket 5x16A/400V 2 protective contact sockets 1 RCCB 40/0.03A 1 LP 16A / 3-pin 2 LP 16A / 1-pin 1 CEE built-in socket 5x63A /400V 1 CEE built-in socket 5x32A/400V 1 CEE built-in socket 5x16A/400V 3 protective contact sockets 1 LP 63A / 3-pin 1 LP 32A / 3-pin 1 LP 16A / 3-pin 3 LP 16A / 1-pin 1 LP 63A / 3-pin pre-fusing 1 RCCB 63/0.03A / 4-pin for 63A socket 1 RCCB 63/0.03A/ 4-pin for the remaining sockets 1 CEE built-in socket 5x63A/400V 1 CEE built-in socket 5x32A/400V 3 CEE built-in socket 5x16A/400V 6 protective contact sockets 1 LP 63A / 3-pin 1 LP 32A / 3-pin 3 LP 16A / 3-pin 6 LP 16A / 1-pin 1RCCB 63/0.03A for 63A built-in socket 1RCCB 63/0.03A for 16A built-in sockets 1 RCCB 63/0.03A for 32A builtin socket and protective contact sockets 4 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

5 PIAZZA PIAZZA 540 Solid stainless steel construction (V2A) 540 x 540 mm, load capacity up to 400 kn, gas springs for fully automatic opening, shaft cover can be custom-filled, distributor as per the client's request. Technical additions Cover filling: Cable exit flap: Locking: Heating: The pit with a depth of 70 mm can be custom-filled to blend in with its surroundings. (180x130 mm) integrated into the shaft cover frame. a self-cleaning lock with snap fastener closes the shaft cover. Cable exit flap secured with a double bit lock (locking tool included in scope of delivery). the shaft cover contains a selfregulating heating strip which helps to ensure easy opening in the event of frost. It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Supplied package Stainless steel construction with fillable shaft cover solid rubber electrical distributor junction box Fully assembled and wired. Mounted on concrete ring (H = 470 mm, NW = 600 mm). Telephone Fax verkauf@gifas.de 5

6 PIAZZA PIAZZA 700 Solid stainless steel construction (V2A) 700 x 700 mm, load capacity up to 400 kn, gas springs for fully automatic opening, shaft cover can be custom-filled, distributor as per the client's request. Technical additions Cover filling: Cable exit flap: Locking: The pit with a depth of 70 mm can be custom-filled to blend in with its surround ings. (180x130 mm) integrated into the shaft cover frame. A sturdy closing mechanism (with snap lock) closes the shaft cover and it can also be secured with a shackle lock. Cable exit flap secured with a double bit lock (locking tool included in scope of delivery). A self-regulating heating strip is integrated Heating: into the shaft cover in order to ensure easy opening in the event of frost. It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Supplied package Stainless steel construction with fillable shaft cover solid rubber electrical distributor junction box Fully assembled and wired. Mounted on concrete ring (H = 470 mm, NW = 800 mm). 6 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

7 PIAZZA PIAZZA 1000 Solid stainless steel construction (V2A) 1000 x 1000 mm, load capacity up to 400 kn, gas springs for fully automatic opening, shaft cover can be custom-filled, distributor as per the client's request. Technical additions Cover filling: Cable exit flap: Locking: The pit with a depth of 70 mm can be custom-filled to blend in with its surround ings. (180x130 mm) integrated into the shaft cover frame. A sturdy closing mechanism (with snap lock) closes the shaft cover and it can also be secured with a shackle lock. Cable exit flap secured with a double bit lock (locking tool included in scope of delivery). A self-regulating heating strip is integrated Heating: into the shaft cover in order to ensure easy opening in the event of frost. It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Supplied package Stainless steel construction with fillable shaft cover solid rubber electrical distributor junction box Fully assembled and wired. Mounted on concrete ring (H = 470 mm, NW = 1000 mm). Telephone Fax verkauf@gifas.de 7

8 Practical examples PIAZZA Lübeck town hall market, PIAZZA with payment system Lübeck town hall market, PIAZZA with payment system Lübeck town hall market, PIAZZA with payment system Detmold marketplace, PIAZZA 1000 Detmold marketplace, PIAZZA 1000 Detmold marketplace, PIAZZA GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

9 Practical examples PIAZZA Hangar, PIAZZA 700 Hangar, PIAZZA 700 Thyssen, PIAZZA 700 Thyssen, PIAZZA 700 Wiesbaden Assembly Rooms, PIAZZA Wiesbaden Assembly Rooms, PIAZZA Telephone Fax

10 Practical examples PIAZZA Airport PIAZZA 2000 Airport PIAZZA 2000 Munich Residence, PIAZZA 700 Munich Residence, PIAZZA 700 Dresden "Zwinger", PIAZZA 700 Dresden "Zwinger", PIAZZA GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

11 Installation instructions PIAZZA installation and assembly procedure Excavating the installation pit Customer-side concrete ring Insertion of the unit Insertion of the entire unit into the prepared installation pit Levelling Decanting and concreting-in Adaptation to the surroundings with filler material Fully installed PIAZZA With underfloor systems involving fresh water, the terminal distributor must be hung on the side opposite the water tap! Telephone Fax

12 CAMPETTO Overview of CAMPETTO V / VI / VII / VIII Product features Sturdy, easy to use and safe in operation Can be walked or driven over even during operation Integrates perfectly into its surroundings thanks to customisable filling options Secured against unauthorised opening (vandal-proof) and lockable in the contacted area Easy and quick opening and closing, supported by gas springs Frost-proof operation thanks to cover heating option The GIFAS solid rubber distributor guarantees optimum operating Safety down to -40 C. No formation of condensation thanks to the GIFAS solid rubber distributor Resistant to environmental influences Stainless steel construction, all metal parts made from V2A with cathodic dip coating Visible reflectors on the opened cover system Cover pit can be removed by loosening the screws for maintenance purposes Distributor fastening on the underside of the cover The connector distributor can be accessed when installed (E-check) Pit cover, lock and distributor can be replaced Technical data CAMPETTO V CAMPETTO VI CAMPETTO VII CAMPETTO VIII Area of use Internal / external area Internal / external area Internal / external area Internal / external area Maximum load Classification as per EN 124 Cover Up to 30kN (3t), special designs 50kN 125kN (12.5t) Up to 30kN (3t) Special designs 50kN 125kN (12.5t) 15kN (1.5t) / A15 125kN (12.5t) / B125 15kN (1.5t) / A15 125kN (12.5t) / B125 Stainless steel non-slip steel floor plate, can be supplied in two sizes 628x435mm / 778x535mm Covers can be individually filled / paved can be supplied in two sizes 628x435mm / 778x535mm Stainless steel non-slip steel floor plate 880x992mm Covers can be individually filled / paved 880x992mm Weight Approx. 60kg Approx. 70kg Approx. 250kg Approx. 250kg Installation depth Dependent on design Dependent on design 1000mm 1000mm 500 or 670mm 500 or 670mm GIFAS solid rubber distributors Can be equipped in accordance with the client's wishes (power, water, waste water, compressed air and EDP connections) Fuses Individual series 7200 to CEE built-in socket 5x32A/400V 1 CEE built-in socket 5x16A/400V 3 protective contact sockets 1 LP 32A / 3-pin 1 LP 16A / 3-pin 3 LP 16A / 1-pin 1 LP 63A / 3-pin for prefusing 1 RCCB 63/0.03 A / 4-pin for all sockets Individual series 7200 to CEE built-in socket 5x32A/400V 1 CEE built-in socket 5x16A/400V 3 protective contact sockets 1 LP 32A / 3-pin 1 LP 16A / 3-pin 3 LP 16A / 1-pin 1 LP 63A / 3-pin for prefusing 1 RCCB 63/0.03A / 4-pin for all sockets Individual series 7200 to CEE built-in socket 5x63A/400V 1 CEE built-in socket 5x32A/400V 3 CEE built-in socket 5x16A/400V 6 protective contact sockets 1 LP 63A / 3-pin 1 LP 32A / 3-pin 3 LP 16A / 3-pin 6 LP 16A / 1-pin 1 RCCB 63/0.03A for 63A built-in socket 1 RCCB 63/0.03A for 16A built-in socket 1 RCCB 63/0.03A for 32A built-in socket protective contact sockets Individual series 7200 to CEE built-in socket 5x63A/400V 1 CEE built-in socket 5x32A/400V 3 CEE built-in socket 5x16A/400V 6 protective contact sockets 1 LP 63A / 3-pin 1 LP 32A / 3-pin 3 LP 16A / 3-pin 6 LP 16A / 1-pin 1 RCCB 63/0.03A for 63A built-in socket 1 RCCB 63/0.03A for 16A built-in socket 1 RCCB 63/0.03A for 32A built-in socket protective contact sockets 12 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

13 CAMPETTO CAMPETTO V Solid stainless steel construction (V2A) in two sizes, load capacity up to 30 kn (special design up to 50 kn), gas springs for fully automatic opening, shaft cover made from non-slip steel floor plate, distributor as per the client's request. Technical additions Cover: Cable exit flap: Locking: Heating (optional): V2A non-slip steel floor plate (135x90 mm) in the centre on the head side of the cover. a self-cleaning lock with snap fastener closes the shaft cover (locking tool includ ed in the scope of delivery). the shaft contains a self-regulating heat ing strip which ensures easy opening in the event of frost. Sand Gravel Pavement Concrete collar for distributors It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Supplied package Stainless steel construction with cover made from V2A non-slip steel floor plate solid rubber electrical distributor junction box Fully assembled and wired. Sand Gravel Pavement Concrete collar for distributors Telephone Fax verkauf@gifas.de 13

14 CAMPETTO CAMPETTO VI Solid stainless steel construction (V2A) in two sizes, load capacity up to 125 kn, gas springs for fully automatic opening, shaft cover can be custom-filled, distributor as per the client's request. Pavement Technical additions Sand Cover filling: Cable exit flap: Locking: Heating (optional): The pit with a depth of 70 mm can be custom-filled to blend in with its surround ings. (135x90 mm) in the centre on the head side of the cover. a self-cleaning lock with snap fastener closes the shaft cover (locking tool includ ed in the scope of delivery). the shaft contains a self-regulating heat ing strip which ensures easy opening in the event of frost. Gravel Concrete collar for distributors It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Supplied package Stainless steel construction with fillable shaft cover solid rubber electrical distributor junction box Fully assembled and wired. Sand Gravel Pavement Concrete collar for distributors GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

15 CAMPETTO CAMPETTO VII 992 Solid stainless steel construction (V2A), load capacity up to 15 kn (special design up to 50 kn), gas springs for fully automatic opening, shaft cover made from non-slip steel floor plate, distributor as per the client's request. Technical additions Cover: Cable exit flap: Locking: Heating (optional): V2A non-slip steel floor plate (135x90 mm) in the centre on the head side of the cover a self-cleaning lock with snap fastener closes the shaft cover (locking tool includ ed in the scope of delivery). the shaft contains a self-regulating heat ing strip which ensures easy opening in the event of frost. Sand Sand Gravel Kies Pavement Bepflasterung Concrete collar Betonmanschette It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. 940 for distributors Supplied package Stainless steel construction with cover made from V2A non-slip steel floor plate solid rubber electrical distributor junction box Fully assembled and wired. Telephone Fax verkauf@gifas.de 15

16 CAMPETTO CAMPETTO VIII 992 Solid stainless steel construction (V2A), load capacity up to 125 kn, gas springs for fully automatic opening, shaft cover can be custom-filled, distributor as per the client's request. Technical additions Cover filling: Cable exit flap: Locking: Heating (optional): The pit with a depth of 70 mm can be custom-filled to blend in with its surround ings. (280x90 mm) in the centre on the head side of the cover. a self-cleaning lock with snap fastener closes the shaft cover (locking tool includ ed in the scope of delivery). the shaft contains a self-regulating heat ing strip which ensures easy opening in the event of frost. Sand Gravel Kies Pavement Bepflasterung Concrete Betonmanschette collar It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. 940 for distributors Supplied package Stainless steel construction with fillable shaft cover solid rubber electrical distributor junction box Fully assembled and wired. 16 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

17 Practical examples CAMPETTO Bad Saarow station, CAMPETTO VI Bad Saarow station, CAMPETTO VI BUGA Koblenz, CAMPETTO with diving bell BUGA Koblenz, CAMPETTO with diving bell London Olympic Games, CAMPETTO Melitta Minden, CAMPETTO VI Telephone Fax

18 Practical examples CAMPETTO Meckenbeuren church square, CAMPETTO VI Meckenbeuren church square, CAMPETTO VI Daimler presentation hall, CAMPETTO VI Daimler presentation hall, CAMPETTO VI Hotel Grand Spa Resort Sylt, CAMPETTO VI Hotel Grand Spa Resort Sylt, CAMPETTO VI 18 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

19 Practical examples CAMPETTO Max Planck Institute, CAMPETTO VIII Hamburg CruiseCenter, CAMPETTO VIII Town of Illertissen, CAMPETTO VI Pforzheim marketplace, CAMPETTO VI Hampton Court Palace, CAMPETTO VI BUGA Schwerin, CAMPETTO V Telephone Fax verkauf@gifas.de 19

20 Installation instructions CAMPETTO installation and assembly procedure Excavating the installation pit Topping up the installation pit Insertion of the unit Filling Decanting and concreting-in Adaptation to the surroundings with filler material Fully installed CAMPETTO 20 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

21 PICCOLINO PICCOLINO 120 / 200 PICCOLINO 120 PICCOLINO 200 Product features Solid stainless steel construction, rust-free Completely maintenance-free (E-check) Cover made from non-slip steel floor plate Easy operation Can be walked or driven over during operation Ground-flush installation Excellent operating safety thanks to reclosing after commissioning Locking is performed using a countersunk, cover-flush dual bit lock (1 key included in the scope of delivery) Cable exit opening in the cover lid for cables up to d = 15 mm (PICCOLINO 120), d = 25 mm (PICCOLINO 200) It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Technical data PICCOLINO 120 PICCOLINO 200 Area of use Underfloor distributors for restricted spaces Underfloor distributors for restricted spaces Classification as per EN 124 2kN (200kg) 250kN (25 t) / C250 Cover Stainless steel non-slip steel floor plate 120x120mm Weight Approx. 4.2kg Approx. 7.5kg Installation depth Approx. 400mm Approx. 400mm Equipment options 2m GIFAS-PROFLEXX-07 cable 3x2.5 m 2 1 protective contact coupling 16A/230V (IP 68) or 1 CEE coupling 16A/400V (IP67) Stainless steel non-slip steel floor plate 200x200mm 2m GIFAS-PROFLEXX-07 cable 3x2.5 m 2 1 protective contact coupling 16A/230V (IP 68) or 1 CEE coupling 5x16A/400V (IP 67) or 1 CEE coupling 5x32A/400V (IP 67) Twist protection Twist protection Potential Earth cross slot screw Potential Earth cross slot screw Schuko-socket WD 230V 16A holder socket 2m GIFAS PROFLEXX 3x2,5 (connection and shrinking need to be executed at contruction side) Potential Earth M8 bolt 2m GIFAS PROFLEXX 3x2,5 (connection and shrinking need to be executed at contruction side) cable exit square sash fastener cable exit square sash fastener PICCOLINO 120 PICCOLINO 200 Telephone Fax verkauf@gifas.de 21

22 RETRANT RETRANT Product features Solid stainless steel construction, rust-free Completely maintenance-free (E-check) Cover made from non-slip steel floor plate Easy operation Can be walked or driven over during operation Ground-flush installation Excellent safety thanks to the GIFAS double pressure method; the cover is held securely closed even without a lock Locking is performed using a countersunk, cover-flush dual bit lock (1 key included in the scope of delivery) Cable exit for cables is located in the shaft cover It is the client's responsibility to ensure the standards-appropriate substructure, correct installation of the shaft and corresponding drainage. The shaft cover is not sealed against surface water. Technical data RETRANT Area of use Classification as per EN 124 Underfloor distributors for restricted spaces 15kN (1.5t) / A15 Cover Stainless steel non-slip steel floor plate 340x240mm Weight Approx. 25kg Installation depth Approx. 420mm GIFAS solid rubber distributors Series 2516, protection category IP 65 Equipment options Individual as per the client's wishes 1 CEE built-in socket 5x32A/400V in straight design 1 protective contact socket 230V (IP 68) Cable input Stainless steel cover Cable outlet 50 x 50 mm Solid rubber casing type 2516 Lower part steel casing, coated against corrosion 22 GIFAS ELECTRIC GmbH Borsigstrasse Neuss GERMANY

23 Practical examples PICCOLINO / RETRANT PICCOLINO 200 RETRANT, Wiesbaden Assembly Rooms RETRANT, Wiesbaden Assembly Rooms RETRANT, Wiesbaden Assembly Rooms RETRANT, Lübeck town hall market RETRANT, Lübeck town hall market Telephone Fax verkauf@gifas.de 23

24 CONTACT US TODAY Technical modifications reserved 02/2013 New products and specialist solutions, along with the latest product catalogue, can be found on our website. GIFAS ELECTRIC GmbH Borsigstrasse 9, Neuss PO Box , Neuss GERMANY Phone Fax:

Products for the area

Products for the area YOUR WISHES ARE OUR BENCHMARK Products for the area Catalogue 11 Table of contents Cable reels Introduction 502 series Stahl 502 series CEAG 518 series Stahl 518 series CEAG Pages 4-7 Page 3 Page 4 Page

More information

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan Installation plan Washing machine PW 6055 AV/LP PW 6065 AV/LP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation

More information

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan Installation plan Tumble dryer PT 5137 WP PT 7137 WP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Moisture inside the drum is due to final testing. Mains cable. Water outlet

Moisture inside the drum is due to final testing. Mains cable. Water outlet Safety instructions Moisture inside the drum is due to final testing. Scope of delivery depending on model The washing machine is heavy - take care when lifting. Caution: frozen hoses can crack/burst.

More information

Hydraulic crimping tool. HO-16 Art QZERTIFIKAT DIN EN ISO convincing solutions

Hydraulic crimping tool. HO-16 Art QZERTIFIKAT DIN EN ISO convincing solutions Hydraulic crimping tools INSTRUCTION MANUAL Hydraulic crimping tool HO-16 Art. 216802 DIN EN ISO 9001 QZERTIFIKAT 1. Technical data Area of application: For the creation of an electrical connection by

More information

Cutting Tools. Hydraulic cutting heads Hydraulic drive units Hydraulic systems

Cutting Tools. Hydraulic cutting heads Hydraulic drive units Hydraulic systems Cutting Tools Hydraulic cutting heads Hydraulic drive units Hydraulic systems Cutting tools Hydraulic cutting heads SDG 85 SDG 85, SDG 105 Hydraulic cutting heads max. Ø 85 mm and Ø 105 mm Cut armoured

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport safety devices Water connection depending on model The washing machine

More information

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Adsorption dryer PDAD. (en) Operating instructions g [ ] Adsorption dryer PDAD (en) Operating instructions 8068814 1701g [8068816] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with the operating

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000PC SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing IMPORTANT : PLEASE READ BEFORE INSTALLATION.. Do not connect this remote

More information

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1 Quartz Digital Bath with bath waste filler The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical and

More information

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan Installation plan Washing machine PW 5064 MOPSTAR 60 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Hydraulic crimping tool. HO-6 Art convincing solutions

Hydraulic crimping tool. HO-6 Art convincing solutions Hydraulic crimping tools INSTRUCTION MANUAL Hydraulic crimping tool HO-6 Art. 216802 1. Technical data Area of application: For the creation of an electrical connection by means of compression Scope of

More information

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan Installation plan Tumble dryer PT 5135 C PT 7135 C To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL VANTAGE with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

INSTRUCTION MANUAL FOR MINI SUCTION UNIT

INSTRUCTION MANUAL FOR MINI SUCTION UNIT INSTRUCTION MANUAL FOR MINI SUCTION UNIT MINI SUCTION UNIT WITH DISPOSABLE SALIVER TANK. MINI SUCTION UNIT WITH STANDARD SALIVER TANK MINI SUCTION VERSION DATE 15.02.2011 VERSION NO : 1-2011 1 1. General

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL Vail with DC motor 10/15 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A) EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Product Catalogue WB Engineering Containers. fast inexpensive safe flexible certified

Product Catalogue WB Engineering Containers. fast inexpensive safe flexible certified Product Catalogue WB Engineering Containers fast inexpensive safe flexible certified Table of Content Product Catalogue Key data WBEC - Standard & Premium Key data WBEC - Standard model Key data WBEC Premium

More information

LINDOFLAMM thermal engineering.

LINDOFLAMM thermal engineering. Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering

More information

floatone Product Description

floatone Product Description floatone Product Description as at: January 2016 History float Since the beginning of 2004, we have been operating a float spa in the Munich district of Schwabing. It is open 7 days a week and offers

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL Style that revolves around you. CEILING FAN OWNER S MANUAL Total fan weight *53 lbs. WEXFORD 11/05 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL GRANDER (GN) with DC motor 03/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL

More information

Service package PDAD- -SP (en) Assembly instructions d [ ]

Service package PDAD- -SP (en) Assembly instructions d [ ] Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with

More information

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A) EN Installation manual surface mounting plugs and socket outlets, panel 60003506 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Think connected. Conducting electricity. Routing data. Controlling energy.

Think connected. Conducting electricity. Routing data. Controlling energy. This is OBO Think connected. Conducting electricity. Routing data. Controlling energy. Welcome to OBO Discover what drives our company. How we bundle our high-quality products into innovative systems.

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

O p e r a t i n g I n s t r u c t i o n s

O p e r a t i n g I n s t r u c t i o n s O p e r a t i n g I n s t r u c t i o n s www.masterblasterfoam.co.uk Page 1 of 10 Contents Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Introduction & Features Safety Instructions Warnings,

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000BZGTGLD SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing WARNING To make sure power is off before attempting installation. WARNING

More information

BEVERAGE CONDUIT SYSTEMS

BEVERAGE CONDUIT SYSTEMS BEVERAGE CONDUIT SYSTEMS MATERIALS CONSULTING INSTALLATION March 2012 Easybar Beverage Management Systems A EASYBAR BEVERAGE CONDUIT SYSTEMS COMPLETE BEVERAGE CONDUIT ROUTING SYSTEMS FOR THE BEVERAGE INDUSTRY

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL NO.: ISSUED: REVISED: 73091 DEC. 21, 1999 DEC. 17, 2003 HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service

More information

Performance Specifications LSF LIFT-SMOKE-FREE

Performance Specifications LSF LIFT-SMOKE-FREE Performance Specifications LSF LIFT-SMOKE-FREE Lift shafts and machinery rooms must be ventilated and equipped with a smoke and heat exhaust ventilation (SHEV) system in accordance with the currently valid

More information

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR CONDITIONING BASICS COMPRESSOR REPLACEMENT OVERVIEW AND IMPORTANT INSTRUCTIONS The air conditioning compressor

More information

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario Bentley II 13 in Ceiling Fan Owner s Manual Bentley II Ventilador de Techo de 33 cm Manual del Propietario 326 960 Bentley II by Hampton Bay 13 Bentley II Ceiling Fan by Hampton Bay Thank you for purchasing

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions CHEOPS for Pre-Filter Module Order No. CHEOPS 0015 CHEOPS and Main Filter Module Order No. CHEOPS 0010 Before putting the filter system into operation please carefully

More information

Manual. Above-counter dispenser for hot drinks OTHG /12

Manual. Above-counter dispenser for hot drinks OTHG /12 Manual Above-counter dispenser for hot drinks OTHG 105 1 It is in your own interests to observe all the hazard and safety information. This helps you to prevent accidents and technical malfunctions. Only

More information

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV Fitting and operating instructions EN BWT ECO Ultra Violet Water Disinfection System ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV BWT ECO Range /06-2016 BWT UK Limited Changes of technical details are reserved

More information

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH GTL-2 430-2410-101 EN10 EN Operating manual GSME Tester GTL-2 GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 D-41747 Viersen, GERMANY info@gte.de +49(0)2162 / 3703-0 www.gte.de Operating manual Dokument

More information

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC Series PX Installation & Maintenance Models: PX-3 PX-5 PX-7 /2-HF PX-0-HF PX-5-HF Materials: A - CPVC Introduction Penguin Pumps are designed to handle a large range of chemicals without difficulty. Completely

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions OPERATOR S MANUAL & PARTS LIST MULTIWASH XL PFMW18 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. Tacony, Inc., All rights reserved Save These Instructions

More information

Hakki Pilke Raven spare parts manual

Hakki Pilke Raven spare parts manual 1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section

More information

Dry Bath Heating Systems

Dry Bath Heating Systems Dry Bath Heating Systems Instruction Manual N2400-4001 Dry Bath Heating System, Single Block, Digital N2400-4002 Dry Bath Heating System, Dual Block, Digital www.starlabgroup.com DECLARATION OF CONFORMITY

More information

Electro-hydraulic crimping tools. HD400-6 Art HD300-6 Art convincing solutions

Electro-hydraulic crimping tools. HD400-6 Art HD300-6 Art convincing solutions Hydraulic crimping tools INSTRUCTION MANUAL Electro-hydraulic crimping tools HD400-6 Art. 216661 HD300-6 Art. 216660 convincing solutions 1. Technical data Area of application: For the creation of an electrical

More information

Environmental and oil cabinets The optimum storage area for liquids

Environmental and oil cabinets The optimum storage area for liquids Environmental and oil cabinets The optimum storage area for liquids Lista environmental cabinets are suitable for the safe and standard storage of waterhazardous substances in water hazard class (GK) 1-3.

More information

Service Manual Q MODEL DISPENSER Q160/290/300

Service Manual Q MODEL DISPENSER Q160/290/300 Q MODEL DISPENSER Q160/290/300 Service Manual Thank you for selecting a Manitowoc Dispenser, the dependability leader in ice making equipment and related products. With proper care and maintenance, your

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL CIARA 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION

More information

Installation manual plugs and connectors QUICK-CONNECT (63 A)

Installation manual plugs and connectors QUICK-CONNECT (63 A) EN Installation manual plugs and connectors QUICK-CONNECT (63 A) 60003217 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal

More information

Product Information. Brushes. Drum brace cable

Product Information. Brushes. Drum brace cable Product Information Mega-Polisher Washing & Polishing Equipment Top cover Sliding door Infeed chute Drum drive belt Drum motor gearbox Brush motor gearbox Brush drive belt Synchronous belt Drum Brushes

More information

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting EN Installation manual extra-low-voltage socket outlets for panel- and 60003221 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal

More information

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS and Retrofit of G2E Quick Release Cushion Upholstery 1 OF 32 A 1.0 PURPOSE: To replace both Back and Cushion Upholstery on the G2E seats. 2.0 Tools Required: 2.1 1/2 Socket and Wrench 2.2 5/8 Socket 2.3

More information

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

More information

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens. 103592 Zip Econoboil 3.0 litre White HS503 105592 Zip Econoboil 5.0 litre White HS505

More information

Vertical Ring-section Pump WKTB. Type Series Booklet

Vertical Ring-section Pump WKTB. Type Series Booklet WKTB Type Series Booklet Legal information/copyright Type Series Booklet WKTB All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for

More information

Operating Instructions

Operating Instructions Operating Instructions Varioset Standard After-sales service For after-sales service please contact the Veit representative in your country. GmbH & Co. Justus - von - Liebig - Str. 15 D - 86899 Landsberg

More information

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction tubes and floor nozzles can be stored in any direction in the accessory holders

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction tubes and floor nozzles can be stored in any direction in the accessory holders NT 65/2 Tact² Tc The Kärcher Tact² systems are ever popular as specialist systems and as all-rounders thanks to their high level of mobility and excellent performance, their solid construction and their

More information

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461 User and Installation Instructions Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461 Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance as described

More information

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO ECO FDC/ -B Product information SYSTEM TECHNOLOGY FOR THE DOOR FDC / -B Product characteristics FDC FDC- B Closing force Size acc. to EN (continuously adjustable) 3 6 4 6 Door width acc. to EN Dimensions

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS SUBMERSIBLE PUMPS MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A PART NO: 7236042, 7236044, 7236050 & 7236060 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC07/17 iss 4 INTRODUCTION Thank you for

More information

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled 2015 GLUE PUMPS for Labelling Machines NEW MODEL 2015 ADVANTAGES: hoseproof IP66 programmable NFC-enabled Timmer GmbH Dieselstraße 37 D-48485 Neuenkirchen Tel.: +49 5973 9493-0 Fax: +49 5973 9493-90 www.timmer.de

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5

More information

VC-1, VC-1-SL, VC-2-L, VC-2-SL

VC-1, VC-1-SL, VC-2-L, VC-2-SL Pre-Cooling Unit Series VC VC-1, VC-1-SL, VC-2-L, VC-2-SL Instruction Manual Version 1.00.02 Dear customer, we have made up this operating manual in such a way that all necessary information about the

More information

BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER

BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER EN (fi gure 1) BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER CONTROL PANEL The thermostat box to control the appliance is

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL Hover with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water heater for beverages. Model No. Description Reg.No. Part No. HS503 Zip Econoboil 3.0 litre White EB003 103592 HS505

More information

Automatic Mixer Operating Instructions

Automatic Mixer Operating Instructions English Automatic Mixer Operating Instructions PROTEC Medizintechnik GmbH & Co. KG Lichtenberger Strasse 35, D-71720 Oberstenfeld, Germany Telephone: +49-7062-9255-0 e-mail: service@protec-med.com Machine

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

PackardInfo.com. HOW TO: Rebuild a Trico Mag Nu Matic Vacuum Washer Pump. Introduction

PackardInfo.com. HOW TO: Rebuild a Trico Mag Nu Matic Vacuum Washer Pump. Introduction Introduction So here hopefully ends the saga of my Trico Mag Nu Matic washer pump. I found the pump at the 2009 Packards International swap meet for $35. I thought I had the deal of a lifetime as it looked

More information

Service Manual. Ice Dispensing Bin Models DB-200H. hoshizakiamerica.com

Service Manual. Ice Dispensing Bin Models DB-200H. hoshizakiamerica.com Service Manual Ice Dispensing Bin Models DB-200H hoshizakiamerica.com Number: 73136 Issued: 5-8-2006 Revised: 2-19-2018 IMPORTANT Only qualified service technicians should attempt to service or maintain

More information

E nglish. Steaker Strip cutter Tenderizer

E nglish. Steaker Strip cutter Tenderizer E nglish Steaker Strip cutter Tenderizer Steaking Strip cutting Tenderizing For meat and salad Use our steakers and strip cutters to quickly and efficiently process meat, sausages, cheese and vegetables,

More information

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX Owner s Guide and Installation Manual 3MAVR60XX Series Fan UL Model NO. : 3MAVR60XX Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Hose and cable lengths depending on model Scope of delivery depending on model AquaäStop AquaäSecure or Left-hand connection ~ 100 cm ~ 145 cm ~ 145 cm ~ 95 cm Moisture inside the drum is due to final

More information

Pool Protector OPERATING INSTRUCTIONS MANUAL

Pool Protector OPERATING INSTRUCTIONS MANUAL Pool Protector OPERATING INSTRUCTIONS MANUAL MEETS NF90-307 CE R&TTE This product has been designed to aid in the detection of unwanted intrusions into unsupervised pools. POOL PROTECTOR IS A SAFETY ALARM

More information

Part 2: Installation Instructions cl

Part 2: Installation Instructions cl Contents Page: Part 2: Installation Instructions cl. 381-382 1. Delivery scope............................... 3 2. General and Transportation safety precautions........... 3 3. Stand installation 3.1 Installing

More information

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G Gas unit Voltage 1NAC 230V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door 9 9

More information

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E Electrical unit Voltage 3NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door

More information

Tumble dryer PT 5136 PT en - GB. Installation plan

Tumble dryer PT 5136 PT en - GB. Installation plan Installation plan Tumble dryer PT 5136 PT 7136 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for HUALING HUALING heating elements/thermostats heating elements heating elements for fryers 2 hole

More information

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment NT 75/2 Ap Me Tc High-performance, dual-motor wet/dry vacuum cleaner for professional use. Effective airblast cleaning of the flat pleated filter maintains virtually constant cleaning power. 1 2 3 4 1

More information

SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL

SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL Sentry MK 2 ENVIRONMENTAL NOISE CONTROL SYSTEM FUNDAMENTALS Noise nuisance legislation requires sound levels to be controlled within limits, for licensed premises

More information

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE EDITION EN5113 5 US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) US ARMY PLUMBER MOS 51K SKILL LEVELS 1 AND 2 COURSE PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE NO. EN5113 US Army Engineer

More information

Easy Conveying VACUUM CONVEYING TEC. DUST AND PARTICLE FILTERS CONTROL UNITS PNEUMATIC SUPPLIES BIG-BAG STATIONS

Easy Conveying VACUUM CONVEYING TEC. DUST AND PARTICLE FILTERS CONTROL UNITS PNEUMATIC SUPPLIES BIG-BAG STATIONS Easy Conveying VACUUM CONVEYING TEC. DUST AND PARTICLE FILTERS CONTROL UNITS PNEUMATIC SUPPLIES BIG-BAG STATIONS Greater productivity in industrial materials conveying through modern vacuum technology.

More information

Underlaminate Foil Heater

Underlaminate Foil Heater Installation Manual: Underlaminate Foil Heater TECHNICAL HELPLINE 0845 345 2288 n online at warmup.co.uk IMPORTANT Read this manual before attempting to install your foil heater. Incorrect installation

More information

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450 1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside

More information

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Crimping tool HHs-6. Art convincing solutions. Video

Crimping tool HHs-6. Art convincing solutions. Video Hydraulic crimping tools INSTRUCTION MANUAL Crimping tool HHs-6 Art. 215765 Video 215765 1. Technical data Art. 215765 Area of application: For the creation of an electrical connection by means of compression

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL

More information

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic.

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic. Installation Instructions Cassette toilet for recreational vehicles Saneo B Saneo C Saneo BLP Saneo CLP Saneo BS Saneo CS Saneo BW Saneo CW N 0 R - 04737 EN MBA 03/05 English Saneo B Saneo C For your safety

More information

COMPONENT SOLUTIONS for the lighting industry

COMPONENT SOLUTIONS for the lighting industry COMPONENT SOLUTIONS for the lighting industry optimascomponents.com QUALITY, COMPONENTS & SERVICE OPTIMAS COMPONENTS CHINA, DESIGN & SOURCING Component Solutions for the Lighting Industry Optimas Components

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL QUATRO 10/09 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007 Assembly- and Usermanual Rainmaker Code No. 99-97-1729 GB Edition: 09/2007 Table of contents Page I 1 Overview and system specifications.................................. 1 1.1 Purpose of Evaporative

More information