1 grundfos grundfos category INDUSTRY heading Boiler Feed Manual The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide Grundfos Holding A/S Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel:

2 grundfos ENGINEERING MANUAL ENGINEERING MANUAL Copyright 2012 GRUNDFOS A/S. All rights reserved. Copyright law and international treaties protect this material. No part of this material may be reproduced in any form or by any means without prior written permission from GRUNDFOS Holding A/S. All reasonable care has been taken to ensure the accuracy of the contents of this material: However, GRUNDFOS shall not be held liable for any losses whether direct or indirect, incidental or consequential arising out of the use of or reliance upon on any content of this material. 2

3 grundfos table of contents General...6 Boiler types...6 Hot water boiler...7 Thermal oil boiler...7 Steam boiler... 8 Steam generator... 8 Exhaust gas boiler... 9 Boiler house components...10 Deaerator...10 Condenser Economizer Hot-well...14 Make-up water...18 Level control valve and actuators...19 Boiler systems...21 Pumps Hot water boiler On/off shunt pump Shunt pump with variable speed Steam boiler...23 On/off control...23 Through feed valve Through feed valve and variable speed...25 Variable speed Condensate system Feed water Pump sizing...35 Grundfos solutions...41 Theory/Problems FAQ...55 Certificates:

4 grundfos boiler types General Fig. 1: A typical boiler construction in the manufacturing industry Hot water boiler Hot water boilers are normally used in room and The production of steam and hot water is one of the building heating. These kinds of systems are suitable world s largest industries. Grundfos is pleased to be for discharge temperatures of up to 140 C. The advan- the preferred supplier of pumps for boiler systems for tage of hot water over steam is that the energy loss is these industries. much lower than with steam boilers. Fig. 4 shows how Grundfos pumps are reliable, efficient and cover the pumps are normally installed in a hot water boiler. a wide performance range. As an experienced consultant in the implementation of boiler systems, we engage in the process of close partnership and dialogue to find the best solution for your system. Grundfos is a global enterprise with a worldwide Fig. 4 Hot water boiler discharge End service network. When you need export or on-thespot advice in a particular part of the world, we have the technical expertise close by. Fig. 2: This construction is typically seen in marine, but is also used in manufacturing industry Burner Shunt Boiler types Return Five main boiler types exist: Thermal oil boiler Hot water boiler In hot oil boilers, oil is used instead of steam or water. Thermal oil boiler The advantage of oil is that the system does not Steam boiler have to be pressurised above 100 C as with water Steam generator and steam. Thermal oil is still liquid in atmospheric Exhaust gas boiler pressures of up to 300 C. In contrast, water requires a pressure of 85 bar to avoid evaporating at that The demands and the sizing of the pumps used for temperature. The construction of thermal oil boilers these boiler types are very different. and piping systems is almost identical to that of hot Fig. 1 and 2 on the right show some of the typical water boilers. So where the unique features of steam boiler constructions used. Fig. 3 is a cut-open drawing of the most common construction of a boiler used in the manufacturing industry. At the bottom the burner chambers are seen, which are surrounded with water and at the Fig. 3: The most common construction of a boiler used in the manufacturing industry are not required, thermal oil can be a good alternative. Fig. 5 Hot water boiler discharge End top the smoke pipes. On the side of the boiler the two feed water pumps are seen. Burner Shunt Return 6 7

5 grundfos boiler types Steam boiler Steam is normally used in industrial process heating due to its high energy content. Steam is also used for cleaning applications and turbine operation. The advantage of steam over hot water is its high energy content and ability to release energy during condensation. This also allows for very small heat exchangers. And of course when talking sterilisation it is unique. Fig. 6 pressure vessel). Thus there is no buffer in a steam generator, and is it temporary overloaded, i.e. beyond its nominal steam capacity - a separate buffer tank should be provided. On Fig. 7 is shown a steam generator for the pharmaceutical industry where clean steam out of WFI water (WFI = Water for Injection) is produced. The WFI water is being heated by traditional steam. The advantages using a steam generator compared to conventional steam boilers: Fig. 7: Steam generator Easy to operate - normally no requirement for boiler authorisation Rapid start-up and establishing full steam pressure Compact and easy to adapt in the existing machinery arrangement Price attractive - especially at low steam rates. Exhaust gas boiler Steam can be produced not only by oil or gas-fired burners, but also by utilising the substantial amount of waste heat in hot flue gasses or exhaust air. The steam evapouration is done like the steam generators, and gives therefore a rapid acting and compact unit. Fig. 8: Exhaust gas boiler Steam generator In the steam generator, the feed water and steam are in principle passing through one long tube - designed as winded-up tube coils serially connected. In this long tube (tube coils), the feed water is heated up to the evaporation temperature in the first part and then evaporated in the second part. The intensity of the heat, the feed water flow and the size/length of the tube are adapted, so that the water is exactly fully evaporated at the exit of the tube. This ensures a very small water and steam volume (content of the Utilisation of the waste heat in flue gas of the steam boiler / steam generator itself, is called either an economizer or an exhaust gas boiler. It can be used for preheating the feed water, but also for external purposes including preheating of make-up water, domestic water or central heating water. 8 9

6 grundfos boiler house components Boiler house components Deaerator Deaerator and condenser tanks are only used in steam boiler systems and not in hot water and hot oil boilers as fluid is always in its liquid form. The construction of these two types of tanks is almost identical, but as their names indicate, they are used for different purposes. Deaerator The most important task for the deaerator is to reduce the oxygen (O 2 ) and carbonic acid (H 2 CO 3 ) levels in boiler feed water to protect the boiler against corrosion. It is possible to reduce the oxygen and carbonic acid levels to approx. < 0.02 mg/l of O 2 and 0 mg/l of CO 2, depending on the deaerator construction. Fig. 9: Deaerator Air vent Two primary principles are used with this form of tank design; thermal and vacuum. The tank design used depends on the type of boiler being used. Each principle also has different pump construction requirements. Thermal principle A tank using the thermal principle is connected to the atmosphere. This design is normally used in smaller plants. Here, steam is used to maintain the tank water temperature at around 105 C, which removes air from the water. The air vent valve mounted on the Deaerator or condenser needs an opening pressure of approx. 0.2 bar. This provides a total pressure of 1.2 bar absolute. This means that the water will boil at a temperature higher than the usual 100 C which is the normal boiling temperature in atmospheric pressure. See also the vapour pressure table at the back of this manual. Besides the air vent valve, a vacuum breaker valve has also been mounted to ensure that vacuum never occurs in this tank type. If the vacuum valve was not mounted, vacuum could occur when cold make-up water was added to the tank. Vacuum principle Here an ejector pump is used to create a vacuum in the tank. This causes the water to start boiling even at lower temperature than typical 60 C. This in turn removes air from the water. This principle is normally used in steam turbine applications. Glass level gauge Vent Drain Trayed section Rollers Liquid level Internal steam distributor piping Internal perforated pipe (water distributor) Perforated trays Low pressure steam Boiler feed water (Recycled condensate and make-up water) Over the last years it has become more and more normal just to use hot wells or water tanks with a water temperature of approx. 80 C instead of the deareators to get the oxygen out of the water. Instead of boiling the water in these tanks chemicals are dosed to remove the oxygen. Condensate Deaerator Aeration steam Deaerated water to boiler feed water pump Feed tank Heating steam 10 11

7 grundfos boiler house components Condenser A condenser ensures that all steam is condensed before being pumped back into the deaerator and then into the boiler. New treated water is normally fed into the condenser. Fig. 11 exhaust to funnel Fig. 10: Condenser Condensate Economizer Deaerator Water outlet Steam To ejector vacuum system Baffle Baffle Flanges exhaust from main engine Steam Boiler Burner Flanged cover plate Tube sheet Baffle Tube sheet Fig. 12 Feed pump Water inlet Condensate Economizer As mentioned earlier, the economizer is more or less the Condensate same as an exhaust gas boiler except it doesn t have its own steam chamber but uses the one in the boiler. Talking economizers, there are normally two Deaerator exhaust to funnel different ways of mounting depending whether it is installed on a land-based or marine-based boiler. Steam On the boiler located on land we use the boiler s flue Boiler gas as shown on the sketch. The water circulated Economizer above the economizer is normally supplied by the main feed pump, but can also be fitted with its own Burner circulation pump, see Fig. 11 on the following page. The chimney will also include a bypass to allow waste Feed pump Circulation gases to pass the heat exchanger. exhaust from main engine 12 13

8 grundfos boiler house components The economizer on marine boilers differs from the land-based boilers because it is installed in the funnel on the main engine as waste gases released from that source are significantly greater. Energy produced by marine applications often allows for the generation of overheated steam fed directly from economizer and out into the piping. Referring to the illustration in Fig. 12, the circulation pump has to be sized to the pressure and temperature in the boiler, which may easily be 20 bar and 170 C. Because of this, pumps featuring air-cooled top and bearing flange may be required. The pump does not normally need to be capable of delivering a high differential pressure as it only has to overcome the pressure loss in the pipe heat exchanger (the economizer). When installing an economizer it is very important to monitor, that the flue gas temperature in the economizer, ducts or chimney does not drop below the dew point temperature. If the flue gas condensates and the fuel contained any substances that turn into acids, the condensate will become very aggressive and possibly corrode the parts in contact. If condensation of flue gases is desired in order to reach higher thermal efficiency, please take contact to the fuel supplier for chemical analysis, and select materials for the parts, that can handle the acids. both, together with flash steam from the blow down system, flow through sparge pipes installed well below the water surface in the feed water tank. The sparge pipes must be made from stainless steel and be adequately supported. Operating temperature It is important that the water in the feed tank is kept at a sufficiently high temperature to minimise the content of dissolved oxygen and other gases. The correlation between the water temperature and its oxygen content in a feed tank can be seen in Fig. 13. Fig. 13: Water temperature versus oxygen content Oxygen content [ppm] Water temperature (oc) If a high proportion of make-up water is used, heating the feed water can substantially reduce the amount of oxygen scavenging chemicals required. Hot-well The importance of the boiler feed tank, where boiler feed water and make-up water are mixed and stored and into which condensate is returned, is often underestimated. Most items in the boiler house are duplicated, but it is rare to have two feed tanks. This crucial item is often the last to be considered in the design process. The feed tank is the major meeting place for cold make-up water and condensate return. It is best if Cost savings associated with reducing the dissolved oxygen in feed water by heating Basis for calculation: The standard dosing rate for sodium sulphite is 8 ppm per 1 ppm of dissolved oxygen. It is usual to add an additional 4 ppm to maintain a reserve in the boiler. Typical liquid catalysed sodium sulphite contains only 45% sodium sulphite. Obviously a cost is involved in heating the feed tank, but since the water temperature would be increased by the same amount inside the boiler, this is not 14 15

9 grundfos boiler house components additional energy, only the same energy used in a different place. The only real loss is the extra heat lost from the feed tank itself. Provided the feed tank is properly insulated, this extra heat loss will be insignificant. To avoid this problem, it is essential to provide the best possible Net Positive Suction Head (NPSH) to the pump so that the static pressure is as high as possible. This is greatly aided by locating the feed tank as high as possible above the boiler, and generously sizing the suction pipework to the feed pump (Fig. 14). An important additional saving is reducing the amount of sodium sulphite added to the boiler feed water. This will reduce the amount of bottom blowdown needed, and this saving will more than compensate for the small additional heat loss from the boiler feed tank. Fig. 14: NPSH above feed pump To avoid damage to the boiler itself The boiler undergoes thermal shock when cold water is introduced to the hot surfaces of the boiler wall and its tubes. Hotter feed water means a lower temperature difference and less risk of thermal shock. Boiler feed tank To maintain the designed output The lower the boiler feed water temperature, the more heat is required in the boiler to produce steam. It is important to maintain the feed tank temperature as high as possible, to maintain the required boiler output. Static height Cavitation of the boiler feed pump Caution: very high condensate return rates (typically over 80%) may result in excessive feed water temperature, and cavitation in the feed pump. If water close to boiling point enters a pump, it is liable to flash to steam at the low pressure area at the eye of the pump impeller. If this happens, bubbles of steam are formed as the pressure drops below the water vapour pressure. When the pressure rises again, these bubbles will collapse and water flows into the resulting cavity at a very high velocity. Boiler feed pump This is known as cavitation ; it is noisy and can seriously damage the pump

10 grundfos boiler house components Make-up water Cold water from the water treatment plant makes up any water losses in the system. Conductivity probes. Float control. Differential pressure cells. Many water treatment plants need a substantial flow in order to achieve optimum performance. A trickle flow as a result of a modulating control into the feed tank can, for example, have an adverse effect on the performance of a softener. For this reason a small plastic or galvanised steel cold make-up tank is often fitted. The flow from the softener is controlled on / off into the make-up tank. From there a modulating valve controls its flow into the feed tank. This type of installation leads to smoother operation of the boiler plant. To avoid the relatively cold makeup water sinking directly to the bottom of the tank (where it will be drawn directly into the boiler feed water line), and to ensure uniform temperature distribution, it is common practice to sparge the make-up water into the feed tank at a higher level. Water level transmitter In all steam boilers it is of utmost importance to have a constant water level in order to have a safe boiler operation and to maintain a good steam quality. The steam boiler is normally equipped with the following transmitters: Safety Low low level, burner shut down. Low level alarm. High level alarm. Control Low level, pump start. High level, pump stop. The level transmitters can be placed directly in the boiler shell or in external chambers. The water level detected will always deviate from the actual water level in the boiler. How much it deviates depends on boiler construction and sensor placement. The use of the different control systems is described in detail under section Boiler systems. Level control valve and actuators The level control valve actuator receives a level signal from the level transmitter and, in response, moves the valve to a position that corresponds to the signal. The actuator moves the valve stem and adjusts the flow depending on the valve characteristic. The valve characteristic depends on valve design and will not be described further in this literature. Control valve sizing In order to size a valve for a water application, the following must be known: Volumetric flow rate through the valve Differential pressure across the valve Talking valve capacities they are generally measured in terms of K v. More specifically, K vs relates to the pass area of the valve when fully open, whilst K vr relates to the pass area of the valve required by the application. The simplified equation for pressure drop when pumping water is expressed like this: The control level transmitter can also be a modulating type which can work according to the following principles: 18 19

11 grundfos boiler systems T he K v value for the valve can then be determined: Boiler systems Pumps A large range of pumps can be used for boiler applications depending on type of boiler and where used in the application. For a boiler application, with a flow of 26 m 3 /h including safety factors and the request for 2 bar pressure drop over the control valve, the K v value is 18.3 which in practice is a K v of 20. The values can also be found in a K v chart: Fig. 15 (Source: This section describes the typical positioning of the various pumps and how they are controlled. The most common boiler applications are boiler feed, condensate pumping, economizer circulation and shunt pumps. Sub-system pumps, such as dosing and water treatment pumps, are also used but will not be described in this literature. Hot water boiler Shunt pump The requirements of a shunt pump are normally high flow and very low head. The shunt pump is therefore normally made with a 4-pole or 6- pole motor to get the head down. Shunt pumps are normally singlestage pumps

12 grundfos boiler systems On/off shunt pump Fig. 16 Fig. 17 Shunt pump with variable speed Steam boiler Steam boiler feeding can normally take place in below 4 ways: On/off control Through feed valve (with and without bypass) Through feed valve and variable speed (with and without bypass) Variable speed The 4 methods mentioned above are the most common and will be described in the following. Please be aware that you can easily find a mix of the 4 systems. On/off control Function In on/off control the feed pump is switched on/off through a level sensor or a differential pressure sensor. When the water level falls to the Pump on level, the pump starts pumping a large quantity of relatively cold water into the boiler. This will reduce the quantity of steam and cause the steam pressure to fall. This is the reason why on/off control causes variations in steam production. It may also cause over-boiling in the boiler, which may cause water to enter the system. Benefits Function Function Fig. 18: On/off control Inexpensive The shunt pump must ensure that the return The shunt pump must ensure that the return Easy to install temperature to the boiler does not become too low. temperature to the boiler does not become too No bypass If the differential temperature between the return low. If the differential temperature between pipe and the forward pipe varies too much it will give a huge stress on the boiler structure. The pump must the return pipe and the forward pipe varies too much it will give a huge stress on the Deaerator Drawbacks Poor steam quality be sized according to the lowest return temperature, boiler structure. A variable speed pump may Big stress on boiler construction. meaning it is over-sized most of the time. be the correct choice for this type of pump application. The pump must be installed with Benefits a temperature sensor registering the return Inexpensive and easy to install temperature to the boiler, thereby ensuring a Safe operation (few components) constant temperature. Important! Benefits Information about correct return-pipe temperature to be obtained from boiler manufacturer. Always constant return temperature no matter the load on the system Control box Level sensor Same load on boiler to keep same differen- Energy savings tial temperature. Important! Burner Information about correct return temperature to be obtained from boiler manufacturer. Accessories required Temperature sensor, R100/Grundfos Go Feed pumps Steam boiler 22 23

13 grundfos boiler systems Through feed valve Through feed valve and variable speed Bypass Deaerator Fig. 19: Through the feed valve Fig. 20: Through feed valve and variable speed Control box Level sensor E P M Burner E Feed pumps Steamboiler Function Function In this type of system the water level in the boiler is controlled by a feed valve, which is controlled by a level sensor or a differential pressure transmitter positioned on the boiler. The feed valve controls the water intake, which is adjusted according to the steam consumption. This, however, requires that the feed pump is set to continuous operation. This system operates smoothly and is ideal for all types of steam boilers, both small and large, and will minimise the risk of over-boiling. Normally there are to ways to make the bypass, either with a valve or an orifice. If it is a valve it is normally controlled that it will start to open when the regulation valve is closed to a certain level. This to avoid the continuously energy loss you would have if it was open all the time. Benefits Boiler feed adjusted according to steam consumption, as described. Drawbacks The pump must be set to continuous operation (energy consumption) Bypass, creates an unnecessary energy loss. The feed valve is expensive Pressure loss across the feed valve Important! Remember to size bypass according to the CR pump s min. flow, which is 10% of the nominal flow for the pump. It may be an idea to stop the pump when the valve is closed. This requires, however, a signal from the valve. In this system the water level in the boiler is controlled by a feed valve, which is controlled by a level sensor or a differential pressure transmitter positioned on the boiler. The feed valve controls the water intake, which is adjusted according to the steam consumption. This, however, requires that the feed pump is set to continuous operation. This system operates smoothly and is ideal for all types of steam boilers, both small and large, and will minimise the risk of over-boiling. Normally there are two ways to make the bypass, either with a valve or an orifice. If it is a valve it is normally controlled so that will start to open when the regulation valve is closed to a certain level. This to avoid the continuously energy loss you would have if it was open all the time. Benefits Boiler feed adjusted according to steam consumption Energy savings on pump operation Constant differential pressure across the feed valve Drawbacks Bypass, with energy loss The feed valve is expensive Pressure loss across the feed valve Important! Requirements vary from one country to another as regards the sizing of boiler feed pumps. Remember to size bypass according to the CR/ CV data as well as to min. flow. It may be an idea to stop the pump when the valve is closed. This requires, however, a signal from the valve. Find out whether variable speed control of both pumps is required as this increases expenses, but does not provide the same flexibility as to alternating the pump operation

14 grundfos boiler systems Variable speed Boiler feed pump is usually in a duty/stand-by configuration, as shown on the sketch (Fig. 22). Deaerator Fig. 22 Fig. 21. Variable speed Condensate Steam outlet LT Sensor max. Hi_hi_alarm alarm f_min stop+hysteresis Control box Level sensor Stop Min. pump speed Max. E Burner Lo_alarm warning Sensor min. E Feed pumps Function In this system the water level in the boiler is controlled directly by the variable speed pumps without using a feed valve. The pumps are controlled by a level sensor or a differential pressure transmitter positioned on the boiler. This way the water intake is controlled according to the steam consumption. This system operates smoothly and is ideal for all types of steam boilers, both small and large, and will minimise the risk of over-boiling. Regulation loop The regulation loop has to be set up precisely so the level will be as accurate as needed and the pump will stop if no water is needed. Steam boiler Energy By control of the level in the boiler directly with the variable speed pumps you also have the most energyefficient way of making boiler feeding. There is no unnecessary flow in a bypass and the continuous pressure loss over the control valve is eliminated. Doing a simple calculation on how big the energy loss actually is, often is quite surprising. As an example: Standard steam boiler application, with a steam production of 20 m 3 /h, and a pressure loss over the valve at 5 bar. The load profile of the boiler is divided into 5 periods, the following calculations can be made: 100% load = 20 m 3 /h in 1752 hours a year 75 % load = 15 m 3 /h in 1752 hours a year 50 % load = 10 m 3 /h in 1752 hours a year 25 % load = 5 m 3 /h in 1752 hours a year And stopped in the rest 1752 hours a year Fig. 23 Level Sensor Max. Level Stop Min. Speed Max. Speed Min. Level Signals and Alarms Sensor max. Hi_hi_alarm alarm f_min stop+hysteresis Stop Min. pump speed Max. Lo_alarm warning Sensor min

15 grundfos condensate system Fig. 24 Fig ,,,,, Boiler pressure And remember the savings above are without the loss saved in the bypass end. Minimum flow for pump Minimum speed, set with R100/Grundfos Go Benefits As described, boiler feeding adjusted according to the steam consumption Energy savings on pump operation No pressure loss across the feed valve Money earned equal to the price of an expensive feed valve, and its maintenance costs. Drawback Requires precise and qualified start-up Important! A minimum frequency must be defined ensuring that the pump can always overcome the pressure in the boiler, and supply the minimum flow for the pump. May be carried out with the min. curve option for the pump. It must be ensured that the pump stops when steam consumption is zero. May for instance be carried out with a high level switch from the boiler. The regulator area may be small. If the 4-20mA level sensor is for example 2 metres and regulation takes place in an area of just 20 cm corresponding to app. 2 ma, then the regulation gab will be very narrow. The level signal is normally inverted. This means that if you get 20 ma from the level sensor, the boiler is full and then the pump should stop instead of speeding up. Condensate system Feed water The importance of correct feed-water treatment for economic operation and for extending life of boiler and equipment cannot be over emphasized. Feed-water treatment is essential in boilers, feedsystems, etc., more particularly in modern boilers of a high evaporative rate. (The faster a steam boiler or generator will convert water to steam, the more rapidly the solids in 28 29

16 grundfos condensate system the water will concentrate). So, large and small watertube boilers, the typical fire-tube packaged boiler, and steam generators are all examples of this in varying degrees. As all untreated waters carry natural salts, they have to be treated to prevent scale forming. The three main reasons for water treatment are: Prevention of corrosion in feed boiler, steam and condensate systems. Elimination of scale. Economic boiler operation without carry-over. Corrosion will reduce metal thickness of tubes or shell. Result: pressure must be reduced and finally boiler condemned. Scale reduces the heat flow from fire side to water. Result: higher gas temperature is needed to maintain the same heat transfer and the efficiency of the boiler will drop due to higher losses through the flue gasses. Carry-over is a collective term to describe the entrainment of a relatively small quantity of boiler water solids with the steam. Carryover occurs as a result of either foaming or priming, or by a combination of both. Foaming is the formation of bubbles on the surface of the boiler resulting in the throwing over of slugs of boiler water with the steam. This is similar to the bumping experienced when water is boiled in an open vessel. Fig. 26 Impurity Effect on a boiler Dissolved Gases The two gases which cause corrosion are oxygen and carbon dioxide. The carbon dioxide does so simply by dissolving in the water and forming a weak carbonic acid which attacks the metal in feed systems, boiler or condensate systems. Oxygen is present in all waters, so that red iron oxide forms on a mild steel surface immersed in water. This rusting or, as we call it, corrosion triunes until the metal is corroded away. If the amount of oxygen in the water is restricted, the oxide film does not form so readily; but instead, the surface of the steel tarnishes. This tarnish is usually the development of a thin film of iron oxide on the metal surface which is not so fully oxidized as the red iron oxide, and is more dense, thus tending to resist further corrosive attack. In water of increasing alkalinity, the oxide film becomes more stable and gives more protection to the steel, but until a definite alkalinity is reached, it still tends to break down in selective areas, where pits will develop. Calcium and magnesium salts There are two forms of hardness; temporary and permanent. Temporary hardness is due to bicarbonates of calcium and magnesium which breaking to carbonates when the water has boiled. In the boiler the following chemical reaction takes place : Calcium bicarbonate + heat. Calcium carbonate + carbon dioxide + water. Calcium and magnesium bicarbonate are soluble in water but carbonates are insoluble and therefore precipitate as a fine white powder. This precipitate will bake unto the heating surface of a boiler and form a scale. Dissolved gases Calcium and magnesium salts Silica Suspended and dissolved solids Corrosion These salts are the hardness in the boiler Some salts can also cause corrosion Can form a very hard scale Contribute to or cause carryover Permanent hardness is due to calcium and magnesium sulphates, chlorides and nitrates, and these salts cannot be removed by boiling. However, under boiler conditions (resulting in successive concentrations of these hardness salts) the solubility of these salts is soon exceeded and they deposit on the hottest part of the heating surface. The salts of magnesium 30 31

17 grundfos condensate system that form permanent hardness sometimes tend to cause corrosion instead of hard scale formation, e.g. magnesium chloride in an untreated boiler hydrolyses to form corrosive hydrochloric acid. Silica Silica forms scale in a similar way to the permanent hardness salts. When the scale formed is a mixture of silica, calcium and magnesium salts, it is very hard and therefore presents a difficult problem at inspection time. The suspended and dissolved solids The suspended and dissolved solids cause foaming by becoming absorbed unto the walls of individual bubbles so that small bubbles, instead of coalescing to form large ones and bursting early, repel one another and build up a large volume of small bubbles. If these bubbles burst near the steam outlet, the spray is taken over with the steam. If the bubbles do not burst high in the steam space, the foam can be drawn over with the steam. The composition of boiler feed water must be such that the impurities in it can be concentrated a reasonable number of times inside the boiler, without exceeding the tolerance limits of the particular boiler design. If the feed water does not meet these requirements it must be pre-treated to remove impurities. The impurities need not be completely removed in all cases, however, since chemical treatment inside the boiler can effectively and economically counteract them. Steam traps The duty of a steam trap is to discharge condensate while not permitting the escape of live steam. No steam system is complete without that crucial component the steam trap (or trap). This is the most important link in the condensate loop because it connects steam usage with condensate return. A steam trap quite literally purges condensate, (as well as air and other incondensable gases), out of the system, allowing steam to reach its destination in as dry a state/condition as possible to perform its task efficiently and economically. The quantity of condensate a steam trap has to deal with may vary considerably. It may have to discharge condensate at steam temperature (i.e. as soon as it forms in the steam space) or it may be required to discharge below steam temperature, giving up some of its sensible heat in the process. The pressures at which steam traps can operate may be anywhere from vacuum to well over a hundred bar. To suit these varied conditions there are many different types, each having their own advantages and disadvantages. Experience shows that steam traps work most efficiently when their characteristics are matched to that of the application. It is imperative that the correct trap is selected to carry out a given function under given conditions. At first sight it may not seem obvious what these conditions are. They may involve variations in operating pressure, heat load or condensate pressure. Steam traps may be subjected to extremes of temperature or even water hammer. They may need to be resistant to corrosion or dirt. Whatever the conditions, correct steam trap selection is important to system efficiency. It will become clear that one type of steam trap cannot possibly be the correct choice for all applications. How steam traps operate There are three basic types of steam trap into which all variations fall, all three are classified by International Standard ISO 6704:1982. Types of steam trap Thermostatic (operated by changes in fluid 32 33

18 grundfos pump sizing temperature) - The temperature of saturated steam is determined by its pressure. In the steam space, steam gives up its enthalpy of evaporation (heat), producing condensate at steam temperature. As a result of any further heat loss, the temperature of the condensate will fall. A thermostatic trap will pass condensate when this lower temperature is sensed. As steam reaches the trap, the temperature increases and the trap closes. Mechanical (operated by changes in fluid density) - This range of steam traps operates by sensing the difference in density between steam and condensate. These steam traps include ball float traps and inverted bucket traps. In the ball float trap, the ball rises in the presence of condensate, opening a valve which passes the denser condensate. With the inverted bucket trap, the inverted bucket floats when steam reaches the trap and rises to shut the valve. Both are essentially mechanical in their method of operation. Thermodynamic (operated by changes in fluid dynamics) - Thermodynamic steam traps rely partly on the formation of flash steam from condensate. This group includes thermodynamic, disc, impulse and labyrinth steam traps. Pump sizing In the EU, the EN norm has to be used when sizing pumps. However, please check the requirements in your local country. Flow safety factor according to EN The feed pump capacity shall correspond at least to 1.25 times the allowable steam output of all steam boilers. For safety reasons, 1.15 times of maximum continuous rating is enough. For availability and difference in service conditions a greater margin may be necessary. Where boiler waters are constantly blown down in volumes exceeding 5% of the allowable steam output, the feed pump capacity shall be increased by the corresponding percentage, e.g. if the blow down is 8% of the allowable steam output, the feed pump capacity shall be increased by 8%. (So in basic the pump size must be 25% larger than what is mentioned on the boiler nameplate, when it comes to flow. Remember to add the amount of water in the bypass. The amount can be controlled by an orifice or by control valve which might be open at the same time as the regulation valve) Also loosely included in this type are fixed orifice traps, which cannot be clearly defined as automatic devices as they are simply a fixed diameter hole set to pass a calculated amount of condensate under one set of conditions. All rely on the fact that hot condensate, released under dynamic pressure, will flash-off to give a mixture of steam and water. Pressure safety factor according to EN The feed pump shall be capable of supplying the steam boiler with both the feed water quantity at maximum allowable pressure as specified above and the feed water quantity corresponding to the allowable steam output 1.1 times the allowable working pressure. In some countries you are allowed to reduce the 10% if the security valve is of a certain size. Please check the local rules and regulations. (So in basic the pump size must be 10% larger than mentioned on the boiler nameplate, when it comes to pres

19 grundfos pump sizing sure. Remember to add the pressure loss in regulation valve and pipes between pump and boiler) Besides the rules and regulations above, you cannot just read the flow and pressure on the boiler nameplate and use this data to size the pump. This is because of the high temperature of the water and hereby the lower density of the pumped water. See the example below. Be aware that pumps in boiler applications are not part of the Pressure Equipment Directive 97/23/EC (PED) according to guideline 1/11. Example of flow and head calculation The following information is taken from the boiler nameplate, see fig. 28. Q Boiler = 20 tons/hour P Boiler max = 12.5 bar P Boiler operating = 10 bar Temp. = 175 C It is seen on the illustration above, that 175 C mentioned on the nameplate is the temperature of the steam in the outlet of the boiler. This information, however, is of no use, as the pump never registers what happens in the boiler. When sizing, always use the temperature in the deaerator. From the vapour table the following data of water at a temp. of 104 C is given. Density (rho)= kg/m 3 Vapour pressure = bar First the data from the nameplate have to be converted into m 3 /h and mwc, which can be used in the sizing. Fig. 27 Condensate Deaerator Apply safety factors from EN , flow and head becomes as specified below. 5 m Boiler Steam 20 tons/hour 175 C Q Pump max = 1.25 x Q Boiler = 1.25 x 20.9 = 26.1 m 3 /h Q = 1.15 x Q = 1.15 x 20.9 = 24.0 Pump continuous Boiler m3 /h h Pump = 1.1 x h Boiler = 1.1 x = m In the example the pressure drop in regulation valve Feed pump Burner and flow in bypass has not been taken into consideration. All values are now calculated and the pump can be chosen. Please note that the pump does not have to handle both flow and pressure with safety factors at the same time

20 grundfos pump sizing It should be carried out as shown below and in fig 29. Situation 1: Flow 26.1 m 3 /h with safety factor at m Fig. 28 H (m) % CRE Q = 26.1 m³/h H = 133 m n = 100% / 50 Hz Example: With the value from earlier and the tank placed 5 m above the pumps, the following formula is found: Situation 2: Head m with safety factor at 20.9 m 3 /h From these situations the following pump is chosen as it can handle both situations. Now the pump is selected but before ordering, the NPSH A value has to be calculated. NPSH A = Pressure AVAILABLE to the pump from the system. NPSH R = Pressure REQUIRED from the pump to avoid cavitation. To avoid pump cavitation, the following has to be accomplished, NPSH A > NPSH R NPSH A = h b h f h v ± h geo h s NPSH A = Pressure available at inlet of pump. = Atmospheric and deaerator operating h b h f h v h geo h s pressure at pump site. = Friction loss in suction pipe. = Vapour pressure of liquid. = Height between water level in deaerator and suction side of pump. = Safety factor. Normally estimated between 0.5 and 1 m Q = 20.9 m³/h H = 147 m 20 Eta pump = 68.9% Eta pump+motor = 58.9% Q(m³/h) P P2 = 13.6 kw NPSH (kw) P1 = 16 kw (m) 16 P1 8 P NPSH = 3.83 m As mentioned earlier the density of 104 C water must be used as this is what the pump meets. However, taking another look at the formula it is obvious that the h b and the h v equalize each other. The reason is that the water in the deaerator is normally kept at the boiling point. This phenomenon will always occur in a boiler system and because of that, the formula can be simplified: NPSH A = h f ± h geo h s Instead of using boiling to drive the oxygen out of the water, it is possible to add chemicals instead. In that type of application the water is heated to approx. 80 C instead. The application gives an NPSH A at 2 m, and the selected pump has a NPSH-value way above that. Due to this it is necessary to look at the low NPSH versions of the pumps, see fig. 29. Fig. 29 H [m] 20 QH 2900 rpm 1 NPSH [m] 8 15 QH 2900 rpm 1n NPSH LOW NPSH Q[m³/h]

21 grundfos grundfos solutions As the curve shows, this pump can be used in a low NPSH version. A pump to do the job has been found, fig. 31. Put in the actual duty point and it looks alright, but if it is compared to the pump with 2 impellers less, the latter looks even better, fig. 32. However, please be aware if the pump with 12 impellers is chosen, it must run over-synchronous to reach the duty point according to the EN norm. The choice depends on the application and requests. Grundfos solutions E-Solutions E-solutions are the Grundfos term for motors equipped with internal, MGE, or external, CUE, variable frequency drive. General benefits 1. Energy saving Reduced Life Cycle Cost and reduced CO 2 emission H (m) Fig % 85% CRE Q = 20.9 m³/h H = 107 m n = 85% / 42 Hz Fig Increased comfort Reduced noise from installation, Constant pressure No water hammering 3. Make processes work Adapts automatically to changes in system Control and regulation of critical parameters Reduced total system cost Speed controlled pumps can make some valves etc. unnecessary Reduced installation and commissioning costs Eta pump = 71.3% Eta pump+motor = 60.9% Q(m³/h) P P2 = 8.55 kw NPSH (kw) P1 = 10 kw (m) 16 P1 8 P NPSH = 2.13 m Protection of pump, motor and electronics Reduced stress on motor, pump and system Overload protection of motor and electronics Pump curve compensation In boiler feed the pumps are often operating at low flow and still at full boiler pressure. When these conditions are present centrifugal pumps have some limitations in their natural performance as the pump curve gets unstable in the low flow area. This gets even more explicit when the load curve is flat, like in boiler feed, and that is a regulating challenge. See fig. 32 and

22 grundfos grundfos solutions Fig. 32 H (m) 100 Setpoint CRN As a special function in the Grundfos frequency converter. it is possible to compensate for this phenomenon by altering the internal motor control. Fig Inverse Normal regulation Flow range The maximum RPM of the motor is increased to 55 Hz, or 58 Hz if required, and at the same time the slippage of the motor is increased. When the pump is running at low load, due to low flow, the speed of the pump is high. When the flow increases the load increases and because of the larger slippage the pump speed will decrease and fold back to the original pump curve at 50 Hz, even though the motor is still running 55 Hz. See fig Q(m³/h) P2 NPSH (kw) (m) Fig. 33 H (m) rpm rpm Q Q Inverse regulation Q rpm Normal regulation Q(M 3 /h) Q rpm Set point The pump curve is now continuously decreasing and the instable part of the pump curve is eliminated. More important: The regulating loop can work as expected. See fig. 35. Air-cooled top As mentioned in passage Economizer, the boiler feed pumps are sometimes installed so that they meet the boiler pressure and temperature. These temperatures are sometimes higher than what the shaft seals can handle. The solution can be an air-cooled top. A CR pump equipped with air-cooled top can handle temperatures of 180 C in water and 240 C in thermal oil. The air-cooled top separates the seal chamber from the pump by an air-cooled chamber, generating an insulating effect similar to that of thermos. The cooling air from the motor keeps the chamber cooled down. Via a small gap at the shaft from the pump to the air-cooled top, a small quantity of the pumped liquid ensures that the seal chamber is always filled with liquid. Fig

23 grundfos grundfos solutions The air-cooled top solution is a stand alone pump Fig. 36 Air cooled top Bearing flange Fig. 38: Bearing flange meaning no external liquid is needed to cool down The bearing flange is an additional flange with an the shaft seal. oversize ball bearing to absorb axial forces in both directions. Low NPSH The bearing flange ensures long life time when run- The CR Low NPSH is actually a standard pump provi- ning conditions are rough. ded with an oversize impeller in the first stage. The oversize impeller has a larger eye than the standard The typical use of bearing flanges: impeller and therefore better capable of handling When the pump is equipped with standard motor poor inlet pressure and hot water. the bearing flange can compensate for the hydraulic forces from pump, ensuring an acceptable lifetime The Low NPSH can handle the same operating pres- on motor bearings which are not dedicated for pump sure and temperature as the standard CR pumps. applications. When the pump is run with higher inlet pressure MAGdrive Double shaft seal or Magdrive than the maximum pressure recommended. For feed pumps pumping from a vacuum tank, there MP 204 Fig. 39: MP 204 is a risk of air infiltration to the pump through the If the pumps in the boiler system are without shaft seal. This phenomenon occurs when two feed frequency converters it is important to protect them pumps are operate parallel as duty standby pumps. Fig. 37 Double seal in another way. For that, Grundfos has developed the Here, there is a risk that the standby pump may let air MP 204, which is an intelligent motor protection, that through the shaft seal due to vacuum in the deaera- not only protects the motor but also tells something tor / condensate tank. This problem can be addressed about the performance of the pump/motor. by installing pumps with a double shaft seal arrangement with barrier water or a Mag-Drive pump. Read The features that it can measure are among others: more about our custom-built pumps in the Grundfos Load issue. catalogue. Power supply. Temperature. Double seal Ground fault. Can be applied in hot water installations, i.e. economizer applications, where the quench liquid is used for cooling shaft seal surfaces. CUE If the E-solution mentioned earlier, is not appropriate, Fig. 40: CUE with the frequency converter installed directly on Can also be applied in vacuum installations where the motor, or the motor power is too high for an on it is necessary to ensure, that air does not enter the board solution, Grundfos also has a wall-mounted condensate. frequency converter, the CUE. Key benefits by CUE compared to standard VLT: Very easy start-up wizard GRUNDFOS graphical display 44 45

24 grundfos grundfos solutions Well-known GRUNDFOS E-pump functionality as standard Pre-programmed for GRUNDFOS pumps RFI filter (C1) for domestic areas included for: 1 x V all sizes 3 x V all sizes 3 x V up to / including 90kW RFI filter (C2 or C3) for industrial areas included for all remaining sizes and voltages Bearing supervision as standard (for standard motors with re-lubrication facilities) Standstill heating possibilities (for motors in condensing areas) GRUNDFOS GENIbus as standard CIM/CIU: CIM/CIU products are products developed by Grundfos so electronic solutions mentioned earlier, such as the MGE motor, MP204 and CUE can communicate with the rest of the control world. The CIM/CIU gateways can translate the Grundfos fieldbus to all other standard fieldbus types used in the market for example Profibus, Modbus and Lon. The CIM/CIU products are built in two versions; one for wall-mounting and one as add-on card. Add-ons are for a limited series of products. Monitor The Grundfos CR Monitor is a product that takes early warning to a new level. Normally, when we talk monitoring systems there is nothing between All okay and ALARM! but the CR Monitor deals with that and introduces Warning. This warning gives you time to act to prevent unnecessary power loss and breakdown and most importantly to prevent production loss due to lack of steam production. This new, automated supervision tool can foresee efficiency drop, pump failure and prevent cavitation in inline centrifugal pump installations. And especially caviation problems which in the end will lead to efficiency drop and a broken pumps are faults we see most often in boiler feed installations. Fig. 41: CIM/CIU Fig. 42: Monitor The main tasks of CR Monitor is, as mentioned earlier, surveillance, surveillance, surveillance and simple communication. Despite the complexity that makes the unit possible, the system only communicates on three levels: All okay, Warning and ALARM. The latter two are accompanied by plain language interpretations of the data that trigger the warning. Cavitation prevention Without all standard measurings and the intelligent efficiency measuring it also measures how close the installation is to cavitation. Normally the first sign of cavitation which meets the pump is the disconcerting sound of gravel from the pump. And especially in boiler feed applications where there is always a risk of cavitation (sometimes impossible to avoid), the CR Monitor can constantly report on the available NPSH at any given moment. And not only that: if you have had cavitation because a fault or another unnormal operation pattern of the boiler has happened the CR Monitor can immediately tell by the efficiency monitoring if the cavitation has harmed the pump. So said in another way CR Monitor can give peace of mind. Power-saving By monitoring the pump efficiency, it is possible to assess the state of the pump hydraulics. So not only if you have faults in the system but also if you just have simple wear of the pump hydraulic, the CR Monitor will warn you before the pump completely stops. And efficiency monitoring becomes a decisionmaking tool. So once a certain efficiency drop has been reached, the decision can be made to service the pump, restoring its original capacity. It can also be a question of getting the most for your maintenance time and money. There s no point in servicing a pump every 12 months if it does not need it. So, fundamentally it monitors that the efficiency is at its best around the clock regardless of duty point

25 grundfos grundfos solutions Some of the unique advantages and selling points are mentioned below. Surveillance of motor and pump: Efficiency (no unnecessary power loss) Under/overvoltage Overheating Too high power consumption Bearing surveillance Protection against dry-running Cavitation prevention supply. The probe is fitted with a protection tube inside the feed tank to protect it from turbulence, which can result in false readings. Water level indicator A local level indicator or water level gauge glass on the feed tank is recommended, allowing the viewing of the contents for confirmation purposes, and for commissioning level probes. System and liquid surveillance: Process out of range Liquid temperature Pressure Flow Aux analogue input Reduce maintenance and stock: Periodic maintenance is history No unnecessary maintenance. Reduction of spare parts on stock Reduction of man hours to service Regular manual pump inspection is history Unexpected downtime is reduced to an absolute minimum. CR Monitor provides supervision 24/7/365 Level control condensate Traditionally, float controls have been used for this application. Modern controls use level probes, which will give an output signal to modulate a control valve. Not only does this type of system require less maintenance but, with the use of an appropriate controller, a single probe may incorporate level alarms and remote indicating devices. Level probes can be arranged to signal high water level, the normal working (or control) water level, and low water level. The signals from the probe can be linked to a control valve on the cold water make-up 48 49

26 grundfos theory/problems Theory/problems Cavitation Since the water in the deaerator or the condensate tank has a high temperature, it is difficult to pump without causing the pump to cavitate. The higher the temperature, the more likely cavitation will occur. This is because the pump has to pull the water in the first impeller and as a result, the pressure will drop a little and the water will start to evaporate. When the pressure is rising through the impeller and the small steam bobbles begin to implode and return to liquid form, it is called cavitation. Because of this problem, the deaerator / condensate tank is often placed several metres above the pump inlet to ensure as high an inlet pressure as possible. The pump can be made with a special first stage design to reduce the pump s NPSH value. See more under sizing of pumps. Fig. 43 Water hammer Water hammer (or, more generally, fluid hammer) is a pressure surge or wave resulting when a fluid (usually a liquid but sometimes also a gas) in motion is forced to stop or change direction suddenly (momentum change). Water hammer commonly occurs when a valve is closed suddenly at the end of a pipeline system, and a pressure wave propagates in the pipe. It may also be known as hydraulic shock. This pressure wave can cause major problems, from noise and vibration to pipe collapse. It is possible to reduce the effects of the water hammer pulses with accumulators and other features. Water hammer in boiler feed applications normally happens when interchanging between the duty/ standby pumps. The water in the standby pump is often cold and when the column of cold water hits the warm part, water hammer can occur. It can also occur between the pump and the boiler if valves are being closed fast, for example when changing from bypass to filling the boiler. Column separation Column separation is a phenomenon that can occur in a boiler feed application between deaerator and the pumps. It happens if the pressure in the pipeline drops rapidly to the vapour pressure of the liquid, the liquid will vaporise and a bubble of vapour will form in the pipeline. This is most likely to occur if knees or valves (changes in pipe slope) are installed in the piping. When pressure later increases above vapour pressure of the liquid, the vapour in the bubble returns to a liquid state leaving a vacuum in the space formerly occupied by the vapour. The liquid on either side of the vacuum is then accelerated into this space by the pressure difference. The collision of the two columns of liquid, (or of one liquid column if at a closed end,) results in water hammer and causes a large and nearly instantaneous rise in pressure. This phenomenon happens very fast and pressure peaks above 120 bar have been found. This pressure peak can destroy all sensors in the inlet of the pump and at the same time lift the chamber stack in the pump so explosively that the motor bearings can be damaged. Blowdown / skimming A problem often seen in boiler applications is cavitation due to bottom blowdown of the boiler

27 grundfos theory/problems A bottom blowdown is when water is let out from the water reservoir in the bottom of the boiler. The reason for doing this blowdown is that suspended solids in the water can be kept in suspension as long as the boiler water is agitated, but as soon as the agitation stops, the suspended solids will fall to the bottom of the boiler. If the solids are not removed, they will accumulate and, given time, will inhibit the heat transfer from the boiler fire tubes, which will overheat or even fail. The normal method of removing this sludge is through short, sharp blasts using a relatively large valve at the bottom of the boiler. The objective is to allow the sludge time to redistribute itself so that more may be removed at the next blowdown. The duration and frequency of the blowdown vary from the different boiler manufacturers. The pump problem starts when the blowdown time is so long, that the pressure in the boiler starts to fall. This will, or can, result in the feed pump running out of curve, meaning that the required NPSH value for the pump increases dramatically. And this results in cavitation and over time breakdown of the pump. Safety valve The safety valve is a very important fitting. Its function is to protect the boiler shell from over-pressure and subsequent explosion. Always ensure that local standards are complied with. The following standards are examples: BS 6759 in the UK, for materials, design and construction of safety valves. BS 2790 in the UK, for the design and manufacture of shell boilers of welded construction. EN ISO 4126 Continental Europe, General requirements for safety valves. Please see manufacturers material for detailed dimensioning and installation instructions. Weekend shut-down A lot of steam boiler applications have weekend shut-down. This means that the steam production is stopped during the weekend and the boiler is kept at a lower temperature but still ready for start-up again. How they choose to carry out this standby period varies from customer to customer, but often a little amount of steam is recycled from the boiler to the deaerator to keep that heated as well. From time to time the boiler is started to correct the levels in the boiler and deaerator and this may cause problems both with cavitation and water hammer: Cavitation due to a lower pressure in the boiler than normal and water hammer due to the column of water in the pump being cooled down at standstill as it is not insulated. And when the pump is subsequently started you send a column of cold water through the pipes resulting in water hammer in the system. Steam consumption changes Often the steam consumption changes over time and sometimes the production of steam is larger than stated on the boiler nameplate and hence the data available for Grundfos during sizing of the boiler feed pumps. This may result in too small pumps; meaning that the pumps run with too large flow and because of this, a higher NPSH is required. An example is a customer that once a month used steam for an hour to clean the turbines at the site. This resulted in very large pressure drops in the boiler and the result was that the pump cavitated that hour every month. Dosing Normally no problems arise due to the way the chemicals used are being dosed into the water. But from time to time an increase in tear of the impeller is seen. That happens when the chemicals are dosed directly in front of the feed pumps. This is because the concentration can be very high in the pump due to the chemicals having not been mixed properly before entering the pump

28 grundfos FAQ If it is a large CR with bronze bearing it is important to keep the PH-value in the boiler water below 10 as it will otherwise tear down the bronze. It is usually not a problem as the boiler manufacturer also has an interest in keeping the PH-value at approx Be aware that if NH3 is added to lower the PH-value, the NH3 will also tear down the bronze. Using the Grundfos Digital Dosing will eliminate the tear problems as the dosing pump will dose continuously and ensure that no excessive chemical levels occur. Feed pump start-up Before the pumps are started, the following two things have to be taken into consideration. If the pump is equipped with a frequency converter, it is important that the pump starts at such high speed that it delivers a higher pressure than the pressure in the boiler. If not, it will be like running against closed valves until the pump overcomes that pressure. This can result in a burned shaft seal. If the ramp up time is set to 0 sec., the water column in the inlet of the pump has been seen torn apart and some sort of vacuum pockets have been created. Se paragraph Column separation. FAQ How do I avoid cavitation? You must ensure that the pressure level at the suction side of the pump is higher than the vapour pressure of the water. Net Positive Suction Head (NPSH) available must be higher than NPSH required. See section Pump sizing. How do I convert from bar to mwc? In order to convert you need to know the temperature of the water as density varies with temperature. From the vapour table, the following data of water at a temperature of 104 C is given. Density (rho)= kg/m 3 The nameplate indicates a maximum boiler pressure of 12.5 bar and the value has to be in Pascal. The force of gravity g is 9.81 m/s 2. What precautions do I need to take when living at high altitude? If the deaerator is operated at the boiling point, no special precautions are necessary. The lower the pressure, the less oxygen can be dissolved in the feed water, which actually enhances deaeration. The precautions to avoid cavitation are the same as in section Pump sizing. See table below for boiling temperatures. Fig 44: Table based on the standard sea-level atmospheric pressure of kpa: Boiling point Altitude, m of water, C 0 (0ft) 100 (212 F) 300 (984.25ft) 99.1 (210.3 F) 600 (1968.5ft) 98.1 (208.5 F) 1000 (3280.8ft) 96.8 (206.2 F) 2000 ( ft) 93.3 (199.9 F) 4000 ( ft) 87.3 (189.1 F) 6000 ( ft) 81.3 (178.3 F) 8000 ( ft) 75.5 (167.9 F) 54 55

29 grundfos certificates Certificates Certificates Certificate Certificate of compliance with the order Test certificate. Non-specific inspection and testing Inspection certificate 3.1 Inspection certificate Standard test report Material specification report Material specification report with certificate from raw material supplier Duty-point verification report Surface-roughness Vibration report Motor test report Cleaned and dried pump Electropolished pump ATEX-approved pump Description According to EN 10204, 2.1. Grundfos document certifying that the pump supplied is in compliance with the order specifications. According to EN 10204, 2.2. Certificate with inspection and test results of a non-specific pump. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Certificate from the surveyor is included. We offer the following inspection certificates: Lloyds Register of Shipping (LRS) Det Norske Veritas (DNV) Germanischer Lloyd (GL) Bureau Veritas (BV) American Bureau of Shipping (ABS) Registro Italiano Navale Agenture (RINA) China Classification Society (CCS) Russian maritime register of Shipping (RS) Biro Klassifikasio Indonesia (BKI) United States Coast Guard (USCG) Nippon Kaiji Koykai (NKK) Certifies that the main components of the specific pump are manufactured by Grundfos, and that the pump has been QH-tested, inspected and conforms to the full requirements of the appropriate catalogues, drawings and specifications. Certifies the material used for the main components of the specific pump. Certifies the material used for the main components of the specific pump. A material certificate, EN 10204, 3.1, will be supplied for each main component. Certifies a test point specified by the customer. Issued according to ISO 9906 concerning "Duty point verification". Shows the measured roughness of the cast pump base of the specific pump. The report indicates the values measured at the base inlet and outlet according to ISO Vibration report indicating the values measured during the performance test of the specific pump according to ISO Shows the performance test of the specific motor, including power output, current, temperature, stator windings resistance and insulation test. Confirms that the specific pump has been cleaned and dried, and how it was done. Confirms that the specific pump has been electropolished. The maximum surface roughness is specified in the report. Confirms that the specific pump is ATEX-approved according to the EU directive 94/9/EC, the "ATEX directive"

30 58 grundfos boiler feed manual

GRUNDFOS IndustrY ENGINEERING MANUAL. Industrial Boilers

GRUNDFOS IndustrY ENGINEERING MANUAL. Industrial Boilers GRUNDFOS IndustrY ENGINEERING MANUAL Industrial Boilers 1 ENGINEERING MANUAL Copyright 2009 GRUNDFOS Management A/S. All rights reserved. Copyright law and international treaties protect this material.

More information

Boiler Feed Manual. L-BF-SL (US)

Boiler Feed Manual.  L-BF-SL (US) grundfos grundfos category INDUSTRY heading Boiler Feed Manual L-BF-SL-002 12-14 (US) GRUNDFOS Kansas City 17100 West 118th Terrace Olathe, Kansas 66061 Phone: (913) 227-3400 Fax: (913) 227-3500 www.grundfos.us

More information

Efficient Steam System Design

Efficient Steam System Design Efficient Steam System Design The word Efficient is often used to describe the general performance of a system. However it is important to distinguish between efficiency and effectiveness. Efficiency is

More information

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Introduction Wash & Clean systems for the food processing industry is an utility application that sets high requirements

More information

SECTION Boiler Controls & Waste Heat Recovery

SECTION Boiler Controls & Waste Heat Recovery 6 Boiler Controls & Waste Heat Recovery ARMSTRONG PRODUCT CATALOGUE 255 IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 147 Revised 7/09 TYPE.005 DA-STP Spray Tray Deaerating Pressurized Boiler

More information

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17 SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 107 Revised 5/17 Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed

More information

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09 SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 149 Revised 8/09 TYPE.005 DA-2C Deaerating Boiler Feed Pumps SHIPCO Deaerators

More information

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components: Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their

More information

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system EN Demineralised heating water perfect for every system PUROTAP easy Installation Function Operation Service fast efficient safe Minerals and salts in technical water circulations lead to corrosion and

More information

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task. Many processes today require an indirect method of heating, which implies the use of a heat transfer medium, instead of circulating the process directly into a heater. Thermal oil, water, glycol mixtures,

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016 Boiler Condensate Return Basics Presented by Steve Connor February 24, 2016 What We Are Covering Today? Brief review of the total steam system Why a proper condensate return system is so important Condensate

More information

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS Lesson 433.60-1 Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS It was noted in an earlier lesson, that the reactor is a source of heat, and serves the purpose of a "furnace"

More information

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information

Custom Design TYPE CS

Custom Design TYPE CS SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 109 Revised 3/05 Custom Design TYPE CS Cylindrical Steel Boiler Feed Pumps

More information

Chapter 2.3: Steam System

Chapter 2.3: Steam System Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high

More information

Adca Training. Part 2

Adca Training. Part 2 Adca Training Part 2 This presentation is only a guideline, that can only be completed by a trained personnel. (This document s total or partial use and/or reproduction is only allowed if the reference

More information

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Cast Line Heaters The Benefits of This Space Saving Electric Heater WHITE PAPER Cast Line Heaters The Benefits of This Space Saving Electric Heater Introduction Cast line heaters, or cast-in heaters, offer an alternative to the more common inline process heaters that have

More information

CHAPTER 3 BASIC STEAM CYCLE

CHAPTER 3 BASIC STEAM CYCLE CHAPTER 3 BASIC STEAM CYCLE To understand steam generation, you must know what happens to the steam after it leaves the boiler. A good way to learn the steam plant on your ship is to trace the path of

More information

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark Introduction: Energy use is the single largest operating expense in commercial office

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

Steam Trap Selection

Steam Trap Selection Steam Trap Selection Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less energy consumed means less

More information

IMMERSIBLE PUMPS FOR INDUSTRY

IMMERSIBLE PUMPS FOR INDUSTRY GRUNDFOS INDUSTRIAL SOLUTIONS Grundfos MTR, MTH, MTA, MTS pumps IMMERSIBLE PUMPS FOR INDUSTRY COMPACT TANK TOP SOLUTIONS FOR DEMANDING APPLICATIONS RENOWNED FOR THEIR RELIABILITY AND PRECISION MTA MTH

More information

Prepared by Technical Team

Prepared by Technical Team Prepared by Technical Team Summary Vacuum degassing (VD) and vacuum oxygen de-carburisation (VOD) are the main processes in secondary steel making. The large volumes of dissolved contaminant gases arising

More information

MAGNA3 More than A pump

MAGNA3 More than A pump MAGNA3 More than A pump Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications Features More than a pump If you

More information

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas: MAGNA3 We offer a complete range of MAGNA3 pumps with unrivalled efficiency, intelligent technology to match your every need and the well-known Grundfos reliability based on years of experience. MAGNA3

More information

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax: 9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: awt@awt.org Part of the recertification process is to obtain Continuing Education Units (CEUs). One way

More information

MFP14 Automatic pumps for condensate and other industrial fluids

MFP14 Automatic pumps for condensate and other industrial fluids MFP14 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

Multifunction pump for handling gaseous liquids in process engineering

Multifunction pump for handling gaseous liquids in process engineering Multifunction pump for handling gaseous liquids in process engineering Pumping liquids with a high gas content can be problematic, causing sharp losses in head and flow or even total cessation of pump

More information

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: BEST PRACTICE NO. 51 THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: the solution to increasing a steam system s thermal cycle efficiency Pressurized condensate systems can provide plants with a minimum of

More information

Steam Trap Inspection Methods And Steam Cost Analysis

Steam Trap Inspection Methods And Steam Cost Analysis Steam Trap Inspection Methods And Steam Cost Analysis 14 Hayes Street, Elmsford NY 10523-2536 USA Tel: 914-592-1220 Toll Free USA & Canada 24 Hour Fax Email: Internet 800-223-1325 914-347-2181 info@uesystems.com

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

How to Trap: Trap Selection and Safety Factors

How to Trap: Trap Selection and Safety Factors How to Trap: Trap Selection and Safety Factors Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less

More information

.03 ATMOSPHERIC DEAERATOR

.03 ATMOSPHERIC DEAERATOR .03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more

More information

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM BEST PRACTICE NO. 30 WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM Air and noncondensable gases are one of the major problems in a steam system that can cause production

More information

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR CONDITIONING. Carrier Corporation 2002 Cat. No AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)

More information

9. Cooling Water System

9. Cooling Water System 9.1 Water quality The fresh water in the cooling water system of the engine must fulfil the following requirements: ph... Hardness... Chlorides... Sulphates... min. 6.5...8.5 max. 10 dh max. 80 mg/l max.

More information

How to Trap: Troubleshooting

How to Trap: Troubleshooting How to Trap: Troubleshooting Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less energy consumed means

More information

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY A steam trap, which is a fully automated condensate drainage device, generally does not require routine maintenance. Steam

More information

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

Volume 10 Summer Understanding Terminology Key to Treatment Program Success Volume 10 Summer 2003 Understanding Terminology Key to Treatment Program Success One of the keys to success of a boiler water treatment program is good communication between the water treatment professional

More information

How to Trap: Process Air Heaters

How to Trap: Process Air Heaters How to Trap: Process Air Heaters 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing Energy Down to Earth

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +

More information

Monitoring Flammable Vapors and Gases in Industrial Processes

Monitoring Flammable Vapors and Gases in Industrial Processes Monitoring Flammable Vapors and Gases in Industrial Processes Flammability Hazards Industrial fires and explosions happen more frequently than most people think. They cause downtime, property damage, injury

More information

Exciting Swiss temperature control technology, distributed in North America exclusively by...

Exciting Swiss temperature control technology, distributed in North America exclusively by... Exciting Swiss temperature control technology, distributed in North America exclusively by... TM North America Frigel North America, Inc. 150 Prairie Lake Rd, Unit A East Dundee, IL. 60118 USA Tel (847)

More information

MFP14 Automatic pumps. for condensate and other industrial fluids

MFP14 Automatic pumps. for condensate and other industrial fluids MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager INTRODUCTION The science of creating vacuum is often misunderstood and when the desired vacuum condition is not being achieved in a manufacturing setting this usually means production comes to a halt and

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

This chapter is devided into two sections:

This chapter is devided into two sections: This chapter is devided into two sections: Page Installation requirements........................................................................ 127 The installation process..........................................................................

More information

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units Steam Site Guide Steam Site Guide Heat Exchange Applications - SI Units Steam Site Guide Content Introduction... 03 01. Estimating Steam Loads... 04 02. Steam Table SI... 07 03. Sizing a Steam Pipe...

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

spiraxsarco.com/uk Condensate recovery in industrial steam systems

spiraxsarco.com/uk Condensate recovery in industrial steam systems Condensate recovery in industrial steam systems c o n d e n s a t e r e c o v e r y Contents 1.0 Executive Summary 2.0 Rising pressures of using natural resources 3.0 The importance of effective condensate

More information

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

APPLICATION GUIDELINES STEAM MAIN DRAINAGE APPLICATION GUIDELINES STEAM MAIN DRAINAGE 1) Steam Main Drip Leg Dimensions 2) Types of Warm-Up a) Supervised b) Automatic 3) Spacing of Drip Legs 4) Low Pressure Drainage-- Sizing Traps for Automatic

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction A White Paper for the Enercon Venturi Condensate Removal (EVCR)

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

KRAL Screw Pumps. L Series.

KRAL Screw Pumps. L Series. KRAL Screw Pumps. L Series. Our new Medium Pressure Pump The new L pump makes life easier sturdy, with a low wear rate and easy to maintain. How the L pump fits into the KRAL product Applications. range.

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems

More information

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils Installation, Operation and Maintenance Guide Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils

More information

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager NHS Sustainable Development: 14 th February 2012 Reduce Energy Consumption Through Steam System Modernisation Presentation by: Andy Bennett National Key Account Manager 1 Overview 1. Thermal Energy International

More information

GESTRA Information A 1.7

GESTRA Information A 1.7 Issue Date: 9/06 GESTRA Systems GESTRA Information A 1.7 Automatic Deaeration of -Heated Heat Exchangers Preface For optimum efficiency of steam-heated heat exchangers several requirements should be fulfilled,

More information

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing 173.13.02 Utmost Efficiency VD / VOD processes Vacuum Degassing (VD) for low alloy steels; Vacuum Oxygen Decarburising (VOD) for stainless

More information

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion s Circulate Steam Boost Low- Steam Compress and Mix Gases in Desired Proportion S&K s are used in the process, paper, petroleum, power, gas, and other industries to circulate steam, boost low-pressure

More information

Boiler. Fire tube Boiler:

Boiler. Fire tube Boiler: Boiler What is Boiler? A closed metallic vessel in which the water is heated beyond the boiling temperature by the application of heat by the combustion of fuels to convert it into steam. The function

More information

MECHANICAL SCIENCE Module 2 Heat Exchangers

MECHANICAL SCIENCE Module 2 Heat Exchangers Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii

More information

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division INTRODUCTION PRESSURE-ENTHALPY CHARTS AND THEIR USE The refrigerant in a refrigeration system, regardless of type, is present in two different states. It is present as liquid and as vapor (or gas). During

More information

LUCKILY THERE S A BETTER WAY

LUCKILY THERE S A BETTER WAY CRAC EQUIPMENT Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability Ever-changing Challenges Cooling data centers and other mission-critical environments is a complex

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html

More information

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION cussons TECHNOLOGY THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION Thermodynamics is a branch of physical science concerned with the inter-relationship and inter-conversion

More information

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY 1 Boiler Room Hazards A Risk Of Explosion Exists High Pressure steam Combustion Gases Chemicals Moving Machinery Hot Surfaces www.bangladeshworkersafety.org

More information

How to Trap: Rotating Dryers Requiring Syphon Drainage

How to Trap: Rotating Dryers Requiring Syphon Drainage How to Trap: Rotating Dryers Requiring Syphon Drainage 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL HYDROFILL Hydronic water treatment filling units Copyright 2016 Caleffi OPERATING AND MAINTENANCE MANUAL NA10439 www.caleffi.com NA5709 series Function HYDROFILL is a water treatment fi lling unit that

More information

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability May 20, 2015 gforce Ultra White Paper gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability Seth Inyang, New Product Development Manager,

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases Thomas Ramme Dipl.-ing B.Eng.(Hons.), Nick Hayes MCMI Dip IM With the introduction of the ATEX guidelines

More information

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY THE ROTH SOLUTION PROVIDES: Lowest NPSHr - Lower Motor Speeds Lower Tank Heights - Reduced Maintenance ROTH PUMP

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers BUDERUS BUDERUS G1 1 1 G1 G1 G1Boilers Cast Iron Commercial High Efficiency Combustion Efficiencies Up to 88.2% 0 to,982 MBH Output Thermostream Design Eliminates Thermal Shock Superior Equipment by Design

More information

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery

More information

Technical Illustration of Condensate Formation

Technical Illustration of Condensate Formation Condensate Recovery As hot steam cools down inside a mill s pipes, the droplets of vapor turn into condensate water. If recycled, this condensate water can provide mills with an inexpensive source of clean

More information

VAC-U-DRY VACUUM DEHYDRATOR

VAC-U-DRY VACUUM DEHYDRATOR VAC-U-DRY VACUUM DEHYDRATOR Remove Free & Dissolved Water down to 20 PPM (0.002%) Flow range 5~60 gpm,19~225 lpm Visually Monitor Fluid and Process through Clear Chamber Covers High Operating Vacuum and

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

TECHNICAL MANUAL ASGX

TECHNICAL MANUAL ASGX TECHNICAL MANUAL ASGX MEDIUM/HIGH PRESSURE HOT WATER BOILER INDEX 1 TECHNICAL CHARACTERISTICS... 2 1.1 GENERAL... 2 1.2 TECHNICAL DATA... 2 2 ACCESSORIES... 3 2.1 PRESSURE... 3 Pressure gauge... 3 Operation

More information

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1 Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1 1. Define mechanical efficiency in case of an IC engine? [2015w] Ans. Mechanical efficiency of an I.C. engine is defined

More information

DEAERATORS .005 ATMOSPHERIC DEAERATOR

DEAERATORS .005 ATMOSPHERIC DEAERATOR 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 3300 DEAERATORS.005 ATMOSPHERIC DEAERATOR GENERAL DESCRIPTION The Sellers atmospheric.005

More information

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR General DICKOW-pumps of series HZ/HZA are single- or multistage centrifugal pumps with shaft sealing. Application HZ/HZA-pumps are applied

More information

.005 ATMOSPHERIC DEAERATOR

.005 ATMOSPHERIC DEAERATOR .005 ATMOSPHERIC DEAERATOR OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.005 deaerators condition make-up water and condensate returns to convert them into more desirable boiler feedwater.

More information

How to Trap: Steam Tracer Lines

How to Trap: Steam Tracer Lines How to Trap: Steam Tracer Lines 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing Energy Down to Earth

More information

So far 2010 is proving to be

So far 2010 is proving to be Optimising steam systems: part I Simple techniques to reduce the cost of ownership of a refinery s steam distribution system and condensate return using steam traps and separators Ian Fleming Spirax Sarco

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information