Energy Saving & Eco-Friendly Refrigerant

Size: px
Start display at page:

Download "Energy Saving & Eco-Friendly Refrigerant"

Transcription

1 Technical Seminar Energy Saving & Eco-Friendly Refrigerant Presented By Eva Yim Business Development Director Stephen Cheung Engineering Director Date : Oct 16, 2012

2 Others 25% Lighting 15% Air Conditioning 60% Synergy s lighting solution is capable to save 50% on lighting electricity usage Synergy s A/C solution is capable to save 25% on A/C electricity usage

3 Our partners

4 Agenda Synergy Cooling Solution Case Sharing Technical Issue Q & A

5 Agenda Synergy Cooling Solution Case Sharing Technical Issue Q & A

6 Evolution in Refrigerant 1920s 1930s 2000s CFC HCFC HFC HC Non-Eco Friendly Refrigerant Eco Friendly Refrigerant Eco Friendly & Energy Saving Refrigerant Chiller R22 A/C R22 Freezer R22 /R502 Chiller R134a/R407c A/C R410a Freezer R134a/R404a/R507 Chiller Synergy Refrigerant A/C Synergy Refrigerant Freezer Synergy Refrigerant 6

7 Comparison of Refrigerant Non Eco Friendly Refrigerant CFC/HCFC Eco Friendly HFC Energy Saving Eco Friendly HC Energy Saving Energy Consumption ** - ********** 100% 100% 75% Eco Friendly - *** ********** ODP 1/0.05 0/0 0 GWP100 years 10890/ / Carbon Footprint 100% 100% 75% Harmful to Environment Banned A/C electricity remains high Super Eco Friendly Average Saving 25% 7

8 1 st Wave - Ozone Depletion CFC HCFC HFC 1979, Sept 2006, Sept 2010, Sept Data Source: NASA

9 2 nd Wave Use Low GWP refrigerants Greenhouse Gas : 56% CO2, 13% HFC / CFC Mean Surface Temp keep increasing Low GWP = GWP < 150

10 2 nd Wave Use Low GWP refrigerants Source : CIBSE National Conference 2001

11 2 nd Wave Use Low GWP refrigerants

12 Why can save energy? Weight Latent Heat Size of Particle 90% 40% 184% 50% The loading of Compressor had been reduced significantly The cooling power had been greatly increased Pressure loss had been reduced More surface area for evaporation Non-Eco CFC (R12, R22) Eco HFC (R134a, 407c, 410a) Synergy HC 12

13 Can apply in most of A/C Air Cool Chiller Split Type Water Cool Chiller Window CRAC Unit 13

14 Product Demo Synergy => w R22 => w

15 Agenda Synergy Cooling Solution Case Sharing Technical Issue Q & A

16 Synergy Cooling Reference New Treasure Centre 29.0% 29.0% % % 25.0% 21.4% 3.6% Laws Commercial Plaza 23.0% 19.0% 4.0% 38% 34.8% 21.9% 21.3% Concordia Plaza 38.0% - % 31.3% 3.5% 21.9% % % 26.5% 28.4% 25.1% 27.0% % % % - 荃豐中心 27.7% 27.7% -% 25.5% % 24.8% 24.8% % 22.3% 49.4% : Energy Saving : Temp. Saving

17 Client : Concordia Plaza Project Start : Since early 2011 Facility : York Air Cool Chiller (3,000 Tons) Refrigerant : R22 Electricity Bill in Apr, 2011 Only 16 days, saved 24% Only change 1 chiller out of 8 chillers and complete chiller installation by Apr11. The cut off of electricity bill at Apr 27 Before Installation Saving Result Annual kwh used in A/C 4,500,000 Saving % 27% After Installation In Apr, ,450 kwh $ Annual Amount Saved 1,215,000 Carbon Footprint 656,100 kg No. of Tree Saved 59,645 pcs/yr In Apr, ,583 kwh 17

18 Client : Concordia Plaza Project Start : Since early 2011 Facility : York Air Cool Chiller (3,000 Tons) Refrigerant : R22 Electricity Bill in Jul, 2012 Saved 28.3% Before Installation After Installation In Jul, ,724 kwh Saving Result Annual kwh used in A/C 4,500,000 Saving % 27% $ Annual Amount Saved 1,215,000 Carbon Footprint 656,100 kg No. of Tree Saved 59,645 pcs/yr In Jul, ,937 kwh 18

19 Case Background Customer Location : Swire : Warwick House Project Period : 12 Dec Apr 2012 Facility Test Plan : York 200 Tons Air Cool Chiller : Chiller 7 & 8 Comparison Chiller 7 (R22) Chiller 8 (Synergy)

20 The saving result Client : Warwick House (Swire Properties) Facility : York Air Cooled Recip. Chiller Saving Result Annual kwh used in A/C 3,900,000 Saving % 28.4% $ Annual Amount Saved 1,107,600 Carbon Footprint 598,104 kg No. of Tree Saved 54,373 pcs/yr 20

21 The saving result Before After Chiller 7 (R22/R22) Chiller 8 (R22/Synergy)

22

23

24 Agenda Synergy Cooling Solution Case Sharing Technical Issue Q & A

25 Any potential damage? Compatible with A/C? 25

26 Harmless to A/C Copper Pipe Compressor High Purity/Low water content No corrosion to copper Lower Pressure Reduce compressor work load prolong its lifetime Minimize leakage Had launched to market over 5 years Had installed over 10,000+ a/c system

27 Compatibility Lubricant System Material Guidelines for the use of Hydrocarbon Refrigerants in Static Refrigeration and Air Conditioning Systems from ACRIB (Air Conditioning & Refrigeration Industrial Board) 2001 Compatible with Mineral & POE Compatible with system materials such as O ring, valve seats, seals and gaskets 27

28 Precaution in Using Natural Low GWP Refrigerant

29

30 Precaution in Using Natural Low GWP Refrigerant Carbon Dioxide Ammonia Hydrocarbon Features Non Flammable Non toxic High operating pressure ODP = 0 GWP = 0 Small molecular mass Large latent heat Large vapour density Excellent heat transfer characteristics ODP = 0 Negligible GWP Compatible with copper Miscible with mineral oil Precaution Operating pressure: 80 bars Low efficiency Toxic Flammable Not compatible with copper Temperature on discharge side of compressor is higher Flammable

31 International Guideline in using Hydrocarbon EN 378 Refrigerating systems and heat pumps Safety and environmental requirements Certified Person Flammable Sign HC Accumulation Certified personnel to conduct installation Flammable point R ºC R134a 740 ºC R407c 704 ºC HC 465 ºC Oil 222 ºC Different access pattern got different charge rate control Ventilation BS EN 378-3:2008 Refrigerating systems and heat pumps. Safety and environmental requirements. Installation site and personal protection HC Flammable Window 2.1~ 9.5 % LFL Kg / m3 Practical Limit Kg/m3 State flammable sign on A/C 31

32 International Guideline in using Hydrocarbon EN 378 Refrigerating systems and heat pumps Safety and environmental requirements Roof Top Open area - No limit on charge rate Chiller Room Special Room - No limit on charge rate Ventilation will be required Office Split Type Indoor - got limit on charge rate based on different area e.g 600 sq feet - limit to 5HP / circuit Underground Underground got limit on charge rate Max 1kg (~5HP / circuit)

33 International Guideline

34 International Guideline in all types of refrigerants EN 378 Refrigerating systems and heat pumps Safety and environmental requirements Type of Refrigerant CFC HFC HC Name of Refrigerant R22 R134a/407c/410a Synergy Ventilation N : 4 air change/hr E : 15 air change/hr N : 4 air change/hr E : 15 air change/hr N : 4 air change/hr E : 15 air change/hr Flame Proof in E Fan Alarm Detector Competent Person Charge rate Different access control different charge rate

35 Comparison in MSDS amongst all types of refrigerants Type of Refrigerant CFC HFC HC Name of Refrigerant Ignition Temp 632 / 743 ºC Ventilation of workplace Stability R22 R134a/407c/410a Synergy Well-ventilated Any source of high temp, such as lighted cigarette, flames, hot spots or welding may yield toxic and/or corrosive decomposition products 468 ºC ** Flammable window 2.1 ~ 9.5% Well-ventilated Stable ** Refrigerant will mix with compressor oil when leaks, ignition temp of compressor oil at 220 ºC. Thus all CFC, HFC & HC ignition point will be lowered to 220 ºC.

36 Agenda Synergy Cooling Solution Case Sharing Technical Issue Q & A

37 PLS GO GREEN WHEN WE STILL HAVE TIME ACHIEVE SAVING WHILE USING THANY YOU

38 Thank you! Synergy Group Unit 901, AXA Centre, 151 Gloucester Road, Wanchai Hong Kong T: (852) F: (852)

Chapter 2. Alternatives to HCFCs and their Characteristics

Chapter 2. Alternatives to HCFCs and their Characteristics Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties

More information

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications. TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there

More information

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member Ammonia Refrigeration & Scenario in Industrial Refrigeration By Ramesh Paranjpey ASHRAE Fellow Life member 5 th March 2014 Basic Components Of A Refrigeration System Refrigerant Flow Path Refrigerant?

More information

Ammonia. Background on ammonia as a refrigerant

Ammonia. Background on ammonia as a refrigerant Ammonia Danfoss Industrial refrigeration has written a technical paper on things to consider when changing from HFC/HCFC s to ammonia. It outlines some of the main differences between the different plant

More information

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications: TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation

More information

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Main Anthropogenic Sources of Greenhouse Gases Refrigerants Main Anthropogenic Sources of Greenhouse Gases Refrigerants Content Refrigerant definition Refrigerants Refrigerants as a source of GHG Refrigerant Definition A refrigerant is a substance or mixture, usually

More information

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane. 1/1/12 RS-45 (R434A): Q & A 1 Q: What is RS-44? 1.Q: What is RS-45 A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-45 contain? A: RS-45 is

More information

The natural solution for domestic refrigeration

The natural solution for domestic refrigeration The natural solution for domestic refrigeration 1300 492 445 info@hychill.com.au Minus 10 is a high-purity R600a (isobutane), the dominant single-ingredient refrigerant used in state-of-the-art light commercial

More information

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22 EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22 Ameya P. Shrivastava 1, Choudhari Chandrakishor S. 2 1,2 Mechanical Department, AISSMS College of Engineering, Pune 411001, (India) ABSTRACT HCFC

More information

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-

More information

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry Journal of Physics: Conference Series PAPER OPEN ACCESS Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry To cite this article: IM

More information

Reducing Refrigerant Leakage

Reducing Refrigerant Leakage Reducing Refrigerant Leakage Mike Nankivell F.Inst.R Marketing Director Space Airconditioning plc President of HEVAC Chairman ACRIB F Gas Group An Introduction to Real Zero Information provided by Cool

More information

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU Chillers and Refrigerants APPA Institute for Facilities Management Providence, RI September, 2017 1 Purpose of Today s Presentation To provide a broad understanding of chillers and central cooling systems

More information

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration Current use of HFCs and HCFCs. Trends, alternatives and climate impact YEREVAN, Armenia, May 18-19, 2009 Didier COULOMB, Director of the IIR, d.coulomb@iifiir.org Institut du Froid (IIF) - www.iifiir.org

More information

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice. ECO Energy efficient and environmentally friendly water and space heating SANYO Air Conditioners. The natural choice. CO 2 ECO Water Heater Energy efficient and environmentally friendly water and space

More information

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008 PRICE CHOPPER SARATOGA, NY First cascade supermarket system in North America Installed and Started March of 2008 Why did we choose CO2? Meets Corporate sustainability initiatives Looking for ways to reduce

More information

Global Solutions for Ammonia Industrial Refrigeration

Global Solutions for Ammonia Industrial Refrigeration Global Solutions for Ammonia Industrial Refrigeration MAYEKAWA s lineups and results of Natural Refrigerants Atmosphere 2009 October19th 2009 Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura 1 Founded: 1924 Location:

More information

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager Gary Parker Refrigerants Product Manager Refrigerant History Status of the HCFC ( R22) Phase out Ozone Friendly Alternatives Choosing the Best Retrofit Solution Lubricants and how they impact performance

More information

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager Gary Parker Refrigerants Product Manager Refrigerant f i t History Status of the HCFC ( R22) Phase out Ozone Friendly Alternativesti Choosing the Best Retrofit Solution Lubricants and how they impact performance

More information

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options DuPont Refrigerants R22 market and the ISCEON retrofit options Airefrig November 2010 John McCormack Business Manager DuPont Chemicals and Fluoroproducts HCFC Regulations & ISCEON 3 Actions Impacting Fluorochemicals

More information

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air) FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April

More information

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17 PREPARE FOR CHANGE LOW GWP ALTERNATIVES November 17 F-GAS PHASE DOWN Where we are now F-Gas regulation places restrictions on the use of some HFC refrigerants of high GWP. This is indirectly achieved by

More information

Scroll Chillers Transition from HCFC-22 to HFCs

Scroll Chillers Transition from HCFC-22 to HFCs Scroll Chillers Transition from HCFC-22 to HFCs An HVAC Manufacturer s Perspective Todd Brown McQuay International Business Development Manager Chillers todd.brown@mcquay.com ICF Workshop, Montreal Canada,

More information

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER University of Maiduguri Faculty of Engineering Seminar Series Volume 6, december 5 ASSESSMENT OF REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R34A REFRIGERANT IN LARGE CAPACITY FREEZER S. Shodiya*, M.B. Oumarou

More information

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Acronyms you may want to know CARB California Air Resources Board GWP Global Warming Potential

More information

Natural Refrigerants.

Natural Refrigerants. Natural Refrigerants www.instituteofrefrigerationireland.ie Seamus Kerr BE, MEngSc, MIEI, MIRI seamus@rslireland.com www.instituteofrefrigerationireland.ie Reminder on terminology: CFC : R12, R502, R11

More information

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011 Natural Refrigerants: Future-proof Solutions for Today eurammon End-Users Day 2011 New Chillers for air-conditioning applications and Heat Pumps by Ir. Danny Heuvelmans, Sales Director, GEA Grasso Introduction

More information

Energy Use in Refrigeration Systems

Energy Use in Refrigeration Systems 2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is

More information

HFCs or the Old Refrigerants - what is the best Choice?

HFCs or the Old Refrigerants - what is the best Choice? HFCs or the Old Refrigerants - what is the best Choice? Hermann Halozan Institute of Thermal Engineering, Graz University of Technology Inffeldgasse 25 / B, A-8010 Graz, Austria, Phone: +43 316 873-7303

More information

A Comparison Between Refrigerants Used In Air Conditioning

A Comparison Between Refrigerants Used In Air Conditioning A Comparison Between Refrigerants Used In Air Conditioning Derya Özkan, Özden Agra and Özlem Çetin University of Yildiz Technical University, Turkey Corresponding email: tumer@yildiz.edu.tr SUMMARY It

More information

The Current Path of Refrigerants

The Current Path of Refrigerants The Current Path of Refrigerants Rick Wentling NA Market Development Manager Opteon Stationary Refrigerants November 9, 2017 Prediction is very difficult; especially if it s about the future. - Neils Bohr

More information

March 10, 2016 San Joaquin Valley RETA Meeting

March 10, 2016 San Joaquin Valley RETA Meeting March 10, 2016 San Joaquin Valley RETA Meeting Refrigerant Selection Peter Thomas, P.E., CSP Resource Compliance, Inc. Background and History Simple, dangerous Compounds Safer, more complex refrigerants

More information

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION Thomas Leck, PhD DuPont Fluorochemicals 2010 NEXT ACR Tokyo International Exchange Center 17 Feb 2010 DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

More information

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out

More information

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Material on HFC Management Fact Sheets on HFCs and Low GWP Alternatives October 205 FACT SHEET 9 Large Air-Conditioning (air-to-air). Description

More information

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications: Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Use Of Ammonia for Air Conditioning Applications

Use Of Ammonia for Air Conditioning Applications [Home] Search CD: Go Theme: Select one Issue : April-June 1999 Use Of Ammonia for Air Conditioning Applications By Ramesh Paranjpey Chief Executive Voltas - AIG Ltd., Pune Paranjpey is an M-Tech. (Refrigeration)

More information

Thermodynamics I. Refrigeration and Heat Pump Cycles

Thermodynamics I. Refrigeration and Heat Pump Cycles Thermodynamics I Refrigeration and Heat Pump Cycles Dr.-Eng. Zayed Al-Hamamre 1 Content Introduction The Reversed Carnot Cycle The Ideal Compression Refrigeration Systems Deviation from the ICRS Selection

More information

A refrigeration system for supermarkets using natural refrigerant CO 2

A refrigeration system for supermarkets using natural refrigerant CO 2 A refrigeration system for supermarkets using natural refrigerant CO 2 A. Campbell 1,2, G. G. Maidment 2 and J. F. Missenden 2 1 Tesco Stores Ltd, Shire Park, Welwyn Garden City 2 London South Bank University,

More information

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER Alka Bani Agrawal* and A.C.Tiwari 1 Department of Mechanical Engineering, R.G.T.U., Bhopal M. P. (INDIA) *E-mail : alk_agr@yahoo.co.in

More information

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Available online at   ScienceDirect. Energy Procedia 109 (2017 ) 56 63 Available online at www.sciencedirect.com ScienceDirect Energy Procedia 109 (2017 ) 56 63 International Conference on Recent Advancement in Air Conditioning and Refrigeration, RAAR 2016, 10-12 November

More information

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV ECO-FRIENDLY REFRIGERANTS Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV HISTORY OF REFRIGERATION Refrigeration relates to the cooling of air or liquids, thus providing lower temperature to preserve

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION 1 CHAPTER 1 INTRODUCTION 1.1 Background The science which deals with creating a controlled climate in indoor space is called air conditioning. Earlier days the air-conditioning was treated as a luxury,

More information

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI

More information

Low GWP alternative refrigerants to R404A

Low GWP alternative refrigerants to R404A HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,

More information

Study of R161 Refrigerant for Residential Airconditioning

Study of R161 Refrigerant for Residential Airconditioning Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 212 Study of Refrigerant for Residential Airconditioning Applications Yingwen

More information

Filter Driers with Replaceable Core

Filter Driers with Replaceable Core STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter

More information

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research Update on Next Generation Low GWP Refrigerants for Chillers Products Steve Kujak Director, Next Generation Refrigerant Research The International Symposium on New Refrigerants and Environmental Technology

More information

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment UNEP South America Regional Workshop Low-GWP, Energy-Efficient HCFC Replacement Technologies in the Refrigeration and Air Conditioning Sector Use of hydrocarbon refrigerants in commercial refrigeration

More information

Positively Innovative R32 R32. Instructions for Use and Handling

Positively Innovative R32 R32. Instructions for Use and Handling Positively Innovative R32 Refrigerants R32 Instructions for Use and Handling 2 Contents Foreword 4 1 Characteristics 5 1.1 Characteristics 5 1.2 Flammability 6 1.3 Saturated Vapor Pressure / Temperature

More information

Oyelami S., Bolaji B. O.

Oyelami S., Bolaji B. O. International Journal of Scientific & Engineering Research, Volume 6, Issue 6, June-2015 1158 Experimental Investigation of the Performance of Liquefied Petroleum Gas (LPG) Refrigerant in A Vapour Compression

More information

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration Alternatives in the AC & Chiller Sectors Sukumar Devotta and Lambert Kuijpers OORG Refrigeration 1 Outline ASHRAE position paper summary which marks a difference in the US approach dealing with various

More information

PACKAGED REFRIGERATION EQUIPMENT

PACKAGED REFRIGERATION EQUIPMENT PACKAGED REFRIGERATION EQUIPMENT BUYER S GUIDE WHAT TO LOOK FOR WHEN SELECTING LOW-CHARGE PACKAGED REFRIGERATION EQUIPMENT for your facility 2 Packaged Refrigeration Equipment Buyer s Guide What to look

More information

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

INDUSTRIAL REFRIGERATION. Position on refrigerant selection INDUSTRIAL REFRIGERATION Position on refrigerant selection 1 Which Options door do you choose today? Retrofit HFC 2 Industrial customers What is of vital importance to industrial customers? The reliability

More information

R-407A R-448A R-449A

R-407A R-448A R-449A GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants

More information

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc. A Primer on HFOs Hydrofluoro-olefins Low-GWP Refrigerants Brett Van Horn, PhD Arkema Inc. January 30, 2011 2011 ASHRAE Winter Conference Las Vegas, NV Learning Objectives for this Session Describe the

More information

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda Industry co-operation on Natural Refrigerant technology development 2014.02.04 Kenji Matsuda Copyright 2014 JRAIA About JRAIA History The Japan Refrigeration and Air Conditioning Industry Association (JRAIA)

More information

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290 hydrocarbon ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290 974280 INDEX Why R-290... 1 Best Alternative... 2-3 FAQ... 4-7 Labeling... 8-10 The Difference in R-290 vs. R-134a/R-404A... 11-17

More information

Commercial Refrigeration

Commercial Refrigeration Commercial Refrigeration A science of vague assumptions based upon debatable figures taken from inconclusive experiments performed with instruments of problematical accuracy by persons of doubtful reliability

More information

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 217 (ICMERE217) 18 2 December, 217, Chittagong, Bangladesh ICMERE217-PI-48 IR-REVERSIBILITY ANALYSIS OF A SPLIT

More information

Hydrocarbons as refrigerants

Hydrocarbons as refrigerants Hydrocarbons as refrigerants Hydrocarbons convince with their environment-friendliness and economic feasibility. A developed society cannot function without refrigeration. At home, in food production and

More information

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes Asbjørn Vonsild, Refrigerants and Standards, Danfoss Automatic Controls Brief

More information

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen COLD Basic Training Course II 1 Temperature What is cold? 2 Temperature The expression cold is not correct physically. We are talking about heat. Heat is a form of energy. Every material has got more or

More information

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81) * mayekawa, MYCOM, NewTon are registered trademarks of Mayekawa Mfg.Co.,Ltd. * Subject to change without notice. MAYEKAWA MFG. CO., LTD. 3-14-15 Botan Koto-ku, Tokyo 135-8482, JAPAN TEL:(81)-3-3642-8181

More information

Low Charge ADX Ammonia. Presented by: Bruce Nelson, President, Colmac Coil Manufacturing Rick Watters, Vice President, AMS Mechanical Systems

Low Charge ADX Ammonia. Presented by: Bruce Nelson, President, Colmac Coil Manufacturing Rick Watters, Vice President, AMS Mechanical Systems Low Charge ADX Ammonia Presented by: Bruce Nelson, President, Colmac Coil Manufacturing Rick Watters, Vice President, AMS Mechanical Systems Background Why use ammonia? It s a natural refrigerant ODP =

More information

Saving Energy and the Environment with the latest developments in Heat Pipe Technology

Saving Energy and the Environment with the latest developments in Heat Pipe Technology Continuing Professional Development (CPD) Saving Energy and the Environment with the latest developments in Heat Pipe Technology CIBSE Approved CONTENTS What is a Heat Pipe Heat Pipes for Energy Recovery

More information

Design of LPG Refrigeration System

Design of LPG Refrigeration System Design of LPG Refrigeration System Sethu Sathayan 1, Gopakumar M G 2, Jaya Krishnan S 3, Nanda Gopan 4, Nithin S 6 Assistant Professor, Department of Mechanical Engineering, SNIT Adoor, Kerala, India 1

More information

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard Opteon Refrigerants The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard Mark Hughes Business Development Manager Opteon Refrigerants Agenda Intro Chemours The Chemical

More information

Technical Information 2015/01

Technical Information 2015/01 Johnson Controls Denmark ApS Christian X's Vej 201 8270 Højbjerg Denmark Phone +45 87 36 70 00 Fax +45 87 36 70 05 www.sabroe.com CVR No 19 05 61 71 Technical Information 2015/01 14 January 2015 A newsletter

More information

10/4/2013. The Changing State of Refrigerants

10/4/2013. The Changing State of Refrigerants 10/4/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon

More information

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Seminar 34 Refrigerants Today, Tomorrow, and Beyond m Bianca W. Hydutsky, Ph.D. DuPont Chemicals & Fluoroproducts bianca.hydutsky@dupont.com Seminar 34 Refrigerants Today, Tomorrow, and Beyond Thermal Stability Studies to Evaluate Low-GWP Refrigerants 1

More information

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Comparative assessment for drop in replacement of R134a in domestic refrigerator. Comparative assessment for drop in replacement of R134a in domestic refrigerator. Pravin K. Katare Research Scholar, Department of Mechanical Engineering, G.H.Raisoni College of Engineering Digdoh Hill,

More information

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants Mukesh K. Agrawal, Dr. Ashok G. Matani Abstract- The performance of heat transfer is one of the most important research

More information

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn Sustainable Refrigerant Solutions for HVAC-R Laurent Abbas, Wissam Rached, Brett Van Horn 2014 ASHRAE Annual Conference Seattle, WA July 1, 2014 Learning Objectives 1. Design refrigeration and air-conditioning

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor(SJIF): 3.134 e-issn(o): 2348-4470 p-issn(p): 2348-6406 International Journal of Advance Engineering and Research Development Volume 02,Issue 06, JUNE -2015 COMPARATIVE

More information

Safety concerns for A2L refrigerants in AC service procedures

Safety concerns for A2L refrigerants in AC service procedures Safety concerns for A2L refrigerants in AC service procedures Alternative Refrigerants for High-Ambient Countries; Risk Assessment of Future Refrigerants in Production, Installation, and Service 28 October

More information

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE Paolo VALERO Marek ZGLICZYNSKI Embraco Europe S.r.l. Via Buttigliera 6, 10020 Riva presso Chieri (To), Italy Fax: 0039-011-9437397

More information

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP Paul Maina and Zhongjie Huan mainap@tut.ac.za and huanz@tut.ac.za Department of Mechanical Engineering, Tshwane University of Technology P.O Box Private Bag X680

More information

ENER-SAVE Hydrocarbon Refrigerants Training Manual

ENER-SAVE Hydrocarbon Refrigerants Training Manual ENER-SAVE Hydrocarbon Refrigerants Training Manual www.ener-save.biz sales@ener-save.biz FERDINAND NG ENER-SAVE SDN. BHD. Revision 26082017 All Rights Reserved ENER-SAVE Hydrocarbon Refrigerant Products:

More information

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL Second Edition STAR DISTRIBUTION CENTRES WORLDWIDE Argentina (to be opened shortly) Australia Bahrain Belgium Brazil

More information

Refrigerants Type Expensive Coefficient of Performance Toxic

Refrigerants Type Expensive Coefficient of Performance Toxic Chapter 11: Refrigeration Cycles 11.5. Selecting the Right Refrigerants When designing a refrigeration system, there are several refrigerants from which to choose, such as chlorofluorocarbons (CFCs), ammonia,

More information

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant Shubham Rangari 1, Shubham Mahakalkar 2, Shubham Tiple 3, Praharsh Marathe 4, Sameer Bansod 5, Sunnyraj Katam 6, Suraj Nagrare

More information

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS Int. J. Chem. Sci.: 14(S2), 2016, 665-674 ISSN 0972-768X www.sadgurupublications.com PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS J. THAVAMANI *, MARRIPUDAGALA KOMALI, SHAIK

More information

Natural Choice -- Ammonia

Natural Choice -- Ammonia Natural Choice -- Ammonia Ammonia is used in industrial refrigeration systems with requirements down to -50 C evaporator temperatures. However, most applications employ evaporator temperatures of -40 C

More information

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS Bernard Thonon Greth bernard.thonon@greth.fr Artificial or Natural Refrigerants? Performances COP Capacity Cost Safety Pressure, Temperature

More information

The Problem of Counterfeit Refrigerants

The Problem of Counterfeit Refrigerants The Problem of Counterfeit Refrigerants James K Carson President, Commission C2, International Institute of Refrigeration Senior Lecturer, School of Engineering, University of Waikato j.carson@waikato.ac.nz

More information

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A [1] Ranendra Roy, [2] Madhu Sruthi Emani, [3] Bijan Kumar Mandal [1], [2],[3] Department of Mechanical

More information

Trends and Perspectives in Supermarket Refrigeration

Trends and Perspectives in Supermarket Refrigeration Trends and Perspectives in Supermarket Refrigeration Prof. Dr.-Ing. Michael Kauffeld Karlsruhe University of Applied Sciences Mechanical Engineering and Mechatronics Department Institute of Refrigeration,

More information

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS COMMERCIAL REFRIGERATION RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS www.tecumseh.com Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) 1-HCFCs & HFCs Retrofit

More information

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA 5 th March 2014 Honeywell $39-39.5B in sales* 54% sales outside U.S. 1,300 sites, 70 countries 132,000 employees Morristown,

More information

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA Daniel Giguère, Technology Expert Georgi Pajani, Engineer Sophie Hosatte, Section Head, Buildings CETC-Varennes, Natural

More information

AIRAH Victoria Refrigerants Update

AIRAH Victoria Refrigerants Update AIRAH Victoria Refrigerants Update 20 th October 2014 Agenda R22 Phase down Legislation and options Interim replacements and considerations New HFO refrigerants Legislation as a driver for change New HFO

More information

R-404A Alternative with Low Compressor Discharge Temperature

R-404A Alternative with Low Compressor Discharge Temperature 2175, Page 1 R-404A Alternative with Low Compressor Discharge Temperature Barbara MINOR 1 *, Vladimir SULC 2, Jeff BERGE 3, Michal KOLDA 4, Michal HEGAR 5 1 DuPont, Fluoroproducts, Wilmington, DE, USA

More information

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants Effect of capillary diameter on the power consumption of VCRS using different refrigerants Dr. A. G. Matani 1, Mukesh K. Agrawal 2 1 Asso. Professor, Mechanical Engineering Department, Govt. College of

More information

Brazed Plate Heat Exchanger for CO Applications

Brazed Plate Heat Exchanger for CO Applications Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing

More information

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015 European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants Pune, 5 th March 2015 Mr. Marco Buoni Vice President, Air Conditioning & Refrigeration European

More information

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A ISSN: 2250-0138 (Online) NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A RANENDRA ROY a1, MADHU SRUTHI EMANI b AND BIJAN KUMAR MANDAL c abc Department

More information

A2L Refrigerants. Objectives 14/09/2017

A2L Refrigerants. Objectives 14/09/2017 A2L Refrigerants RMC HRAI Quebec City August 17, 2017 Greg Scrivener greg.scrivener@colddynamics.com Objectives 1) Learn the current state of codes and standards in relation to A2L refrigerants 2) Examine

More information