LOW PRESSURE SYSTEM INSTALLATION GUIDE

Size: px
Start display at page:

Download "LOW PRESSURE SYSTEM INSTALLATION GUIDE"

Transcription

1 WWW. LOW PRESSURE SYSTEM.CO.ZA INSTALLATION GUIDE Important: The VENT pipe must be OPEN, else the tank will burst when water boils. Fill tubes with water before inserting Cold water in Hot tubes will shatter tubes. Lubricate glass tubes with soapy water before inserting. DO NOT use grease, vaseline, oil, etc.

2 The vent pipe on the top of the geyser tank must always be open to the atmosphere. These systems boil easily, and the steam must escape. Do not use any valve or restriction on the vent pipe. This will void any guarantee. When connecting inlets and outlets, remember that the stainless steel tank is only 0,41mm thick. Do not over tighten. Tips when installing low pressure systems: Remember that the system works best when facing north. The optimal angle for the glass tubes is latitude +10o. For the Pretoria area it will be ± 35o.The stand is designed for 38o, so the stand can be used without any modification. When installing on a 26o pitch roof the short leg with the right angle end is not installed. The angle of the roof plus the remaining angle of the stand will give the required ± 35o. How to assemble the stand: The tank holders, thus the parts on which the tank rests, are in the box marked water tank. All the other parts are in the long, thin box marked bracket If the stand is mounted on a 26 degree roof, the rear upright foot is not installed. The white plastic washer is fitted on the side of the nut. There are three horizontal bars (J profiles): One has only the two holes at the ends: Always fitted at the rear of the stand, in the lowest hole (for horizontal or 26 degree roofs) The one with the two holes closest to the middle is always to the rear, under the tank, together with the long cross struts. In the 100 litre systems, when fitted on a 26 degree roof, the cross struts actually cross. The horizontal bar with the two holes the farthest from the middle, goes in the front of the stand, under the glass tubes, together with the two short cross struts. Glass tubes: To insert the glass tubes, take a mug of water and add some dishwasher liquid. Wet the open side of the glass tube by dipping into the soap water. Insert the tube in to the hole, using a screw in motion. Take care not to make the angle between the stand and the tube too big, as it may cause the tube to break. Pull the tube back to fit into the hole in the stand.

3 Anode: Like any geyser, these solar geysers must also be fitted with an anode. Made from magnesium, scale and rust will first deposit on the anode. Yearly inspection of the anode, and replacement when necessary, will make the geyser last much longer. The anode has a plastic connector which fits into a glass tube, and gets inserted into the tank together with the glass tube. To remember on which tube the anode is fitted, we try to put it as close to the inlet/outlet. When connecting vent: The vent pipe is connected to the inner tank with a silicon washer. Use a spanner or vise grip to hold the pipe in place. Be careful not to force the vent pipe into or out of the tank, or not to turn the pipe axially. If this happens, it will feel as if the pipe breaks loose, and you will be able to turn the pipe axially. It will not leak, because only the bond between the metal pipe and the poly urethane insulating foam breaks. With no electric element installed: Manual filling: Connect a pipe to the bottom male thread (marked Outlet ). This pipe can then act as both an inlet and outlet pipe. A Tee coupling is connected in the pipe. One end of the Tee gets connected to a valve and the cold water supply. The other end of the Tee gets connected to the hot water outlets. In the morning, while the hot water taps are closed, open the inlet valve and let the water fill the tank until it runs out through the vent. Close the inlet valve. The tank is full. Let the water heat during the day. In the evening or early morning, when the outlets are opened, the tank runs empty without cold water entering, as happens with the automatic filling methods. This way, there is more available hot water. There will be no damage to the geyser if it runs empty, because the tubes stay full of water. At installation, or when the vacuum tubes are allowed to boil dry, (usually after the tank was empty for a few days), do not pour cold water into the geyser in daytime, because adding cold water into hot, dry tubes will shatter the glass tubes. Notes: This method can be automated using a day/night switch together with a Latco valve or auxiliary tank. Using a GEYSER WISE controller, this can be done electronically, but the sensors are not stable under the high South African water temperatures.

4 Bottom of supply tank just above geyser tank: The top of the vent pipe must be at the same height as the top of the supply tank. The water level in the vent pipe on the geyser tank will be the same as in the supply tank. No Latco valve or auxiliary tank is used. Pressure will be balanced at the shower. The 22mm inlet is at the top and the 22mm outlet is at the bottom, as marked on the tank. The cold water runs out first, but the outflow is better, because the tank can run empty. There is still hot water available when the supply tank is empty. There will be no damage to the geyser if it runs empty, because the tubes stay full of water. At installation, or when the vacuum tubes are allowed to boil dry, (usually after the tank was empty for a few days), do not pour cold water into the geyser in daytime, because adding cold water into hot, dry glass tubes will shatter the tubes. 1. If the bottom of the supply tank is 3 to 5 metres above geyser tank: (when the vent pipe is longer than 1.5m, and thus too long to be stable) or 2. the pressure difference will be so small that it will not significantly effect the mixing at the mixing valve, or 3. if there are no mixing valves, and a difference between cold and hot water is acceptable, there are two options: 1. 3 litre Auxiliary (feeder) tank: It is a 3 litre tank with a ball valve, like a toilet cistern, used to bring down the pressure and keep the geyser tank full. The auxiliary tank cannot be used to balance pressures for the mixer valve (shower) If you have no mixing valve in the house, and differing pressures at the hot and cold outlets is not a problem, it can be used to install where the inlet pressure is high. If the hot/cold pressure difference (difference in head) is small, there should not be serious problems at the shower. Using a 22mm to 15mm reducer, the auxiliary tank can be fitted on the inlet, with a short vent pipe on the 15mm vent. (if you do not have a reducer, the two pipes can be switched.)

5 The 22mm inlet is at the top and the 22mm outlet is at the bottom, as marked on the tank. The cold water runs out first, but the outflow is better, because the tank can run empty. There is still hot water available when the supply tank is empty. There will be no damage to the geyser if it runs empty, because the tubes stay full of water. At installation, or when the vacuum tubes are allowed to boil dry, (usually after the tank was empty for a few days), do not pour cold water into the geyser in daytime, because adding cold water into hot, dry glass tubes will shatter the tubes kPa (Black an white) adjustable Latco valve : It can be bought from The Sun Pays or from the local hardware store. A Latco Valve can be used to equalise the pressure for the mixer valve (shower) If the valve is used to equalise the hot and cold pressure, the cold water is taken off on the low pressure side of the Latco Valve. The 22mm inlet is at the top and the 22mm outlet is at the bottom, as marked on the tank. The cold water runs out first, but the outflow is better, because the tank can run empty. There is still hot water available when the supply tank is empty. When the Latco valve is installed, adjust the white ring on the Latco valve so that the water runs out at the top of the vent pipe, and then back, so the water level is in the vent pipe. There will be no damage to the geyser if it runs empty, because the tubes stay full of water. At installation, or when the vacuum tubes are allowed to boil dry, (usually after the tank was empty for a few days), do not pour cold water into the geyser in daytime, because adding cold water into hot, dry glass tubes will shatter the tubes. With electric element installed: 1) Bottom of supply tank just above geyser tank: The top of the vent pipe must be at the same height as the top of the supply tank. The water level in the vent pipe on the geyser tank will be the same as in the supply tank. No Latco valve or auxiliary tank is used. Pressure will be balanced at the mixer valve (shower). The inlet is at the 22mm male thread (marked Outlet ) at the bottom of the tank. The outlet is at the 22mm male thread (marked Inlet ) at the top of the tank. This way, the tank cannot run dry, and the heating element will not be damaged.

6 2) 100kPa (Black an white) adjustable Latco valve : Latco valves can be bought from The Sun Pays or from the local hardware store. A Latco Valve can be used to equalise the pressure at the mixer valve (shower) If the valve is used to equalise the hot and cold pressure, the cold water is taken off on the low pressure side from the Latco Valve. The inlet is at the 22mm male thread (marked Inlet ) at the top of the tank. The outlet of the geyser tank is at the 22mm male thread (marked Outlet ) at the bottom of the tank. An anti siphon loop, about 12cm higher than the outlet, must be connected to the breather pipe to protect the element. When the Latco valve is installed, adjust the white ring on the Latco valve so that the water runs out at the top of the vent pipe, and then back (½ or ¼ turn), so the water level is in the vent pipe. This way, the heating element cannot run dry, and will not be damaged.

7 3) 6 Litre feeder tank (black and white) with high flow ball valve: The high flow ball valve valve can be used to equalise the pressure at the mixer valve (shower). If the valve is used to equalise the hot and cold water pressure, the tank is installed right above the cold water take off (to the mixer valves). The inlet is at the 22mm male thread (marked Inlet ) at the top of the tank. The outlet of the geyser tank is at the 22mm male thread (marked Outlet ) at the bottom of the tank. An anti siphon loop, about 12cm higher than the outlet, must be connected to the breather pipe to protect the element. The breather pipe on the anti siphon loop must be as high as the top of the feeder tank. This way, the heating element cannot run dry, and will not be damaged.

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC). Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC). Please follow the installation instructions carefully, AND check the final installation according to the

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Can use Standard Copper, CPVC or PEX Pipes Pump Existing Water Heater Bottom Feed Connector 1 Introduction This document describes how to install

More information

SunRay 1000 Solar Water Pasteurizer Installation Instructions

SunRay 1000 Solar Water Pasteurizer Installation Instructions SunRay 1000 Solar Water Pasteurizer Installation Instructions Safe Water Systems, Inc. 1600 Kapiolani Blvd., Suite 721 Honolulu, Hawaii 96814 Phone: 808-949-3123 Fax: 808-949-3103 E-mail: info@safewatersystems.com

More information

Frequently Asked Questions Solar Collector G24

Frequently Asked Questions Solar Collector G24 Frequently Asked Questions Solar Collector G24 The installation and use of the collector is very simple. Here we have tried to answer the questions we get very comprehensively, for those who would like

More information

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2 BLADE BATH MIXER DECK MOUNTED CHR WITH KIT 20007014600 INSTRUCTIONS P5-65511339-1-BS-E A/2 20007014600 INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future

More information

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1 Aquatique Shower heads Fixed and adjustable height heads Aquatique shower kits installation guide page 1 Components Aquatique adjustable height shower kit concealed Chrome 560.01 / Gold 560.04 Aquatique

More information

Heating Systems OWNER S MANUAL. Hea ng Center

Heating Systems OWNER S MANUAL. Hea ng Center Heating Systems OWNER S MANUAL Hea ng Center CE70069 Clean Energy Heating Systems, LLC 540 Maple Street, Honey Brook, PA 19344 www.cleanenergyheatingsystems.com (888) 519-2347 10/21/13 Part # 70005 TABLE

More information

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL IMPORTANT: Please read this manual carefully before using the product. Retain owner s manual for future reference. For Customer Service, please contact:

More information

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Mixermate Instructions Shower 2018 www.mixermate.com.au [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Page 1/5 Shower Installation Instructions 2018 What you will need. Tape measure.

More information

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted Wave BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted WAVE MONO BATH SHOWER MIXER 20004011860 INSTRUCTIONS B For any further information please contact Bathstore on: 0845 873 8843 Or visit our web-site

More information

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington ZEROwaste HX PERC SYSTEM USER MANUAL AIR QUALITY LABORATORIES Seattle, Washington 1 IMPORTANT FILTER MAINTENANCE Refer to the description and diagram on the next pages to identify filter housings A, B

More information

Installation guide PRO7-VAQ E. Before installing read this guide first

Installation guide PRO7-VAQ E. Before installing read this guide first Installation guide PRO7-VAQ E Before installing read this guide first Introduction The operation of the Quooker PRO7-VAQ E The Quooker system consists of a small tank under the sink which is connected

More information

For our present, For their future. Version 11.04

For our present, For their future. Version 11.04 For our present, For their future. SFH-S1 Series Solar Water Heater Assembly Manual Content http://www.sunflower-solar.com/ 1. FEATURES...3 2. SOLAR WATER HEATER SIZE AND WEIGHT...4 3. HOW TO TRANSPORT

More information

METRO BASIN MONO MIXER CHR

METRO BASIN MONO MIXER CHR METRO BASIN MONO MIXER CHR 20004010020 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3.

More information

Solar water heating system

Solar water heating system Solar water heating system Perhaps the most popular application of solar systems is for domestic water heating. The popularity of these systems is based on the fact that relatively simple systems are involved

More information

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump

More information

Oblo Basin and Bidet Monobloc Installation and User Guide

Oblo Basin and Bidet Monobloc Installation and User Guide Oblo Basin and Bidet Monobloc Installation and User Guide MODEL NUMBERS 10085W-CP, 10088W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the

More information

Operators manual Slim/B Water heater

Operators manual Slim/B Water heater Operators manual Slim/B Water heater Isotemp Slim water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Installation guide COMBI E. Before installing read this guide first

Installation guide COMBI E. Before installing read this guide first Installation guide COMBI E Before installing read this guide first Introduction The operation of the Quooker COMBI E The Quooker COMBI E supplies boiling water and hot water. The tank is vacuuminsulated

More information

Handshower, Hose & Handshower Accessories

Handshower, Hose & Handshower Accessories P24443, P24445, P24446, P24452, P24453, P24456 1 of 6 INSTALLATION INSTRUCTIONS Thank You For Choosing KALLISTA We appreciate your commitment to KALLISTA quality products. Please take a moment to review

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding

More information

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector Atmos EasySolar Installation Instructions for Atmos EasySolar Sloping roof and flat roof installation with evacuated tube collector Atmos Heating Systems TBS Building Supplies Ltd Hackwood Road Daventry

More information

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1 Quartz Digital Concealed with adjustable height and fixed head The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European

More information

Installation Manual Thermosiphon - Indirect

Installation Manual Thermosiphon - Indirect Thermosiphon - Indirect Thermosiphon Double Jacketed Indirect system INDEX: Page: 2 3 3 3 3 4 4 4 4 5 6 9 10 10 11 12 13 13 14 14 15 16 17 18 19 20 Components. Thermal Properties. Technical Specifications.

More information

METRO BATH FILLER MOUNTED CHR

METRO BATH FILLER MOUNTED CHR METRO BATH FILLER MOUNTED CHR 20004010050 For any further information please contact Bathstore on: 0845 873 8843 INSTRUCTIONS Or visit our web-site at www.bathstore.com P5-6P8P7-B-BS-E A/4 The manufacturer

More information

HEATING AND VENTILATION

HEATING AND VENTILATION SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,

More information

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS DIAL EXPOSED THERMO SHOWER VALVE For any further information please contact Crosswater on: Or visit our web-site at www.crosswater.co.uk The manufacturer reserves the right to make technical modifications

More information

GT842 INSTALLATION MANUAL. ATTENTION INSTALLERS: These instruc ons must be le with the customer

GT842 INSTALLATION MANUAL.  ATTENTION INSTALLERS: These instruc ons must be le with the customer INSTALLATION MANUAL GT842 www.insigniarange.co.uk 30 Day Technical Support: 01908 226545 (NOTE: This service is only available to customers from the day of delivery, please have your supplier s details

More information

Installation guide Nordic mixer taps. Before installing read this guide first

Installation guide Nordic mixer taps. Before installing read this guide first Installation guide Nordic mixer taps Before installing read this guide first Introduction Installation, maintenance and warranty The Nordic Twintaps are our latest innovation for your kitchen a boiling-water

More information

HOT TANK INSTALLATION INSTRUCTIONS

HOT TANK INSTALLATION INSTRUCTIONS HOT TANK INSTALLATION INSTRUCTIONS Model #: 5000 4500 (PRV) 5000 INSTALLATION GUIDE BEFORE YOU BEGIN YOUR INSTALLATION: 1 2 3 4 Turn off water supply. Observe all local plumbing codes. Inspect waste and

More information

Installation guide PRO3. Before installing read this guide first

Installation guide PRO3. Before installing read this guide first Installation guide PRO3 Before installing read this guide first Introduction The operation of the Quooker PRO3 The Quooker system consists of a vacuum-insulated tank, which is connected to the cold water

More information

Installation guide VAQ E. Before installing read this guide first

Installation guide VAQ E. Before installing read this guide first Installation guide VAQ E Before installing read this guide first Introduction The operation of the Quooker VAQ E The Quooker system consists of a small tank under the sink which is connected to the Nordic

More information

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO TABLE OF CONTENTS ROOM SPECIFICATIONS ELECTRICAL SPECIFICATIONS PLUMBING SPECIFICATIONS TECHNICAL SPECIFICATIONS INTRODUCTION ASSEMBLY

More information

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Panel Radiators. Installation and operating instructions.   ThermaRad Classic. ThermaRad Hurlcon Panel Radiators Installation and operating instructions ThermaRad Classic ThermaDesign ThermaStyle www.hurlconheating.com.au enquiries@hurlconheating.com.au Melbourne: 03 9554 2275 Sydney:

More information

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz greenleaftraders@gmail.com Greenleaf 400 Macerator Toilet Waste Pump Introduction The Greenleaf

More information

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DIRECT DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Heaters - Close Coupled & Split - Direct System direct

More information

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER GREENGLO MAINS PRESSURE INTEGRATED WATER HEATER SINGLE COIL SERIES & DOUBLE COIL SERIES GREENGLO SAVER Customer Congratulations for choosing a GreenGlo

More information

Power Tower OWNER'S MANUAL

Power Tower OWNER'S MANUAL Power Tower OWNER'S MANUAL Model No. PTG Recreation Supply Inc. P.O. BOX BODYCRAFT is a division of Recreation Supply Sunbury, OH 7 MB BEFORE YOU BEGIN Congratulations and thank you for selecting the POWER

More information

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors Atmos EasySolar Installation Instructions for Atmos EasySolar In-roof and flat roof installation with flat plate collectors Atmos Heating Systems West March Daventry Northants, NN11 4SA Tel: 01327 871990

More information

Advanced hygienic Serial and Loop plumbing from Uponor eliminates Dead Legs. Designed for hygiene. Designed for flexibility

Advanced hygienic Serial and Loop plumbing from Uponor eliminates Dead Legs. Designed for hygiene. Designed for flexibility 01 Advanced hygienic Serial and Loop plumbing from Uponor eliminates Dead Legs Designed for hygiene Loop and serial installations are more hygienic than traditional T-piece systems because the risk of

More information

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference.

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference. Basin Mixer Installation & Aftercare Instructions Please retain for future reference. This guide covers the installation of all basin mixer varients. Please select the installation diagram suited to the

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size

More information

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1 Introduction The Bottom Feed solar water heater connector is meant to connect solar water heater panels directly to your existing standard water heater. It's main advantages are ease of installation, efficiency,

More information

Electric Honey Extractor

Electric Honey Extractor Electric Honey Extractor Instruction Manual SKU: BEE-V004E Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product. https://vivo-us.com/products/bee-v004e

More information

Revision 3. April Owner s Manual. Serial Number Here. Date of Purchase

Revision 3. April Owner s Manual. Serial Number Here. Date of Purchase Revision 3 April 2012 Owner s Manual Serial Number Here Date of Purchase www.batcafitness.com 1207 New Hope Road, Raleigh, NC - 919.255.1233 Omega 4 Owner s Manual - www.batcafitness.com Instructions Congratulations

More information

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1 Quartz Thermo Concealed shower valve with adjustable head Quartz Thermo installation guide page 1 Shower systems Components Quartz Thermo built-in shower valve with adjustable head QZ3111 Quartz Thermo

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Please read carefully and retain for future reference. CONTENTS 1. Important Information 2. Included Parts 3. Filter Head Assembly Instructions 4. Installation Instructions 4.1. Auxiliary Tap Connection

More information

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No. INTRODUCTION The Worcester Greenskies cylinder is a Stainless Steel Unvented Twin Coil Storage vessel specifically designed to be installed in conjunction with the Worcester Greenskies solar package. Should

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION Thermostatic Mixer Shower System NOTICE The instruction manual includes part lists, installation instructions, usage of thermostatic and suitable inlet system. Make sure the installation

More information

Installation guide Sahara & Sahara Plus

Installation guide Sahara & Sahara Plus Installation guide Sahara & Sahara Plus Installation requirements. Components for Billi Sahara 310, 320, 360 & 3120 Models Before commencing installation, ensure you have identified the following. 1. Underbench

More information

Installation Instructions

Installation Instructions Installation Instructions Solar Collector Kit Solar Collector Add On Kit WARNING: Plumber Be Aware Use copper pipe ONLY. Plastic pipe MUST NOT be used. It is a requirement of a solar water heater installation

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST HOME INSPECTION CHECKLIST Date: Page 1 of 9 Client Name: Address: Tel No: Surname: Email: A WATER METER 1 Is the water meter visible YES NO 2 Water meter registers when water is drawn YES NO 3 Water meter

More information

900 Quadrant Steam Shower Cabin with 6 Body Jets

900 Quadrant Steam Shower Cabin with 6 Body Jets Product Specification Working Pressure 1.5 to 4 bar Pressure MUST be balanced Dimensions 2250 H x 900 D x 900 W Door Opening 480mm Steam Generator 2.8Kw Fuse size: 13 amp fuse spur 900 Quadrant Steam Shower

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation Issue 4 Oct 2005 Panamatic Top loading Maxi & Optima 3 Installation Please Do handle the unit with care, to avoid scuffs and scratches during installation. Do not over-tighten plumbing or any other mechanical

More information

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar SHOWER PUMPS 1.5 bar and 2.0 bar Twin and single ended pumps designed specifically for gravity feed or stored water systems where the hot water is fed from a hot water cylinder and the cold from a cold

More information

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7. Zip Econoboil Installation and Operating Instructions 301042 Zip Econoboil 1.5 litre White 303042 Zip Econoboil 3.0 litre White 305042 Zip Econoboil 5.0 litre White 307042 Zip Econoboil 7.5 litre White

More information

173 Index of Materials

173 Index of Materials 73 Index of Materials IBC Tank 9 Polystyrene Sheet 2 200 Litter Blue Barrels 0 Plumbers Tape (Teflon) 3 Fish Tank Shading Cable Ties 4 Plastic Net 2 Waterproof Eclectic Box 5 Concrete Blocks 3 0 mm Wide

More information

Funne~ Jiffy J-4000 Model Steamer FEATURES INCLUDES: From the library of: Superior Sewing Machine & Supply LLC

Funne~ Jiffy J-4000 Model Steamer FEATURES INCLUDES: From the library of: Superior Sewing Machine & Supply LLC Jiffy J-4000 Model Steamer FEATURES Built-in, easy-to-read sight gauge also indicates sediment build-up Cast aluminum housing unit for durability Corrosion-proof stainless steel boiler tank--no water lines

More information

Installation guide COMBI. Before installing read this guide first

Installation guide COMBI. Before installing read this guide first Installation guide COMBI Before installing read this guide first Introduction The operation of the Quooker COMBI The Quooker COMBI supplies boiling water via the Quooker tap and hot water via the existing

More information

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX Owner s Guide and Installation Manual 3MAVR60XX Series Fan UL Model NO. : 3MAVR60XX Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

MANUAL BIOLET. Model Separera 30 and 30 NE. What you have to know about the installation and the use of your Biolet. Websites :

MANUAL BIOLET. Model Separera 30 and 30 NE. What you have to know about the installation and the use of your Biolet. Websites : MANUAL BIOLET Model Separera 30 and 30 NE What you have to know about the installation and the use of your Biolet Websites : English : www.composttoilet.eu Dutch : www.composttoilet.be French : www.toilletteacompost.be

More information

Soak in the Sunshine. Solar Hot Water

Soak in the Sunshine. Solar Hot Water Soak in the Sunshine Solar Hot Water Soak in the sunshine, and SAVE with solar hot water from Chromagen USES UP TO 80% LESS ENERGY With a solar hot water system from Chromagen, you can literally soak in

More information

Venco 75mm (3 ) Standard and De-airing Pugmill

Venco 75mm (3 ) Standard and De-airing Pugmill Owner s manual for Venco 75mm (3 ) Standard and De-airing Pugmill Venco Products 29 Owen Road Kelmscott, Western Australia 6111 ph +61 8 9399-5265 fax +61 8 9 497 1335 email: venwest@iinet.net.au www.venco.com.au

More information

Inta City Shower Mixing Valve CT20010CP

Inta City Shower Mixing Valve CT20010CP Inta City Shower Mixing Valve CT20010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. HD 5/12 C Plus Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 1 Mobility 3 Accessory storage The integrated carrying handle on the

More information

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions Parenzo Range Basin Mixer, Bath Filler & Bath Shower Mixer Assembly instructions We have designed these products with your enjoyment in mind. To ensure that they work to their full potential, they need

More information

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX Owner s Guide and Installation Manual 5YK60XXX Series Fan CUL Model NO. : 5YK60XXX Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

TOYOTA FJ-40 DIRECTIONS

TOYOTA FJ-40 DIRECTIONS PAGE 1 TOYOTA FJ-40 DIRECTIONS Please read the following directions prior to installing this a/c system. Contact us by email or phone if you need any assistance or information regarding this a/c system.

More information

Revision 2. October Owner s Manual. Serial Number Here. Date of Purchase

Revision 2. October Owner s Manual. Serial Number Here. Date of Purchase Revision 2 October 2013 Owner s Manual Serial Number Here Date of Purchase www.batcafitness.com 1207 New Hope Road, Raleigh, NC - 919.255.1233 Omega 2 Owner s Manual - www.batcafitness.com Instructions

More information

Copper convection heaters:

Copper convection heaters: Copper convection heaters: Dual pipeline models Dual pipeline QMG models since 2009: The Run On Sun Australia copper convection heaters are manufactured to our own strict quality specifications. A pure

More information

INSTALLATION MANUAL Roof Mount Solar Hot Water System

INSTALLATION MANUAL Roof Mount Solar Hot Water System INSTALLATION MANUAL Roof Mount Solar Hot Water System Revision 3 - August 2017 CONTENTS 1... Important Information 2... Installation 3... Electrical Connections 4... Maintenance 5... Troubleshooting HOT

More information

X A M G3/4 G3/

X A M G3/4 G3/ 180 172 MAX30 2-35 43 G3/4 G3/4 209 165 ! COVER CAP MIXER HANDLE HEXAGONAL KEY SEAL CARTRIDGE MIXER BODY This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification)

More information

Antilia Wading Pool Glass Countertop Installation and User Guide

Antilia Wading Pool Glass Countertop Installation and User Guide K-2369 Antilia Wading Pool Glass Countertop Installation and User Guide MODEL NUMBERS Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the property

More information

Medi-Vac Suction and Fluid Collection Products Catalog

Medi-Vac Suction and Fluid Collection Products Catalog Medi-Vac Suction and Fluid Collection Products Catalog Guardian TM Hardware Medi-Vac Suction and Fluid Collection Products Guardian Hardware Our number one goal is to help you stay competitive in today

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

Cold water compact class HD 5/15 C

Cold water compact class HD 5/15 C Cold water compact class HD 5/15 C Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to

More information

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. all the comforts of home FEATURES SPECIFICATIONS INSTALLATION The Marine Throne "all the comforts of home" Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual

More information

U.1347LS. Perrin & Rowe Kitchen Filtered Hot Water Dispensers 2 3/8" 5 1/2" 10" 6 1/2" 3 7/8" Ø1 7/8" 1 3/4" MAX Ø1 1/4" HOLE

U.1347LS.   Perrin & Rowe Kitchen Filtered Hot Water Dispensers 2 3/8 5 1/2 10 6 1/2 3 7/8 Ø1 7/8 1 3/4 MAX Ø1 1/4 HOLE PERRIN & ROWE HOLBORN C-SPOUT HOT WATER FAUCET Perrin & Rowe Kitchen Filtered Hot Water Dispensers U.1347LS FEATURES Hot water faucet only Unique Anti-Scald lock: innovative push mechanism with exclusive

More information

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses SAAB 99 Series 1981 1984 H Type Engine Installation Guide Silicone Cooling System Hoses Classic Silicone Hoses http://www.classicsiliconehoses.com/ Disclaimer This document is for reference purposes only.

More information

Pizza Oven with Stand

Pizza Oven with Stand Pizza Oven with Stand Cooks up to 3 pizzas at a time Use to cook a variety of food Easy clean vitreous enamel interior Model No. P0104 Powerful 22MJ/h stainless steel burner Viewing window and temperature

More information

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE: INSTALLATION INSTRUCTIONS DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System Model: DORGPT-1 NOTE: This guide provides the installer with instructions specific to the Bard Double O-Ring Geo-Prime

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

Singulier Spout Tube Basin Mixer Installation and User Guide

Singulier Spout Tube Basin Mixer Installation and User Guide Singulier Spout Tube Basin Mixer Installation and User Guide MODEL NUMBERS 10862W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the property

More information

C250S (last production in 2011) 0115

C250S (last production in 2011) 0115 C250S (last production in 2011) 0115 24 toilets cassette toilets C250S (last production in 2011) 0115 Colours available 1 Pod 2 Seat 50707 30, 62 3 Cover 4 Bowl inner 5 Bowl outer 6 Overlay 50708 7 Control

More information

Click here for a labelled version of above

Click here for a labelled version of above Click here for a labelled version of above Download Of This Page: Click Here to download this whole page. (773 Kb Adobe Acrobat File) Biodiesel Processor Diagram: Click Here to download a detailed diagram

More information

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Hot Water Supply Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong E-mail: cmhui@hku.hk Feb

More information

OVSOL Solar System Manual. Solar hot water system installation guide for evacuated tube systems.

OVSOL Solar System Manual. Solar hot water system installation guide for evacuated tube systems. OVSOL Solar System Manual Solar hot water system installation guide for evacuated tube systems. table of contents System Components....................................................... 2 Introduction..............................................................

More information

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES OPERATOR S MANUAL BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SERVICE PARTS LOCATING MODEL # INFORMATION Model number and other information required for service

More information

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD Owner s Guide and Installation Manual 5COM52XXD Series Fan UL Model NO. : 5COM52XXD Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE KEEP FOR FUTURE REFERENCE SERVICE MANUAL P.O. Box 368 908 West Main Laurel, MT USA 59044 phone 800-548-7341 phone 406-628-8231 fax 406-628-8354 STOCK NUMBER 36110 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM

More information

Xpert HD Xpert HD 7140, ,

Xpert HD Xpert HD 7140, , Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL

More information

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation

More information

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Vacmobile 20/2. Instruction manual OPERATION & SERVICE This instruction manual provides general instructions for the Vacmobile 20/2 vacuum system. This machine may use either the Becker U4.20 or the PVR EM 20/B vacuum pump. Service information specific to

More information

THERMO POT MODEL: ETP-G5083(CG) Owner s Manual. For The Warranty Terms & Conditions, Please Refer To Warranty Certificate.

THERMO POT MODEL: ETP-G5083(CG) Owner s Manual. For The Warranty Terms & Conditions, Please Refer To Warranty Certificate. THERMO POT MODEL: ETP-G5083(CG) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the set. See the label

More information

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. 8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature

More information