Refrigerated Air Dryer
|
|
- Pierce Dixon
- 5 years ago
- Views:
Transcription
1 Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR]) Rated inlet Outlet air pressure dew point condition MPa Refrigerant Port size Rc 3/8 Rc 1/2 R134a(HF) R407(HF) T IU FS oefficient of destruction for ozone is zero. Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (4E to 75E, 100F to 150F) Rc 3/4 Rc 1 R1 R 1 1/2 IH I R2 I I M FF M M MH ME Large size/ F Series Power supply voltage: Three-phase 380 V (50Hz) Three-phase 400 V (50Hz) Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type mbient temperature 45 at max. Inlet air temperature 60 at max. MF For sia and Oceania For Europe SF Energy saving design Exhaust heat reduced by 25% at max. mbient temperature increase suppressed. Employs a heat exchanger made of high corrosion-resistant stainless steel. Refrigerant ZF SF LL R407(HF) oefficient of destruction fro ozone is zero. 100F F F F F F-40 Rated inlet Outlet air ir flow capacity condition pressure (m3/h [NR]) dew point MPa MPa Port size R2 R 2 1/2 IN flange 80 R2 R 2 1/2 IN flange 80 89
2 INEX 1. Standard Products E Series Rated inlet condition ir flow capacity (m 3 /h [NR]) Outlet air pressure dew point Refrigerant Port size Page 3E Rc 3/8 4E Rc 1/2 6E 8E 11E 15E1 22E 37E 55E 75E MPa R134a (HF) R407 (HF) Rc 3/4 Rc 1 R 1 R 1 1 /2 R 2 P. 92 to 94 P. 95 to Large size F Series Rated inlet condition Outlet air pressure dew point ir flow capacity (m 3 /h [NR]) Port size Page 100F F F F F F MPa MPa R2 R2 1/2 IN flange 80 R2 R2 1/2 IN flange 80 P. 98 to Options Specifications pplicable model Suffix (Option symbol) ool compressed air output 3E to 11E E-23- nti-corrosive treatment 3E to 75E E F to 150F F-- With hinese labels and a hinese operation manual 3E to 75E E F to 150F F-- For medium air pressure (Up to 1.6 MPa) 6E to 37E E F to 150F F-- With heavy duty auto drain (For medium air pressure) 4E to 75E E-23-L With circuit breaker 4E to 75E E-23-R 100F to 150F F--R With terminal block for power supply, run & alarm signal and remote operation 4E to 75E E-23-T Timer type solenoid valve with auto drain (pplicable to medium air pressure) 4E to 75E E-23-V 100F to 150F F--V Page P. 101 P Optional ccessories escription ust-protecting filter set Foundation bolt set 90 Page P. 103
3 5 to Inlet air pressure (MPa) E Series Selection The corrected air flow capacity, which considers the user s operating conditions, is required for selecting the air dryer. Please select using the following procedures. However, for 400 V, model should also be selected based on the amount of processed air of 380 V regarding 100F to 150F. (orrection factor is based on the rated conditions of 380 V, so when the factor of rated conditions of 400 V is inputted, the amount of processed air of 400 V can be found.) 1 2 alculate the corrected air flow capacity. Obtain the corrected air flow capacity from the following formula. orrected air flow capacity = ir consumption (orrection factor x x ) 3 Select the model. Select the model which air flow capacity exceeds the corrected air flow capacity using the specification table. (For air flow capacity, refer to the data below.) Read the correction factor. Obtain the correction factor to suitable for your operating condition using the table below. Option Finalize the model number. Select accessories sold separately. ata : Inlet ir Temperature Inlet air temperature ( ) orrection factor 3E to 37E 55E to 75E ata : Inlet ir Pressure orrection factor 3E to 11E 15E1 to 75E Inlet air orrection factor temperature ( ) 100F to 150F 5 to Inlet air pressure (MPa) to 1.6 orrection factor 100F to 150F ondition Inlet air temperature mbient temperature Inlet air pressure ir consumption ccording to the corrected air flow capacity of 48.9 m 3 /h, the 8E will be selected when the required output air pressure dew point is 3. The 6E will be selected when the required pressure dew point is orrection factor 3E to 11E 15E1 to 75E E E E Selection Example Note) Values obtained from the table below. 100F MPa 31 m 3 /h ir flow capacity (m 3 /h [NR]) 6E E E ata symbol 8E 65 ir flow capacity (m 3 /h [NR]) 37E E 390 ir flow capacity (m 3 /h [NR]) 125F orrection factor Note) orrected air flow capacity = 31 m 3 /h (0.83 x 0.83 x 0.92) = 48.9 m 3 /h Refer to pages 101 and 102. Refer to pages 92, 95 and 98. Refer to page 103. ata : mbient Temperature mbient temperature ( ) ata : ir Flow apacity Outlet air pressure dew point mbient orrection factor temperature ( ) 100F to 150F 2 to E Note) In case of Option (ool compressed air output), the air flow capacity is different. Refer to page 101 for details. Outlet air pressure dew point Outlet air pressure dew point 75E F H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL
4 Refrigerant R134a (HF) E Series 3E, 4E, 6E, 8E, 11E, 15E (Inlet air temperature: 35 ) How to Order 8E 3E 4E 6E 8E 11E 15E1 23 Note 1) Nil L R T V Voltage Symbol Voltage 23 Single-phase 230 V (50 Hz) Note) The voltages listed below are only applicable to the 6E. Single-phase 200 V (50 Hz) 20 Single-phase 200/220 V (60 Hz) Symbol Note 2) Nil Option None 3E 4E 6E 8E 11E 15E1 ool compressed air output nticorrosive treatment With hinese labels and a hinese operation manual Options and vailable ombinations (/Option) L R T V With heavy With Timer type solenoid For medium air pressure duty auto drain With terminal valve with auto drain uto drain bowl type: (pplicable to circuit block for (pplicable to Metal bowl with level gauge medium air breaker run & alarm medium air pressure) signal pressure) Note 1) thread (PF thread) can accept the R thread (PT male thread), thus making no F in the thread specification setting. conversion hexagon nipple for the R thread (PT male thread) is also contained. Note 2) Enter alphabetically when multiple options are combined. However, the following combination cannot be achieved. ombination of, L and V cannot be achieved because an auto drain can only be attached to a single option. Note 3) Refer to pages 101 and 102 for further details on optional specifications. Note 4) Option H (uto-drain bowl type: Metal bowl) is only applicable to the 6E-20. However, options, L, and V cannot be selected in combination. 92
5 Refrigerated ir ryer E Series Standard Specifications Symbol Refrigerated air dryer uto drain Standard temperature air inlet Specifications 3E 4E 6E Note 9) 8E 11E 15E1 Fluid ompressed air Inlet air temperature Inlet air pressure mbient temperature (Humidity) ( ) (MPa) ( ) 5 to to to 40 (Relative humidity of 85% or less) Outlet air pressure dew point (3 ) Note 1) Standard condition ir flow (NR) capacity Outlet air pressure dew point (7 ) Outlet air pressure dew point (10 ) m 3 /h Note 2) ompressor Outlet air pressure dew point (3 ) intake condition Outlet air pressure dew point (7 ) Outlet air pressure dew point (10 ) Inlet air pressure Inlet air temperature mbient temperature Power supply voltage (MPa) ( ) ( ) Single-phase: 230 V [Voltage fluctuation ±10%] 50 Hz Note 6) Power consumption Note 6) Operating current (W) () Note 5) pplicable circuit breaker capacity (sensitivity current 30 m) () 5 10 ondenser Refrigerant ir-cooled R134a (HF) Refrigerant charge (kg) uto drain Port size Rc 3/8 Rc 1/2 Float type (Normally open) Rc 3/4 Rc 1 ccessory Hexagon nipple Weight (kg) ody panel: White 1 oating color ompliant standards ase: ray 2 E irective (with E marking) Note 3) Operating range Note 4) Rated specifications Electrical characteristics Note 1) ir flow capacity under the standard condition (NR) [atmospheric pressure at 20, relative humidity at 65%] Note 2) ir flow capacity converted by the compressor intake condition [atmospheric pressure at 32, relative humidity at 75%]. Note 3) The operation range does not guarantee the use with normal air flow capacity. Note 4) Please select a model in accordance with the Selection (Page 91). Note 5) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately. Note 6) These values are reference values under rated conditions, and are not guaranteed. o not use these values for the thermal set values, etc. Note 7) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns. Replacement Parts 3E uto drain replacement part no. Note 8) 4E 6E 8E 11E 15E uto drain Note 8) The part number for the auto drain components without including the body part. ody part replacement is impossible. Note 9) The specifications of the 6E-20 are the same as those of the 6E-20 (page 29) aside from the compliant standards. onstruction Principle (ir/refrigerant ircuit) Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater (heat exchanger). Water condensed at this time will be removed from the air by auto drain and drained out automatically. ir separated from the water will be heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side. 3E rain separator ompressed air inlet ompressed air outlet ooler Re-heater rain outlet Volume control valve ondenser Fan motor ompressor for Pressure switch refrigeration apillary tube Evaporation thermometer 4E, 6E 8E, 11E, 15E1 ompressed air inlet ompressed air outlet Evaporation thermometer ompressor for refrigeration rain outlet ondenser Heat exchanger rain separator apillary tube Pressure switch Fan motor ody Volume control valve 93 H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL
6 E Series 3E to 15E1 Q E M F In case of 3E L P 4 x ø13 N 4E to 15E1 Port size 3E Rc 3/8 4E Rc 1/2 6E 8E Rc 3/4 11E 15E1 Rc Meaning the foot dimensions for the 3E. E F L M N P Q
7 Refrigerant R407 (HF) E Series 22E, 37E, 55E, 75E (Inlet air temperature: 35 ) 22E 37E 55E 75E How to Order 55E 23 Symbol Note 2) Nil Option None 22E 37E 55E 75E Voltage Symbol Voltage 23 Single-phase 230 V (50 Hz) nticorrosive treatment With hinese labels and a hinese operation manual Note 1) Note 1) thread (PF thread) can accept the R thread (PT male thread), thus making no F in the thread specification setting. Note 2) Enter alphabetically when multiple options are combined. However, the following combination cannot be achieved. ombination of, L and V cannot be achieved because an auto drain can only be attached to a single option. Note 3) Refer to pages 101 and 102 for further details on optional specifications. Nil L R T V Options and vailable ombinations (/Option) L R T V With heavy With Timer type solenoid For medium air pressure duty auto drain With terminal valve with auto drain uto drain bowl type: (pplicable to circuit block for (pplicable to Metal bowl with level gauge medium air breaker run & alarm medium air pressure) signal pressure) H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL 95
8 E Series Standard Specifications Symbol Refrigerated air dryer uto drain Standard temperature air inlet Specifications 22E 37E 55E 75E Fluid ompressed air Inlet air temperature ( ) 5 to 50 Inlet air pressure (MPa) 0.15 to 1.0 mbient temperature (Humidity) ( ) 2 to 40 (Relative humidity of 85% or less) Outlet air pressure dew point (3 ) Note 1) Standard condition ir flow (NR) capacity Outlet air pressure dew point (7 ) Outlet air pressure dew point (10 ) m 3 /h Note 2) ompressor Outlet air pressure dew point (3 ) intake condition Outlet air pressure dew point (7 ) Outlet air pressure dew point (10 ) Inlet air pressure (MPa) 0.7 Inlet air temperature ( ) 35 mbient temperature ( ) 25 Power supply voltage Single-phase: 230 V [Voltage fluctuation ±10%] 50 Hz Note 6) Power consumption Note 6) Operating current (W) () Note 3) Operating range Note 4) Rated specifications Electrical characteristics pplicable circuit breaker capacity Note 5) () ondenser ir-cooled Refrigerant R407 (HF) Refrigerant charge (kg) uto drain Float type (Normally open) Port size R 1 R 1 1 /2 R 2 ccessory Weight (kg) ody panel: White 1 oating color ase: ray 2 ompliant standards E irective (with E marking) Note 1) ir flow capacity under the standard condition (NR) [atmospheric pressure at 20, relative humidity at 65%] Note 2) ir flow capacity converted by the compressor intake condition [atmospheric pressure at 32, relative humidity at 75%]. Note 3) The operation range does not guarantee the use with normal air flow capacity. Note 4) When operating conditions are different from the rated specifications, please select a model in accordance with the Selection (Page 91). Note 5) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately. Note 6) These values are reference values under rated conditions, and are not guaranteed. o not use these values for the thermal set values, etc. Note 7) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns. Replacement Parts uto drain replacement part no. Note 8) 48 22E 37E 55E 75E Note 8) The part number for the auto drain components without including the body part. ody part replacement is impossible. ody onstruction Principle (ir/refrigerant ircuit) uto drain Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater (heat exchanger). Water condensed at this time will be removed from the air by auto drain and drained out automatically. ir separated from the water will be heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side E, 37E, 55E, 75E Volume control valve ccumulator (22E, 37E, 55E only) ompressor for refrigeration Evaporation thermometer ompressed air inlet ondenser High pressure switch (55E, 75E only) all valve uto drain rain outlet apillary tube Pressure switch Fan motor ompressed air outlet ooler re-heater (Heat exchanger)
9 F Refrigerated ir ryer E Series 22E, 37E E H HW T IU FS M IH L P 4 x ø13 N I I I Port size 22E R 1 37E R 1 1 /2 290 E F L M N P Q M FF M 55E, 75E M MH R ME E Q MF ZF SF SF F LL M L P N 4 x ø13 55E 75E Port size R 2 E F L M N P Q (128) (273) (868) (110) (110) 900 (968) R
10 Refrigerant R407 (HF) 100F/125F/150F Series For use in Europe, sia and Oceania (Max. inlet air temperature: 60, Max. ambient temperature: 45 ) How to Order For use in sia and Oceania 100F F 125F 150F Voltage Symbol Voltage 38 Three-phase 380 V (50 Hz) Nil R V Option Symbol Note) escription Nil None nti-corrosive treatment for copper tube With hinese labels and a hinese operation manual Moderate pressure specification R With a circuit breaker V With a timer controlled solenoid valve type auto drain Note) Enter alphabetically when multiple options are combined. Example: When the 100F-38 is provided with options or R or V, the model number will be the 100F-38-RV. For use in Europe 100F F 125F 150F Voltage Symbol Voltage 40 Three-phase 400 V (50 Hz) Nil R V Option Symbol Note) escription Nil None nti-corrosive treatment for copper tube With hinese labels and a hinese operation manual Moderate pressure specification (1.6 MPa) R With a circuit breaker V With a timer controlled solenoid valve type auto drain Note) Enter alphabetically when multiple options are combined. Example: When the 100F-40 is provided with options or R or V, the model number will be the 100F-40-RV. 98
11 Refrigerated ir ryer 100F/125F/150F Series Standard Specifications Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) 100F/125F/150F Pressure switch High pressure switch ondensed pressure gauge Filter dryer ondenser Fan motor ir pressure gauge apillary tube Evaporation thermometer Low pressure switch ompressor for refrigeration Volume control valve ompressed air inlet ooler re-heater For use in sia and Oceania For use in Europe Specifications 100F F F F F F-40 Fluid Inlet air temperature Inlet air pressure MPa ompressed air 5 to to 1.0/0.15 to 1.6 for option mbient temperature (humidity) 2 to 45 (Relative humidity 85% or less) Standard ir flow condition capacity (NR) Note 1) ompressor m 3 /h intake Note 2) condition Inlet air pressure MPa 0.7 Inlet air temperature mbient temperature Outlet air pressure dew point 10 3 Power supply voltage Three-phase 380 V Three-phase 400 V Operating range Note 3) Rated conditions Electric specifications Power consumption Operating current pplicable circuit breaker capacity Note 4) Heat discharge from condenser Refrigerant Refrigerant charge uto drain Port size Weight oating color ompliant standards Replacement Parts ir dryer model 100F Heavy duty auto drain replacement part no. Note 5) ustproof filter set for condenser Note 5) Part number of only the exhaust mechanism replacement kit excluding the housing rain outlet ompressed air outlet Secondary heater all valve uto drain kw kw kg kg R407 (HF) Float type (Normally open) The option V stands for a timer type solenoid valve. R2 R2 1/2 IN flange 80 R2 R2 1/2 IN flange ody panel: White 1 ase: ray 2 E irective compliant (with E marking) -FL F H-E F -FL Note 1) ir flow capacity under the standard condition (NR) [atmospheric pressure 20, relative humidity 65%] Note 2) ir flow capacity converted by the compressor intake condition [atmospheric pressure 32 ] Note 3) The operation range does not guarantee the use with normal air flow capacity. When operating conditions are different from the rated specifications, please select a model in accordance with Selection (page 91). Note 4) Install a circuit breaker with a sensitivity 30 m. Exhaust mechanism replacement kit Housing (Use existing equipment.) Hot and humid air entering the air dryer is cooled down by the cooler re-heater (heat exchanger). The moisture which is condensed and separated is automatically exhausted by the auto drain. The air which has had its moisture removed is heated in two stages by the re-heater (heat exchanger) in the cooler re-heater and by the secondary heater, and is supplied to the outlet side as warm and dry air. Secondary heater ompressed air from which drainage has been exhausted exchanges heat with refrigerant which has been compressed by the refrigerator, to give the following effects: 1. The outlet air temperature increases, preventing condensation of the piping on the outlet side. 2. The amount of heat exhausted from the condenser is reduced. 3. Energy saving operation of the dryer is achieved by reducing the amount of heat exhausted from the condenser. 99 H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL
12 F 100F/125F/150F Series 100F/125F 10 note) E F P L N M Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm. 100F 125F Port size R2 R2 1/ E F L 712 M N P F E 10 note) P L N M Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm. Port size 150F IN flange E 720 F L 990 M 217 N 935 P 1030
13 E/F Series Options 1 For How to Order optional models, refer to pages 92, 95 and 98. Option symbol ool compressed air output There is no heating of cooled, dehumidified air as it leaves the air dryer. The air flow capacity with this option is smaller than that of the standard dryer. (The external dimensions are identical with the standard product.) Note) Perform thermal insulation treatment for piping and equipment installed after the dryer to prevent the formation of condensation. ir Flow apacity 3E 4E 6E 8E 11E ir flow capacity m 3 /h (NR) onditions: Inlet air pressure: 0.7 MPa, Inlet air temperature: 35, Outlet air temperature: 10 mbient temperature: 25 Option symbol nti-corrosive treatment This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. (orrosion cannot be completely prevented.) Special epoxy coating: opper tube and copper alloy parts. The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by the coating. orrosion is not covered under warranty. Option symbol With hinese labels and a hinese operation manual In addition, hinese labels are put on the external panels. hinese operation manual is also included. Option symbol Moderate pressure specification uto drain bowl type: Metal bowl with level gauge Option symbol 100F Moderate pressure specification The maximum operating pressure is 1.6 MPa. The internal drain piping material is changed from nylon to metal. Specifications 1. Maximum operating pressure: 1.6 MPa 2. same as standard products 3E to 11E all models The auto drain is changed from the standard one to one with a moderate pressure specification. metal bowl with a level gauge which can confirm the water level is used for the auto drain. Specifications 1. Maximum operating pressure: 1.6 MPa 2. same as standard products all models 6E to 37E Replacement Parts 6E to 15E1 uto drain assembly part no. -S0086 Note The 48-8-X2110 auto drain, insulator, and One-touch fitting are included. 22E, 37E 48-8-X2110 Single auto drain unit to 150F L Option symbol With heavy duty auto drain (pplicable to moderate air pressure) The float type auto drain used in the standard air dryer is replaced with a heavy duty auto drain (H ) which enables the drainage to discharge more efficiently. 4E to 15E 22E to 75E all valve 4E 6E 8E, 11E 15E1 4E to 75E Heavy duty auto drain 22E, 37E pprox E, 75E pprox. 120 Note 1) The heavy duty auto drain and the ball valve are both enclosed in the same shipping package as the main body of the air dryer. ustomers are required to mount the parts to the air dryer. (Except 22E to 75E) Note 2) ustomers will need to supply the fitting and tubing for the drain piping. (Except 22E to 75E) Replacement Parts: Heavy uty uto rain rain outlet Rc 1/2 4E to 15E1 22E to 75E (207) (157) () all valve Heavy duty auto drain rain tube: Length approx m (O.. ø10) Replacement part no. (escription) H (Heavy duty auto drain) H-E400 (Replacement kit for exhaust mechanism) onfiguration Heavy duty auto drain Replacement kit for exhaust mechanism Housing (You don t need to purchase a new housing.) H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL 101
14 E/F Series Options 2 For How to Order optional models, refer to pages 92, 95 and 98. R Option symbol With circuit breaker circuit breaker with cover is attached to the side of the air dryer. This saves additional electrical wiring at the time of installation. 4E to 15E1 4E, 6E, 8E, 11E 15E1 60 E E to 75E, 100F to 150F 40 ircuit breaker Power cable outlet (ø17) rommet with membrane E T Option symbol With terminal block for power supply, run & alarm signal and remote operation In addition to the terminals for the power supply, terminals for the operating signal and the error signal are also available. (No-voltage contact) lso, in the case of remote control, operate it from the power supply side while the air dryer switch remains ON. ontact capacity: 230 V, 4 24 V, 5 for operating and error signals. Minimum current value: 20 V, 5 m (/) for operating and error signals. Note 1) Terminal block for power supply, run & alarm signal and remote operation is mounted on the standard types of the 100F to 150F. Note 2) Please be sure to confirm the electric circuits with the drawings or instruction manual before using the output signal. 4E to 15E1 Terminal block 4E to 75E Signal cable outlet (ø17) rommet with membrane 22E to 75E E ircuit breaker 4E, 6E, 8E, 11E 15E1 Power cable outlet (ø17) rommet with membrane Power cable outlet (ø17) (Wire diameter ø9 to 11) F 22E to 75E 22E 37E 55E 75E F to 150F E F Power cable outlet (ø17) (Wire diameter ø9 to 11) Signal cable outlet (Wire diameter ø17) rommet with membrane Terminal block Voltage 230 V type 380/400 V type 100F 125F 150F reaker apacity and Sensitivity urrent 102 4E-23, 6E-23 8E-23, 11E-23 15E1-23, 22E-23 37E-23, 55E-23 75E F, 125F 150F reaker capacity Sensitivity current 30 m 22E, 37E 55E, 75E V Option symbol Timer type solenoid valve with auto drain (pplicable to medium air pressure) E to 75E 100F to 150F rainage is discharged by controlling a solenoid valve with a timer. strainer for solenoid valve protection and stop valve are also included. ( are the same as the standard type.) Maximum operating pressure: 1.6 MPa (100F to 150F: 1.0 MPa) The timer-type solenoid valve actuates once (for 0.5 s) every 30 s. Replacement Parts Part no. Note 4E to 37E -S V 55E, 75E -S V 100F to 150F -S V
15 E/F Series Optional ccessories ust-protecting filter set Foundation bolt set How to Order ust-protecting filter set FL 209 pplicable dryer Symbol pplicable dryer 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ust-protecting Filter Set/ Features Prevents a decline in the performance of the air dryer, even in a dusty atmosphere. olts for fixing the air dryer to the foundations. Easy to secure by striking its axle. Foundation bolt set (-FL209) (-FL202 to 208, 213, 214) Foundation olt Set/ Part no pplicable dryer 4E to 75E 100F to 150F 500 (20) Nominal thread size pplicable dryer Symbol Material pplicable dryer 4E to 75E 100F to 150F (20) (10) Pcs. of 1 set M10 Stainless steel 4 Specifications Max. ambient temperature 40 Stainless steel pplicable dryer 3E to 75E 4E to 75E 100F to 150F Part no. pplicable dryer Weight (g) -FL209 3E FL202 4E FL203 6E FL204 8E FL205 11E FL206 -FL207 -FL208 -FL213 -FL214 15E1 22E 37E 55E 75E H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL Mounting hole diameter: ø
16 E/F Series Specific Product Precautions 1 e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 6 to 8 for ir Preparation Equipment Precautions. aution Installation void locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is greater than 85%) void exposure to direct sunlight. void locations that contain much dust, corrosive gases, or flammable gases. Failure due to corrosion is not covered under warranty. However, when the risk of corrosion is high, select Option (copper tubing with anti-corrosive treatment). void locations of poor ventilation and high temperature. void too close to a wall etc. Leave sufficient room between the dryer and the wall according to the Maintenance space in the operation manual. void locations where a dryer could draw in high temperature air that is discharged from an air compressor or other dryer. aution ir Piping e careful to avoid an error in connecting the air piping at the compressed air inlet (IN) and outlet (OUT). Install by-pass piping since it is needed for maintenance. 3E ompressed air inlet ompressed air outlet Valve closed Valve open 4E to 15E1 ompressed air inlet ompressed air outlet Valve closed The air exhaust should not flow into the neighboring equipment. (Top side) void locations subjected to vibration. void possible locations where the drain can freeze. Use the air dryer with an ambient temperature lower than 40. void installation on machines for transporting, such as trucks, ships, etc. void locations which experience sudden pressure/flow rate changes. aution rain Tube polyurethane tube is attached as a drain tube for the 3E to 75E and 100F to 150F. Use this tube to discharge drainage. o not use the drain tube in an upward direction. o not bend or crush the drain tube. (Operation of the auto drain will stop water vapor from discharging through the air outlet.) If it is unavoidable that the tube goes upwards, make sure it only goes as far as the position of the auto drain. 22E, 37E ompressed air outlet Valve open Valve open ompressed air inlet Valve closed aution Power Supply onnect the power supply to the terminal block. Install a suitable circuit breaker applicable for the specific model. The voltage fluctuation should be maintained within ±10% of the rated voltage. Note) Select a circuit breaker with a sensitivity current 30 m. s regards rated current, refer to pplicable circuit breaker capacity on pages 93, 96 and
17 E/F Series Specific Product Precautions 2 e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 6 to 8 for ir Preparation Equipment Precautions. aution 55E, 75E aution ir Piping ompressed air outlet Valve closed Protection ircuit ompressed air inlet Valve open When tightening piping at the air inlet/outlet tube, the hexagonal parts of the port on the air dryer side or piping should be held firmly with a spanner or adjustable angle wrench. Variations in operating conditions may cause condensation to form at the surface of the outlet piping. pply thermal insulation around the piping to prevent condensation from forming. Vibration resulting from the compressor should not be transmitted through air piping to the air dryer. o not allow the weight of the piping to lie directly on the air dryer. If a metallic flexible tubing is used for the inlet/outlet air piping, abnormal noise might be generated in the piping. In that case, please change it to the rigid tubing. When the air dryer is operated under the following stated conditions, a protection circuit is activated, the light turns off and operation stops. When the compressed air temperature is too high. When the compressed air flow rate is too high. When the ambient temperature is too high. (40 or higher, however, 45 or higher for 100F to 150F) When the fluctuation of the power supply is beyond the rated voltage ±10%. When the dryer is drawing in high temperature air that is discharged from an air compressor or other dryer. The ventilation port is obstructed by a wall or clogged with dust. ompressor ir elivery aution Use an air compressor with an air delivery of 100 L/min or larger with the 3E to 75E series. Since the auto drain of the 3E to 75E is designed in such a way that the valve remains open unless the air pressure rises to 0.15 MPa or higher (0.05 MPa or more for 100F to 150F), air will blow out from the drain discharge port at the time of air compressor start-up until the pressure increases. Therefore, if an air compressor has a small air delivery, the pressure may not be sufficient. aution uto rain The auto drain may not function properly, depending on the quality of the compressed air. heck the operation once a day. aution leaning of Ventilation rea Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle. aution elay for Restarting llow at least three minutes before restarting the dryer. If the air dryer is restarted within three minutes after being stopped, the protection circuit will be activated, operating light turns off and the dryer will not be activated. The residual drainage in the air dryer may splash over the outlet when the operation is re-started, so it is recommended to install a filter on the outlet of the air dryer. Modifying the Standard Specifications aution o not modify the standard product using any of the optional specifications once the product has been supplied to a customer. heck the specifications carefully before selecting an air dryer. H HW T IU FS IH I I I M FF M M MH ME MF ZF SF SF LL 105
18 E/F Series Specific Product Precautions 3 e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 6 to 8 for ir Preparation Equipment Precautions. M Refrigerant with WP reference Refrigerant lobal warming potential (WP) Regulation (EU) No 517/2014 (ased on the IP R4) Revised Fluorocarbons Recovery and estruction Law (Japanese low) R134a 1,430 1,430 R404 3,922 3,920 R407 1,774 1,770 R410 2,088 2,090 Note 1) This product is hermetically sealed and contains fluorinated greenhouse gases (HF). When this product is sold on the market in the EU after January 1, 2017, it needs to be compliant with the quota system of the F-as Regulation in the EU. Note 2) See specification table for refrigerant used in the product. 106
Refrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryers
Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic
More information120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V
More informationRefrigerated Air Dryers
Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryer
T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationRefrigerated Air Dryer Large Size Series
Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)
More information% by up ctoond re-heater and
Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA
More informationIDU22C, 22C1, 37C, 37C1, 55C, 75C
Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port
More informationRefrigerated Air Dryer
Refrigerated Air Dryer Large Size Series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 Inlet air temperature 60 Energy
More informationRefrigerated Air Dryer
Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3
More informationRefrigerated Air Dryer Large Size Series
ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Refrigerated ir Dryer Large Size Series IDF25F/50F are added! New Model IDF00F- IDF00F--W
More informationRefrigerated Air Dryer
Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,
More informationRefrigerated Air Dryer
Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet
More informationWith air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed.
Thermo-dryer With air temperature adjustment function New RoHS Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed air with the same conditions and quality
More informationMembrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification
Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting
More informationPrevents condensation
Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationDrain Separator for Vacuum
Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port
More informationCost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.
Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate
More informationAOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO
AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION
More informationRefrigeration air dryer
Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationCKD refrigerating type dryer
CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type
More informationFilter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl
More informationReducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display
More informationAMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications
Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the
More informationPathfinder Air-Cooled Single-Screw Chiller/Heat Pump
Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min
More informationPURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)
PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet
More informationOutstanding Performance; Application Flexibility
PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote
More informationIndustrial cooling solutions
Industrial cooling solutions Protect the Environment and your Investments The use of chilled water is essential in many industrial production and transformation processes. The range of needs varies from
More informationTUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features 197 Safety Precautions 199 Secondary Air Flow Rate, Secondary Air Dew Point, and Pressure Drop 201
More informationVRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT
Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related
More informationCost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow
More informationAir-Conditioners PUHZ-RP HA2
ir-onditioners PUHZ-RP H2 INSTLLTION MNUL FOR INSTLLR For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. nglish ontents
More information30RB /30RQ
AIR-OOLE LIQUI HILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-IALOG PLUS * Unit with low noise option 30RB9-80/30RQ0-46 Refrigerant HF-40A Nominal cooling capacity 93-78 kw Nominal heating capacity 7-0 kw
More informationMOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB
MOBILE AIR CONDITIONER User Manual PC15/20/26-BCB VERY IMPORTANT Please read this instruction guide before install and using your mini portable type air conditioner unit. This instruction manual is the
More informationMEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,
More information±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions
Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Standard Type ±.1 C New HRS5 New HRS6 (UL Standards) RoHS HRS12/18/24 New HRS3 Same width for all models:
More informationusing heat exhausted by refrigerating circuit.
Circulating Fluid Temperature Controller Thermo-chiller No heater required, circulating fluid is heated using heat exhausted by refrigerating circuit. Circulating fluid temperature [ F] Cooling capacity
More informationInstaller manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50
-30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationSplit-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English
Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS
More informationAir-Conditioners OUTDOOR UNIT MXZ-8C140/160VAMD-A
ir-onditioners OUTOO UNIT MXZ-8140/160VM- HF utilized 410 INSTLLTION MNUL FO INSTLLE For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationHigh efficiency compressed air filtration. Truly Innovative Compressed Air Purification. LF Series
01 AU High efficiency compressed air filtration Truly Innovative ompressed Air Purification LF Series LF Series Filters A filter range you can trust Protect your equipment while saving money The reliability
More informationPressure Switches Precautions 1 Be sure to read this before handling.
Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate
More informationAir-Conditioners PUHZ-RP HA5 PUHZ-RP KA2
ir-onditioners PUHZ-RP H5 PUHZ-RP K2 INSTLLTI MNUL FOR INSTLLER For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit.
More informationSplit-type Air-Conditioner
Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of
More informationUSER MANUAL TPS-M5/M55/M555
VERY IMPORTANT Please read this instruction guide before install and using your mini portable type air conditioner unit. This instruction manual is the universal-purpose version for the units that you
More informationAir-Conditioners OUTDOOR UNIT MXZ-8B140,160VA-A
ir-onditioners OUTOO UNIT MXZ-8140,160V- HF utilized 410 INSTLLTION MNUL FO INSTLLE For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
More informationINSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )
SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationINSTALLATION &OPERATIONS MANUAL
LOW AN ULL INSTALLATION &OPERATIONS MANUAL MOBILE ROOM AIR ONDITIONER OR UTURE REERENE ONTENTS Safety Precaution... 1 Parts Description... 4 ontrol Panel... 5 Operation... 6 Accessories... 7 Installation...
More informationWaterproof Circular Connectors
Waterproof ircular onnectors JR-W Series Product Specifications Ratings Ratings Ratings urrent rating Voltage rating Operating temperature range Storage temperature range Shell size urrent rating 13 16
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationTechnical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.
anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................
More informationAir Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003
ir onditioning & Refrigeration Master atalog atalog I-2003-1/US pril 2003 Table of ontents Table of ontents Introduction to Parker... page 77 System 5400 Series Self-Sealing Steel... page 78 5500 Series
More informationWFH Series. High Efficiency Filters
WFH Series High Efficiency Filters Save Energy Dollars Protect Your Air System Your compressed air is contaminated! Airborne water vapor and dust are drawn into your compressor intake. The compressor adds
More informationRefrigerated Compressed Air Dryer
Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED
More informationPAC-AH10A-G. Air Handling Unit Controller INSTALLATION MANUAL FOR INSTALLER
ir Handling Unit ontroller P-H10- OR NSTLLR NSTLLTON MNUL or safe and correct use, please read this installation manual thoroughly before installing the controller. 2 [ig. 2.0.1] 1 2 3 4 5 6 7 1 ontroller
More informationPrevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK
Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do
More informationMODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS
MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationGUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.
Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationHollow Fiber Membrane Filter Type Air Drier Unit Type
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Drier Unit Type Dry Unit 202 No electric power supply is required. Air Filter, Mist
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationBrazed Plate Heat Exchanger Instruction Manual for BX Series
Brazed Plate Heat Exchanger Instruction Manual for BX Series Thank you very much for purchasing the Hisaka Brazed Plate Heat Exchanger. Read carefully this instruction manual to use the heat exchanger
More informationRoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W
New Circulating Fluid Temperature Controller Thermo-chiller (UL Standards) Compact Type RoHS HRG(C)5 (Existing model) Compact Space-saving HRS5 976 Ve 615 n tio 592 5 377 377 (mm) (mm) Lightweight 4 kg
More informationRotary Screw Compressors BSD/CSD/CSDX T SFC Series
Rotary Screw ompressors SD/SD/SDX T SF Series With the world-renowned SIGM PROFILE ir deliveries from 0.87 to 5.85 m /min, Pressures 5.5 to 5 What do you look for in a compressor with variable frequency
More informationAIR CONDITIONER CASSETTE
Installation manual AIR CONDITIONER CASSETTE English 10. REFRIGERANT TUBING...17 11. PANEL INSTALLING...19 12. FINAL TASKS...21 1 1. REQUIRED TOOLS FOR INSTALLATION WORK 2. SAFETY PRECAUTIONS Installation
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationCompressed air preparation Compressed air storage Moisture management. Catalog #1
Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.
More informationAir-Conditioners PUZ-A NHA, PUZ-A NHA-BS PUY-A NHA, PUY-A NHA-BS
ir-onditioners PUZ- NH, PUZ- NH-S PUY- NH, PUY- NH-S nglish eutsch Nederlands spañol Italiano ÏÏËÓÈÎ Português ansk Svenska INSTLLTION MNUL For safe and correct use, read this manual and the indoor unit
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More information1998 Expedition/Navigator Workshop Manual
Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:
More informationHOT WATER SYSTEMS.
HOT WATER SYSTEMS www.thermann.com.au GAS STORAGE HOT WATER SYSTEM The Thermann 4* Gas hot water heater can suit any family type. With an adjustable thermostat for safety and efficiency it allows you to
More informationOPERATING INSTRUCTIONS
EN DEHUMIDIFIER LILIUM 11 LILIUM 13 OPERATING INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions
More informationBe sustainable while protecting your business
Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair
More informationSplit-type Air-Conditioner
Split-type Air-Conditioner MXZ-2E52VAD MXZ-3E54VAD MXZ-4E71VAD Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the
More informationAIR CONDITIONER FLOOR CEILING
Installation manual ENGLISH AIR CONDITIONER FLOOR CEILING English Indoor unit floor ceiling type FCD / TCD /DCF IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES.
More informationSERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2
Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models
More informationCondensate Drain Valves
Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions
More informationSplit-type Air-Conditioner
Split-type Air-Conditioner MXZ-2C52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of
More informationPORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.
PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the
More informationWINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL
MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or
More informationDEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST
COMFORT...BUILT TO LAST 11 PINT DEHUMIDIFIER USER MANUAL FOR MODEL: 3PAD11 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt. CONTENTS
More informationHollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting
http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type
More informationAdsorption Dryers. AD 7 to 1300
D dsorption Dryers D 7 to 300 LUP Driven by technology. Designed by experience. lup Kompressoren has over 85 years of industrial experience. It is our ambition to offer compressed air solutions that ensure
More informationPC20-AMFII / PC40-AMF USER MANUAL
VERY IMPORTANT PC20-AMFII / PC40-AMF USER MANUAL Please read this instruction guide before install and using your portable air conditioner unit. This instruction manual is the universal-purpose version
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationUSER MANUAL SILENT16 PORTABLE AIR CONDITIONER
USER MANUAL SILENT16 PORTABLE AIR CONDITIONER Thank you for choosing electriq Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More information