NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

Size: px
Start display at page:

Download "NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS"

Transcription

1 CI/SfB (57) Uniclass L753 November 2007 NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

2

3 CONTENTS INTRODUCTION 4-5 Passivent systems, Technical context 6-8 EXTRACT VENTILATION SYSTEMS 9-10 Passive Stack Ventilation (PSV) PSV Whole-House 12 PSV Single-Stack 13 PSV Design and Installation Mechanical Extract Ventilation (MEV) Passivent MEV 18 Passivent imev 19 Passivent AV Passivent Flair Positive Input Ventilation (PIV) BACKGROUND VENTILATION Window vents Fresh wall vents ACOUSTIC VENTILATION 45 Acoustic solutions: Systems Acoustic solutions: Background ventilation COMBUSTION AIR VENTILATION COMPONENTS, SERVICES 57 Selected components Design and support, Services References

4 . PASSIVENT the..... natural and..... energy-efficient ventilation specialists Passivent Limited are the leading specialists in natural and energy-efficient mechanical extract ventilation for domestic buildings. Expertise Passivent have an unrivalled expertise in designing and developing ventilation solutions to meet the most up-to-date technical and regulatory requirements. Immense experience During the last 15 years over Passivent systems have been installed in the UK alone, giving efficient and effective ventilation at all times. There is also a vast range of experience with Passivent systems over many years in Europe. Technical and design capability We can provide authoritative technical support, advice and design services. Comprehensive range The Passivent range provides ventilation systems and products tailored to all types of domestic applications. Energy-efficient Passivent systems are extremely energyefficient, typically providing higher energy ratings than other forms of ventilation. They offer many advantages over other, non-responsive, systems. Building regulations compliance Passivent systems can be used to meet building regulations requirements throughout the UK and Ireland. Innovation We are constantly developing our ventilation systems and components to meet new requirements and further improve performance. Quality assurance All Passivent systems and components have been designed, developed and manufactured under a BS EN ISO 9001 Quality Management System. Independent auditing provides the user with assurance that the products will fulfil their intended purpose

5 PASSIVENT SYSTEMS OVERVIEW Passivent offer a range of passive and mechanical extract ventilation systems which meet the requirements for dwellings set out in Building Regulations Approved Document F (England and Wales), and similar requirements for the whole of the UK and the Republic of Ireland. For more details of Building Regulations requirements see page 8. Passivent BBA Certificated PSV and MEV Whole-House systems provide the required functions of: - extract ventilation to remove pollutants, and - whole building (background) ventilation to provide a supply of fresh air These systems have major advantages over ventilation based on individual extract fans. Passivent window/wall ventilators can provide whole-building (background) ventilation for Intermittent Fan (System1) and Continuous Mechanical Extract (System 3) systems by others. Positive Input Ventilation (PIV) is an alternative strategy which is acceptable under Approved Document F provided compliance can be demonstrated

6 NATURAL AND ENERGY-EFFICIENT VENTILATION FOR DOMESTIC BUILDINGS PASSIVENT SYSTEMS Passive Stack Ventilation (PSV) see pages (Approved Document F System 2) Applications: Main features: Public and private housing, primarily for individual houses and flats. New-build, major refurbishment Continuous demand controlled ventilation, silent operation, no energy consumed Mechanical Extract Ventilation (MEV) see pages (Approved Document F System 3) Applications: Main features: Public and private housing. Houses, flats, multi-occupancy buildings such as nursing homes, student accommodation, hotels. New-build, major or minor refurbishment Single central fan connected to multiple extracts, continuous low-level ventilation, quiet operation Positive Input Ventilation (PIV) see pages (Approved Document F paragraph 0.15) Applications: Main features: Public and private housing. Houses, flats. Major or minor refurbishment Ductless system, easy to install. Background Ventilation see pages (Approved Document F Systems 1, 2 and 3) Applications: Main features: Public and private housing. Houses, flats, multioccupancy buildings such as nursing homes, student accommodation, hotels. Major or minor refurbishment Large range of controllable window and throughwall vents. Acoustic Ventilation see pages (Approved Document F Systems 1, 2 and 3) Applications: Main features: All types of housing in areas of high noise levels PSV, MEV and background ventilation with acoustic treatment for sound reduction

7 NATURAL AND ENERGY-EFFICIENT VENTILATION FOR DOMESTIC BUILDINGS TECHNICAL CONTEXT Why ventilate Ventilation is essential in all buildings for the well-being and health of the occupants to: Provide a supply of fresh air for persons using the building, creating a comfortable environment. Extract moisture at source from areas where it is produced in significant quantities (eg kitchens and bathrooms), thereby combating condensation. Dilute and remove pollutants including dust mites, tobacco smoke and cleaning chemicals, promoting a healthier air quality. Aid the removal of occasional high concentrations of pollutants and water vapour. Ventilation may also be used to improve thermal comfort and reduce overheating of buildings in summer. Energy savings Buildings are being made more and more airtight, driven by government regulations to save energy and reduce carbon emissions. Previous fortuitous ventilation routes (by natural infiltration) are being sealed, increasing the importance of an effective ventilation strategy. The need to reduce energy consumption and combat climate change means that energy savings must be made in buildings. It is therefore vital to select an effective and energy-efficient method of ventilation. Passivent systems are proven to be among the most energy-efficient. Energy efficiency and SAP Government action in response to climate change is driving the demand for increased energy efficiency. By 2016 the Government wants all new dwellings built to be zerocarbon. As part of building regulations improvements, all new housing has to be energy rated; this is achieved through the Standard Assessment Procedure (SAP). Passivent PSV with no electrical consumption and automatic operation is naturally energy-efficient. To allow flexibility and encourage innovation, energy-efficient systems can be independently tested and their actual performance used in the SAP through the Appendix Q route instead of the SAP default value. The use of energy-efficient DC fans in all Passivent MEV systems makes them more energy efficient than the SAP MEV default value. Health benefits Proper ventilation of buildings has been shown to help reduce the incidence of asthma and other allergy related problems. Controlled ventilation Traditional buildings had a considerable amount of accidental ventilation through air infiltration. In order to reduce energy loss, modern buildings (and refurbished buildings) are increasingly required to meet standards for reduced air leakage. By itself, this would lead to problems arising from lack of ventilation. A ventilation strategy is therefore required to provide good indoor air quality whilst minimising energy loss through unintended air leakage. The concept of 'build tight - ventilate right' means: - Minimising the amount of accidental and uncontrolled air leakage through the building envelope - Providing controlled ventilation to supply the required level of fresh air and expel moisture vapour and other air pollutants. In other words, ventilation where and when it is needed

8 NATURAL AND ENERGY-EFFICIENT VENTILATION FOR DOMESTIC BUILDINGS TECHNICAL CONTEXT Ventilation design A designed ventilation strategy should make use of the following elements: Extract ventilation from 'wet' rooms including kitchens, bathrooms, utility rooms and WCs, to remove water vapour, together with other pollutants, directly from the rooms where it is mostly generated. Whole building ventilation to provide a supply of fresh air from outside. This also has the function of diluting and dispersing pollutants wherever they are generated within the building. Purge ventilation to remove high concentrations of pollutants generated by occasional activities such as painting and decorating. Building Regulations requirements The basic requirement of regulations is that there should be adequate means of ventilation for the occupants of a building. Requirements, and detailed means of satisfying them, are given in the documents listed below. Passivent Technical Services Team can also provide advice and guidance on ventilation and regulatory compliance. England and Wales Approved Document F Means of ventilation (2006). For guidance, please refer to: Scotland Building (Scotland) Regulations 2004, Technical Handbook Domestic Section 3 Environment (2007). Northern Ireland Building Regulations (Northern Ireland) Technical Booklet K Ventilation (1998). Republic of Ireland Building Regulations Technical Guidance Documents, Part F Ventilation (2002). Associated regulations The building regulations for energy conservation also require control of air leakage rates through the building fabric (England and Wales Part L) and provision of an air supply for fuel-burning appliances (combustion air, England and Wales Part J)

9 EXTRACT VENTILATION SYSTEMS Passive Stack Ventilation (PSV) PSV Whole-House 12 PSV Single-Stack 13 Mechanical Extract Ventilation (MEV) Passivent MEV 18 Passivent imev 19 Passivent AV Passivent Flair Positive Input Ventilation (PIV)

10 EXTRACT VENTILATION SYSTEMS PASSIVENT SYSTEMS Passivent have ventilation systems tailored for all types of domestic applications and to meet the requirements of building regulations. Passive Stack Ventilation (PSV) see pages (System 2) Applications: Public and private housing, primarily for individual houses and flats. New-build, major refurbishment Main features: Continuous demand controlled ventilation, silent operation, no energy consumed Mechanical Extract Ventilation (MEV) see pages (System 3) Applications: Public and private housing. Houses, flats, multi-occupancy buildings such as nursing homes, student accommodation, hotels. New-build, major or minor refurbishment Main features: Single central fan connected to multiple extracts, continuous low-level ventilation, quiet operation Positive Input Ventilation (PIV) see pages Applications: Public and private housing. Houses, flats. Major or minor refurbishment Main features: Ductless system, easy to install

11 EXTRACT VENTILATION SYSTEMS PASSIVE STACK VENTILATION (PSV) PASSIVE STACK VENTILATION (PSV) System 2 The PSV principle Passive stack ventilation (PSV) is driven primarily by the natural stack or convection effect by which warm air rises. Moisture-laden air is extracted directly from wet rooms (kitchens, bathrooms etc) through ducting up to a roof terminal where it is vented to the outside. The air inside a house is almost always warmer than that outside, and so rises up the duct by natural convection, carrying moisture with it. Wind blowing across the roof provides additional suction (the venturi effect). Colder air outside Moisture-laden warm air rises up duct and is exhausted through roof terminal Warm moist air inside

12 EXTRACT VENTILATION SYSTEMS PASSIVE STACK VENTILATION (PSV) PSV WHOLE-HOUSE A PSV Whole-House system ventilates all the rooms in a property effectively, using the concept of planned air routes to ensure a fresh healthy environment. Planned air routes Moisture is extracted at source from wet rooms (kitchens, bathrooms etc). Air inlets located in dry rooms (living rooms, bedrooms etc) provide a flow of replacement fresh air into the building. The siting of the inlets and extracts ensures that air always moves from dry rooms to wet rooms, so that moisture is removed and the whole house is ventilated. Applications Suitable for both new-build and refurbishment in private and social housing. Primarily designed for individual houses and low-rise flats and apartments. Demand control Ventilation is controlled by intelligent inlets and extracts which respond automatically to changes in relative humidity, thereby modulating the ventilation rate in each room to meet demand. When humidity is low the ventilation rate is minimised, irrespective of external weather conditions, preventing unnecessary heat loss. Both inlets and extracts are operated by a set of nylon strands which respond to humidity levels and regulate the size of the air opening, giving greater ventilation when humidity is high whilst preventing unnecessary ventilation when humidity is low. Features and benefits Natural and energy-efficient No electrical connection or power source is required, so Passivent PSV systems are naturally energy-efficient. Continuous operation The system provides 24-hour condensation control with continuous gentle extraction. It operates all day and every day as required, combating condensation and mould growth. Reduces requirement for background ventilation Using PSV means fewer tricklevents or wall vents are required, when compared to using intermittent fans. No noise Passivent PSV systems are completely silent in operation. Ideal for special needs With its automatic response and no operating controls, Passivent PSV is ideal for special-needs applications. Minimal maintenance No mechanical components to go wrong. BBA approved Passivent PSV Whole-House systems are covered by BBA (British Board of Agrément) Certificate No 96/3273. Design service Passivent Limited offers a design service for PSV systems, see over. Typical PSV Whole-House ventilation system All air inlets and extracts respond automatically to relative humidity in rooms. Air movement is from dry to wet rooms. Building regulations Passivent systems can be used to satisfy building regulations requirements throughout the UK and the Republic of Ireland for extract and whole-house ventilation for domestic and domestic-type properties See also the general introduction page 8. More information is available on request. Passivent systems also meet the regulatory requirements for security, avoiding draughts and preventing rain ingress. Separate roof terminal for each stack Bedroom with air inlet Bathroom with air extract Living room with air inlet Kitchen with air extract

13 PSV SINGLE-STACK As a quiet alternative to an individual room extract fan, PSV Single-Stack systems can be installed to ventilate individual en-suites or bathrooms. They operate by the same natural stack effect as PSV Whole-House systems, and hence represent a superior alternative to a fan. They provide the same benefits of demand control, continuous operation and energy efficiency as PSV Whole-House systems, and are easy to install. Applications Suitable for both new-build and refurbishment in private and social housing. Particularly useful as a low-cost refurbishment installation in social housing. Typical PSV Single-Stack system Extract responds automatically to relative humidity. Roof terminal Individual or en-suite bathroom with air extract

14 EXTRACT VENTILATION SYSTEMS PASSIVE STACK VENTILATION (PSV) SYSTEM DESIGN AND INSTALLATION Design of a system for an individual property is quite simple using our online design and quotation web site at Alternatively Passivent Limited offers a design service for PSV systems, based on building drawings supplied. A full installation guide is supplied with every Passivent PSV system. Typical layout (schematic) Actual installations may differ in detail. Follow the design layout if one is provided. Terminals must be no more than 0.5 metre down from the ridge. Each duct must run to a separate terminal Ducts must rise vertically or near-vertically, preferably not more than 45 from vertical with a maximum of 2 no. bends Use insulated ducting in the roof void and other unheated spaces The main features of a typical installation with the points which must be observed are shown below. For simplicity of design and ordering, a number of standard stack kits are available. Ordering To order Passivent-designed PSV systems simply state the quotation number and plot or plots required followed by the ridge or tile manufacturer, make and colour. For selfdesigned PSV systems simply quote the stack kit reference and quantity of each required, followed by the ridge or tile manufacturer, make and colour, and the inlet type and quantity required. Support flexible ducting every 300mm to a wire or timber batten to prevent sagging System components Standard stack kits are available as shown. Where these are not suitable, alternative configurations can be supplied. Extension ducting is also available for properties over two storeys. For individual components (air inlets, terminals, ducting) see the Components section page 58. Code A161 Description Humidity-sensitive extract F12513 Uninsulated flexible ducting, 3.0m F12524 Insulated flexible ducting, 4.0m FCA3 FCA4 FCA6 FCA10 FCA11 Flat channel straight connector Flat channel circular connector Flat channel circular adaptor Flat channel elbow connector Round pipe FCD1 Flat channel ducting, 1.5m MC01 PRT TT7 TT9 Sleeve coupling, male 125mm Ridge terminal In-Line tile/slate terminal Tile terminal Speed clamp Bedroom Site air inlets in dry rooms (living rooms, bedrooms etc) Bathroom Site each air extract in a wet room (kitchen, bathroom) Within the building, run circular ducting in a room corner or inside a fitted cupboard or wardrobe. Alternatively run flat channel ducting within a stud partition Air flow from dry to wet rooms Living room Kitchen There is usually sufficient air flow around internal doors to provide replacement air. If this is insufficient a door undercut of 10mm or an air transfer door grille should be used. No electrical connections are required

15 PSV 01 Kit Typical ground floor kitchen: Flat ducting, ridge terminal. PRT F12524 FCA4 FCA6 FCD1 FCA3 FCD1 FCA6 A161 PSV 05 Kit Typical first floor bathroom: Ridge terminal. PRT F12524 A161 PSV 06 Kit Typical first floor bathroom: Tile terminal. TT9 F12524 A161 PSV 02 Kit Typical ground floor kitchen: Circular ducting, ridge terminal. PRT F12524 A161 PSV 03 Kit Typical ground floor kitchen: Circular ducting, tile terminal. MC01 F12513 PSV 07 Kit Typical ground floor kitchen: Wall extract, flat ducting, tile terminal. TT9 F12524 FCA4 FCA6 FCD1 FCA3 FCD1 FCA10 A161 FCA11 TT9 F12524 MC01 F12513 A161 PSV 08 Kit Typical ground floor kitchen: Flat ducting, tile terminal. TT9 F12524 FCA4 FCA6 FCD1 FCA3 FCD1 FCA6 A161 PSV 04 Kit Typical ground floor kitchen: Wall extract, flat ducting, ridge terminal. PRT F12524 FCA4 FCA6 FCD1 FCA3 FCD1 FCA10 A161 PSV 09 Kit FCA11 Typical first floor bathroom: In-Line tile/slate terminal. Not suitable for kitchens. TT7 F12524 A161 Specification clause Select options required, and insert information where necessary. Passivent PSV Whole- House ventilation system Provide a BBA-Certificated ventilation system complying with Building Regulations (England and Wales) Approved Document F OR Building (Scotland) Regulations Technical Handbook Domestic Section 3 OR Building Regulations (Northern Ireland) Technical Booklet K OR Building Regulations (Republic of Ireland) Technical Guidance Documents Part F, by means of a whole-house passive stack ventilation (PSV) automatic system comprising: Humidity-sensitive wall/window inlet vents operating between 47% and 65% relative humidity, sited in habitable rooms as required. Humiditysensitive ceiling extracts operating between 30% and 75% relative humidity sited in kitchen, bathroom, utility room and WC; each extract to be ducted separately to a roof terminal matching and forming an integral part of the ridge, or to pitched roof tile/slate terminals sited no lower than 0.5 metres down from the ridge. Ridge terminals to have an air flow resistance not exceeding 10Pa at an air movement rate of 100m 2 /h. Tile/slate terminals to have an air flow resistance not exceeding 5Pa at an air movement rate of 100m 2 /h. All terminals to provide insect and weather protection, and be designed to ensure any condensate forming will run off on to the roof. All ducting in roof spaces and other unheated spaces to be fully insulated with 25mm insulation. The system to be Passivent PSV Whole-House system covered by BBA Certificate 96/3273, supplied by Passivent Limited, 2 Brooklands Road, Sale, Cheshire M33 3SS. Telephone: , fax: , info@passivent.com. Installation to be in accordance with the manufacturer s instructions, and to be carried out by a Passivent Mastercare trained installer holding a current certificate. Layout and installation must comply with any design recommendations supplied

16 EXTRACT VENTILATION SYSTEMS MECHANICAL EXTRACT VENTILATION (MEV) MECHANICAL EXTRACT VENTILATION (MEV) System 3 Passivent MEV systems Passivent Mechanical Extract Ventilation (MEV) systems provide continuous mechanical extraction at a low rate, boostable (manually or automatically) to extract at a higher rate when required. Whole-house systems comprise a remotely located central extract fan connected by ducting to extracts in wet rooms (kitchen, bathrooms etc), with air inlets located in dry rooms only (eg living rooms, dining rooms, bedrooms). Planned air paths Moisture is extracted at source from wet rooms. Air inlets located in dry rooms provide a flow of replacement fresh air into the building. The siting of the inlets and extracts ensures that air always moves from dry rooms to wet rooms, so that moisture and other pollutants are removed at source and the whole building is ventilated. MEV Systems Passivent has a range of MEV systems which can be matched to the intended application. Passivent MEV Continuous extract system with boost, automatic or manual, provided by extracts. Primarily individual systems for houses and apartments. Passivent imev Continuous extract system with boost provided by automatic humidity-sensitive control of fan speed and extracts. Provides individual room control automatically. Passivent AV Continuous extract system with boost, automatic or manual, provided by extracts. Primarily multiple systems for apartments and multi-occupancy applications. Passivent Flair Continuous extract system for new-build apartments, integrating the latest design in cooker hoods. Air is exhausted through roof (or wall) terminals Low-power continuouslyrunning central extract fan located in loft space (or cupboard) Air extracts located in wet rooms Extract ducts may serve a number of rooms

17 Applications MEV systems are suitable for a wide range of applications including houses, apartments and multi-occupancy buildings such as nursing homes, student accommodation and hotels. In flats and apartments MEV systems can be designed to ventilate either an individual apartment or several apartments simultaneously. Systems are suitable for both new build and refurbishment. Features and benefits Tailored systems The range of extracts enables systems to be tailored specifically to suit individual room applications. Demand control Humidity-sensitive system, with automatic boost to meet greater demand when required, provides greater comfort and energy efficiency. Planned air movement The positions of inlets and extracts ensure that air always moves from dry rooms to wet rooms, where it is extracted. Continuous extraction with boost Continuous gentle extraction at all times; the system operates all day and every day, boosting as required. No noise problems The fan is normally installed in the roof space or a cupboard to avoid noise problems. Ideal for special needs Automatic imev option ideal for special needs, with no manual control required. Energy-efficient, low maintenance Fans have a low energy consumption, and minimal maintenance is required. Simple installation Requirement for background ventilation (air inlets) is significantly reduced compared with intermittent extract fans. Design service Passivent Limited offer a design service for MEV systems. Building Regulations and energy performance The Government s Standard Assessment Procedure (SAP) is the method for calculating the energy rating or performance of dwellings to comply with Building Regulations. Registered SAP assessors use a computer program to calculate - the SAP rating - the Target CO 2 Emission Rate (TER) based on standard values for a dwelling of the same size and shape, and - the Dwelling CO 2 Emission Rate (DER), based on the performance values for the actual dwelling being assessed. For compliance, the DER must be no worse than the TER. Appendix Q of the SAP allows the use of actual performance data derived from independent assessments of systems, in place of default values. For energy efficient systems such as Passivent MEV this method can provide an enhanced SAP rating. The A151DC fan used in the Passivent MEV system is included on the Appendix Q web site. System design Passivent offer a design service for our MEV systems, based on building drawings supplied. Initially an outline proposal and estimate for a system will be prepared; following acceptance of this, a full design and costing will be prepared. System installation A full installation guide is supplied with each mechanical extract ventilation system

18 EXTRACT VENTILATION SYSTEMS PASSIVENT MEV Description Extraction is driven by a single low-power consumption DC fan. This is normally installed in the roof space or a cupboard and mounted to avoid noise disturbance. Fans operate efficiently at all times whether vents are fully open or virtually closed. Extraction can be boosted by a control switch, which shows the user via an LED display, the level at which the fan is operating. BBA approved Passivent MEV Whole-House systems are covered by BBA (British Board of Agrément) Certificate No 96/3273. System components Extract fan A151DC Low-wattage DC continuously-running fan, specially designed for efficient extraction of air along lengthy ducts. Extract A125 extracts located in wet rooms. Other components For air inlets, terminals, and ducting, see the Components section on page 58. System installation A full installation guide is supplied with each system. Typical MEV Whole-House ventilation systems Air movement is from dry to wet rooms Individual house Apartments: individual systems Extract fan Extract fan Bathroom Extract fan Kitchen Bathroom Kitchen Kitchen Bathroom

19 EXTRACT VENTILATION SYSTEMS PASSIVENT imev Description Innovative and intelligent, imev is a totally new concept in central mechanical extract ventilation. The system automatically provides, without any occupant involvement, individual room control, and is eminently suitable for both houses and apartments. The low-energy DC central extract fan incorporates a humidity sensor linked to a microprocessor that continuously monitors the relative humidity of the extracted air. The fan is linked via ducting to humidity responsive extracts located in the wet rooms. These open and close in response to relative humidity. Sensing increasing humidity the processor will progressively boost the fan. Therefore when relative humidity increases in that room: 1. the extract in that room will open 2. the humidity of the exhaust air will increase 3. the fan speed will increase 4. thus boosting the extract rate from the room containing the open extract. As humidity is reduced the extract will close and the fan will slow down to its normal running setting, until relative humidity in a wet room increases again. System components Extract fan A151DCH Low energy central extract fan containing integral humidity sensor and microprocessor. Progressively boosts extract rate in response to increasing levels of relative humidity in the extracted air. Extracts A121 humidity sensitive extracts located in wet rooms respond automatically to changes in relative humidity, opening and closing to meet demand, working in harmony with the fan to boost individual room extraction. Other components For air inlets, terminals, and ducting, see the Components section on page 58. System installation A full installation guide is supplied with each system. Typical imev Whole-House ventilation systems Individual house Apartments: individual systems Extract fan Extract fan Bathroom Kitchen Bathroom Extract fan Kitchen Kitchen Bathroom

20 EXTRACT VENTILATION SYSTEMS PASSIVENT AV Description Extraction ventilation is driven by a continuously-running central DC extract fan connected to extracts located in the wet rooms. Ventilation is boosted by the wider opening of the extracts, which can provide either automatic or manual boosts. Passivent AV is eminently suitable for apartments, where a single system can ventilate several apartments, and for student accommodation, hotels and care and nursing homes. Typical AV Whole-House ventilation systems Apartments: multiple system Extract fan Kitchen Bathroom 20 The system is specially designed for efficient extraction of low volumes of air along lengthy ducts. The use of one system for several dwellings can reduce running costs and energy consumption per dwelling. It also minimises the number of roof penetrations required. BBA approved Passivent AV Whole-House systems are covered by BBA (British Board of Agrément) Certificate No 96/3273. System components Extract fan A151DC Low-wattage DC central extract fan for efficient extraction of air along lengthy duct runs. Extracts All extracts are for ceiling or wall-mounting in wet rooms. Boost is provided by wider opening of the vents, controlled as shown below. Humidity-sensitive extracts respond to room humidity automatically. Timed electrical boost is activated manually and operates for a preset time. Constant volume extracts are selfregulating to maintain a constant extract rate. PIR (passive infrared) boost is activated when a person is detected in the room, and operates for a preset time. The range of extracts enables the whole design and ventilation strategy to be tailored to individual room requirements and use. Other components For air inlets, terminals, ducting, see the Components section page 58. Multi-occupancy: nursing homes, student accomodation, hotels etc Bedroom Bedroom Kitchen Extract fan Ensuite bathroom Ensuite bathroom Bathroom Corridor Corridor

i PSV WHOLE-HOUSE VENTILATION SYSTEM

i PSV WHOLE-HOUSE VENTILATION SYSTEM CI/SfB (57) Uniclass Ss_65_40_33_56 November 2017 i PSV WHOLE-HOUSE VENTILATION SYSTEM Humidity-sensitive wall ventilator Energy saver vent................................ HOW TRADITIONAL PASSIVE STACK

More information

VENTILATION DESIGNED FOR CARE HOMES

VENTILATION DESIGNED FOR CARE HOMES CI/SfB (57) Uniclass Pr_65_67_29 October 2017................................ ............................................................................. Contents Ventilation designed for Care Homes

More information

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS ...................................... CI/SfB (57) Uniclass L753 July 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS................................................................... ...................................................................................

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS...

CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS... CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS... ................................................ TRICKLE VENTILATORS..................................................................

More information

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates Creating an Energy-Chic Home The Highgate Society, 8 February 2017 No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates www.rickabythompson.com No Taxation Without Representation

More information

NATURAL VENTILATION CONTROL SYSTEMS

NATURAL VENTILATION CONTROL SYSTEMS ...... CI/SfB (57.9) Uniclass L755 September 2005 NATURAL VENTILATION CONTROL SYSTEMS... . 2 ...... Passivent ventilation control systems have been have been specially developed to meet the requirements

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

ACTIVE VENTILATION SYSTEMS

ACTIVE VENTILATION SYSTEMS ...................................... CI/SfB (57) Uniclass L75 June 2013 Contents Passivent Active Ventilation 3 The need for ventilation 4 What is Active Ventilation? 5 Active Transfer - Atrium System

More information

Technical Bulletin 005(B) Developed with Building Standards Scotland

Technical Bulletin 005(B) Developed with Building Standards Scotland Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version

More information

Building Regulations Approved Document F1 Means of Ventilation April 2006

Building Regulations Approved Document F1 Means of Ventilation April 2006 Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat

More information

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and

More information

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy

More information

Building Regulations 2010: What it means to you.

Building Regulations 2010: What it means to you. Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both

More information

Condensation Control in New Homes. Important information for owners and occupiers

Condensation Control in New Homes. Important information for owners and occupiers Condensation Control in New Homes Important information for owners and occupiers CONDENSATION CONTROL IN NEW HOMES A newly-built home contains more moisture than one which has been lived in for a time.

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS CI/SfB (57) Uniclass Ss_75_70_52_94 July 2017 INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS................................ 2...................................................................

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS

INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS ...................................... CI/SfB (57) Uniclass L751 September 2012................. FURTHER.............. INFORMATION........... INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS

More information

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

LANDLORDS & LETTINGS VENTILATION SOLUTIONS LANDLORDS & LETTINGS VENTILATION SOLUTIONS CREATING A HEALTHY INDOOR ENVIRONMENT CONTENTS INTRODUCTION... 3 WHY IS VENTILATION IMPORTANT?...4 CURE CONDENSATION FOR GOOD... 5 THE DRIMASTER RANGE... 6 SINGLE

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

HYBRID PLUS2 AIRCOOL VENTILATORS

HYBRID PLUS2 AIRCOOL VENTILATORS NEW PRODUCT CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 February 2018 HYBRID PLUS2 AIRCOOL VENTILATORS................................ ........................................................ HYBRID PLUS2

More information

Energy Efficient Air Distribution Systems

Energy Efficient Air Distribution Systems (57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation

More information

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION 2 ND EDITION 1 Contents 1. Purpose of this document 3 Page 2. Ventilation 4 3. Purpose provided ventilation 6 4. Natural ventilation- windows,

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation Heat Recovery Ventilation (HRV) is an integral part of the Passive House approach to achieving ultra-low energy houses. In the UK, HRV

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition By Appointment to H.M. The Queen Suppliers of Unit Ventilation Equipment Vent-Axia, Crawley, West Sussex VENT-AXIA CONTACT NUMBERS Free technical, installation and sales advice

More information

VENTILATION AND HEAT RECOVERY

VENTILATION AND HEAT RECOVERY VENTILATION AND HEAT RECOVERY In last month s article we looked at the energy cost of ventilation. The cost of the heat lost when stale air is extracted is much greater than any energy used by fans. But

More information

Energy Efficiency Standards

Energy Efficiency Standards GENERAL INFORMATION LEAFLET 72 Energy Efficiency Standards For new and existing dwellings GENERAL INFORMATION LEAFLET 72 BEST PRACTICE PROGRAMME INTRODUCTION The Housing Energy Efficiency Best Practice

More information

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. CI/SfB (57.7) 3rd Edition WINNER2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. Lo-Carbon Centra Allowing you to help the environment

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

HYBRID PLUS2 AIRCOOL VENTILATORS

HYBRID PLUS2 AIRCOOL VENTILATORS NEW PRODUCT CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 February 2018 HYBRID PLUS2 AIRCOOL VENTILATORS................................ ........................................................ HYBRID PLUS2

More information

The Glidevale range of Fresh wall

The Glidevale range of Fresh wall CI/SfB (57) Uniclass Pr_30_59_96 December 2017 The Glidevale range of Fresh wall ventilators has been specially designed to introduce fresh air into our homes in order to control condensation, and being

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Polypipe Ventilation Specifiers Guide

Polypipe Ventilation Specifiers Guide Uniclass L75344 CI/SfB (57.5) X PVSB-2 May 215 Polypipe Ventilation Specifiers Guide Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Intermittent Extract and Decentralised Mechanical

More information

FRESHVENT. Select a product. Home/Freshvent

FRESHVENT. Select a product. Home/Freshvent Home/Freshvent FRESHVENT Completely silent, all year round ventilation Complements existing ventilating fans Filtered, natural air without draughts Control of the indoor environment Helps prevent damaging

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS Nuaire Ltd Broomhouse Lane, Edlington, Doncaster, South Yorkshire DN12 1ES Tel: 029 2085 8200 Fax: 029 2085 8300 Agrément Certificate e-mail: info@nuaire.co.uk 00/3727 website: www.nuaire.co.uk Product

More information

DEMAND-CONTROLLED HOME VENTILATION

DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously A good indoor climate is all about health and

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN? AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN? In its simplest form, an air curtain is a continuous broad stream of air circulated across a doorway serving a conditioned space. Air curtains are normally mounted

More information

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary... 5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS 3.18.6 Independent Control of Two Space and One Water Heating Circulation Zones in a Fully Pumped System with Three Motorised Valves... 64 3.19 Non Domestic Systems and Processes... 64 SECTION 4 FUEL CONSERVATION

More information

Short Form Ventilation Product Guide

Short Form Ventilation Product Guide Uniclass L7534 CI/SfB (57) X FVSF-2 May 2015 Short Form Ventilation Product Guide FERROB VENTILATION design, manufacture and install specialist domestic and light commercial ventilation products for landlords,

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

DUCTING FOR HRV SYSTEMS The distribution of airflows

DUCTING FOR HRV SYSTEMS The distribution of airflows DUCTING FOR HRV SYSTEMS The distribution of airflows As we saw in my two previous articles, Heat Recovery Ventilation (HRV) gives healthy and comfortable ventilation whatever the weather. And in wintertime,

More information

Condensation in your Property. A Homeowners guide to. A guide to the causes and how to remedy the problem

Condensation in your Property. A Homeowners guide to. A guide to the causes and how to remedy the problem A S S O C I A T I O N A Homeowners guide to Condensation in your Property A guide to the causes and how to remedy the problem 0844 375 4301 www.property-care.org Condensation in your home is your home

More information

Kills bills. How Vaillant technologies reduce home heating bills

Kills bills. How Vaillant technologies reduce home heating bills Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,

More information

Lossnay RVX Fresh Series Air Ventilation

Lossnay RVX Fresh Series Air Ventilation Lossnay RVX Fresh Series Air Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould,

More information

Ventilation Product range ADVANCE ECO 4 ECO 2

Ventilation Product range ADVANCE ECO 4 ECO 2 Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System Best Practice Guidance Best Practice Guidance Positive Input Ventilation (PIV) System October 2017 1. INTRODUCTION 2. DEFINITIONS 3. CONCEPT AND BACKGROUND OF PIV 4. INSPECTION CONSIDERATIONS 5. OCCUPIER

More information

2013 innovation. Room-by-room demand controlled heat recovery ventilation

2013 innovation. Room-by-room demand controlled heat recovery ventilation 2013 innovation Room-by-room demand controlled heat recovery ventilation 2 Revolution in the world of heat recovery ventilation Through its new ventilation system, which combines heat recovery and room-by-room

More information

SMOKE CONTROL - NEW DIRECTIONS

SMOKE CONTROL - NEW DIRECTIONS SMOKE CONTROL - NEW DIRECTIONS Nuaire provides the total package for smoke control with schemes designed to fully comply with statutory and regulatory requirements. Our team of skilled engineers include

More information

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation

More information

Vireo Fresh intelligence

Vireo Fresh intelligence Vireo Fresh intelligence www.fresh-intelligence.co.uk Heat Recovery Ventilation Vireo Fresh intelligence Vireo: An elegant white good designed for all types of new homes. Heat Recovery Ventilation with

More information

Air Flow Solutions. A Guide to Specifing and Installing Residential Ventilation

Air Flow Solutions. A Guide to Specifing and Installing Residential Ventilation Air Flow Solutions A Guide to Specifing and Installing Residential Ventilation Contents Section 1: Why we need to ventilate 4-5 Airtight Homes Condensation Carbon Emissions Mould Toxic Gases Noise Concept

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

ventilation solutions

ventilation solutions ventilation solutions for apartments and communal residences Helping to create a relaxing, ventilation solutions comfortable environment Nuaire is the market leader in the design and manufacture of energy

More information

Energy Efficiency in New Housing

Energy Efficiency in New Housing Energy Efficiency Best Practice in Housing Energy Efficiency in New Housing Summary of Specifications for England, Wales and Scotland how to achieve the best in energy efficiency in new housing measures

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air Heating and Cooling Ceiling Systems Comfortable and energy efficient Heating Cooling Fresh Air Clean Air Comfortable and energy saving. Compromises are often needed when a building needs to be heated or

More information

An introduction to Part L insulating pipes and ducts

An introduction to Part L insulating pipes and ducts October 2010 An introduction to Part L insulating pipes and ducts The insulation of pipes and ducts is essential to minimise heat losses for heated systems and heat gains for cooled systems. For cooled

More information

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit Titon CME1 Q Plus Mechanical Extract Ventilation Unit Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents This is the Product Manual for the Titon CME1 Q Plus Introduction...................................

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web:  Why use Underfloor Heating? UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating (UFH) is not a new concept; it was brought to Britain about 2,000 years ago by the Romans. Their heating technique was to allow hot gasses from

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

Itho CVE ECO 2 RFT. Installer/User manual

Itho CVE ECO 2 RFT. Installer/User manual Itho CVE ECO 2 RFT Installer/User manual Safety Warning - Do not use this appliance for functions other than those described in the booklet - After removing the appliance from its packaging, ensure that

More information

Background ventilators for dwellings

Background ventilators for dwellings Background ventilators for dwellings IP 2/03 information paper D I Ross, R K Stephen and J B M Pierce BRE Environment Trickle vents in window frames and airbricks in walls have been used to ventilate dwellings

More information

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS INNOVATION THAT EXCELS IN AIR QUALITY AND ENERGY SAVINGS Aereco demand controlled ventilation Combining indoor air quality

More information

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE 1 Advance Plus, ECO 4 & ECO 2. Mechanical ventilation and heat recovery systems for your home. Mechanical ventilation and heat recovery systems provide

More information

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS Issue 7 ACS.SMB 1 CCLP1 PD INITIAL & RE-ASSESSMENT Introduction Tests gas safety competence in core domestic

More information

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you

More information